Search NASA⌕ Search

SEARCH · Search NASA

Results for “all hazards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Development of a stoichiometric magnesium potassium phosphate cement (MKPC) for the immobilization of powdered minerals

Ordinary Portland Cement (OPC)-based materials are not systematically adapted for immobilizing industrial hazardous waste, e.g. for aluminium powder or plutonium waste sludge. In such case, Magnesium Potassium Phosphate Cements (MKPC) represent an interesting alternative. }The originality of this research is to develop a formulation of a MKPC paste for hazardous waste immobilization, which incorporates a maximum amount of such waste, preferably in powdered form. To this purpose, a stoichiometric MKPC paste is selected, and its properties are improved by powdered waste addition. }Firstly, the physico-chemical mechanisms generating expansion in stoichiometric MKPC paste are analyzed. Swelling is attributed to a pH gradient in the paste, due to the progressive sedimentation of MgO particles in the fresh mix. }Secondly, over-stoichiometric MgO is replaced by varying amounts of minerals simulating the waste, of different mineralogy and granulometry, in order to achieve sufficient workability and no swelling. An optimal formulation is proposed, which incorporates powdered fly ash at a fine-to-cement mass ratio (F/C) of 1. Its mechanical performance and endogenous dimensional changes are comparable to typical over-stoichiometric pastes, and they stabilize between 7 and 28 days.

36 MATERIALS SCIENCE↗

Incidence of chronic respiratory conditions among oil spill responders: Five years of follow-up in the Deepwater Horizon Oil Spill Coast Guard Cohort study

Background: Over ten years after the Deepwater Horizon (DWH) oil spill, our understanding of long term respiratory health risks associated with oil spill response exposures is limited. Here we conducted a prospective analysis in a cohort of U.S. Coast Guard personnel with universal military healthcare. Methods: For all active duty cohort members (N = 45,193) in the DWH Oil Spill Coast Guard Cohort Study we obtained medical encounter data from October 01, 2007 to September 30, 2015 (i.e., ~2.5 years pre-spill; ~5.5 years post-spill). We used Cox Proportional Hazards regressions to calculate adjusted hazard ratios (aHR), comparing risks for incident respiratory conditions/symptoms (2010–2015) for: responders vs. non-responders; responders reporting crude oil exposure, any inhalation of crude oil vapors, and being in the vicinity of burning crude oil versus responders without those exposures. We also evaluated self-reported crude oil and oil dispersant exposures, combined. Within-responder comparisons were adjusted for age, sex, and smoking. Results: While elevated aHRs for responder/non-responder comparisons were generally weak, within-responder comparisons showed stronger risks with exposure to crude oil. Notably, for responders reporting exposure to crude oil via inhalation, there were elevated risks for all sinusitis (aHR = 1.48; 95%CI, 1.06–2.06), unspecified chronic sinusitis (aHR = 1.55; 95%CI, 1.08–2.22), chronic obstructive pulmonary disease (COPD) and other allied conditions (aHR = 1.43; 95%CI, 1.00–2.06), and dyspnea and respiratory abnormalities (aHR = 1.29; 95%CI, 1.00–1.67); there was a suggestion of elevated risk for diseases classified as asthma and reactive airway diseases (aHR = 1.18; 95%CI, 0.98–1.41), including the specific condition, asthma (aHR = 1.35; 95%CI, 0.80–2.27), the symptom, shortness of breath (aHR = 1.50; 95%CI, 0.89–2.54), and the overall classification of chronic respiratory conditions (aHR = 1.18; 95%CI, 0.98–1.43). Exposure to both crude oil and dispersant was positively associated with elevated risk for shortness of breath (HR = 2.24; 95%CI, 1.09–4.64). Conclusions: Among active duty Coast Guard personnel, oil spill clean-up exposures were associated with moderately increased risk for longer term respiratory conditions.

