Search NASA⌕ Search

SEARCH · Search NASA

Results for “coherent diffractive imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Signatures of electronic and nuclear coherences in ultrafast molecular x-ray and electron diffraction

Femtosecond x-ray and electron diffraction hold promise to image the evolving structures of single molecules. We present a unified quantum-electrodynamical formulation of diffraction signals, based on the exact many-body nuclear + electronic wavefunction that can be extracted from quantum chemistry simulations. This gives a framework for analyzing various approximate molecular dynamics simulations. We show that the complete description of ultrafast diffraction signals contains interesting contributions involving mixed elastic and inelastic scattered photons that are usually masked by other larger contributions and are neglected. These terms include overlaps of nuclear wavepackets between different electronic states that provide an electronic decoherence mechanism and are important for the time-resolved imaging of conical intersections.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coherent Cone-Beam X-ray Microscopy

A novel full-field imaging method using the (111) Bragg diffraction of a sub-micron gold crystal as the divergent cone-beam for sample illumination is reported. The divergence of the illumination allows for very high magnification, limited only by the achievable ratio of the crystal-to-sample and sample-to-detector distances. In this case an x-ray magnification of approximately 115 was achieved.

43 PARTICLE ACCELERATORS↗

Ultrafast self-gating Bragg diffraction of exploding nanocrystals in an X-ray laser

In structural determination of crystalline proteins using intense femtosecond X-ray lasers, damage processes lead to loss of structural coherence during the exposure. We use a nonthermal description for the damage dynamics to calculate the ultrafast ionization and the subsequent atomic displacement. These effects degrade the Bragg diffraction on femtosecond time scales and gate the ultrafast imaging. This process is intensity and resolution dependent. At high intensities the signal is gated by the ionization affecting low resolution information first. At lower intensities, atomic displacement dominates the loss of coherence affecting high-resolution information. We find that pulse length is not a limiting factor as long as there is a high enough X-ray flux to measure a diffracted signal.

47 OTHER INSTRUMENTATION↗

Deterministic nanoscale quantum spin-defect implantation and diffraction strain imaging

Abstract Local crystallographic features negatively affect quantum spin defects by changing the local electrostatic environment, often resulting in degraded or varied qubit optical and coherence properties. Few tools exist that enable the deterministic synthesis and study of such intricate systems on the nano-scale, making defect-to-defect strain environment quantification difficult. In this paper, we highlight state-of-the-art capabilities from the U.S. Department of Energy’s Nanoscale Science Research Centers that directly address these shortcomings. Specifically, we demonstrate how complementary capabilities of nano-implantation and nano-diffraction can be used to demonstrate the quantum relevant, spatially deterministic creation of neutral divacancy centers in 4H silicon carbide, while investigating and characterizing these systems on the ≤ 25 nm scale with strain sensitivities on the order of 1 × 10 − 6 , relevant to defect formation dynamics. This work lays the foundation for ongoing studies into the dynamics and deterministic formation of low strain homogeneous quantum relevant spin defects in the solid state.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Observations of Shock-Loaded Tin and Zirconium Surfaces with Single-Pulse X-ray Diffraction

A single-pulse X-ray diffraction (XRD) diagnostic has been developed for the investigation of shocked material properties on a very short time scale. The diagnostic, which consists of a 37-stage Marx bank high-voltage pulse generator coupled to a needle-and-washer electron beam diode via coaxial cable, produces line-and-bremsstrahlung X-ray emission in a 40 ns pulse. The molybdenum anode produces 0.71 Å characteristic K lines used for diffraction. The X-ray beam passes through a pinhole collimator and is incident on the sample with an approximately 2 mm×5 mm spot and 1° full width at half maximum angular divergence. Coherent scattering from the sample produces a Debye-Scherrer diffraction pattern on an image plate located at 75 mm from the polycrystalline sample surface. An experimental study of the polycrystalline structures of zirconium and tin under high-pressure shock loading has been conducted with single-pulse XRD. The experimental targets were 0.1-mm-thick foils of zirconium and tin using 0.4-mm-thick vitreous carbon back windows for shock loading, and the shocks were produced by either Detasheet or PBX-9501 high explosives buffered by 1-mm-thick 6061-T6 aluminum. The diffraction patterns from both shocked zirconium and tin indicated a phase transition into a polymorphic mix of amorphous and new solid phases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single-view phase retrieval of an extended sample by exploiting edge detection and sparsity

