Search NASA⌕ Search

SEARCH · Search NASA

Results for “general linear methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Homogeneous systems with quadratic integrals, Lie-Poisson quasibrackets, and Kovalevskaya's method

We consider differential equations with quadratic right-hand sides that admit two quadratic first integrals, one of which is a positive-definite quadratic form. We indicate conditions of general nature under which a linear change of variables reduces this system to a certain 'canonical' form. Under these conditions, the system turns out to be divergenceless and can be reduced to a Hamiltonian form, but the corresponding linear Lie-Poisson bracket does not always satisfy the Jacobi identity. In the three-dimensional case, the equations can be reduced to the classical equations of the Euler top, and in four-dimensional space, the system turns out to be superintegrable and coincides with the Euler-Poincaré equations on some Lie algebra. In the five-dimensional case we find a reducing multiplier after multiplying by which the Poisson bracket satisfies the Jacobi identity. In the general case for n>5 we prove the absence of a reducing multiplier. As an example we consider a system of Lotka-Volterra type with quadratic right-hand sides that was studied by Kovalevskaya from the viewpoint of conditions of uniqueness of its solutions as functions of complex time. Bibliography: 38 titles.

97 MATHEMATICS AND COMPUTING↗

Slow gantry rotation acquisition technique for on-board four-dimensional digital tomosynthesis

Purpose: Four-dimensional cone-beam computed tomography (4D CBCT) has been investigated for motion imaging in the radiotherapy treatment room. The drawbacks of 4D CBCT are long scan times and high imaging doses. The aims of this study were to develop and investigate a slow gantry rotation acquisition protocol for four-dimensional digital tomosynthesis (4D DTS) as a faster, lower dose alternative to 4D CBCT. Methods: This technique was implemented using an On-Board Imager kV imaging system (Varian Medical Systems, Palo Alto, CA) mounted on the gantry of a linear accelerator. The general procedure for 4D DTS imaging using slow gantry rotation acquisition consists of the following steps: (1) acquire projections over a limited gantry rotation angle in a single motion with constant frame rate and gantry rotation speed; (2) generate a respiratory signal and temporally match projection images with appropriate points from the respiratory signal; (3) use the respiratory signal to assign phases to each of the projection images; (4) sort projection images into phase bins; and (5) reconstruct phase images. Phantom studies were conducted to validate theoretically derived relationships between acquisition and respiratory parameters. Optimization of acquisition parameters was then conducted by simulating lung scans using patient data. Lung tumors with approximate volumes ranging from 0.12 to 1.53 cm{sup 3} were studied. Results: A protocol for slow gantry rotation 4D DTS was presented. Equations were derived to express relationships between acquisition parameters (frame rate, phase window, and angular intervals between projections), respiratory cycle durations, and resulting acquisition times and numbers of projections. The phantom studies validated the relationships, and the patient studies resulted in determinations of appropriate acquisition parameters. The phase window must be set according to clinical goals. For 10% phase windows, we found that appropriate frame rates ranging from 2 to 5 frames/s, gantry rotation speeds ranging from 0.44 to 1.03 deg./s, and aiming for an approximate maximum angular interval of 3.4 deg. between projections in phase bins were appropriate for dose, scan time, and tumor visibility optimization. Adequate tumor visibility was achieved for coronal 4D DTS images of all three lung tumors with acquisition times ranging from 0.45 to 2.12 min. vs 1.84 to 4.24 min for 4D CBCT. 4D DTS imaging doses ranged from 0.12 to 0.72 times the dose of a standard CBCT scan vs 0.48 to 1.44 times the dose of a standard CBCT scan for 4D CBCT. Conclusions: A slow gantry rotation acquisition technique for 4D DTS was developed and investigated. Study results indicated that 4D DTS is a feasible technique for imaging lung tumor motion in the treatment room and requires shorter acquisition times and less imaging dose than 4D CBCT for larger tumors that do not require large scan angles for sagittal views and for situations where only coronal views are needed to meet clinical needs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Energy stable discontinuous Galerkin methods for Maxwell's equations in nonlinear optical media

