Search NASA⌕ Search

SEARCH · Search NASA

Results for “core optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

437 records · Page 25

Regolith Volatile Characterization (RVC) in RESOLVE

Resource investigation in the lunar poles is of importance to the potential impact of in-situ resource utilization (ISRU). The RESOLVE project developed a payload to investigate the permanently shadowed areas of the lunar poles and demonstrate ISRU technology. As a part of the RESOLVE project, the regolith volatile characterization (RVC) subsystem was designed to examine the release of volatiles from sample cores. The test sample was heated in the reactor to release the volatiles where they were analyzed with gas chromatography. Subsequently, the volatile sample was introduced into the lunar water resource demonstration (LWRD) subsystem where the released hydrogen and water were selectively captured. The objective of the Regolith Volatile Characterization (RVC) subsystem was to heat the crushed core sample and determine the desorption of volatile species of interest. The RVC subsystem encompasses the reactor and the system for volatile analysis. The system was designed to analyze H2, He, CO, CO2, N2, 02, CH4, H2S and H2O. The GC chosen for this work is a Siemens MicroSAM process GC with 3 columns and 8 TCD detectors. Neon was chosen as the carrier gas to enhance the analysis of hydrogen and helium.The limit of detection for the gases is approx.1000ppm for H2, CO. CO2 , N2, O2 and H2 S. The limit of detection for CH4 is approx.4000ppm and the water limit of detection is -10000 ppm with a sample analysis time of 2-3 minutes. These values (with the exception of water and H2S) were determined by dilution of a six gas mixture from Scott Gas (5% CO2, CO, O2, N2, 4% CH4 and H2) using mass flow controllers (MFC5). Water was calibrated at low levels using an in house relative humidity (RH) generator. H 2S and high concentrations of H2 were calibrated by diluting a pure stream of gas with MFCs. Higher concentrations of N2 and 02 were calibrated using Air again diluting with MFCs. There were three modification goals for the GC in EBU2 that would allow this process GC to be used in the field demo for RESOLVE. The first modification was to decrease the weight associated with the GC, this included eliminating the explosion proof case (Figure 1) and replacing it with a lightweight case as well as using an on board COPV tank for the neon carrier gas. The next goal was to add a second oven for the molecular sieve column to allow for dual temperature control during GC operation; the separation of hydrogen and helium is optimum at lower temperatures while the water analysis required higher temperatures creating a competing design requirement. The second oven also allows a lower limit of detection for water quantification and avoids the possibility of water condensing in the GC which could ruin the column characteristics. The final goal was to modify the column arrangement to optimize the system for our specific application. Figure 2 shows the internal details of the module optimized optimized for our field application. The modifications and performance of the gas analysis system will be discussed in detail.

Captain, Janine↗

Modeling and Simulation of the Angel Upper Limb Offload Device: Branching Into New Methods

