Search NASA⌕ Search

SEARCH · Search NASA

Results for “duct system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Fuel/Air Premixing System

Fuel and air mixed thoroughly within short distance. In new, simplified system, centrally located fuel injector combined with perforated plate mounted on premixing-duct inlet. Plate causes some fuel spray to move radially outward while mixing with air. Hole patterns in plate designed to enhance even burning and prevent excess fuel from reaching chamber walls. Uniform fuel/air distribution results in improved operation and efficiencies in minimum-length combustor systems.

Ekstedt, E.↗

Continued Verification of MOOSE Structural Mechanics Tools for Modeling Core Bowing Phenomena in Fast Reactors

Under the U.S. Department of Energy Office of Nuclear Energy’s Advanced Modeling and Simulation (NEAMS) Program, an integrated multiphysics approach is being developed to model the core bowing phenomena important to liquid metal-cooled fast reactors. Core bowing is an important passive safety mechanism whereby increased power (which leads to temperature and flux gradients) influences the core to bow into less reactive configurations when the restraint system is properly designed. The phenomenon includes a complex interplay of radiation transport, duct temperature calculations involving fluid flow and heat transfer, and thermo-mechanical responses to the induced temperature and flux gradients. Structural material properties are also important to determining inelastic response to longer term flux gradients which cause irradiation creep and swelling. While core bowing provides a strong negative reactivity feedback when the restraint system is designed properly, it also results in additional forces between assemblies which increase the loads required to extricate them during refueling or control rod movement. Therefore, the restraint system must be designed with these tradeoffs in mind. The first stage of the work, which commenced in FY21 and continues through FY22, assesses thermo-mechanical modeling tools for producing core bowing predictions consistent with conventional tools. The Multiphysics Object Oriented Simulation Environment (MOOSE) Tensor Mechanics and Contact Modules are employed. This status report describes work on additional thermo-mechanical benchmark verification problems with increased complexity from the examples demonstrated in FY21. Several benchmark verification examples were selected from the IAEA verification and validation report. These examples involve clusters of ducts representative of a sector of a hexagonal reactor core which bow into each other and cause contact and load pad elevations, as well as single ducts subjected to irradiation fields undergoing swelling and subsequent bowing. The MOOSE-based results were compared to both IAEA benchmark participants’ results, analytic equations as available, and NUBOW-3D, a beam model code developed by Argonne National Laboratory. In every case, the MOOSE results agreed with other simulations results, providing additional verification basis of the tools for this particular physics application.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

In Hot Water! The Challenges and Barriers of Decarbonizing Water Heating in Multifamily Buildings: Preprint

Domestic hot water heating is responsible for 32% of the total energy consumption in multifamily buildings and offers a significant decarbonization opportunity. An extensive market assessment was conducted to understand and document key technical and economic barriers to electrification of domestic water heating in multifamily buildings throughout the U.S. Through the program, 77 interviews were conducted to understand key market drivers and technical challenges associated with electrification of water heating systems in both retrofit and new construction scenarios. Interviewees encompassed a wide range of stakeholders in the ecosystem surrounding water heating systems, including suppliers, manufacturers, designers, owners, utilities, and developers. This paper documents key interview takeaways, including an extensive list of market barriers, technical challenges, and sought-after technology attributes that can inform pertinent design criteria for electric water heating research, development, and deployment efforts. Among economics and energy efficiency features, interviewees overwhelmingly alluded to space constraints, cold air exhaust, and lack of clear guidance regarding distributed versus centralized design selections as key challenges associated with mass adoption of electric water heating. Owners and developers seek systems with minimal footprint, which maximize rentable space and profits. Moreover, distributed heat pump solutions should balance ducting costs that mitigate cold exhaust entrainment into conditioned zones. Lastly, the market needs clear guidance regarding the selection of distributed versus central electric hot water systems.

challenges of water heating electrification↗

Modifications to Solar Titan-130 Combustion Systems for Efficient, High Turndown Operation

