Search NASA⌕ Search

SEARCH · Search NASA

Results for “acceptance sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

A large field-of-view high-resolution hard x-ray microscope using polymer optics

Here, we present an effective approach using a matched pair of polymer-based condenser-objective lenses to build a compact full-field X-ray microscope with a high spatial resolution. A unique condenser comprising arrays of high-aspect-ratio prisms with equilateral cross-section is used for uniformly illuminating samples over a large field of view (FoV) from all angles, which match the acceptance of an objective made of interdigitated orthogonal rows of one-dimensional lenses. State-of-the-art Talbot grating interferometry used to characterize these lenses for the first time revealed excellent focusing properties and minimal wave-front distortions. Using a specific lens-pair designed for 20 keV X-rays, short-exposure times, and image registration with a cross-correlation technique, we circumvent vibrational instabilities to obtain distortion-free images with a uniform resolution of 240 nm (smallest resolvable line pair) over a large FoV, 80 × 80 µm 2 in extent. The results were contrasted with those collected under illumination using commercial two-dimensional parabolic lenses with a smaller FoV. This approach implemented on a diffractometer would enable diffraction-contrast or dark-field microscopy for fast observations of ‘mesoscopic’ phenomena in real space complementing reciprocal-space studies using diffraction on the same instrument.

47 OTHER INSTRUMENTATION↗

Monitoring Uranium Transformations Determined by the Evolution of Biogeochemical Processes

Our contribution to the larger project (ANL) was the phylogenetic analysis of evolved communities capable of reducing metals including uranium. We previously reported structural shifts in microbial communities of microcosms constructed with inocula from uranium-contaminated sediment from the Field Research Center (FRC). Incubations were for up to eleven months and samples were taken from both the top and bottom of the sediment of duplicate microcosms incubated at room temperature anaerobically. The biological indices of the microcosm bacterial communities revealed that under strong selective force (e.g., sulfate and uranium) some populations became dominant and the community diversity appeared reduced. With the reduction of U(VI), bacterial community diversity appeared to recovere to its T0 level. Our clone library results revealed that some bacterial populations were persistent in the microcosms during the 11 month incubation period, while others became more abundant or less detectable in response to the prevailing environmental factors. According to the Ribosomal Database Project’s (RDP) Classifier tool, beta-Proteobacteria and Acidobacteria (e.g., Gp8) were highly abundant in the microcosms throughout the incubation period, whereas Desulfovibrio, a known sulfate-reducing Genus within which uranium reducing capabilities also reside, was substantially more abundant at early sampling times when sulfate and uranium were abundant, compared to at the end of the incubation period (11 months). We speculate that the decrease in abundance of Desulfovibrio with time was caused by consumption of sulfate and uranium during early stages of incubation. Interestingly, groups identified by the RDP as unclassified bacteria and unclassified Desulfobacteraceae responded to the selective forces differently. These two groups appeared to be more robust at the end of the incubation period when the strong initial selective force of sulfate and uranium was absent or diminished. The statistical community comparison with UniFrac indicated that early and late stage samples were evolved from the original inoculum. The RDP library comparison tool revealed that bacterial community populations shifted at statistically significant amounts according to time and space. For example, as mentioned above, early stage Desulfovibrio and Desulfobacteraceae abundances were significantly different from those where found at late incubation stage (P=0.01). Similarly, iron-oxidizing bacterium Thiobacillus was significantly more abundant at late sampling times. These results, combined with data from our colleagues were submitted to and accepted for publication in Environmental Science & Technology.

58 GEOSCIENCES↗

High speed front end of the multimegabit telemetry demodulator detector

The high speed front end (HSFE) portion of the Multimegabit Telemetry Demodulator-Detector is discussed. The HSFE accepts in-phase and quadrature analog signals from the input signal conditioner. It samples them with analog-to-digital converters at maximum rate of 64 megasamples per second. The samples are processed digitally and the integrals of I, Q, and of their crossproduct over one symbol period are supplied at symbol rate to the rest of the system.

