Search NASA⌕ Search

SEARCH · Search NASA

Results for “camera response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Millimeter-Wave Localizers for Aircraft-to-Aircraft Approach Navigation

Aerial refueling technology for both manned and unmanned aircraft is critical for operations where extended aircraft flight time is required. Existing refueling assets are typically manned aircraft, which couple to a second aircraft through the use of a refueling boom. Alignment and mating of the two aircraft continues to rely on human control with use of high-resolution cameras. With the recent advances in unmanned aircraft, it would be highly advantageous to remove/reduce human control from the refueling process, simplifying the amount of remote mission management and enabling new operational scenarios. Existing aerial refueling uses a camera, making it non-autonomous and prone to human error. Existing commercial localizer technology has proven robust and reliable, but not suited for aircraft-to-aircraft approaches like in aerial refueling scenarios since the resolution is too coarse (approximately one meter). A localizer approach system for aircraft-to-aircraft docking can be constructed using the same modulation with a millimeterwave carrier to provide high resolution. One technology used to remotely align commercial aircraft on approach to a runway are ILS (instrument landing systems). ILS have been in service within the U.S. for almost 50 years. In a commercial ILS, two partially overlapping beams of UHF (109 to 126 MHz) are broadcast from an antenna array so that their overlapping region defines the centerline of the runway. This is called a localizer system and is responsible for horizontal alignment of the approach. One beam is modulated with a 150-Hz tone, while the other with a 90-Hz tone. Through comparison of the modulation depths of both tones, an autopilot system aligns the approaching aircraft with the runway centerline. A similar system called a glide-slope (GS) exists in the 320-to-330MHz band for vertical alignment of the approach. While this technology has been proven reliable for millions of commercial flights annually, its UHF nature limits its ability to operate beyond the 1-to-2-meter precisions associated with commercial runway width. A prototype ILS-type system operates at millimeter-wave frequencies to provide automatic and robust approach control for aerial refueling. The system allows for the coupling process to remain completely autonomous, as a boom operator is no longer required. Operating beyond 100 GHz provides enough resolution and a narrow enough beamwidth that an approach corridor of centimeter scales can be maintained. Two modules were used to accomplish this task. The first module is a localizer/glide-slope module that can be fitted on a refueling aircraft. This module provides the navigation beams for aligning the approaching aircraft. The second module is navigational receiver fitted onto the approaching aircraft to be re fueled that can detect the approach beams. Since unmanned aircraft have a limited payload size and limited electrical power, the receiver portion was implemented in CMOS (complementary metal oxide semiconductor) technology based on a super-regenerative receiver (SRR) architecture. The SRR achieves mW-level power consumption and chip sizes less than l mm2. While super-regenerative techniques have small bandwidths that limit use in communication systems, their advantages of high sensitivity, low complexity, and low power make them ideal in this situation where modulating tones of less than 1 kHz are used.

Tang, Adrian J.↗

Post-fire time series of sensor and geochemistry sample data from surface water, groundwater, precipitation, soil, and vegetation across Oak Creek watershed, Washington

