Search NASA⌕ Search

SEARCH · Search NASA

Results for “interval analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Tonopah Test Range Air Monitoring: CY2018 Meteorological, Radiological, and Wind Transported Particulate Observations

In 1963, the U.S. Department of Energy (DOE) (formerly the Atomic Energy Commission [AEC]), implemented Operation Roller Coaster on the Tonopah Test Range (TTR) and an adjacent area of the Nevada Test and Training Range (NTTR) (formerly the Nellis Air Force Range). This operation resulted in radionuclide-contaminated soils at the Double Tracks site and Clean Slate I, II, and III sites. This report documents observations made during ongoing monitoring of radiological, meteorological, and dust conditions at stations installed adjacent to the Clean Slate sites and at the TTR Sandia National Laboratories (SNL) Range Operations Center (ROC). The primary objective of the monitoring effort is to support the DOE Environmental Management Nevada Program (EM NV) in the safe remediation of the environmental legacy of nuclear device development and testing by determining if wind blowing across the Clean Slate sites is transporting particles of radionuclide-contaminated soil beyond the physical and administrative boundaries of the sites, and to provide information for designing long-term monitoring of the sites. The monitoring program in 2018 included five stations. Station 400, located within TTR Area 3 and near the ROC, monitors conditions near the local workforce center. Stations 401 and 403 are located on the northern and southeastern perimeter fence lines, respectively, of the Clean Slate III site. Stations 404 and 405 are along the northern and eastern boundary fence, respectively, at Clean Slate II. The stations are generally downwind of the contaminated areas during either northwesterly or southerly winds, which are the predominant wind directions. The stations—which are similar in design to the Community Environmental Monitoring Program (CEMP) stations operating at locations surrounding the Nevada National Security Site and TTR—include meteorological instruments and continuous-flow, low-volume air samplers. Three pressurized ionization chambers for measuring gamma energy are in use at Stations 400, 401, and 403. Saltation sensors and saltation traps are deployed at the stations adjacent to the Clean Slate sites. Detailed meteorological data are recorded on data loggers, with periodic uploads via a satellite system to the Western Regional Climate Center (WRCC) at Desert Research Institute (DRI), to monitor instrument and site conditions. Air filter samples are collected every two weeks and the deposits in the saltation traps are collected when a sufficient sample mass for analysis has accumulated (generally a six- to eight-month interval). Monitoring at TTR in calendar year (CY) 2018 provided surveillance of both ambient conditions, and ground disturbance associated with remediation activities at Clean Slate II and III. The first half of CY2018 data from Stations 404 and 405 at Clean Slate II were collected during remediation activities at that site, and data collected during the final third of the year at Stations 401 and 403 at Clean Slate III coincided with remediation work at the site. Ambient conditions prevailed at Station 400 throughout the year. Dust transport by suspension and saltation is strongly dependent on wind speed. Concentrations of PM 10 (particulate matter of aerodynamic diameter ≤10 micrometers [μm], a size fraction of small particles that are suspended in the air and can be easily inhaled) remain low until winds exceed approximately 32 kilometers per hour (km/hr) (20 miles per hour [mph]). Saltation particle counts also increase above the same general threshold wind speed. Wind speeds in excess of 32 km/hr (20 mph) occur less than three percent of the time at the sites. Ground disturbing remediation activities were carried out at Clean Slate II from October 31, 2017, until July 26, 2018. Station 404 is located closest to the remediation area and is downwind of the area when winds are from the south. By late November, analysis of dust from the air sampler at Station 404 registered increases in plutonium-239+240 ( 239+240 Pu) concentrations. Peak plutonium concentrations, accompanied by elevated gross alpha concentrations and the detection of americium-241 ( 241 Am) by gamma spectroscopy, occurred between March and May 2018. During spring and early summer of 2018, elevated radionuclide concentrations were also measured in dust collected from the air sampler at Station 405, which is more than twice the distance from the remediation activity as Station 404. A minor but sustained increase in gross alpha concentration of suspended dust collected at Stations 400, 401, and 403 was also observed starting in May 2018 and continuing into August. Stations 401 and 403 are approximately 4.8 to 6.4 km (three to four miles) from Clean Slate II and Station 400 is approximately 13 km (eight miles) from that site. The radionuclide content of material that saltated into the passive Big Spring Number Eight (BSNE) traps during the Clean Slate II remediation period increased in both the traps facing toward and away from the fenced contamination area at Station 404, with the largest increases in concentration (almost five times the previous 239+240 Pu concentration) observed in the traps facing the fenced area. The radionuclide concentration in material in the trap facing away from the fence more than doubled from that measured in 2017. A similar increase was observed for the saltation trap facing away from the fenced area at Station 405, although no increase