Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

The FIREBIRD-II CubeSat Mission (Focused Investigations of Relativistic Electron Burst Intensity, Range, and Dynamics)

FIREBIRD-II is a National Science Foundation funded CubeSat mission designed to study the scale size and energy spectrum of relativistic electron microbursts. The mission consists of two identical 1.5 U CubeSats in a low earth polar orbit, each with two solid state detectors that differ only in the size of their geometric factors and fields of view. Having two spacecraft in close orbit allows the scale size of microbursts to be investigated through the intra-spacecraft separation when microbursts are observed simultaneously on each unit. Each detector returns high cadence (10 s of ms) measurements of the electron population from 200 keV to >1 MeV across six energy channels. The energy channels were selected to fill a gap in the observations of the Heavy Ion Large Telescope instrument on the Solar, Anomalous, and Magnetospheric Particle Explorer. FIREBIRD-II has been in orbit for 5 years and continues to return high quality data. After the first month in orbit, the spacecraft had separated beyond the expected scale size of microbursts, so the focus has shifted toward conjunctions with other magnetospheric missions. FIREBIRD-II has addressed all of its primary science objectives, and its long lifetime and focus on conjunctions has enabled additional science beyond the scope of the original mission. This paper presents a brief history of the FIREBIRD mission’s science goals, followed by a description of the instrument and spacecraft. The data products are then discussed along with some caveats necessary for proper use of the data.

47 OTHER INSTRUMENTATION↗

Oscillator with wide dynamic tuning range

Two or more tandem amplifier stages, one of which is tuned, added to a circuit permit tuning an oscillator over frequency range of six decades. Oscillator operates in distributed mode for increased frequency stability. Within practical limitations, stability increases by increasing number of tuned stages.

Rippy, R. R.↗

Handbook for the calculation of approximate data for spaceborne sensors

In allocating the RF spectrum for the transmission of sensed data from space to earth, the characteristics of the data produced by each sensor are discussed. For example, data may be in the form of a continually varying voltage (analog) or may be a series of discrete pulses (digital). For the analog signal, its important characteristics to the spectrum allocator are its highest frequency component (bandwidth) and its range from minimum values (dynamic range or signal-to-noise ratio). For the digital signal, the characteristic of interest is the bit rate.

Source record↗

Determining CDOM Absorption Spectra in Diverse Aquatic Environments Using a Multiple Pathlength, Liquid Core Waveguide System

We evaluated the accuracy, sensitivity and precision of a multiple pathlength, liquid core waveguide (MPLCW) system for measuring colored dissolved organic matter (CDOM) absorption in the UV-visible spectral range (370-700 nm). The MPLCW has four optical paths (2.0, 9.8, 49.3, and 204 cm) coupled to a single Teflon AF sample cell. Water samples were obtained from inland, coastal and ocean waters ranging in salinity from 0 to 36 PSU. Reference solutions for the MPLCW were made having a refractive index of the sample. CDOM absorption coefficients, aCDOM, and the slope of the log-linearized absorption spectra, S, were compared with values obtained using a dual-beam spectrophotometer. Absorption of phenol red secondary standards measured by the MPLCW at 558 nm were highly correlated with spectrophotometer values and showed a linear response across all four pathlengths. Values of aCDOM measured using the MPLCW were virtually identical to spectrophotometer values over a wide range of concentrations. The dynamic range of aCDOM for MPLCW measurements was 0.002 - 231.5 m-1. At low CDOM concentrations spectrophotometric aCDOM were slightly greater than MPLCW values and showed larger fluctuations at longer wavelengths due to limitations in instrument precision. In contrast, MPLCW spectra followed an exponential to 600 nm for all samples.