We propose a new approach to robustly retrieve the exit wave of an extended sample from its coherent diffraction pattern by exploiting sparsity of the sample's edges. This approach enables imaging of an extended sample with a single view, without ptychography. We introduce nonlinear optimization methods that promote sparsity, and we derive update rules to robustly recover the sample's exit wave. We test these methods on simulated samples by varying the sparsity of the edge-detected representation of the exit wave. Finally, our tests illustrate the strengths and limitations of the proposed method in imaging extended samples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical performance of synthetic aperture telescope configurations

The diffraction-limited performances of synthetic aperture configuration arrays of four telescopes, used for coherent imaging or beam transmission, are calculated and compared. The optical performance of phased telescope arrays was found to be more sensitive to rms piston errors than to rms tilt errors. Image degradation due to pupil mapping errors imposes tight tolerances upon the structural integrity of the telescope. One part in 10,000 pupil mapping error limits the field-of-view to approximately 30 arcsec. Field curvature of the independent telescopes provides a fundamental limit to the field-of-view for phased arrays made up of two-mirror telescopes. These field-of-view limitations may profoundly affect target acquisition, tracking, or imaging applications.

Harvey, J. E.↗

2D grating simulation for X-ray phase-contrast and dark-field imaging with a Talbot interferometer

Talbot interferometry is a recently developed and an extremely powerful X-ray phase-contrast imaging technique. Besides giving access to ultra-high sensitivity differential phase contrast images, it also provides the dark field image, which is a map of the scattering power of the sample. In this paper we investigate the potentialities of an improved version of the interferometer, in which two dimensional gratings are used instead of standard line grids. This approach allows to overcome the difficulties that might be encountered in the images produced by a one dimensional interferometer. Among these limitations there are the phase wrapping and quantitative phase retrieval problems and the directionality of the differential phase and dark-field signals. The feasibility of the 2D Talbot interferometer has been studied with a numerical simulation on the performances of its optical components under different circumstances. The gratings can be obtained either by an ad hoc fabrication of the 2D structures or by a superposition of two perpendicular linear grids. Through this simulation it has been possible to find the best parameters for a practical implementation of the 2D Talbot interferometer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Elimination of coherent noise in a coherent light imaging system

Optical imaging systems using coherent light introduce objectionable noise into the output image plane. Dust and bubbles on and in lenses cause most of the noise in the output image. This noise usually appears as bull's-eye diffraction patterns in the image. By rotating the lens about the optical axis these diffraction patterns can be essentially eliminated. The technique does not destroy the spatial coherence of the light and permits spatial filtering of the input plane.

Grebowsky, G. J.↗

Imaging transient melting of a nanocrystal using an X-ray laser

Significance Despite phase transitions, such as melting, being ubiquitous in nature, understanding what occurs at the nanoscale (such as in nanocrystals) has so far remained challenging. With ensemble studies of nanocrystals it is often difficult to discriminate between intrinsic size-dependent properties and effects due to sample size and shape dispersity. Here, using an X-ray free electron laser we image the reversible melting of an individual nanocrystal induced by an ultrashort laser. It is revealed that the melting occurs transiently, repeatably, and inhomogeneously. This is consistent with a core-shell model where the exterior is melted and a solid core remains. These findings reveal, unambiguously, that core-shell melting occurs, which has important implications for understanding nanoscale phenomena.

Clark, Jesse N.↗

Multifrequency parallelized near-field optical imaging with anistropic metal-dielectric stacks

Metal-dielectric stacks can be designed to support resonant transmission modes for certain evanescent field components of an incident electromagnetic field. Here we show that when combined with an appropriate subwavelength pitch grating the amplified Fourier components coincide with different diffraction orders at different frequencies. It thereby becomes possible to collect a wide range of evanescent Fourier components by performing measurements at different optical frequencies. For a typical anisotropic metal-dielectric stack, we find that for a source emitting at wavelengths 400-500 nm, imaging with a resolution of {approx_equal}20 nm becomes possible. Although the reconstructed image contains ringing effects due to gaps in the measured Fourier spectrum, the final resolution achievable is a significant improvement over other fast near-field imaging techniques. The presented technique may find applications in fast super-resolution surface imaging of objects that emit over a wider optical frequency range.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hybrid quantitative simulation on the in-line phase-contrast x-ray imaging of three dimensional samples under actual clinic imaging parameters