BACKGROUND: The Active Response Gravity Offload System (ARGOS) provides an analog environment for extravehicular activity (EVA) testing and training. Discomfort has been observed during longer suited test sessions. While the subject’s core is offloaded during surface EVA evaluations, his/her arms experience full Earth gravity and can become overly fatigued, especially during suited tests which involve reaching and prolonged arm extensions. A device (ARGOS Negation of Gravitational Effects on the Limbs: ANGEL) to offload the weight of the arms and suit sleeves is being developed by JSC’s Flight Systems Branch of the Software, Robotics, and Simulation Division. Previously we have shared preliminary modeling of that device and kinematics based on motion capture data. Here we present an alternative approach to determine device kinematics by calculating ANGEL component angles with an OpenSim plugin. We compare calculated angles to inverse kinematics (IK) derived ones with the goal of validating the model. This new method can be further informative for device design and analytically testing different configurations to achieve desired reduced gravity conditions (e.g., lunar gravity (Lg) or Martian gravity (Mg)). We have compared calculated angles with IK-derived angles in tests with a shirt-sleeve subject positioned in a test stand with a Mark-III Hard Upper Torso (HUT) and Portable Life Support System (PLSS) mockup and arm weights to emulate the weight of the suit sleeve as well as a suited subject in ARGOS with a Mark-III suit. A variety of upper body tasks were completed in the former and full-body tasks in the latter. METHODS AND RESULTS: To model the offload device, we augment the OpenSim human model topology with the offload mechanism components and joints, using CAD models to represent the mechanism graphically. The joint angles of the device are calculated in the OpenSim plugin by modeling how the components configure themselves under the offloading spring tension given a particular IK-derived arm position. There are four ANGEL components with a total of 5 degrees of freedom (DOFs), each component has a single DOF except for the cuff which is modeled as 2 DOFs. The sickle/yaw bracket and cuff rotation angles are determined statically based on the assumptions that the sickle will track the attachment point of the cuff and that the cuff will rotate such that the attachment point is at its highest point. The cuff tilt, linker and V-bracket angles are then determined by optimizing their positions to approach a mechanical equilibrium. The calculated linker angle is compared to three different methods of determining the linker line-of-force kinematically (from V-bracket to center-cuff, cuff highest point or marker-derived position). Given the joint angles of the device, the spring force and resulting force on the arm is computed by the plugin and applied as an external load in inverse dynamics (ID) to enable study of overall shoulder joint torques as well as offload achieved. We verify the calculated joint angles by using the inverse kinematic data. The average difference in angles is the smallest for the V-bracket and linker, around 1 to 5 degrees for most trials. The resulting offload and shoulder torque are comparable between calculated and IK-derived angles. In summary, we have developed a method to calculate the joint angles of an exoskeleton-like upper limb offloading device currently in development. We have also developed a custom plugin which will be a valuable tool to optimize device configurations for a desired gravitational environment, probe the offload achieved for motions recorded outside of our test suite, and inform future design improvements.

L B Nilsson↗

Modeling and Simulation of The Angel Upper Limb Offload Device: Branching into New Methods

BACKGROUND: The Active Response Gravity Offload System (ARGOS) provides an analog environment for extravehicular activity (EVA) testing and training. Discomfort has been observed during longer suited test sessions. While the subject’s core is offloaded during surface EVA evaluations, his/her arms experience full Earth gravity and can become overly fatigued, especially during suited tests which involve reaching and prolonged arm extensions. A device (ARGOS Negation of Gravitational Effects on the Limbs: ANGEL) to offload the weight of the arms and suit sleeves is being developed by JSC’s Flight Systems Branch of the Software, Robotics, and Simulation Division. Previously we have shared preliminary modeling of that device and kinematics based on motion capture data. Here we present an alternative approach to determine device kinematics by calculating ANGEL component angles with an OpenSim plugin. We compare calculated angles to inverse kinematics (IK) derived ones with the goal of validating the model. This new method can be further informative for device design and analytically testing different configurations to achieve desired reduced gravity conditions (e.g., lunar gravity (Lg) or Martian gravity (Mg)). We have compared calculated angles with IK-derived angles in tests with a shirt-sleeve subject positioned in a test stand with a Mark-III Hard Upper Torso (HUT) and Portable Life Support System (PLSS) mockup and arm weights to emulate the weight of the suit sleeve as well as a suited subject in ARGOS with a Mark-III suit. A variety of upper body tasks were completed in the former and full-body tasks in the latter. METHODS AND RESULTS: To model the offload device, we augment the OpenSim human model topology with the offload mechanism components and joints, using CAD models to represent the mechanism graphically. The joint angles of the device are calculated in the OpenSim plugin by modeling how the components configure themselves under the offloading spring tension given a particular IK-derived arm position. There are four ANGEL components with a total of 5 degrees of freedom (DOFs), each component has a single DOF except for the cuff which is modeled as 2 DOFs. The sickle/yaw bracket and cuff rotation angles are determined statically based on the assumptions that the sickle will track the attachment point of the cuff and that the cuff will rotate such that the attachment point is at its highest point. The cuff tilt, linker and V-bracket angles are then determined by optimizing their positions to approach a mechanical equilibrium. The calculated linker angle is compared to three different methods of determining the linker line-of-force kinematically (from V-bracket to center-cuff, cuff highest point or marker-derived position). Given the joint angles of the device, the spring force and resulting force on the arm is computed by the plugin and applied as an external load in inverse dynamics (ID) to enable study of overall shoulder joint torques as well as offload achieved. We verify the calculated joint angles by using the inverse kinematic data. The average difference in angles is the smallest for the V-bracket and linker, around 1 to 5 degrees for most trials. The resulting offload and shoulder torque are comparable between calculated and IK-derived angles. In summary, we have developed a method to calculate the joint angles of an exoskeleton-like upper limb offloading device currently in development. We have also developed a custom plugin which will be a valuable tool to optimize device configurations for a desired gravitational environment, probe the offload achieved for motions recorded outside of our test suite, and inform future design improvements.

