Search NASA⌕ Search

SEARCH · Search NASA

Results for “filter methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Detecting Weak Spectral Lines in Interferometric Data through Matched Filtering

Modern radio interferometers enable observations of spectral lines with unprecedented spatial resolution and sensitivity. In spite of these technical advances, many lines of interest are still at best weakly detected and therefore necessitate detection and analysis techniques specialized for the low signal-to-noise ratio (S/N) regime. Matched filters can leverage knowledge of the source structure and kinematics to increase sensitivity of spectral line observations. Application of the filter in the native Fourier domain improves S/N while simultaneously avoiding the computational cost and ambiguities associated with imaging, making matched filtering a fast and robust method for weak spectral line detection. We demonstrate how an approximate matched filter can be constructed from a previously observed line or from a model of the source, and we show how this filter can be used to robustly infer a detection significance for weak spectral lines. When applied to ALMA Cycle 2 observations of CH{sub 3}OH in the protoplanetary disk around TW Hya, the technique yields a ≈53% S/N boost over aperture-based spectral extraction methods, and we show that an even higher boost will be achieved for observations at higher spatial resolution. A Python-based open-source implementation of this technique is available under the MIT license at http://github.com/AstroChem/VISIBLE.

79 ASTRONOMY AND ASTROPHYSICS↗

Wideband dichroic-filter design for LED-phosphor beam-combining

A general method is disclosed of designing two-component dichroic short-pass filters operable for incidence angle distributions over the 0-30.degree. range, and specific preferred embodiments are listed. The method is based on computer optimization algorithms for an N-layer design, specifically the N-dimensional conjugate-gradient minimization of a merit function based on difference from a target transmission spectrum, as well as subsequent cycles of needle synthesis for increasing N. A key feature of the method is the initial filter design, upon which the algorithm proceeds to iterate successive design candidates with smaller merit functions. This initial design, with high-index material H and low-index L, is (0.75 H, 0.5 L, 0.75 H)^m, denoting m (20-30) repetitions of a three-layer motif, giving rise to a filter with N=2 m+1.

36 MATERIALS SCIENCE↗

Evaluation of metal artifacts in MVCT systems using a model based correction method

Purpose: To evaluate the performance of a model based image reconstruction method in reducing metal artifacts in the megavoltage computed tomography (MVCT) images of a phantom representing bilateral hip prostheses and to compare with the filtered-backprojection (FBP) technique. Methods: An iterative maximum likelihood polychromatic algorithm for CT (IMPACT) is used with an additional model for the pair/triplet production process and the energy dependent response of the detectors. The beam spectra for an in-house bench-top and TomoTherapy Trade-Mark-Sign MVCTs are modeled for use in IMPACT. The empirical energy dependent response of detectors is calculated using a constrained optimization technique that predicts the measured attenuation of the beam by various thicknesses (0-24 cm) of solid water slabs. A cylindrical (19.1 cm diameter) plexiglass phantom containing various cylindrical inserts of relative electron densities 0.295-1.695 positioned between two steel rods (2.7 cm diameter) is scanned in the bench-top MVCT that utilizes the bremsstrahlung radiation from a 6 MeV electron beam passed through 4 cm solid water on the Varian Clinac 2300C and in the imaging beam of the TomoTherapy Trade-Mark-Sign MVCT. The FBP technique in bench-top MVCT reconstructs images from raw signal normalized to air scan and corrected for beam hardening using a uniform plexiglass cylinder (20 cm diameter). The IMPACT starts with a FBP reconstructed seed image and reconstructs the final image in 150 iterations. Results: In both MVCTs, FBP produces visible dark shading in the image connecting the steel rods. In the IMPACT reconstructed images this shading is nearly removed and the uniform background is restored. The average attenuation coefficients of the inserts and the background are very close to the corresponding values in the absence of the steel inserts. In the FBP images of the bench-top MVCT, the shading causes 4%-9.5% underestimation of electron density at the central inserts with an average of (6.3 {+-} 1.8)% for the range of electron densities studied. In the uniform plexiglass background, the shadow creates 0.8%-4.7% underestimation of electron density with an average of (2.9 {+-} 1.2)%. In the corresponding IMPACT images, the underestimation in the shaded plexiglass background is 0.3%-1.8% with an average of (0.9 {+-} 0.5)% and 1.4%-6.8% with an average of (2.8 {+-} 2.7)% in the central insert region. In the FBP images of the TomoTherapy Trade-Mark-Sign MVCT, this shading creates 2.6%-6.7% underestimation of electron density with an average of (3.7 {+-} 1.4)% at the central inserts and 5.9%-7.2% underestimation in the background with an average of (6.4 {+-} 0.5)%. In the IMPACT images, the uniform background between the steel rods is restored with 0.3%-1.0% underestimation of electron density with an average of (0.7 {+-} 0.3)%. The corresponding underestimation at the central inserts of the IMPACT images is -0.4%-0.1% with an average of (-0.1 {+-} 0.2)%. Conclusions: The shading metal artifact has been nearly removed in MVCT images using the IMPACT algorithm with the accurate geometry of the system, proper modeling of energy dependent response of detectors, and all relevant photon interaction processes. This results less than 1% difference in electron density in the background plexiglass and less than 3% averaged over the range of electron densities investigated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of Snared-Loop Technique When Standard Retrieval of Inferior Vena Cava Filters Fails

