Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

A Field-Enhanced Conduction-Cooled Superconducting Cavity for High-Repetition-Rate Ultrafast Electron Bunch Generation

High-repetition-rate sources of bright electron bunches have a wide range of applications. They can directly be employed as probes in electron-scattering setups, or serve as a backbone for the generation of radiation over a broad range of the electromagnetic spectrum. This paper describes the development of a compact sub-Mega-electronvolt (sub-MeV) electron-source setup capable of operating at MHz repetition rates and forming sub-picosecond electron bunches with transverse emittance below 20 nm. The setup relies on a conduction-cooled superconducting single-cell resonator with its geometry altered to enhance the field at the surface of the emitter. The system is designed to accommodate cooling using a 2 W pulse-tube cryogen-free cryocooler operated at 4.2 K. Although we focus on the case of a photoemitted electron bunch, the scheme could be adapted to other emission mechanisms.

43 PARTICLE ACCELERATORS↗

Near-Monochromatic Tuneable Cryogenic Niobium Electron Field Emitter

We report creating, manipulating, and detecting coherent electrons is at the heart of future quantum microscopy and spectroscopy technologies. Leveraging and specifically altering the quantum features of an electron beam source at low temperatures can enhance its emission properties. Here, we describe electron field emission from a monocrystalline, superconducting niobium nanotip at a temperature of 5.9 K. The emitted electron energy spectrum reveals an ultranarrow distribution down to 16 meV due to tunable resonant tunneling field emission via localized band states at a nanoprotrusion’s apex and a cutoff at the sharp low-temperature Fermi edge. This is an order of magnitude lower than for conventional field emission electron sources. The self-focusing geometry of the tip leads to emission in an angle of 3.7°, a reduced brightness of 3.8 × 10 8 A/(m 2 srV), and a stability of hours at 4.1 nA beam current and 69 meV energy width. This source will decrease the impact of lens aberration and enable new modes in low-energy electron microscopy, electron energy loss spectroscopy, and high-resolution vibrational spectroscopy.

36 MATERIALS SCIENCE↗

Jupiter's magnetotail as the source of interplanetary Jovian MeV electrons observed at earth

The source of interplanetary Jovian MeV electron enhancements observed at earth is found to be Jupiter's magnetotail. If an average solar wind speed of 400 km/sec is assumed, the main region of emission extends from about 1.0 AU downstream from Jupiter to about 2.0 AU beyond the planet. (If a value of 350 km/sec is assumed, it extends from about 0.4 AU to about 1.2 AU.) Individual 'active' zones are about 0.2 AU in length. It is proposed that interplanetary magnetic field line connection with the tail is the mechanism providing the Jovian electrons observed at earth.

Pesses, M. E.↗

Electron distributions in the inner Jovian magnetosphere: Voyager 1 observations

Using several improvements in the analysis of the observations of the Low Energy Charged Particle (LECP) experiment on Voyager 1, electron phase space densities in the inner Jovian magnetosphere (5 - 10 R(sub J) were first calculated at constant first and second invariants (represented by mu and K, respectively), based on the LECP measurements. The calculated electron phase space density profiles show that in the inner Jovian magnetosphere there exist evident time and longitude variations, energetic electron injections, and present radial transport and distributed losses. To study the radial and pitch angle diffusions of Jovian electrons, we have calculated the phase space densities in the K-L space. It is found that the electron population in the inner Jovian magnetosphere seems to consist of two components: electrons radially diffusing from a main external source and electrons generated from local sources. The radially diffusing electrons have a relatively time stationary and isotropic distribution, while the locally created electrons mainly concentrate around the equatorial plane and have relatively lower energies, in comparison with the inward diffusing electrons. Consequently, the sources of precipitation losses to the ionosphere must be primarily electrons transported from outer sources, and the major precipitations occur in the inner magnetosphere (L less than 7.5 R(sub J). In the inner Jovian magnetosphere (L = 5 to approximately 10 R(sub J)) it is estimated that for electrons with magnetic moment mu = 300 MeV/G, the diffusion coefficient D is roughly 10(exp -8) to approximately 10(exp -6) R(exp 2)(sub J)/s, and the lifetime against the diffusion losses is of the order of 10(exp 4) to approximately 10(exp 6) s.

