Search NASA⌕ Search

SEARCH · Search NASA

Results for “baseline performance reference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Day-ahead continuous double auction-based peer-to-peer energy trading platform incorporating trading losses and network utilisation fee

Integration of distributed energy resources, such as photovoltaic solar (PV), introduces new opportunities to establish local energy market frameworks to improve renewable energy utilisation in residential sectors. Such peer-to-peer (P2P) energy trading refers to a local market structure where customers (and prosumers) interact to share excess PV generation to enhance the individual and community social welfare. In this work, a day-ahead continuous double auction (CDA)-based P2P market structure considering network losses and network utilisation fees was designed. Day-ahead PV energy is modelled using fractional integral polynomials and the output is forecasted using an autoregressive integrated moving average model for each market interval. Based on the customer load and excess PV energy, the CDA market is cleared using a bid/ask matching mechanism. The performance of the P2P market was evaluated by computing different welfare metrics while analysing the effect of network constraints. The results show that the designed CDA-based P2P market structure increases the social welfare of all participants by an average of 17.75% compared to the baseline for the presented cases. Moreover, the impact of the forecasting error between the day-ahead and real-time market was also quantified.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DNABERT-S: pioneering species differentiation with species-aware DNA embeddings

SUMMARY: We introduce DNABERT-S, a tailored genome model that develops species-aware embeddings to naturally cluster and segregate DNA sequences of different species in the embedding space. Differentiating species from genomic sequences (i.e. DNA and RNA) is vital yet challenging, since many real-world species remain uncharacterized, lacking known genomes for reference. Embedding-based methods are therefore used to differentiate species in an unsupervised manner. DNABERT-S builds upon a pre-trained genome foundation model named DNABERT-2. To encourage effective embeddings to error-prone long-read DNA sequences, we introduce Manifold Instance Mixup (MI-Mix), a contrastive objective that mixes the hidden representations of DNA sequences at randomly selected layers and trains the model to recognize and differentiate these mixed proportions at the output layer. We further enhance it with the proposed Curriculum Contrastive Learning (C2LR) strategy. Empirical results on 28 diverse datasets show DNABERT-S's effectiveness, especially in realistic label-scarce scenarios. For example, it identifies twice more species from a mixture of unlabeled genomic sequences, doubles the Adjusted Rand Index (ARI) in species clustering, and outperforms the top baseline's performance in 10-shot species classification with just a 2-shot training. AVAILABILITY AND IMPLEMENTATION: Model, codes, and data are publically available at https://github.com/MAGICS-LAB/DNABERT_S.

Zhou, Zhihan↗

Cost and Performance Baseline for Fossil Energy Plants Volume 3: Low Rank Coal and Natural Gas to Electricity

This report presents an independent assessment of the cost and performance of select fossil energy power systems—pulverized coal (PC), circulating fluidized bed (CFB), and natural gas combined cycle (NGCC) plants—using a systematic, transparent technical and economic approach. This is Volume 3 of a five-volume series, which comprise the following reports: Volume 1: Bituminous Coal and Natural Gas to Electricity; Volume 2: Coal to Synthetic Natural Gas and Ammonia (Various Coal Ranks); Volume 3: Low Rank Coal and Natural Gas to Electricity; Volume 4: Bituminous Coal to Liquid Fuels; and Volume 5: Natural Gas Electricity Generating Units for Flexible Operation. The cost and performance of fossil fuel-based generation technologies represented in this report (and the series at large) are important inputs to assessments and determinations of technology combinations to be utilized to meet the projected demands of future power markets. In addition to informing technology comparisons, the reference plant configurations found in this report provide perspective for regulators and policy makers. From a research and development perspective, this report is used to assess goals and metrics and to provide a consistent basis for comparing developing technologies.

