Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy reductions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

liionpack: A Python package for simulating packs of batteries with PyBaMM

Electrification of transport and other energy intensive activities is of growing importance as it provides an underpinning method to reduce carbon emissions. With an increase in reliance on renewable sources of energy and a reduction in the use of more predictable fossil fuels in both stationary and mobile applications, energy storage will play a pivotal role and batteries are currently the most widely adopted and versatile form. Therefore, understanding how batteries work, how they degrade, and how to optimize and manage their operation at large scales is critical to achieving emission reduction targets. The electric vehicle (EV) industry requires a considerable number of batteries even for a single vehicle, sometimes numbering in the thousands if smaller cells are used, and the dynamics and degradation of these systems, as well as large stationary power systems, is not that well understood. As increases in the efficiency of a single battery become diminishing for standard commercially available chemistries, gains made at the system level become more important and can potentially be realised more quickly compared with developing new chemistries. Mathematical models and simulations provide a way to address these challenging questions and can aid the engineer and designers of batteries and battery management systems to provide longer lasting and more efficient energy storage systems.

25 ENERGY STORAGE↗

Photoelectrochemical Nitrogen Reduction to Ammonia on Cupric and Cuprous Oxide Photocathodes

Photoelectrochemical N 2 reduction enables the production of NH 3 under ambient conditions using water as the hydrogen source. Furthermore, by utilizing solar energy, photoelectrochemical N 2 reduction can significantly reduce the energy input required for N 2 reduction. In this study, photoelectrochemical N 2 production was investigated using CuO and Cu 2 O photocathodes that are known to be poorly catalytic for water reduction, the major reaction competing with N 2 reduction. When tested under simulated solar illumination with isotopically labeled 15 N 2 in 0.1 M KOH solution, the CuO and Cu 2 O photocathodes produced 15 NH 3 with a Faradaic efficiency of 17% and 20% at 0.6 V and 0.4 V vs. RHE, respectively. These potentials are significantly more positive than the thermodynamic reduction potential of N 2 , which demonstrates how the use of photoexcited electrons in the CuO and Cu 2 O photocathodes can reduce the energy input required for NH 3 production. Here, the use of photoexcited electrons in these photocathodes for N 2 reduction, water reduction, and photocorrosion was carefully examined.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reductive catalytic fractionation of agricultural residue and energy crop lignin and application of lignin oil as antimicrobials

Cheap and abundant waste from bioethanol and agricultural processing industries are an alluring alternative feedstock for biorefineries. In this work, we employ reductive catalytic fractionation (RCF) to depolymerize, over Ru/C powder and Ru/Al 2 O 3 pellets, five herbaceous biomass feedstocks, namely corn stover, miscanthus, switchgrass, sugarcane bagasse, and wheat straw into phenolic monomers with high yields (~40 wt.% based on total (Klason + acid soluble) lignin and > 50 wt.% when stabilized using aldehydes), leaving behind a carbohydrate pulp residue. Interestingly, a polar solvent is sufficient to solubilize and fragment the lignin polymer into monomers without any catalyst. Here, contrary to woody biomass, where the monomer yields are positively correlated with the S-content of lignin, principal component analysis indicates that the monomer yields from herbaceous biomass depend on the content of lignin crosslinker – ferulate. Using NMR, we further identify α – 6 C-C linked oligomers formed from condensation reactions, explaining the unexpected low monomer yields of high β-O-4 herbaceous biomass. Recyclability experiments indicate that catalyst deactivation occurs through sintering, leaching, and fouling. Lignin oil from herbaceous biomass exhibits bacteriostatic effects against Staphylococcus aureus, highlighting a potential application in functional food development and as food or feed preservative.