Miller, Richard L.↗

Determining CDOM Absorption Spectra in Diverse Coastal Environments Using a Multiple Pathlength, Liquid Core Waveguide System. Measuring the Absorption of CDOM in the Field Using a Multiple Pathlength Liquid Waveguide System

We evaluated the accuracy, sensitivity and precision of a multiple pathlength, liquid core waveguide (MPLCW) system for measuring colored dissolved organic matter (CDOM) absorption in the UV-visible spectral range (370-700 nm). The MPLCW has four optical paths (2.0, 9.8, 49.3, and 204 cm) coupled to a single Teflon AF sample cell. Water samples were obtained from inland, coastal and ocean waters ranging in salinity from 0 to 36 PSU. Reference solutions for the MPLCW were made having a refractive index of the sample. CDOM absorption coefficients, a(sub CDOM), and the slope of the log-linearized absorption spectra, S, were compared with values obtained using a dual-beam spectrophotometer. Absorption of phenol red secondary standards measured by the MPLCW at 558 nm were highly correlated with spectrophotometer values (r > 0.99) and showed a linear response across all four pathlengths. Values of a(sub CDOM) measured using the MPLCW were virtually identical to spectrophotometer values over a wide range of concentrations. The dynamic range of a(sub CDOM) for MPLCW measurements was 0.002 - 231.5/m. At low CDOM concentrations (a(sub 370) < 0.1/m) spectrophotometric a(sub CDOM) were slightly greater than MPLCW values and showed larger fluctuations at longer wavelengths due to limitations in instrument precision. In contrast, MPLCW spectra followed an exponential to 600 nm for all samples. The maximum deviation in replicate MPLCW spectra was less than 0.001 absorbance units. The portability, sampling, and optical characteristics of a MPLCW system provide significant enhancements for routine CDOM absorption measurements in a broad range of natural waters.

Miller, Richard L.↗

Chemoattractant receptors activate, recruit and capture G proteins for wide range chemotaxis

Highlights: • Chemotactic GPCR forms an unconventional complex with the activated Gα. • Receptors activate, recruit and capture G proteins at different cAMP concentrations. • Capture of Gα can contribute to gradient sensing at high cAMP concentrations. The wide range sensing of extracellular signals is a common feature of various sensory cells. Eukaryotic chemotactic cells driven by GPCRs and their cognate G proteins are one example. This system endows the cells directional motility towards their destination over long distances. There are several mechanisms to achieve the long dynamic range, including negative regulation of the receptors upon ligand interaction and spatial regulation of G proteins, as we found recently. However, these mechanisms are insufficient to explain the 10{sup 5}-fold range of chemotaxis seen in Dictyostelium. Here, we reveal that the receptor-mediated activation, recruitment, and capturing of G proteins mediate chemotactic signaling at the lower, middle and higher concentration ranges, respectively. These multiple mechanisms of G protein dynamics can successfully cover distinct ranges of ligand concentrations, resulting in seamless and broad chemotaxis. Furthermore, single-molecule imaging analysis showed that the activated Gα subunit forms an unconventional complex with the agonist-bound receptor. This complex formation of GPCR-Gα increased the membrane-binding time of individual Gα molecules and therefore resulted in the local accumulation of Gα. Our findings provide an additional chemotactic dynamic range mechanism in which multiple G protein dynamics positively contribute to the production of gradient information.

60 APPLIED LIFE SCIENCES↗

An Overview of NASA Space Cryocooler Programs--2006

Mechanical cryocoolers represent a significant enabling technology for NASA's Earth and Space Science Enterprises. Many of NASA's space instruments require cryogenic refrigeration to improve dynamic range, extend wavelength coverage, or enable the use of advanced detectors to observe a wide range of phenomena--from crop dynamics to stellar birth. Reflecting the relative maturity of the technology at these temperatures, the largest utilization of coolers over the last fifteen years has been for instruments operating at medium to high cryogenic temperatures (55 to 150K). For the future, important new developments are focusing on the lower temperature range, from 6 to 20 K, in support of studies of the origin of the Universe and the search for planets around distant stars. NASA's development of a 20K cryocooler for the European Planck spacecraft and a 6 K cryocooler for the MIRI instrument on the James Webb Space Telescope (JWST) are examples of the thrust to provide low-temperature cooling for this class of future missions.

cryogenics↗

Fourier Spectroscopy as a Method of Investigation of Photoelectric Properties of Organic Systems

A new method of investigation of photoelectric properties of layered thin-film structures based on broadband Fourier spectroscopy exhibiting a harmonically modulated optical delay is proposed. In contrast to traditional approaches to study photoelectric properties, which are based on application of dispersive spectral devices, the proposed method allows not only simultaneously covering the ultraviolet, visible, and infrared spectral ranges, while demonstrating a wide dynamic range and high spectral resolution, but also easily varying low-frequency modulation of the action of light. The capabilities of the method are demonstrated using a polycrystalline organic heterostructure as an example. Its spectral sensitivity, speed, and specific detectivity are measured. A model and an equivalent electric circuit are proposed for explanation of the results of the measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

