Search NASA⌕ Search

SEARCH · Search NASA

Results for “band”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Potential of Full-polarimetric P- and L-band Sar Data in Characterizing Post-fire Recovery of Arctic Tundra

We used the airborne full polarimetric L-band and P-band SAR (PolSAR) data collected from recent NASA ABoVE Arctic Boreal Vulnerability Experiment (ABoVE) airborne campaign to understand the sensitivity of longwave radar backscatter intensity and phase to post-fire recovery process of Arctic tundra. The 2007 Anaktuvuk River fire was used as a case study. At 10-year post-fire, we observed a strong increase (>~4 dB) in both the P- and L-band radar backscatter in the severely burned areas, in contrast to limited backscatter differences (VV, VH) between burned and unburned areas at C-band. The polarimetric target decomposition analysis indicated a general trend towards more random surface scattering, and strong increases of the double-bounce and volumetric scattering power at both P- and L-band in the burned areas. Large differences were also observed in the Pauli phase angle and the dominant-scattering-type Touzi phase angle between the burned and unburned areas. The above changes are likely caused by increasing surface roughness and microtopography due to thermokarst development and ice degradation, and increasing subsurface scattering due to an overall drier and deeper active layer in the burned areas

Miller, Charles E.↗

Single-Band Absolute Astrometry

The ionospheric contribution affects path delay. When simultaneous dual-band observations are used for absolute astrometry, the residual contribution of the ionosphere is at a level of several picoseconds. But there are two cases when we need to process single band group delays: a) some observations provided usable data only for one band; b) an entire experiment used only one band. I have developed a novel approach to utilize GNSS TEC maps to get the best solutions for these two cases and provide realistic estimates of residual errors. Applications of this technology is discussed. In particular, the impact of residual ionospheric path delays at K-band on estimates of source positions is quantitatively evaluated and conclusions about advantages and disadvantages of high frequency absolute astrometry are made.

Leonid Petrov↗

The Global L-Band Observatory for Water Cycle Studies (Glows)– SMAP continuity Mission

SMOS and SMAP radiometers have demonstrated the ability to monitor soil moisture and sea surface salinity and continue to provide high quality radiometric measurements to this day in extended mission operations. It is important to maintain data continuity for these science measurements. The proposed instrument concept (Global L-band active/passive Observatory for Water cycle Studies - GLOWS) will enable low-cost L-band data continuity (that includes both L-band radar and radiometer measurements). The objective of this project is to develop key instrument technology to enable L-band observations using an Earth Venture class satellite. Specifically, a new deployable reflectarray lens antenna is being developed that will enable a smaller EELV Secondary Payload Adapter (ESPA) Grande-class satellite mission to continue the L-band observations at SMAP and SMOS resolution and accuracy at substantially lower cost, size, and weight

SMAP↗

Single-Band VLBI Absolute Astrometry

The ionospheric path delay impacts single-band very long baseline interferometry (VLBI) group delays, which limits their applicability for absolute astrometry. I consider two important cases: when observations are made simultaneously in two bands, but delays in only one band are available for a subset of observations and when observations are made at one band design. I developed optimal procedures of data analysis for both cases using Global Navigation Satellite System (GNSS) ionosphere maps, provided a stochastic model that describes ionospheric errors, and evaluated their impact on source position estimates. I demonstrate that the stochastic model is accurate at a level of 15%. I found that using GNSS ionospheric maps as is introduces serious biases in estimates of declination and I developed a procedure that almost eliminates them. I found serendipitously that GNSS ionospheric maps have multiplicative errors and have to be scaled by 0.85 in order to mitigate the declination bias. A similar scale factor was found in comparison of the vertical total electron content from satellite altimetry against GNSS ionospheric maps. I favor interpretation of this scaling factor as a manifestation of the inadequacy of the thin shell model of the ionosphere. I showed that we are able to model the ionospheric path delay to the extent that no noticeable systematic errors emerge and we are able to assess adequately the contribution of the ionosphere-driven random errors on source positions. This makes single-band absolute astrometry a viable option that can be used for source position determination.

