Search NASA⌕ Search

SEARCH · Search NASA

Results for “fluorescent imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Subcellular targeting of nine calcium-dependent protein kinase isoforms from Arabidopsis

Calcium-dependent protein kinases (CDPKs) are specific to plants and some protists. Their activation by calcium makes them important switches for the transduction of intracellular calcium signals. Here, we identify the subcellular targeting potentials for nine CDPK isoforms from Arabidopsis, as determined by expression of green fluorescent protein (GFP) fusions in transgenic plants. Subcellular locations were determined by fluorescence microscopy in cells near the root tip. Isoforms AtCPK3-GFP and AtCPK4-GFP showed a nuclear and cytosolic distribution similar to that of free GFP. Membrane fractionation experiments confirmed that these isoforms were primarily soluble. A membrane association was observed for AtCPKs 1, 7, 8, 9, 16, 21, and 28, based on imaging and membrane fractionation experiments. This correlates with the presence of potential N-terminal acylation sites, consistent with acylation as an important factor in membrane association. All but one of the membrane-associated isoforms targeted exclusively to the plasma membrane. The exception was AtCPK1-GFP, which targeted to peroxisomes, as determined by covisualization with a peroxisome marker. Peroxisome targeting of AtCPK1-GFP was disrupted by a deletion of two potential N-terminal acylation sites. The observation of a peroxisome-located CDPK suggests a mechanism for calcium regulation of peroxisomal functions involved in oxidative stress and lipid metabolism.

Non-NASA Center↗

Identifying Indicators of Harmful Algal Blooms in Coastal Atacama Using Satellite Image Processing Techniques to Improve Industry and Authority Response

Over the past decade, Chile has experienced a significant rise in both the frequency and intensity of coastal Harmful Algal Blooms (HABs). These bloom events are a growing concern for the Atacama Region especially, with potential impacts on human health, aquaculture, and the environment. HABs are caused by an excess proliferation of microalgae, with certain algae species commonly found in Chilean HABs capable of producing toxins which can poison fish, toxify shellfish, and cause illness or death when ingested by humans. Collaborating with the Ministry of Health of Chile, Centro de Información de Recursos Naturales, the University of Atacama, and the Embassy of Chile’s Agricultural Office, this study identifies potential indicators of HABs in the Coastal Atacama Region using NASA Earth observations. Satellite imagery from the Moderate Resolution Imaging Spectroradiometer (MODIS) instrument onboard NASA’s Aqua satellite was used for the identification of chlorophyll-a which provides direct estimates of the algae pigment’s concentration in water bodies. In addition, the spatiotemporal patterns of several other parameters were examined to identify correlations with occurrences of HABs, including sea surface temperature and normalized fluorescence line height using Aqua MODIS, Normalized Difference Turbidity Index (NDTI) using Landsat 8, and ocean wind speed measurements from the NOAA Joint Polar Satellite System. Analysis of these patterns revealed hotspots of high chlorophyll-a concentrations from the years 2014 to 2022, the most major of which occurring in the coastal zones of Chañaral, Bahía Inglesa, and Huasco. Also, through the use of a similarity search conducted, the seasonal variation of these indicators was mapped to highlight areas with great likelihood of experiencing HABs in the future. The results can guide future efforts for in-situ water sampling, toxin analysis and assessment, and HAB monitoring and prevention.