Wechsler, E. R.↗

A study on the co- and adjacent channel protection requirements for mobile satellite ACSSB modulation

Samples of speech modulated by narrowband frequency modulation (NBFM) (cellular) and amplitude companded single sideband (ACSSB) radios were subjected to simulated co- and adjacent channel interference environments typical of proposed frequency division multiple access (FDMA) mobile satellite systems. These samples were then listened to by a group of evaluators whose subjective responses to the samples were used to produce a series of graphs showing the relationship between subjective acceptability, carrier to noise density (C/No), carrier to interference ratio (C/I), and frequency offset. The results show that in a mobile satellite environment, ACSSB deteriorates more slowly than NBFM. The co- and adjacent channel protection ratios for both modulation techniques were roughly the same, even though the mechanism for signal deterioration is different.

Sydor, John T.↗

Process Control Plan to Monitor Acceptable Levels of Flux and other residues

IPC J-STD –001G, Amendment 1 requires that the assembler have a sampling plan to assure that the process remains in control once qualified and validated. It is well documented that electrochemical failures occur at component sites where flux residues are not fully activated. It is also well known that specific components have a higher risk of electrochemical failure. Selecting a control plan that monitors the process and its performance on challenging components provides assurance that the process maintains control once established during process qualification. The test board used to qualify the process establishes an upper and lower spec limit for each of the component types on the test board. Surface Insulation Resistance upper and lower control limits, using challenging components that are representative of production hardware, represent a golden process condition. The golden image is a measure of process deviations that represents the performance of a resistance curve within a specific period. The objective is to judge whether the process in or out of control.

42 ENGINEERING↗

Identifying the secondary electron cutoff in ultraviolet photoemission spectra for work function measurements of non-ideal surfaces

Abstract Absolute values of work functions can be determined in ultraviolet photoemission spectroscopy (UPS) by measuring the minimum kinetic energy of secondary electrons generated by a known photon energy. However, some samples can produce spectra that are difficult to interpret due to additional intensity below the true secondary electron cutoff. Disordered absorbates on elemental metals add small intensity below the onset for the transition metal surfaces studied, which can be attributed to energy losses after photoelectrons are generated. In contrast, spectra from WO 3−x films can produce multiple onsets with comparable intensity which do not fit this model. False onsets (in the context of work function measurements) can be minimized by optimizing experimental detection parameters including limiting analyzer acceptance angles and pass energy. True work functions can be identified by examining the onsets as the sample bias is varied.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluation of membrane filter field monitors for microbiological air sampling

Due to area constraints encountered in assembly and testing areas of spacecraft, the membrane filter field monitor (MF) and the National Aeronautics and Space Administration-accepted Reyniers slit air sampler were compared for recovery of airborne microbial contamination. The intramural air in a microbiological laboratory area and a clean room environment used for the assembly and testing of the Apollo spacecraft was studied. A significantly higher number of microorganisms was recovered by the Reyniers sampler. A high degree of consistency between the two sampling methods was shown by a regression analysis, with a correlation coefficient of 0.93. The MF samplers detected 79% of the concentration measured by the Reyniers slit samplers. The types of microorganisms identified from both sampling methods were similar.

Fields, N. D.↗

Results for the first quarter calendar year 2017 tank 50H salt solution sample

In this memorandum, the chemical and radionuclide contaminant results from the First Quarter Calendar Year 2017 (CY17) sample of Tank 50H salt solution are presented in tabulated form. The First Quarter CY17 Tank 50H samples [a 200 mL sample obtained 6” below the surface (HTF-50-17-7) and a 1 L sample obtained 66” from the tank bottom (HTF-50-17-8)] were obtained on January 15, 2017 and received at Savannah River National Laboratory (SRNL) on January 16, 2017. Prior to obtaining the samples from Tank 50H, a single pump was run at least 4.4 hours and the samples were pulled immediately after pump shut down. All volatile organic analysis (VOA) and semi-volatile organic analysis (SVOA) were performed on the surface sample and all other analyses were performed on the variable depth sample. The information from this characterization will be used by Savannah River Remediation (SRR) for the transfer of aqueous waste from Tank 50H to the Saltstone Production Facility, where the waste will be treated and disposed of in the Saltstone Disposal Facility. This memorandum compares results, where applicable, to Saltstone Waste Acceptance Criteria (WAC) limits and targets. The chemical and radionuclide contaminant results from the characterization of the First Quarter CY17 sampling of Tank 50H were requested by SRR personnel and details of the testing are presented in the SRNL Task Technical and Quality Assurance Plan (TTQAP). This memorandum is part of Deliverable 2 from SRR request. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals will be documented at a later time per the TTQAP for the Tank 50H saltstone task.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dataset 2: A National Dataset on Human Choices in Pooled Rideshare, 2022