Purpose To identify the success and complications related to a variant technique used to retrieve inferior vena cava filters when simple snare approach has failed. Methods A retrospective review of all Cook Guenther Tulip filters and Cook Celect filters retrieved between July 2006 and February 2008 was performed. During this period, 130 filter retrievals were attempted. In 33 cases, the standard retrieval technique failed. Retrieval was subsequently attempted with our modified retrieval technique. Results The retrieval was successful in 23 cases (mean dwell time, 171.84 days; range, 5-505 days) and unsuccessful in 10 cases (mean dwell time, 162.2 days; range, 94-360 days). Our filter retrievability rates increased from 74.6% with the standard retrieval method to 92.3% when the snared-loop technique was used. Unsuccessful retrieval was due to significant endothelialization (n = 9) and caval penetration by the filter (n = 1). A single complication occurred in the group, in a patient developing pulmonary emboli after attempted retrieval. Conclusion The technique we describe increased the retrievability of the two filters studied. Hook endothelialization is the main factor resulting in failed retrieval and continues to be a limitation with these filters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Level-set segmentation of pulmonary nodules in megavolt electronic portal images using a CT prior

Purpose: Pulmonary nodules present unique problems during radiation treatment due to nodule position uncertainty that is caused by respiration. The radiation field has to be enlarged to account for nodule motion during treatment. The purpose of this work is to provide a method of locating a pulmonary nodule in a megavolt portal image that can be used to reduce the internal target volume (ITV) during radiation therapy. A reduction in the ITV would result in a decrease in radiation toxicity to healthy tissue. Methods: Eight patients with nonsmall cell lung cancer were used in this study. CT scans that include the pulmonary nodule were captured with a GE Healthcare LightSpeed RT 16 scanner. Megavolt portal images were acquired with a Varian Trilogy unit equipped with an AS1000 electronic portal imaging device. The nodule localization method uses grayscale morphological filtering and level-set segmentation with a prior. The treatment-time portion of the algorithm is implemented on a graphical processing unit. Results: The method was retrospectively tested on eight cases that include a total of 151 megavolt portal image frames. The method reduced the nodule position uncertainty by an average of 40% for seven out of the eight cases. The treatment phase portion of the method has a subsecond execution time that makes it suitable for near-real-time nodule localization. Conclusions: A method was developed to localize a pulmonary nodule in a megavolt portal image. The method uses the characteristics of the nodule in a prior CT scan to enhance the nodule in the portal image and to identify the nodule region by level-set segmentation. In a retrospective study, the method reduced the nodule position uncertainty by an average of 40% for seven out of the eight cases studied.