This dataset supports a broader study examining wildfire impacts on hydrologic connectivity across 5 sites within the Oak Creek watershed and the resulting biogeochemical impacts. Stream sites were selected using the Advanced Terrestrial Simulator (ATS) hydrologic model to identify locations with varying groundwater contributions and hydrologic responses across different burn severity scenarios. The Retreat Fire burned from July 23 to August 2 in 2024, affecting the five study sites at varying burn severities. Each site is equipped with YSI EXO2 sondes logging sub-hourly throughout the year, and grab samples are collected approximately every six weeks. YSI sondes are used to measure temporally resolved proxies for groundwater inputs (specific conductivity) and organic matter (fluorescent dissolved organic matter; fDOM) along with basic water quality and depth. Grab samples of surface water, groundwater, and precipitation are analyzed for water stable isotopes and conductivity to understand endmembers for hydrologic mixing Grab samples of surface water, groundwater, soil water, and litter/vegetation/soil leachates are analyzed for organic matter composition measured by Fourier-Transform Ion Cyclotron Resonance Mass Spectrometry (FTICR-MS) to understand organic matter dynamics. Game camera photos are provided in a separate data package available at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/3018598. Future versions of this dataset will include time series data from YSI EXO2 sondes (fDOM, dissolved oxygen, temperature, depth, specific conductance, turbidity, pH), BaroTROLL sensors (air temperature and barometric pressure), rain gauges (precipitation), and data from the soil and vegetation samples. Because this study is ongoing, this data package will be updated regularly to include newly collected data and the additional data types. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. In addition to a readme, this data package also includes a file-level metadata (FLMD) file that describes each file and a data dictionary (DD) that describes all column/row headers and variable definitions. This dataset is comprised of (1) a folder of field photos; (2) a folder of surface water sample data; (3) a folder of raw Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) data; (4) a data checks report; (5) file-level metadata; (6) data dictionary; (7) field metadata; (8) readme; (9) international generic sample number (IGSN) mapping file; and (10) field protocols. The sample data subfolder contains (1) dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) data and averages; (2) total dissolved nitrogen data and averages; (3) stable water isotopes and averages; (4) methods codes; (5) FTICR-MS methods; and (15) a subfolder of 9.4 Tesla (9.4T) FTICR-MS data. This folder contains the processed data and three subfolders, one containing the .xml files, one containing the water CoreMS output files, and the other containing instructions and scripts for processing the files in CoreMS (https://github.com/EMSL-Computing/CoreMS). All files are .csv, .pdf, .R, .xml, .d, .html, .Rmd, .py, .cal, .json, .jpg, .jpeg, .png, .mov, or .mp4.

Biogeochemistry↗

General Aviation Citizen Science Study to Help Tackle Remote Sensing of Harmful Algal Blooms (HABs)

We present a new, low-cost approach, based on volunteer pilots conducting high-resolution aerial imaging, to help document the onset, growth, and outbreak of harmful algal blooms (HABs) and related water quality issues in central and western Lake Erie. In this model study, volunteer private pilots acting as citizen scientists frequently flew over 200 mi of Lake Erie coastline, its islands, and freshwater estuaries, taking high-quality aerial photographs and videos. The photographs were taken in the nadir (vertical) position in red, green, and blue (RGB) and near-infrared (NIR) every 5 s with rugged, commercially available built-in Global Positioning System (GPS) cameras. The high-definition (HD) videos in 1080p format were taken continuously in an oblique forward direction. The unobstructed, georeferenced, high-resolution images, and HD videos can provide an early warning of ensuing HAB events to coastal communities and freshwater resource managers. The scientists and academic researchers can use the data to compliment a collection of in situ water measurements, matching satellite imagery, and help develop advanced airborne instrumentation, and validation of their algorithms. This data may help develop empirical models, which may lead to the next steps in predicting a HAB event as some watershed observed events changed the water quality such as particle size, sedimentation, color, mineralogy, and turbidity delivered to the Lake site. This paper shows the efficacy and scalability of citizen science (CS) aerial imaging as a complimentary tool for rapid emergency response in HABs monitoring, land and vegetation management, and scientific studies. This study can serve as a model for monitoring/management of freshwater and marine aquatic systems.

Ansari, Rafat R.↗

A simulation pipeline for fast neutron imaging and spectroscopy using quantified detector attributes

Radiation imaging capabilities, essential in the nuclear nonproliferation regime, facilitate source localization and, in certain cases, spectroscopy. Scatter-based neutron cameras, which can measure the neutron signatures from special nuclear material, hold particular interest. Systems incorporating organic scintillators can extract neutron energy spectra, potentially distinguishing fission neutron sources from others, such as alpha-neutron sources. The development and testing of a scatter-based neutron imager, however, can be challenging without having an accurate simulation model or first constructing a prototype. This work describes a simulation pipeline that takes output from MCNPX-PoliMi simulations and creates the expected back-projection neutron images and neutron energy spectra. This pipeline was developed to improve the modeling of fast neutron imagers and bridge the current gap in literature, which predominantly focuses on gamma-ray Compton imager models. This work also reports on the significance of various real-world system considerations and their effects on the simulated detector responses. The pipeline was verified and validated with experimental data collected using a 252 Cf spontaneous fission source using a fast neutron scattering imager developed at the University of Michigan.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