20 FOSSIL-FUELED POWER PLANTS↗

SU-E-T-211: Comparison of Seven New TrueBeam Linacs with Enhanced Beam Data Conformance Using a Beam Comparison Software Tool

Purpose: To develop an independent software tool to assist in commissioning linacs with enhanced beam conformance, as well as perform ongoing QA for dosimetrically equivalent linacs. Methods: Linac manufacturers offer enhanced beam conformance as an option to allow for clinics to complete commissioning efficiently, as well as implement dosimetrically equivalent linacs. The specification for enhanced conformance includes PDD as well as profiles within 80% FWHM. Recently, we commissioned seven Varian TrueBeam linacs with enhanced beam conformance. We developed a software tool in Visual Basic to allow us to load the reference beam data and compare our beam data during commissioning to evaluate enhanced beam conformance. This tool also allowed us to upload our beam data used for commissioning our dosimetrically equivalent beam models to compare and tweak each of our linac beams to match our modelled data in Varian’s Eclipse TPS. This tool will also be used during annual QA of the linacs to compare our beam data to our baseline data, as required by TG-142. Results: Our software tool was used to check beam conformance for seven TrueBeam linacs that we commissioned in the past six months. Using our tool we found that the factory conformed linacs showed up to 3.82% difference in their beam profile data upon installation. Using our beam comparison tool, we were able to adjust the energy and profiles of our beams to accomplish a better than 1.00% point by point data conformance. Conclusion: The availability of quantitative comparison tools is essential to accept and commission linacs with enhanced beam conformance, as well as to beam match multiple linacs. We further intend to use the same tool to ensure our beam data conforms to the commissioning beam data during our annual QA in keeping with the requirements of TG-142.

43 PARTICLE ACCELERATORS↗

Ion Storage with the High Performance Antiproton Trap (HiPAT)

The matter antimatter reaction represents the densest form of energy storage/release known to modern physics: as such it offers one of the most compact sources of power for future deep space exploration. To take the first steps along this path, NASA-Marshall Space Flight Center is developing a storage system referred to as the High Performance Antiproton Trap (HiPAT) with a goal of maintaining 10(exp 12) particles for up to 18 days. Experiments have been performed with this hardware using normal matter (positive hydrogen ions) to assess the device's ability to hold charged particles. These ions are currently created using an electron gun method to ionize background gas; however, this technique is limited by the quantity that can be captured. To circumvent this issue, an ion source is currently being commissioned which will greatly increase the number of ions captured and more closely simulate actual operations expected at an antiproton production facility. Ions have been produced, stored for various time intervals, and then extracted against detectors to measure species, quantity and energy. Radio frequency stabilization has been tested as a method to prolong ion lifetime: results show an increase in the baseline 1/e lifetime of trapped particles from hours to days. Impurities in the residual background gas (typically carbon-containing species CH4, CO, CO2, etc.) present a continuing problem by reducing the trapped hydrogen population through the mechanism of ion charge exchange.

Martin, James↗

Autonomous Navigation of a Lunar Relay Using GNSS and Other Measurements

Many of the highest priority destinations at the Moon lack a continuous view of Earth, such as the lunar poles or lunar far side. Exploration of these sites will require spacecraft in cislunar space to relay communications and provide position, navigation, and timing (PNT) services. Accurate knowledge of relay position, velocity, and time is essential to these services. This paper describes a concept for a PNT Instrument being developed for the Lunar Communications Relay and Navigation Systems (LCRNS) Project. The instrument is intended as a payload that would enable autonomous, on-board, real-time navigation and timing using Global Navigation Satellite System (GNSS), optical navigation, and one-way measurements from Earth-based ground stations. Hardware-in-the-loop simulations using flight software are used to realistically characterize performance on hardware platforms with a path to flight. These results provide preliminary validation of the proposed PNT Instrument, demonstrate the benefits of augmenting GNSS with other measurements, and serve as an insightful reference for the design of future lunar missions, including those that will operate within the LunaNet framework of standards. This instrument concept relies on several technologies developed at NASA Goddard Space Flight Center (GSFC). For GNSS observables, the instrument relies on the high-altitude NavCube 3 mini (NC3m) GNSS receiver specifically designed for cislunar applications. The autoNGC system, which consists of flight software and a hardware platform, is responsible for fusing the observables using its extended Kalman filter, the Goddard Enhanced Onboard Navigation System (GEONS). Optical navigation observables are processed within autoNGC (“autonomous Navigation, Guidance, and Control”) using the Goddard Image Analysis & Navigation Tool (GIANT) which is also responsible for simulating high-fidelity images for test and analysis. In addition to describing the PNT Instrument and its components, the paper will present predicted performance based on simulation results. As a baseline, it will present GNSS-only hardware-in-the loop results using a NC3m test unit to process Spirent-simulated GPS signals in a potential lunar relay trajectory: a 12-hour elliptical frozen lunar orbit (ELFO). GEONS then processes the GPS pseudorange and time differenced carrier phase measurements to estimate and propagate the relay state (position, velocity, and time). These results extend previously published work that showed preliminary ELFO performance. Previous work has shown the importance of other measurement types, so additional simulations are performed which augment GNSS with ground station observables and several methods of optical navigation, including celestial navigation, limb-finding (e.g., observations of the lunar horizon), and terrain relative navigation (TRN). TRN involves correlating simulated predicted images of the lunar surface with actual imagery; misalignments of landmarks identified in each image are translated into relay state updates. TRN is valuable as a measurement of the relay’s state relative to the Moon, especially during GNSS outages or after maneuvers. One-way Pseudorange and Doppler measurements from Earth-based ground stations are also simulated. The full set of observables is processed using autoNGC. These simulations make use of autoNGC and NC3m test units, a lab atomic clock, and a pulse-per-second (PPS) generation and distribution system. This combination of subsystems, and the hardware platforms used in this analysis, represents a PNT Instrument that could be flown on a lunar relay. Results from the hardware-in-the-loop simulations presented in this paper provide a preliminary assessment of the achievable navigation performance of this instrument concept. PNT Instrument performance is compared to the GPS-only performance, and a discussion is provided on the apparent merits and challenges of each measurement type.

