Multi-channel programmable power supply with temperature compensation for silicon sensors

Silicon Photo-Multipliers (SiPMs) are increasingly becoming popular for discrete photon counting applications due to the wealth of advantages they offer over conventional photo-detectors such as photo-multiplier tubes and hybrid photo-diodes. SiPMs are used in variety of applications ranging from high energy physics and nuclear physics experiments to medical diagnostics. The gain of a SiPM is directly proportional to the difference between applied and breakdown voltage of the device. However, the breakdown voltage depends critically on the ambient temperature and has a large temperature co-efficient in the range of 40-60 mV/°C resulting in a typical gain variation of 3%-5%/°C [Dinu et al., in IEEE Nuclear Science Symposium, Medical Imaging Conference and 17th Room Temperature Semiconductor Detector Workshop (IEEE, 2010), p. 215]. We plan to use the SiPM as a replacement for PMT in the cosmic ray experiment (GRAPES-3) at Ooty [Gupta et al., Nucl. Instrum. Methods Phys. Res., Sect. A 540, 311 (2005)]. There the SiPMs will be operated in an outdoor environment subjected to temperature variation of about 15 °C over a day. A gain variation of more than 50% was observed for such large variations in the temperature. To stabilize the gain of the SiPM under such operating conditions, a low-cost, multi-channel programmable power supply (0-90 V) was designed that simultaneously provides the bias voltage to 16 SiPMs. The programmable power supply (PPS) was designed to automatically adjust the operating voltage for each channel with a built-in closed loop temperature feedback mechanism. The PPS provides bias voltage with a precision of 6 mV and measures the load current with a precision of 1 nA. Using this PPS, a gain stability of 0.5% for SiPM (Hamamatsu, S10931-050P) has been demonstrated over a wide temperature range of 15 °C. The design methodology of the PPS system, its validation, and the results of the tests carried out on the SiPM is presented in this article. The proposed design also has the capability of gain stabilization of devices with non-linear thermal response.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heave Plate Hydrodynamic Coefficients for Floating Offshore Wind Turbines - A Compilation of Data

The National Renewable Energy Laboratory's OpenFAST software is utilized by academics and industry professionals alike to simulate offshore wind turbines. The software's modeling of hydrodynamic loads on heave plates attached to these structures relies on user-specified hydrodynamic coefficients. To guide the proper selection of these coefficients and potentially develop a new functionality within OpenFAST that automatically prescribes and/or adjusts the heave-plate hydrodynamic coefficients, we review past literature to examine the dependence of the added mass, damping, and drag coefficients on various relevant nondimensional parameters, including the Keulegan-Carpenter number, the frequency parameter, and the plate thickness ratio. Existing data in the literature show strong dependence of the hydrodynamic coefficients on the Keulegan-Carpenter number. We observe consistent trends across a range of different plate geometry, plate porosity, and flow conditions. Secondary dependence of the coefficients on the frequency parameter and plate thickness ratio is also present.

added mass↗

Field Validation of Air-Source Heat Pumps for Cold Climates

Heating energy is the largest end-use for U.S. residential buildings accounting for approximately one-third of residential building energy consumption (EIA 2021). Historically, air-source heat pumps have been limited to temperate climates because of subpar performance at extremely cold outdoor air temperatures. However, recent advances to cold-climate air-source heat pump technology, which typically rely on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance enabling the technology to save energy for many homes in cold climates. The primary objective of this project was to measure in-field performance of centrally ducted, variable-capacity air-source heat pumps in cold climates to validate performance and develop field-based performance maps. The project focused on quantifying heat pump performance at cold temperatures. The sites identified for the study were primarily located in the Northwest United States since homes in the region tend to have all-electric space heating systems and high-efficiency heat pumps have been incentivized in the region for several years. NREL partnered with Ecotope, Inc., a small energy consulting firm located in Seattle, WA, for site recruitment, monitoring equipment installation, data quality management. All the sites included in the study had previously installed a high-efficiency, central heat pump system. One site was in a Denver, CO suburb, which was the only dual fuel heat pump in the study. We used airside and power measurements, collected at 5-second intervals, to quantify heat pump capacity, coefficient of performance (COP), and auxiliary heater energy consumption. We developed algorithms to automatically determine the heat pump operating mode including defrost and auxiliary heating operation. A whole-house thermal and duct audit was completed during the initial site visit to estimate winter heating loads and assess heat pump sizing. Whole-home heating design loads were calculated at ASHRAE 99% design temperatures and compared to manufacturer-reported maximum capacities to assess the heat pump sizing at each site.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Economical technique for fragmentation testing

Automatic rifle was modified for remote, single-shot use. To simulate statistically--determined fragment size from rocket-motor casing blunt-nosed bullet was made of same alloy. Cartridge was loaded with enough powder to make bullet reach target at same estimated velocity as shrapnel from rocket casing.

