Deployment of POLARBEAR-2b

POLARBEAR-2b (PB-2b) is the second receiver in the Simons Array, a cosmic microwave background (CMB) polarization experiment. The Simons Array uses dichroic polarization sensitive lenslet-coupled sinuous antennas and transition-edge sensor (TES) bolometers made of superconducting films. These bolometers are read out with frequency multiplexing electronics. PB-2b contains ~7500 detectors in two bands at 90 and 150 GHz with arcminute resolution. The polarization of these detectors is modulated by a cryogenic continuously rotating half-wave plate. PB-2b was installed on its telescope in 2022 in the Atacama Desert at an altitude of 5.2 km. This paper will detail initial readout commissioning, test of a new loopgain monitoring method, and focusing the optics. Work is ongoing to commission the remaining ambient temperature readout electronics, measure detector time constants, and observe with the cryogenic half-wave plate spinning.

47 OTHER INSTRUMENTATION↗

Tetris-inspired detector with neural network for radiation mapping

Abstract Radiation mapping has attracted widespread research attention and increased public concerns on environmental monitoring. Regarding materials and their configurations, radiation detectors have been developed to identify the position and strength of the radioactive sources. However, due to the complex mechanisms of radiation-matter interaction and data limitation, high-performance and low-cost radiation mapping is still challenging. Here, we present a radiation mapping framework using Tetris-inspired detector pixels. Applying inter-pixel padding for enhancing contrast between pixels and neural networks trained with Monte Carlo (MC) simulation data, a detector with as few as four pixels can achieve high-resolution directional prediction. A moving detector with Maximum a Posteriori (MAP) further achieved radiation position localization. Field testing with a simple detector has verified the capability of the MAP method for source localization. Our framework offers an avenue for high-quality radiation mapping with simple detector configurations and is anticipated to be deployed for real-world radiation detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The performance of missing transverse momentum reconstruction and its significance with the ATLAS detector using 140 $\hbox {fb}^{-1}$ of $\sqrt{s}=13$ TeV pp collisions

This paper presents the reconstruction of missing transverse momentum ($p_{\text {T}}^{\text {miss}}$ ) in proton–proton collisions, at a center-of-mass energy of 13 TeV. This is a challenging task involving many detector inputs, combining fully calibrated electrons, muons, photons, hadronically decaying $\tau$ -leptons, hadronic jets, and soft activity from remaining tracks. Possible double counting of momentum is avoided by applying a signal ambiguity resolution procedure which rejects detector inputs that have already been used. Several $p_{\text {T}}^{\text {miss}}$ ‘working points’ are defined with varying stringency of selections, the tightest improving the resolution at high pile-up by up to 39% compared to the loosest. The $p_{\text {T}}^{\text {miss}}$ performance is evaluated using data and Monte Carlo simulation, with an emphasis on understanding the impact of pile-up, primarily using events consistent with leptonic Z decays. The studies use $140~\text {fb}^{-1}$ of data, collected by the ATLAS experiment at the Large Hadron Collider between 2015 and 2018. The results demonstrate that $p_{\text {T}}^{\text {miss}}$ reconstruction, and its associated significance, are well understood and reliably modelled by simulation. Finally, the systematic uncertainties on the soft $p_{\text {T}}^{\text {miss}}$ component are calculated. After various improvements the scale and resolution uncertainties are reduced by up to 76% and 51%, respectively, compared to the previous calculation at a lower luminosity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Normal Incidence X-ray Telescope (NIXT) sounding rocket payload

Work on the High Resolution X-ray (HRX) Detector Program is described. In the laboratory and flight programs, multiple copies of a general purpose set of electronics which control the camera, signal processing and data acquisition, were constructed. A typical system consists of a phosphor convertor, image intensifier, a fiber optics coupler, a charge coupled device (CCD) readout, and a set of camera, signal processing and memory electronics. An initial rocket detector prototype camera was tested in flight and performed perfectly. An advanced prototype detector system was incorporated on another rocket flight, in which a high resolution heterojunction vidicon tube was used as the readout device for the H(alpha) telescope. The camera electronics for this tube were built in-house and included in the flight electronics. Performance of this detector system was 100 percent satisfactory. The laboratory X-ray system for operation on the ground is also described.

Golub, Leon↗

Angular resolution of air-shower array-telescopes

A fundamental limit on the angular resolution of air shower array-telescopes is set by the finite number of shower particles coupled with the finite thickness of the particle swarm. Consequently the angular resolution which can be achieved in practice depends in a determinant manner on the size and number of detectors in an array-telescope, as well as on the detector separation and the timing resolution. It is also necessary to examine the meaning of particle density in whatever type of detector is used. Results are given which can be used to predict the angular resolution of a given instrument for showers of various sizes, and to compare different instruments.

