Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator test facility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

A new scintillation hodoscope for CLAS12 and partial wave analysis of the channel yp → pK + K -

This thesis consists of two parts that have contributed to a new meson spectroscopy program, MesonEx, which is currently taking place in Hall B of the upgraded Thomas Jefferson National Accelerator Facility (JLab) in the USA. The first, hardware part, presents design, testing, construction and calibration of a fast-timing scintillation Hodoscope for a new Forward Tagger detector, that has been installed inside the upgraded CEBAF Large Acceptance Spectrometer (CLAS12) which is situated in the Hall B of JLab. The Forward Tagger is a key apparatus for measurement of quasi-real photoproduction of mesons in the MesonEx, and a necessary device for other new hadron spectroscopy programs. The second, software and analysis part, presents contributions to the general HAdron SPEctroscopy CenTre (HASPECT) analysis framework, that has been developed in preparation for the MesonEx data analysis. The software contribution consists of finalizing HASPECT simulation and analysis chains in a model-independent way, and developing a mass-independent partial wave analysis procedure. This procedure has been tested via analysis of the γ p → pK + K - channel from the g 11 a CLAS data, in the photon energy range E γ = 3.0-3.8 GeV and momentum transfer squared range -t = 0.6 - 0.7 (GeV/c 2 ) 2 . The first result of this analysis is the differential cross section for the ϕ(1020) resonance photoproduction. This result has been compared with a previous analysis result, and a good agreement has validated the developed analysis procedure. Furthermore, S , P and D partial waves have been extracted from the data set, using the same procedure, and ambiguous solutions for these partial waves have been calculated, using the method of Barrelet zeros which is for the first time applied to photoproduction of the K + and K - mesons on the proton. Distributions of the calculated solutions have been compared with the fit results. It is found that the physical solution contains contributions of the ϕ(1020) in the P -wave and the a 2(1320) in the D -wave.

Stankovic, Ivana↗

DARHT Axis 1 Performance Results with and without a Blumlein Charge Unit

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using two electron Linear Induction Accelerators (LIA’s). Axis 1 of DARHT produces a 20- MeV, 2-kA, 80-ns-FWHM electron beam. As DARHT Axis 1 enters its twentieth year of operation, the probability of Blumlein Charge Unit (BCU) failure has increased and the risk of a failure on the day of an explosive experiment has become more likely. Replacement time for a BCU is four to six hours. This report examines the radiographic and beam transport effect of operating the accelerator with a missing or reduced charge voltage BCU. The results are compared with normal, full machine operation. A prescription for alternate operation with missing or reduced charge voltage on BCU22 is given.

47 OTHER INSTRUMENTATION↗

Optimization of DARHT Axis 1 Injector Voltage

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using two electron Linear Induction Accelerators (LIA’s). Axis-1 of DARHT produces a 20- MeV, 2-kA, 80-ns-FWHM electron beam. The strict requirements for flash radiography require a detailed understanding of the LIA’s performance, including precision measurements of the injector electron beam energy. The technique for time resolved measurement of the electron beam energy using electron Permanent Magnet Spectrometer (ePMSpec) has been developed. The electron energy then is used to infer the voltage produced by the injector pulsed power. The injector pulsed power of DARHT I consists of a 1.5-MV, glycol-insulated Blumlein that is pulsecharged by a step-up transformer and switched by four, laser-triggered spark gaps. A series of increasing impedance transmission lines are used to transform the output voltage of the Blumlein to a maximum of 3.8MV at the diode. Figure 1a shows a graphic of the Axis-1 prime power tank, Blumlein and downstream transmission lines. The injector pulse power is designed to produce voltage on a velvet cathode located in the vacuum vessel. The specifications of the voltage-pulse flat-top over 60ns is +/-1%. A key element in the high-voltage circuit is the ethylene glycol Blumlein. The outer volume, adjacent to the laser triggered switches of the Blumlein, is a peaking capacitor. This is an independent volume that contains a mixture of ethylene glycol and water to make it an adjustable capacitor of 380 to 750 pF.

43 PARTICLE ACCELERATORS↗

Re-Analysis of DARHT Axis 2 S4 Magnet Sweep Measurements

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using two electron Linear Induction Accelerators (LIA’s). Understanding fundamental properties of the electron beams is essential to optimizing spot size and dose for radiography. This work describes distribution measurements of a single-kicked electron beam (16.5MeV, 1.7kA, 60ns) at a location downstream at imaging station C on DARHT Axis 2. The beam at station C is focused by the S4 solenoid located upstream. The beam distribution is measured by imaging optical transition radiation (OTR) from electrons striking a 51-µm thick titanium foil. This data and analysis were originally published by Ekdahl. The results here are a re-analysis of the asymmetric halo emittance contribution as compared to the emittance resulting from the FWHM of the distribution. This is accomplished using xtr2 fits to the data which include non-linear magnetic field effects in S4. Also examined are the calculated S4 spherical aberration contributions to the emittance using xtr.