Smith, T. H., III↗

Precision controllability of the YF-17 airplane

A flying qualities evaluation conducted on the YF-17 airplane permitted assessment of its precision controllability in the transonic flight regime over the allowable angle of attack range. The precision controllability (tailchase tracking) study was conducted in constant-g and windup turn tracking maneuvers with the command augmentation system (CAS) on, automatic maneuver flaps, and the caged pipper gunsight depressed 70 mils. This study showed that the YF-17 airplane tracks essentially as well at 7 g's to 8 g's as earlier fighters did at 4 g's to 5 g's before they encountered wing rock. The pilots considered the YF-17 airplane one of the best tracking airplanes they had flown. Wing rock at the higher angles of attack degraded tracking precision, and lack of control harmony made precision controllability more difficult. The revised automatic maneuver flap schedule incorporated in the airplane at the time of the tests did not appear to be optimum. The largest tracking errors and greatest pilot workload occurred at high normal load factors at low angles of attack. The pilots reported that the high-g maneuvers caused some tunnel vision and that they found it difficult to think clearly after repeated maneuvers.

Sisk, T. R.↗

NASA Tech Briefs, April 2005

Gas-Tolerant Device Senses Electrical Conductivity of Liquid Nanoactuators Based on Electrostatic Forces on Dielectrics Replaceable Microfluidic Cartridges for a PCR Biosensor CdZnTe Image Detectors for Hard-X-Ray Telescopes High-Aperture-Efficiency Horn Antenna Full-Circle Resolver-to-Linear-Analog Converter Continuous, Full-Circle Arctangent Circuit Advanced Three-Dimensional Display System Automatic Focus Adjustment of a Microscope Topics covered include: FastScript3D - A Companion to Java 3D; Generating Mosaics of Astronomical Images; Simulating Descent and Landing of a Spacecraft; Simulating Vibrations in a Complex Loaded Structure; Rover Sequencing and Visualization Program; Software Template for Instruction in Mathematics; Support for User Interfaces for Distributed Systems; Nanostructured MnO2-Based Cathodes for Li-Ion/Polymer Cells; Multi-Layer Laminated Thin Films for Inflatable Structures; Two-Step Laser Ranging for Precise Tracking of a Spacecraft; Growing Aligned Carbon Nanotubes for Interconnections in ICs; Multilayer Composite Pressure Vessels; Texturing Blood-Glucose-Monitoring Optics Using Oxygen Beams; Fault-Tolerant Heat Exchanger; Atomic Clock Based on Opto-Electronic Oscillator; Microfocus/Polycapillary-Optic Crystallographic X-Ray Sys; Depth-Penetrating Luminescence Thermography of Thermal- Barrier Coatings; One-Dimensional Photonic Crystal Superprisms; Measuring Low-Order Aberrations in a Segmented Telescope; Mapping From an Instrumented Glove to a Robot Hand; Application of the Hilbert-Huang Transform to Financial Data; Optimizing Parameters for Deep-Space Optical Communication; and Low-Shear Microencapsulation and Electrostatic Coating.

Source record↗

NV Energy Large-Scale Photovoltaic Integration Study: Intra-Hour Dispatch and AGC Simulation

The uncertainty and variability with photovoltaic (PV) generation make it very challenging to balance power system generation and load, especially under high penetration cases. Higher reserve requirements and more cycling of conventional generators are generally anticipated for large-scale PV integration. However, whether the existing generation fleet is flexible enough to handle the variations and how well the system can maintain its control performance are difficult to predict. The goal of this project is to develop a software program that can perform intra-hour dispatch and automatic generation control (AGC) simulation, by which the balancing operations of a system can be simulated to answer the questions posed above. The simulator, named Electric System Intra-Hour Operation Simulator (ESIOS), uses the NV Energy southern system as a study case, and models the system’s generator configurations, AGC functions, and operator actions to balance system generation and load. Actual dispatch of AGC generators and control performance under various PV penetration levels can be predicted by running ESIOS. With data about the load, generation, and generator characteristics, ESIOS can perform similar simulations and assess variable generation integration impacts for other systems as well. This report describes the design of the simulator and presents the study results showing the PV impacts on NV Energy real-time operations.

