Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrode array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Epidermal Impedance Sensing Sheets for Precision Hydration Assessment and Spatial Mapping

This paper presents a class of hydration monitor that uses ultrathin, stretchable sheets with arrays of embedded impedance sensors for precise measurement and spatially multiplexed mapping. The devices contain miniaturized capacitive electrodes arranged in a matrix format, capable of integration with skin in a conformal, intimate manner due to the overall skin-like physical properties. These “epidermal” systems noninvasively quantify regional variations in skin hydration, at uniform or variable skin depths. Experimental results demonstrate that the devices possess excellent uniformity, with favorable precision and accuracy. Theoretical models capture the underlying physics of the measurement and enable quantitative interpretation of the experimental results. Furthermore, these devices are appealing for applications ranging from skin care and dermatology, to cosmetology and health/wellness monitoring, with the additional potential for combined use with other classes of sensors for comprehensive, quantitative physiological assessment via the skin.

42 ENGINEERING↗

Inversion of downhole electrical measurements for proppant mapping using very fast simulated annealing

Proppant mapping is critical for optimizing fracture treatment design and improving wells’ productivity. An electrode-based resistivity tool concept was developed earlier for proppant mapping in cased-hole wells. An array of insulating gaps is installed and cemented in place as a permanent part of the casing string. The electrical measurements are performed by imposing a voltage across each insulating gap, one at a time, before and after hydraulic fracture operations. The voltages across other insulating gaps near the transmitter gap are recorded. The method relies on direct excitation of the casing, which is expected to overcome the severe limitations of induction tools in cased-hole wells. A forward model based on a finite volume method has been developed to simulate the tool’s response to one or multiple fractures. To enable the implementation of such a practical system in multistage fractured horizontal wells, a fast and robust inversion approach is required. To that end, we have developed a divide-and-conquer approach based on a global optimization algorithm very fast simulated annealing (VFSA). Specifically, the original inverse problem is divided into subproblems and each subproblem can be solved separately using VFSA. The results indicate that our approach can invert the data and output widths and radii of multiple fractures without requiring a large number of forward simulations. The robustness of the inverse solver is also tested by adding Gaussian noise to the synthetic data. We tested example cases that demonstrate that when up to 5% noise is introduced, VFSA still provides very accurate inversion results with moderate uncertainties. Inversion results with some more realistic conditions, e.g., tilted fractures, complex fractures, and so on, are also presented.

Geochemistry & Geophysics↗

Optical efficiency of far-infrared photoconductors

The present optimization of the geometry of far-IR photoconductive detectors with diffraction-limited throughput, on the basis of experimental and theoretical results, gives attention to the internal optical path relative to measured absorption length, photoconductive gain, uniformity of illumination, cosmic ray cross section, and design compatibility with the requirements of one- and two-dimensional arrays. It is demonstrated that a rod-shaped, square cross section detector geometry, having lateral face electrodes and a beveled backface with which to trap the radiation by total internal reflection, exhibits responsivity commensurate with that of the best available detectors in integrating cavities.

Wang, J.-Q.↗

Measuring the Chemical Potential of the Martian Regolith to Generate and Sustain Life