L B Nilsson↗

Risk of Performance and Behavioral Health Decrements Due to Inadequate Cooperation, Coordination, and Psychosocial Adaptions within a Team

The Risk of Performance and Behavioral Health Decrements Due to Inadequate Cooperation, Coordination, Communication, and Psychosocial Adaptation within a Team (the Team Risk) is primarily performance-focused, with a secondary emphasis on behavioral health outcomes resulting from team performance and interpersonal interactions. Monitoring tools, measures, and countermeasures are aimed at enhancing team processes and team composition configurations to optimize team performance and functioning. Long-duration exploration missions (LDEMs) will include major challenges that could affect team performance, including social isolation, physical confinement, a small and diverse crew, communication delays between crew and ground, limited or no crew rotation or evacuation options, limited or no resupply, and a high-consequence environment. Each of these conditions will affect the crew’s coordination, cooperation, psychological well-being, and performance. Although the International Space Station (ISS) remains important for studies that require spaceflight testing and validation, the current conditions on the ISS do not adequately mimic the exploration environment that is required for National Aeronautics and Space Administration (NASA) teams research, and thus access to terrestrial or ground-based analogs of LDEM conditions is paramount. The emphasis on analogs for research is reflected in this updated evidence review of the Team Risk, and includes data from studies conducted at isolated, confined, extreme (ICE) environments (e.g., Antarctic stations), and from several mission simulation analogs such as the Human Exploration Research Analog (HERA) (HERA Experiment Information Package, 2014), also known as isolated, confined, controlled (ICC) environments. These studies have characterized many team factors regarding LDEMs, and the Team Risk has now matured from risk characterization to focusing more on countermeasure development. Because spaceflight evidence for team-level research is lacking, no reliable data is available to quantify the impact of team-level variables on individual and team-level outcomes during spaceflight missions. Until recently, no systematic attempt had been undertaken to measure the performance effects of team cohesion, team composition, team training, or team-related psychosocial adaptation during spaceflight. The Team Risk is a relatively young research area for NASA, with substantial growth only since the 2000s, and with limited access to spaceflight performance data. As a result, spaceflight evidence is lacking to identify specifically what team composition, level of training, amount of cohesion, or quality of psychosocial adaptation is necessary to reduce the risk of performance errors in space. However, astronaut journals and interviews and reports from spaceflight subject matter experts (SMEs) provide testimonies that team performance during spaceflight is important for mission success and to maintain crew health. Team spaceflight data is now being collected as part of the Spaceflight Standard Measures task (Clement, 2021)—a set of core measurements related to many human spaceflight risks that are collected from astronauts before, during, and after long-duration missions. The team-related standard measures focus on team cohesion, team performance, group living, team climate, and team processes. Collection of standard measures data is ongoing and published data is not yet available. Finally, although spaceflight evidence is lacking, evidence gleaned from ground studies and spaceflight analog studies will help close the gaps outlined in the Team Risk. Ground-based studies provide quantitative evidence for team functioning in ICE environments. Academic research on teams has produced dozens of meta-analyses that can be used to understand the general relationships among team inputs (e.g., team member characteristics and skills, job context), team processes, and emergent states (e.g., coordination, communication, cooperation, cohesion, trust, shared cognition), and team outcomes (e.g., effectiveness, errors, adaptation). Teams are complex, incorporating individual characteristics of team members, but also existing at a level that is greater than the sum of its parts. Therefore, the Team Risk must be integrated with other individual-focused NASA Human Research Program (HRP) risks, including Behavioral Medicine (BMed), Sleep, and Human-Systems Integration Architecture (HSIA), and emerging research indicates more integration may needed between the Team Risk and the physiologically oriented risks. Much of this integration occurs through the Human Systems Risk Board (HSRB). A lack of team functioning may be a stressor in some circumstances, but the team often acts as a countermeasure. For example, support for team leaders and teammates can facilitate individual functioning and encourage psychological and physically healthy behaviors and attitudes. However, more research is needed regarding teams during LDEMs and the remaining gaps in the research are described in the current report.