OP09O-OP404-9 Wide Field Camera 3 CCD Quantum Efficiency Hysteresis

The HST/Wide Field Camera (WFC) 3 UV/visible channel CCD detectors have exhibited an unanticipated quantum efficiency hysteresis (QEH) behavior. At the nominal operating temperature of -83C, the QEH feature contrast was typically 0.1-0.2% or less. The behavior was replicated using flight spare detectors. A visible light flat-field (540nm) with a several times full-well signal level can pin the detectors at both optical (600nm) and near-UV (230nm) wavelengths, suppressing the QEH behavior. We are characterizing the timescale for the detectors to become unpinned and developing a protocol for flashing the WFC3 CCDs with the instrument's internal calibration system in flight. The HST/Wide Field Camera 3 UV/visible channel CCD detectors have exhibited an unanticipated quantum efficiency hysteresis (QEH) behavior. The first observed manifestation of QEH was the presence in a small percentage of flat-field images of a bowtie-shaped contrast that spanned the width of each chip. At the nominal operating temperature of -83C, the contrast observed for this feature was typically 0.1-0.2% or less, though at warmer temperatures contrasts up to 5% (at -50C) have been observed. The bowtie morphology was replicated using flight spare detectors in tests at the GSFC Detector Characterization Laboratory by power cycling the detector while cold. Continued investigation revealed that a clearly-related global QE suppression at the approximately 5% level can be produced by cooling the detector in the dark; subsequent flat-field exposures at a constant illumination show asymptotically increasing response. This QE "pinning" can be achieved with a single high signal flat-field or a series of lower signal flats; a visible light (500-580nm) flat-field with a signal level of several hundred thousand electrons per pixel is sufficient for QE pinning at both optical (600nm) and near-UV (230nm) wavelengths. We are characterizing the timescale for the detectors to become unpinned and developing a protocol for flashing the WFC3 CCDs with the instrument's internal calibration system in flight. A preliminary estimate of the decay timescale for one detector is that a drop of 0.1-0.2% occurs over a ten day period, indicating that relatively infrequent cal lamp exposures can mitigate the behavior to extremely low levels.

Collins, Nick↗

Characterization of Lunar Swirls at Mare Ingenii: A Model for Space Weathering at Magnetic Anomalies

Analysis of spectra from the Clementine ultraviolet-visible and near-infrared cameras of small, immature craters and surface soils both on and adjacent to the lunar swirls at Marc Ingenii has yielded the following conclusions about space weathering at a magnetic anomaly. (l) Despite having spectral characteristics of immaturity, the lunar swirls arc not freshly exposed surfaces. (2) The swirl surfaces arc regions of retarded weathering, while immediately adjacent regions experience accelerated weathering, (3) Weathering in the off-swirl regions darkens and flattens the spectrum with little to no reddening, which suggests that the production of larger (greater than 40 nm) nanophase iron dominates in these locations as a result of charged particle sorting by the magnetic field. Preliminaty analysis of two other lunar swirl regions, Reiner Gamma and Mare Marginis, is consistent with our observations at Mare Ingenii. Our results indicate that sputtering/vapor deposition, implanted solar wind hydrogen, and agglutination share responsibility for creating the range in npFe(sup 0) particle sizes responsible for the spectral effects of space weathering.