A critical component for identifying chemical biosignatures is the ability to assess in-situ the potential of an aqueous geochemical environment to generate and sustain life. On Mars or other solar bodies, in-situ chemical characterization could provide evidence as to whether the chemical composition of the regolith or evaporites in suspected ancient water bodies have been biologically influenced or possess the chemical parameters within which life may have existed, or may still exist. A variety of analytical techniques have been proposed for use in detecting and identify signatures of past or present life. These techniques fall into two groups; visual observation with instruments such as cameras or optical/atomic-force microscopes; or elemental chemical analysis with such instruments as X-ray fluorescence (XRF) and diffraction (XRD), a-proton backscatter (APX), y-ray, Mossbauer, Raman, IR, UV/VIS spectroscopies, gas chromatography (GC), or mass spectrometry (MS). Direct observation of an identifiable lifeform by the first set of instruments in a single sample is highly unlikely, especially for extinct organisms or on the surface. The later instruments can provide vital data as to the elemental mineralogy and geological history of the planet, but are highly inadequate for understanding the chemistry of the planet in terms of indigenous life or interactions with human explorers. Techniques such as XRD, XRF, and APX, provide elemental composition at high limits of detection. Some of this data can be extrapolated or interpolated to provide chemical parameters such as oxidation state or composition. Gas chromatography (GC) without standards and non-specific detectors, has little chance of identifying a mixture of unknown components. Combined with GC or by itself, mass spectrometry (MS) can provide identification of compounds, but in both cases the sample must be appropriately prepared for accurate and reliable analysis. Life as we know it, and probably identify it as such, requires an aqueous environment. Deciphering die chemical speciation of this aqueous environment is the key to recognizing therein the biosignatures of any extinct or present life forms. Identifying the soluble (ionic and nonionic) components by reacting a currently dormant environment can provide a "picture" of the thermodynamics and chemical components of a possibly bioactive environment. The only devices which can provide such information are electrochemical sensors based on the potentiometric ion selective electrodes (ISEs) and on dynamic techniques such as cyclic voltammetry (CV) and stripping voltammetry (SV). Such an array of devices can provide not only the chemical composition of a water-soluble Martian soil sample, but also several other vital chemical parameters such as pH, conductivity, redox potential, and dissolved gases. To address these issues we have been investigating the possible use of an electrochemically-based ion sensor array as a new integrated approach to quantitative analytical and chemometric electrochemical measurements. The sensor array will consist of specific and semispecific ion selective and amperometric transducers, which can simultaneously and continuously identify and semiquantitatively determine over 50 organic and inorganic analytes in water-based environments. Several individual sensors, based on the same principle, have been flight-tested and have been installed as part of the MECA instrumentation on the Mars 2001 Lander for in-situ analyses. However, the microfabrication, integration and multiplexing of such a large number of these sensors on a single substrate have not been previously attempted.

Kounaves, S. P.↗

High-Resolution Gamma-Ray Imaging Measurements Using Externally Segmented Germanium Detectors

Fully two-dimensional gamma-ray imaging with simultaneous high-resolution spectroscopy has been demonstrated using an externally segmented germanium sensor. The system employs a single high-purity coaxial detector with its outer electrode segmented into 5 distinct charge collection regions and a lead coded aperture with a uniformly redundant array (URA) pattern. A series of one-dimensional responses was collected around 511 keV while the system was rotated in steps through 180 degrees. A non-negative, linear least-squares algorithm was then employed to reconstruct a 2-dimensional image. Corrections for multiple scattering in the detector, and the finite distance of source and detector are made in the reconstruction process.

spectroscopy gamma ray germanium sensor nucleosynt↗

Modeling and simulation of electron transport at the nanoscale: illustrations in low-dimensional carbon nanostructures

This chapter showcases a few selected illustrations of various manifestations of nanoscale and molecular electronic effects as investigated by quantum mechanical methods. The examples include results demonstrating (1) how graphitic nanoribbons can be assembled into multi-terminal networks and the influence on electron transport; (2) how the position of a single embedded molecule can be modified to change the overall conduction state of a nanowire; (3) how quantum chemical modeling can lead to the design of electrodes with enhanced interface for molecular coupling; (4) how carbon nanotubes can be assembled into complex covalent arrays and how these can be obtained experimentally; (5) how quantum interference can be understood as emerging from the presence of multiple level of confinements in carbon nanorings; and (6) how new functionality can emerge at the nanoscale due the the interplay of magnetic, electronic, and structural properties of individual graphitic nanoribbons assembled into wiggly-like structures.

Meunier, V.↗

Shear horizontal surface acoustic wave (SH-SAW) resonators and arrays thereof

The present application relates to a biosensor that employs an acoustic cavity to store mechanical energy. In particular examples, the biosensor includes an electrode region and one or more reflector regions to form the acoustic cavity, as well as a functionalized active area disposed in proximity to the cavity. Methods of making and using such biosensors are also described herein.