The propagation of electromagnetic waves in general media is modeled by the time-dependent Maxwell's partial differential equations (PDEs), coupled with constitutive laws that describe the response of the media. In this work, we focus on nonlinear optical media whose response is modeled by a system of first order nonlinear ordinary differential equations (ODEs), which include a single resonance linear Lorentz dispersion, and the nonlinearity comes from the instantaneous electronic Kerr response and the residual Raman molecular vibrational response. To design efficient, accurate, and stable computational methods, we apply high order discontinuous Galerkin discretizations in space to the hybrid PDE-ODE Maxwell system with several choices of numerical fluxes, and the resulting semi-discrete methods are shown to be energy stable. Under some restrictions on the strength of the nonlinearity, error estimates are also established. When we turn to fully discrete methods, the challenge to achieve provable stability lies in the temporal discretizations of the nonlinear terms. To overcome this, novel strategies are proposed to treat the nonlinearity in our model within the framework of the second-order leap-frog and implicit trapezoidal time integrators. The performance of the overall algorithms are demonstrated through numerical simulations of kink and antikink waves, and third-harmonic generation in soliton propagation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dedicated beam position monitor pair for model-independent lattice characterization at NSLS-II

This paper reports recent lattice characterization results obtained at the National Synchrotron Light Source II (NSLS-II) storage ring, conducted without reliance on a lattice model. A pair of beam position monitors (BPMs) with bunch-by-bunch (B$\times$B) resolution, were recently installed in a section of the storage ring free of magnetic fields. The new BPM pair measured the beam, or bunch’s transverse Poincaré map precisely after the beam was excited. Linear one-turn-matrices (OTM) were then derived, and from these, the 4-dimensional coupled Twiss parameters were extracted at the locations of the BPM pair. By normalizing beam oscillation amplitudes with the Twiss parameters, the global action-variables were obtained. Additionally, these action-variables facilitated the measurement of the local Twiss parameters observed by other BPMs independent on lattice model. This method is general, and particularly useful in certain scenarios such as a round beam mode in a diffraction-limited light source ring. We applied it to assess both weakly and strongly coupled lattices at the NSLS-II ring. Through analysis of the strongly coupled lattice, the quadrupole tilt errors were estimated to be less than 400 μrad. Utilizing the BPMs’ B$\times$B resolution, for the first time we observed the variations of the linear lattice along a long bunch-train.

36 MATERIALS SCIENCE↗

Higher-order finite-difference formulation of periodic Orbital-free Density Functional Theory

We present a real-space formulation and higher-order finite-difference implementation of periodic Orbital-free Density Functional Theory (OF-DFT). Specifically, utilizing a local reformulation of the electrostatic and kernel terms, we develop a generalized framework for performing OF-DFT simulations with different variants of the electronic kinetic energy. In particular, we propose a self-consistent field (SCF) type fixed-point method for calculations involving linear-response kinetic energy functionals. In this framework, evaluation of both the electronic ground-state and forces on the nuclei are amenable to computations that scale linearly with the number of atoms. We develop a parallel implementation of this formulation using the finite-difference discretization. We demonstrate that higher-order finite-differences can achieve relatively large convergence rates with respect to mesh-size in both the energies and forces. Additionally, we establish that the fixed-point iteration converges rapidly, and that it can be further accelerated using extrapolation techniques like Anderson's mixing. We validate the accuracy of the results by comparing the energies and forces with plane-wave methods for selected examples, including the vacancy formation energy in Aluminum. Overall, the suitability of the proposed formulation for scalable high performance computing makes it an attractive choice for large-scale OF-DFT calculations consisting of thousands of atoms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A hybrid approach for rapid, accurate, and direct kilovoltage radiation dose calculations in CT voxel space

Purpose: To develop and validate a fast and accurate method that uses computed tomography (CT) voxel data to estimate absorbed radiation dose at a point of interest (POI) or series of POIs from a kilovoltage (kV) imaging procedure. Methods: The authors developed an approach that computes absorbed radiation dose at a POI by numerically evaluating the linear Boltzmann transport equation (LBTE) using a combination of deterministic and Monte Carlo (MC) techniques. This hybrid approach accounts for material heterogeneity with a level of accuracy comparable to the general MC algorithms. Also, the dose at a POI is computed within seconds using the Intel Core i7 CPU 920 2.67 GHz quad core architecture, and the calculations are performed using CT voxel data, making it flexible and feasible for clinical applications. To validate the method, the authors constructed and acquired a CT scan of a heterogeneous block phantom consisting of a succession of slab densities: Tissue (1.29 cm), bone (2.42 cm), lung (4.84 cm), bone (1.37 cm), and tissue (4.84 cm). Using the hybrid transport method, the authors computed the absorbed doses at a set of points along the central axis and x direction of the phantom for an isotropic 125 kVp photon spectral point source located along the central axis 92.7 cm above the phantom surface. The accuracy of the results was compared to those computed with MCNP, which was cross-validated with EGSnrc, and served as the benchmark for validation. Results: The error in the depth dose ranged from -1.45% to +1.39% with a mean and standard deviation of -0.12% and 0.66%, respectively. The error in the x profile ranged from -1.3% to +0.9%, with standard deviations of -0.3% and 0.5%, respectively. The number of photons required to achieve these results was 1x10{sup 6}. Conclusions: The voxel-based hybrid method evaluates the LBTE rapidly and accurately to estimate the absorbed x-ray dose at any POI or series of POIs from a kV imaging procedure.

