Search NASA⌕ Search

SEARCH · Search NASA

Results for “functional testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

An antenna pointing mechanism for large reflector antennas

An antenna pointing mechanism for large reflector antennas on direct broadcasting communication satellites was built and tested. After listing the requirements and constraints for this equipment the model is described, and performance figures are given. Futhermore, results of the qualification level tests, including functional, vibrational, thermovacuum, and accelerated life tests are reported. These tests were completed successfully.

Heimerdinger, H.↗

Characterization of elastomeric materials with application to design

Redesign of the Space Shuttle Solid Booster has necessitated re-evaluation of the material used in the field joint O-ring seals. The viscoelastic characteristics of five candidate materials were determined. The five materials are: two fluorocarbon compounds, two nitrile compounds, and a silicon compound. The materials were tested in a uniaxial compression test to determine the characteristic relaxation functions. These tests were performed at five different temperatures. A master material curve was developed for each material from the experimental data. The results are compared to tensile relaxation tests. Application of these results to the design analysis is discussed in detail.

Bower, Mark V.↗

Viscoelastic properties of elastomeric materials for O-ring applications

Redesign of the Space Shuttle Solid Rocket Booster necessitated re-evaluation of the material used in the field joint O-ring seals. This research project was established to determine the viscoelastic characteristics of five candidate materials. The five materials are: two fluorocarbon compounds, two nitrile compounds, and a silicon compound. The materials were tested in a uniaxial compression test to determine the characteristic relaxation functions. These tests were performed at five different temperatures. A master material curve was developed for each material from the experimental data. The results of this study are compared to tensile relaxation tests. Application of these results to the design analysis is discussed in detail.

Bower, Mark V.↗

Efficient Evaluation and Optimization of Structural Reliability

Use of approximations for calculating the structural failure probability under uncertainties is a necessary aspect. But efficient use of suitable approximations at different stages of reliability prediction and design makes this valuable tool practical for many large scale structures. This research addresses the modern approximation concepts and their utility in structural reliability estimation. Emphasis is placed on building higher order approximations using intervening variables to closely represent the nonlinear limit state functions. Several test problems with highly nonlinear performance functions are used to demonstrate the accuracy of the proposed method. Many of the structural problems are modeled and simulated using the finite element methods (FEM) for obtaining a detailed structural response. FEM is a computationally intensive numerical procedure with a large number of degrees of freedom. With an increase in the complexity of the structural model and the multidisciplinary nature of analyses, the number of limit states and their computation increases very significantly. The requirement of frequent repetitive analysis of the structure hinders the utility of any tool and discourages that approach from being used. One particular tool which faces this difficulty is the computation of the structural reliability under parametric uncertainties.

Grandhi, Ramana V.↗

Evaluating the Relationships Between Supine Propriorception Assessments With Upright Functional Mobility and Balance Tests

- Sensorimotor adaptations during spaceflight can result in impaired posture and locomotion upon return to Earth. - In-flight sensorimotor countermeasures and assessment tools are needed to mitigate risks associated with mission-critical task performance upon return to Earth or arrival to Mars. - The tilt board (Fig. 1) is proposed as an inflight proprioceptive countermeasure and will be tested in an upcoming bed rest study. - Proprioceptive assessments on the tilt board may also help predict post-flight and post-bedrest functional task performance.

Rachel F. Bellisle↗

Combining high performance simulation, data acquisition, and graphics display computers

Issues involved in the continuing development of an advanced simulation complex are discussed. This approach provides the capability to perform the majority of tests on advanced systems, non-destructively. The controlled test environments can be replicated to examine the response of the systems under test to alternative treatments of the system control design, or test the function and qualification of specific hardware. Field tests verify that the elements simulated in the laboratories are sufficient. The digital computer is hosted by a Digital Equipment Corp. MicroVAX computer with an Aptec Computer Systems Model 24 I/O computer performing the communication function. An Applied Dynamics International AD100 performs the high speed simulation computing and an Evans and Sutherland PS350 performs on-line graphics display. A Scientific Computer Systems SCS40 acts as a high performance FORTRAN program processor to support the complex, by generating numerous large files from programs coded in FORTRAN that are required for the real time processing. Four programming languages are involved in the process, FORTRAN, ADSIM, ADRIO, and STAPLE. FORTRAN is employed on the MicroVAX host to initialize and terminate the simulation runs on the system. The generation of the data files on the SCS40 also is performed with FORTRAN programs. ADSIM and ADIRO are used to program the processing elements of the AD100 and its IOCP processor. STAPLE is used to program the Aptec DIP and DIA processors.