Ben Ashman↗

Phantom and Clinical Study of Differences in Cone Beam Computed Tomographic Registration When Aligned to Maximum and Average Intensity Projection

Purpose: To determine whether maximum or average intensity projection (MIP or AIP, respectively) reconstructed from 4-dimensional computed tomography (4DCT) is preferred for alignment to cone beam CT (CBCT) images in lung stereotactic body radiation therapy. Methods and Materials: Stationary CT and 4DCT images were acquired with a target phantom at the center of motion and moving along the superior–inferior (SI) direction, respectively. Motion profiles were asymmetrical waveforms with amplitudes of 10, 15, and 20 mm and a 4-second cycle. Stationary CBCT and dynamic CBCT images were acquired in the same manner as stationary CT and 4DCT images. Stationary CBCT was aligned to stationary CT, and the couch position was used as the baseline. Dynamic CBCT was aligned to the MIP and AIP of corresponding amplitudes. Registration error was defined as the SI deviation of the couch position from the baseline. In 16 patients with isolated lung lesions, free-breathing CBCT (FBCBCT) was registered to AIP and MIP (64 sessions in total), and the difference in couch shifts was calculated. Results: In the phantom study, registration errors were within 0.1 mm for AIP and 1.5 to 1.8 mm toward the inferior direction for MIP. In the patient study, the difference in the couch shifts (mean, range) was insignificant in the right-left (0.0 mm, ≤1.0 mm) and anterior–posterior (0.0 mm, ≤2.1 mm) directions. In the SI direction, however, the couch position significantly shifted in the inferior direction after MIP registration compared with after AIP registration (mean, −0.6 mm; ranging 1.7 mm to the superior side and 3.5 mm to the inferior side, P=.02). Conclusions: AIP is recommended as the reference image for registration to FBCBCT when target alignment is performed in the presence of asymmetrical respiratory motion, whereas MIP causes systematic target positioning error.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Baseline estimation from simultaneous satellite laser tracking

Simultaneous Range Differences (SRDs) to Lageos are obtained by dividing the observing stations into pairs with quasi-simultaneous observations. For each of those pairs the station with the least number of observations is identified, and at its observing epochs interpolated ranges for the alternate station are generated. The SRD observables are obtained by subtracting the actually observed laser range of the station having the least number of observations from the interpolated ranges of the alternate station. On the basis of these observables semidynamic single baseline solutions were performed. The aim of these solutions is to further develop and implement the SRD method in the real data environment, to assess its accuracy, its advantages and disadvantages as related to the range dynamic mode methods, when the baselines are the only parameters of interest. Baselines, using simultaneous laser range observations to Lageos, were also estimated through the purely geometric method. These baselines formed the standards the standards of comparison in the accuracy assessment of the SRD method when compared to that of the range dynamic mode methods. On the basis of this comparison it was concluded that for baselines of regional extent the SRD method is very effective, efficient, and at least as accurate as the range dynamic mode methods, and that on the basis of a simple orbital modeling and a limited orbit adjustment. The SRD method is insensitive to the inconsistencies affecting the terrestrial reference frame and simultaneous adjustment of the Earth Rotation Parameters (ERPs) is not necessary.