Energy↗

Proposal for a Vehicle Level Test Procedure to Measure Air Conditioning Fuel Use

The air-conditioning (A/C) compressor load significantly impacts the fuel economy of conventional vehicles and the fuel use/range of plug-in hybrid electric vehicles (PHEV). A National Renewable Energy Laboratory (NREL) vehicle performance analysis shows the operation of the air conditioner reduces the charge depletion range of a 40-mile range PHEV from 18% to 30% in a worst case hot environment. Designing for air conditioning electrical loads impacts PHEV and electric vehicle (EV) energy storage system size and cost. While automobile manufacturers have climate control procedures to assess A/C performance, and the U.S. EPA has the SCO3 drive cycle to measure indirect A/C emissions, there is no automotive industry consensus on a vehicle level A/C fuel use test procedure. With increasing attention on A/C fuel use due to increased regulatory activities and the development of PHEVs and EVs, a test procedure is needed to accurately assess the impact of climate control loads. A vehicle thermal soak period is recommended, with solar lamps that meet the SCO3 requirements or an alternative heating method such as portable electric heaters. After soaking, the vehicle is operated over repeated drive cycles or at a constant speed until steady-state cabin air temperature is attained. With this method, the cooldown and steady-state A/C fuel use are measured. This method can be run at either different ambient temperatures to provide data for the GREEN-MAC-LCCP model temperature bins or at a single representative ambient temperature. Vehicles with automatic climate systems are allowed to control as designed, while vehicles with manual climate systems are adjusted to approximate expected climate control settings. An A/C off test is also run for all drive profiles. This procedure measures approximate real-world A/C fuel use and assess the impact of thermal load reduction strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automatic Modeling of VVER-1000 Power Maneuvers

A special version of the IR code is described. The purpose of this code is to generate recommendations for the reactor operator when operating in a maneuvering regime, automate boron regulation, and study the maneuvering characteristics of VVER-1000 fuel loads. The results of modeling of operation in a daily load schedule are presented for the example of a stationary run of VVER-TOI. The impact of variation of the parameters of power maneuvers (run, operating time a reduced power, loading rate) on the boron regulation parameters is analyzed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Automatic computer subprogram selection from application program libraries

The program ALTLIB (ALTernate LIBrary) which allows a user access to an alternate subprogram library with a minimum effort is discussed. The ALTLIB program selects subprograms from an alternate library file and merges them with the user's program load file. Only subprograms that are called for (directly or indirectly) by the user's programs and that are available on the alternate library file will be selected. ALTLIB eliminates the need for elaborate control-card manipulations to add subprograms from a subprogram file. ALTLIB returns to the user his binary file and the selected subprograms in correct order for a call to the loader. The user supplies the alternate library file. Subprogram requests which are not satisfied from the alternate library file will be satisfied at load time from the system library.

Drozdowski, J. M.↗

Kinematically redundant robot manipulators

Research on control, design and programming of kinematically redundant robot manipulators (KRRM) is discussed. These are devices in which there are more joint space degrees of freedom than are required to achieve every position and orientation of the end-effector necessary for a given task in a given workspace. The technological developments described here deal with: kinematic programming techniques for automatically generating joint-space trajectories to execute prescribed tasks; control of redundant manipulators to optimize dynamic criteria (e.g., applications of forces and moments at the end-effector that optimally distribute the loading of actuators); and design of KRRMs to optimize functionality in congested work environments or to achieve other goals unattainable with non-redundant manipulators. Kinematic programming techniques are discussed, which show that some pseudo-inverse techniques that have been proposed for redundant manipulator control fail to achieve the goals of avoiding kinematic singularities and also generating closed joint-space paths corresponding to close paths of the end effector in the workspace. The extended Jacobian is proposed as an alternative to pseudo-inverse techniques.

Baillieul, J.↗

An algorithm for domain decomposition in finite element analysis

A simple and efficient algorithm is described for automatic decomposition of an arbitrary finite element domain into a specified number of subdomains for finite element and substructuring analysis in a multiprocessor computer environment. The algorithm is designed to balance the work loads, to minimize the communication among processors and to minimize the bandwidths of the resulting system of equations. Small- to large-scale finite element models, which have two-node elements (truss, beam element), three-node elements (triangular element) and four-node elements (quadrilateral element), are solved on the Convex computer to illustrate the effectiveness of the proposed algorithm. A FORTRAN computer program is also included.

Al-Nasra, M.↗

High capacity of lithium-sulfur batteries at low electrolyte/sulfur ratio enabled by an organosulfide containing electrolyte

We present that lithium-sulfur (Li-S) battery is a promising energy storage technology to replace lithium ion batteries for higher energy density and lower cost. Dissolution of lithium polysulfide intermediates in conventional Li-S electrolytes is known as one of the key technical barriers to the development of Li-S, because it promotes redistribution and irreversible deposition of Li 2 S, and also forces large amounts of electrolyte to be used, shortening cycling life and driving down cell energy density. Recently, dimethyl disulfide as a functional co-solvent has been demonstrated to show an alternate electrochemical reaction pathway for sulfur cathodes by the formation of dimethyl polysulfides and lithium organosulfides as intermediates and reduction products. In this work, comprehensive studies show that this new pathway not only provides high capacity but also enables excellent capacity retention through a built-in automatic discharge shutoff mechanism by tuning carbon/sulfur ratio in sulfur cathodes to reduce unfavorable Li 2 S formation. Furthermore, this new electrolyte system is also found to enable high capacity of high-sulfur-loading cathodes with low electrolyte/sulfur (E/S) ratios, such as a stable specific capacity of around 1000 mAh g -1 using a low electrolyte amount (i.e, E/S ratio of 5 mL g -1 ) and highsulfur-loading (4 mg cm -2 ) cathodes. This electrolyte system almost doubles the capacity obtained with conventional electrolytes under the same harsh conditions. In conclusion, these results highlight the practical potential of this electrolyte system to enable high-energy-density Li-S batteries.