was observed for material captured in the trap facing the fenced area. Particles ranging in size from 50 to 500 µm generally move by saltation processes and are not expected to significantly contribute to dose for someone breathing in the standard respiratory zone for adult humans (1.5 to 1.7 m [4.9 to 5.6 ft] above ground level) because they are too large to be entrained in the air as suspended dust. Remediation activities at Clean Slate III began on September 5, 2018, and continued until a brief hiatus started on December 20, 2018. Although Station 401 is much closer to the remediation area than Station 403, the first increase in gross alpha and 239+240 Pu concentrations was noted in dust from filters collected at Station 403 in early November 2018. The highest radionuclide concentrations of 2018 at the Clean Slate III stations were recorded in air samples taken from Stations 401 and 403 in late December 2018 and these concentrations were comparable between the two station locations. Gamma rate data measured by the PICs was slightly higher than the annual average at Stations 401 and 403 after remediation activities began, but no single measurement was outside of the range observed in 2018 prior to remediation activities. No increase in radionuclide concentration was observed for the Clean Slate III remediation time period on air filters collected from the other stations. Radiological monitoring at Station 400—which is located at the ROC, and therefore the closest regularly staffed work location to the Clean Slate sites—recorded a higher mean gross alpha activity from dust collected on air sampler filters than in previous years. The individual biweekly air filters yielded measurements of gross alpha that were at or below the mean plus one standard deviation measured in CY2017, except for the period from April 25, 2018, through September 12, 2018. Nonetheless, gamma spectroscopy of all air filters from Station 400 identified only naturally occurring radionuclides, with no detection of americium-241 ( 241 Am) (which is used as an indicator of plutonium-241[ 241 Pu]). Alpha spectroscopy of selected air filters collected at Station 400 did not detect plutonium-238 ( 238 Pu) or 239+240 Pu above the analytical detection limit. Gross beta and gamma exposure rate data were comparable to data from regional CEMP stations. No saltation traps are deployed at Station 400. Considering the ambient monitoring periods during CY2018, the monitoring stations adjacent to the Clean Slate sites recorded above-background 238 Pu and 239+240 Pu concentrations (SNL, 1998; Turner et al., 2003) in samples collected by passive saltation traps and on selected air filters. These observations were consistent with previous years and indicated that radionuclide movement occurred under ambient conditions by processes of both saltation and suspension. The presence of radionuclides in all saltation traps, both upwind and downwind of the fenced contamination areas, was consistent with previous radiological survey results (EG&G, 1979) that show lower concentration radiologically contaminated material dispersed outside the fenced area. Although 239+240 Pu concentrations in the air filter samples were sometimes orders of magnitude higher than background, the concentrations were below risk-based action levels defined for an industrial area worker scenario (U.S. DOE, 2014). The interception of airborne dust with above-background radionuclide concentrations demonstrates that dispersal processes are continuing. Strong winds are the driver for both suspension and saltation of dust and soil. The recorded wind speed and PM10 during remediation activities at Clean Slate II and III identified discrete wind events lasting approximately five to eight hours each, which accounted for the greatest PM 10 concentrations at the monitoring stations. These events captured the effect of winds from the northwest and from the south. The observed differences in dust loading and radionuclide concentrations for the monitoring stations when they were either upwind or downwind of the contamination area identify the remediation area as a source of plutonium contaminated dust. The increase in concentration of radionuclides in airborne dust during the remediation activities, compared with measurements under previous ambient conditions (mean 239+240 Pu concentrations during remediation activities are approximately nine to 40 times higher compared to pre-remediation concentrations, depending on monitoring station), highlights the impact of land disturbance on wind-borne contaminant transport from the Clean Slate test areas. The meteorological and particulate matter monitoring indicated that conditions for wind-borne contaminant movement exist at the Clean Slate sites, and that transport of radionuclide-contaminated soil by both suspension and saltation occurred under ambient conditions and accelerated when the sites were disturbed. The 239+240 Pu alpha spectroscopy results indicated that airborne concentrations during remediation activities ranged from 2 × 10-16 to 380 × 10-16 µCi/ml. These results can be compared to the derived air concentration limit for 239 Pu of 6 × 10-11 µCi/ml for occupational workers contained in Code of Federal Regulations 10 CFR 835, Occupational Radiation Protection. Even though the air sampling results document an increase in concentration during remediation activities, the observed concentrations are less than 0.06 percent of the occupational limit. The Corrective Action Unit (CAU) closure strategy uses a risk-based approach, whereby acceptable contaminant concentrations are determined as a function of anticipated human exposure.