Dedes, George C.↗

ComStock Measure Scenario Documentation: Standard Performance Heat Pump Rooftop Unit With New Windows

Building on a 3-year effort to calibrate and validate the U.S. Department of Energy's ResStock (TM) and ComStock (TM) models, this work produces national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual energy consumption (at subhourly resolution) of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. The goal of this work is to develop energy efficiency and demand flexibility end-use load shapes that cover high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to various "what-if" scenarios that can be applied to buildings. An end-use savings shape is the difference in energy consumption between a baseline building (or collection of buildings) and a building with an energy efficiency or demand flexibility measure applied. It results in a time-series profile broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step, as well as annual aggregations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nonlinear Dynamic Inversion Baseline Control Law: Flight-Test Results for the Full-scale Advanced Systems Testbed F/A-18 Airplane

A model reference nonlinear dynamic inversion control law has been developed to provide a baseline controller for research into simple adaptive elements for advanced flight control laws. This controller has been implemented and tested in a hardware-in-the-loop simulation and in flight. The flight results agree well with the simulation predictions and show good handling qualities throughout the tested flight envelope with some noteworthy deficiencies highlighted both by handling qualities metrics and pilot comments. Many design choices and implementation details reflect the requirements placed on the system by the nonlinear flight environment and the desire to keep the system as simple as possible to easily allow the addition of the adaptive elements. The flight-test results and how they compare to the simulation predictions are discussed, along with a discussion about how each element affected pilot opinions. Additionally, aspects of the design that performed better than expected are presented, as well as some simple improvements that will be suggested for follow-on work.

Miller, Christopher J.↗

ASSESSMENT OF MULTIPHASE CFD WITH ZERO CLOSURE MODEL FOR BOILING WATER REACTOR FUEL ASSEMBLIES

Extension of existing boiling closures to the high void fraction conditions of BWRs is one of challenges for M-CFD applications. This paper presents the assessment of an Eulerian M-CFD model with Zero closure model that has been specifically designed for two-phase flow and heat transfer applications in BWR fuel assemblies. The baseline Zero closure aims at including the simplest and most robust representation of the key physical mechanisms, rather than aiming at absolute accuracy of the predictions. The capabilities of M-CFD with Zero were evaluated against the international OECD/NRC BFBT benchmark data through the comparative analyses of local void fraction, sub-channel void fraction error and exit quality. INL high performance computing system has been employed to demonstrate the scalability of the M-CFD application to nuclear reactor fuel assemblies. The M-CFD simulation results show a good agreement with the experimental data for both quantitative and qualitative results, with the highest uncertainty being observed in the prediction of the local void fraction profile at low void fraction condition. This paper presents a recent view of the best practices for M-CFD of BWR fuel assemblies to provide a useful reference to identify and overcome common challenges in the applications of M-CFD tools. We provide recommendations for geometric modeling, mesh generation and solver configurations to optimize the methodology application.

97 MATHEMATICS AND COMPUTING↗

Characterization of injection and confinement improvement through impurity induced profile modifications on the Wendelstein 7-X stellarator

Pulsed injections of boron carbide granules into Wendelstein 7-X stellarator (W7-X) plasmas transiently increase the plasma stored energy and core ion temperatures above the reference W7-X experimental programs by up to 30%. In a series of 4 MW electron cyclotron resonance heating experiments, the PPPL Probe Mounted Powder Injector provided 50 ms bursts of 100 μm granules every 350 ms at estimated quantities ranging from approximately 1 mg/pulse to over 30 mg/pulse. For each injection, the stored energy was observed to initially drop and the radiated power transiently increased, while the radial electron density profile rose at the edge as material was assimilated. Once the injected boron carbide was fully absorbed, the density rise transitioned to the core while the stored energy increased above the previous baseline level by an amount linearly correlated with the injection quantity. During the injection, the ion temperature gradient steepened with peak core ion temperatures observed to increase from a nominal 1.7 keV to over 2.6 keV for the largest injection amounts. Enhanced performance is accompanied by a reversal of the radial electric field at ρ < 0.3, indicating that the core transport has switched to the ion root. These observations are suggestive of a change in transport and provide further evidence that externally induced profile modifications provide a possible path to enhanced W7-X performance metrics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advanced Drying Cycle Simulator Thermal Response to Commercial Drying Conditions