09 BIOMASS FUELS↗

Atomistic Insight into Cation Effects on Binding Energies in Cu-Catalyzed Carbon Dioxide Reduction

Electrolyte properties in general and electrolyte ions in particular have been shown to have significant effects on the kinetics of electrochemical CO 2 and CO reduction at metal electrodes, but these effects have not yet been fully understood. Here, we investigate the effects of cations at the aqueous electrolyte–Cu(211) interface on adsorbate binding energies and the electrolyte structure using density functional theory (DFT). Charging the interface via explicit Na + has systematic effects on adsorbate–electrolyte interactions and conformations. We describe specific local adsorbate–ion interactions, including direct alkali ion–adsorbate coordination and hydrogen bonding via ion-coordinated water molecules. The relative importance of these specific interactions and purely electrostatic field–adsorbate interactions is investigated by comparing the DFT-calculated ion effects to those predicted by purely electrostatic models of the interface and the adsorbates. We find that the trend in ion effects among different adsorbates at constant surface charge density is well explained by a purely electrostatic interaction model. The binding energy of OCCHO is found to depend strongly on the surface charge density as well as the spatial distribution of ions at constant surface charge density. These effects are also explained by a purely electrostatic local electrostatic field–adsorbate model. This indicates that alkali ion effects can be mainly attributed to purely electrostatic field interactions and that the local field at ion-stabilized active sites can depend significantly on both the overall charge density and on the spatial distribution of ions at constant charge density. This work provides new insight on alkali ion effects on a variety of adsorbates relevant to the CO 2 and CO reduction reactions by describing specific local ion–adsorbate interactions, systematic changes in adsorbate–electrolyte interactions induced by explicit surface charge, and comparisons of the calculated effects on binding energies to simple electrostatic field–adsorbate models to explain trends among various adsorbates and at varying surface charge densities and supercell configurations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

West Virginia University Industrial Assessment Center (Final Progress Report)

The Industrial Assessment Center at West Virginia University has been successful in workforce development, and in generation of energy savings for manufacturing facilities during the period 2016 to 2021. Graduate and undergraduate students have benefited from energy assessment experience and most of them have found good positions as energy engineers and analysts in the industrial sector. Several peer reviewed research papers in archival journals as well as conference papers on the topic of energy engineering and assessment have been published. The implemented energy savings for manufacturing facilities have been significant in the areas of lighting, compressed air, process heating, steam, HVAC, chillers and cooling towers, and motors. In addition, water use reduction, smart manufacturing applications to save energy, cyber security evaluation, energy management, productivity improvements and waste reduction opportunities that lead to energy intensity reductions have been explored. The students have obtained an opportunity to interact with energy efficiency and productivity improvement professionals at various conferences and workshops and their research has generated important results. In summary, the West Virginia University Industrial Assessment Center (WVU-IAC) has fulfilled its mission in regard to workforce development, energy efficiency for manufacturing facilities, and laid a strong platform enhancing sustainability through reductions in carbon emissions achieved through energy efficiency and energy management initiatives and reductions in water usage and waste reduction. During the project period (2016-2021) the WVU-IAC has made numerous energy efficiency, water use reduction, waste reduction, and productivity improvement recommendations, a significant number of them having been implemented by the manufacturing facilities. The research adds significant understanding to the area of energy efficiency, water and waste reduction, and productivity improvement. The technical effectiveness and economic feasibility of the methods and techniques investigated and demonstrated through this project have been exemplary, resulting in significant recommended and implemented resource savings and reductions in carbon emissions. The project has been of significant benefit to the public owing to replication of results within the industrial sector, thus reducing operating costs for businesses that result in increase of growth and employment, as well as community benefits in terms of reductions in carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Valued peaks: Sustainable water allocation for small hydropower plants in an era of explicit ecological needs

Optimizing hydropower operations to balance economic profitability and support functioning ecosystem services is integral to river management policy. In this article, we propose a dynamic, constrained optimization framework for small hydropower plants (SHPs) to evaluate trade-offs between economic profitability and socio-ecological requirements. Specifically, we examine the balance between short-term losses in hydropower generation and the potential for compensatory benefits in the form of revenue from recreational ecosystem services, irrespective of the direct beneficiary. Our framework integrates a fish habitat model, a hydropower optimization model, and a recreational ecosystem service estimate to evaluate different environmental flow scenarios. The optimization process gives three outflow release scenarios, informed by previous streamflow realisations (dam inflow), and designed environmental flow constraints. The framework is applied and tested for the river Kuusinkijoki in North-eastern Finland, which is a habitat for migratory brown trout and grayling populations. We show that the revenue loss due to the environmental flow constraints arises through a reduction in revenue per generated energy unit and through a reduction in turbine efficiency. Additionally, the simulation results reveal that all the designed environmental flow constraints cannot be met simultaneously. Under the environmental flow scenario with both minimum flow and flow ramping rate constraints, the annual hydropower revenue decreases by 16.5 %. An annual increase of 8 % in recreational fishing visits offsets the revenue loss. In conclusion, the developed framework provides knowledge of the costs and benefits of hydropower environmental flow constraints and guides the prioritizing process of environmental measures.