Cody O'Ferrall↗

X-Ray Fluorescence Solvent Detection at the Substrate-Adhesive Interface

With environmental regulations limiting the use of volatile organic compounds, low-vapor pressure solvents have replaced traditional degreasing solvents for bond substrate preparation. When used to clean and prepare porous bond substrates such as phenolic composites, low vapor pressure solvents can penetrate deep into substrate pore networks and remain there for extended periods. Trapped solvents can interact with applied adhesives either prior to or during cure, potentially compromising bond properties. Currently, methods for characterizing solvent time-depth profiles in bond substrates are limited to bulk gravimetric or sectioning techniques. While sectioning techniques such as microtome allow construction of solvent depth profiles, their depth resolution and reliability are limited by substrate type. Sectioning techniques are particularly limited near the adhesive-substrate interface where depth resolution is further limited by adhesive-substrate hardness and, in the case of a partially cured adhesive, mechanical properties differences. Additionally, sectioning techniques cannot provide information about lateral solvent diffusion. Cross-section component mapping is an alternative method for measuring solvent migration in porous substrates that eliminates the issues associated with sectioning techniques. With cross-section mapping, the solvent-wiped substrate is sectioned perpendicular rather than parallel to the wiped surface, and the sectioned surface is analyzed for the solvent or solvent components of interest using a two-dimensional mapping or imaging technique. Solvent mapping can be performed using either direct or indirect methods. With a direct method, one or more solvent components are mapped using red or Raman spectroscopy together with a moveable sample stage and/or focal plane array detector. With an indirect method, an elemental "tag" not present in the substrate is added to the solvent before the substrate is wiped. Following cross sectioning, the tag element can then be mapped by its characteristic x-ray emission using either x-ray fluorescence, or electron-beam energy-and wavelength-dispersive x-ray spectrometry. The direct mapping techniques avoid issues of different diffusion or migration rates of solvents and elemental tags, while the indirect techniques avoid spectral resolution issues in cases where solvents and substrates have adjacent or overlapping peaks. In this study, cross-section component indirect mapping is being evaluated as a method for measuring migration of d-limonene based solvents in glass-cloth phenolic composite (GCP) prior to and during subsequent bonding and epoxy adhesive cure.

Wurth, Laura↗

OH Planar Laser Induced Fluorescence (PLIF) Measurements for the Study of High Pressure Flames: An Evaluation of a New Laser and a New Camera System

Planar laser induced fluorescence (PLIF) is used by the Combustion Branch at the NASA Glenn Research Center (NASA Glenn) to assess the characteristics of the flowfield produced by aircraft fuel injectors. To improve and expand the capabilities of the PLIF system new equipment was installed. The new capabilities of the modified PLIF system are assessed by collecting OH PLIF in a methane/air flame produced by a flat flame burner. Specifically, the modifications characterized are the addition of an injection seeder to a Nd:YAG laser pumping an optical parametric oscillator (OPO) and the use of a new camera with an interline CCD. OH fluorescence results using the injection seeded OPO laser are compared to results using a Nd:YAG pumped dye laser with ultraviolet extender (UVX). Best settings of the new camera for maximum detection of PLIF signal are reported for the controller gain and microchannel plate (MCP) bracket pulsing. Results are also reported from tests of the Dual Image Feature (DIF) mode of the new camera which allows image pairs to be acquired in rapid succession. This allows acquisition of a PLIF image and a background signal almost simultaneously. Saturation effects in the new camera were also investigated and are reported.

Tedder, Sarah↗

Development of Radioluminescent Tritium Polymeric Material for High Visibility Applications

The Development of Radioluminescent Tritium Polymeric Material for High Visibility Applications effort investigates the nature and properties of materials consisting of tritium lights combined with various silicone adhesives. Physical, mechanical, and optical properties will be observed/measured, including their durability in the low earth orbit environment. Tritium or hydrogen-three is a radioactive isotope of hydrogen that emits beta particles as it undergoes a process called beta decay. A beta particle is a high-energy, high-speed electron (or positron) emitted from radioactive decay of an atomic nucleus. Because it is a gas, tritium must be bound to a material or encapsulated in a sealed glass container. The gaseous tritium can then be combined with a phosphor source which when struck with beta particles, fluoresces and emits light. Such a light source is referred to as a gaseous tritium light source (GTLS). A self-powered, radioluminescent tritium material capable of surviving multiple space environments has the potential to fulfill visibility requirements levied on space flight hardware and facilitate additional long term internal and external lighting needs such as for imaging, docking, tracking, and xEMU suits for lunar exploration on the moon.

Lauren Fisher↗

Optical Measurement and Visualization in High-Pressure, High-Temperature, Aviation Gas Turbine Combustors

Planar laser-induced fluorescence (PLIF), planar Mie scattering (PMie), and linear (1-D) spontaneous Raman scattering are applied to flame tube and sector combustors that burn Jet-A fuel at a range of inlet temperatures and pressures that simulate conditions expected in future high-performance civilian gas turbine engines. Chemiluminescence arising from C2 in the flame was also imaged. Flame spectral emissions measurements were obtained using a scanning spectrometer. Several different advanced concept fuel injectors were examined. First-ever PLIF and chemiluminescence data are presented from the 60-atm Gas turbine combustor facility.