The purpose of this report is to document updates on testing of the apparatus built to simulate commercial drying procedures for spent nuclear fuel at the Nuclear Energy Work Complex at Sandia National Laboratories. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system during subsequent storage and disposal. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates well-designed investigations of drying process efficacy and water retention that incorporate relevant physics and well-controlled boundary conditions. This report documents testing updates for the Advanced Drying Cycle Simulator (ADCS). This apparatus was built to simulate commercial drying procedures and quantify the amount of residual water remaining in a pressurized water reactor (PWR) fuel assembly after drying. The ADCS was constructed with a prototypic 17×17 PWR fuel skeleton and waterproof heater rods to simulate decay heat. These waterproof heaters are the next generation design to heater rods developed and tested at Sandia National Laboratories in FY20. This report describes preliminary testing of the ADCS through measurement and analysis of the thermal response of the system to a subset of commercial drying conditions that exclude the introduction of water, namely simulated decay heats and pressures relevant to commercial drying. This test series, referred to as a “dry” test series in this report, spans three uniform waterproof heater rod powers (representing spent fuel decay heats), four helium fill pressures, and six vacuum levels. This test series was conducted to cover the range of expected ADCS testing conditions for upcoming “wet” testing, where water will be introduced and a simulated commercial drying cycle will be performed. The dry test conditions were derived from the commercial drying conditions seen in the High Burnup Demonstration and the vacuum drying conditions chosen for a smaller scale Dashpot Drying Apparatus tested at Sandia National Laboratories in FY22. For a given uniform power and pressure/vacuum level, the ADCS was operated at constant power and pressure and allowed to reach steady state conditions. The thermal data obtained from these tests were analyzed, and the results can inform computational models built to simulate commercial drying processes by providing baseline thermal data prior to the introduction of water. Following the preliminary dry tests, a test plan for the ADCS will be developed to implement a drying procedure that begins with the introduction of water to the system and is based on measurements from the drying process used for the High Burnup Demonstration Project. While applying power to the simulated fuel rods, this procedure is expected to consist of filling the ADCS vessel with water, draining the water with applied pressure and multiple helium blowdowns, evacuating additional water with a vacuum drying sequence at successively lower pressures, and backfilling the vessel with helium. Additional investigations are expected to feature failed fuel rod simulators with engineered cladding defects and guide tubes with obstructed dashpots to challenge the drying system with multiple water retention sites. The data from these investigations is expected to inform the efficacy of commercial drying operations through the quantification of residual water in a prototypic-length dry storage canister.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Deployment of an Advanced Electrocardiographic Analysis (A-ECG) to Detect Cardiovascular Risk in Career Firefighters

