Search NASA⌕ Search

SEARCH · Search NASA

Results for “beam profile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

An automated approach to the alignment of compound refractive lenses

Compound refractive lenses (CRLs) are established X-ray focusing optics, and are used to focus the beam or image the sample in many beamlines at X-ray facilities. While CRLs are quite established, the stack of single lens elements affords a very small numerical aperture because of the thick lens profile, making them far more difficult to align than classical optical lenses that obey the thin-lens approximation. This means that the alignment must be very precise and is highly sensitive to changes to the incident beam, often requiring regular readjustments. Some groups circumvent the full realignment procedure by using engineering controls ( e.g. mounting optics) that sacrifice some of the beam's focusing precision, i.e. spot size, or resolution. While these choices minimize setup time, there are clear disadvantages. This work presents a new automated approach to align CRLs using a simple alignment apparatus that is easy to adapt and install at different types of X-ray experiments or facilities. This approach builds on recent CRL modeling efforts, using an approach based on the Stochastic Nelder–Mead (SNM) simplex method. This method is outlined and its efficacy is demonstrated with numerical simulation that is tested in real experiments conducted at the Advanced Photon Source to confirm its performance with a synchrotron beam. This work provides an opportunity to automate key instrumentation at X-ray facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Behavior and properties of helium cavities in ductile-phase-toughened tungsten irradiated with He + ions at an elevated temperature

Ductile-phase toughened tungsten (DPT W) composites have demonstrated a great potential for plasma-facing components in fusion power systems. These materials can retain the outstanding thermomechanical properties of W while significantly enhancing the fracture toughness. The DPT W composite in this study consists of W particles (88 wt.%) embedded in a ductile NiFeW (12 wt.%) solution matrix. Irradiation of the composite was performed with 90 keV He + ions to 1.0 × 10 17 He + /cm 2 at 973 K. The He cavities formed in both W and NiFeW phases are examined using convergent-beam scanning transmission electron microscopy (CB-STEM) at an atomic-level resolution. Full-range depth profiles of the He cavity diameters and number densities are analyzed. The results show that the average cavity diameter in NiFeW is ~2.7 times that in W, while the number density is an order of magnitude lower. A quantitative analysis of the He density and pressure in the cavities is also achieved using STEM electron energy loss spectroscopy (STEM-EELS) mapping. The He atoms in the cavities in NiFeW are found to be under-pressurized, while those in similar-sized cavities in W are not detectable. Further, the He energy-loss shift exhibits a linear relationship with the He density in cavities in NiFeW, with the slope comparable to that for martensitic steel.

36 MATERIALS SCIENCE↗

The NanoSIMS-HR: The Next Generation of High Spatial Resolution Dynamic SIMS

The high lateral resolution and sensitivity of the NanoSIMS 50 and 50L series of dynamic SIMS instruments have enabled numerous scientific advances over the past 25 years. Here, in this study, we report on the NanoSIMS-HR, the first major upgrade to the series, and analytical tests in a suite of sample types, including an aluminum sample containing silicon crystals, microalgae, and plant roots colonized with a symbiotic fungus. Significant improvements have been made in the Cs + ion source, high voltage (HV) control, stage reproducibility, and other aspects of the instrument that affect performance. The modified design of the NanoSIMS-HR thermal-ionization Cs + source enables a 5 pA primary ion beam to be focused into a 100 nm spot, a ~2.5-fold increase compared to Cs + sources on previous instruments (~2 pA at 100 nm). The brightness of the new Cs + source enables an ultimate lateral resolution as high as 30 nm and improved detection limits for a given analysis area. Sample stage movement accuracy is higher than 500 nm, enabling many-fold higher throughput automated analyses. With the new HV control, the primary ion beam impact energy can be reduced from 16 to 2 keV, which enables higher depth resolution during depth profiling (a 2-fold improvement), albeit with a 5-fold decrease in lateral resolution. In the NanoSIMS-HR, the secondary ion column and detection system are identical to those used in the previous series, and the isotopic analysis performance is as precise as in previous NanoSIMS instruments.