13 HYDRO ENERGY↗

Frozen Freedom: Unleashing Grocery Store Demand Flexibility: Preprint

Grocery stores consumed approximately 3% of total electricity used by commercial buildings in the U.S. in 2018 (EIA 2018), representing a unique end-use load profile characterized by the critical use of refrigerated display cases. Exploring demand response (DR) scenarios in grocery stores presents an opportunity to enhance the efficiency and sustainability of surrounding communities. In addition, recent studies demonstrate that implementing control algorithms considering demand flexibility strategies can lead to load and peak reductions in standalone refrigerated display cases. Because small business grocery stores operate on thin margins, the energy bill cost savings DR might provide could make a positive difference toward continued operations. Still, uncertainty remains about the extent of demand flexibility potential controls could provide when coupling refrigeration with whole building operation. To enhance economic viability and grid stability, it is essential to quantify the load flexibility capability of grocery stores. Advanced controls can optimize energy consumption by responding to load shedding, shifting, and DR events, as well as daily Time-of-Use (TOU) rates without compromising food safety. Using both quantitative data and interviews with community-based organizations, we developed a full-size store model and two small store models with controlled refrigerated cases, HVAC, and lighting systems based on actual grocery store properties. Through simulations, we have assessed load flexibility strategies with varied DR events. The results highlight potential for energy and peak reduction with advanced or basic controls. However, interviews and data indicate that more support is needed to make DR strategies consistently accessible to small grocery stores.

demand flexibility↗

In situ catalyst activation and regeneration enable energy-efficient high-current CO 2 reduction to ethanol-rich C 2+ mixtures

Electrochemical conversion of dissolved CO 2 in bicarbonate electrolytes, i.e., bicarbonate electrolysis, offers distinct advantages over gas diffusion electrode systems by enabling direct utilization of the CO 2 capture electrolyte while bypassing the energy-intensive CO 2 release step. However, bicarbonate electrolysis faces challenges such as CO 2 mass-transfer limitation, local pH-driven CO 2 depletion, and high cathodic potentials. The higher potential often causes catalyst surface reorganization, leading to a gradual loss of active sites and variations in selectivity during CO 2 reduction. Here, we report a directed, in situ activation and regeneration method that allows precatalysts to equilibrate under dynamic (pulsed) electrolysis conditions. We demonstrate in situ activation of a scalable Cu 2 O/Cu mesh that, under short-width (t = 4 s) pulsed electrolysis, provides stable mixed oxidation states of Cu, favoring the formation of an ethanol-rich crude mixture. The pulsed electrolysis waveform, consisting of six distinct segments, is tuned to form Cu + oxides, which are then reduced to generate local alkaline conditions favoring C–C coupling. This synergistic effect results in FEs of 73% for C2+ products and 39% for ethanol at an applied current density of −150 mA cm −2 and a cathodic potential of −1.45 V (vs. RHE). The overall half-cell energy efficiency is ∼30% for C 2+ products. The in situ Raman experiments confirm the role of pCO 2 R in dynamically regenerating Cu+-containing surface species during pulsed operation, thereby steering selectivity towards C 2+ products. A comprehensive multiscale, multiphysics model is developed to investigate the dynamic behavior of copper surface species (Cu, Cu + , and Cu 2+ ) and local microenvironmental conditions during the pCO 2 R. The results reveal that the coexistence of different copper oxidation states, especially the Cu+ intermediate, is critical in steering selectivity towards multicarbon (C 2+ ) products. The dynamic modulation of surface redox states via tailored pulsing strategies favors C–C coupling pathways by inducing localized alkaline conditions and stabilizing reactive intermediates. This work establishes a predictive modeling platform that links pulse waveform design with mechanistic insights into catalyst state evolution and product selectivity. Overall, this study provides valuable insights into the synergistic effect of in situ activation of pre-catalysts and pulsed electrolysis for higher selectivity towards C 2+ products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Technoeconomic Design of a Geothermal-Enabled Cold Climate Zero Energy Community