INTRODUCTION Sudden cardiac death is the leading cause of line of duty death among firefighters, accounting for approximately 45% of fatalities annually. Firefighters perform strenuous muscular work while wearing heavy, encapsulating personal protective equipment in high ambient temperatures, under chaotic and emotionally stressful conditions. These factors can precipitate sudden cardiac events like myocardial infarction, serious dysrhythmias, or cerebrovascular accidents in firefighters with underlying cardiovascular disease. Screening for cardiovascular risk factors is recommended but not always followed in this population. PHASER is a project charged with identifying and prioritizing risk factors in emergency responders. We have deployed an advanced ECG (A-ECG) system developed at NASA for improved sensitivity and specificity in the detection of cardiac risk. METHODS Forty-four professional firefighters were recruited to perform comprehensive baseline assessments including tests of aerobic performance and laboratory tests for fasting lipid profiles and glucose. Heart rate and conventional 12-lead ECG were obtained at rest and during incremental treadmill exercise testing (XT). In addition, a 5-min resting 12-lead A-ECG was obtained in a subset of firefighters (n=18) and transmitted over a secure networked system to a physician collaborator at NASA for advanced-ECG analysis. This A-ECG system has been proven, using myocardial perfusion and other imaging, to accurately identify a number of cardiac pathologies including coronary artery disease (CAD), left ventricular hypertrophy, hypertrophic cardiomyopathy, non-ischemic cardiomyopathy, and ischemic cardiomyopathy. RESULTS Subjects mean (SD) age was 43 (8) years, weight 91 (13) kg, and BMI of 28 (3) kg/square meter. Maximum oxygen uptake (VO2max) was 39 (9) ml/kg/min. This compares with the 45th %ile in healthy reference values and a recommended standard of 42 ml/kg/min for firefighters. The metabolic threshold (VO2Theta) above which lactate accumulates was 23 (8) ml/kg/min. The chronotropic index, a measure of cardiovascular strain during XT was 35 (8) /L compared with reference values for men of 40 /L. Total cholesterol, LDL-C and HDL-C were 202 (34),126 (29), and 55 (15) mg/dl, respectively. Fifty-one percent of subjects had .3 cardiovascular risk factors, 2 subjects had resting hypertension (BP.140/90), and 23 had pre-hypertension (.120/80 but <140/90). Seven had exaggerated exercise induced hypertension but only one had ST depression on XT ECG, at least one positive A-ECG score for CAD, and documented CAD based on cardiology referral. While all other subjects, including those with fewer risk factors, higher aerobic fitness, and normal exercise ECGs, were classified as healthy by A-ECG, there was no trend for association between risk factors and any of 20 A-ECG parameters in the grouped data. CONCLUSIONS A-ECG screening correctly identified the individual with CAD although there was no trend for A-ECG parameters to distinguish those with elevated BP or multiple risk factors but normal XT ECG. We have demonstrated that a new technology, advanced-ECG, can be introduced for remote firefighter risk assessment. This simple, time and cost-effective approach to risk identification that can be acquired remotely and transmitted securely can detect individuals potentially at risk for line-of-duty death. Additional research is needed to further document its value.

Dolezal, B. A.↗

High Temperature Steam Electrolysis Process Performance and Cost Estimates

Technology readiness levels (TRLs) of electrolysis systems have dramatically increased in recent years as the interest in clean hydrogen production and decarbonization of transportation, industrial and other sectors increases across the globe. This is especially true of high temperature steam electrolysis (HTSE) / solid oxide electrolysis cell (SOEC) systems which show promise of much higher system efficiencies than other more developed electrolysis technologies. This possibility of higher efficiencies of HTSE / SOEC systems has been previously assumed to be theoretically possible but in recent years it has become less theoretical and more realistic as an increasing amount of suppliers complete lab and pilot tests showing very promising results. Research in the areas of manufacturing techniques, material selection, electrode and electrolyte compositions, and balance of plant size and integration continues at a fast pace as an increasing number of suppliers both internationally and domestically become involved. The advantages of HTSE become more pronounced when HTSE is coupled with nuclear power plants (NPPs). This is because thermal energy produced by the nuclear reactor can be used in a series of heat transfer loops and heat exchangers to vaporize HTSE feedwater, which drastically improves the economics of the process. Idaho National Laboratory (INL) has been very involved in the research and modeling of HTSE systems for a number of years, in collaboration with other national laboratories, academia, and industry stakeholders both on the hydrogen production as well as the hydrogen demand side. The modeling completed over the years on a large variety of projects has led to a wealth of knowledge at INL including in the area of the technoeconomic assessment (TEA) of HTSE systems. TEAs include process modeling of the HTSE systems to calculate system energy requirements and equipment sizing, followed by estimation of capital and operating costs to enable calculation of the levelized cost of hydrogen (LCOH). The TEA work performed has produced incremental improvements and tuning of the methods, assumptions, models, and results of the analyses as well as providing some opportunities for validating these results. The purpose of this document is to record the current baseline HTSE analyses led by INL to show the current status of assumptions and costs of these systems. Given the rapid development of this technology, the variety of suppliers entering the space, and the increasing attention government and industry are giving to such systems, this document may be updated on a periodic basis with updated analysis and assumptions. This document compiles various analyses results and approaches completed over a period of years into a single document to be used as a baseline going forward. It represents what the INL HTSE analysis group assumes to be the internal best estimate of the current operation, costs, and landscape of the HTSE industry state of the art capability for current SOEC technology in an Nth-of-a-Kind (NOAK) plant, which in this study is defined as existence of the manufacturing capacity to support previous deployment of N = 100 count of 25 MWe modular HTSE blocks (with modular equipment component cost reductions specified as following a 95% learning curve). That said, This is a public document and as such so no proprietary data was used or included in this report. There may be HTSE suppliers that have performance specifications, and cost estimates, and test data that differ from the analysis presented in this document. This document is meant to be a best conservative estimate of the technology and not an absolute reference.

