Search NASA⌕ Search

SEARCH · Search NASA

Results for “current operating point”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Air Breathing Propulsion Controls and Diagnostics Research at NASA Glenn Under NASA Aeronautics Research Mission Programs

This lecture will provide an overview of the aircraft turbine engine control research at NASA (National Aeronautics and Space Administration) Glenn Research Center (GRC). A brief introduction to the engine control problem is first provided with a description of the current state-of-the-art control law structure. A historical aspect of engine control development since the 1940s is then provided with a special emphasis on the contributions of GRC. The traditional engine control problem has been to provide a means to safely transition the engine from one steady-state operating point to another based on the pilot throttle inputs. With the increased emphasis on aircraft safety, enhanced performance and affordability, and the need to reduce the environmental impact of aircraft, there are many new challenges being faced by the designers of aircraft propulsion systems. The Controls and Dynamics Branch (CDB) at GRC is leading and participating in various projects in partnership with other organizations within GRC and across NASA, other government agencies, the U.S. aerospace industry, and academia to develop advanced propulsion controls and diagnostics technologies that will help meet the challenging goals of NASA programs under the Aeronautics Research Mission. The second part of the lecture provides an overview of the various CDB technology development activities in aircraft engine control and diagnostics, both current and some accomplished in the recent past. The motivation for each of the research efforts, the research approach, technical challenges and the key progress to date are summarized. The technologies to be discussed include system level engine control concepts, gas path diagnostics, active component control, and distributed engine control architecture. The lecture will end with a futuristic perspective of how the various current technology developments will lead to an Intelligent and Autonomous Propulsion System requiring none to very minimum pilot interface, interfacing directly with the flight management system to determine its mode of operation, and providing personalized engine control to optimize its performance given the current condition and mission objectives.

Engine Control↗

Dual Inductor Hybrid Converter for Point-of-Load Voltage Regulator Modules

Achieving high-efficiency power conversion with high power density for large conversion ratio is crucially needed yet challenging in point-of-load applications because of increasing demands of loads. This paper presents a new hybrid converter to address this need. The converter uses two interleaved inductors for complete soft charging of flying capacitors to efficiently provide high output currents with no capacitor hard-charge loss. This dual inductor hybrid (DIH) converter features a smaller number of switches and more effective switch utilization than a recently reported Hybrid Dickson converter, yielding substantially less switch losses represented by smaller volt-ampere products and smaller equivalent output resistance. Converter operation principle is analyzed in detail to confirm the feasibility and benefits, and design considerations are provided to identify a practical design process. Experimental results verify the converter's operation principles and advantages with a 300-kHz 20-W prototype achieving 95.02% peak efficiency and 225 W/in 3 power density. Its advantages and performance promise a good candidate point-of-load converter architecture for demanding applications, such as in data centers, telecommunication, and high-performance digital systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

North American SynchroPhasor Initiative – An Update of Progress

In 2007, the U.S. Department of Energy (DOE) and the North American Electric Reliability Corporation (NERC), along with involved electric utility companies and other organizations, formed the North American SynchroPhasor Initiative (NASPI). This effort combines the previous Eastern Interconnection Phasor Project (EIPP) and various activities associated with Wide Area Measurement System (WAMS) research, development, and deployment activities that have been underway in the North American electric power system for a number of years as the primary focal point for continued DOE and NERC support and facilitation. This paper provides an update on this activity, with current status and research work currently underway

CERTS↗

Control of the UV flux of a XeCl dielectric barrier discharge excilamp through its current variation