Development of a zero energy community is more costly in northern cold climates than in moderate regions. Building energy loads are higher, thanks to the colder weather, and site solar photovoltaics (PV) are less productive due to lower solar incidence and misalignment with the buildings’ energy needs (summer production, winter demands). Geothermal energy production can support a zero energy community through application of energy efficiency (demand design), geothermal production (supply design), and asset dispatch as an integrated techno-economic package. This article presents the process used to explore geothermal system integration, our findings, and technical challenges for community-scale adoption of geothermal as an electric and thermal resource. We show that under a wide range of conditions, community-scale geothermal electric power and direct-use thermal energy is economically competitive with “business-as-usual” design and construction practices for zero energy communities. Furthermore, geothermal-produced energy will be self-consumed to a much greater extent than PV, resulting in significant reductions in site energy import and export. We conclude that under appropriate conditions, community-scale geothermal can be the most economically favorable energy resource for northern-climate zero energy community developments. Ongoing geothermal research and development to improve performance and reduce costs will further enhance the value proposition for community-scale geothermal technologies. We expect that including geothermal power and thermal energy in zero energy community design can improve its cost-effectiveness and therefore enhance the benefits of zero energy in more northern climates.

15 GEOTHERMAL ENERGY↗

Optimal Energy Measurement in Nonlinear Systems: An Application of Differential Geometry

Design of TES microcalorimeters requires a tradeoff between resolution and dynamic range. Often, experimenters will require linearity for the highest energy signals, which requires additional heat capacity be added to the detector. This results in a reduction of low energy resolution in the detector. We derive and demonstrate an algorithm that allows operation far into the nonlinear regime with little loss in spectral resolution. We use a least squares optimal filter that varies with photon energy to accommodate the nonlinearity of the detector and the non-stationarity of the noise. The fitting process we use can be seen as an application of differential geometry. This recognition provides a set of well-developed tools to extend our work to more complex situations. The proper calibration of a nonlinear microcalorimeter requires a source with densely spaced narrow lines. A pulsed laser multi-photon source is used here, and is seen to be a powerful tool for allowing us to develop practical systems with significant detector nonlinearity. The combination of our analysis techniques and the multi-photon laser source create a powerful tool for increasing the performance of future TES microcalorimeters.

Nonlinear response↗

U.S. Industrial and Commercial Motor System Market Assessment Report. Volume 3: Energy Saving Opportunity

This report seeks to inform the potential for motor systems to support decarbonization by estimating their potential energy, electricity cost, and CO 2 emissions reduction potential from adoption of proven energy efficiency actions and advanced technologies. This is the third and final report in a series of reports disseminating the findings of the U.S. Department of Energy’s (DOE’s) Motor System Market Assessment (MSMA). The MSMA and this report focus on polyphase motor systems greater than or equal to 1 horsepower (hp) in the industrial and commercial sectors. In the U.S. Industrial and Commercial Motor System Market Assessment Report Volume 1: Characteristics of the Installed Base (Volume 1 report), it was determined that these motor systems consume more than 1,000 terawatt-hours (TWh) annually. This equates to 29% of the U.S. electric grid load and results in 765 million metric tons (MMT) of CO 2 emissions and $166 billion in electricity costs. This report finds that substantial reductions to these energy, cost, and emissions impacts are possible, with three areas of significant opportunity being (1) improved load matching, (2) replacing older inefficient motors with more efficient motors, and (3) improving the condition of fluid (e.g., air, water, compressed air) distribution systems. A summary of the savings potential from these three opportunities placed within the context of the overall consumption for motor systems is illustrated in Figure ES 1 (industrial) and Figure ES 2 (commercial).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An optimization framework for the network design of advanced district thermal energy systems