54 ENVIRONMENTAL SCIENCES↗

Modeling the impact of smoke from prescribed fire on road visibility

Prescribed fires are planned to achieve conservation and fuel reduction objectives while minimizing smoke ground concentration to limit health impacts and road visibility impairment. Prescribed burns cannot indeed be conducted if those hazards are not within predefined limits. This paper proposes a new framework to evaluate road visibility that overcomes the limitation of the state of the art model, VSMOKE. The framework leverages the fast-running framework QUIC-Fire/QUIC-SMOKE to capture fire and smoke dynamics, and the timing and duration of hazardous conditions on the road network close to the burn unit (within 50–100 km). The paper presents parametric study using a real burn plot at Fort Stewart (GA, USA), under hypothetical wind conditions to understand the interplay between buoyancy and smoke dilution. Here, results showed that faster winds caused fire escape while slower winds did not achieve a complete burn. Furthermore, faster winds featured brief road visibility reduction below braking distance.

54 ENVIRONMENTAL SCIENCES↗

Mechanically induced thermal runaway severity analysis for Li-ion batteries

Thermal runaway is one of the most important safety concerns in the deployment of Li-ion batteries. For this study, we developed a standardized single-side indentation test protocol to induce an internal short-circuit. Cell voltage, temperature, and applied compressive force are monitored as a function of time. Each cell is given an observed hazard severity (OHS in five categories) modified from the EUCAR table. Meanwhile a calculated hazard severity (CHS) is obtained solely based on temperature and voltage curves. The calculation formula considers the cell temperature, rate of temperature increase, cell capacity, state of charge (SOC), voltage drop, and voltage drop rate. Each term is assigned with an appropriate weight to scale the calculated score from 0 to100. This method was applied to >100 Li-ion batteries with various SOCs and chemistries, and their OHS and CHS were displayed against SOC. The purpose is to provide battery designers, manufacturers, and end-users a clear comparison of thermal runaway severity of different batteries.

25 ENERGY STORAGE↗

Sidewall Breach During Lithium-Ion Battery Thermal Runaway Triggered by Cell-to-Cell Propagation Visualized Using High-Speed X-Ray Imaging

With the rapid deployment of Li-ion batteries (LiBs) in a range of applications, it is crucial to ensure their safe operation. Therefore, it is necessary to investigate the rapid thermal runaway failure that LiBs can undergo if improperly operated or subjected to abuse scenarios so that hazardous events can be avoided or mitigated. Sidewall breaches or ruptures of LiBs during thermal runaway are considered the most hazardous failure scenario, resulting in hot abrasive flare from the casing of the cell that can impinge on neighbouring cells and lead to the propagation of thermal runaway throughout a battery pack. Yet, the process leading up to the sidewall breach is not well understood due to the extreme difficulty in visualizing such a failure in commercially relevant cells. With the application of a newly developed chamber for remote-controlled abuse testing of batteries coupled with simultaneous X-ray imaging, we demonstrate here for the first time an in-situ visualization of a sidewall breach. By further applying spatiotemporal mapping techniques, the internal thermal runaway events leading up to the sidewall breach can be analyzed in detail. Subsequently, the speed of the electrode layer delamination could be calculated to a speed of 0.6 m/s. These new insights bring more clarity regarding this phenomenon, that in turn can help battery designers improve battery safety.