Linsley, J.↗

Using quantum noise correlation analysis to measure ion temperature

Quantum noise correlation analysis was tested at the proof-of-concept level as a technique to measure ion temperature in a plasma. If eventually successful, this technique could enable a compact, inexpensive, and robust ion temperature diagnostic suitable for a burning plasma environment. Ion temperature is a key parameter determining the fusion performance of a burning plasma, as the fusion cross-section has a strong dependence on ion temperature. This ion temperature diagnostic would require only a small optical view of the plasma through a port to passively record impurity line emission. The instrumentation would be remote from the reactor behind the neutron and bio-shielding. The technique relies solely on quantum correlations of the photons emitted by a plasma impurity to measure ion temperature; there is no grating dispersion of an emission line-width or pulse-height analysis of photon energy. This measurement innovation was tested with instrumentation consisting of two single-photon detectors with high timing resolution, a time-tagging unit, and simple light collection optics. This instrumentation measures the second-order correlation between the light intensity falling on the two detectors. The next steps beyond the proof-of-concept level will be development of diagnostic designs for application of this technique to high-temperature and burning plasmas. Arrays of single-photon avalanche detectors to multiplex measurements of photon correlation will be required to reduce signal integration time to an acceptable duration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance of the ATLAS forward proton Time-of-Flight detector in Run 2

We present performance studies of the Time-of-Flight (ToF) subdetector of the ATLAS Forward Proton (AFP) detector at the LHC. Efficiencies and resolutions are measured using high-statistics data samples collected at low and moderate pile-up in 2017, the first year when the detectors were installed on both sides of the interaction region. While low efficiencies are observed, of the order of a few percent, the resolutions of the two ToF detectors measured individually are 21 ps and 28 ps, yielding an expected resolution of the longitudinal position of the interaction, z vtx , in the central ATLAS detector of 5.3 ± 0.6 mm. This is in agreement with the observed width of the distribution of the difference between z vtx , measured independently by the central ATLAS tracker and by the ToF detector, of 6.0 ± 2.0 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast and Accurate Pixel Calibration of Tof Neutron Diffractometers with Machine Learning

At a spallation neutron source, neutron pulses of varying energies are generated, and the detection of neutrons by instrument detectors is recorded as time-of-flight from the emission of the neutron pulse to its arrival at specific detector pixels with high time resolution. The flight path of neutrons from the moderator to the sample and then to the detector must be precisely calibrated at the detector-pixel level using standard powders, so the neutron events from all pixels can be time-focused to produce high-resolution diffraction patterns. Modern time-of-flight neutron diffractometers at spallation neutron sources are equipped with two-dimensional detectors with millimeter-scale pixelations. The number of pixels in a diffraction instrument can reach millions, which makes a single-pixel-level calibration process time-consuming or even impossible with conventional refinement or fitting approaches. Here we present a machine-learning-aided calibration process using a train-and-predict approach, in which machine learning models are trained on the relationship between an individual pixel time-of-flight diffraction pattern and its diffraction constant. These models use a portion of the available pixels for training, and a good model then predicts the diffraction constants precisely and rapidly for large sets of pixel diffraction patterns.

detector pixel calibration↗

Expected ${\boldsymbol H \xrightarrow{} {\boldsymbol{\mu^+\mu^-}}} $ measurement precision with ${\boldsymbol { e^{+}e^{-}}{\bf \xrightarrow{}}{ \boldsymbol{Z(q\bar{q})H}}}$ production at the CEPC *

Here, a search for the dimuon decay of the Standard Model Higgs boson is performed using Monte Carlo simulated events to mimic data corresponding to an integrated luminosity of 5.6 ab -1 collected with the Circular Electron-Positron Collider detector in e + e - collisions at $\sqrt{s}$ =240 GeV. This study investigates the e + e - →ZH, Z → $q\bar{q}$, H → μ + μ - process, and the expected significance considering only the statistical uncertainty in the data for a background-only hypothesis for a Higgs boson with a mass of 125 GeV is found to be 6.1 σ, corresponding to a precision of 19%. The systematic impacts from the background Monte Carlo statistical fluctuations are estimated to be negligible. Moreover, the dependence of the measurement accuracy on the muon momentum resolution of the CEPC detector is investigated. It is found that the muon momentum resolution must be better than 204 MeV to discover the H →μμ process at the nominal integrated luminosity. If the resolution is 100% worse than the designed parameter, the integrated luminosity must be greater than 7.2 ab -1 to reach 5σ significance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