A hybrid model combining Monte Carlo method with diffraction theory of wave optics has been developed and applied to quantitatively simulate the in-line diffractive phase-contrast x-ray imaging of three dimensional tissue samples under actual clinic imaging parameters. The primary microcosmic interactions of medical-energy x-ray within matter including photoabsorption, Compton scattering, and coherent scattering, have been taken into account in the Monte Carlo simulation. A diffraction processing based on Fresnel diffraction theory is carried out to simulate the macroscopic diffraction effect. A comparison with experiment results has also been performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SEARCHING FOR SUB-KILOMETER TRANS-NEPTUNIAN OBJECTS USING PAN-STARRS VIDEO MODE LIGHT CURVES: PRELIMINARY STUDY AND EVALUATION USING ENGINEERING DATA

We present a pre-survey study of using the Panoramic Survey Telescope and Rapid Response System (Pan-STARRS) high sampling rate video mode guide star images to search for trans-Neptunian objects (TNOs). Guide stars are primarily used by Pan-STARRS to compensate for image motion and hence improve the point-spread function. With suitable selection of the guide stars within the Pan-STARRS 7 deg{sup 2} field of view, the light curves of these guide stars can also be used to search for occultations by TNOs. The best target stars for this purpose are stars with high signal-to-noise ratio (S/N) and small angular size. In order to do this, we compiled a catalog using the S/N calculated from stars with m{sub V} < 13 mag in the Tycho2 catalog, then cross matched these stars with the Two Micron All Sky Survey catalog, and estimated their angular sizes from (V - K) color. We also outlined a new detection method based on matched filter that is optimized to search for diffraction patterns in the light curves due to occultation by sub-kilometer TNOs. A detection threshold is set to compromise between real detections and false positives. Depending on the theoretical size distribution model used, we expect to find up to a hundred events during the three-year lifetime of the Pan-STARRS-1 project. The high sampling (30 Hz) of the project facilitates detections of small objects (as small as 400 m), which are numerous according to power-law size distribution, and thus allows us to verify various models and further constrain our understanding of the structure in the outer reach of the solar system. We have tested the detection algorithm and the pipeline on a set of engineering data (taken at 10 Hz instead of 30 Hz). No events were found within the engineering data, which is consistent with the small size of the data set and the theoretical models. Meanwhile, with a total of {approx}22 star-hours video mode data (|{beta}| < 10{sup 0}), we are able to set an upper limit of N(>0.5 km) {approx} 2.47 x 10{sup 10} deg{sup -2} at 95% confidence limit.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray microscopy and talbot imaging with the matter in extreme conditions X-ray imager at LCLS

The last decade has shown the great potential that X-ray Free Electron Lasers (FEL) have to study High Energy Density (HED) physics. Experiments at FELs have made significant breakthroughs in Shock Physics and Dynamic Diffraction, Dense Plasma Physics and Warm Dense Matter Science, using techniques such as isochoric heating, inelastic scattering, small angle scattering and X-ray diffraction. In addition, and complementary to these techniques, the coherent properties of the FEL beam can be used to image HED samples with high fidelity. We present new imaging diagnostics and techniques developed at the Matter in Extreme Conditions (MEC) instrument at Linac Coherent Light Source (LCLS) over the last few years. We show results in Phase Contrast Imaging geometry, where the X-ray beam propagates from the target to a camera revealing its phase, as well as in Direct Imaging geometry, where a real image of the sample plane is produced in the camera with a spatial resolution down to 200 nm. Last, we show an implementation of the Talbot Imaging method allowing both X-ray phase and intensity measurements change introduced by a target with sub-micron resolution.