54 ENVIRONMENTAL SCIENCES↗

Risk of Positive Sentinel Lymph Node After Neoadjuvant Systemic Therapy in Clinically Node-Negative Breast Cancer: Implications for Postmastectomy Radiation Therapy and Immediate Breast Reconstruction

Background: Residual axillary lymph node involvement after neoadjuvant systemic therapy (NST) is the determining factor for postmastectomy radiation therapy (PMRT). Preoperative identification of patients needing PMRT is essential to enable shared decision-making when choosing the optimal timing of breast reconstruction. We determined the risk of positive sentinel lymph node (SLN) after NST in clinically node-negative (cN0) breast cancer. Methods: All cT1-3N0 patients treated with NST followed by mastectomy and SLNB between 2010 and 2016 were identified from the Netherlands Cancer Registry. Rate of positive SLN for different breast cancer subtypes was determined. Logistic regression analysis was performed to determine correlated clinicopathological variables with positive SLN. Results: In total 788 patients were included, of whom 25.0% (197/788) had positive SLN. cT1-3N0 ER+HER2+, cT1-3N0 ER−HER2+ , and cT1-2N0 triple-negative patients had the lowest rate of positive SLN: 7.2–11.5%, 0–6.3%, and 2.9–6.2%, respectively. cT1-3N0 ER+HER2− and cT3N0 triple-negative patients had the highest rate of positive SLN: 23.8–41.7% and 30.4%, respectively. Multivariable regression analysis showed that cT2 (odds ratio [OR] 1.93; 95% confidence interval [CI] 1.01–3.96), cT3 (OR 2.56; 95% CI 1.30–5.38), grade 3 (OR 0.44; 95% CI 0.21–0.91), and ER+HER2− subtype (OR 3.94; 95% CI 1.77–8.74) were correlated with positive SLN. Conclusions: In cT1-3N0 ER+HER2+, cT1-3N0 ER−HER2+, and cT1-2N0 triple-negative patients treated with NST, immediate reconstruction can be considered an acceptable option due to low risk of positive SLN. In cT1-3N0 ER+HER2− and cT3N0 triple-negative patients treated with NST, risks and benefits of immediate reconstruction should be discussed with patients due to the relatively high risk of positive SLN.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Brachytherapy Is Associated With Improved Survival in Inoperable Stage I Endometrial Adenocarcinoma: A Population-Based Analysis

Purpose: To assess the use of brachytherapy (BT) with or without external beam radiation (EBRT) in inoperable stage I endometrial adenocarcinoma in the United States and to determine the effect of BT on overall survival (OS) and cause-specific survival (CSS). Methods and Materials: Data between 1998 and 2011 from the National Cancer Institute's Surveillance, Epidemiology and End Results database were analyzed. Coarsened exact matching was used to adjust for differences in age and grade between patients who received BT and those who did not. Prognostic factors affecting OS and CSS were evaluated using the Kaplan-Meier product-limit method and a Cox proportional hazards regression model. Results: A total of 460 patients with inoperable stage I endometrial adenocarcinoma treated with radiation therapy were identified. Radiation consisted of either EBRT (n=260) or BT with or without EBRT (n=200). The only factor associated with BT use was younger patient age (median age, 72 vs 76 years, P=.001). Patients who received BT had a higher 3-year OS (60% vs 47%, P<.001) and CSS (82% vs 74%, P=.032) compared with those who did not. On multivariate analysis, BT use was independently associated with an improved OS (hazard ratio [HR] 0.67, 95% confidence interval [CI] 0.52-0.87) and CSS (HR 0.61, 95% CI 0.39-0.93). When patients were matched on age, BT use remained significant on multivariate analysis for OS (HR 0.65, 95% CI 0.48-0.87) and CSS (HR 0.52, 95% CI 0.31-0.84). When matched on age and grade, BT remained independently associated with improved OS and CSS (OS HR 0.62, 95% CI 0.46-0.83; CSS HR 0.57, 95% CI 0.34-0.92). Conclusion: Brachytherapy is independently associated with improved OS and CSS. It should be considered as part of the treatment regimen for stage I inoperable endometrial cancer patients undergoing radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Component-level Performance and Mass Sensitivity Analysis of NEP MW-class Power System

Nuclear electric propulsion (NEP) is a promising option towards enabling missions to Mars and is an area of interest for NASA’s Space Nuclear Propulsion project. This project is currently investigating technology development opportunities for an NEP vehicle. Physics-based modeling can be used in the early stages of technology development to gain understanding of the effects of technology and performance assumptions on the system performance and mass. This information can then inform technology maturation planning for near term development. By using a Brayton power conversion model and vehicle mass model for megawatt class NEP applications, a sensitivity analysis is performed to assess the impact of individual components’ performance on the power conversion system performance and system mass. A Monte Carlo simulation is also used to determine the variability in system mass based on uncertainty within the modeling parameters. The sensitivity analysis shows a high sensitivity to power conversion inlet temperature, compressor inlet temperature, and recuperator performance. A Monte Carlo analysis suggests a range of -10% to +15% for a 90% confidence interval on system mass based on the uncertainties in the model inputs.