The efficiency of the electrical power transfer to the gas mixture of a XeCl dielectric barrier discharge (DBD) exciplex lamp is analysed. An equivalent circuit model of the DBD is considered. It is shown that the excilamp power can be controlled by applying current to the lamp. This highly desired property is ensured by means of a specific power supply topology, whose concepts and design are discussed. The experimental prototype of a current-mode converter operating in the pulsed regime at pulse repetition rate of 50 kHz is presented and its capability to control the amount of energy transferred during each current pulse is demonstrated. The capability of this power supply to maintain specific operating conditions for the DBD lamp, with a very stable behaviour (even at a very low current, in the regime of a single discharge channel), is illustrated. The experimental results of a combined use of this converter and a XeCl excilamp are presented. The influence of the supply parameters on the 308-nm XeCl excilamp is analysed. The shape of the UV pulse of the lamp is experimentally shown to be similar to that of the current, which actually flows into the gas mixture. The UV radiation power is demonstrated to be tightly correlated to the current injected into the gas and controlled by the available degrees of freedom offered by the power supply. The measured UV output characteristics and performance of the system are discussed. Time resolved UV imaging of a XeCl DBD excilamp is used to analyse the mechanisms involved in the production of exciplexes at various power supply regimes. It is shown that a pulsed voltage source leads to formation of short high intensity UV peaks, while current pulses lead to formation of sustained discharge filaments. Based on the results of modelling of the above-mentioned operation conditions, the two power supply regimes are compared and analysed from the point of view of the UV power and radiative control.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A 194nW Energy-Performance-Aware loT SoC Employing a 5.2nW 92.6% Peak Efficiency Power Management Unit for System Performance Scaling, Fast DVFS and Energy Minimization

A self-powered IoT system-on-chip (SoC) reduces power to sub-μw and employs multiple power-management techniques to trade-off ultra-low power (ULP), higher performance, smaller energy harvester footprint, and longer operating lifetime. Minimum Energy Point Tracking (MEPT) [1]–[4] keeps an SoC operating at the minimum energy point (MEP) to enhance system lifetime. Previous sample-and-hold MEPT schemes need frequent voltage comparisons and a high-frequency clock that increases power [2]. Current-ratio-based MEPT relies on specialized CMOS technology for body-bias tuning [3]. A switched-capacitor-based MEPT can achieve energy minimization at a targeted performance [4], but it uses a 30MHz clock witμW power consumption and low power efficiency. For ULP IoT applications, SoCs need to have ultra-low quiescent power, high efficiency for energy delivery, performance scaling based on available energy, and energy minimization to increase system lifetime. In this work, we propose an ULP IoT SoC with a triple-mode power management unit (PMU) that integrates energy-performance scaling, event-driven fast DVFS, and MEPT features to improve the system energy efficiency, as shown in Fig. 13.8.1. This work achieves a minimum 194nW power consumption for the SoC and 5.2nW quiescent power for the PMU with a 92.6% peak efficiency and >10 4 dynamic range. The timing waveform in Fig. 13.8.1 (bottom), demonstrates the transition of the three modes including energy aware (EA), performance aware (PA), and MEPT based on event priority and input voltage level which reflects the energy availability. As such, the system energy consumption and performance could be well-balanced based on both the input and output conditions.

self-powered IoT system-on-chip (SoC)↗

Characterization and Remediation of Chlorinated Volatile Organic Contaminants in the Vadose Zone

Contamination of vadose-zone systems by chlorinated solvents is widespread, and poses significant potential risk to human health through impacts on groundwater quality and vapor intrusion. Soil vapor extraction (SVE) is the presumptive remedy for such contamination, and has been used successfully for innumerable sites. However, SVE operations typically exhibit reduced mass-removal effectiveness at some point due to the impact of poorly accessible contaminant mass and associated mass-transfer limitations. Assessment of SVE performance and closure is currently based on characterizing contaminant mass discharge associated with the vadose-zone source, and its impact on groundwater or vapor intrusion. These issues are addressed in this overview, with a focus on summarizing recent advances in our understanding of the transport, characterization, and remediation of chlorinated solvents in the vadose zone. The evolution of contaminant distribution over time and the associated impacts on remediation efficiency will be discussed, as will the potential impact of persistent sources on groundwater quality and vapor intrusion. In addition, alternative methods for site characterization and remediation will be addressed.

Brusseau, Mark L.↗

Enabling Robust Compressor Operation Under Various sCO 2 Conditions at Compressor Inlet

The supercritical carbon dioxide (sCO 2 ) power cycle is one of the most investigated power conversion systems in last decade. The reason for this is its wide range of potential applications from fossil fuels (Natural gas), nuclear (Fusion, Fission), through concentrated solar power, energy storage system and waste heat recovery systems to power-to-x systems. The main advantage of the sCO 2 power cycle is very similar operation conditions, especially for the compressor, for all potential applications. Because of this the potential cost of the system can be reduced. However, the sCO 2 power cycle has still several issue that needs to address before commercial application. The current key issue is design of the primary compressor. The primary compressor is one of the key components in the sCO 2 power cycle; it operates with inlet conditions just above the critical point of CO 2 to maintain high fluid density and reduce power requirements.