battery safety↗

Risk of Mortality in Family Members of Men Seeking Fertility Assessment

Objective: To assess mortality in family members of men seeking fertility assessment. Subfertility serves as a biomarker for overall somatic health, and poor semen quality is associated with increased risk of hospitalization and mortality from chronic conditions. However, it is unclear if these risks extend to family members of men with low sperm count. Design: Retrospective cohort study. Subjects: Family members, up to third-degree relatives, of men in the Subfertility, Health and Assisted Reproduction and the Environment cohort who underwent a semen analysis as part of a fertility assessment 1996–2017. Relatives of men with a recorded total sperm count who lived in Utah for ≥1 year 1904–2017 were included in the analysis (N = 22,280 families). Exposure: Individuals were classified by family membership. Families were classified as relatives of azoospermic (0M), oligozoospermic (<39M), or normozoospermic (≥39M) men. The average total sperm count of the proband (male relative) with fertility assessment was also included as a continuous exposure measure. Main Outcome Measures: The main outcomes were all-cause and cause-specific mortality risk by sex, age, and degree of relation: first-, second-, and third-degree. Cox proportional hazard models were used to test the association between fertility classification and mortality, controlling for sex, race/ethnicity, and birth year. Results: A total of 666,437 relatives of men with fertility assessment (N deaths = 183,974) were included in the analysis. Relative to normozoospermia families, all-cause mortality risk increased in oligozoospermia families (hazard ratio [HR] oligozoospermia , 1.03; 95% confidence interval [CI], 1.01–1.05). Close relatives, first- (HR oligozoospermia , 1.17; 95% CI, 1.07–1.28) and second-degree relatives (HR azoospermia , 1.11; 95% CI, 1.04–1.20; HR oligozoospermia , 1.05; 95% CI,1.01–1.09), of azoospermic and oligozoospermic men had the highest all-cause and cause-specific mortality risk, including death attributed to cardiovascular disease or congenital birth conditions. Conclusion: Our results suggest that familial all-cause and cause-specific mortality risk differ by fertility phenotype. Families of azoospermic and oligozoospermic men showed significantly increased risk, particularly for close relatives. This study provides further evidence that shared genetic and/or environmental factors could influence both fertility and somatic health.

Male fertility↗

The 2017 Pohang, South Korea, Mw 5.4 main shock was either natural or triggered, but not induced

Understanding the cause of the November 2017 Pohang main shock is of considerable importance to the future of the geothermal industry because of its large magnitude compared to prior expectations based on case histories of other projects involving underground fluid injection. Of the three possibilities – induced, triggered or natural, “induced” can be ruled out based on the disproportionately large seismic moment of the main shock. Furthermore, whether natural or triggered, the source of seismic hazard at Pohang was tectonic strain accumulation, not fluid injection. Arguably, the most timely indicator of seismic hazard and risk in the environs of Pohang was the September 2016 Mw 5.4 Gyeongju earthquake, which was natural and located about 40 km south of Pohang along the same active fault system.

58 GEOSCIENCES↗

Exploring Wildfire & Energy data toward State Prioritization Index (WESPI)

Energy infrastructure can both induce and suffer risks from wildfires ranging from direct damage to energy assets such as substations and power lines to Public Safety Power Shutoffs. Recent wildfire events underscore the need for data-driven approaches that help states and utilities proactively plan for wildfire risk. Existing national tools such as Federal Emergency Management Agency (FEMA)’s National Risk Index (NRI) are valuable for community hazard planning. However, they are less suited for energy infrastructure, as they emphasize population and building exposure rather than system vulnerabilities. In this paper, we explore relationships between energy and wildfire data and present a Wildfire-Energy State Prioritization Index (WESPI). Our methodology combines data from the US Forest Service’s Fire Simulation (FSIM) dataset with energy resilience metrics, historical fire incidents, and geospatial data on transmission lines and fire stations. Correlation analyses suggest that FSIM burn probability is more strongly associated with power outage metrics (ρ = 0.32) than NRI wildfire frequency, and counties with a greater density of fire stations experience more frequent, but less intense wildfires. We further leverage data for burn probability, transmission line density, and fire station density to develop a Wildfire-Energy State Prioritization Index (WESPI) to highlight counties where wildfire hazard, infrastructure exposure, and limited suppression capacity converge. The index provides a consistent, scalable framework for state energy offices and utilities to screen counties for vegetation management, optimization of outage management system deployment, and to inform wildfire mitigation plans.