Lauren Blackwell Landon↗

Does Collection Time Bias the Ecology of Cleanroom Air Samples?

Microbial monitoring of astromaterials collections has taken on increased importance with the return of biologically sensitive samples from the asteroids Ryugu and Bennu and the initiation of the Mars Sample Return Program. Terrestrial bacteria and fungi can alter the mineralogy and organic composition of our collections causing irreversible contamination of pristine samples and increasing the risk of false positives for life detection measurements. NASA has conducted routine microbial monitoring of its existing collections since 20181. Initial monitoring focused on surface samples collected with foam swabs. Although, airborne microbiology is often decoupled from surface microbiology in the built environment2 culture-based air sampling techniques like impactors were not compliant with existing contamination control requirements. Bringing organic rich media, gelatin or liquids into curation cleanrooms presents an unacceptable risk to pristine samples. In 2022 NASA purchased a materials complaint air sampler and began collecting air samples from the cleanrooms in addition to surface samples3. The new instrument uses an electret filter to collect samples that are suitable for cultivating organisms or for direct DNA sequencing. Preliminary DNA sequencing results appeared to indicate that longer sampling times biased the microbial community in favor of hearty, spore-forming bacteria3. We present the results of a study comparing overnight sampling (17 hours) to short (1 hour) sampling of unoccupied curation cleanrooms. The results will help us optimize our monitoring protocols and develop a more detailed inventory of the ecology of astromaterials curation cleanrooms. Methods: We analyzed 72 paired air samples from six different cleanrooms including the meteorite processing lab (ISO 7 equivalent, 16 samples), the lunar lab (ISO 6 equivalent, 10 samples), the stardust lab (ISO 5 equivalent 14 samples), the OSIRIS-REx lab (ISO 5 equivalent, 12 samples), the Hayabusa2 lab (ISO 5 equivalent, 14 samples), and the Genesis lab (ISO 4 equivalent, 6 samples). All the samples were collected with an InnovaPrep Bobcat air sampler operating at a sampling rate of 200 L/min. The sampler operates for 5 minutes out of every 20 minute period. Half of the samples were collected by filtering 3,000L (15 min. of active sampling) of air across an electret filter for one hour. The rest of the samples were collected by filtering approximately 51,000 L air across the filter overnight (~17 hours, 255 min. of active sampling). Cells were eluted from the filter using 6-7 ml of pressurized 0.15% tween 20 in PBS (phosphate buffered saline). This liquid was used to cultivate bacteria according to previously published methods1,4,5 and for DNA extraction and next generation sequencing. DNA was extracted with a Qiagen MagAttract PowerMicrobiome kit6. To identify bacteria and archaea, the 16S rRNA gene was amplified using Earth Microbiome primers for the V4 region 7. The amplified DNA was sequenced on an Illumina MiSeq using a V3 reagent kit. The resulting sequences were processed using DADA2 and QIIME2 as implemented on the EDGE bioinformatics platform8–10. Results: Only two of the 72 samples had no amplifiable DNA. Amplified DNA concentrations ranged from 2.67 – 0.272 ng/µl. The median concentration of amplified DNA for the 1 hour samples was 0.770 ± 0.368 ng/µl. The median concentration of amplified DNA