60 APPLIED LIFE SCIENCES↗

Regularized iterative weighted filtered backprojection for helical cone-beam CT

Contemporary reconstruction methods employed for clinical helical cone-beam computed tomography (CT) are analytical (noniterative) but mathematically nonexact, i.e., the reconstructed image contains so called cone-beam artifacts, especially for higher cone angles. Besides cone artifacts, these methods also suffer from windmill artifacts: alternating dark and bright regions creating spiral-like patterns occurring in the vicinity of high z-direction derivatives. In this article, the authors examine the possibility to suppress cone and windmill artifacts by means of iterative application of nonexact three-dimensional filtered backprojection, where the analytical part of the reconstruction brings about accelerated convergence. Specifically, they base their investigations on the weighted filtered backprojection method [Stierstorfer et al., Phys. Med. Biol. 49, 2209-2218 (2004)]. Enhancement of high frequencies and amplification of noise is a common but unwanted side effect in many acceleration attempts. They have employed linear regularization to avoid these effects and to improve the convergence properties of the iterative scheme. Artifacts and noise, as well as spatial resolution in terms of modulation transfer functions and slice sensitivity profiles have been measured. The results show that for cone angles up to {+-}2.78 deg., cone artifacts are suppressed and windmill artifacts are alleviated within three iterations. Furthermore, regularization parameters controlling spatial resolution can be tuned so that image quality in terms of spatial resolution and noise is preserved. Simulations with higher number of iterations and long objects (exceeding the measured region) verify that the size of the reconstructible region is not reduced, and that the regularization greatly improves the convergence properties of the iterative scheme. Taking these results into account, and the possibilities to extend the proposed method with more accurate modeling of the acquisition process, the authors believe that iterative improvement with non-exact methods is a promising technique for medical CT applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Signal-to-noise assessment for diffusion tensor imaging with single data set and validation using a difference image method with data from a multicenter study

Purpose: To describe a quantitative method for determination of SNR that extracts the local noise level using a single diffusion data set. Methods: Brain data sets came from a multicenter study (eight sites; three MR vendors). Data acquisition protocol required b = 0, 700 s/mm{sup 2}, fov = 256 × 256 mm{sup 2}, acquisition matrix size 128 × 128, reconstruction matrix size 256 × 256; 30 gradient encoding directions and voxel size 2 × 2 × 2 mm{sup 3}. Regions-of-interest (ROI) were placed manually on the b = 0 image volume on transverse slices, and signal was recorded as the mean value of the ROI. The noise level from the ROI was evaluated using Fourier Transform based Butterworth high-pass filtering. Patients were divided into two groups, one for filter parameter optimization (N = 17) and one for validation (N = 10). Six white matter areas (the genu and splenium of corpus callosum, right and left centrum semiovale, right and left anterior corona radiata) were analyzed. The Bland–Altman method was used to compare the resulting SNR with that from the difference image method. The filter parameters were optimized for each brain area, and a set of “global” parameters was also obtained, which represent an average of all regions. Results: The Bland–Altman analysis on the validation group using “global” filter parameters revealed that the 95% limits of agreement of percent bias between the SNR obtained with the new and the reference methods were −15.5% (median of the lower limit, range [−24.1%, −8.9%]) and 14.5% (median of the higher limits, range [12.7%, 18.0%]) for the 6 brain areas. Conclusions: An FT-based high-pass filtering method can be used for local area SNR assessment using only one DTI data set. This method could be used to evaluate SNR for patient studies in a multicenter setting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Regularized deconvolution method for turbulent combustion modeling