Radio astrometry↗

Mars 2020 Entry, Descent, and Landing as Observed by Radio Science Techniques at UHF and X-band Frequencies

On February 18, 2021, NASA’s Mars 2020 Rover “Perseverance” conducted the Entry, Descent, and Landing (EDL) sequence to land safely on the surface of Mars at Jezero Crater. Due to the criticality of the EDL sequence, redundant telecommunications strategies were utilized to observe the event. The rover transmitted an X-band (8.4 GHz) signal encoded with Multiple Frequency Shift Keying tones direct-to-Earth and a UHF (401.5 MHz) signal with 8 kbps encoded telemetry to orbiters, which relayed the signal back to Earth at X-band. NASA’s Deep Space Network complexes at Goldstone, California and Madrid, Spain received the direct-to-Earth X-band signal. Two of the largest steerable radio telescopes in the world, the 100-meter Green Bank Telescope in West Virginia and the Effelsberg 100-meter Radio Telescope in Germany also received the UHF carrier signal on Earth. During the EDL event, full spectrum recordings of the UHF and X-band signals were captured at these observatories using open-loop receivers. Real-time and post-processing signal analysis to determine power level, received frequency, and Doppler shift allowed determination of the spacecraft’s health and safety state during critical sequences, including event detection such as atmospheric entry, plasma blackouts, and parachute deployment. Simultaneous observations of the UHF and X-band radio links allow for redundancy in the event of a fault and greatly improve confidence in Doppler event detection.

Gladden, Roy↗

Molecules in Cool Stars: The A 2 Π − X 2 Σ + and the B 2 Σ + − X 2 Σ + Band Systems of CaCl

Cool red giant stars exhibit absorption bands of calcium monochloride (CaCl) in the optical region. In this work, the bands of CaCl corresponding to the A 2 Π − X 2 Σ + transition with v' ≤ 4 and v'' ≤ 4, and B 2 Σ + − X 2 Σ + transition with v' ≤ 2 and v'' ≤ 2 are rotationally analyzed with PGOPHER, a multipurpose program for simulating and fitting molecular spectra. All bands were analyzed using high-resolution absorption spectra collected at the National Solar Observatory in 1985, calibrated with atomic lines from a high-resolution emission spectrum obtained in a separate hollow cathode experiment. The results are compared with previous laser-induced fluorescence measurements. Overall, the accuracy of spectroscopic constants for the A2Π and B2Σ+ states is improved. Scaled transition dipole moment calculations were used to obtain line strengths. Line lists are provided with Einstein A coefficients and oscillator strengths, which can be used to determine CaCl stellar abundances. Additionally, isotope splittings allowed us to estimate band origins for the 40 Ca 37 Cl isotopologue based on band-head positions.

Léo Lavy↗

Progress in Time-Series Soil Moisture Retrieval Using L- and S-Band Radar Backscatter

L- and S-band observations from NASA's Passive/Active L/S band (PALS) sensor from the SMEX02 campaign were used to estimate soil moisture. The retrieval process is based on the “alpha approximation” method. This method utilizes a time-series of normalized radar backscatter measurements as well as ancillary information to estimate soil moisture over the Walnut Creek watershed. The resulting retrieved soil moistures are compared to in-situ soil moisture measurements at multiple test sites within the watershed. The calculations show reasonable results for both L- and S-band and provide further insight into the use of L- and S-bands for the upcoming NASA/ISRO mission.

Soil moisture↗

Using parallel banded linear system solvers in generalized eigenvalue problems

Subspace iteration is a reliable and cost effective method for solving positive definite banded symmetric generalized eigenproblems, especially in the case of large scale problems. This paper discusses an algorithm that makes use of two parallel banded solvers in subspace iteration. A shift is introduced to decompose the banded linear systems into relatively independent subsystems and to accelerate the iterations. With this shift, an eigenproblem is mapped efficiently into the memories of a multiprocessor and a high speedup is obtained for parallel implementations. An optimal shift is a shift that balances total computation and communication costs. Under certain conditions, we show how to estimate an optimal shift analytically using the decay rate for the inverse of a banded matrix, and how to improve this estimate. Computational results on iPSC/2 and iPSC/860 multiprocessors are presented.