60 APPLIED LIFE SCIENCES↗

Beam loading compensation of traveling wave linacs through the time dependence of the rf drive

Beam loading in traveling-wave linear accelerating structures leads to unacceptable spread of particle energies across an extended train of bunched particles due to beam-induced field and dispersion. Methods for modulating the rf power driving linacs are effective at reducing energy spread, but for general linacs do not have a clear analytic foundation. We report here methods for calculating how to modulate the rf drive in arbitrarily nonuniform traveling-wave linacs within the convective-transport (power-diffusion) model that results in no additional energy spread due to beam loading (but not dispersion). Varying group velocity, loss factor, and cell quality factor within a structure, and nonzero particle velocity, are handled.

43 PARTICLE ACCELERATORS↗

Interactions in Theories with Mixed Symmetry Tensor Fields: Yes-Go Results

Some recent yes-go results concerning consistent couplings involving mixed symmetry tensor fields are reported. Only particular classes of mixed symmetry tensor fields, which are dual to linearized gravity in various dimensions, are considered. The method used to generate consistent couplings is based on the deformation of the solution to the master equation combined with specific techniques of local Becchi-Rouet-Stora-Tyutin cohomology. In each case the deformations are constructed under the general hypotheses of analyticity in the coupling constant, space-time locality, Lorentz covariance, Poincare invariance, preservation of the differential order of the interacting field equations with respect to their free limit. The emerging results indicate that dual formulations of linearized gravity are far from being rigid under the introduction of consistent couplings, so there is still hope for providing an alternative, finite setting for General Relativity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low-Rank Solution Methods for Stochastic Eigenvalue Problems

In this report, we study efficient solution methods for stochastic eigenvalue problems arising from discretization of self-adjoint partial differential equations with random data, where the underlying operators depend linearly on the random parameters. With the stochastic Galerkin approach, the solutions are represented as generalized polynomial chaos expansions. When these solutions can be approximated well by low-rank objects, we introduce a low-rank variant of the inverse subspace iteration algorithm for computing one or several minimal eigenvalues and corresponding eigenvectors of parameter-dependent matrices. In the algorithm, the iterates are approximated by low-rank matrices, which leads to significant cost savings. Furthermore, the algorithm is tested on two benchmark problems, a stochastic diffusion problem with some poorly separated eigenvalues, and an operator derived from a discrete stochastic Stokes problem whose minimal eigenvalue is related to the inf-sup stability constant. Numerical experiments show that the low-rank algorithm produces accurate solutions compared to the Monte Carlo method, and it uses much less computational time than the original algorithm without low-rank approximation.

97 MATHEMATICS AND COMPUTING↗

Numerical solution of large scale Hartree–Fock–Bogoliubov equations

The Hartree–Fock–Bogoliubov (HFB) theory is the starting point for treating superconducting systems. However, the computational cost for solving large scale HFB equations can be much larger than that of the Hartree–Fock equations, particularly when the Hamiltonian matrix is sparse, and the number of electrons N is relatively small compared to the matrix size N b . We first provide a concise and relatively self-contained review of the HFB theory for general finite sized quantum systems, with special focus on the treatment of spin symmetries from a linear algebra perspective. We then demonstrate that the pole expansion and selected inversion (PEXSI) method can be particularly well suited for solving large scale HFB equations. For a Hubbard-type Hamiltonian, the cost of PEXSI is at most $\mathcal{O}$(N b 2 ) for both gapped and gapless systems, which can be significantly faster than the standard cubic scaling diagonalization methods. We show that PEXSI can solve a two-dimensional Hubbard-Hofstadter model with N b up to 2.88 × 10 6 , and the wall clock time is less than 100 s using 17 280 CPU cores. Finally, this enables the simulation of physical systems under experimentally realizable magnetic fields, which cannot be otherwise simulated with smaller systems.