Hickman, Robert J.↗

Portable Software Environment for Ultrahigh-Resolution ELM Development on GPUs

This paper presents our endeavors in developing the large-scale, ultra-high-resolution E3SM Land Model (uELM), specifically designed for exascale computers furnished with accelerators such as Nvidia GPUs. The uELM is a sophisticated code that substantially relies on High-Performance Computing (HPC) environments, necessitating particular machine and software configurations. To facilitate community-based uELM developments employing GPUs, we have created a portable, standalone software environment preconfigured with uELM input datasets, simulation cases, and source code. This environment, utilizing Docker, encompasses all essential code, libraries, and system software for uELM development on GPUs. It also features a functional unit test framework and an offline model testbed for comprehensive numerical experiments. From a technical perspective, the paper discusses GPU-ready container generations, uELM code management, and input data distribution across computational platforms. Lastly, the paper demonstrates the use of environment for functional unit testing, end-to-end simulation on CPUs and GPUs, and collaborative code development.

E3SM Land Model↗

Development and Testing of Cooled CMCs for High Thermal Flux Applications

Ceramic Matrix Composites (CMCS) offer the potential for significant weight savings and improved performance for a range of propulsion components utilizing refractory materials. This paper describes the fabrication and testing of functionally graded CMCs produced via a low cost process that represents an order of magnitude cost savings over conventionally fabricated CMCS. Test cylinders were fabricated, characterized and evaluated during exposure to high thermal fluxes of up to 10MW/meters squared at the Laser Hardened Materials Evaluation Laboratory (LHMEL). The bulk density of the CMC tubes was approximately 2.2 grams per cubic centimeters. The performance of cryogenically cooled CMCs was compared with uncooled CMCs against similar thermal loads, and fundamental property data collected for this relatively new breed of CMC. Finally, test thrust cells were fabricated from the functionally graded composite and tested using liquid H2 and O2 propellants at NASA Glen.

Patterson , Mark↗

Development of a biowaste resistojet propulsion system propellant management and control subsystem.

The subject subsystem is under development as the major portion of an overall biowaste resistojet system development program. The design is based on the Space Station model, but incorporates features compatible with all envisioned/anticipated advancements in the interfacing environmental control life support (EC/LS) system. Results to date, for system design, development plan, component selection, and system acceptance test will be presented. Subsystem usage in functional system tests to be performed at Langley Research Center, and its application to an envisioned and integrated system, and extended manned tests, are delineated. Expanded applications of the subsystem, to control/limit external contamination of manned spacecraft, are identified.-

Greco, R. V.↗

Activation of the E1 Ultra High Pressure Propulsion Test Facility at Stennis Space Center

After a decade of construction and a year of activation the El Ultra High Pressure Propulsion Test Facility at NASA's Stennis Space Center is fully operational. The El UHP Propulsion Test Facility is a multi-cell, multi-purpose component and engine test facility . The facility is capable of delivering cryogenic propellants at low, high, and ultra high pressures with flow rates ranging from a few pounds per second up to two thousand pounds per second. Facility activation is defined as a series of tasks required to transition between completion of construction and facility operational readiness. Activating the El UHP Propulsion Test Facility involved independent system checkouts, propellant system leak checks, fluid and gas sampling, gaseous system blow downs, pressurization and vent system checkouts, valve stability testing, valve tuning cryogenic cold flows, and functional readiness tests.

Messer, Bradley↗

Postflight Quiet Stance Stability of Astronauts Following Recovery From a Simulated Fall

INTRODUCTION: Astronauts returning from space flight universally present with postural ataxia. Throughout the Space Shuttle Program, measurement of ataxia has concentrated on sway in the anterior-posterior plane. Implementation of an interdisciplinary pre- and postflight study (Functional Task Test, FTT) designed to evaluate both astronaut postflight functional performance and related physiological changes has allowed the investigation of postural instability by characterizing dynamic stabilographic sway patterns. METHODS: Six astronauts from short-duration (Shuttle) and three from long-duration (ISS) flights were required to recover from a simulated fall. Subjects with eyes open, wearing running shoes lay prone on the floor for 2 minutes and then quickly stood up, maintained a quiet stance for 3 minutes, arms relaxed along the side of the body, and feet comfortably placed on the force plate. Crewmembers were tested twice before flight, on landing day (Shuttle only), and 1, 6, and 30 days after flight. Anterior-posterior (AP) and medial-lateral (ML) center-of-pressure (COP) coordinates were calculated from the ground reaction forces collected at 500 Hz. The 3-minute quiet stance trial was broken into three 1-minute segments for stabilogram diffusion analysis. A mean sway speed (rate of change of COP displacement) was also calculated as an additional postural stability parameter. RESULTS/CONCLUSION: While there was considerable variation, most of crewmembers tested exhibited increased stochastic activity evidenced by larger short-term COP diffusion coefficients postflight in both the AP and ML planes, suggesting significant changes in postural control mechanisms, particularly control of lower limb muscle function. As expected, postural instability of ISS astronauts on the first day postflight was similar to that of Shuttle crewmembers on landing day. Recoveries of stochastic activity and mean sway speed to baseline levels were typically observed by the 30th day postflight for both long-duration and short-duration crewmembers. Dynamic postural stability characteristics obtained in this low-impact study complement the data measured with computerized dynamic posturography.