DISTRIBUTED MEMORY MULTIPROCES↗

Use of the 37-38 GHz and 40-40.5 GHz Ka-bands for Deep Space Communications

This paper covers a wide variety of issues associated with the implementation and use of these frequency bands for deep space communications. Performance issues, such as ground station pointing stability, ground antenna gain, antenna pattern, and propagation effects such as due to atmospheric, charged-particle and space loss at 37 GHz, will be addressed in comparison to the 32 GHz Ka-band deep space allocation. Issues with the use of and competition for this spectrum also will be covered. The state of the hardware developed (or proposed) for operating in this frequency band will be covered from the standpoint of the prospects for achieving higher data rates that could be accommodated in the available bandwidth. Hardware areas to be explored include modulators, digital-to-analog converters, filters, power amplifiers, receivers, and antennas. The potential users of the frequency band will be explored as well as their anticipated methods to achieve the potential high data rates and the implications of the competition for bandwidth.

telecommunications↗

A Ka-Band Celestial Reference Frame with Applications to Deep Space Navigation

The Ka-band radio spectrum is now being used for a wide variety of applications. This paper highlights the use of Ka-band as a frequency for precise deep space navigation based on a set of reference beacons provided by extragalactic quasars which emit broadband noise at Ka-band. This quasar-based celestial reference frame is constructed using X/Ka-band (8.4/32 GHz) from fifty-five 24-hour sessions with the Deep Space Network antennas in California, Australia, and Spain. We report on observations which have detected 464 sources covering the full 24 hours of Right Ascension and declinations down to -45 deg. Comparison of this X/Ka-band frame to the international standard S/X-band (2.3/8.4 GHz) ICRF2 shows wRMS agreement of approximately 200 micro-arcsec in alpha cos(delta) and approximately 300 micro-arcsec in delta. There is evidence for systematic errors at the 100 micro-arcsec level. Known errors include limited SNR, lack of instrumental phase calibration, tropospheric refraction mis-modeling, and limited southern geometry. The motivation for extending the celestial reference frame to frequencies above 8 GHz is to access more compact source morphology for improved frame stability and to support spacecraft navigation for Ka-band based NASA missions.

k-band↗

Evaluation of Spaceborne L-band Radiometer Measurements for Terrestrial Freeze/Thaw Retrievals in Canada

The landscape freeze/thaw (FT) state has an important impact on the surface energy balance, carbon fluxes, and hydrologic processes; the timing of spring melt is linked to active layer dynamics in permafrost areas. L-band (1.4 GHz) microwave emission could allow the monitoring of surface state dynamics due to its sensitivity to the pronounced permittivity difference between frozen and thawed soil. The aim of this paper is to evaluate the performance of both Aquarius and Soil Moisture and Ocean Salinity (SMOS) L-band passive microwave measurements using a polarization ratio-based algorithm for landscape FT monitoring. Weekly L-band satellite observations are compared with a large set of reference data at 48 sites across Canada spanning three environments: tundra, boreal forest, and prairies. The reference data include in situ measurements of soil temperature (Tsoil) and air temperature (Tair), and Moderate Resolution Imaging Spectroradiometer (MODIS) land surface temperature (LST) and snow cover area (SCA) products. Results show generally good agreement between Lband FT detection and the surface state estimated from four reference datasets. The best apparent accuracies for all seasons are obtained using Tair as the reference. Aquarius radiometer 2 (incidence angle of 39.6) data gives the best accuracies (90.8), while for SMOS the best results (87.8 of accuracy) are obtained at higher incidence angles (55- 60). The FT algorithm identifies both freeze onset and end with a delay of about one week in tundra and two weeks in forest and prairies, when compared to Tair. The analysis shows a stronger FT signal at tundra sites due to the typically clean transitions between consistently frozen and thawed conditions (and vice versa) and the absence of surface vegetation. Results in the prairies were poorer because of the influence of vegetation growth in summer (which decreases the polarization ratio) and the high frequency of ephemeral thaw events during winter. Freeze onset and end maps created from the same algorithm applied to SMOS and Aquarius measurements characterize similar FT patterns over Canada. This study shows the potential of using L-band spaceborne observations for FT monitoring, but underlines some limitations due to ice crusts in the snowpack, liquid water content in snow cover during the spring freeze to thaw transition, and vegetation growth.