Branch, Darren W.↗

Fabrication of Gate-Electrode Integrated Carbon-Nanotube Bundle Field Emitters

A continuing effort to develop carbon-nanotube-based field emitters (cold cathodes) as high-current-density electron sources has yielded an optimized device design and a fabrication scheme to implement the design. One major element of the device design is to use a planar array of bundles of carbon nanotubes as the field-emission tips and to optimize the critical dimensions of the array (principally, heights of bundles and distances between them) to obtain high area-averaged current density and high reliability over a long operational lifetime a concept that was discussed in more detail in Arrays of Bundles of Carbon Nanotubes as Field Emitters (NPO-40817), NASA Tech Briefs, Vol. 31, No. 2 (February 2007), page 58. Another major element of the design is to configure the gate electrodes (anodes used to extract, accelerate, and/or focus electrons) as a ring that overhangs a recess wherein the bundles of nanotubes are located, such that by virtue of the proximity between the ring and the bundles, a relatively low applied potential suffices to generate the large electric field needed for emission of electrons.

Toda, Risaku↗

Lifetime and linewidth of individual quantum dots interfaced with graphene

Here, we report on luminescence lifetimes and linewidths from an array of individual quantum dots (QDs) that were either interfaced with graphene surface guides or dispersed on aluminum electrodes. The observed fluorescence quenching is consistent with screening by charge carriers. Fluorescence quenching is typically mentioned as a sign that chromophores are interfacing with a conductive surface (metal or graphene); we find that the QDs interfaced with the metal film exhibit shortened lifetime and line-broadening but not necessarily fluorescence quenching as the latter may be impacted by molecular concentration, reflectivity and conductor imperfections. We also comment on angle-dependent lifetime measurements, which we postulate depend on the specifics of the local density-of-states involved.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Development of large area CCD imagers

High performance CCD imagers with 800 x 50 resolution elements were fabricated using a coplanar, double polysilicon, electrode system. The imager was developed as a prototype to demonstrate the feasibility of an 800 x 800 array for application to deep space photography where data rates of 10K to the 2nd power and operating temperatures of -40 C are required. The performance is discussed and comparisons made to the existing 400 x 400 imager.

Taylor, G. W.↗

Electrochemical approaches for chemical and biological analysis on Mars

Obtaining in situ chemical data from planetary bodies such as Mars or Europa can present significant challenges. The one analytical technique that has many of the requisite characteristics to meet such a challenge is electroanalysis. Described here are three electroanalytical devices designed for in situ geochemical and biological analysis on Mars. The Mars Environmental Compatibility Assessment (MECA) was built and flight qualified for the now cancelled NASA Mars 2001 Lander. Part of MECA consisted of four "cells" containing arrays of electrochemical based sensors for measuring the ionic species in soil samples. A next-generation MECA, the Robotic Chemical Analysis Laboratory (RCAL), uses a carousel-type system to allow for greater customization of analytical procedures. A second instrument, proposed as part of the 2007 CryoScout mission, consists of a flow-through inorganic chemical analyzer (MICA). CryoScout is a torpedo-like device designed for subsurface investigation of the stratigraphic climate record embedded in Mars' north polar cap. As the CryoScout melts its way through the ice cap, MICA will collect and analyze the meltwater for a variety of inorganics and chemical parameters. By analyzing the chemistry locked in the layers of dust, salt, and ice, geologists will be able to determine the recent history of climate, water, and atmosphere on Mars and link it to the past. Finally, electroanalysis shows its abilities in the detection of possible microorganism on Mars or elsewhere in the solar system. To identify an unknown microorganism, one that may not even use Earth-type biochemistry, requires a detection scheme which makes minimal assumptions and looks for the most general features. Recent work has demonstrated that the use of an array of electrochemical sensors which monitors the changes in a solution via electrical conductivity, pH, and ion selective electrodes, can be used to detect minute chemical perturbations caused by the growth of bacteria and with the correct methodology provide unamibiguous detection of such life forms.