Dataset 2: A National Dataset on Human Choices in Pooled Rideshare, 2022. Dataset Description: Pooled Rideshare Acceptance Survey - Phase 2 (2022, N = 2,884). This dataset captures responses from a nationally representative sample of 2,884 adults across the United States to understand choice behaviors between personal and pooled rideshare services. The primary objective of this research is to investigate choice behaviors in rideshare services and provide insights that inform service design, policymaking, and transportation planning, with the aim of encouraging pooled rideshare adoption and enhancing transportation network energy efficiency. Data was collected via an online survey administered through a national panel provider. Participants ranged in age from 18 to 94 years, and representation from all U.S. regions. The survey was designed with a focus on investigating the stated-preference between personal and pooled rideshare services. Each participant responded to 20 stated-preference questions, where they were presented with a hypothesized situation to choose between a personal rideshare option and a pooled rideshare option to complete a trip. The sociodemographic information and attitudes towards factors of pooled rideshare acceptance were also collected to support the comprehensive investigation of participants’ rideshare choice behaviors. - Phase_2_Final - Each row represents an individual respondent, and each column corresponds to a variable such as stated-preference scenario attributes, stated-preference scenario responses, attitudes toward specific service features, and sociodemographic data. The data is available in both .CSV and .SAV formats. - Phase_2_Final_MapFile - The accompanying data dictionary explains all variable labels, response scales, and codes. An .XLSX format of the full survey instrument is included to support interpretation and reuse of the dataset.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improved sample utilization in thermal ionization mass spectrometry isotope ratio measurements: refined development of porous ion emitters for nuclear forensic applications

The precise and accurate determination of isotopic composition in nuclear forensic samples is vital for assessing origin, intended use and process history. Thermal ionization mass spectrometry (TIMS) is widely accepted as the gold standard for high performance isotopic measurements and has long served as the workhorse in the isotopic ratio determination of nuclear materials. Nuclear forensic and safeguard specialists have relied heavily on such methods for both routine and atypical e orts. Despite widespread use, TIMS methods for the assay of actinide systems continue to be hindered by poor ionization e ciency, often less than tenths of a percent; the majority of a sample is not measured. This represents a growing challenge in addressing nextgeneration nuclear detection needs by limiting the ability to analyze ultratrace quantities of high priority elements that could potentially provide critical nuclear forensic signatures. Porous ion emitter (PIE) thermal ion sources were developed in response to the growing need for new TIMS ion source strategies for improved ionization e ciency, PIEs have proven to be simple to implement, straightforward approach to boosting ion yield. This work serves to expand the use of PIE techniques for the analysis of trace quantities of plutonium and americium. PIEs exhibited superior plutonium and americium ion yields when compared to direct lament loading and the resin bead technique, one of the most e cient methods for actinide analysis, at similar mass loading levels. Initial attempts at altering PIE composition for the analysis of plutonium proved to enhance sample utilization even further. Preliminary investigations of the instrumental fractionation behavior of plutonium and uranium analyzed via PIE methods were conducted. Data collected during these initial trial indicate that PIEs fractionate in a consistent, reproducible manner; a necessity for high precision isotope ratio measurements. Ultimately, PIEs methods were applied for the age determination of various uranium isotopic standards. PIEs did not exhibit signi cant advantages for the determination of model ages when compared to traditional laments; however, this trial was able to provide valuable insight for guiding future investigations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of total and differential W + W - production cross sections in proton-proton collisions at √s=8 TeV with the ATLAS detector and limits on anomalous triple-gauge-boson couplings

The production of W boson pairs in proton-proton collisions at √s=8 TeV is studied using data corresponding to 20.3 fb -1 of integrated luminosity collected by the ATLAS detector during 2012 at the CERN Large Hadron Collider. The W bosons are reconstructed using their leptonic decays into electrons or muons and neutrinos. Events with reconstructed jets are not included in the candidate event sample. A total of 6636 WW candidate events are observed. Measurements are performed in fiducial regions closely approximating the detector acceptance. The integrated measurement is corrected for all acceptance effects and for the W branching fractions to leptons in order to obtain the total WW production cross section, which is found to be 71.1 ± 1.1(stat) -5.0+5.7(syst)±1.4(lumi) pb. This agrees with the next-to-next-to-leading-order Standard Model prediction of 63.2-1.4+1.6(scale)±1.2(PDF) pb. Fiducial differential cross sections are measured as a function of each of six kinematic variables. The distribution of the transverse momentum of the leading lepton is used to set limits on anomalous triple-gauge-boson couplings.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Enhancing pairwise state-transition weights: A new weighting scheme in simulated tempering that can minimize transition time between a pair of conformational states