The project team of Southwest Research Institute® (SwRI®), Solar Turbines Incorporated (Solar), the Electric Power Research Institute (EPRI), the University of California, Irvine (UCI), and the Georgia Institute of Technology (Georgia Tech) investigated methods to allow higher efficiency part-load operation of a Solar Titan 130 gas turbine. The objective was to develop a low-emission combustion system capable of sustaining combustion and avoiding lean blowout during high turndown operation, which would allow the gas turbine to operate as efficiently as possible at part load. Currently, electric utility markets are beginning to experience substantial increases in renewable energy generation. Some of these renewable energy sources have highly variable output in an uncontrolled manner. In order to maintain grid stability, there is a need for power plants to ramp up power to the grid rapidly to make up for drops in renewable generation. This is often termed spinning reserve, but the size of this reserve may need to increase as renewable penetration into the electric utility market increases. Small combined heat and power (CHP) power plants provide a promising option for meeting this spinning reserve requirement. In order to operate in spinning reserve while still meeting the heat requirements for the CHP, the gas turbine needs to operate efficiently at very low loads. Efficient, high turndown operations in this engine are limited by the lean flammability limit of the premixed combustion system. This project sought enhance the lean operability range of the Titan 130 combustor. First, the project team participated in a brainstorming activity and ultimately selected two concepts to explore: fuel augmentation with hydrogen (H2) to improve the stability at lean operating conditions and modifications to the fuel nozzle to improve the emissions performance at lean operating conditions. Analytical and laboratory investigations were accomplished by UCI to investigate the efficacy of H2 addition at improving lean blow out (LBO) limits and the resulting emissions. These investigations used a variety of chemical reactor network (CRN) and CFD models, validated against laboratory data, to model the impact of H 2 and inform the experimental efforts accomplished by SwRI and Solar. Ultimately, both the CRN and CFD models yielded generally good agreement with the experimental data below a particular temperature threshold. Atmospheric tests of a full-scale T130 annular combustor were performed at SwRI facilities in San Antonio, Texas, to investigate the use of H 2 addition. For these tests, the T130 combustion system remained largely unchanged; minor modifications were performed to the fuel ducting to allow for the safe use of H 2 . The test ultimately demonstrated that the addition of H 2 to the fuel mixture significantly increased the AFR ratio at which the combustor could operate. This improvement to the LBO limit should allow for less use of compressor bleed and less throttling needed by the inlet guide vanes (IGV). This in turn could result in more efficient operation of the gas turbine at lower load points. The second modification explored in this work was a direct modification to the T130 injector. The project team hypothesized that modifications to the pilot of the T130 injector could provide lower emissions at high turn-down operations. These modifications were manufactured and explored by the team at Solar. High pressure rig tests, originally slated to occur at SwRI, were ultimately accomplished by Solar to maintain overall project budget and mitigate cost growth attributable to supply chain issues and inflation. The pressurized rig tests ultimately showed that the SwRI Project No. 18.24153 - DE-EE0008415 Page 2 Final Technical Report January 24, 2024 modifications did not significantly alter the performance of the combustion system at the high turn-down conditions; both the modified injectors and the baseline configuration exhibited elevated emissions comparted to the full-load operating condition. A final set of studies performed by EPRI investigated the benefit-cost of flexible CHP as well as a grid interconnection study for the California Independent System Operator (CAISO) grid. These studies considered: traditional CHP with no spinning reserve available for on-demand grid support, 50% flexible CHP where 50% of the machine’s capacity is consumed by on-site baseload operations while providing an additional 50% capacity for on-demand grid support, and 70% flexible CHP where 70% of capacity is consumed on-site by baseload operations and 30% is available for on-demand grid support. In all cases, the analyses showed a benefit-to-cost ratio greater than unity implying a positive net present value for all configurations. However, the traditional CHP showed the most economic benefit. These results are sensitive to several factors, many of which are not fully known and may vary over time. Thus site owners must be convinced that taking up the increased costs and risks from flexible CHP would be worth implementing. As the grid in California and across the country transition to incorporate larger renewable energy generation, flexible CHP can provide much needed operating reserves and dispatchability. Alternative fuel options, such as hydrogen blending and biofuels, may also lower carbon intensities of CHP. Flexible CHP should be examined in the evolving market to understand innovative business models, changes market rules and services, and new technologies.