The modeling of filtered chemical source terms in large-eddy simulation (LES) of turbulent reacting flows remains a challenge. Deconvolution methods are an attractive technique for representing these unclosed terms. With this technique, filtered scalars are reconstructed through deconvolution. The chemical source terms that are computed directly from the deconvolved scalars are filtered explicitly to represent the turbulence-chemistry interaction. However, the approximate deconvolution method (ADM), frequently employed for non-reacting flows, exhibits shortcomings for reacting scalars. This is because ADM does not ensure essential conservation and boundedness conditions. So to address this issue, we propose a regularized deconvolution method (RDM) based on an optimization procedure. We conduct a priori and a posteriori analyses to examine RDM as a closure in LES. These investigations are performed in the context of explicit filtering. By showing that RDM is accurate and stable with respect to both the filter width and time, we conclude that the new deconvolution method shows promise in application to combustion LES.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of Extended Kalman Filter Techniques for Dynamic Model Parameter Calibration

Abstract -Phasor measurement has previously been used for sub-system model validation, which enables rigorous comparison of model simulation and recorded dynamics and facilitates identification of problematic model components. Recent work extends the sub-system model validation approach with a focus on how model parameters may be calibrated to match recorded dynamics. In this paper, a calibration method using Extended Kalman Filter (EKF) technique is proposed. This paper presents the formulation as well as case studies to show the validity of the EKF-based parameter calibration method. The proposed calibration method is expected to be a cost-effective means complementary to traditional equipment testing for improving dynamic model quality.

Extended Kalman Filter↗

Modified Eigen-Decomposition-based Interval Analysis (MEDIA) for Power System Dynamic State Estimation

The Bayesian approach has been used for the dynamic state estimation (DSE) of a power system. However, due to the complexity of noise resources, it is difficult to quantify measurement and process noise using probability density functions (PDFs). To overcome the difficulty, the authors of this paper propose a modified eigen-decomposition-based interval analysis (MEDIA) method, which employs bounds instead of PDFs to quantify the noise, and uses the eigen decomposition method to reduce the negative impact of the overestimation problem. Using the simulation data generated from IEEE 16-machine and IEEE 10-machine systems, it is shown that the proposed MEDIA method can estimate the hard boundaries of dynamic states in real time. Furthermore, comparison with the forward-backward propagation method and the extended set-membership filter also shows that the proposed MEDIA method performs better by providing narrower boundaries in the DSE.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Feasibility of using intermediate x-ray energies for highly conformal extracranial radiotherapy

Purpose: To investigate the feasibility of using intermediate energy 2 MV x-rays for extracranial robotic intensity modulated radiation therapy. Methods: Two megavolts flattening filter free x-rays were simulated using the Monte Carlo code MCNP (v4c). A convolution/superposition dose calculation program was tuned to match the Monte Carlo calculation. The modeled 2 MV x-rays and actual 6 MV flattened x-rays from existing Varian Linacs were used in integrated beam orientation and fluence optimization for a head and neck, a liver, a lung, and a partial breast treatment. A column generation algorithm was used for the intensity modulation and beam orientation optimization. Identical optimization parameters were applied in three different planning modes for each site: 2, 6 MV, and dual energy 2/6 MV. Results: Excellent agreement was observed between the convolution/superposition and the Monte Carlo calculated percent depth dose profiles. For the patient plans, overall, the 2/6 MV x-ray plans had the best dosimetry followed by 2 MV only and 6 MV only plans. Between the two single energy plans, the PTV coverage was equivalent but 2 MV x-rays improved organs-at-risk sparing. For the head and neck case, the 2MV plan reduced lips, mandible, tongue, oral cavity, brain, larynx, left and right parotid gland mean doses by 14%, 8%, 4%, 14%, 24%, 6%, 30% and 16%, respectively. For the liver case, the 2 MV plan reduced the liver and body mean doses by 17% and 18%, respectively. For the lung case, lung V20, V10, and V5 were reduced by 13%, 25%, and 30%, respectively. V10 of heart with 2 MV plan was reduced by 59%. For the partial breast treatment, the 2 MV plan reduced the mean dose to the ipsilateral and contralateral lungs by 27% and 47%, respectively. The mean body dose was reduced by 16%. Conclusions: The authors showed the feasibility of using flattening filter free 2 MV x-rays for extracranial treatments as evidenced by equivalent or superior dosimetry compared to 6 MV plans using the same inverse noncoplanar intensity modulated planning method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-DE-207A-09: Low-Dose CT Image Reconstruction Via Learning From Different Patient Normal-Dose Images