Hicks, Yolanda R.↗

Design of a Borescope for Extravehicular Non-Destructive Applications

Anomalies such as corrosion, structural damage, misalignment, cracking, stress fiactures, pitting, or wear can be detected and monitored by the aid of a borescope. A borescope requires a source of light for proper operation. Today s current lighting technology market consists of incandescent lamps, fluorescent lamps and other types of electric arc and electric discharge vapor lamp. Recent advances in LED technology have made LEDs viable for a number of applications, including vehicle stoplights, traffic lights, machine-vision-inspection, illumination, and street signs. LEDs promise significant reduction in power consumption compared to other sources of light. This project focused on comparing images taken by the Olympus IPLEX, using two different light sources. One of the sources is the 50-W internal metal halide lamp and the other is a 1 W LED placed at the tip of the insertion tube. Images acquired using these two light sources were quantitatively compared using their histogram, intensity profile along a line segment, and edge detection. Also, images were qualitatively compared using image registration and transformation [l]. The gray-level histogram, edge detection, image profile and image registration do not offer conclusive results. The LED light source, however, produces good images for visual inspection by an operator. Analysis using pattern recognition using Eigenfaces and Gaussian Pyramid in face recognition may be more useful.

Bachnak, Rafic↗

Ultraviolet spectra of HH 1 and HH 2 - Spatial variations and the continuum problem

High-SNR 12-hr and 14-hr ultraviolet spectra of HH 1 and HH2 in the IUE short-wavelength range are reported. HH 1 data show a (spatial) half-width of the image size in the C IV 1548-A, 1551-A line which is smaller than the spatial half-width for the semiforbidden C II 1907-A, 1909-A line. A qualitatively similar situation is shown for HH 2, although differences in the image sizes are smaller than for HH 1. The continua of HH 1 and HH2 are found to have a relatively similar wavelength dependence, even in rather small features, and to both have their maxima between 1570 and 1580 A. It is noted that the observed wavelength of the continuum maximum agrees with the position of the maximum of the H2 fluorescence spectrum.

Boehm, K. H.↗

Multiple dataset water-quality analyses in the vicinity of an ocean wastewater plume

The White's Point ocean outfall is the method of disposal for approximately 374 million gallons of treated wastewater per day from Los Angeles County. The photosynthetic characteristics and particle distributions have well-defined properties that can be exploited to yield information on transport of the plume, mixing dynamics, and resuspension of bottom sediments during periods of bottom current velocity in excess of ca. 0.1 m/s. This plume of particles serves as a conservative tracer, which was studied using a number of sampling platforms and strategies, including underway sawtooth, or 'tow-yo' sampling, moored arrays of instruments, stationary profiling, and now for the first time with remotely-sensed multispectral color imagery. Research in this area previously focused on examination of the plume as it relates to the local current field and transport of particles, and on the resuspension of bottom sediments during periods of increased currents. In addition, Wu et al elucidated techniques for separating the particle signal into photosynthetic and nonphotosynthetic components, based on the beam attenuation to chlorophyll fluorescence ratio. High-frequency time series measurements of the current field and bio-optical characteristics at a site close to the waste diffusers were also collected. These are being analyzed for the spectral characteristics of the longer-timescale variability, in order to predict particle transport through simple meteorological measurements. With the advent of high spectral and spatial resolution imaging spectrometers such as AVIRIS, it is now possible to construct causal relationships between particle distributions and signature of the upwelled radiance from the surface. The availability of a constant and well-characterized source of material lends itself well to models which predict upwelled radiance from the surface. The availability of a constant and well-characterized source of material lends itself well to models which predict upwelled light as a function of particle distributions, photosynthetic pigments, colored dissolved organic material, and detrital and degradation products of photosynthesis. In addition, the spatial coverage provided by the tow-yo sampling device, combined with the profile measurements of the light field, should facilitate the best inverse modeling attempts possible thus far.