Critical infrastructure↗

Investigating the Determinants of Household Capabilities Burden During Power Outages: The Case of Winter Storm Uri

Existing research primarily uses census data to identify the vulnerability of communities to hazards. These vulnerability indices provide aggregated data and are not hazard-specific nor well-validated with post-event data. In contrast, our study uses household survey data (n=1065) to understand which Texan households suffered the greatest loss of their capabilities due to power outages and other utility service disruptions during Winter Storm Uri. Inspired by the Capabilities Approach, our measures of burden include the number of household capability types disrupted during the outages (e.g., cooking, heating, refrigeration), the severity of impact for each disrupted capability, and the additional time and financial costs of coping with these disruptions. We perform a clustering analysis, and find two distinct groups in our data, consisting of ‘lesser burden' and ‘heavier burden' households. Results indicate that the households experiencing the heaviest capabilities burden were most likely to experience longer power outages and the loss of water services. They were also more likely to have a Hispanic-Latino household member, lack access to a generator, live in a rented home, have larger households with more young children, fewer adults over 65, lower household incomes, been impacted by the COVID-19 pandemic, and more family characteristics that made life harder. We also fit a logistic regression model to assess the role of outage, household, and community characteristics in predicting differences in capabilities burden. Our results offer insights into enumerating the consequences of utility service disruptions on households, which can inform more targeted and equitable resilience strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CO 2 Pipeline risk assessment and comparison for the midcontinent United States

For this work, a comprehensive quantitative risk assessment for the construction and operation of CO 2 transportation networks considered for the Midcontinent United States was conducted. The results showed risks associated with CO 2 pipelines were significantly less than those of other pipeline types. The assessment used four conceptual pipelines of different lengths to discuss risks operators may see. The assessment evaluated the risk associated with construction and operation using data from the US Occupational Safety Health Administration to determine the risk of injury or death for pipeline workers and data from the US Pipeline and Hazardous Materials Safety Administration for CO 2 , natural gas distribution, natural gas transmission/gathering, and non-CO 2 hazardous liquid pipelines to develop quantitative likelihood and severity values leading to risk values. The data for the assessment covered incidents from 2010 to 2017 for CO 2 pipelines. The average risk for construction and 30 years of operation for four CO 2 pipeline configurations ranging between 79 and 1,546 miles in length was found. The construction and operational risk averaged between $\$1,400,521$ (approximately $\$0.02$/tonne of CO 2 ) for the shorter pipeline (79 miles) and $\$27,481,939$ (approximately $\$0.10$/tonne of CO 2 ) for a longer pipeline (1,546 miles). The largest risks of fatality for CO 2 pipelines comes from vehicle transport. The largest operational risk to the pipeline was due to leakage. Public pipeline opposition is also a significant risk; it was not quantified but is addressed.

03 NATURAL GAS↗

Development of risk mitigation guidance for sensor placement inside mechanically ventilated enclosures – Phase 1

Guidance on Sensor Placement was identified as the top research priority for hydrogen sensors at the 2018 HySafe Research Priority Workshop on hydrogen safety in the category Mitigation, Sensors, Hazard Prevention, and Risk Reduction. This paper discusses the initial steps (Phase 1) to develop such guidance for mechanically ventilated enclosures. This work was initiated as an international collaborative effort to respond to emerging market needs related to the design and deployment equipment for hydrogen infrastructure that is often installed in individual equipment cabinets or ventilated enclosures. The ultimate objective of this effort is to develop guidance for an optimal sensor placement such that, when integrated into a facility design and operation, will allow earlier detection at lower levels of incipient leaks, leading to significant hazard reduction. Reliable and consistent early warning of hydrogen leaks will allow for the risk mitigation by reducing or even eliminating the probability of escalation of small leaks into large and uncontrolled events. To address this issue, a study of a real-world mechanically ventilated enclosure containing GH2 equipment was conducted, where CFD modeling of the hydrogen dispersion (performed by AVT and UQTR, and independently by the JRC) was validated by the NREL Sensor laboratory using a Hydrogen Wide Area Monitor (HyWAM) consisting of a 10-point gas and temperature measurement analyzer. In the release test, helium was used as a hydrogen surrogate. Expansion of indoor releases to other larger facilities (including parking structures, vehicle maintenance facilities and potentially tunnels) and incorporation into QRA tools, such as HyRAM is planned for Phase 2. It is anticipated that results of this work will be used to inform national and international standards such as NFPA 2 Hydrogen Technologies Code, Canadian Hydrogen Installation Code (CHIC) and relevant ISO/TC 197 and CEN documents.