Nuclear electric propulsion↗

Clinical and Dosimetric Predictors of Acute Severe Lymphopenia During Radiation Therapy and Concurrent Temozolomide for High-Grade Glioma

Purpose: Acute severe lymphopenia (ASL) frequently develops during radiation therapy (RT) and concurrent temozolomide (TMZ) for high-grade glioma (HGG) and is associated with decreased survival. The current study was designed to identify potential predictors of ASL, with a focus on actionable RT-specific dosimetric parameters. Methods and Materials: From January 2007 to December 2012, 183 patients with HGG were treated with RT+TMZ and had available data including total lymphocyte count (TLC) and radiation dose-volume histogram parameters. ASL was defined as TLC of <500/μL within the first 3 months from the start of RT. Stepwise logistic regression analysis was used to determine the most important predictors of ASL. Results: Fifty-three patients (29%) developed ASL. Patients with ASL had significantly worse overall survival than those without (median: 12.5 vs 20.2 months, respectively, P<.001). Stepwise logistic regression analysis identified female sex (odds ratio [OR]: 5.30; 95% confidence interval [CI]: 2.46-11.41), older age (OR: 1.05; 95% CI: 1.02-1.09), lower baseline TLC (OR: 0.92; 95% CI: 0.87-0.98), and higher brain volume receiving 25 Gy (V{sub 25Gy}) (OR: 1.03; 95% CI: 1.003-1.05) as the most significant predictors for ASL. Brain V{sub 25Gy} <56% appeared to be the optimal threshold (OR: 2.36; 95% CI: 1.11-5.01), with an ASL rate of 38% versus 20% above and below this threshold, respectively (P=.006). Conclusions: Female sex, older age, lower baseline TLC, and higher brain V{sub 25Gy} are significant predictors of ASL during RT+TMZ therapy for HGG. Maintaining the V{sub 25Gy} of brain below 56% may reduce the risk of ASL.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance of a machine learning-based decision model to help clinicians decide the extent of lymphadenectomy (D1 vs. D2) in gastric cancer before surgical resection

Background: Controversy still exists on the optimal surgical resection for potentially curable gastric cancer (GC). Use of radiologic evaluation and machine learning algorithms might predict extent of lymphadenectomy to limit unnecessary surgical treatment. We purposed to design a machine learning-based clinical decision-support model for predicting extent of lymphadenectomy (D1 vs. D2) in local advanced GC. Methods: Clinicoradiologic features available from routine clinical assignments in 557 patients with GCs were retrospectively interpreted by an expert panel blinded to all histopathologic information. All patients underwent surgery using standard D2 resection. Decision models were developed with a logistic regression (LR), support vector machine (SVM) and auto-encoder (AE) algorithm in 371 training and tested in 186 test data, respectively. The primary end point was to measure diagnostic performance of decision model and a Japanese gastric cancer treatment guideline version 4th (JPN 4th) criteria for discriminate D1 (pT1 + pN0) versus D2 (≥ pT1 + ≥ pN1) lymphadenectomy. Results: The decision model with AE analysis produced highest area under ROC curve (train: 0.965, 95% confidence interval (CI) 0.948–0.978; test: 0.946, 95% CI 0.925–0.978), followed by SVM (train: 0.925, 95% CI 0.902–0.944; test: 0.942, 95% CI 0.922–0.973) and LR (train: 0.886, 95% CI 0.858–0.910; test: 0.891, 95% CI 0.891–0.952). By this improvement, overtreatment was reduced from 21.7% (121/557) by treat-all pattern, to 15.1% (84/557) by JPN 4th criteria, and to 0.7–0.9% (4–5/557) by the new approach. Conclusions: The decision model with machine learning analysis demonstrates high accuracy for identifying patients who are candidates for D1 versus D2 resection. Its approximate 14–20% improvements in overtreatment compared to treat-all pattern and JPN 4th criteria potentially increase the number of patients with local advanced GCs who can safely avoid unnecessary lymphadenectomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Identifying Meteorologic and Oceanic Conditions Contributing to a Unique Phytoplankton Bloom Occurrence in Micronesia during October 2013