Purpose: To investigate a novel low-dose CT (LdCT) image reconstruction strategy for lung CT imaging in radiation therapy. Methods: The proposed approach consists of four steps: (1) use the traditional filtered back-projection (FBP) method to reconstruct the LdCT image; (2) calculate structure similarity (SSIM) index between the FBP-reconstructed LdCT image and a set of normal-dose CT (NdCT) images, and select the NdCT image with the highest SSIM as the learning source; (3) segment the NdCT source image into lung and outside tissue regions via simple thresholding, and adopt multiple linear regression to learn high-order Markov random field (MRF) pattern for each tissue region in the NdCT source image; (4) segment the FBP-reconstructed LdCT image into lung and outside regions as well, and apply the learnt MRF prior in each tissue region for statistical iterative reconstruction of the LdCT image following the penalized weighted least squares (PWLS) framework. Quantitative evaluation of the reconstructed images was based on the signal-to-noise ratio (SNR), local binary pattern (LBP) and histogram of oriented gradients (HOG) metrics. Results: It was observed that lung and outside tissue regions have different MRF patterns predicted from the NdCT. Visual inspection showed that our method obviously outperformed the traditional FBP method. Comparing with the region-smoothing PWLS method, our method has, in average, 13% increase in SNR, 15% decrease in LBP difference, and 12% decrease in HOG difference from reference standard for all regions of interest, which indicated the superior performance of the proposed method in terms of image resolution and texture preservation. Conclusion: We proposed a novel LdCT image reconstruction method by learning similar image characteristics from a set of NdCT images, and the to-be-learnt NdCT image does not need to be scans from the same subject. This approach is particularly important for enhancing image quality in radiation therapy.

60 APPLIED LIFE SCIENCES↗

Long-term changes in the seasonality of Baltic sea level

The seasonal cycle accounts for about 40% of the total sea level variability in the Baltic Sea. In a climate change context, changes are expected to occur, not only in mean levels but also in the seasonal characteristics of sea level. The present study addresses the quantification of changes in the seasonal cycle of sea level from a set of century-long tide gauge records in the Baltic Sea. In order to obtain robust estimates of the changes in amplitude and phase of the seasonal cycle, we apply different methods, including continuous wavelet filtering, multi-resolution decomposition based on the maximal overlap discrete wavelet transform, auto-regressive-based decomposition, singular spectrum analysis and empirical mode decomposition. The results show that all methods generally trace a similar long-term variability of the annual cycle amplitudes, and we focus on discrete wavelet analysis as the natural counterpart of classical moving Fourier analysis. In contrast to previous studies suggesting the existence of long-term changes in the seasonal cycle, in particular an increase of the annual amplitude, we find alternating periods of high and low amplitudes without any clear indication of systematic long-term trends. The derived seasonal patterns are spatially coherent, discriminating the stations in the Baltic entrance from the remaining stations in the Baltic basin, for which zonal wind accounts for typically more than 40% of the variations in amplitude.