In this work, a topology optimization framework for district thermal energy systems is presented. The framework seeks to address the questions, for a given district, "What is the best subset of buildings to connect to a district thermal energy system, and by what network should they be connected, to minimize life cycle cost?" A particle swarm optimization approach is validated to address the selection of the subset of buildings, and a graph theory-based heuristic is validated for selection of the network topology for any candidate subset of buildings. The framework is applied to a prototypical urban district for illustrative purposes. Additionally, modeling of prototypical districts revealed reductions in source energy use intensity for heating and cooling of 21-25% through the use of advanced district energy systems relative to code-compliant, building level systems. The framework identifies solutions with life cycle cost values 14% to 72% lower than that of base case scenarios based on conventional design approaches, depending on the base case scenario selected. Analysis of the search space indicates that topology optimization facilitates reductions in life cycle cost, source energy use intensity, and carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential high-performance magnet materials: Co- and Al-alloyed Sm 2 Fe 17

Sm 2 Fe 17 has long been known as a potential high-performance magnet whose deficiencies—planar anisotropy and lower-than-optimal T c —can be remedied by nitrogen addition, but which presents synthesis difficulties. In this work, we apply first-principles calculations to search for alternative low-cost, high-performance permanent magnets in this family, by exploring simultaneous Fe and Al substitution. Specifically, the goal is to improve properties of Sm 2 Fe 14 Al 3 easy-plane magnet at the stoichiometric composition. Density functional theory calculations were executed for three series of compounds, i.e., Sm 2 (Fe 1-x Co x ) 14 Al 3 , Sm 2 (Fe 1-x Co x ) 15 Al 2 , and Sm 2 (Fe 1-x Cox) 16 Al. We find that substitution of Fe with 12–18 of Co in % Sm 2 Fe 14 Al 3 modifies the magnetic anisotropy type from easy plane to easy axis with a substantial anisotropy of 7.1 MJ/m 3 . We also demonstrate that the largest part of magnetic anisotropy is introduced by 4f Sm atom electrons. Thus the rotation of magnetic moment orientation from $\langle$$1\bar10$$\rangle$ to $\langle$111$\rangle$ is followed by an increase of the occupied 4f state number and, as a result, the orbital part of the magnetic moment of one of the Sm atoms. This increase of the occupied 4f state number at an energy ~ -4.3 eV results in a significant reduction of band structure energy. The substitution of Fe by Co does not significantly reduce the magnetization of the compound and keeps it slightly above 1 T. This combination of magnetic anisotropy and magnetization makes the compound a promising candidate for a permanent magnet.

36 MATERIALS SCIENCE↗

Single-neutron adding on $^{34}$S

For this work, single-neutron adding data was collected in order to determine the distribution of the single-neutron strength of the 0ƒ 7/2 , 1p 3/2 , 1p 1/2 and 0ƒ 5/2 orbitals outside of Z = 16, N = 18, 34 S. The 34 S(d,p) 35 S reaction has been measured at 8 MeV/u to investigate cross sections to excited states in 35 S. Outgoing proton yields and momenta were analyzed by the Super-Enge Split-Pole Spectrograph in conjunction with the CeBrA demonstrator located at the John D. Fox Laboratory at Florida State University. Angular distributions were compared with Distorted Wave Born Approximation calculations in order to extract single-neutron spectroscopic overlaps. Spectroscopic overlaps and strengths were determined for states in S up through 6 MeV in excitation energy. Each orbital was observed to have fragmented strength where a single level carried the majority. The single-neutron centroids of the 0ƒ 7/2 , 1p 3/2 , 1p 1/2 and 0ƒ 5/2 orbitals were determined to be 2360$^{+90}_{-40}$ keV, 3280$^{+80}_{-50}$ keV, 4780$^{+60}_{-40}$ keV, and ≳7500 keV, respectively. A previous discrepancy in the literature with respect to the distribution of the neutron 1p 1/2 strength was resolved. The integration of the normalized spectroscopic strengths, up to 5.1 MeV in excitation energy, revealed fully-vacant occupancies for the 0ƒ 7/2 , 1p 3/2 , and 1p 1/2 orbitals, as expected. The spacing in the single-neutron energies highlighted a reduction in the traditional N = 28 shell-gap, relative to both the 1p spin-orbit energy difference (N = 32) and the lower limit on the N = 34 shell spacing.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Impact of anatomical fractionation of corn stover on hammer mill throughput and energy consumption