47 OTHER INSTRUMENTATION↗

Asymmetric nanoparticle oxidation observed in-situ by the evolution of diffraction contrast

Abstract The use of transmission electron microscopy (TEM) to observe real-time structural and compositional changes has proven to be a valuable tool for understanding the dynamic behavior of nanomaterials. However, identifying the nanoparticles of interest typically require an obvious change in position, size, or structure, as compositional changes may not be noticeable during the experiment. Oxidation or reduction can often result in subtle volume changes only, so elucidating mechanisms in real-time requires atomic-scale resolution or in-situ electron energy loss spectroscopy, which may not be widely accessible. Here, by monitoring the evolution of diffraction contrast, we can observe both structural and compositional changes in iron oxide nanoparticles, specifically the oxidation from a wüstite-magnetite (FeO@Fe 3 O 4 ) core – shell nanoparticle to single crystalline magnetite, Fe 3 O 4 nanoparticle. The in-situ TEM images reveal a distinctive light and dark contrast known as the ‘Ashby-Brown contrast’, which is a result of coherent strain across the core – shell interface. As the nanoparticles fully oxidize to Fe 3 O 4 , the diffraction contrast evolves and then disappears completely, which is then confirmed by modeling and simulation of TEM images. This represents a new, simplified approach to tracking the oxidation or reduction mechanisms of nanoparticles using in-situ TEM experiments.

36 MATERIALS SCIENCE↗

Sub-pixel high-resolution imaging of high-energy x-rays inspired by sub-wavelength optical imaging

We have developed and demonstrated an image super-resolution method—XR-UNLOC: X-Ray UNsupervised particle LOCalization—for hard x-rays measured with fast-frame-rate detectors that is an adaptation of the principle of photo-activated localization microscopy (PALM) and stochastic optical reconstruction microscopy (STORM), which enabled biological fluorescence imaging at sub-optical-wavelength scales. We demonstrate the approach on experimental coherent Bragg diffraction data measured with 52 keV x-rays from a nanocrystalline sample. From this sample, we resolve the fine fringe detail of a high-energy x-ray Bragg coherent diffraction pattern to an upsampling factor of 16 of the native pixel pitch of 30 μ m of a charge-integrating fastCCD detector. This was accomplished by analysis of individual photon locations in a series of “nearly-dark” instances of the diffraction pattern that each contain only a handful of photons. Central to our approach was the adaptation of the UNLOC photon fitting routine for PALM/STORM to the hard x-ray regime to handle much smaller point spread functions, which required a different statistical test for photon detection and for sub-pixel localization. A comparison to a photon-localization strategy used in the x-ray community (“droplet analysis”) showed that XR-UNLOC provides significant improvement in super-resolution. We also developed a metric by which to estimate the limit of reliable upsampling with XR-UNLOC under a given set of experimental conditions in terms of the signal-to-noise ratio of a photon detection event and the size of the point spread function for guiding future x-ray experiments in many disciplines where detector pixelation limits must be overcome.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microstructural features and domain formation in (Ba,Sr){sub 2}TiSi{sub 2}O{sub 8} fresnoites

The formation and co-existence of crystallographically modulated and non-modulated regions in (Ba,Sr){sub 2}TiSi{sub 2}O{sub 8} fresnoites is reviewed, particularly the dependence on local composition. It is shown that perturbations of the average fresnoite structure, determined from appreciable single crystals, are in some cases better described as nanometric domain intergrowths where departures from ideal stoichiometry are characteristics of incommensuration, while modulation is absent from volumes that are less perturbed chemically. Evidence for this differentiation is obtained from selected area electron diffraction (SAED) patterns and high-resolution transmission electron microscopy (HRTEM) images. The domains are readily distinguished by their unique contrast in bright field electron micrographs. Fourier reconstructions of HRTEM images collected from areas with darker contrast show that modulation can change within relatively small volumes. Nearby areas with lighter contrast were found by SAED to be free of structural disorder and incommensurate reflections. - Graphical abstract: Fresnoite layers contain SiO{sub 4} and TiO{sub 5} polyhedra that undergo run rotation and tilting to create 3D, 4D and 5D structural modulations that can be directly observed by electron diffraction and high resolution imaging. Highlights: {yields}(Ba,Sr){sub 2}TiSi{sub 2}O{sub 8} fresnoites contain commensurate and incommensurate domains. > Departures in stoichiometry promote the formation of nanostructured domains. > Domains formation may provide a means for reducing strain in single crystals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