08 HYDROGEN↗

Risk assessment and ventilation modeling for hydrogen releases in vehicle repair garages

The availability of repair garage infrastructure for hydrogen fuel cell vehicles is becoming increasingly important for future industry growth. Ventilation requirements for hydrogen fuel cell vehicles can affect both retrofitted and purpose-built repair garages and the costs associated with these requirements can be significant. A hazard and operability (HAZOP) study was performed to identify risk-significant scenarios related to light-duty hydrogen vehicles in a repair garage. Detailed simulations and modeling were performed using appropriate computational tools to estimate the location, behavior, and severity of hydrogen release based on key HAZOP scenarios. Here, this work compares current fire code requirements to an alternate ventilation strategy to further reduce potential hazardous conditions. Modeling shows that position, direction, and velocity of ventilation have a significant impact on the amount of instantaneous flammable mass in the domain.

08 HYDROGEN↗

Overcharge-to-thermal-runaway behavior and safety assessment of commercial lithium-ion cells with different cathode materials: A comparison study

In this paper, overcharge behaviors and thermal runaway (TR) features of large format lithium-ion (Li-ion) cells with different cathode materials (LiFePO 4 (LFP), Li[Ni 1/3 Co 1/3 Mn 1/3 ]O 2 (NCM111), Li[Ni 0.6 Co 0.2 Mn 0.2 ]O 2 (NCM622) and Li[Ni 0.8 Co 0.1 Mn 0.1 ]O 2 (NCM811)) were investigated. The results showed that, under the same overcharge condition, the TR of LFP Li-ion cell occurred earlier compared with the NCM Li-ion cells, indicating its poor overcharge tolerance and high TR risk. However, when TR occurred, LFP Li-ion cell exhibited lower maximum temperature and mild TR response. All NCM Li-ion cells caught fire or exploded during TR, while the LFP Li-ion cell only released a large amount of smoke without fire. According to the overcharge behaviors and TR features, a safety assessment score system was proposed to evaluate the safety of the cells. In short, NCM Li-ion cells have better performance in energy density and overcharge tolerance (or low TR risk), while LFP Li-ion cell showed less severe response to overcharging (or less TR hazards). For NCM Li-ion cells, as the ratio of nickel in cathode material increases, the thermal stability of the cathode materials becomes poorer, and the TR hazards increase. Such a comparison study on large format Li-ion cells with different cathode materials can provide deeper insights into the overcharge behaviors and TR features, and provide guidance for engineers to reasonably choose battery materials in automotive applications.

25 ENERGY STORAGE↗

A Perspective on Biomass-Derived Biofuels: From Catalyst Design Principles to Fuel Properties

The hazards to health and the environment associated with the transportation sector include smog, particulate matter, and greenhouse gas emissions. Conversion of lignocellulosic biomass into biofuels has the potential to provide significant amounts of infrastructure-compatible liquid transportation fuels that reduce those hazardous materials. However, the development of these technologies is inefficient, due to: (i) the lack of a priori fuel property consideration, (ii) poor shared vocabulary between process chemists and fuel engineers, and (iii) modern and future engines operating outside the range of traditional autoignition metrics such as octane or cetane numbers. In this perspective, we describe an approach where we follow a “fuel-property first” design methodology with a sequence of (i) identifying the desirable fuel properties for modern engines, (ii) defining molecules capable of delivering those properties, and (iii) designing catalysts and processes that can produce those molecules from a candidate feedstock in a specific conversion process. Computational techniques need to be leveraged to minimize expenses and experimental efforts on low-promise options. This concept is illustrated with current research information available for biomass conversion to fuels via catalytic fast pyrolysis and hydrotreating; outstanding challenges and research tools necessary for a successful outcome are presented.