54 ENVIRONMENTAL SCIENCES↗

Silicon implantation and annealing in β -Ga 2 O 3 : Role of ambient, temperature, and time

Optimizing thermal anneals of Si-implanted β-Ga 2 O 3 is critical for low resistance contacts and selective area doping. Here we report the impact of annealing ambient, temperature, and time on the activation of room temperature ion-implanted Si in β-Ga 2 O 3 at concentrations from 5 × 10 18 to 1 × 10 20 cm −3 , demonstrating full activation (>80% activation, mobilities >70 cm 2 /V s) with contact resistances below 0.29 Ω mm. Homoepitaxial β-Ga 2 O 3 films, grown by plasma-assisted molecular beam epitaxy on Fe-doped (010) substrates, were implanted at multiple energies to yield 100 nm box profiles of 5 × 10 18 , 5 × 10 19, and 1 × 10 20 cm −3 . Anneals were performed in an ultra-high vacuum-compatible quartz furnace at 1 bar with well-controlled gas compositions. To maintain β-Ga 2 O 3 stability, p O2 must be greater than 10 −9 bar. Anneals up to p O2 = 1 bar achieve full activation at 5 × 10 18 cm −3, while 5 × 10 19 cm −3 must be annealed with p O2 ≤ 10 −4 bar, and 1 × 10 20 cm −3 requires p O2 < 10 −6 bar. Water vapor prevents activation and must be maintained below 10 −8 bar. Activation is achieved for anneal temperatures as low as 850 °C with mobility increasing with anneal temperatures up to 1050 °C, though Si diffusion has been reported above 950 °C. At 950 °C, activation is maximized between 5 and 20 min with longer times resulting in decreased carrier activation (over-annealing). This over-annealing is significant for concentrations above 5 × 10 19 cm −3 and occurs rapidly at 1 × 10 20 cm −3 . Rutherford backscattering spectrometry (channeling) suggests that damage recovery is seeded from remnant aligned β-Ga 2 O 3 that remains after implantation; this conclusion is also supported by scanning transmission electron microscopy showing retention of the β-phase with inclusions that resemble the γ-phase.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantifying the thermal effect and methyl radical production in nanosecond repetitively pulsed glow discharges applied to a methane-air flame

In this work, we investigated non-equilibrium plasma produced by nanosecond repetitively pulsed glow discharges applied across a lean premixed methane-air flame. The flame is stationary, axisymmetric, and laminar. The discharges are applied on the symmetry axis crossing the reactant gases, flame front, and product gases, allowing phase-locked averaged measurements and comparisons with axisymmetric numerical simulations. The thermal effect and methyl radical production are quantified in the discharge in the reactant gas region. One-dimensional, two-beam, hybrid, femtosecond-picosecond, coherent anti-Stokes Raman scattering is used to acquire spatial and temporal profiles of temperature and oxygen-to-nitrogen concentration ratio. Photo-fragmentation laser-induced fluorescence is used to acquire quantitative two-dimensional profiles of methyl radicals in the discharge providing the first quantitative imaging of methyl produced ahead of a flame by plasma-induced methane dissociation. The spatial profiles of temperature and oxygen-to-nitrogen concentration ratio are in steady state, indicating that individual discharges have an insignificant heating effect. Upper and lower bounds of the produced mole fraction of methyl radicals in the plasma are obtained due to uncertainties in the collisional quenching rates of excited state methylidyne radicals in the plasma. The discharges produce a maximum of 600–1100 ppm of methyl radicals upstream of the flame front within 25 ns. This amount is similar to the predicted methyl mole fraction for the flame without plasma and thus represents a significant chemical perturbation to the reactants upstream of the flame front. The produced methyl follows an exponential decay in the first microsecond after the discharge with a decay constant of 8 µs close to the flame, and 0.8 µs further from the flame. The decay then deviates from the exponential curve and the methyl persists for tens of microseconds. The results suggest that for the tested configuration, the thermal effect of individual discharges through fast gas heating is negligible, while active chemical species are produced in large quantities in the reactant gases, upstream of the flame front.