54 ENVIRONMENTAL SCIENCES↗

Coupling detergent lysis/clean-up methodology with intact protein fractionation for enhanced proteome characterization

The expanding use of surfactants for proteome sample preparations has prompted the need to systematically optimize the application and removal of these MS-deleterious agents prior to proteome measurements. Here we compare four different detergent clean-up methods (Trichloroacetic acid (TCA) precipitation, Chloroform/Methanol/Water (CMW) extraction, commercial detergent removal spin column method (DRS) and filter-aided sample preparation(FASP)) with respect to varying amounts of protein biomass in the samples, and provide efficiency benchmarks with respect to protein, peptide, and spectral identifications for each method. Our results show that for protein limited samples, FASP outperforms the other three clean-up methods, while at high protein amount all the methods are comparable. This information was used in a dual strategy of comparing molecular weight based fractionated and unfractionated lysates from three increasingly complex samples (Escherichia coli, a five microbial isolate mixture, and a natural microbial community groundwater sample), which were all lysed with SDS and cleaned up using FASP. The two approaches complemented each other by enhancing the number of protein identifications by 8%-25% across the three samples and provided broad pathway coverage.

FASP↗

Development of a testing method for asbestos fibers in treated materials of asbestos containing wastes by transmission electron microscopy

Highlights: • A high sensitive and selective testing method for asbestos in treated materials of asbestos containing wastes was developed. • Asbestos can be determined at a limits are a few million fibers per gram and a few μg g{sup −1}. • High temperature melting treatment samples were determined by this method. Asbestos fiber concentration were below the quantitation limit in all samples, and total fiber concentrations were determined as 47–170 × 10{sup 6} g{sup −1}. - Abstract: Appropriate treatment of asbestos-containing wastes is a significant problem. In Japan, the inertization of asbestos-containing wastes based on new treatment processes approved by the Minister of the Environment is promoted. A highly sensitive method for testing asbestos fibers in inertized materials is required so that these processes can be approved. We developed a method in which fibers from milled treated materials are extracted in water by shaking, and are counted and identified by transmission electron microscopy. Evaluation of this method by using asbestos standards and simulated slag samples confirmed that the quantitation limits are a few million fibers per gram and a few μg/g in a sample of 50 mg per filter. We used this method to assay asbestos fibers in slag samples produced by high-temperature melting of asbestos-containing wastes. Fiber concentrations were below the quantitation limit in all samples, and total fiber concentrations were determined as 47–170 × 10{sup −6} f/g. Because the evaluation of treated materials by TEM is difficult owing to the limited amount of sample observable, this testing method should be used in conjunction with bulk analytical methods for sure evaluation of treated materials.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of normalized metal artifact reduction (NMAR) in kVCT using MVCT prior images for radiotherapy treatment planning

Purpose: To evaluate the metal artifacts in kilovoltage computed tomography (kVCT) images that are corrected using a normalized metal artifact reduction (NMAR) method with megavoltage CT (MVCT) prior images.Methods: Tissue characterization phantoms containing bilateral steel inserts are used in all experiments. Two MVCT images, one without any metal artifact corrections and the other corrected using a modified iterative maximum likelihood polychromatic algorithm for CT (IMPACT) are translated to pseudo-kVCT images. These are then used as prior images without tissue classification in an NMAR technique for correcting the experimental kVCT image. The IMPACT method in MVCT included an additional model for the pair/triplet production process and the energy dependent response of the MVCT detectors. An experimental kVCT image, without the metal inserts and reconstructed using the filtered back projection (FBP) method, is artificially patched with the known steel inserts to get a reference image. The regular NMAR image containing the steel inserts that uses tissue classified kVCT prior and the NMAR images reconstructed using MVCT priors are compared with the reference image for metal artifact reduction. The Eclipse treatment planning system is used to calculate radiotherapy dose distributions on the corrected images and on the reference image using the Anisotropic Analytical Algorithm with 6 MV parallel opposed 5 × 10 cm{sup 2} fields passing through the bilateral steel inserts, and the results are compared. Gafchromic film is used to measure the actual dose delivered in a plane perpendicular to the beams at the isocenter.Results: The streaking and shading in the NMAR image using tissue classifications are significantly reduced. However, the structures, including metal, are deformed. Some uniform regions appear to have eroded from one side. There is a large variation of attenuation values inside the metal inserts. Similar results are seen in commercially corrected image. Use of MVCT prior images without tissue classification in NMAR significantly reduces these problems. The radiation dose calculated on the reference image is close to the dose measured using the film. Compared to the reference image, the calculated dose difference in the conventional NMAR image, the corrected images using uncorrected MVCT image, and IMPACT corrected MVCT image as priors is ∼15.5%, ∼5%, and ∼2.7%, respectively, at the isocenter.Conclusions: The deformation and erosion of the structures present in regular NMAR corrected images can be largely reduced by using MVCT priors without tissue segmentation. The attenuation value of metal being incorrect, large dose differences relative to the true value can result when using the conventional NMAR image. This difference can be significantly reduced if MVCT images are used as priors. Reduced tissue deformation, better tissue visualization, and correct information about the electron density of the tissues and metals in the artifact corrected images could help delineate the structures better, as well as calculate radiation dose more correctly, thus enhancing the quality of the radiotherapy treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anisotropic Total Variation Filtering