43 PARTICLE ACCELERATORS↗

Effects of space environment on composites: An analytical study of critical experimental parameters

A generalized methodology currently employed at JPL, was used to develop an analytical model for effects of high-energy electrons and interactions between electron and ultraviolet effects. Chemical kinetic concepts were applied in defining quantifiable parameters; the need for determining short-lived transient species and their concentration was demonstrated. The results demonstrates a systematic and cost-effective means of addressing the issues and show qualitative and quantitative, applicable relationships between space radiation and simulation parameters. An equally important result is identification of critical initial experiments necessary to further clarify the relationships. Topics discussed include facility and test design; rastered vs. diffuse continuous e-beam; valid acceleration level; simultaneous vs. sequential exposure to different types of radiation; and interruption of test continuity.

Gupta, A.↗

Ignition of steel alloys by impact of low-velocity iron/inert particles in gaseous oxygen

The ignition of carbon steel and 316 and 304 stainless steels caused by the impact of low-velocity particles (a standard mixture consisting of 2 g of iron and 3 g of inert materials) in gaseous oxygen was investigated using NASA/White Sands Test Facility for the ignition test, and a subsonic particle impact chamber to accelerate the particles that were injected into flowing oxygen upstream of the target specimen. It was found that the oxygen velocities required to ignite the three alloys were the same as that required to ignite the particle mixture. Ignition occurred at oxygen velocities greater than 45 m/sec at 20 to 24 MPa and was found to be independent of pressure between 2 and 30 MPa. Comparison of the present results and the past results from Wegener (1964) with the Compressed Gas Association (CGA) oxygen velocity limits for safe operations indicates that the CGA limits may be excessively conservative at high pressures and too liberal at low pressures.

Benz, Frank J.↗

Suited Occupant Injury Potential During Dynamic Spacecraft Flight Phases

In support of the Constellation Space Suit Element [CSSE], a new space-suit architecture will be created for support of Launch, Entry, Abort, Microgravity Extra- Vehicular Activity [EVA], and post-landing crew operations, safety and, under emergency conditions, survival. The space suit is unique in comparison to previous launch, entry, and abort [LEA] suit architectures in that it utilizes rigid mobility elements in the scye (i.e., shoulder) and the upper arm regions. The suit architecture also utilizes rigid thigh disconnect elements to create a quick disconnect approximately located above the knee. This feature allows commonality of the lower portion of the suit (from the thigh disconnect down), making the lower legs common across two suit configurations. This suit must interface with the Orion vehicle seat subsystem, which includes seat components, lateral supports, and restraints. Due to the unique configuration of spacesuit mobility elements, combined with the need to provide occupant protection during dynamic vehicle events, risks have been identified with potential injury due to the suit characteristics described above. To address the risk concerns, a test series has been developed in coordination with the Injury Biomechanics Research Laboratory [IBRL] to evaluate the likelihood and consequences of these potential issues. Testing includes use of Anthropomorphic Test Devices [ATDs; vernacularly referred to as "crash test dummies"], Post Mortem Human Subjects [PMHS], and representative seat/suit hardware in combination with high linear acceleration events. The ensuing treatment focuses on test purpose and objectives; test hardware, facility, and setup; and preliminary results.

Dub, Mark O.↗

NASA JSC’s Simulant Development Lab Capabilities and Artemis Testing

The Simulant Development Lab (SDL) is a multifunctional collaborative workspace that supports the development, curation, analysis, testing, and distribution of planetary regolith simulants – including lunar, Martian, asteroidal, and other granular materials. The lab provides a multidisciplinary setting for scientific characterization of simulant physical properties and for engineering evaluations conducted with simulant test beds. To enable this work, the SDL curates and maintains a stock of more than 35 metric tons of simulant material. To evaluate these materials and support testing goals, the lab is equipped with a comprehensive suite of processing tools and analytical instruments. These capabilities enable the SDL’s mission at NASA’s Johnson Space Center to distribute, develop, process, characterize, and test regolith simulants for mission relevant applications. Through controlled and repeatable testing environments that replicate the physical and compositional properties of lunar regolith, the SDL supports Artemis hardware maturation, providing safe, Earth‑based analogs for evaluating systems that must withstand regolith dust interactions, physical wear and abrasion, and operational loads. The facility’s extensive simulant inventory and integrated geological and engineering test infrastructure accelerate technology readiness for Artemis and future exploration campaigns (e.g., future crewed or robotic missions to Mars).