Hamilton, Michael↗

Cytometer on a Chip

A cytometer now under development exploits spatial sorting of sampled cells on a microarray chip followed by use of grating-coupled surface-plasmon-resonance imaging (GCSPRI) to detect the sorted cells. This cytometer on a chip is a prototype of contemplated future miniature cytometers that would be suitable for rapidly identifying pathogens and other cells of interest in both field and laboratory applications and that would be attractive as alternatives to conventional flow cytometers. The basic principle of operation of a conventional flow cytometer requires fluorescent labeling of sampled cells, stringent optical alignment of a laser beam with a narrow orifice, and flow of the cells through the orifice, which is subject to clogging. In contrast, the principle of operation of the present cytometer on a chip does not require fluorescent labeling of cells, stringent optical alignment, or flow through a narrow orifice. The basic principle of operation of the cytometer on a chip also reduces the complexity, mass, and power of the associated laser and detection systems, relative to those needed in conventional flow cytometry. Instead of making cells flow in single file through a narrow flow orifice for sequential interrogation as in conventional flow cytometry, a liquid containing suspended sampled cells is made to flow over the front surface of a microarray chip on which there are many capture spots. Each capture spot is coated with a thin (.50-nm) layer of gold that is, in turn, coated with antibodies that bind to cell-surface molecules characteristic of the cell species of interest. The multiplicity of capture spots makes it possible to perform rapid, massively parallel analysis of a large cell population. The binding of cells to each capture spot gives rise to a minute change in the index of refraction at the surface of the chip. This change in the index of refraction is what is sensed in GCSPRI, as described briefly below. The identities of the various species in a sample of cells is spatially encoded in the chip by the pattern of capture spots. The number of cells of a particular species is determined from the magnitude of the GCSPRI signal from that spot. GCSPRI as used here can be summarized as follows: The cytometer chip is fabricated with a diffraction grating on its front surface. The chip is illuminated with a light emitting diode (LED) from the front. By proper choice of grating parameters and of the wavelength and the angle of incidence of a laser beam, laser light can be made to be coupled into an electromagnetic mode that resonates with surface plasmons and thus couples light into surface plasmons. Coupling of light into a surface plasmon at a given location reduces the amount of incident light reflected from that location. A change in the index of refraction at the surface of a capture spot gives rise to a change in the resonance condition. Depending on the specific design, the change in the index of refraction could manifest itself as a brightening or darkening, a change in the wavelength needed to excite the plasmon at a given angle of incidence, or a change in the angle of incidence needed to excite the plasmon at a given wavelength. Whereas a multiwavelength laser system with multichannel detection would be needed to detect multiple species in conventional flow cytometry, it suffices to use an LED and a single detector channel in the GCSPRI approach: this contributes significantly to reductions in cost, complexity, size, mass, and power. GCSPRI cytometer chips could be made of plastic and could be mass-produced cheaply by use of molding and other methods adopted from the manufacture of digital video disks. These methods are amenable to a high degree of miniaturization: such additional features as fluidic channels, reaction chambers, and fluid-coupling ports could readily be incorporated into the chips, without incurring substantial additional costs.