hybrid fs-ps CARS↗

Vortex rings in event-by-event relativistic heavy-ion collisions

We present event-by-event simulations for central asymmetric light+heavy and Au +Au collisions to investigate the formation and evolution of vortex-ring structures in the longitudinal flow velocity profile. The production-plane polarization of Λ hyperons, defined with respect to the Λ momentum and the beam, can track the “vortex-ring” feature in the event, a characteristic vortical structure generated by longitudinal flow gradients. We make comprehensive model predictions for the rapidity-dependent vortex-ring observables for different collision system sizes at √s NN = 200 and 72 GeV. Furthermore, our predictions at the latter energy can be explored in the future LHCb fixed-target experiment at the Large Hadron Collider.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Exact design of complex amplitude holograms for producing arbitrary scalar fields

Typical methods to holographically encode arbitrary wavefronts assume the hologram medium only applies either phase shifts or amplitude attenuation to the wavefront. In many cases, phase cannot be introduced to the wavefront without also affecting the amplitude. Here we show how to encode an arbitrary wavefront into an off-axis transmission hologram that returns the exact desired arbitrary wavefunction in a diffracted beam for phase-only, amplitude-only, or mixed phase and amplitude holograms with any periodic groove profile. We apply this to design thin holograms for electrons in a TEM, but our results are generally applicable to light and X-ray optics. We employ a phase reconstruction from a series of focal plane images to qualitatively show the accuracy of this method to impart the expected amplitude and phase to a specific diffraction order.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improved quantitation of SIMS depth profile measurements of niobium via sample holder design improvements and characterization of grain orientation effects

The importance of SIMS analyses for “N-doped” impurity alloyed niobium and other surface-alloyed materials continues to increase. A major hurdle is the uncertainty of instrument calibration due to changes in sample height either from sample surface topography or from the sample holder itself. The CAMECA sample holder design allows for many types of samples to be analyzed. However, a drawback is that the holder faceplate can bend, contributing an uncertainty in the relative sensitivity factor (RSF) used to quantify the SIMS results. Here, we describe an improved sample holder having a reinforced faceplate, which prevents deflection and reduces uncertainty. Simulations show that the new design significantly reduces deflection from 10 μm to 5 nm. Sample measurements show a reduction of RSF uncertainty from this source from 4.1% to 0.95%. Grain orientation has long been suspected to affect RSF measurement as well. A bicrystal implant standard, consisting of randomly oriented and [001] grains, was successively rotated 15° between analyses. It was observed that 20% of the analyses performed on the randomly oriented grain exhibited anomalously high RSF values as well as slow sputter rates. These features were associated with the changing grain normal orientation with respect to the primary Cs + beam. The grain orientation associated with the rise in RSF was simulated and determined to be the [101] crystallographic plane, thus indicating that ion channeling was responsible for the significantly increased RSF. Focused ion beam analysis confirmed slower sputter rates for the cardinal crystallographic orientations, indicating that ion channeling occurred for each.

43 PARTICLE ACCELERATORS↗

AWAKEN-ABLWF22 CLAMPS1 Doppler Lidar Vertical Velocity Profiles

These files contain 24 hour periods of data collected from the CLAMPS1 Halo Streamline Doppler lidar. While not conducting other scans, the lidar directs the beam to zenith, allowing for the measurement of vertical velocity. These data were collected during the American Wake Experiment (AWAKEN) project. The CLAMPS1 facility was deployed at the Rolling Meadows Golf Course east of Enid, OK.