08 HYDROGEN↗

Optimal integer resolution for attitude determination using global positioning system signals

In this paper, a new motion-based algorithm for GPS integer ambiguity resolution is derived. The first step of this algorithm converts the reference sightline vectors into body frame vectors. This is accomplished by an optimal vectorized transformation of the phase difference measurements. The result of this transformation leads to the conversion of the integer ambiguities to vectorized biases. This essentially converts the problem to the familiar magnetometer-bias determination problem, for which an optimal and efficient solution exists. Also, the formulation in this paper is re-derived to provide a sequential estimate, so that a suitable stopping condition can be found during the vehicle motion. The advantages of the new algorithm include: it does not require an a-priori estimate of the vehicle's attitude; it provides an inherent integrity check using a covariance-type expression; and it can sequentially estimate the ambiguities during the vehicle motion. The only disadvantage of the new algorithm is that it requires at least three non-coplanar baselines. The performance of the new algorithm is tested on a dynamic hardware simulator.

Crassidis, John L.↗

Aerosols and Particulates Workshop Sampling Procedures and Venues Working Group Summary

The Sampling Procedures and Venues Workgroup discussed the potential venues available and issues associated with obtaining measurements. Some of the issues included Incoming Air Quality, Sampling Locations, Probes and Sample Systems. The following is a summary of the discussion of the issues and venues. The influence of inlet air to the measurement of exhaust species, especially trace chemical species, must be considered. Analysis procedures for current engine exhaust emissions regulatory measurements require adjustments for air inlet humidity. As a matter of course in scientific investigations, it is recommended that "background" measurements for any species, particulate or chemical, be performed during inlet air flow before initiation of combustion, if possible, and during the engine test period as feasible and practical. For current regulatory measurements, this would be equivalent to setting the "zero" level for conventional gas analyzers. As a minimum, it is recommended that measurements of the humidity and particulates in the incoming air be taken at the start and end of each test run. Additional measurement points taken during the run are desirable if they can be practically obtained. It was felt that the presence of trace gases in the incoming air is not a significant problem. However, investigators should consider the ambient levels and influences of local air pollution for species of interest. Desired measurement locations depend upon the investigation requirements. A complete investigation of phenomenology of particulate formation and growth requires measurements at a number of locations both within the engine and in the exhaust field downstream of the nozzle exit plane. Desirable locations for both extractive and in situ measurements include: (1) Combustion Zone (Multiple axial locations); (2) Combustor Exit (Multiple radial locations for annular combustors); (3) Turbine Stage (Inlet and exit of the stage); (4) Exit Nozzle (Multiple axial locations downstream of the nozzle). Actual locations with potential for extractive or non-intrusive measurements depend upon the test article and test configuration. Committee members expressed the importance of making investigators aware of various ports that could allow access to various stages of the existing engines. Port locations are engine si)ecific and might allow extractive sampling or innovative hybrid optical-probe access. The turbine stage region was one the most desirable locations for obtaining samples and might be accessed through boroscope ports available in some engine designs. Discussions of probes and sampling systems quickly identified issues dependent on particular measurement quantities. With general consensus, the group recommends SAE procedures for measurements and data analyses of currently regulated exhaust species (CO2, CO, THC, NO(x),) using conventional gas sampling techniques. Special procedures following sound scientific practices must be developed as required for species and/or measurement conditions not covered by SAE standards. Several issues arose concerning short lived radicals and highly reactive species. For conventional sampling, there are concerns of perturbing the sample during extraction, line losses, line-wall reactions, and chemical reactions during the sample transport to the analyzers. Sample lines coated with quartz.or other materials should be investigated for minimization of such effects. The group advocates the development of innovative probe techniques and non-intrusive optical techniques for measurement of short lived radicals and highly reactive species that cannot be sampled accurately otherwise. Two innovative probe concepts were discussed. One concept uses specially designed probes to transfer optical beams to and from a region of flow inaccessible by traditional ports or windows. The probe can perturb the flow field but must have a negligible impact on the region to be optically sampled. Such probes are referred to as hybrid probes and are under development at AEDC for measurement in the high pressure, high temperature of a combustor under development for power generation. The other concept consists of coupling an instrument directly to the probe. The probe would isolate a representative sample stream, freeze chemical reactions and direct the sample into the analyzer portion of the probe. Thus, the measurement would be performed in situ without sample line losses due either to reactions or binding at the wall surfaces. This concept was used to develop a fast, in situ, time-of-flight mass spectrometer measurement system for temporal quantification of NO in the IMPULSE facility at AEDC. Additional work is required in this area to determine the best probe and sampling technique for each species measurement requirement identified by the Trace Chemistry Working Group. A partial list of Venues was used as a baseline for discussion. Additional venues were added to the list and the list was broken out into the following categories: (1)Engines (a) Sea Level Test Stands (b) Altitude Chambers; (2) Annular Combustor Test Stands, (3) Sector Flametube Test Stands, (4) Fundamentals Rigs/Experiments.