Kramer, Georgianna Y.↗

A Mars Rover Mission Simulation on Kilauea Volcano

A field experiment to simulate a rover mission on Mars was performed using the Russian Marsokhod rover deployed on Kilauea Volcano HI in February, 1995. A Russian Marsokhod rover chassis was equipped with American avionics equipment, stereo cameras on a pan and tilt platform, a digital high resolution body-mounted camera, and a manipulator arm on which was mounted a camera with a close-up lens. The six wheeled rover is 2 meters long and has a mass of 120 kg. The imaging system was designed to simulate that used on the planned "Mars Together" mission. The rover was deployed on Kilauea Volcano HI and operated from NASA Ames by a team of planetary geologists and exobiologists. Two modes of mission operations were simulated for three days each: (1) long time delay, low data bandwidth (simulating a Mars mission), and (2) live video, wide-bandwidth data (allowing active control simulating a Lunar rover mission or a Mars rover mission controlled from on or near the Martian surface). Simulated descent images (aerial photographs) were used to plan traverses to address a detailed set of science questions. The actual route taken was determined by the science team and the traverse path was frequently changed in response to the data acquired and to unforeseen operational issues. Traverses were thereby optimized to efficiently answer scientific questions. During the Mars simulation, the rover traversed a distance of 800 m. Based on the time delay between Earth and Mars, we estimate that the same operation would have taken 30 days to perform on Mars. This paper will describe the mission simulation and make recommendations about incorporating rovers into the Mars surveyor program.

Stoker, Carol↗

AERCam Autonomy: Intelligent Software Architecture for Robotic Free Flying Nanosatellite Inspection Vehicles

The NASA Johnson Space Center has developed a nanosatellite-class Free Flyer intended for future external inspection and remote viewing of human spacecraft. The Miniature Autonomous Extravehicular Robotic Camera (Mini AERCam) technology demonstration unit has been integrated into the approximate form and function of a flight system. The spherical Mini AERCam Free Flyer is 7.5 inches in diameter and weighs approximately 10 pounds, yet it incorporates significant additional capabilities compared to the 35-pound, 14-inch diameter AERCam Sprint that flew as a Shuttle flight experiment in 1997. Mini AERCam hosts a full suite of miniaturized avionics, instrumentation, communications, navigation, power, propulsion, and imaging subsystems, including digital video cameras and a high resolution still image camera. The vehicle is designed for either remotely piloted operations or supervised autonomous operations, including automatic stationkeeping, point-to-point maneuvering, and waypoint tracking. The Mini AERCam Free Flyer is accompanied by a sophisticated control station for command and control, as well as a docking system for automated deployment, docking, and recharge at a parent spacecraft. Free Flyer functional testing has been conducted successfully on both an airbearing table and in a six-degree-of-freedom closed-loop orbital simulation with avionics hardware in the loop. Mini AERCam aims to provide beneficial on-orbit views that cannot be obtained from fixed cameras, cameras on robotic manipulators, or cameras carried by crewmembers during extravehicular activities (EVA s). On Shuttle or International Space Station (ISS), for example, Mini AERCam could support external robotic operations by supplying orthogonal views to the intravehicular activity (IVA) robotic operator, supply views of EVA operations to IVA and/or ground crews monitoring the EVA, and carry out independent visual inspections of areas of interest around the spacecraft. To enable these future benefits with minimal impact on IVA operators and ground controllers, the Mini AERCam system architecture incorporates intelligent systems attributes that support various autonomous capabilities. 1) A robust command sequencer enables task-level command scripting. Command scripting is employed for operations such as automatic inspection scans over a region of interest, and operator-hands-off automated docking. 2) A system manager built on the same expert-system software as the command sequencer provides detection and smart-response capability for potential system-level anomalies, like loss of communications between the Free Flyer and control station. 3) An AERCam dynamics manager provides nominal and off-nominal management of guidance, navigation, and control (GN&C) functions. It is employed for safe trajectory monitoring, contingency maneuvering, and related roles. This paper will describe these architectural components of Mini AERCam autonomy, as well as the interaction of these elements with a human operator during supervised autonomous control.

Fredrickson, Steven E.↗

IRAC test report. Gallium doped silicon band 2: Read noise and dark current

A direct readout infrared detector array, a candidate for the Space Infrared Telescope Facility (SIRTF) Infrared Array Camera (IRAC), has been tested. The array has a detector surface of gallium doped silicon, bump bonded to a 58x62 pixel MOSFET multiplexer on a separate chip. Although this chip and system do not meet all the SIRTF requirements, the critically important read noise is within a factor of 3 of the requirement. Significant accomplishments of this study include: (1) development of a low noise correlated double sampling readout system with a readout noise of 127 to 164 electrons (based on the detector integrator capacitance of 0.1 pF); (2) measurement of the readout noise of the detector itself, ranging from 123 to 214 electrons with bias only (best to worst pixel), and 256 to 424 electrons with full clocking in normal operation at 5.4 K where dark current is small. Thirty percent smaller read noises are obtained at a temperature of 15K; (3) measurement of the detector response versus integration time, showing significant nonlinear behavior for large signals, well below the saturation level; and (4) development of a custom computer interface and suitable software for collection, analysis and display of data.