Non-NASA Center↗

Microshutter Arrays for James Webb Space Telescope

Two-dimensional MEMS microshutter arrays are being developed at NASA Goddard Space Flight Center for use in the near-infrared region on the James Webb Space Telescope (JWST). The microshutter arrays are designed for the selective transmission of light with high efficiency and high contrast. The JWST environment requires cryogenic operation at 35K. Microshutter arrays are fabricated out of silicon-oxide-insulated (SOI) silicon wafers. Arrays are close-packed silicon nitride membranes with a pixel size of 100x200 p. Individual shutters are patterned with a torsion flexure permitting shutters to open 90 degrees with a minimized mechanical stress concentration. The mechanical shutter arrays are fabricated using MEMS technologies. The processing includes a multi- layer metal deposition and patterning of shutter electrodes and magnetic pads, reactive ion etching (NE) of the front side to form shutters out of the nitride membrane, an anisotropic back-etch for wafer thinning, followed by a deep RIE (DRIE) back-etch down to the nitride shutter membrane to form W e s and relieve shutters from the silicon substrate. An additional metal deposition and patterning is used to form back electrodes. Shutters are actuated using a magnetic force and latched using an electrostatic force. . . . KEYWORDS: microshutter, MEMS, RIE, DRIE, micro-optics, near inbred, space telescope

Li, Mary J.↗

Improved Devices for Collecting Sweat for Chemical Analysis

Improved devices have been proposed for collecting sweat for biochemical analysis especially for determination of the concentration of Ca2+ ions in sweat as a measure of loss of Ca from bones. Unlike commercially available sweat-collection patches used previously in monitoring osteoporosis and in qualitative screening for some drugs, the proposed devices would not allow evaporation of the volatile chemical components (mostly water) of sweat. Moreover, the proposed devices would be designed to enable determination of the volumes of collected sweat. From these volumes and the quantities of Ca2+ and/or other analytes as determined by other means summarized below, one could determine the concentrations of the analytes in sweat. A device according to the proposal would be flexible and would be worn like a commercial sweat-collection patch. It would be made of molded polydimethylsiloxane (silicone rubber) or other suitable material having properties that, for the purpose of analyzing sweat, are similar to those of glass. The die for molding the silicone rubber would be fabricated by a combination of lithography and electroplating. The die would reproducibly form, in the silicone rubber, a precisely defined number of capillary channels per unit area, each channel having a precisely defined volume. Optionally, electrodes for measuring the Ca2+ content of the sweat could be incorporated into the device. The volume of sweat collected in the capillary channels of the device would be determined from (1) the amount of light or radio waves of a given wavelength absorbed by the device and (2) the known geometry of the array of capillary channels. Then, in one of two options, centrifugation would be performed to move the sweat from the capillary tubes to the region containing the electrodes, which would be used to measure the Ca2+ content by a standard technique. In the other option, centrifugation would be performed to remove the sweat from the device to make the sweat available to other analytical instruments for measuring concentrations of substances other than Ca2+.

Feeback, Daniel L.↗

Carbon Nanotube Tower-Based Supercapacitor

A supercapacitor system, including (i) first and second, spaced apart planar collectors, (ii) first and second arrays of multi-wall carbon nanotube (MWCNT) towers or single wall carbon nanotube (SWCNT) towers, serving as electrodes, that extend between the first and second collectors where the nanotube towers are grown directly on the collector surfaces without deposition of a catalyst and without deposition of a binder material on the collector surfaces, and (iii) a porous separator module having a transverse area that is substantially the same as the transverse area of at least one electrode, where (iv) at least one nanotube tower is functionalized to permit or encourage the tower to behave as a hydrophilic structure, with increased surface wettability.

Meyyappan, Meyya↗

Freestanding three-dimensional core–shell nanoarrays for lithium-ion battery anodes

Here, structural degradation and low conductivity of transition-metal oxides lead to severe capacity fading in lithium-ion batteries. Recent efforts to solve this issue have mainly focused on using nanocomposites or hybrids by integrating nanosized metal oxides with conducting additives. Here we design specific hierarchical structures and demonstrate their use in flexible, large-area anode assemblies. Fabrication of these anodes is achieved via oxidative growth of copper oxide nanowires onto copper substrates followed by radio-frequency sputtering of carbon-nitride films, forming freestanding three-dimensional arrays with core–shell nano-architecture. Cable-like copper oxide/carbon-nitride core–shell nanostructures accommodate the volume change during lithiation-delithiation processes, the three-dimensional arrays provide abundant electroactive zones and electron/ion transport paths, and the monolithic sandwich-type configuration without additional binders or conductive agents improves energy/power densities of the whole electrode.