Reschke, M. F.↗

Promoted Ignition and Burning Tests of Stainless Steel in Flowing and Nonflowing Oxygen

The Industry-Sponsored Metals Combustion Test Program 96-1 was coordinated through Wendell Hull & Associates, Inc. on behalf of several contributing companies, and all design and testing was performed at the NASA White Sands Test Facility. Phase I of this test program studied the threshold pressure for self-sustained burning of various types and sizes of stain less steel rods in nonflowing oxygen, as observed in Standard Test Method for Determining the Combustion Behavior of Metallic Materials in Oxygen-Enriched Atmospheres (ASTM G 124-95). Phase II studied the ignition and propagation of burning of 316L stainless steel rods and pipe in flowing gaseous oxygen. The test sample configurations were chosen to replicate previous promoted ignition and burning tests as well as to represent geometries and cross-sectional thicknesses common in industrial piping applications. The gas pressw'es and velocities for the test matrix were selected to generally compare with CGA G-4.4 guidelines for the use of stain less steel in oxygen service. This paper summarizes the results from the Phase I nonflowing oxygen tests and presents in detail the results of the Phase II flowing oxygen tests. The maximum sample burn-length is shown as a function of test pressure in Phase 1 and also as a function of gas velocity in Phase IT. These results indicate that flowing oxygen, under the given test conditions, significantly affects maximum sample burn length as compared to nonflowing oxygen. Supplementary flowing oxygen test data on stainless steel rods from a follow-up test program are consistent with these results and are presented herein.

Forsyth, Elliot T.↗

Solar cell contact pull strength as a function of pull-test temperature

Four types of solar cell contacts were given pull-strength tests at temperatures between -173 and +165 C. Contacts tested were: (1) solder-coated titanium-silver contacts on n-p cells, (2) palladium-containing titanium-silver contacts on n-p cells, (3) titanium-silver contacts on 0.2-mm-thick n-p cells, and (4) solder-coated electroless-nickel-plated contacts on p-n cells. Maximum pull strength was demonstrated at temperatures significantly below the air mass zero cell equilibrium temperature of +60 C. At the lowest temperatures, the chief failure mechanism was silicon fracture along crystallographic planes; at the highest temperatures, it was loss of solder strength. In the intermediate temperatures, many failure mechanisms operated. Pull-strength tests give a good indication of the suitability of solar cell contact systems for space use. Procedures used to maximize the validity of the results are described.

Yasui, R. K.↗

Orthostatic function during a stand test before and after head-up or head-down bedrest

The effects of head-down or head-up bedrest at -5, +10, +20, or +42 deg (simulating 0, 1/6, 1/3, and 2/3 g, respectively) for 6 hrs on four different days on the orthostatic tolerance were investigated by measuring relevant physiological reactions to orthostatic test taken before and after bedrest sessions. The multivariate analysis of variance statistical analyses indicates that there was no angle effect on any of the cardiovascular parameters monitored during the last 3 min of the stand test, suggesting that partial gravity loads would have no effect on the cardiovascular deconditioning exhibited postflight. There was, however, a significant elevation in the heart rate post-bedrest, and the heart rate increased on standing. Results from the stand test pre- and post-bedrest at -5 deg (but not at +10, +20, and +42 deg) were similar to those observed after space flight.

Lathers, Claire M.↗

Performance Testing of a Trace Contaminant Control Subassembly for the International Space Station

As part of the International Space Station (ISS) Trace Contaminant Control Subassembly (TCCS) development, a performance test has been conducted to provide reference data for flight verification analyses. This test, which used the U.S. Habitation Module (U.S. Hab) TCCS as the test article, was designed to add to the existing database on TCCS performance. Included in this database are results obtained during ISS development testing; testing of functionally similar TCCS prototype units; and bench scale testing of activated charcoal, oxidation catalyst, and granular lithium hydroxide (LiOH). The present database has served as the basis for the development and validation of a computerized TCCS process simulation model. This model serves as the primary means for verifying the ISS TCCS performance. In order to mitigate risk associated with this verification approach, the U.S. Hab TCCS performance test provides an additional set of data which serve to anchor both the process model and previously-obtained development test data to flight hardware performance. The following discussion provides relevant background followed by a summary of the test hardware, objectives, requirements, and facilities. Facility and test article performance during the test is summarized, test results are presented, and the TCCS's performance relative to past test experience is discussed. Performance predictions made with the TCCS process model are compared with the U.S. Hab TCCS test results to demonstrate its validation.

Perry, J. L.↗