97 MATHEMATICS AND COMPUTING↗

Calculation of the gas temperature in a throughflow atmospheric pressure dielectric barrier discharge torch by spectral line shape analysis

An analysis of spectral line profiles is used to calculate the gas temperature and to estimate the upper limit of the electron density in an atmospheric pressure dielectric barrier discharge torch. Two transitions are studied, that of helium (He) at 587.5 nm and that of hydrogen (H{sub {beta}}) at 486.1 nm, both observed in the spectra of the light emitted from the gap-space region. Relevant broadening mechanisms including the Doppler and Stark effects, as well as the collision processes between an emitter and a neutral particle, are reviewed. It is deduced that the main contribution to the broadened profiles is due to collisions. Through knowledge of the van der Waals interaction potential, a general expression for determining the gas temperature is derived and applied to each transition. The results obtained from both lines are in agreement; i.e., the gas temperature is found to be 460{+-}60 K at the highest voltage applied. This value is consistent with the experimental observation that at these conditions the afterglow plasma cannot ignite paper, whose ignition temperature is 507 K. Since no signature of the Stark effect can be detected either in He or H{sub {beta}} transition, the upper limit of the electron density, estimated from the uncertainty on the H{sub {beta}} linewidth, is 4x10{sup 12} cm{sup -3}. The generality of the method allows one to determine the temperature as a function of other parameters, such as voltage and flow rate. Concerning the applied voltage, the gas temperature increases linearly from 315{+-}30 to 460{+-}60 K, as derived from both lines. Over the same voltage range, a similar behavior is found for the rotational temperature, as deduced from the first negative B({sup 2}{sigma}{sub u}{sup +},v=0){yields}X({sup 2}{sigma}{sub g}{sup +},v=0) transition of the molecular nitrogen ion. However, the temperature varies between 325{+-}30 and 533{+-}15 K, indicating an overestimation of the gas temperature. On the other hand, the gas temperature derived from each of the lines does not show a significant variation with the He flow rate in the range of 5-40 l/min.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cohomology Methods in Causal Perturbation Theory

Various problems in perturbation theory of (quantum) gauge models can be rephrased in the language of cohomology theory. This was already noticed in the functional formulation of perturbative gauge theories. Causal perturbation theory is a fully quantum approach: is works only with the chronological products which are defined as operator-valued distributions in the Fock space of the model. The use of causal perturbation theory leads to similar cohomology problems; the main difference with respect to the functional methods comes from the fact that the gauge transformation of the causal approach is, essentially, the linear part of the non-linear BRST transformation.Using these methods it is possible to give a nice determination of the interaction Lagrangians for gauge models (Yang-Mills and gravitation in the linear approximation); one obtains with this method the unicity of the interaction Lagrangian up to trivial terms. The case of quantum gravity is highly non-trivial and can be generalized with this method to the massive graviton case. Going to higher orders of perturbation theory one finds quantum anomalies. Again the cohomological methods can be used to determine the generic form of these anomalies. Finally, one can investigate the arbitrariness of the chronological products in higher orders and reduce this problem to cohomology methods also.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First principles study on electronic structure and elastic properties of LaCd and LaHg

Full -potential linearized augmented plane wave method (FP- LAPW) has been used for the comparative study of electronic structure and elastic properties of CsCl-type LaCd and LaHg intermetallic compounds using generalized gradient approximation (GGA). The density of states at the Fermi Level, N (E{sub F}), is found to be 0.06 and 3.03 states/eV for LaCd and LaHg respectively. We report elastic constants for these compounds for the first time. The ductility/brittleness of these compounds has been analyzed using Pugh rule and Cauchy’s pressure.