14 SOLAR ENERGY↗

Control system development for a 1 MW/e/ solar thermal power plant

The point-focusing distributed receiver power plant considered consists of a number of power modules delivering power to a central collection point. Each power module contains a parabolic dish concentrator with a closed-cycle receiver/turbine/alternator assembly. Currently, a single-module prototype plant is under construction. The major control system tasks required are related to concentrator pointing control, receiver temperature control, and turbine speed control. Attention is given to operational control details, control hardware and software, and aspects of CRT output display.

Daubert, E. R.↗

Loop Heat Pipe Operation with Thermoelectric Converters and Coupling Blocks

This paper presents theoretical and experimental studies on using thermoelectric converters (TECs) and coupling blocks to control the operating temperature of a miniature loop heat pipes (MLHP). The MLHP has two parallel evaporators and two parallel condensers, and each evaporator has its own integral compensation chamber (CC). A TEC is attached to each CC, and connected to the evaporator via a copper thermal strap. The TEC can provide both heating and cooling to the CC, therefore extending the LHP operating temperature over a larger range of the evaporator heat load. A bi-polar power supply is used for the TEC operation. The bipolar power supply automatically changes the direction of the current to the TEC, depending on whether the CC requires heating or cooling, to maintain the CC temperature at the desired set point. The TEC can also enhance the startup success by maintaining a constant CC temperature during the start-up transient. Several aluminum coupling blocks are installed between the vapor line and liquid line. The coupling blocks serve as a heat exchanger which preheats the cold returning liquid so as to reduce the amount of liquid subcooling, and hence the power required to maintain the CC at the desired set point temperature. This paper focuses on the savings of the CC control heater power afforded by the TECs when compared to traditional electric heaters. Tests were conducted by varying the evaporator power, the condenser sink temperature, the CC set point temperature, the number of coupling blocks, and the thermal conductance of the thermal strap. Test results show that the TECs are able to control the CC temperature within k0.5K under all test conditions, and the required TEC heater power is only a fraction of the required electric heater power.

Ku, Jentung↗

Understanding Current Safety Issues for Trajectory Based Operations

Increases in procedural complexity were investigated as a possible contributor to flight path deviations in airline operations. Understanding current operational issues and their causes must be embraced to maintain current safety standards while increasing future functionality. ASRS data and expert narratives were used to discover factors relating to pilot deviations. Our investigation pointed to ATC intervention, automation confusion, procedure design, and mixed equipment as primary issues. Future work will need to include objective data and mitigation strategies.

RNAV STAR↗

Optimizing a Multiple Right-Hand Side Dslash Kernel for Intel Knights Corner

Lattice Quantum Chromo-dynamics (LQCD) stands unique as the only computationally tractable, non-perturbative, and model-independent quantum field theory of the strong nuclear force. LQCD achieves tractability by discretizing our familiar 4-dimensional space-time onto a hypercubic lattice. The core component of the linear solver used in LQCD is the Wilson-Dirac operator whose finite difference component is called the Dslash operator. Dslash is a nearest neighbor stencil operator summing matrix-vector multiplications over lattice points. The arithmetic intensity of a regular Dslash operator acting on a single vector in single precision is between 0.88-2.29 (depending on the tricks employed) making it memory bandwidth bound on most current architectures, including Xeon Phi. Maximizing the performance of Dslash on Xeon Phi requires deliberate exploitation of its architectural features. One key feature of Xeon Phi is its powerful vector processing unit with lengthy vector registers. There is a class of LQCD computations which aims to solve the Dirac equation for the same lattice gauge fields multiple times. In this case one can gain additional reuse of the gauge field, and potentially simplified vectorization, through applying Dslash to several vectors at the same time; often referred to as Multiple Right Hand Side (MRHS) Dslash. Previous work in this area focused on applying this approach to the Highly Improved Staggered operator, and in cases to the multi-Grid algorithm for Wilson clover fermions. Here, we present two approaches to MRHS Dslash: a vector register blocking approach and one using the software package QPhiX with a custom Code Generator for low-level intrinsics. We explore the Knights Corner instruction set, memory hierarchy, and threading capabilities. For standard lattice sizes used in testing, we observed significant speedups, with sustained performance of over 700 GFLOPS (single precision) in one instance. We achieved up to 27% of theoretical peak performance compared to a maximum of 12% obtained by the previous single RHS method in QPhiX.