Lamb, Gerald↗

Broadband Achromatic Telecentric Lens

A new type of lens design features broadband achromatic performance as well as telecentricity, using a minimum number of spherical elements. With appropriate modifications, the lens design form can be tailored to cover the range of response of the focal-plane array, from Si (400-1,000 nm) to InGaAs (400-1,700 or 2,100 nm) or InSb/HgCdTe reaching to 2,500 nm. For reference, lenses typically are achromatized over the visible wavelength range of 480-650 nm. In remote sensing applications, there is a need for broadband achromatic telescopes, normally satisfied with mirror-based systems. However, mirror systems are not always feasible due to size or geometry restrictions. They also require expensive aspheric surfaces. Non-obscured mirror systems can be difficult to align and have a limited (essentially one-dimensional) field of view. Centrally obscured types have a two-dimensional but very limited field in addition to the obscuration. Telecentricity is a highly desirable property for matching typical spectrometer types, as well as for reducing the variation of the angle of incidence and cross-talk on the detector for simple camera types. This rotationally symmetric telescope with no obscuration and using spherical surfaces and selected glass types fills a need in the range of short focal lengths. It can be used as a compact front unit for a matched spectrometer, as an ultra-broadband camera objective lens, or as the optics of an integrated camera/spectrometer in which the wavelength information is obtained by the use of strip or linear variable filters on the focal plane array. This kind of camera and spectrometer system can find applications in remote sensing, as well as in-situ applications for geological mapping and characterization of minerals, ecological studies, and target detection and identification through spectral signatures. Commercially, the lens can be used in quality-control applications via spectral analysis. The lens design is based on the rear landscape lens with the aperture stop in front of all elements. This allows sufficient room for telecentricity in addition to making the stop easily accessible. The crucial design features are the use of a doublet with an ultra-low dispersion glass (fluorite or S-FPL53), and the use of a strong negative element, which enables flat field and telecentricity in conjunction with the last (field lens) element. The field lens also can be designed to be in contact with the array, a feature that is desirable in some applications. The lens has a 20deg field of view, for a 50-mm focal length, and is corrected over the range of wavelengths of 450-2,300 nm. Transverse color, which is the most pernicious aberration for spectroscopic work, is controlled at the level of 1 m or below at 0.7 m field and 5 m at full field. The maximum chief ray angle is less than 1.7 , providing good telecentricity. An additional feature of this lens is that it is made exclusively with glasses that provide good transmission up to 2,300 nm and even some transmission to 2,500 nm; thus, the lens can be used in applications that cover the entire solar-reflected spectrum. Alternative realizations are possible that provide enhanced resolution and even less transverse color over a narrower wavelength range.

Mouroulis, Pantazis↗

Application of the pressure sensitive paint technique to steady and unsteady flow

Pressure sensitive paint is a newly-developed optical measurement technique with which one can get a continuous pressure distribution in much shorter time and lower cost than a conventional pressure tap measurement. However, most of the current pressure sensitive paint applications are restricted to steady pressure measurement at high speeds because of the small signal-to-noise ratio at low speed and a slow response to pressure changes. In the present study, three phases of work have been completed to extend the application of the pressure sensitive paint technique to low-speed testing and to investigate the applicability of the paint technique to unsteady flow. First the measurement system using a commercially available PtOEP/GP-197 pressure sensitive paint was established and applied to impinging jet measurements. An in-situ calibration using only five pressure tap data points was applied and the results showed good repeatability and good agreement with conventional pressure tap measurements on the whole painted area. The overall measurement accuracy in these experiments was found to be within 0.1 psi. The pressure sensitive paint technique was then applied to low-speed wind tunnel tests using a 60 deg delta wing model with leading edge blowing slots. The technical problems encountered in low-speed testing were resolved by using a high grade CCD camera and applying corrections to improve the measurement accuracy. Even at 35 m/s, the paint data not only agreed well with conventional pressure tap measurements but also clearly showed the suction region generated by the leading edge vortices. The vortex breakdown was also detected at alpha=30 deg. It was found that a pressure difference of 0.2 psi was required for a quantitative pressure measurement in this experiment and that temperature control or a parallel temperature measurement is necessary if thermal uniformity does not hold on the model. Finally, the pressure sensitive paint was applied to a periodically changing pressure field with a 12.8s time period. A simple first-order pole model was applied to deal with the phase lag of the paint. The unsteady pressure estimated from the time-changing pressure sensitive paint data agreed well with the pressure transducer data in regions of higher pressure and showed the possibility of extending the technique to unsteady pressure measurements. However, the model still needs further refinement based on the physics of the oxygen diffusion into the paint layer and the oxygen quenching on the paint luminescence.