Pachlhofer, Peter↗

High Temperature Steam Electrolysis Process Performance and Cost Estimates - DOE Hydrogen Program AMR Presentation

Technology readiness levels (TRLs) of electrolysis systems have dramatically increased in recent years as the interest in clean hydrogen production and decarbonization of transportation, industrial and other sectors increases across the globe. This is especially true of high temperature steam electrolysis (HTSE) / solid oxide electrolysis cell (SOEC) systems which show promise of much higher system efficiencies than other more developed electrolysis technologies. This possibility of higher efficiencies of HTSE / SOEC systems has been previously assumed to be theoretically possible but in recent years it has become less theoretical and more realistic as an increasing amount of suppliers complete lab and pilot tests showing very promising results. Research in the areas of manufacturing techniques, material selection, electrode and electrolyte compositions, and balance of plant size and integration continues at a fast pace as an increasing number of suppliers both internationally and domestically become involved. The advantages of HTSE become more pronounced when HTSE is coupled with nuclear power plants (NPPs). This is because thermal energy produced by the nuclear reactor can be used in a series of heat transfer loops and heat exchangers to vaporize HTSE feedwater, which drastically improves the economics of the process. Idaho National Laboratory (INL) has been very involved in the research and modeling of HTSE systems for a number of years, in collaboration with other national laboratories, academia, and industry stakeholders both on the hydrogen production as well as the hydrogen demand side. The modeling completed over the years on a large variety of projects has led to a wealth of knowledge at INL including in the area of the technoeconomic assessment (TEA) of HTSE systems. TEAs include process modeling of the HTSE systems to calculate system energy requirements and equipment sizing, followed by estimation of capital and operating costs to enable calculation of the levelized cost of hydrogen (LCOH). The TEA work performed has produced incremental improvements and tuning of the methods, assumptions, models, and results of the analyses as well as providing some opportunities for validating these results. The purpose of this document is to record the current baseline HTSE analyses led by INL to show the current status of assumptions and costs of these systems. Given the rapid development of this technology, the variety of suppliers entering the space, and the increasing attention government and industry are giving to such systems, this document may be updated on a periodic basis with updated analysis and assumptions. This document compiles various analyses results and approaches completed over a period of years into a single document to be used as a baseline going forward. It represents what the INL HTSE analysis group assumes to be the internal best estimate of the current operation, costs, and landscape of the HTSE industry state of the art capability for current SOEC technology in an Nth-of-a-Kind (NOAK) plant, which in this study is defined as existence of the manufacturing capacity to support previous deployment of N = 100 count of 25 MWe modular HTSE blocks (with modular equipment component cost reductions specified as following a 95% learning curve). That said, this is a public document and as such so no proprietary data was used or included in this report. There may be HTSE suppliers that have performance specifications, and cost estimates, and test data that differ from the analysis presented in this document. This document is meant to be a best conservative estimate of the technology and not an absolute reference.

08 HYDROGEN↗