JLab eta Factory Experiment in Hall D

The new experiment, JLab Eta Factory (JEF), in the experimental Hall-D at Jefferson Lab will extend the physics potential of the GlueX beyond the main spectroscopy program and study rare decays of eta mesons. Among various physics topics, the experiment will focus on decays of eta mesons to the eta -> pi0 gamma gamma final state. This decay mode provides an important information for higher-order calculations in chiral perturbation theory. The final state is ideal for the search of the leptophobic dark B-boson in the reactions eta -> B gamma, B -> pi0 gamma; and the scaler dark matter mediator S in the channel eta -> pi0 S, S -> gamma gamma. The experiment requires to upgrade the inner part of the forward lead glass calorimeter of the GlueX detector with high-granularity, high-resolution lead tungstate PbWO4 scintillating crystals. The detector will be ready to take data in 2023. I will give an overview of the JEF project.

Somov, Alexander↗

PSEC5 Physical Verification

Ultra-Fast timing detectors, having a time resolution of 10pSec or less, are becoming increasingly important for many scientific disciplines, including High Energy Physics, Nuclear Physics, Medical Imaging and more. When developing ultra-fast detectors such as MCPs, LAPPDs, LGADs, SNSPDs, it is necessary to have access to a readout system that is low power, can support many channels and is cost effective. The PSEC5 chip was an application specific integrated circuit (ASIC) developed by the pioneering group of Prof. Henry Frisch at University of Chicago and micro electronic engineers at Fermi National Accelerator Laboratory. Three boards were designed, two to implement the readout system for an LAPPD and one to only characterize the PSEC1 chip. The main goal of the project shifted to setting up a testing environment to focus on the characterization of the chip. My student and I tested and characterized this ASIC using the third chip-on-board printed circuit board. Results show the successful fabrication and operation of some of the key building blocks and lead to the suggestions on modification for the second iteration of the chip.

Rico Aniles, H. D. [Unlisted]↗

Integrated photonic Galton board and its application for photon counting

The Galton board is a desktop probability machine traditionally used to visualize the principles of statistical physics from classical particles. Here, we demonstrate a photonic Galton board that enables on-chip observation of statistics from single-photon interference. The photonic Galton board consists of a directional coupler matrix terminated by an array of superconducting nanowire detectors to provide spatiotemporal resolution. This design also allows for photon-number-resolving capability, making it suitable for high-speed photon counting. Our results demonstrate the compatibility between single-photon detector array and photonic integrated circuits, paving the way for implementing on-chip large-scale quantum optics experiments and photonic quantum computing.

Qin, Hezheng (ORCID:0009000139348800)↗

Frequency-Selectable Laser Source (FLS) Calibrator for CMB Bandpass Characterization

One of the biggest challenges for Cosmic Microwave Background (CMB) experiments comes from our detector bandpass calibration. Uncertainties in bandpass can severely limit our measurements by limiting foreground removal and spectral fitting, which is particularly important for high-$\ell$ observations like cluster science using the Sunyaev-Zeldovich (SZ) effect. Currently, CMB experiments typically use a Fourier Transform Spectrometer (FTS) to measure the detector bandpasses. However, the resolution of the FTS is dependent on the length of the interferometer arms, leading to a need for increasingly large FTS instruments as CMB experiments require tighter constraints on detector bandpasses. Additionally, systematic effects like shifts in bandpass shape from uneven illumination from the FTS further limit the calibration uncertainties. As a complement to the FTS, we have developed a Frequency-selectable Laser Source (FLS) calibrator, which uses a laser with adjustable frequency housed in a calibrator that allows for varying degrees of laser power attenuation. We present several tests used to characterize the first prototype design of the FLS calibrator, as well as the improvements to the calibrator design currently underway.

Saunders, Lauren [Fermilab]↗

AXAF Detector Backgrounds Produced By Cosmic Ray Protons

One of the science instruments on the Advanced X-ray Astrophysics Facility (AXAF), planned for launch in 1998 into a highly elliptical (10,000 km x 140,000 km) orbit, is a microchannel plate High Resolution Camera (HRC). This detector is designed to provide imaging and spectroscopic observations of x-rays emitted by stellar sources in the 0.1 to 10 keV energy range. Described here are analyses made to determine the expected time-dependent detector background from prompt and delayed (activation) radiation initiated by galactic cosmic-ray (GCR) proton interactions in the spacecraft and payload. Numerical simulations were made using the coupled set of Monte Carlo radiation transport codes, analysis software, and data bases shown. The major codes are HETC for nucleon-meson transport, EGS for simulating electromagnetic cascades, and MORSE for low-energy (less than 15 MeV) neutron transport. The simulation follows the transport history of photons in the energy range from - 100 GeV down to approx. 0.1 keV due to gamma-ray sources from neutral pion decay, high-energy (spallation) collisions, and low-energy neutron inelastic scattering and capture reactions. Also included is radioisotope production and the tracking of gamma-rays, electrons, and positrons from induced radioactivity.