36 MATERIALS SCIENCE↗

Algebraic solutions of shape-invariant position-dependent effective mass systems

Keeping in view the ordering ambiguity that arises due to the presence of position-dependent effective mass in the kinetic energy term of the Hamiltonian, a general scheme for obtaining algebraic solutions of quantum mechanical systems with position-dependent effective mass is discussed. We quantize the Hamiltonian of the pertaining system by using symmetric ordering of the operators concerning momentum and the spatially varying mass, initially proposed by von Roos and Lévy-Leblond. The algebraic method, used to obtain the solutions, is based on the concepts of supersymmetric quantum mechanics and shape invariance. In order to exemplify the general formalism a class of non-linear oscillators has been considered. This class includes the particular example of a one-dimensional oscillator with different position-dependent effective mass profiles. Explicit expressions for the eigenenergies and eigenfunctions in terms of generalized Hermite polynomials are presented. Moreover, properties of these modified Hermite polynomials, like existence of generating function and recurrence relations among the polynomials have also been studied. Furthermore, it has been shown that in the harmonic limit, all the results for the linear harmonic oscillator are recovered.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Double soft limits of cosmological correlations

Correlation functions of two long-wavelength modes with several short-wavelength modes are shown to be related to lower order correlation functions, using the background wave method, and independently, by exploiting symmetries of the wavefunction of the Universe. These soft identities follow from the non-linear extension of the adiabatic modes of Weinberg, and their generalization by Hinterbichler et al. The extension is shown to be unique. A few checks of the identities are presented.

79 ASTRONOMY AND ASTROPHYSICS↗

A perturbative approach to the redshift space power spectrum: beyond the Standard Model

We develop a code to produce the power spectrum in redshift space based on standard perturbation theory (SPT) at 1-loop order. The code can be applied to a wide range of modified gravity and dark energy models using a recently proposed numerical method by A.Taruya to find the SPT kernels. This includes Horndeski's theory with a general potential, which accommodates both chameleon and Vainshtein screening mechanisms and provides a non-linear extension of the effective theory of dark energy up to the third order. Focus is on a recent non-linear model of the redshift space power spectrum which has been shown to model the anisotropy very well at relevant scales for the SPT framework, as well as capturing relevant non-linear effects typical of modified gravity theories. We provide consistency checks of the code against established results and elucidate its application within the light of upcoming high precision RSD data.

79 ASTRONOMY AND ASTROPHYSICS↗

Higher-order phase shift reconstruction approach

Purpose: Biological soft tissues encountered in clinical and preclinical imaging mainly consists of atoms of light elements with low atomic numbers and their elemental composition is nearly uniform with little density variation. Hence, x-ray attenuation contrast is relatively poor and cannot achieve satisfactory sensitivity and specificity. In contrast, x-ray phase-contrast provides a new mechanism for soft tissue imaging. The x-ray phase shift of soft tissues is about a thousand times greater than the x-ray absorption over the diagnostic x-ray energy range, yielding a higher signal-to-noise ratio than the attenuation contrast counterpart. Thus, phase-contrast imaging is a promising technique to reveal detailed structural variation in soft tissues, offering a high contrast resolution between healthy and malignant tissues. Here the authors develop a novel phase retrieval method to reconstruct the phase image on the object plane from the intensity measurements. The reconstructed phase image is a projection of the phase shift induced by an object and serves as input to reconstruct the 3D refractive index distribution inside the object using a tomographic reconstruction algorithm. Such x-ray refractive index images can reveal structural features in soft tissues, with excellent resolution differentiating healthy and malignant tissues. Methods: A novel phase retrieval approach is proposed to reconstruct an x-ray phase image of an object based on the paraxial Fresnel-Kirchhoff diffraction theory. A primary advantage of the authors' approach is higher-order accuracy over that with the conventional linear approximation models, relaxing the current restriction of slow phase variation. The nonlinear terms in the autocorrelation equation of the Fresnel diffraction pattern are eliminated using intensity images measured at different distances in the Fresnel diffraction region, simplifying the phase reconstruction to a linear inverse problem. Numerical experiments are performed to demonstrate the accuracy and stability of the proposed approach. Results: The proposed reconstruction formula is a generalization of the transport of intensity equation (TIE). It has the second-order accuracy compared to the linear model used in the conventional phase retrieval approach. The numerical experiments demonstrate that the accuracy and stability of the proposed phase reconstruction method outperforms the TIE-based reconstruction method. Conclusions: A novel approach has been proposed to retrieve an x-ray phase shift image induced by an object from intensity images measured at different distances in the Fresnel diffraction region. The authors' approach has the second-order accuracy and is able to retrieve the phase shift of an object stably, overcoming the restriction of slow phase variation assumed by the conventional phase retrieval techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