Fernandez, Salvador M.↗

Cytometer on a Chip

A cytometer now under development exploits spatial sorting of sampled cells on a microarray chip followed by use of grating-coupled surface-plasmon-resonance imaging (GCSPRI) to detect the sorted cells. This cytometer on a chip is a prototype of contemplated future miniature cytometers that would be suitable for rapidly identifying pathogens and other cells of interest in both field and laboratory applications and that would be attractive as alternatives to conventional flow cytometers. The basic principle of operation of a conventional flow cytometer requires fluorescent labeling of sampled cells, stringent optical alignment of a laser beam with a narrow orifice, and flow of the cells through the orifice, which is subject to clogging. In contrast, the principle of operation of the present cytometer on a chip does not require fluorescent labeling of cells, stringent optical alignment, or flow through a narrow orifice. The basic principle of operation of the cytometer on a chip also reduces the complexity, mass, and power of the associated laser and detection systems, relative to those needed in conventional flow cytometry. Instead of making cells flow in single file through a narrow flow orifice for sequential interrogation as in conventional flow cytometry, a liquid containing suspended sampled cells is made to flow over the front surface of a microarray chip on which there are many capture spots. Each capture spot is coated with a thin (approximately 50-nm) layer of gold that is, in turn, coated with antibodies that bind to cell-surface molecules characteristic of one the cell species of interest. The multiplicity of capture spots makes it possible to perform rapid, massively parallel analysis of a large cell population. The binding of cells to each capture spot gives rise to a minute change in the index of refraction at the surface of the chip. This change in the index of refraction is what is sensed in GCSPRI, as described briefly below. The identities of the various species in a sample of cells is spatially encoded in the chip by the pattern of capture spots. The number of cells of a particular species is determined from the magnitude of the GCSPRI signal from that spot. GCSPRI as used here can be summarized as follows: The cytometer chip is fabricated with a diffraction grating on its front surface. The chip is illuminated with a light emitting diode (LED) from the front. By proper choice of grating parameters and of the wavelength and the angle of incidence of a laser beam, laser light can be made to be coupled into an electromagnetic mode that resonates with surface plasmons and thus couples light into surface plasmons. Coupling of light into a surface plasmon at a given location reduces the amount of incident light reflected from that location. A change in the index of refraction at the surface of a capture spot gives rise to a change in the resonance condition. Depending on the specific design, the change in the index of refraction could manifest itself as a brightening or darkening, a change in the wavelength needed to excite the plasmon at a given angle of incidence, or a change in the angle of incidence needed to excite the plasmon at a given wavelength. Whereas a multiwavelength laser system with multichannel detection would be needed to detect multiple species in conventional flow cytometry, it suffices to use an LED and a single detector channel in the GCSPRI approach: this contributes significantly to reductions in cost, complexity, size, mass, and power. GCSPRI cytometer chips could be made of plastic and could be mass-produced cheaply by use of molding and other methods adopted from the manufacture of digital video disks. These methods are amenable to a high degree of miniaturization: such additional features as fluidic channels, reaction chambers, and fluid-coupling ports could readily be incorporated into the chips, without incurring substantial additional costs.

Fernandez, Salvador M.↗

Shear Stress Sensing with Elastic Microfence Structures

In this work, elastic microfences were generated for the purpose of measuring shear forces acting on a wind tunnel model. The microfences were fabricated in a two part process involving laser ablation patterning to generate a template in a polymer film followed by soft lithography with a two-part silicone. Incorporation of a fluorescent dye was demonstrated as a method to enhance contrast between the sensing elements and the substrate. Sensing elements consisted of multiple microfences prepared at different orientations to enable determination of both shear force and directionality. Microfence arrays were integrated into an optical microscope with sub-micrometer resolution. Initial experiments were conducted on a flat plate wind tunnel model. Both image stabilization algorithms and digital image correlation were utilized to determine the amount of fence deflection as a result of airflow. Initial free jet experiments indicated that the microfences could be readily displaced and this displacement was recorded through the microscope.

Cisotto, Alexxandra↗

Determination of Chlorophyll Content in Selected Grass Communities of Krkonoše Mts. Tundra Based on Laboratory Spectroscopy and Aerial Hyperspectral Data

The study focuses on the determination of chlorophyll content in four prevailing grasses in the relict arctic-alpine tundra located in the Krkonoše Mountains National Park, Czech Republic. We compared two methods for determination of leaf chlorophyll content (LCC) – spectrophotometric determination in the laboratory, and the LCC assessed by fluorescence portable chlorophyll meter CCM-300. Relationships were established between the LCCs and vegetation indices calculated from leaf spectra acquired with contact probe coupled with an ASD FieldSpec4 Wide-Res spectroradiometer. Canopy chlorophyll contents (CCC) were computed from the LCCs and green leaf area index (LAI), and modelled based on the field spectra measured by the spectroradiometer and the hyperspectral images acquired by Headwall Nano-Hyperspec® mounted on the DJI Matrice 600 Pro drone. The calculations are performed on datasets acquired in June, July and August 2020 together and separately for species and months. In general, the correlations based on June datasets work the best at both levels: median R 2 for all indices was 0.52 for all species together at leaf level and median R 2 = 0.47 at the canopy level (vegetation indices computed from field spectra). Canopy chlorophyll content map was created based on the results of stepwise multiple linear regression. The R 2 was 0.42 when using four wavelengths from the red and red edge spectral region. We attribute the weak model performance to a combination of several factors: leaf structure may bias LCC from laboratory measurements, effects of LAI variability on CCC, and the sampling design, probably not covering the whole phenology equally for all studied species.