Shimbo, Y.↗

The Astro-E2 Mission

The Astro-E2 observatory is a rebuild of the original Astro-E observatory that was lost during launch in February 2000. It is scheduled for launch into low earth orbit on a Japanese M-V rocket in early 2005. The Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency, is developing the observatory with major contributions from the US. The three instruments on the observatory are the high-resolution x-ray spectrometer (the XRS) featuring a 30-pixel x-ray microcalorimeter array, a set of four CCD cameras (the XIS) and a combination photo-diode/scintillator detector system (the HXD) that will extend the band pass up to nearly 700 keV. A significant feature of Astro-E2 is that all of the instruments are coaligned and operated simultaneously. With its high spectral resolution and collecting area for spectroscopy above 1 keV, Astro-E2 should enable major discovery space and pioneer new technology for use in space. Prime areas for investigation are supernova remnants, active galaxies and the measurement of black hole properties via relativistically-broadened Fe-K emission galaxies. A number of enhancements have been made for the Astro-E2/XRS, including a higher resolution microcalorimeter array, ii mechanical cooler for longer cryogen life, and an improved in-flight calibration system. The Astro-E2/XIS has also been improved to include two back-side-illuminated CCDs to enhance the low energy response. Improvements have also been made to the x-ray mirrors used for both the XRS and XIS to sharpen the point spread function and reduce the effects of stray light. In this talk we will present the essential features of Astro-E2, paying particular attention to the enhancements, and describe the major scientific strengths of the observatory.

Kelley, Richard L.↗

NASA Tech Briefs, September 2007

Topics covered include; Rapid Fabrication of Carbide Matrix/Carbon Fiber Composites; Coating Thermoelectric Devices To Suppress Sublimation; Ultrahigh-Temperature Ceramics; Improved C/SiC Ceramic Composites Made Using PIP; Coating Carbon Fibers With Platinum; Two-Band, Low-Loss Microwave Window; MCM Polarimetric Radiometers for Planar Arrays; Aperture-Coupled Thin-Membrane L-Band Antenna; WGM-Based Photonic Local Oscillators and Modulators; Focal-Plane Arrays of Quantum-Dot Infrared Photodetectors; Laser Range and Bearing Finder With No Moving Parts; Microrectenna: A Terahertz Antenna and Rectifier on a Chip; Miniature L-Band Radar Transceiver; Robotic Vision-Based Localization in an Urban Environment; Programs for Testing an SSME-Monitoring System; Cathodoluminescent Source of Intense White Light; Displaying and Analyzing Antenna Radiation Patterns; Payload Operations Support Team Tools; Space-Shuttle Emulator Software; Soft Real-Time PID Control on a VME Computer; Analyzing Radio-Frequency Coverage for the ISS; Nanorod-Based Fast-Response Pressure-Sensitive Paints; Capacitors Would Help Protect Against Hypervelocity Impacts; Diaphragm Pump With Resonant Piezoelectric Drive; Improved Quick-Release Pin Mechanism; Designing Rolling-Element Bearings; Reverse-Tangent Injection in a Centrifugal Compressor; Inertial Measurements for Aero-assisted Navigation (IMAN); Analysis of Complex Valve and Feed Systems; Improved Path Planning Onboard the Mars Exploration Rovers; Robust, Flexible Motion Control for the Mars Explorer Rovers; Solar Sail Spaceflight Simulation; Fluorine-Based DRIE of Fused Silica; Mechanical Alloying for Making Thermoelectric Compounds; Process for High-Rate Fabrication of Alumina Nanotemplates; Electroform/Plasma-Spray Laminates for X-Ray Optics; An Automated Flying-Insect Detection System; Calligraphic Poling of Ferroelectric Material; Blackbody Cavity for Calibrations at 200 to 273 K; KML Super Overlay to WMS Translator; High-Performance Tiled WMS and KML Web Server; Modeling of Radiative Transfer in Protostellar Disks; Composite Pulse Tube; Photometric Calibration of Consumer Video Cameras; Criterion for Identifying Vortices in High- Pressure Flows; Amplified Thermionic Cooling Using Arrays of Nanowires; Delamination-Indicating Thermal Barrier Coatings; Preventing Raman Lasing in High-Q WGM Resonators; Procedures for Tuning a Multiresonator Photonic Filter; Robust Mapping of Incoherent Fiber-Optic Bundles; Extended-Range Ultrarefractive 1D Photonic Crystal Prisms; Rapid Analysis of Mass Distribution of Radiation Shielding; Modeling Magnetic Properties in EZTB; Deep Space Network Antenna Logic Controller; Modeling Carbon and Hydrocarbon Molecular Structures in EZTB; BigView Image Viewing on Tiled Displays; and Imaging Sensor Flight and Test Equipment Software.