20 FOSSIL-FUELED POWER PLANTS↗

Minimizing Auxiliary Heat Use for Cold Climate Operation of Air Source Heat Pumps: Preprint

This paper investigates the auxiliary heat use for air-source heat pumps (ASHPs) operating in cold climates. Twelve variable-capacity, central ducted ASHPs installed in single-family homes in cold climate regions (eleven in the northwest United States and one in a Denver suburb) were monitored for an entire winter season to collect data at cold temperatures. The methodology employed airside and power measurements that were taken every five seconds, to calculate the heat pump’s capacity, coefficient of performance (COP), and auxiliary heat energy consumption. This paper provides insights into the practical implications of auxiliary heat utilization in centrally ducted ASHPs and suggests opportunities to mitigate the usage of auxiliary heat, improving overall system efficiency during cold climate operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spinoff 2010

Topics covered include: Burnishing Techniques Strengthen Hip Implants; Signal Processing Methods Monitor Cranial Pressure; Ultraviolet-Blocking Lenses Protect, Enhance Vision; Hyperspectral Systems Increase Imaging Capabilities; Programs Model the Future of Air Traffic Management; Tail Rotor Airfoils Stabilize Helicopters, Reduce Noise; Personal Aircraft Point to the Future of Transportation; Ducted Fan Designs Lead to Potential New Vehicles; Winglets Save Billions of Dollars in Fuel Costs; Sensor Systems Collect Critical Aerodynamics Data; Coatings Extend Life of Engines and Infrastructure; Radiometers Optimize Local Weather Prediction; Energy-Efficient Systems Eliminate Icing Danger for UAVs; Rocket-Powered Parachutes Rescue Entire Planes; Technologies Advance UAVs for Science, Military; Inflatable Antennas Support Emergency Communication; Smart Sensors Assess Structural Health; Hand-Held Devices Detect Explosives and Chemical Agents; Terahertz Tools Advance Imaging for Security, Industry; LED Systems Target Plant Growth; Aerogels Insulate Against Extreme Temperatures; Image Sensors Enhance Camera Technologies; Lightweight Material Patches Allow for Quick Repairs; Nanomaterials Transform Hairstyling Tools; Do-It-Yourself Additives Recharge Auto Air Conditioning; Systems Analyze Water Quality in Real Time; Compact Radiometers Expand Climate Knowledge; Energy Servers Deliver Clean, Affordable Power; Solutions Remediate Contaminated Groundwater; Bacteria Provide Cleanup of Oil Spills, Wastewater; Reflective Coatings Protect People and Animals; Innovative Techniques Simplify Vibration Analysis; Modeling Tools Predict Flow in Fluid Dynamics; Verification Tools Secure Online Shopping, Banking; Toolsets Maintain Health of Complex Systems; Framework Resources Multiply Computing Power; Tools Automate Spacecraft Testing, Operation; GPS Software Packages Deliver Positioning Solutions; Solid-State Recorders Enhance Scientific Data Collection; Computer Models Simulate Fine Particle Dispersion; Composite Sandwich Technologies Lighten Components; Cameras Reveal Elements in the Short Wave Infrared; Deformable Mirrors Correct Optical Distortions; Stitching Techniques Advance Optics Manufacturing; Compact, Robust Chips Integrate Optical Functions; Fuel Cell Stations Automate Processes, Catalyst Testing; Onboard Systems Record Unique Videos of Space Missions; Space Research Results Purify Semiconductor Materials; and Toolkits Control Motion of Complex Robotics.

Source record↗

Prediction of laminar and turbulent primary and secondary flows in strongly curved ducts

The analysis is based on a primary secondary velocity decomposition in a given coordinate system, and leads to approximate governing equations which correct an a priori inviscid solution for viscous effects, secondary flows, total pressure distortion, heat transfer, and internal flow blockage and losses. Solution of the correction equations is accomplished as an initial value problem in space using an implicit forward marching technique. The overall solution procedure requires significantly less computational effort than Navier-Stokes algorithms. The solution procedure is effective even with the extreme local mesh resolution which is necessary to solve near wall sublayer regions in turbulent flow calculations. Computed solutions for both laminar and turbulent flow compared very favorably with available analytical and experimental results. The overall method appears very promising as an economical procedure for making detailed predictions of viscous primary and secondary flows in highly curved passages.

Kreskovsky, J. P.↗

A new concept for exhaust diffusers of altitude test cells

A new exhaust diffuser concept for jet engine altitude test cells which greatly reduces operating power and cost requirements for exhausters is discussed. The concept utilizes the capture duct as an efficient diffuser only, while evacuating the secondary air via a separate path using an auxiliary suction system. Implementation of the concept would reduce the peak exhauster power requirement during a TF-30 altitude test by 48 percent and the overall exhaust power cost of the test program by 41 percent. The design accommodates various engine sizes and can achieve optimum pressure recovery performance during both A/B and IRP modes of engine operation. The pressure recovery performance of the proposed exhaust diffusers does not deteriorate with increasing cooling air fraction. The disadvantages of the proposed scheme are: increased mechanical complexity of the extended variable geometry diffuser duct and the need for an auxiliary suction system for evacuating cell-cooling air.