Joó, Bálint↗

In-situ I-V measurement of a module in a PV array

In one respect, disclosed is an in-situ current-voltage (I-V) measurement device for photovoltaic modules in a photovoltaic array, comprising a variable load, wherein the variable load is configured to be connected in parallel with a module, wherein the module is connected in series with at least one other module in a string, such that the module supplies current simultaneously to the string and to the variable load, and wherein the variable load is controlled by a controller, and wherein the controller is configured to shift an I-V operating point of the module, based at least upon varying the variable load.

Gostein, Michael↗

Dosimetric adaptive IMRT driven by fiducial points

Purpose: Intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy have become standard treatments but are more sensitive to anatomical variations than 3D conformal techniques. To correct for inter- and intrafraction anatomical variations, fast and easy to implement methods are needed. Here, the authors propose a full dosimetric IMRT correction that finds a compromise in-between basic repositioning (the current clinical practice) and full replanning. It simplifies replanning by avoiding a recontouring step and a full dose calculation. It surpasses repositioning by updating the preoptimized fluence and monitor units (MU) using a limited number of fiducial points and a pretreatment (CB)CT. To adapt the fluence the fiducial points were projected in the beam's eye view (BEV). To adapt the MUs, point dose calculation towards the same fiducial points were performed. The proposed method is intrinsically fast and robust, and simple to understand for operators, because of the use of only four fiducial points and the beam data based point dose calculations. Methods: To perform our dosimetric adaptation, two fluence corrections in the BEV are combined with two MU correction steps along the beam's path. (1) A transformation of the fluence map such that it is realigned with the current target geometry. (2) A correction for an unintended scaling of the penumbra margin when the treatment beams scale to the current target size. (3) A correction for the target depth relative to the body contour and (4) a correction for the target distance to the source. The impact of the correction strategy and its individual components was evaluated by simulations on a virtual prostate phantom. This heterogeneous reference phantom was systematically subjected to population based prostate transformations to simulate interfraction variations. Additionally, a patient example illustrated the clinical practice. The correction strategy was evaluated using both dosimetric (CTV mean dose, conformity index) and clinical (tumor control probability, and normal tissue complication probability) measures. Results: Based on the current experiments, the intended target dose and tumor control probability could be assured by the proposed method (TCP ≥ TCP{sub intended}). Additionally, the conformity index error was more than halved compared to the current clinical practice (ΔCI{sub 95%} from 40% to 16%) resulting in improved organ at risk protection. All the individual correction steps had an added value to the full correction. Conclusions: A limited number of fiducial points (no organ contours required) and an in-room (CB)CT are sufficient to perform a full dosimetric correction for IMRT plans. In the presence of interfraction variation, the corrected plans show superior dose distributions compared to our current clinical practice.

60 APPLIED LIFE SCIENCES↗

Model Predictive Control of HVAC Systems: Implementation and Testing at the University of California, Merced