On the first several days of October 2013, daily chlorophyll a (chl a) data acquired by the Moderate Resolution Imaging Spectroradiometer (MODIS) onboard the National Aeronautics and Space Administration (NASA) Aqua satellite detected a marked increase in chlorophyll a concentrations (chl a) in the vicinity of Chuuk Lagoon and the Federated States of Micronesia. Such an increase, likely indicative of a phytoplankton bloom, has not been observed in this location at any other time during the MODIS-Aqua mission, which commenced in 2002 and continues to present. Examination of sea surface wind data from the Modern Era Retrospective analysis for Research and Applications Version 2 (MERRA-2) reanalysis dataset indicated that the region experienced a sequence of alternating elevated and very low wind speed events prior to the observation of the bloom. The influence of the winds can be seen in MERRA-2 sea surface skin temperature data. Elevated windspeeds for several days likely induced a mixing of deeper waters with higher nutrient levels to the surface, which was followed by stratification and phytoplankton growth during low wind intervals and finally transport induced by a brief high windspeed event. Analysis of hourly MERRA-2 maximum windspeed data over a 40-year period indicated that this sequence was climatologically rare.

Remote Sensing↗

Hypofractionated Versus Standard Radiation Therapy With or Without Temozolomide for Older Glioblastoma Patients

Purpose: Older patients with newly diagnosed glioblastoma have poor outcomes, and optimal treatment is controversial. Hypofractionated radiation therapy (HRT) is frequently used but has not been compared to patients receiving standard fractionated radiation therapy (SRT) and temozolomide (TMZ). Methods and Materials: We conducted a retrospective analysis of patients ≥65 years of age who received radiation for the treatment of newly diagnosed glioblastoma from 1994 to 2013. The distribution of clinical covariates across various radiation regimens was analyzed for possible selection bias. Survival was calculated using the Kaplan-Meier method. Comparison of hypofractionated radiation (typically, 40 Gy/15 fractions) versus standard fractionation (typically, 60 Gy/30 fractions) in the setting of temozolomide was conducted using Cox regression and propensity score analysis. Results: Patients received SRT + TMZ (n=57), SRT (n=35), HRT + TMZ (n=34), or HRT (n=9). Patients receiving HRT were significantly older (median: 79 vs 69 years of age; P<.001) and had worse baseline performance status (P<.001) than those receiving SRT. On multivariate analysis, older age (adjusted hazard ratio [AHR]: 1.06; 95% confidence interval [CI]: 1.01-1.10, P=.01), lower Karnofsky performance status (AHR: 1.02; 95% CI: 1.01-1.03; P=.01), multifocal disease (AHR: 2.11; 95% CI: 1.23-3.61, P=.007), and radiation alone (vs SRT + TMZ; SRT: AHR: 1.72; 95% CI: 1.06-2.79; P=.03; HRT: AHR: 3.92; 95% CI: 1.44-10.60, P=.007) were associated with decreased overall survival. After propensity score adjustment, patients receiving HRT with TMZ had similar overall survival compared with those receiving SRT with TMZ (AHR: 1.10, 95% CI: 0.50-2.4, P=.82). Conclusions: With no randomized data demonstrating equivalence between HRT and SRT in the setting of TMZ for glioblastoma, significant selection bias exists in the implementation of HRT. Controlling for this bias, we observed similar overall survival for HRT and SRT with concurrent TMZ among elderly patients, suggesting the need for a randomized trial to compare these regimens directly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single photon detection and timing in the Lunar Laser Ranging Experiment.

The goals of the Lunar Laser Ranging Experiment lead to the need for the measurement of a 2.5 sec time interval to an accuracy of a nanosecond or better. The systems analysis which included practical retroreflector arrays, available laser systems, and large telescopes led to the necessity of single photon detection. Operation under all background illumination conditions required auxiliary range gates and extremely narrow spectral and spatial filters in addition to the effective gate provided by the time resolution. Nanosecond timing precision at relatively high detection efficiency was obtained using the RCA C31000F photomultiplier and Ortec 270 constant fraction of pulse-height timing discriminator. The timing accuracy over the 2.5 sec interval was obtained using a digital interval with analog vernier ends. Both precision and accuracy are currently checked internally using a triggerable, nanosecond light pulser. Future measurements using sub-nanosecond laser pulses will be limited by the time resolution of single photon detectors.

Poultney, S. K.↗

The solar wind effect on cosmic rays and solar activity

The relation of cosmic ray intensity to solar wind velocity is investigated, using neutron monitor data from Kiel and Deep River. The analysis shows that the regression coefficient of the average intensity for a time interval to the corresponding average velocity is negative and that the absolute effect increases monotonously with the interval of averaging, tau, that is, from -0.5% per 100km/s for tau = 1 day to -1.1% per 100km/s for tau = 27 days. For tau 27 days the coefficient becomes almost constant independently of the value of tau. The analysis also shows that this tau-dependence of the regression coefficiently is varying with the solar activity.