for the overnight samples was 0.877 ± 0.434 ng/µl. On average the overnight samples had slightly more sequences (58,960 vs. 59,456) and ASV’s (amplicon sequence variants) (60 vs 64.5) than the one hour samples, but these differences are not statistically significant. The most abundant ASV in every sample mapped to the genus Cupravidus. ASV’s mapping to the genuses Bacillus, Schlegelella, Thermus, and Staphylococcus were also common. Discussion and Future Work: Alpha diversity statistics like Shannon Entropy and Faith Phylogenetic Diversity are used to describe the diversity of organisms in a single sample. If a longer sampling time was biasing the data, we would expect to see a change in these diversity statistics vs. sample time. However, we did not observe this in our data. The median Shannon entropy was slightly higher for the overnight samples (3.773 vs 3.611) as was the Faith Phylogenetic Diversity (4.042 vs 3.596), but both values were within a standard deviation of each other for the two sampling times (Fig. 1). It is unlikely, that the longer sampling time is introducing bias into our data. We do observe a significant decrease in diversity when comparing the air samples by lab. The Genesis lab (ISO 4 equivalent) has a lower median number of ASV’s (45.5) than the other labs (62). Median values for Shannon Entropy (3.717 vs. 3.430) and Faith Phylogenetic Diversity (3.796 vs. 3.548) are also lower for Genesis, but those values are with one standard deviation of each other for the different sampling times. This is consistent with previous culture-based results suggesting that the environment in cleanrooms tends to select for a core group of organisms capable of surviving under dry, low nutrient, conditions. The presence of the ASV’s mapping to Cupravidus and Thermus in our sequencing blanks and controls suggests that several of the most common organisms in our samples represent contaminants from the reagents used to perform the DNA extractions and sequencing. Further work is needed to identify these contaminants, remove them from our data and recalculate the diversity statistics. This is a systematic error. Therefore, we do not expect removing the sequencing contaminants to change our conclusions. Longer air sample collection times appear to result in slightly higher diversity and do not bias the results towards “hardy” bacteria like spore-formers. Based on these preliminary results we conclude that sampling at least 3,000 liters of air is sufficient to capture the microbial diversity of cleanrooms, and that air samples can also be collected overnight without negatively impacting diversity. These results allow us to be flexible when designing microbial monitoring plans so that they do not interfere with routine lab activity. References: 1. Regberg, A. B. et al. 49th Lunar and Planetary Science Conference (2018). 2. The United States Pharmacopeial Convention. USP General Chapter <1116> (2013). 3. Regberg, A. B., et al. 54th Lunar and Planetary Science Conference (2023). 4. Regberg, A. B. et al. 53rd Lunar and Planetary Science Conference ( 2022). 5. Davis, R. E.,et al. 50th Lunar and Planetary Science Conference (2019). 6. Qiagen. MagAttract® PowerMicrobiome® DNA/RNA EP Kit Handbook. (2018). 7. Walters, W. et al. mSystems 1, (2015). 8. Callahan, B. J. et al. Nat. Methods 13, 581–583 (2016). 9. Hall, M. & Beiko, R. G. Microbiome Analysis: Methods and Protocols113–129 (Springer, 2018). 10. Philipson, C. et al. Bio-Protoc. 7, e2622 (2017).

A. B. Regberg↗