Source record↗

Capaciflector camera

A capacitive type proximity sensor having improved range and sensitivity between a surface and an intruding object in the vicinity of the surface having a voltage source, a number of outer electrical conductors on the surface with each forming one electrode of a number of sensor capacitors, the other electrode for each sensor capacitor being the object. The outer conductors are made from thin sheets of conductive material covered with insulation. An intermediate electrical conductor is located between the outer conductors and the surface and is of a size larger than the outer conductors to act as a shield for reducing the parasitic capacitance between the outer conductors and the surface. The intermediate conductor is also made from a thin sheet of conductive material covered with insulation. The outer conductors and the intermediate conductor are attached to the surface with no gap between the insulation on the conductors and no gap between the surface and the insulation on intermediate conductor, the outer conductors and the intermediate conductor conjoining with each other and with the surface, with the surface acting as a ground plane. A current-measuring voltage follower circuit is connected to the voltage source for coupling in phase and amplitude the instantaneous voltage at the voltage source to the outer electrical conductors and the intermediate electrical conductor. This circuit is responsive to the change in capacitance of the sensor capacitors and generates a number of output signals.

Vranish, John M.↗

Capaciflector camera

A capacitive type proximity sensor having improved range and sensitivity between a surface and an intruding object in the vicinity of the surface having a voltage source, a number of outer electrical conductors on the surface with each forming one electrode of a number of sensor capacitors, the other electrode for each sensor capacitor being the object is described. The outer conductors are made from thin sheets of conductive material covered with insulation. An intermediate electrical conductor is located between the outer conductors and the surface and is of a size larger than the outer conductors to act as a shield for reducing the parasitic capacitance between the outer conductors and the surface. The intermediate conductor is also made from a thin sheet of conductive material covered with insulation. The outer conductors and the intermediate conductor are attached to the surface with no gap between the insulation on the conductors and no gap between the surface and the insulation on intermediate conductor, the outer conductors and the intermediate conductor conjoining with each other and with the surface, with the surface acting as a ground plane. A current-measuring voltage follower circuit is connected to the voltage source for coupling in phase and amplitude the instantaneous voltage at the voltage source to the outer electrical conductors and the intermediate electrical conductor. This circuit is responsive to the change in capacitance of the sensor capacitors and generates a number of output signals.