Fujimoto, K.↗

Short-term variations of the galactic cosmic ray intensity - 1964-1967

A statistical analysis of time variations in ground-level nucleonic cosmic-ray intensity for the interval from 1964 to 1967 is presented which incorporates synoptic observations of the solar white-light corona as well as indices of photospheric and chromospheric activity. Correlation analysis of solar activity and short-term modulation reveals that all indices vary significantly on time scales near the solar rotation period and that the correlation function exhibits a quasi-sinusoidal variation that maximizes near zero lag. It is found that 27-day variations of the indices were most pronounced in 1966-1967, that recurrent cosmic-ray depressions occurred in conjunction with observed solar-wind disturbances, and that two categories of interplanetary disturbance are sufficient to account for the large recurrent cosmic-ray depressions in 1966-1967. It is suggested that flare-generated shocks were the main source of these recurrent cosmic-ray variations and that the contribution of corotating cosmic-ray disturbances to the observed recurrent modulation was probably very small. This hypothesis is tested against the correlation functions of solar and cosmic-ray indices.

Parker, G. D.↗

Fundamental relations between short-term RR interval and arterial pressure oscillations in humans

BACKGROUND: One of the principal explanations for respiratory sinus arrhythmia is that it reflects arterial baroreflex buffering of respiration-induced arterial pressure fluctuations. If this explanation is correct, then elimination of RR interval fluctuations should increase respiratory arterial pressure fluctuations. METHODS AND RESULTS: We measured RR interval and arterial pressure fluctuations during normal sinus rhythm and fixed-rate atrial pacing at 17.2+/-1.8 (SEM) beats per minute greater than the sinus rate in 16 healthy men and 4 healthy women, 20 to 34 years of age. Measurements were made during controlled-frequency breathing (15 breaths per minute or 0.25 Hz) with subjects in the supine and 40 degree head-up tilt positions. We characterized RR interval and arterial pressure variabilities in low-frequency (0.05 to 0.15 Hz) and respiratory-frequency (0.20 to 0.30 Hz) ranges with fast Fourier transform power spectra and used cross-spectral analysis to determine the phase relation between the two signals. As expected, cardiac pacing eliminated beat-to-beat RR interval variability. Against expectations, however, cardiac pacing in the supine position significantly reduced arterial pressure oscillations in the respiratory frequency (systolic, 6.8+/-1.8 to 2.9 +/-0.6 mm Hg2/Hz, P=.017). In contrast, cardiac pacing in the 40 degree tilt position increased arterial pressure variability (systolic, 8.0+/-1.8 to 10.8 +/-2.6, P=.027). Cross-spectral analysis showed that 40 degree tilt shifted the phase relation between systolic pressure and RR interval at the respiratory frequency from positive to negative (9 +/-7 degrees versus -17+/-11 degrees, P=.04); that is, in the supine position, RR interval changes appeared to lead arterial pressure changes, and in the upright position, RR interval changes appeared to follow arterial pressure changes. CONCLUSIONS: These results demonstrate that respiratory sinus arrhythmia can actually contribute to respiratory arterial pressure fluctuations. Therefore, respiratory sinus arrhythmia does not represent simple baroreflex buffering of arterial pressure.

NASA Discipline Cardiopulmonary↗

Ephemeris data and error analysis in support of a Comet Encke intercept mission

Utilizing an orbit determination based upon 65 observations over the 1961 - 1973 interval, ephemeris data were generated for the 1976-77, 1980-81 and 1983-84 apparitions of short period comet Encke. For the 1980-81 apparition, results from a statistical error analysis are outlined. All ephemeris and error analysis computations include the effects of planetary perturbations as well as the nongravitational accelerations introduced by the outgassing cometary nucleus. In 1980, excellent observing conditions and a close approach of comet Encke to the earth permit relatively small uncertainties in the cometary position errors and provide an excellent opportunity for a close flyby of a physically interesting comet.