Armstrong, T. W.↗

New measurement of the Fano factor of mercuric iodide

It is pointed out that mercuric iodide (HgI2) shows great promise as a high-resolution X-ray detector for use in X-ray astronomy. Development of mercuric iodide for astronomical work has required investigation of the temperature dependence of the HgI2 crystal parameters such as leakage current, resolution, and mobility of the charge carriers. The first studies in connection with these investigations have led to a new value of the Fano factor of 0.19 + or - 0.03. The best value previously reported was 0.27 measured at room temperature. The new upper limit of 0.19 for the HgI2 Fano factor was determined by cooling the HgI2 crystal and preamp to -20 C. It is concluded that room-temperature energy resolution of HgI2 is not limited by charge generation statistics but rather by collection efficiency.

Ricker, G. R.↗

Measurements of time and spatial resolution of AC-LGADs with different designs

AC-LGAD sensors are prime candidates for fast and precise measurement of charged particles in a variety of applications. In a fine-pitched pixel or strip AC-LGAD sensor, the signal generated by the passage of a particle is not localized in a limited volume in the sensor, but is shared among multiple electrodes. This signal sharing characteristic allows us to improve the spatial resolution of AC-LGAD sensors beyond the capabilities of common silicon trackers. Since the magnitude of the shared signal depends on the distance between the pixels or strips and the point of passage of the particle, signal sharing is strongly influenced by the geometry of the sensor. The electrode pitch and gap size as well as the shape can be fine tuned to maximize the space resolution, while keeping the detector granularity and the number of channels to be read out under control. Prototypes of AC-LGAD sensors produced at the Brookhaven National Laboratory covering a variety of possible geometries have been studied via Transient Current Technique using an infrared laser, and the signal sharing, spatial resolution, and time resolution of the different topologies have been measured. These results have been compared with measurements performed in test-beams with 120 GeV protons at the Fermilab Test Beam Facility. A time resolution of ~30 ps can be achieved using AC-LGAD sensors with a thickness of 50 μm, compatible to that of standard DC-coupled LGADs, while presenting a far superior spatial resolution. Finally, this combination of high precision, fast timing capabilities, and low material budget makes AC-LGADs an ideal choice for a truly 4D detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Vertical gradient freeze growth of detector grade CdZnTeSe single crystals

Here, we report the growth of detector grade Cd 0.9 Zn 0.1 Te 0.97 Se 0.03 (CZTS) single crystals, a recently discovered quaternary semiconductor for room temperature radiation detection, by a vertical gradient freeze (VGF) method. VGF is a comparatively low-temperature growth method and avoids relative motion between the heater and the ampoule containing the precursor materials which minimizes any thermal drift or temperature fluctuations. As a result, CZTS single crystals with superior charge transport properties has been obtained. Growth of detector-grade CZTS single crystals using VGF method has not been reported yet. X-ray spectroscopy based elemental analysis showed that the grown crystals demonstrated the desired stoichiometry required for high resolution radiation detection. Planar detectors fabricated by deposition of gold contacts (~0.07 cm 2 ) demonstrated high bulk resistivity ~10 10 Ω-cm and a very low leakage current density of 2.8 × 10 –8 A/cm 2 at a bias of 100 V when measured at room temperature. The detectors showed excellent radiation response with 100 % charge collection efficiency when exposed to 5486 keV alpha particles. The electron mobility-lifetime (μτ) product was measured to be 3 × 10 –3 cm 2 /V using a single polarity Hecht analysis which is at par with the recently reported values measured in CZTS grown using conventional Bridgman or travelling heater method. The electron mobility has been calculated to be 964 cm 2 V –1 s –1 using a time-of-flight (TOF) method, a substantial improvement over that obtained from conventionally grown CZTS single crystals.

36 MATERIALS SCIENCE↗

SONGS - A high resolution imaging gamma-ray spectrometer for the Space Station

The overall design and the instrumental features of the Space-Station Observer for Nuclear Gamma-ray Spectroscopy (SONGS) instrument are described. SONGS comprises an array of 19 two-segment n-type Ge detectors, which have the capability of determining the interaction site in either the upper or the lower segment or in both segments. The detectors provide high energy resolution of 1 keV at 100 keV and of 2 keV at 1 MeV. The close-packed Ge sensor array provides a natural sensitivity for the measurement of gamma ray polarization in the 100 keV to 1 MeV energy range, making it possible to obtain information on the structure of the magnetosphere of neutron stars and of the accretion disk of black holes.

Nakano, G. H.↗