Simulated tempering (ST) is a widely used enhancing sampling method for Molecular Dynamics simulations. As one expanded ensemble method, ST is a combination of canonical ensembles at different temperatures and the acceptance probability of cross-temperature transitions is determined by both the temperature difference and the weights of each temperature. One popular way to obtain the weights is to adopt the free energy of each canonical ensemble, which achieves uniform sampling among temperature space. However, this uniform distribution in temperature space may not be optimal since high temperatures do not always speed up the conformational transitions of interest, as anti-Arrhenius kinetics are prevalent in protein and RNA folding. Here, we propose a new method: Enhancing Pairwise State-transition Weights (EPSW), to obtain the optimal weights by minimizing the round-trip time for transitions among different metastable states at the temperature of interest in ST. The novelty of the EPSW algorithm lies in explicitly considering the kinetics of conformation transitions when optimizing the weights of different temperatures. We further demonstrate the power of EPSW in three different systems: a simple two-temperature model, a two-dimensional model for protein folding with anti-Arrhenius kinetics, and the alanine dipeptide. The results from these three systems showed that the new algorithm can substantially accelerate the transitions between conformational states of interest in the ST expanded ensemble and further facilitate the convergence of thermodynamics compared to the widely used free energy weights. We anticipate that this algorithm is particularly useful for studying functional conformational changes of biological systems where the initial and final states are often known from structural biology experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heisenberg model analysis on inelastic powder neutron scattering data using parent and K doped BaMn 2 As 2 samples

Low temperature powder inelastic neutron scattering measurements were performed on three different powder samples; parent BaMn 2 As 2 ,12.5% K-doped Ba 0.875 K 0.125 Mn 2 As 2 and 25% K-doped Ba (0.75) K 0.25 Mn 2 As 2 . The Heisenberg Model involving J 1 -J 2 -J z coupling constants were compared to the data by a powder integration routine using Monte Carlo integration methods. The best magnetic parameters were selected using a chi-square test where model intensities were compared to the full (q,E) dependence of magnetic scattering. A key step to this analysis is the characterization of the background which is formed mostly by phonon scattering intensities along with other sources including the magnetic impurity scattering events. The calculated powder magnetic intensities added to the estimated background obtained from the non-magnetic high momentum transfer region. The agreement between the simulated and the raw data enabled us to perform quantitative analysis of the unreacted MnO impurities. Overall, this is another confirmation along with earlier studies using this technique, that magnetic exchange constants can be calculated within an acceptable range with a very quick inelastic neutron powder experiment without need for a single crystal sample.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sampling command generator corrects for noise and dropouts in recorded data

Generator measures period between zero crossings of reference signal and accepts as correct timing points only those zero crossings which occur acceptably close to nominal time predicted from last accepted command. Unidirectional crossover points are used exclusively so errors from analog nonsymmetry of crossover detector are avoided.

Anderson, T. O.↗

Total metals & anion concentration data; Slate River floodplain, Crested Butte, CO; May 2020-September 2020