soil freeze/thaw↗

Design and Validation of High Date Rate Ka-Band Software Defined Radio for Small Satellite

The Design and Validation of High Date Rate Ka- Band Software Defined Radio for Small Satellite project will develop a novel Ka-band software defined radio (SDR) that is capable of establishing high data rate inter-satellite links with a throughput of 500 megabits per second (Mb/s) and providing millimeter ranging precision. The system will be designed to operate with high performance and reliability that is robust against various interference effects and network anomalies. The Ka-band radio resulting from this work will improve upon state of the art Ka-band radios in terms of dimensional size, mass and power dissipation, which limit their use in small satellites.

Small satellites↗

Early Calibration and Performance Assessments of NOAA-20 VIIRS Thermal Emissive Bands

The Visible Infrared Imaging Radiometer Suite (VIIRS) sensor aboard the NOAA-20 (previously JPSS-1) spacecraft has successfully operated since its launch in November, 2017. Similar to the first VIIRS instrument on the Suomi-NPP spacecraft, data is collected in 22 spectral bands that are calibrated by a set of onboard calibrators. This paper provides an overview of the NOAA-20 VIIRS on-orbit operation and calibration, with a particular focus on the thermal emissive bands (TEBs). Results presented in this paper include the on-orbit changes in the TEB spectral band responses, detector noise characterization, and key calibration parameters, such as the non-linear coefficients derived from the blackbody warm-up cool-down cycle. Other issues, such as the early mission long-wave infrared (LWIR) response degradation due to icing on the dewar window, and their impact on sensor calibration are also discussed. Since launch, the VIIRS instrument temperature has been stable to within ± 0.8K and the cold focal plane temperatures are well controlled with variations less than 40 mK. With the exception of the early degradation observed in the LWIR bands, the TEB gains have been stable to within 0.04% (except I5 at 0.07%). Based on the current performance, VIIRS is expected to meet its calibration requirements throughout its design lifetime.

NEdT↗

Early Calibration and Performance Assessments of NOAA-20 VIIRS Thermal Emissive Bands

The Visible Infrared Imaging Radiometer Suite (VIIRS) sensor aboard the NOAA-20 (previously JPSS-1) spacecraft has successfully operated since its launch in November, 2017. Similar to the rst VIIRS instrument on the Suomi-National Polar-orbiting Partnership (SNPP) spacecraft, the data are collected in 22 spectral bands that are calibrated by a set of onboard calibrators. This paper provides an overview of the NOAA-20 VIIRS on-orbit operation and calibration, with a particular focus on the thermal emissive bands (TEBs). The results presented in this paper include the on-orbit changes in the TEB spectral band responses, detector noise characterization, and key calibration parameters, such as the nonlinear coefcients derived from the blackbody warm-up cool-down cycles. Other issues, such as the early mission long-wave infrared (LWIR) response degradation due to icing on the dewar window, and their impact on sensor calibration are also discussed. Since launch, the VIIRS instrument temperature has been stable to within ±0.8 K and the cold focal plane temperatures are well controlled with variations less than 40 mK. With the exception of the early degradation observed in the LWIR bands, the TEB gains have been stable to within 0.04% (except I5 at 0.07%). Based on the current performance, VIIRS is expected to meet its calibration requirements throughout its design lifetime.