BIOMASS FUELS↗

Removal of deuterium retained in boron powder by oxygen or high-temperature bakeout

Fuel retention in dust accumulated in fusion devices is a potential operational hazard. Boronization is one of the leading wall-conditioning candidates for future fusion devices. Fuel retention characteristics of boron dust must be studied to accurately understand the potential hazards of boron dust in fusion devices. We evaluated the retention of deuterium (D) in commercially available boron powder as a proxy for tritium retention in boron dust. Diffuse reflectance infrared Fourier transform spectroscopy revealed that boron powder between 300 and 500 K exposed to neutral hydrogen (H 2 ) gas retains H via B-H bonding. We utilized D 2 exposures of 17,400 L on the boron powder, which led to retention on the order of 0.5 g D per 100 kg B or 1.2 g D per m 2 B, as estimated from temperature programmed desorption measurements. We evaluated how powder bakeouts under ultra-high vacuum (UHV), or in an oxygen (O 2 ) or H 2 gas backfilled environment can remove the retained fuel. Bakeouts below 523 K under UHV exhibited poor D removal, promoting recapture of D 2 present as background gas in the chamber. Higher temperature bakeouts led to the removal of over 80% of the retained D within 3 days (623 K) or 1 h (723 K). Bakeouts at 423 K under an O 2 gas environment removed ∼150% more retained D from the boron powder, when compared to bakeouts conducted under UHV. These results suggest that efficient fuel removal from boron dust can be achieved by high-temperature bakeout (>623 K) or by bakeouts at lower temperature (423 K) under an O 2 environment.

Bakeout↗

Identification of drug repurposing candidates for amyotrophic lateral sclerosis using electronic health records: a retrospective cohort study

Amyotrophic lateral sclerosis (ALS) is a progressive neurodegenerative disease with a life expectancy of only 3–5 years and few approved treatments. To identify drug repurposing candidates for the treatment of ALS, we analysed the electronic health records (EHRs) of a large cohort of military veterans with ALS. We analysed the EHRs of individuals in the US Veterans Health Administration (VHA) database who were diagnosed with ALS between Jan 1, 2009 and Dec 31, 2019 to assess medication effects. Individuals without recorded prescriptions after the date of diagnosis were excluded. Two sets of criteria were applied to ascertain exposure. Exposure criteria A were met if the dispense date or the end date of the medication was within 12 months of ALS diagnosis and the end date was at least 6 months after the dispense date. Exposure criteria B were met if there were at least two dispenses within 6 months before diagnosis and 12 months after diagnosis. Propensity score-matched control groups were generated on the basis of confounders included in the EHR, with methodology of potential outcomes used to infer treatment effects. The primary outcome was death. A standard Cox proportional hazards analysis was done to assess association with survival. Survival was defined as the time from diagnosis date recorded in the EHR to death reported in the Department for Veterans Affairs Vital Status File. Follow-up survival time was censored on Dec 31, 2020, for those alive on this date. Downstream protein targets of drugs with clinically significant effects were analysed using the protein–protein interaction networks-based algorithm PathFX. The EHRs of 11 003 individuals with ALS in the VHA database were appropriate for analysis. 162 medications with treatment groups of 30 or more individuals were identified. Among these 162 medications, 27 were associated with statistically significant changes (≥0·1) in the hazard ratio (HR) for death. 18 of the medications were associated with a reduced HR for death (prolonged survival), and nine were associated with an increased HR for death (reduced survival). Drugs associated with reduced HR included HMG-CoA reductase inhibitors (simvastatin, pravastatin, lovastatin, and atorvastatin), PDE5 inhibitors (vardenafil and sildenafil), and α-adrenergic antagonists (tamsulosin and terazosin). The medications associated with an increased HR were drugs used either in the management of clinical features of ALS associated with poor outcomes or in end-of-life care. PathFx analysis identified a complex of proteins interacting with several of the identified drugs. To our knowledge, this analysis is the largest EHR-based study for identifying drug repurposing candidates for ALS. We identified several drugs that warrant further assessment as therapeutic options in ALS, as well as a protein network complex that might serve as a therapeutic target for ALS.