This data package includes processed and undiluted measurements for metal and anion concentrations from pore water (groundwater) samples from the Slate River floodplain of Crested Butte, CO, a focus field site for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between May and September of 2020. These measurements were all recorded at the Arizona Laboratory for Emerging Contaminants (ALEC) at the University of Arizona located in Tucson, AZ. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 4C until measured at ALEC.Analysis by ICP-MS:Measurements for total metals were made on the Agilent 7700x ICP-MS (for total metals) – Agilent Technologies, Santa Clara, CA.The analytical QA/QC protocol was adapted from US EPA Method 200.8 for analysis by ICP-MS. Calibration standards were prepared from multi-element stock solution (Sigma-Aldrich Multielement standard solution for ICP, St. Louis, MO) using matrix matched to sample solutions (either 2% HCl or HNO3 from AriStar Plus,grade acids from VWR Scientific). Calibration curves include at least 7 points with correlation coefficients > 0.995. The QC protocol includes a continuing calibration blank (CCB), a continuing calibration verification (CCV) solution and at least one quality control sample (QCS) to be analyzed just after calibration and again after every 12 samples and at the completion of the run. The QCS solutions are from an independent source, such as NIST SRM 1643e - Trace Elements in Water, or QCS solutions from High Purity Standards (Charleston, SC). Acceptable QC responses must be between 90 and 110% of the certified value. An internal standard (Rh) is added via on-line addition into the sample line using a mixing tee.Analysis by Ion Chromatography (Anions):The protocol follows Method 4110 in Standard Methods for Examination of Water and Wastewater.The instrument used is the Thermo Scientific Dionex ICS-6000 using AS+AG22 column set for anion analysis with isocratic method using sodium carbonate eluent. Detection is by chemical suppression of eluent conductivity. Quality control solutions and mixed analyte standards purchased from Inorganic Ventures, Christiansburg, VA.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

Results for the Fourth Quarter Calendar Year 2018 Tank 50 Salt Solution Sample

In this Technical Report, the chemical and radionuclide contaminant results from the Fourth Quarter Calendar Year 2018 (CY18) sample of Tank 50 salt solution are presented in tabulated form. The information from this characterization will be used by Savannah River Remediation (SRR) for the transfer of aqueous waste from Tank 50 to the Saltstone Production Facility (SPF), where the waste will be treated and disposed in the Saltstone Disposal Facility. This Technical Report compares results, where applicable, to SPF Waste Acceptance Criteria (WAC) Limits and Targets. The chemical and radionuclide contaminant results from the characterization of the Fourth Quarter CY18 sampling of Tank 50 were requested by SRR personnel via a Task Technical Request (TTR) and details of the testing are presented in the Savannah River National Laboratory (SRNL) Task Technical and Quality Assurance Plan (TTQAP). This Technical Report is part of Deliverable 2 relating to Task 1 from the SRR request. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals will be documented at a later time per the TTQAP for the Tank 50 Saltstone task.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results for the Fourth Quarter Calendar Year 2018 Tank 50 Salt Solution Sample

In this Technical Report, the chemical and radionuclide contaminant results from the Fourth Quarter Calendar Year 2018 (CY18) sample of Tank 50 salt solution are presented in tabulated form. The information from this characterization will be used by Savannah River Remediation (SRR) for the transfer of aqueous waste from Tank 50 to the Saltstone Production Facility (SPF), where the waste will be treated and disposed in the Saltstone Disposal Facility. This Technical Report compares results, where applicable, to SPF Waste Acceptance Criteria (WAC) Limits and Targets. The chemical and radionuclide contaminant results from the characterization of the Fourth Quarter CY18 sampling of Tank 50 were requested by SRR personnel via a Task Technical Request (TTR) and details of the testing are presented in the Savannah River National Laboratory (SRNL) Task Technical and Quality Assurance Plan (TTQAP). This Technical Report is part of Deliverable 2 relating to Task 1 from the SRR request. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals will be documented at a later time per the TTQAP for the Tank 50 Saltstone task.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results for the First Quarter Calendar Year 2018 Tank 50 Salt Solution Sample

In this Technical Report, the chemical and radionuclide contaminant results from the First Quarter Calendar Year 2018 (CY18) sample of Tank 50 salt solution are presented in tabulated form. The information from this characterization will be used by Savannah River Remediation (SRR) for the transfer of aqueous waste from Tank 50 to the Saltstone Production Facility, where the waste will be treated and disposed of in the Saltstone Disposal Facility. This Technical Report compares results, where applicable, to Saltstone Waste Acceptance Criteria (WAC) limits and targets. The chemical and radionuclide contaminant results from the characterization of the First Quarter CY18 sampling of Tank 50 were requested by SRR personnel via a Task Technical Request (TTR) 2 and details of the testing are presented in the Savannah River National Laboratory (SRNL)Task Technical and Quality Assurance Plan (TT QAP). This Technical Report is part of Deliverable 2 relating to Task 1 from the SRR request. 2 Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals will be documented at a later time per the TTQAP for the Tank 50 Saltstone task.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