Parikh, P. G.↗

Internally supported flexible duct joint

An internally supported, flexible duct joint for use in conducting fluids under relatively high pressures in systems where relatively large deflection angles must be accommodated is presented. The joint includes a flexible tubular bellows and an elongated base disposed within the bellows. The base is connected through radiating struts to the bellows near mid-portion and to each of the opposite end portions of the bellows through a pivotal connecting body. A motion-controlling linkage is provided for linking the connecting bodies, whereby angular displacement of the joint is controlled and uniformity in the instantaneous bend radius of the duct is achieved as deflection is imposed.

Kuhn, R. F., Jr.↗

Computations of Viscous Flows in Complex Geometries Using Multiblock Grid Systems

Generating high quality, structured, continuous, body-fitted grid systems (multiblock grid systems) for complicated geometries has long been a most labor-intensive and frustrating part of simulating flows in complicated geometries. Recently, new methodologies and software have emerged that greatly reduce the human effort required to generate high quality multiblock grid systems for complicated geometries. These methods and software require minimal input form the user-typically, only information about the topology of the block structure and number of grid points. This paper demonstrates the use of the new breed of multiblock grid systems in simulations of internal flows in complicated geometries. The geometry used in this study is a duct with a sudden expansion, a partition, and an array of cylindrical pins. This geometry has many of the features typical of internal coolant passages in turbine blades. The grid system used in this study was generated using a commercially available grid generator. The simulations were done using a recently developed flow solver, TRAF3D.MB, that was specially designed to use multiblock grid systems.

Steinthorsson, Erlendur↗

Minimizing Auxiliary Heat Use for Cold Climate Operation of Air-Source Heat Pumps

This paper investigates the auxiliary heat use for air-source heat pumps (ASHPs) operating in cold climate conditions. Twelve variable-capacity, central ducted ASHPs installed in single-family homes in cold climate regions (eleven in northwest United States and one in Denver suburb) were monitored for an entire winter season to collect data at cold temperatures. The methodology employed airside and power measurements that were taken every five-seconds, to calculate heat pump's capacity, coefficient of performance (COP), and auxiliary heat energy consumption. This paper provides valuable insights into the practical implications of auxiliary heat utilization in centrally ducted ASHPs and suggests opportunities to mitigate the usage of auxiliary heat, improving the overall system efficiency during cold climate operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Three Dimensional Compressible Turbulent Flow Computations for a Diffusing S-Duct With/Without Vortex Generators

Numerical investigations on a diffusing S-duct with/without vortex generators and a straight duct with vortex generators are presented. The investigation consists of solving the full three-dimensional unsteady compressible mass averaged Navier-Stokes equations. An implicit finite volume lower-upper time marching code (RPLUS3D) has been employed and modified. A three-dimensional Baldwin-Lomax turbulence model has been modified in conjunction with the flow physics. A model for the analysis of vortex generators in a fully viscous subsonic internal flow is evaluated. A vortical structure for modeling the shed vortex is used as a source term in the computation domain. The injected vortex paths in the straight duct are compared with the analysis by two kinds of prediction models. The flow structure by the vortex generators are investigated along the duct. Computed results of the flow in a circular diffusing S-duct provide an understanding of the flow structure within a typical engine inlet system. These are compared with the experimental wall static-pressure, static- and total-pressure field, and secondary velocity profiles. Additionally, boundary layer thickness, skin friction values, and velocity profiles in wall coordinates are presented. In order to investigate the effect of vortex generators, various vortex strengths are examined in this study. The total-pressure recovery and distortion coefficients are obtained at the exit of the S-duct. The numerical results clearly depict the interaction between the low velocity flow by the flow separation and the injected vortices.