The goal of this Case Study was to quantify the impacts of variable moisture and ash on hammer mill throughput and energy consumption and on loss of very wet stover that causes failures in the first stage grinder and that are not able to be fed to conversion, as compared to a status quo Base Case system. Also considered was convertible carbohydrate content (minimum total carbohydrate specification) and maximum ash content and the delivered feedstock cost impacts of not being able to feed stover not meeting the total carbohydrate specification to the conversion reactor. Laboratory data on the impacts of moisture content and tissue fraction on throughput and energy consumption in a stage 2 hammer mill were received from FCIC Subtask 5.1. Additional air classifier throughput, energy consumption and separation efficiency data were obtained from FCIC Subtask 5.1 for the new air classifier, which has three exit streams (lights, middle and heavies). These data were utilized to develop the necessary response surface equations to perform throughput analysis using discrete event simulation. Because the ash contents and particle sizes had not been analyzed in the laboratory at the time of the model runs, we assumed that the ash distributed proportionally with total mass into the lights and heavies in an air classifier having two exit streams (lights and heavies) and that the lights fraction from the air classifier was not removed. Key takeaways from this Case Study are that due to lower energy consumption, it is more cost effective to hammer mill fractionated corn stover tissues than whole stover. Reduction of grinding energy was significant and may possibly be connected to particle-particle interactions in the grinder that lead to increased residence time of leaves and husks, resulting in decreased throughput and higher generation of fines when milling whole stover. While we did not see significant impacts to throughput, this was due to moisture failures of the first stage grinder in each system dominating failures and downtime. The operating cost savings of reduced grinding energy savings in the second stage hammer mills alone was high enough to offset the added capital cost of the air classifier and extra grinding line.

09 BIOMASS FUELS↗

Chromium isotope fractionation during reduction of Chromium(VI) by Iron(II/III)-bearing clay minerals

Chromium stable isotope ratios are used to trace the reduction of Cr(VI) to Cr(III) in both ancient and modern systems. However, quantitative interpretation of Cr isotopic signatures has been stymied by the large variability in isotopic fractionation factors for Cr(VI) reduction by different reductants. Here we determine Cr isotope fractionation factors during Cr(VI) reduction by Fe(II/III)-bearing clay minerals, which are abundant in subsurface environments. Several variables were tested: pH, total Fe content of the clay, and the fraction of reduced Fe within the clay (Fe(II)/Fe(total)). The latter controls the standard reduction potential of the clay. Our results demonstrate that neither pH nor total Fe content of the clay have major effects on isotopic fractionation. In contrast, as the effective standard reduction potential of the clay and thus the standard free energy of Cr(VI) reduction become more negative, Cr isotope fractionation factors decrease in magnitude from - 4.9 to -1.3‰ according to a linear free energy relationship. This linear free energy relationship can be predicted from Marcus electron transfer theory and allows first-order predictions of Cr isotope fractionation factors to be made from the standard reduction potential or Fe(II)/Fe(total) of a clay, potentially improving our ability to model Cr isotope signatures in geochemical systems. Chromium is the first isotope system to show such a linear free energy relationship over a diverse range of reductants, including both aqueous and solid-phase reductants, and may provide a model for determining other redox-driven kinetic isotope effects in environmentally important isotope systems.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A System Approach to Deep Heating Savings Through Measurement, Management, and Motivation