54 ENVIRONMENTAL SCIENCES↗

An ultrafast laser pulse picker technique for high-average-current high-brightness photoinjectors

Beam diagnostics in high brightness photoinjectors requires that optical pulses from a high-power drive laser be picked up with an ultrahigh pulse contrast ratio and without temporal profile distortion. In high-average-current high-brightness photoinjectors, high-power drive lasers are routinely operated at GHz-level pulse repetition rate and it is challenging to achieve pulse picking without any pulse distortion. Here, we report on a new ultrafast pulse picker technique for beam diagnostics in high-average-current high-brightness photoinjectors. By efficiently combining an ultrafast low-power electro-optic modulator, high-power fiber laser amplifiers, a high-power Pockels Cell, and a frequency doubling module, we have successfully demonstrated optical bunch (30 pulses per bunch) pickup from a 704 MHz high-power drive laser and achieved a 10 6 :1 pulse contrast ratio and nearly zero pulse distortion. The performance of this pulse picking technique has been verified through beam characterization and electron cooling in the low energy RHIC electron cooling accelerator at Brookhaven National Laboratory.

43 PARTICLE ACCELERATORS↗

A multi-sheath model for highly nonlinear plasma wakefields

An improved description for nonlinear plasma wakefields with phase velocities near the speed of light is presented and compared against fully kinetic particle-in-cell simulations. These wakefields are excited by intense particle beams or lasers pushing plasma electrons radially outward, creating an ion bubble surrounded by a sheath of electrons characterized by the source term S≡−1enp(ρ−Jz/c), where ρ and Jz are the charge and axial current densities, respectively. Previously, the sheath source term was described phenomenologically with a positive-definite function, resulting in a positive definite wake potential. In reality, the wake potential is negative at the rear of the ion column which is important for self-injection and accurate beam loading models. To account for this, we introduce a multi-sheath model in which the source term, S, of the plasma wake can be negative in regions outside the ion bubble. Using this model, we obtain a new expression for the wake potential and a modified differential equation for the bubble radius. Numerical results obtained from these equations are validated against particle-in-cell simulations for unloaded and loaded wakes. The new model provides accurate predictions of the shape and duration of trailing bunch current profiles that flatten plasma wakefields. It is also used to design a trailing bunch for a desired longitudinally varying loaded wakefield. We present beam loading results for laser wakefields and discuss how the model can be improved for laser drivers in future work. Finally, we discuss differences between the predictions of the multi- and single-sheath models for beam loading.

Dalichaouch, T. N. (ORCID:0000000247350150)↗

Investigating the FLASH Effect in a Rat Brain Organotypic Model With a Novel High-Energy Electron Beam

Ultrahigh dose rate (FLASH) radiation therapy is reported to reduce normal tissue toxicity while maintaining tumor control; however, mechanism(s) remain obscure. To study FLASH mechanisms in brain tissue, we developed a novel experimental platform featuring a specialized high-energy electron linear accelerator, High Intensity Gamma Ray Source (HIGS), paired with an organotypic ex vivo brain metastasis model. We varied interpulse spacing to modulate the mean dose rate (MDR) of our unique 35 MeV electron beam, while maintaining extremely high instantaneous dose rate (IDR). We characterized dosimetry and targeting accuracy of the FLASH beam with film dosimetry. We combined this FLASH beam with an organotypic rat brain slice/breast carcinoma coculture model of brain metastasis to assess effects on normal and neoplastic tissues. Live-cell and bioluminescence imaging demonstrated cancer cell growth effects, whereas normal tissue responses and immune activation were assessed using live-cell imaging, cytokine profiles, and confocal microscopy. Here, we performed comparison experiments with 20 MeV electrons from a Varian clinical linear accelerator (VCLA) using conventional dose rates. The highest IDR of the FLASH beam to date was 20.7 ± 0.6 MGy/s, with maximum MDR of 20.7 MGy/s delivered in 1 pulse of 1 µs duration. Beam targeting was accurate to <1 mm and reproducible. HIGS-FLASH and VCLA dose rates equivalently decreased cancer cell growth. HIGS-FLASH irradiation significantly increased tumor necrosis factor α and fractalkine levels and confocal microscopy revealed distinct changes in microglial morphology slices suggesting microglia activation. Our novel experimental platform produces extremely high dose rates and rapid normal/neoplastic tissue readouts for mechanistic research into the effects of FLASH radiation in the brain. HIGS-FLASH irradiation induces comparable cancer cell growth inhibition but differential effects on cytokines and microglial morphology, suggesting that acute innate immune responses may be involved in FLASH normal tissue effects in the brain.