Yeomans, D. K.↗

Geochemical and Microstructural Characterization of Shale Rock: A Workflow for Site Evaluation for Energy–Fluids Storage

Shales are a central component of petroleum systems, as source, seal, and unconventional reservoir rocks. Unlike traditional unconventional shale, a newly emerging Caney Shale play is regarded as an unconventional of unconventional shales (UUS), due to its high content of fine-grained materials, lower reservoir porosity, dominance of nanopores, and a scarcity of visible natural fractures. Other developed unconventional shales such as the Woodford and Barnett have larger average pore size, higher porosity, and extensive natural fractures at core scale that contribute to reservoir quality. In this work, the Caney Shale was cored in entirety to characterize its interbedded ductile and reservoir intervals and establish criteria for their recognition. Representative ductile and reservoir intervals known as D2 and R3, respectively, were selected for detailed analysis including variations in elemental composition, mineralogy, facies, and the presence of natural fractures at well and core scales using X-ray fluorescence, X-ray diffraction, and thin section and core description. Characteristics of microstructure and microgeochemistry at nano- and microscales are compared using field emission scanning electron microscopy with energy dispersive spectroscopy and lowpressure nitrogen adsorption isotherms with fractal dimension analysis. The ductile (detrital clay-rich) member D2 is characterized by higher concentrations of Ti and Al and lower Si, while the reservoir R3 (possibly biogenic silica-accumulated) is characterized by lower Ti and Al and higher Si. Eight mixed carbonate–siliciclastic facies are recognized, and R3 shows a higher heterogeneity of facies stacking and average fracture abundance than D2. Further, R3 shows a more microscopically heterogeneous fabric/texture of matrix and a higher microporosity than D2 that has a higher pore surface heterogeneity. A fundamental understanding of the compositional and microstructural characteristics of UUS and further ductile/reservoir intervals will allow for a better assessment of reservoir quality, more effective production of hydrocarbons, and optimized selection of safe caprocks in carbon sequestration and subsurface hydrogen storage.

58 GEOSCIENCES↗

A Bayesian Meta-Analysis of the Effect of Alcohol Use on HCV-Treatment Outcomes with a Comparison of Resampling Methods to Assess Uncertainty in Parameter Estimates.

There is mounting evidence that alcohol use is significantly linked to lower HCV treatment response rates in interferon-based therapies, though some of the evidence is conflicting. Furthermore, although health care providers recommend reducing or abstaining from alcohol use prior to treatment, many patients do not succeed in doing so. The goal of this meta-analysis was to systematically review and summarize the Englishlanguage literature up through January 30, 2015 regarding the relationship between alcohol use and HCV treatment outcomes, among patients who were not required to abstain from alcohol use in order to receive treatment. Seven pertinent articles studying 1,751 HCV-infected patients were identified. Log-ORs of HCV treatment response for heavy alcohol use and light alcohol use were calculated and compared. We employed a hierarchical Bayesian meta-analytic model to accommodate the small sample size. The summary estimate for the log-OR of HCV treatment response was -0.775 with a 95% credible interval of (-1.397, -0.236). The results of the Bayesian meta-analysis are slightly more conservative compared to those obtained from a boot-strapped, random effects model. We found evidence of heterogeneity (Q = 14.489, p = 0.025), accounting for 60.28% of the variation among log-ORs. Meta-regression to capture the sources of this heterogeneity did not identify any of the covariates investigated as significant. This meta-analysis confirms that heavy alcohol use is associated with decreased HCV treatment response compared to lighter levels of alcohol use. Further research is required to characterize the mechanism by which alcohol use affects HCV treatment response.

alcohol↗

Intensity-Modulated Radiotherapy Reduces Gastrointestinal Toxicity in Patients Treated With Androgen Deprivation Therapy for Prostate Cancer

Purpose: Androgen deprivation therapy (AD) has been shown to increase late Grade 2 or greater rectal toxicity when used concurrently with three-dimensional conformal radiotherapy (3D-CRT). Intensity-modulated radiotherapy (IMRT) has the potential to reduce toxicity by limiting the radiation dose received by the bowel and bladder. The present study compared the genitourinary and gastrointestinal (GI) toxicity in men treated with 3D-CRT+AD vs. IMRT+AD. Methods and Materials: Between July 1992 and July 2004, 293 men underwent 3D-CRT (n = 170) or IMRT (n = 123) with concurrent AD (<6 months, n = 123; {>=}6 months, n = 170). The median radiation dose was 76 Gy for 3D-CRT (International Commission on Radiation Units and Measurements) and 76 Gy for IMRT (95% to the planning target volume). Toxicity was assessed by a patient symptom questionnaire that was completed at each visit and recorded using a Fox Chase Modified Late Effects Normal Tissue Task radiation morbidity scale. Results: The mean follow-up was 86 months (standard deviation, 29.3) for the 3D-CRT group and 40 months (standard deviation, 9.7) for the IMRT group. Acute GI toxicity (odds ratio, 4; 95% confidence interval, 1.6-11.7; p = .005) was significantly greater with 3D-CRT than with IMRT and was independent of the AD duration (i.e., <6 vs. {>=}6 months). The interval to the development of late GI toxicity was significantly longer in the IMRT group. The 5-year Kaplan-Meier estimate for Grade 2 or greater GI toxicity was 20% for 3D-CRT and 8% for IMRT (p = .01). On multivariate analysis, Grade 2 or greater late GI toxicity (hazard ratio, 2.1; 95% confidence interval, 1.1-4.3; p = .04) was more prevalent in the 3D-CRT patients. Conclusion: Compared with 3D-CRT, IMRT significantly decreased the acute and late GI toxicity in patients treated with AD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Benchmark Dose Analysis of DNA Damage Biomarker Responses Provides Compound Potency and Adverse Outcome Pathway Information for the Topoisomerase II Inhibitor Class of Compounds