Total variation regularization and anisotropic filtering have been established as standard methods for image denoising because of their ability to detect and keep prominent edges in the data. Both methods, however, introduce artifacts: In the case of anisotropic filtering, the preservation of edges comes at the cost of the creation of additional structures out of noise; total variation regularization, on the other hand, suffers from the stair-casing effect, which leads to gradual contrast changes in homogeneous objects, especially near curved edges and corners. In order to circumvent these drawbacks, we propose to combine the two regularization techniques. To that end we replace the isotropic TV semi-norm by an anisotropic term that mirrors the directional structure of either the noisy original data or the smoothed image. We provide a detailed existence theory for our regularization method by using the concept of relaxation. The numerical examples concluding the paper show that the proposed introduction of an anisotropy to TV regularization indeed leads to improved denoising: the stair-casing effect is reduced while at the same time the creation of artifacts is suppressed.

97 MATHEMATICS AND COMPUTING↗

Measuring the Interestingness of Articles in a Limited User Environment

Search engines, such as Google, assign scores to news articles based on their relevancy to a query. However, not all relevant articles for the query may be interesting to a user. For example, if the article is old or yields little new information, the article would be uninteresting. Relevancy scores do not take into account what makes an article interesting, which varies from user to user. Although methods such as collaborative filtering have been shown to be effective in recommendation systems, in a limited user environment, there are not enough users that would make collaborative filtering effective. A general framework, called iScore, is presented for defining and measuring the 'interestingness' of articles, incorporating user-feedback. iScore addresses various aspects of what makes an article interesting, such as topic relevancy, uniqueness, freshness, source reputation, and writing style. It employs various methods to measure these features and uses a classifier operating on these features to recommend articles. The basic iScore configuration is shown to improve recommendation results by as much as 20%. In addition to the basic iScore features, additional features are presented to address the deficiencies of existing feature extractors, such as one that tracks multiple topics, called MTT, and a version of the Rocchio algorithm that learns its parameters online as it processes documents, called eRocchio. The inclusion of both MTT and eRocchio into iScore is shown to improve iScore recommendation results by as much as 3.1% and 5.6%, respectively. Additionally, in TREC11 Adaptive Filter Task, eRocchio is shown to be 10% better than the best filter in the last run of the task. In addition to these two major topic relevancy measures, other features are also introduced that employ language models, phrases, clustering, and changes in topics to improve recommendation results. These additional features are shown to improve recommendation results by iScore by up to 14%. Due to varying reasons that users hold regarding why an article is interesting, an online feature selection method in naive Bayes is also introduced. Online feature selection can improve recommendation results in iScore by up to 18.9%. In summary, iScore in its best configuration can outperform traditional IR techniques by as much as 50.7%. iScore and its components are evaluated in the news recommendation task using three datasets from Yahoo! News, actual users, and Digg. iScore and its components are also evaluated in the TREC Adaptive Filter task using the Reuters RCV1 corpus.

99 GENERAL AND MISCELLANEOUS↗