Kay, Tyler V. [Duke University, Durham, NC (United↗

Niowave Neutron Source Converter: Lead-Bismuth-Eutectic (LBE) Windowless Target Design and Evaluation

Los Alamos National Laboratory (LANL) is working with Niowave on the design and evaluation of their lead-bismuth-eutectic (LBE) windowless target (i.e., neutron source converter). Niowave plans to use 200 kW electron beam at 40 MeV beam energy to produce neutrons by photonuclear reaction with LBE. Then, the neutrons undergo fission at the surrounding uranium target assembly (UTA) to produce Molybdenum 99 (Mo-99) as a fission product, which eventually decays to Technetium-99 (Tc-99m). Tc-99m is one of important radioisotopes that is used for medical diagnostics. LANL conducted 3D multiphysics analysis for the Niowave neutron converter design and provided design assessment in thermohydraulic aspects. LANL conducted radiation transport calculations using Monte-Carlo N-Particle (MCNP) code with unstructured meshing scheme. The 3D volumetric heating profiles in the LBE and Stainless-Steel (SS) housing were imported into multiphase computational fluid dynamics (CFD) to obtain 3D temperature profiles of LBE and SS through conjugate heat transfer (CHT) analysis. The key findings are: LBE film thickness at the center of the beam is approximately 1.6 cm with a maximum LBE velocity of approximately 1.8 m/s, which is below a 2 m/s limit to avoid erosion issues on supporting structures; Heat deposition in the LBE peaks at ~1 cm depth from the LBE free-surface because of the forward interactions of electron, photon, and neutron with LBE; LBE maximum temperature is ~360 °C, which is below LBE evaporation initiative temperature, ~450 °C; LBE-SS interface temperature is ~350 °C, which is below the safety thermal limit to prevent severe corrosion on SS. The results indicate that Niowave’s neutron converter design satisfies both hydraulic and thermal criteria for safe operation. By virtue of such computational analysis, Niowave can move toward establishing an experimental setup to experimentally test their LBE neutron converter. The following sections describe the detailed work done by LANL.

43 PARTICLE ACCELERATORS↗

Characterization of the Fusion Zone in Laser Beam Welds on SS304L

Designing a welded joint requires consideration of the welding process, component/assembly structure and weld geometry, material composition, properties, and desired joint performance. The designer must also specify a set of acceptance criteria used to evaluate the welds. This study was conducted to support the design team responsible for specifying the spot weld profile by investigating the relationship between weld process parameters and the weld geometry and properties to further inform design optimization. The subjects of this study are two thin stainless steel 304L (SS304L) components joined by Laser Beam Welding (LBW). The components are the Housing, which contains flexible circuitry, and the Cover that protects the circuitry during handling, installation, and under service loads. Figure 1 illustrates coupon versions of the Cover and Housing used to simulate the interface between these components for weld testing. These coupon representations of assembly components were designed to match the material and relevant geometry related to the welded joint while other features not relevant to the welded joint are excluded.The objective of this study was to characterize the sensitivity of the weld geometry and mechanical properties to the input weld parameters to inform further Finite Element Analysis (FEA) efforts in balancing joint strength against assembly deformation caused by the welding process. Characterization was accomplished by varying laser welding parameters around the current design values and measuring weld geometry on the cross-sections. Nanoindentation with a spherical and flat-ended tip was used on polished section cuts of the weld to obtain direct estimates of the stress-strain response of the Fusion Zone (FZ) for comparison to the Base Metal (BM).