Reimer, Richard J. [Stanford Univ., CA (United Sta↗

An expert-driven literature review of “negative” chemicals for developmental neurotoxicity (DNT) in vitro assay evaluation

To date, approximately 200 chemicals have been tested in US Environmental Protection Agency (EPA) or Organization for Economic Co-operation and Development (OECD) developmental neurotoxicity (DNT) guideline studies, leaving thousands of chemicals without traditional animal information on DNT hazard potential. To address this data gap, a battery of in vitro DNT new approach methodologies (NAMs) has been proposed. Evaluation of the performance of this battery will increase the confidence in its use to determine DNT chemical hazards. One approach to evaluate DNT NAM performance is to use a set of chemicals to evaluate sensitivity and specificity. Since a list of chemicals with potential evidence of in vivo DNT has been established, this study aims to develop a curated list of “negative” chemicals for inclusion in a “DNT NAM evaluation set”. A workflow, including a literature search followed by an expert-driven literature review, was used to systematically screen 39 chemicals for lack of DNT effect. Expert panel members evaluated the scientific robustness of relevant studies to inform chemical categorizations. Following review, the panel discussed each chemical and made categorical determinations of “Favorable”, “Not Favorable”, or “Indeterminate” reflecting acceptance, lack of suitability, or uncertainty given specific limitations and considerations, respectively. Further, the panel determined that 10, 22, and 7 chemicals met the criteria for “Favorable”, “Not Favorable”, and “Indeterminate”, for use as negatives in a DNT NAM evaluation set. Ultimately, this approach not only supports DNT NAM performance evaluation but also highlights challenges in identifying large numbers of negative DNT chemicals.

59 BASIC BIOLOGICAL SCIENCES↗

Towards standardized nuclear reactors: Seismic isolation and the cost impact of the earthquake load case

We report nuclear energy has a key role to play in global decarbonization. Impediments to the widespread deployment of reactors are their projected high capital cost and levelized cost of energy, and time required to analyze, design, license, construct, and commission them. The earthquake load case is a key cost driver for a new build nuclear plant, because near-surface soils and seismic hazard are different at each site, requiring site-specific analysis, design, engineering, qualification, licensing, and regulatory review, essentially making every design First-of-a-Kind (FoaK). To enable deployment at the scale needed for deep decarbonization, the cost and time impact of the seismic load case must be significantly mitigated, and plants must be standardized. Seismic base isolation has been proven to considerably reduce the earthquake response of structures and equipment but has yet to be applied to a nuclear power plant in the United States, in part because the financial impacts, positive or negative, are not known. Because there are no recent non-proprietary data to characterize the influence of the seismic load case on capital cost, it is difficult to confidently quantify the financial benefits of seismic isolation. Scheme-level designs of two fundamentally different advanced reactor buildings were developed to assemble cost data on the influence of the seismic load case. Both buildings were equipped with three bespoke pieces of safety-related equipment and analyzed for incremented levels of earthquake shaking to quantify the seismic penalty on equipment, in terms of vessel weights and horizontal accelerations. Using analysis results, a questionnaire was developed and transmitted to nuclear utilities, reactor developers, engineers, and equipment suppliers to collect cost data on engineering and fabrication costs for these unique pieces of safety-class equipment. Synthesis of the cost data showed that the seismic load case significantly affects the capital cost (sum of engineering and fabrication cost) of safety-class equipment, with engineering costs being comparable to fabrication costs. Standardization of safety-class equipment is made possible by seismic isolation, that is, equipment designed for minimal seismic robustness can resist earthquake shaking at a site of much higher seismic hazard. The average reduction in the capital cost of the safety-related equipment, enabled by seismic isolation, is a factor of two for FoaK equipment and a factor of five for standardized equipment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