COBE Final Report: Dirbe Celestial Calibration

We report the results of a comparative study of the COsmic Background Explorer/Diffuse InfraRed Background Experiment (COBE/DIRBE) photometric calibration over about 100 selected stellar and non-stellar calibration objects across a wide range of the DIRBE instrument dynamic range, wavelength coverage, and source temperature. A statistical comparison of the DIRBE-reported flux to the accepted values from the literature (as summarized in the CIO) provides an independent verification of the DIRBE point source calibration.

Burdick, Shawn V.↗

NASA Space Cryocooler Programs: A 2003 Overview

Mechanical cryocoolers represent a significant enabling technology for NASA's Earth and Space Science missions. An overview is presented of ongoing cryocooler activities within NASA in support of current flight projects, near-term flight instruments, and long-term technology development. NASA programs in Earth and space science observe a wide range of phenomena, from crop dynamics to stellar birth. Many of the instruments require cryogenic refrigeration to improve dynamic range, extend wavelength coverage, and enable the use of advanced detectors. Although, the largest utilization of coolers over the last decade has been for instruments operating at medium to high cryogenic temperatures (55 to 150 K), reflecting the relative maturity of the technology at these temperatures, important new developments are now focusing at the lower temperature range from 4 to 20 K in support of studies of the origin of the universe and the search for planets around distant stars. NASA's development of a 20K cryocooler for the European Planck spacecraft and its new Advanced Cryocooler Technology Development Program (ACTDP) for 6-18 K coolers are examples of the thrust to provide low temperature cooling for this class of missions.

Ross, R. G., Jr.↗

Extraction of Doppler Observables from Open-Loop Recordings for the Juno Radio Science Investigation

The goal of the Juno Gravity Science investigation is to estimate the gravitational field of Jupiter by measurement of the spacecraft velocity during periods of closest approach. Velocity is measured by the Doppler shift of dual X- and Ka-band radio links between the Juno spacecraft, in orbit around Jupiter, and the DSS-25 antenna of the Deep Space Network (DSN). During times of closest-approach, Juno experiences large dynamic ranges caused by the orbital dynamics and spin signatures caused by the spin-stabilized spacecraft that are detectable by the receivers at DSS-25. Open-loop recordings of received voltages are processed to compute Doppler observables utilized in the estimation of the gravity field. Presented is a method to process open-loop data collected by the DSN to compensate for the spin signature of the spacecraft, removal of artifacts from Doppler observables caused by the high dynamic environment, and improve performance of the digital phase-locked loop utilized in the data processing.

Buccino, Dustin R.↗

Thermal and nonthermal X-ray bursts observed from OSO-7

The UCSD solar X-ray experiment on the OSO-7 observes X-rays in the 2 to 15 keV range with a proportional counter and in the 10.6 to 300 keV range with a scintillation counter. The dynamic range and instrument parameters are chosen to separate X-ray emission due to a hot thermal plasma from that due to nonthermal electron populations for a large number of X-ray events associated with small flares. Many different morphological classes have been observed in the 200 or so principal events observed between October 1971 and June 1972. For events which have both a thermal and nonthermal component, we can perform an analysis which shows that in not all events is it possible for the nonthermal electrons to energize the thermal plasma. We observe many events which have no nonthermal component, at least one event which was purely power law on initiation, and several events which had a long, slow decay of the hard X-rays.

Peterson, L. E.↗

The Rome-GSFC magnetic field experiment for Helios A and B /E 3/

The Rome-GSFC magnetic field experiment utilizes a triaxial fluxgate (saturable inductor) magnetometer. The sensor unit is mounted on the end of a boom approximately four meters from the spacecraft spin axis. The three analog outputs of the magnetometer are converted into three 9 bit digital words. The experiment utilizes an automatic inflight range switch to select the optimum dynamic range out of 4 ranges. A nonmagnetic thermally oscillating actuator is used to reorient the sensor unit by 90 deg to determine all three axes zero levels. The accuracy should be approximately plus or minus 0.1 gamma. The vector measurements are made at equal intervals in time ranging from 16 per second down to 1 per second depending on the telemetry bit rate.

Scearce, C.↗