Vranish, John M.↗

Search Technology for Optimal Rescue Missions (STORM)

Natural disasters, such as earthquakes, hurricanes, and wildfires are responsible for the deaths of 60,000 to 90,000 people per year. Today, search and rescue (SAR) operations heavily rely on humans to find and deliver life-saving supplies to those affected by these disasters. However, these operations have limits in visibility, navigation, communication systems, and data availability in the area affected, as well as endangering the SAR personnel. Search Technology for Optimal Rescue Missions (STORM) discusses a new system for SAR teams using autonomous drones able to find and deliver supplies to people, without risking more lives in the process. The concept includes the use of two drone types, STORM Search and STORM Rescue, which will survey and locate survivors and be able to drop equipment to the survivors identified, respectively. These two types of drones were optimized in drone design and durability (such as the use of dihedral wings and a toroidal propeller), detection and navigation systems (sturdy thermal and Light Detection and Ranging [LiDAR] cameras), automation and system design (Machine Learning and Computer Vision), server-drone communication (Meshnets), weight, and cost. Once implemented, the STORM concept is expected to improve, ease, and speed up SAR operations, and most important of all, rescue lives that would have never been currently possible to find.

Astha Ingole↗

Retrieval of H2O Abundance in Titan's Stratosphere: A (Re)Analysis of CIRS/Cassini and PACS/Herschel Observations

Since its first measurement 20 years ago by the Infrared Space Observatory (ISO), the water (H2O) mole fraction in Titan’s stratosphere remains uncertain due to large differences between the determinations from available measurements. More particularly, the recent measurements made from the Herschel observatory (PACS (Photodetector Array Camera and Spectrometer) and HIFI (Heterodyne Instrument for the Far Infrared)) estimated the H2O mole fraction to be 0.023 parts per billion at 12.1 millibars. A mixing ratio of 0.14 parts per billion at 10.7 millibars was, however, retrieved from nadir spatially-resolved observations of Cassini/CIRS (Composite Infrared Spectrometer). At the same pressure level (10.7 millibars), this makes a difference of a factor of 5.5 between PACS and CIRS measurements, and this has notably prevented current models from fully constraining the oxygen flux flowing into Titan’s atmosphere. In this work, we try to understand the differences between the H2O mole fractions estimated from Herschel/PACS and Cassini/CIRS observations. The strategy for this is to 1) analyse recent disc-averaged observations of CIRS to investigate if the observation geometry could explain the previous observed differences, and 2) (re)analyse the three types of observation with the same retrieval scheme to assess if previous differences in retrieval codes/methodology could be responsible for the previous discrepancies. With this analysis, we show that using the same retrieval method better reconcile the previous measurements of these instruments. However, the addition of the disc-averaged CIRS observations, instead of confirming the consistency between the different datasets, reveals discrepancies between one of the CIRS disc-averaged set of observations and PACS measurements. This raises new questions regarding the possibility of latitudinal variations of H2O, which could be triggered by seasonal changes of the meridional circulation. As it has already been shown for nitriles and hydrocarbons, this circulation could potentially impact the latitudinal distribution of H2O through the subsidence or up- welling of air rich in H2O. The possible influence of spatial/time variations of the OH/H2O input flux in Titan’s atmosphere is also discussed. The analysis of more observations will be needed in future work to address the questions arising from this work and to improve the understanding of the sources of H2O in Titan’s atmosphere.

Bauduin, S.↗

High spatial resolution observations of NGC 7027 with a 10 micron array camera

First observations of a planetary nebula with an infrared charge injection device (CID) array camera are reported. The 10 micron images of NGC 7027 have spatial resolution comparable to that of the highest resolution (less than 2 arcsec) radio aperture-synthesis maps of this source. A much closer correspondence between the mid-infrared and radio appearance of NGC 7027 was found than was known previously, confirming that warm dust is coextensive and well mixed with the gas in the ionized zone. Using maps at three wavelengths, the spatial dependence of the shape of the 8-13 micron spectrum within the nebula is examined. The dip at 9.60 microns is shallowest in regions of enhanced optical extinction (as determined from new images near 4000 and 9000 A obtained with an optical charge coupled device). The 9.60 micron emission is strongest in these same positions. It is shown that the results may be explained not by silicate absorption, but by a combination of emission from two distinct grain populations, one of which is also partly responsible for the variation in extinction across the nebula.

Arens, J. F.↗