Simulant Development Lab↗

COMMISSIONING AND FIRST RESULTS FROM CHANNELING RADIATION AT FAST

X-rays have widespread applications in science and industry, but developing a simple, compact, and high-quality X-ray source remains a challenge. Our collaboration has explored the possible use of channeling radiation driven by a 50 MeV low-emittance electron beam to produce narrowband hard X-rays with photon energy of 40 to 140 keV [8,9,11]. Here we present the simulated X-ray spectra including the background bremsstrahlung contribution, and a description of the required optimization of the relevant electron-beam parameters necessary to maximize brilliance of the resulting X-ray beam. Results are presented from our test of this, carried out at the Fermilab Accelerator Science & Technology (FAST) facility’s 50-MeV low-energy electron injector. As a result of the beam parameters, made possible by the photo-injector based SRF linac, the average brilliance at FAST was expected to be about one order of magnitude higher than that in previous experiments.

43 PARTICLE ACCELERATORS↗

Charge state breeding for the acceleration of radioactive ions at TRIUMF

A 14.5 GHz electron cyclotron resonance ion source (PHOENIX from Pantechnik) has been set up at the Isotope Separation and ACceleration (ISAC) facility at TRIUMF for the charge state breeding of radioactive ions. After extensive testing and optimization on a test bench it has been moved on-line and put into operation. During a first test in 2008 a beam of {sup 80}Rb{sup 14+} was successfully created from {sup 80}Rb{sup 1+} and accelerated by the ISAC postaccelerator. Further tests with different stable and radioactive isotopes from the ISAC on-line sources and from a test source with stable Cs have been carried out. Until now an efficiency of 1.4% for {sup 124}Cs{sup 20+} has been obtained.

43 PARTICLE ACCELERATORS↗

Dynamic Finite Element Predictions for Mars Sample Return Cellular Impact Test #4

The nonlinear finite element program MSC.Dytran was used to predict the impact pulse for (he drop test of an energy absorbing cellular structure. This pre-test simulation was performed to aid in the design of an energy absorbing concept for a highly reliable passive Earth Entry Vehicle (EEV) that will directly impact the Earth without a parachute. In addition, a goal of the simulation was to bound the acceleration pulse produced and delivered to the simulated space cargo container. EEV's are designed to return materials from asteroids, comets, or planets for laboratory analysis on Earth. The EEV concept uses an energy absorbing cellular structure designed to contain and limit the acceleration of space exploration samples during Earth impact. The spherical shaped cellular structure is composed of solid hexagonal and pentagonal foam-filled cells with hybrid graphite-epoxy/Kevlar cell walls. Space samples fit inside a smaller sphere at the enter of the EEV's cellular structure. The material models and failure criteria were varied to determine their effect on the resulting acceleration pulse. Pre-test analytical predictions using MSC.Dytran were compared with the test results obtained from impact test #4 using bungee accelerator located at the NASA Langley Research Center Impact Dynamics Research Facility. The material model used to represent the foam and the proper failure criteria for the cell walls were critical in predicting the impact loads of the cellular structure. It was determined that a FOAMI model for the foam and a 20% failure strain criteria for the cell walls gave an accurate prediction of the acceleration pulse for drop test #4.

Fasanella, Edwin L.↗

High gradient RF test results of S-band and C-band cavities for medical linear accelerators

TERA Foundation has proposed and designed hadrontherapy facilities based on novel linacs, i.e. high gradient linacs which accelerate either protons or light ions. The overall length of the linac, and therefore its cost, is almost inversely proportional to the average accelerating gradient. With the scope of studying the limiting factors for high gradient operation and to optimize the linac design, TERA, in collaboration with the CLIC Structure Development Group, has conducted a series of high gradient experiments. The main goals were to study the high gradient behavior and to evaluate the maximum gradient reached in 3 and 5.7 GHz structures to direct the design of medical accelerators based on high gradient linacs. Lastly, this paper summarizes the results of the high power tests of 3.0 and 5.7 GHz single-cell cavities.

43 PARTICLE ACCELERATORS↗

Present Status of the ILC Project and Development

The Technical Design of the International Linear Collider (ILC) Project will be finished in late 2012. The Technical Design Report (TDR) will include a description of the updated design, with a cost estimate and a project plan, and the results of research and development (R & D) done in support of the ILC. Results from directed ILC R & D are used to reduce the cost and risk associated with the ILC design. We present a summary of key challenges and show how the global R & D effort has addressed them. The most important activity has been in pursuit of very high gradient superconducting RF linac technology. There has been excellent progress toward the goal of practical industrial production of niobium sheet-metal cavities with gradient performance in excess of 35 MV/m. In addition, three purpose-built beam test facilities have been constructed and used to study and demonstrate high current linac performance, electron-cloud beam dynamics and precision beam control. The report also includes a summary of component design studies and conventional facilities cost optimization design studies.