Cho, Soo-Yong↗

Active Control of Fan Noise: Feasibility Study: Flyover System Noise Studies - Volume 4

An extension of a prior study has been completed to examine the potential reduction of aircraft flyover noise by the method of active noise control (ANC). It is assumed that the ANC system will be designed such that it cancels discrete tones radiating from the engine fan inlet or fan exhaust duct, at least to the extent that they no longer protrude above the surrounding broadband noise levels. Thus, without considering the engineering details of the ANC system design, tone levels am arbitrarily removed from the engine component noise spectrum and the flyover noise EPNL levels are compared with and without the presence of tones. The study was conducted for a range of engine cycles, corresponding to fan pressure ratios of 1.3, 1.45, 1.6, and 1.75. This report is an extension of an effort reported previously. The major conclusions drawn from the prior study, which was restricted to fan pressure ratios of 1.45 and 1.75, are that, for a fan pressure ratio of 1.75, ANC of tones gives about the same suppression as acoustic treatment without ANC. For a fan pressure ratio of 1.45, ANC appears to offer less effectiveness from passive treatment. In the present study, the other two fan pressure ratios are included in a more detailed examination of the benefits of the ANC suppression levels. The key results of this extended study are the following observations: (1) The maximum overall benefit obtained from suppression of BPF alone was 2.5 EPNdB at high fan speeds. The suppression benefit increases with increase in fan pressure ratio (FPR), (2) The maximum overall benefit obtained from suppression of the first three harmonics was 3 EPNdB at high speeds. Suppression benefit increases with increase in FPR, (3) At low FPR, only about 1.0 EPNdB maximum reduction was obtained. Suppression is primarily from reduction of BPF at high FPR values and from the combination of tones at low FPR, (4) The benefit from ANC is about the same as the benefit from passive treatment at fan pressure ratios of 1.75 and 1.60. At the two lower fan pressure ratios, the effectivness of treatment is much greater than that of ANC, and (5) No significant difference in ANC suppression behavior was found from the QCSEE engine database analysis compared to that of the E3 engine database, for the FPR = 1.3 engine cycle. The effects of ANC on EPNL noise reduction are difficult to generalize. It was found that the reduction obtained in any particular case depended upon the frequency of the tones and their shift with rpm, the amount of ANC suppression received by each tone (which depended on its protrusion from the background), and the NOY-value of the tone relative to the NOY-value of other tones and the peak broadband levels, because PNL is determined from the sum of the NOY-values.

Kraft, R. E.↗

High contribution of canopy to oleoresin accumulation in loblolly pine trees

The shoot system of all loblolly pine (Pinus taeda L.) contains abundant resin ducts, and the oleoresins contained within them have demonstrated roles in constitutive defenses. This study is providing a quantitative assessment of oleoresin biosynthesis and accumulation in resin ducts. Morphometric analyses of representative tissue sections indicate that the fractional volume of resin ducts is particularly high in the cortex of young stems and their needles, representing a major portion of total pine resins from primary growth of the canopy. We demonstrate that it is possible to extrapolate oleoresin formation from the microscopic scale (tissues sections) to the macroscale (entire trees), which has implications for assessing resins as renewable feedstocks for bioproducts.

Srividya, Narayanan↗

Ejector nozzle with massive blowing

Jet-flap, wing-blowing system for use in short takeoff and landing aircraft is described. System depends on ejector nozzle with large blowing capacity to direct ducted air against deflected flap. Operation of equipment during takeoff and cruise conditions is discussed. Diagrams of equipment are provided.

True, H. C.↗

Determination of two-stroke engine exhaust noise by the method of characteristics

A computational technique was developed for the method of characteristics solution of a one-dimensional flow in a duct as applied to the wave action in an engine exhaust system. By using the method, it was possible to compute the unsteady flow in both straight pipe and tuned expansion chamber exhaust systems as matched to the flow from the cylinder of a small two-stroke engine. The radiated exhaust noise was then determined by assuming monopole radiation from the tailpipe outlet. Very good agreement with experiment on an operation engine was achieved in the calculation of both the third octave radiated noise and the associated pressure cycles at several locations in the different exhaust systems. Of particular interest is the significance of nonlinear behavior which results in wave steepening and shock wave formation. The method computes the precise paths on the x-t plane of a finite number of C(sub +), C(sub -) and P characteristics, thereby obtaining high accuracy in determining the tailpipe outlet velocity and the radiated noise.

Jones, A. D.↗

Waterproof Raised Floor Makes Utility Lines Accessible

Floor for laboratories, hospitals and factories waterproof yet allows access to subfloor utilities. Elevated access floor system designed for installations with multitude of diverse utility systems routed under and up through floor and requirement of separation of potentially conflicting utility services. Floor covered by continuous sheet of heat resealable vinyl. Floor system cut open when changes are made in utility lines and ducts. After modifications, floor covering resealed to protect subfloor utilities from spills and leaks.

Cohen, M. M.↗