Across multi-tenant commercial office and multifamily buildings, centrally metered fuel use represents a substantial fraction of whole-building energy use. Energy audit practitioners understand that improving heating distribution efficiency is typically more of an opportunity than combustion efficiency and that differing thermal comfort preferences between tenants are the bane of operators across these building typologies. There is an unmet market need for retrofit technologies that allow for the delivery of the right amount of heat to the right spaces, at the right time. The Energy Management and Information System (EMIS) package fills this gap through enhanced controls and metering, incorporating low-cost sensors and wireless communication infrastructure to provide a platform for ongoing commissioning and tenant feedback, including heat cost allocation. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Sentient Buildings, E Source, building owners, and utility and policy stakeholders, to demonstrate a market viable EMIS that achieves a reduction in space heating energy use by reducing heating load, improving control, and positively impacting behavior while providing an acceptable financial return. In this study, EMIS packages were implemented in two New York City multifamily rental buildings. Both buildings conducted basic mechanical work (e.g., repairing steam traps) to ensure the heating system was operating well before any tenant feedback was layered in. Heating Energy Use Reports (HEUR) were created to provide tenants with social comparisons and energy savings tips to influence their behavior; these were provided monthly to all tenants in both buildings. Additionally, one building allocated heating costs to a portion of the tenants. Heat cost allocation (HCA) has a long history in the European Union (EU), although it is not common in the US or in steam-heated buildings. SWA leveraged existing EU best practices and stakeholder feedback to develop a Heat Cost Allocation algorithm that was considered equitable and intuitive. Energy use and tenant behavior impacts were tracked throughout the study. The basic mechanical repair work saved between 11-20% of heating energy. Those savings rose to 17-24% with the addition of tenant feedback. While it may not be possible to precisely determine the impact of COVID-19 on research studies like this, there may have been additional savings realized had the study taken place in a period of normal occupancy patterns. These types of central heating systems have been a blind spot for utilities, who have traditionally had little visibility into detailed behind-the-meter gas usage. Heating energy savings stayed consistent during the coldest months, indicating the potential for utilities to utilize EMIS packages for peak gas demand reductions or demand response programs. Tenant comfort was also improved. Post installation, room temperatures more closely matched thermostat set points. Perhaps due to this greater level of control, the vast majority of tenants being billed for heating were accepting of the allocation costs. And tenants receiving heat cost allocations were more likely to reduce their thermostat setpoints than tenants receiving behavioral feedback without financial impacts were. Variation in building specifics makes it difficult to provide precise energy and financial savings estimates. But within the range of expected conditions, the study identified a few key variables that can have the greatest impact on financial returns: the cost of fuel, the ability and willingness to allocate heating costs to tenants, and a well-functioning heating system as a starting point. This study focused on two multifamily buildings, but additional use cases, such as commercial buildings and affordable housing, should be explored to better understand the full market potential. While this type of upgrade has the potential for deep energy reductions and cost savings, future projects should take into account the balance of costs and benefits between owners and tenants, especially in the affordable, regulated, or other low-to-moderate income (LMI) segments of the market. Rent credits, utility allowances, or a shared savings program are possible options to accelerate adoption of this strategy in these market segments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Load-Shifting Strategies for Cost-Effective Emission Reductions at Wastewater Facilities

Significant hourly variation in the carbon intensity of electricity supplied to wastewater facilities introduces an opportunity to lower emissions by shifting the timing of their energy demand. This shift could be accomplished by storing wastewater, biogas from sludge digestion, or electricity from on-site biogas generation. However, the life cycle emissions and cost implications of these options are not clear. Here, we present a multiobjective optimization framework for comparing cost- and emission-minimizing load-shifting strategies at a California case study facility with a relatively low carbon intensity grid and high spread in peak and off-peak electricity prices. We evaluate cost and emission trade-offs from the optimal flexible operation of both existing infrastructure and optimally sized energy flexibility upgrades. We estimate energy-related emission reductions of up to 9.0% with flexible operation of existing infrastructure and up to 16.8% with optimally sized storage upgrades. Only a fraction of these potential savings are realized under actual industrial energy tariffs and the EPA’s recommended social cost of carbon. Energy flexibility may hold promise as a short-term emission-saving solution for the wastewater sector, but the extent of savings is heavily dependent on the cost of carbon, electricity tariffs, and emission intensity of the regional electricity grid.

climate↗