25 ENERGY STORAGE↗

Nanostructures for Electrical Energy Storage (NEES) (2020 Final Technical Report)

Nanostructures for Electrical Energy Storage (NEES, www.efrc.umd.edu) was an Energy Frontier Research Center supported by the DOE Office of Science, Basic Energy Sciences, from 8/1/2009 to 7/31/2020. Led by the University of Maryland, NEES enjoyed extensive collaborations with its funded partners, including two DOE Laboratories and six universities. The NEES vision has been to reveal a set of scientific insights and design principles that can underpin a next-generation electrical energy storage approach, building on advances in nanoscale science and technology to achieve simultaneous high power and high energy over extended charge/discharge cycling. The vision is motivated by the recognition that scaling into the nano regime opens the door to new physical phenomena and that the tools enlisted in nanoscale research provide major new opportunities for the synthesis not only of materials at molecular scale but for structures at nano scale and above. NEES has translated this vision into its research program based on two observations. First, while the behavior of ions and electrons in electrolytes and in electrode materials is crucial to electrical energy storage (or more appropriately electrochemical energy storage), it is the transport of ion and electron charge between different structural components of a storage device that ultimately determine its performance. With it well recognized that the choice of electrode materials typically constrain ion transport kinetics as well as maximum ion concentration, the search for better electrode materials has been a primary driver of battery research. At the same time the synthesis of electrodes is typically based on aggregation of particles with varying size, shape, and orientation in the electrode. Together with the presence of additional materials to impart electrical conductivity and cohesion to the composite electrode, change in electrode materials is necessarily accompanied by structural changes at the nano/micro scale that are difficult to categorize and manage. From the beginning, NEES’ vision has been to create and study simpler, highly controlled spatial arrangements of known materials as battery components (electrodes, current collectors, and electrolyte) and to understand how design and structure above the molecular scale determines the energy storage performance available from known materials. Second, advances in nanoscience dramatically expanded the portfolio of synthesis methods, structural motifs, and new phenomena available for research. Some of these gave rapid access to new building blocks at the deep nanoscale (e.g., carbon nanotubes grown by self-assembly, nanoscale arrays formed by electrochemical self-alignment, monolayer films controlled by self-limiting reaction). Such advances served as the enabler for the NEES vision to be pursued experimentally through study of 3D structures created and controlled at the nano, micro, and meso scales. Here, we use meso as in the BES MESO Report, implying not only intermediate or varying length scales, but very much the way behavior is influenced by other factors including aggregation of nanocomponents at different densities and spatial configurations, statistical variations in the aggregates, hierarchical architectures in which they can be assembled, or local 3D configurations that result from the architectures. Over its life cycle, NEES has pursued two overarching goals: (1) to understand the scientific fundamentals of electrochemical storage from the nanoscale to the mesoscale; and (2) to create and learn from innovative, controlled, heterogeneous nanostructures, where such nanostructures can enable the first goal and serve as models for future paradigms in energy storage. Specific goals have included: Synthesize heterogeneous nanostructures comprised of multiple materials arranged in controlled fashion and characterize their behavior; Demonstrate and elucidate design principles for achieving simultaneous high power and high energy; Develop materials processes which enable precision control of thin layers and 3D structures; Investigate the impact of artificial interphases on electrode stability during ion insertion/deinsertion; Create dense arrays of nanostructures to understand how the architecture of these assemblies, along with nanostructure design, influences energy storage behavior at the mesoscale; Identify and understand the consequences of nanoconfinement and local inhomogeneities in 3D mesoscale arrays; Develop and apply computational models to stimulate, guide and interpret experiments.