A Model Predictive Control algorithm was developed for the UC Merced campus chilled water plant. Model predictive control (MPC) is an advanced control technology that has proven successful in the chemical process industry and other industries. The main goal of the research was to demonstrate the practical and commercial viability of MPC for optimization of building energy systems. The control algorithms were developed and implemented in MATLAB, allowing for rapid development, performance, and robustness assessment. The UC Merced chilled water plant includes three water-cooled chillers and a two million gallon chilled water storage tank. The tank is charged during the night to minimize on-peak electricity consumption and take advantage of the lower ambient wet bulb temperature. The control algorithms determined the optimal chilled water plant operation including chilled water supply (CHWS) temperature set-point, condenser water supply (CWS) temperature set-point and the charging start and stop times to minimize a cost function that includes energy consumption and peak electrical demand over a 3-day prediction horizon. A detailed model of the chilled water plant and simplified models of the buildings served by the plant were developed using the equation-based modeling language Modelica. Steady state models of the chillers, cooling towers and pumps were developed, based on manufacturers performance data, and calibrated using measured data collected and archived by the control system. A detailed dynamic model of the chilled water storage tank was also developed and calibrated. Simple, semi-empirical models were developed to predict the temperature and flow rate of the chilled water returning to the plant from the buildings. These models were then combined and simplified for use in a model predictive control algorithm that determines the optimal chiller start and stop times and set-points for the condenser water temperature and the chilled water supply temperature. The report describes the development and testing of the algorithm and evaluates the resulting performance, concluding with a discussion of next steps in further research. The experimental results show a small improvement in COP over the baseline policy but it is difficult to draw any strong conclusions about the energy savings potential for MPC with this system only four days of suitable experimental data were obtained once correct operation of the MPC system had been achieved. These data show an improvement in COP of 3.1% {+-} 2.2% relative to a baseline established immediately prior to the period when the MPC was run in its final form. This baseline includes control policy improvements that the plant operators learned by observing the earlier implementations of MPC, including increasing the temperature of the water supplied to the chiller condensers from the cooling towers. The process of data collection and model development, necessary for any MPC project, resulted in the team uncovering various problems with the chilled water system. Although it is difficult to quantify the energy savings resulting from these problems being remedied, they were likely on the same order as the energy savings from the MPC itself. Although the types of problems uncovered and the level of energy savings may differ significantly from other projects, some of the benefits of detecting and diagnosing problems are expected from the use of MPC for any chilled water plant. The degree of chiller loading was found to be a key factor for efficiency. It is more efficient to operate the chillers at or near full load. In order to maximize the chiller load, one would maximize the temperature difference across chillers and the chilled water flow rate through the chillers. Thus, the CHWS set-point and the chilled water flow-rate can be used to limit the chiller loading to prevent chiller surging. Since the flow rate has an upper bound and the CHWS set point has a lower bound, the chiller loading is constrained and often determined by the chilled water return temperature (CHWR). The CHWR temperature is primarily comprised of warm water from the top of the TES tank. The CHWR temperature falls substantially as the thermocline approaches the top of the tank, which reduces the chiller loading. As a result, it has been determined that overcharging the TES tank can be detrimental to the chilled water plant efficiency. The resulting MPC policy differs from the current practice of fully charging the TES tank. A heuristic rule could possible avoid this problem without using predictive control. Similarly, the COP improvements from the change in CWS set-point were largely captured by a static set-point change by the operators. Further research is required to determine how much of the MPC savings could be garnered through simplified rules (based on the MPC study), with and without prediction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and Applications of a Stage Stacking Procedure

The preliminary design of multistage axial compressors in gas turbine engines is typically accomplished with mean-line methods. These methods, which rely on empirical correlations, estimate compressor performance well near the design point, but may become less reliable off-design. For land-based applications of gas turbine engines, off-design performance estimates are becoming increasingly important, as turbine plant operators desire peaking or load-following capabilities and hot-day operability. The current work develops a one-dimensional stage stacking procedure, including a newly defined blockage term, which is used to estimate the off-design performance and operability range of a 13-stage axial compressor used in a power generating gas turbine engine. The new blockage term is defined to give mathematical closure on static pressure, and values of blockage are shown to collapse to curves as a function of stage inlet flow coefficient and corrected shaft speed. In addition to these blockage curves, the stage stacking procedure utilizes stage characteristics of ideal work coefficient and adiabatic efficiency. These curves are constructed using flow information extracted from computational fluid dynamics (CFD) simulations of groups of stages within the compressor. Performance estimates resulting from the stage stacking procedure are shown to match the results of CFD simulations of the entire compressor to within 1.6% in overall total pressure ratio and within 0.3 points in overall adiabatic efficiency. Utility of the stage stacking procedure is demonstrated by estimation of the minimum corrected speed which allows stable operation of the compressor. Further utility of the stage stacking procedure is demonstrated with a bleed sensitivity study, which estimates a bleed schedule to expand the compressors operating range.