42 ENGINEERING↗

A Foreshock Model for Interstellar Shocks of Solar Origin: Voyager 1 and 2 Observations

The Voyager 1 (V1) and Voyager 2 (V2) spacecraft were launched in 1977 on a mission to explore the outer planets and reach the heliopause, the boundary between the hot solar plasma and the relatively cool interstellar plasma. V1 reached the heliopause on 2012 August 25, at 121.6 au, and V2 reached the heliopause on 2018 November 5, at 119.0 au. One of their remarkable discoveries was the detection of shocks propagating into the interstellar plasma from energetic solar events. These shocks are typically preceded by electron plasma oscillations excited by electron beams streaming along interstellar magnetic field lines ahead of the shocks. The frequencies of the plasma oscillations have now provided radial electron density profiles in the outer heliosphere and in the interstellar medium to radial distances of more than 145 au. The oscillations are typically preceded by bursts of high-energy ∼5–100 MeV electrons. These electron bursts are interpreted as being due to the reflection (and acceleration) of cosmic-ray electrons by the shock at the time the shock first contacts the magnetic field line that passes through the spacecraft. Relative timing between the cosmic rays reflected by the shock and the onset of the plasma oscillations allow us, for the first time, to estimate the energy, ∼20–100 eV, of the electron beams responsible for the plasma oscillations. These observations are combined into a self-consistent model called the foreshock model that describes the interaction of shocks of solar origin with the interstellar plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

AWAKEN CLAMPS2 Doppler Lidar Vertical Velocity Profiles

These files contain 24 hour periods of data collected from the CLAMPS2 Halo Streamline XR+ Doppler lidar. While not conducting other scans, the lidar directs the beam to zenith, allowing for the measurement of vertical velocity. These data were collected during the AWAKEN project.

54 ENVIRONMENTAL SCIENCES↗

Laser-driven flash x-ray radiography of a shocked metallic foil

Characterizing hydrodynamic instability evolution in millimeter-scale, high-Z foils is crucial for understanding complex phenomena in high-energy-density physics. Here, we demonstrate a proof-of-concept, laser-driven flash x-ray radiography platform tailored for two-dimensional linear density mapping in shocked high-Z foils. Using chromium (Cr) foils with internal shockwaves (∼100 μm width), our platform achieves a spatial resolution of 59.8 ± 1.4 μm by employing a broadband x-ray source extending into the hundreds of keV range. The setup combines a compound parabolic concentrator cone with a tantalum wire target, a magnetic field to deflect residual transmitted electrons, and a copper casing to shield the sides and rear of the image plate pack. By varying the delay of the short-pulse beam driving the flash x-ray source, we resolve shockwave dynamics, specifically the velocity, position, width, and density profile, within the Cr foil. Reported experimental results are consistent with the corresponding hydrodynamics and radiation transport simulations, which accurately reproduce the measured electron and x-ray source terms. These developments enable the conversion of shockwave radiographs into two-dimensional density maps, enhancing interpretability for hydrodynamic instability evolution applications and validating the simulation approach.

36 MATERIALS SCIENCE↗

Characterisation of a laser plasma betatron source for high resolution x-ray imaging

Abstract We report on the characterisation of an x-ray source, generated by a laser-driven plasma wakefield accelerator. The spectrum of the optimised source was consistent with an on-axis synchrotron spectrum with a critical energy of 13.8 − 1.9 + 2.2 keV and the number of photons per pulse generated above 1 keV was calculated to be 6 − 0.9 + 1.2 × 10 9 . The x-ray beam was used to image a resolution grid placed 37 cm from the source, which gave a measured spatial resolution of 4 µ m × 5 µ m. The inferred emission region had a radius and length of 0.5 ± 0.2 µ m and 3.2 ± 0.9 mm respectively. It was also observed that laser damage to the exit aperture of the gas cell led to a reduction in the accelerated electron beam charge and a corresponding reduction in x-ray flux due to the change in the plasma density profile.

plasma acceleration↗