25 ENERGY STORAGE↗

Improved Devices for Collecting Sweat for Chemical Analysis

Improved devices have been proposed for collecting sweat for biochemical analysis - especially for determination of the concentration of Ca2+ ions in sweat as a measure of loss of Ca from bones. Unlike commercially available sweat-collection patches used previously in monitoring osteoporosis and in qualitative screening for some drugs, the proposed devices would not allow evaporation of the volatile chemical components (mostly water) of sweat. Moreover, the proposed devices would be designed to enable determination of the volumes of collected sweat. From these volumes and the quantities of Ca(2+) and/or other analytes as determined by other means summarized below, one could determine the concentrations of the analytes in sweat. A device according to the proposal would be flexible and would be worn like a commercial sweat-collection patch. It would be made of molded polydimethylsiloxane (silicone rubber) or other suitable material having properties that, for the purpose of analyzing sweat, are similar to those of glass. The die for molding the silicone rubber would be fabricated by a combination of lithography and electroplating. The die would reproducibly form, in the silicone rubber, a precisely defined number of capillary channels per unit area, each channel having a precisely defined volume. Optionally, electrodes for measuring the Ca(2+) content of the sweat could be incorporated into the device. The volume of sweat collected in the capillary channels of the device would be determined from (1) the amount of light or radio waves of a given wavelength absorbed by the device and (2) the known geometry of the array of capillary channels. Then, in one of two options, centrifugation would be performed to move the sweat from the capillary tubes to the region containing the electrodes, which would be used to measure the Ca(2+) content by a standard technique. In the other option, centrifugation would be performed to remove the sweat from the device to make the sweat available to other analytical instruments for measuring concentrations of substances other than Ca(2+).

Feedback, Daniel L.↗

Sensitivity Analysis and Effective Parametrization of PEM Fuel Cell Models

The cost of proton-exchange-membrane fuel cells (PEMFCs) remains a major hurdle in large-scale commercialization of this technology. To improve their performance and reduce cost, novel materials and electrode designs are continuously envisioned, e.g., non-PGM catalyst layers, ultra-thin Pt/Pt-Ni based catalyst layers, structured ionomer arrays or NSTF catalyst layers.1 Understanding the impact of these improvement strategies can be extremely time and cost intensive due to complex physical phenomena and large design space. We have previously developed a PEMFC modeling framework2 which has been a time and cost effective tool for understanding and optimizing the complex multi-physics phenomena within PEMFCs; however, several of the cell parameters used in the modeling have large spread in measured data.3 Furthermore, several transport parameters such as water adsorption kinetics have not been accurately measured and the approximations are spread over several orders of magnitude. These uncertainties cause problems in ascertaining accuracy of the modeling approach and they reduce the predictive power of the numerical models. The aim of this work is to identify the sensitivity of PEFC numerical model outputs to various input parameters. The previously in-house developed MEA modeling framework2 is used for PEMFC modeling. The sensitivity of the model outputs with respect to inputs parameters is obtained by analyzing the condition numbers for different output-input pairs at varying operating conditions. An example of the sensitivity analysis is shown in Figure 1. The condition numbers are obtained for the entire possible range of input parameters at varying operating conditions to identify the most crucial parameters of the PEMFC model. Based on our preliminary analysis, parameters related to kinetics (exchange current density and ECSA) and heat/water management in electrodes and ionomer (ionomer fraction, thermal conductivity) are most crucial. One of the major goals of this work is to identify the most crucial set of parameters towards which the model shows maximum sensitivity. This will guide future experimentalists to measure these properties with higher accuracy. Furthermore, the sensitivity analysis will also enable us to optimize the PEMFC performance by selectively targeting the most sensitive parameters and thereby making the largest impact. Acknowledgements The work is funded under the Fuel Cell Performance and Durability Consortium (FC-PAD), by the Fuel Cell Technologies Office (FCTO), Office of Energy Efficiency and Renewable Energy (EERE), of the U.S. Department of Energy under contract number DE-AC02-05CH11231. The authors would like to thank Nathan Craig at Robert Bosch LLC for his valuable input in designing the sensitivity analysis. The authors would also like to thank Giovanna Bucci and Matthias Hanauer at Robert Bosch for their valuable inputs and discussion. References P. K. Sinha, W. Gu, A. Kongkanand and E. Thompson, J. Electrochem. Soc., 158, B831 (2011). L. M. Pant, M. R. Gerhardt, N. Macauley, R. Mukundan, R. L. Borup and A. Z. Weber, Electrochim. Acta, 326, 134963 (2019). R. Vetter and J. O. Schumacher, ArXiv181110091 Phys. (2018). Figure 1

Pant, Lalit↗