noise equivalent 25 differential temperature (NEdT↗

Measuring Crosstalk in MODIS Spectral Bands On-orbit Using the SRCA

Near-identical MODIS instruments launched on-board the Terra and Aqua spacecraft in 1999 and 2002, respectively. Each MODIS instrument has36 spectral bands covering 0.41 to 14.2μm mounted among four focal plane assemblies, along with a series of on-board calibrators (OBCs) used to characterize the instrument performance on-orbit. One such OBC is the Spectro-radiometric Calibration Assembly (SRCA), which is a multi-function calibrator, able to provide calibration sources to measure spatial, spectral, or radiometric properties of the MODIS bands depending on its configuration. The MODIS instrument performance, including measurements of the signal cross-contamination (crosstalk) between bands, was measured on-orbit during early-mission characterization for both instruments. This crosstalk test used the SRCA in its spatial mode while utilizing the thin slit, which is normally used for spectral calibrations. A similar crosstalk test was recently performed for Terra MODIS. Since the Terra safe mode event in 2016, the PVLWIR bands specifically (6.7-9.7μm) have shown increased influence from crosstalk. The process involved in preparing and performing this crosstalk test is included in this work, as well as the findings from the recent and previous SRCA-based crosstalk characterizations.

MODIS↗

Ka-Band Propagation Research Using ACTS

The Ka band (20-30 GHz) is being explored as a communications band because of congestion in presently used bands. The Advanced Communications Technology Satellite (ACTS) is being used to test use of the Ka band and how to deal with possible problems (e.g., rain attenuation due to shorter wavelengths).

propagation↗

Comparison of the MODIS and VIIRS Thermal Emissive Band Radiometric Calibration

Moderate Resolution Imaging Spectroradiometer (MODIS) and Visible Infrared Imaging Radiometer Suite (VIIRS) are major instruments for Earth science observations.Nearly 40 MODIS scientific products and a wide range of VIIRS environmental data records are produced using their global observations. The consistency of the MODIS and VIIRS calibrated data is important for the study of Earth science. This article assesses the calibration consistency of the Aqua MODIS and VIIRS thermal emissive band (TEB) data. To remove the impact of the mismatched relative spectral response (RSR) on the comparisons, the simultaneous nadir observation data from the cross-track infrared sounder (CrIS) and the infrared atmospheric sounding interferometer (IASI) are used as references in two different methods to independently verify the consistency. The comparisons of the MODIS and VIIRS TEB calibrated data show that the brightness temperature (BT) differences for comparable bands between MODIS and VIIRS are in general within 0.2 K for BT larger than 230 K. The differences of all comparable MODIS and VIIRS TEBs are consistent over time. MODIS measurements agree better with N20 VIIRS than with Suomi National Polar-orbiting Partnership (S-NPP) VIIRS. The S-NPP VIIRS measurements are higher than N20 VIIRS, within 0.1 Kfor long-wave infrared (LWIR) bands and 0.3 K for band M13.

Calibration↗

Terra MODIS Sees Solar Eclipses: Analysis of Reflective Solar Band Response at Multiple Radiance Levels

The MODIS imaging spectroradiometer instruments on-board NASA's Terra and Aqua satellites have 20 reflective solar bands (RSB) covering a wavelength range from 400 to 2200 nm. Radiance is calculated from processing raw signals with background, temperature, and electronic contamination corrected. Measured gain is calibrated with a fully Sunlit solar diffuser (SD) at a stable radiance level, considering a slowly changing SD reflectance degradation. These measurements provide time-dependent gain adjustment factors, and the calibration assumes a linear response for each band and detector. Hence, an analysis of the dependence on different radiance levels is warranted. The MODIS design has no mechanism for varying radiance levels, except for an attenuator screen. However, it has been in static configuration for Terra since mid-2003. An external source of radiance attenuation can be utilized during solar eclipse events, while maintaining high stability and accuracy of solar calibration standards. Due to its long mission lifetime, Terra has seen several Sun-Moon near-conjunction events when it coincides with the orbit path where the SD is directly illuminated. As of August 2020, we have identified 7 viable partial solar eclipses in the Terra mission data. We will discuss several results of our study, including comparison of measured SD signal to predicted radiance reduction based on a solar disk radiance model; nominal and outlier behavior as a function of bands, detectors, and mirror-sides; and comparison with other data sets. Our main conclusion from this study is that there is no notable correlation of detector-dependent trend with radiance level for most RSB bands.

Terra↗