43 PARTICLE ACCELERATORS↗

A New 2.5 MeV Injector and Beam Test Facility for the Spallation Neutron Source

The U.S. Spallation Neutron Source (SNS) now operates with 1.2 MW of beam power on target with the near-term goal of delivering 1.4 MW and a longer-term goal of delivering >2 MW to support a planned second target station. Presently, H- beam pulses (50-60 mA, 1 ms, 60 Hz) from an RF-driven, Cs-enhanced, multi-cusp ion source are first accelerated to 2.5 MeV by a Radio Frequency Quadrupole (RFQ) accelerator, injected into a ~1 GeV linac, compressed to <1μs in an accumulator ring and ultimately delivered to a liquid mercury target for pulsed neutron production. In recent years concerns about the RFQ performance has motivated the procurement of a new RFQ and the creation of a Beam Test Facility (BTF) to allow off-line testing. The purpose of the BTF is to first validate performance of the new RFQ before installing it in place of the existing RFQ and later to serve as a stand-alone 2.5 MeV research accelerator employing the original SNS RFQ. After validating the new RFQ with respect to energy, emittance and transmission, the initial applications of the BTF will be to conduct 6D beam dynamic studies, develop & demonstrate ion sources capable of meeting the current and future requirements of the SNS, and contribute to neutron moderator development. This report provides a facility update, description of the BTF ion source systems as well as a discussion of the first LEBT and RFQ beam current measurements performed at the BTF.REFERENCES

Welton, Robert F.↗

A Laser Technology Test Facility for Laser Inertial Fusion Energy (LIFE)

A LIFE laser driver needs to be designed and operated which meets the rigorous requirements of the NIF laser system while operating at high average power, and operate for a lifetime of >30 years. Ignition on NIF will serve to demonstrate laser driver functionality, operation of the Mercury laser system at LLNL demonstrates the ability of a diode-pumped solid-state laser to run at high average power, but the operational lifetime >30 yrs remains to be proven. A Laser Technology test Facility (LTF) has been designed to specifically address this issue. The LTF is a 100-Hz diode-pumped solid-state laser system intended for accelerated testing of the diodes, gain media, optics, frequency converters and final optics, providing system statistics for billion shot class tests. These statistics will be utilized for material and technology development as well as economic and reliability models for LIFE laser drivers.

42 ENGINEERING↗

Extraction simulations and emittance measurements of a Holifield Radioactive Ion Beam Facility electron beam plasma source for radioactive ion beams

The Holifield Radioactive Ion Beam Facility HRIBF at Oak Ridge National Laboratory has a variety of ion sources used to produce radioactive ion beams RIBs. Of these, the workhorse is an electron beam plasma EBP ion source. The recent addition of a second RIB injector, the Injector for Radioactive Ion Species 2 IRIS2, for the HRIBF tandem accelerator prompted new studies of the optics of the beam extraction from the EBP source. The source was modeled using SIMION V8.0, and results will be presented, including comparison of the emittances as predicted by simulation and as measured at the HRIBF offline ion source test facilities. Also presented will be the impact on phase space shape resulting from extraction optics modifications implemented at IRIS2.

43 PARTICLE ACCELERATORS↗

The Mu2e Solenoid Cold Mass Position Monitor System

The Mu2e experiment at Fermilab is designed to search for charged-lepton flavor violation by looking for muon to electron conversions in the field of the nucleus. The concept of the experiment is to generate a low momentum muon beam, stopping the muons in a target and measuring the momentum of the outgoing electrons. The implementation of this approach utilizes a complex magnetic field composed of graded solenoidal and toroidal fields. The location of the solenoid cold mass relative to external fiducials is needed for alignment as well as monitoring coil movements during cool down and magnet excitation. This study describes a novel design of a Cold Mass Position Monitor System (CMPS) that will be implemented for the Mu2e experiment.

43 PARTICLE ACCELERATORS↗

Towards 20 A negative hydrogen ion beams for up to 1 h: Achievements of the ELISE test facility (invited)

The large-scale RF-driven ion source of the test facility extraction from a large ion source experiment is aimed to deliver an accelerated ion current of 20 A D{sup −} (23 A H{sup −}) with an extracted electron-to-ion ratio below one for up to 1 h. Since the first plasma pulses for 20 s in volume operation in early 2013, followed by caesiation of the ion source, substantial progress has been achieved in extending the pulse length and the RF power. The record pulses in hydrogen are stable 400 s pulses with an extracted ion current of 18.3 A at 180 kW total RF power and 9.3 A at 80 kW stable for 1 h. For deuterium pulse, length and RF power are limited by the amount of co-extracted electrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