Kulkarni, Sameer↗

A New Faraday Screen For Tore Supra ICRH Antenna

In the framework of the Ion Cyclotron (IC) developments held in Cadarache, the design of a new Faraday Screen (FS) was initiated to replace the aging ones mounted on the 3 Tore Supra (TS) antennas. The new conceptual design proposed is steered by conclusive results of electrical simulation stressing the need to suppress the parallel RF currents flowing on the FS frame to reduce the RF sheaths. Two major modifications are implemented on a TS FS to reduce the j{sub ||} circulation: apertures on the top and bottom closure walls of the antenna radiating box, and cantilevered FS bars (that is, bars not connected to the vertical central septum). This single connection point also eases the FS rod thermal expansion, resulting in less mechanical stresses. In addition, the cantilevered bar design avoids eddy current loops which reduces electromagnetically induced stresses during disruptions. If successful with plasma operation, this RF structure provides a promising new option to simplify the ITER IC Faraday screen design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigating the origin of efficiency droop by profiling the temperature across the multi-quantum well of an operating light-emitting diode

Performance degradation resulting from efficiency droop during high-power operation is a critical problem in the development of high-efficiency light-emitting diodes (LEDs). In order to resolve the efficiency droop and increase the external quantum efficiency of LEDs, the droop's origin should be identified first. To experimentally investigate the cause of efficiency droop, we used null-point scanning thermal microscopy to quantitatively profile the temperature distribution on the cross section of the epi-layers of an operating GaN-based vertical LED with nanoscale spatial resolution at four different current densities. The movement of temperature peak towards the p-GaN side as the current density increases suggests that more heat is generated by leakage current than by Auger recombination. We therefore suspect that at higher current densities, current leakage becomes the dominant cause of the droop problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental Investigation of Polymer Induced Fouling of Heater Tubes in the First-ever Polymer Flood Pilot on Alaska North Slope

Polymer flooding has been validated in the lab and by successful applications in other countries, such as Canada and China, to be an effective EOR technique for heavy oil reservoirs. Currently, polymer flooding is being pilot tested for the first time in the Schrader Bluff viscous oil reservoir at Milne Point field on Alaska North Slope (ANS). One of the major concerns of the operator is the impact of polymer on the oil production system after polymer breakthrough, especially the polymer induced fouling issues in the heat exchanger. This study investigates the propensity of polymer fouling on the heater tubes as a function of different variables, with the ultimate goal of determining safe and efficient operating conditions. A unique experimental set-up was indigenously designed and developed to simulate the fouling process on the heating tube. The influence of heating tube skin temperature, tube material, and polymer concentration on fouling tendency was investigated. Under each test condition, the test was run five times with the same tube, and in each run, the freshly prepared synthetic brine and polymer solution were heated from 77°F to 122°F to mimic field operating conditions. The heating time and fouling amount were recorded for each run. The morphology and composition of the deposit samples were analyzed by environmental scanning electron microscopy (ESEM) and X-ray diffraction (XRD), respectively. It has been found that, in general, the presence of polymer in produced fluids would aggravate the fouling issues on both carbon steel and stainless steel surfaces at all tested skin temperatures (165°F, 250 °F and 350°F), but only higher skin temperatures of 250°F and 350°F could cause polymer induced fouling issues on the copper tube surface and the fouling tendency increased with polymer concentration. At the lower skin temperatures of 165°F, no polymer-induced fouling was identified on the copper tube. A critical temperature that is related to the cloud point of the polymer solution was believed to exist, below which polymer induced fouling would not occur and only mineral scale deposited, but above which the polymer would obviously aggravate the fouling issue. The heating efficiency of the tube would be reduced gradually as more fouling material accumulates on its surface. The ESEM results indicate that if polymer precipitated and deposited on the surface, it would bond to the mineral crystals to form a stronger three- dimensional network structure, and that is why the polymer induced fouling was tougher and more difficult to be removed from the tube surface. The XRD analysis results confirm that the presence of polymer in the fluids can enhance the mineral scale propensity. Overall, the study results have provided practical guidance to the field operator for the ongoing polymer flooding pilot test on ANS. This study may also prove to be valuable for other chemical EOR projects around the world.

Alaska North Slope↗