Ye, G.↗

Study of Ion Generation by a ps-laser for External Injection into Electron Beam Ion Source

We investigated ion generation from Al, Ti, Cu, Nb and Ta target elements by a picosecond-laser in the range of 10 11 – 10 13 W/cm 2 power densities at the target surface. A ps-laser with 1.27 mJ maximum energy within a 8 ps pulse and repetition rate up to 400 Hz has been used to generate a laser-ablated plasma. Dependencies of ion current vs time, total charge of registered ions as well as ion kinetic energy distributions are characterized using a Faraday cup. Significant difference in ion current dynamics between first, second and following shots onto the same target spot was found for all five target elements. The total charge of ions registered by the Faraday cup increase linearly with increasing laser pulse energy and are almost independent on the target element and number of shots onto the same target spot for all five target elements studied. Target craters have been examined using a commercially available microscope (Nikon Eclipse LV150) and crater cross section areas were found to be in the range of 0.0076 – 0.0172 mm 2 within the first five shots onto the same target spot for different target elements. A linear dependence of crater cross section square on laser pulse energy has been observed for the Ta target. Ion energy distributions for all target elements have a plateau or a slight peak in the energy range of 10 - 100 eV and long low-intensity energy tail up to tens of keV.

43 PARTICLE ACCELERATORS↗

Electron-bombardment ion source operation using various gases.

Description of a modified flight-type SERT II ion thruster operated with xenon, krypton, argon, neon, nitrogen, helium, and carbon dioxide. The discharge performance with xenon, krypton, and argon was found to be similar to that obtained previously with mercury. Mass spectrometer data indicated that xenon could be operated efficiently with no significant multiple ionization. Restriction of the beam area, with an associated decrease in discharge potential, was necessary to reduce multiple ionization with argon to a negligible level. This modification also resulted in more stable operation of the thruster. Performance with the remaining gases was poor, but some future performance improvements may be realizable.

Byers, D. C.↗

The position and size of radio sources associated with solar electron events

The positions and sizes of the sources of type 3 bursts which are associated with interplanetary electron events ( 45 keV) are observed by the 80-MHz Culgoora radioheliograph. The sizes of the responsible electron streams at 0.6 solar radius in the corona are much smaller than the cones of propagation of the electrons in interplanetary space. Many of the type 3 bursts are shown to be accompanied by a type 5 continuum, and it is argued that the observation of a type 3 to 5 radio burst implies an increased spreading of electrons at heights 0.6 solar radius, consistent with the extent of the propagation cone of the electrons in interplanetary space.

Palmer, I. D.↗

Free-electron laser inverse-Compton interaction x-ray source

Free-electron lasers (FEL) and synchrotron sources of high brilliance x-rays have been confirmed to be of tremendous value in basic and applied research. Inverse-Compton sources (ICS) can achieve brilliance matching the requirements of many applications pioneered at those FEL and synchrotron facilities—including phase contrast imaging, macromolecular x-ray crystallography, and x-ray microscopy—but with size, cost, and complexity compatible with a small laboratory. The free-electron laser inverse-Compton interaction compact x-ray source at the University of Hawaii at Manoa is a unique approach to an ICS which employs an FEL as the laser source. We have measured a total average flux of 3.0 × 10 5 photons / second with an average brilliance of 2.0 × 10 7 photons / s mm 2 mrad 2 0.1% of bandwidth (BW) with a peak energy of 10.9 keV from the source. While these results are modest in comparison to the standards set by other IC sources, upgrades to the system have the potential to increase the total average flux to 9.2 × 10 11 photons / second with an average brilliance of 1.9 × 10 12 photons / s mm 2 mrad 2 0.1% BW: comparing more favorably to other sources. We discuss the scientific program, the progress made in design and development, and the achievements of the source to date. We also outline future upgrades and integration needed to yield an enabling source for emerging high brilliance x-ray applications.

43 PARTICLE ACCELERATORS↗

Spherical ion source

Radial focusing of electrons in ion source produces greater ion densities, resulting in higher resolution and focus capability for a given source volume. Electron beam is focused near exit aperture by spherical fields. High density ions allow focusing ion beam to high density at echo, allowing high current through small aperture.

Hall, L. G.↗

High efficiency, high-current laser-driven electron injector (CRADA Final Report)

Owing to ultra-high fields sustainable in a plasma, laser-plasma accelerator technology enables compact, high-brightness, sources of electron beams. This work investigates novel electron injection methods. Key to this research is to understand laser energy and pointing stability and to develop methods and techniques to control fluctuations. This project benefits other areas of scientific inquiry by developing a high-repetition rate, high-brightness electron source for probing materials and ultra-fast processes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High efficiency, high-current laser-driven electron injector (CRADA Final Report)

Owing to ultra-high fields sustainable in a plasma, laser-plasma accelerator technology enables compact, high-brightness, sources of electron beams. This work investigates novel electron injection methods. Key to this research is to understand laser energy and pointing stability and to develop methods and techniques to control fluctuations. This project benefits other areas of scientific inquiry by developing a high-repetition rate, high-brightness electron source for probing materials and ultra-fast processes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