25 ENERGY STORAGE↗

Ground heat exchanger design tool with rowwise placement of boreholes

Simulation-based design tools have been used since the late 1980s for designing ground heat exchangers (GHE) used with ground source heat pump (GSHP) systems. The ground heat exchanger simulations used in these tools rely on thermal response functions known as g-functions. Because of the significant computational burden in computing g-functions for even a single configuration, the design tools have relied on libraries of pre-computed g-functions. These g-functions were available for standard configuration shapes, such as lines, rectangles, open rectangles, L-shapes, and U-shapes. Standard shapes are often sub-optimal. For any building on a site, the available land may preclude use of a standard shape. For large GSHP systems with significantly imbalanced annual heat rejection and extraction loads, large rectangular fields may experience significant heat build-up (or heat draw-down) in the interior of the field. This paper describes a new ground heat exchanger design tool capable of automatically selecting and sizing both standard and irregular configurations. The focus of this paper is a method for creating, selecting and sizing irregular configurations where the available land area and "no-go" zones are described as irregular polygons.

Spitler, Jeffery↗

ERDA/NASA 100 kilowatt mod-o wind turbine operations and performance

The ERDA/NASA 100 kW Mod-0 wind turbine is operating at the NASA Plum Brook Station near Sandusky, Ohio. The operation of the wind turbine has been fully demonstrated and includes start-up, synchronization to the utility network, blade pitch control for control of power and speed, and shut-down. Also, fully automatic operation has been demonstrated by use of a remote control panel, 50 miles from the site, similar to what a utility dispatcher might use. The operation systems and experience with the wind turbine loads, electrical power and aerodynamic performance obtained from testing are described.

Thomas, R. L.↗

Three-Axis Load-Cell Assembly

Force-measuring device both sensitive and rugged. Load-cell assembly placed between manipulator and object being manipulated. Load cells measure forces on object almost directly, without interference by intervening manipulator forces. Developed for use with remote manipulator that bends cryogenic ducts. Device rugged and functions over wide range, having applications in automatic testing equipment, industrial robots, and force-measuring equipment.

Rewerts, G. R.↗

NASA automatic system for computer program documentation, volume 2

The DYNASOR 2 program is used for the dynamic nonlinear analysis of shells of revolution. The equations of motion of the shell are solved using Houbolt's numerical procedure. The displacements and stress resultants are determined for both symmetrical and asymmetrical loading conditions. Asymmetrical dynamic buckling can be investigated. Solutions can be obtained for highly nonlinear problems utilizing as many as five of the harmonics generated by SAMMSOR program. A restart capability allows the user to restart the program at a specified time. For Vol. 1, see N73-22129.

Simmons, D. B.↗

Automatic identification and quantification of dense microcracks in high-performance fiber-reinforced cementitious composites through deep learning-based computer vision

Highlights: • A method is presented to detect, locate, quantify, and visualize dense microcracks in HPFRCC. • Quantification of dense microcracks is realized using deep learning method for the first time. • The presented method uses deep learning models that are trained using a realistic dataset size. • The presented method has a high computation efficiency for identifying and quantifying cracks. • The presented method provides crack width with errors up to 50 μm and a R{sup 2} value of 0.984. High-performance fiber-reinforced cementitious composites (HPFRCCs) feature high mechanical strengths, crack resistance, and durability. Under excessive loading, HPFRCCs demonstrate dense microcracks that are difficult to identify using existing methods. This study presents a computer vision method for identification, quantification, and visualization of microcracks in HPFRCCs based on deep learning. The presented method integrates multiple deep learning models and computer vision techniques in a hierarchical architecture. The crack pattern (e.g., number, width, and spacing of cracks) are automatically determined from pictures without human intervention. This study shows that the presented method achieves an accuracy of 0.992 for crack detection and an accuracy finer than 50 μm (R{sup 2} > 0.984) for quantification of crack width when deep learning models are trained using only 200 pictures of HPFRCCs and 200 pictures of conventional concrete with incorporation of data augmentation. The presented method is expected to be also applicable to other materials featuring complex cracks.

36 MATERIALS SCIENCE↗