Genetic toxicology data have traditionally been utilized for hazard identification to provide a binary call for a compound's risk. Recent advances in the scientific field, especially with the development of high‐throughput methods to quantify DNA damage, have influenced a change of approach in genotoxicity assessment. The in vitro MultiFlow® DNA Damage Assay is one such method which multiplexes γH2AX, p53, phospho‐histone H3 biomarkers into a single‐flow cytometric analysis (Bryce et al., [2016]: Environ Mol Mutagen 57:546–558). This assay was used to study human TK6 cells exposed to each of eight topoisomerase II poisons for 4 and 24 hr. Using PROAST v65.5, the Benchmark Dose approach was applied to the resulting flow cytometric datasets. With “compound” serving as covariate, all eight compounds were combined into a single analysis, per time point and endpoint. The resulting 90% confidence intervals, plotted in Log scale, were considered as the potency rank for the eight compounds. The in vitro MultiFlow data showed a maximum confidence interval span of 1Log, which indicates data of good quality. Patterns observed in the compound potency rank were scrutinized by using the expert rule‐based software program Derek Nexus, developed by Lhasa Limited. Compound sub‐classification and structural alerts were considered contributory to the potencies observed for the topoisomerase II poisons studied herein. The Topo II poison Adverse Outcome Pathway was evaluated with MultiFlow endpoints serving as Key Events. The step‐wise approach described herein can be considered as a foundation for risk assessment of compounds within a specific mode of action of interest. Environ. Mol. Mutagen. 2020. © 2020 Wiley Periodicals, Inc.

Wheeldon, Ryan P.↗

Prostate-Specific Antigen at 4 to 5 Years After Low-Dose-Rate Prostate Brachytherapy Is a Strong Predictor of Disease-Free Survival

Purpose: To determine (1) the prognostic utility of prostate-specific antigen (PSA) concentration at 45 to 60 months (48mPSA) after low-dose-rate prostate brachytherapy (LDR-PB); (2) the predictors of 48mPSA; and (3) the prognostic utility of directional trends between PSA levels at 24, 36, and 48 months after LDR-PB. Methods and Materials: Between 1998 and 2008, 2223 patients with low- and intermediate-risk prostate cancer received LDR-PB monotherapy. A cohort of 1434 of these patients was identified with a documented 48mPSA and no evidence of disease relapse prior to the 48mPSA. In addition, a subset of this cohort (n=585) was identified with ≥72 months of follow-up and documented PSA values at both 24 and 36 months after implantation. Results: Median follow-up time was 76 months. Eight-year Kaplan-Meier disease-free survival (DFS) rates were 100% vs 73.4% for patients with 48mPSA ≤0.2 vs those with >0.2 ng/mL; 99.1% versus 53.8% for a 48mPSA threshold of ≤0.4 versus >0.4 ng/mL, respectively; and 97.3% versus 0% for a threshold of ≤1.0 versus >1.0 ng/mL, respectively. On multivariate analysis, the only factor predictive of DFS was 48mPSA (P<.0001). On subset analysis (n=585), 29 patients had a PSA rise (defined as >0.2 ng/mL) between 24 and 36 months, 24 patients had a rise between 36 and 48 months, and 11 patients had rises over both intervals. Failure rates in these patients were 52%, 79%, and 100%, respectively. On multivariate analysis, initial PSA, androgen deprivation therapy, and dose to 90% of the prostate significantly correlated with 48mPSA but together accounted for only ∼5% of its total variance. Conclusions: The 48mPSA after LDR-PB is highly predictive of long-term DFS. Patients with 48mPSA ≤0.4 ng/mL had a <1% risk of disease relapse at 8 years, whereas all patients with 48mPSA >1.0 ng/mL relapsed. Consecutive PSA rises of >0.2 ng/mL from 24 to 36 months and from 36 to 48 months were also highly predictive of subsequent failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