L. Cervena↗

Free-surface phenomena under low- and zero-gravity conditions

A free surface experiment using a liquid doped with a fluorescent dye under sheet illumination is summarized. The work includes the selection of a CCD camera for use during the design stages of the experiment as well as a preliminary demonstration of this technique in the production of a contour map of a liquid-liquid interface with better than 0.1 mm resolution. With a different data sampling and storage procedure, the image processing is reduced to a simple thresholding procedure which can be done in hardware.

Hesselink, L.↗

The comet rendezvous asteroid flyby mission

The Comet Rendezvous Asteroid Flyby Mission (CRAF) is described. After gravity assists from Venus and Earth, the spacecraft will fly by the asteroid 46 Hestia en route to a rendezvous with P/Tempel 2 in Nov. 1996, when the comet is near aphelion. The scientific experiments for the CRAF mission are: an imaging system; a visual and infrared mapping spectrometer; an infrared radiometer; a penetrator carrying a gamma-ray spectrometer, a scanning differential calorimeter and evolved gas analyzer, accelerometers, and temperature probes; a neutral gas and thermal ion mass spectrometer; a secondary ion mass spectrometer for analyzing dust, gas, and thermal ions; a scanning electron microscope and particle analyzer; an X-ray fluorescence and gas chromatographic analyzer for collected dust and ice samples; a dust counter and velocity analyzer; a retarding potential ion mass spectrometer; a supra-thermal ion mass spectrometer and electron analyzer; a magnetometer; and a coordinated radio, electron, and plasma wave analyzer.

Neugebauer, M.↗

Biosensors for Real-Time Monitoring of Radiation-Induced Biologic Effects in Space

This proposal seeks to develop cellular biosensors based on dendritic polymers. Nanoscale polymer structures less than 20 nm in diameter will be used as the basis of the sensor/actuators. The structures will be designed to target into specific cells of an astronaut and be able to monitor health issues such as the exposure to radiation or infectious agents. Multiple components can be assembled on the polymers including target directors, analytical devices (such as molecular probes), magnetic particles and metals, and imaging agents. The design and assembly of these devices has been pioneered at the Center for Biologic Nanotechnology in the University of Michigan. These molecules would also be able to administer therapeutics in response to the needs of the astronaut, and act as actuators to remotely manipulate an astronaut as necessary to ensure their safety. The reporting will be accomplished either through fluorescence signal monitoring, with the use of multispectral analysis for signal interpretation, or through functional MRI. These nanosensors coupled to NEMS devices could facilitate the success and increase the safety of extended space flight.

Baker, James R., Jr.↗

Mapping the Moon in Soft x Rays: Promises and Challenges

Recent ROSAT images reported by Schmitt et el. show that the sunlit part of the Moon is a significant source of very soft x rays. Stimulated by these observations, Edwards et al. have made an analysis of the response of the Moon to the solar soft x ray and EUV spectrum. They argue that much of the observed emission is in the form of discrete fluorescence lines in the energy range 25 to 100 eV, and that these lines are generally much stronger than the adjacent directly scattered solar background. On this basis they suggest that soft x ray fluorescence can be used to remotely obtain high-precision elemental maps of the lunar surface. Edwards et al. have continued to develop this idea and have suggested a system using soft x ray telescopes in lunar orbit, which could also obtain very good spatial resolution. This combination could be extremely valuable in furthering our understanding of lunar chemistry and potential resource distributions. High spatial resolution combined with the thin surface layer from which these soft x rays arise suggests the exciting possibility that x ray telescopes could map lunar volcanic volatiles from orbit.

Housley, R. M.↗

Scalar mixing in the supersonic shear layer

Experiments were conducted in a two-stream planar mixing layer facility at convective Mach numbers of 0.28 and 0.62. Mie scattering from condensed alcohol droplets and planar laser-induced fluorescence (PLIF) of nitric oxide were used for flow visualization in both the side and plan views. The PLIF signals were approximately proportional to mixture fraction and were used to generate statistical quantities. Visualizations using both the Mie scattering and PLIF indicate the structure is essentially two-dimensional at Mc = 0.28 and three-dimensional at Mc = 0.62. Perspective renderings of side view images show the structures are streamwise ramped at Mc = 0.28 and cross-stream ramped at Mc = 0.62. This difference appears to be associated with decreasing streamwise structure spacings at the higher Mc condition. The statistical analysis suggests that with increasing compressibility, the scalar fluctuations are smaller, and the fraction of mixed fluid is higher.

Clemens, N. T.↗