Search NASA⌕ Search

SEARCH · Search NASA

Results for “ion conductivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Nighttime observations of thunderstorm electrical activity from a high altitude airplane

Nocturnal thunderstorms were observed from above and features of cloud structure and lightning which are not generally visible from the ground are discussed. Most, lightning activity seems to be associated with clouds with strong convective cauliflower tops. In both of the storms lightning channels were visible in the clear air above the cloud. It is shown that substances produced by thunderstorm electrical discharges can be introduced directly into the stratosphere. The cause and nature of the discharges above the cloud are not clear. They may be produced by accumulations of space charge in the clear air above the cloud. The discharges may arise solely because of the intense electric fields produced by charges within the cloud. In the latter case the ions introduced by these discharges will increase the electrical conductivity of the air above the cloud and increase the conduction current that flows from the cloud to the electrosphere. More quantitative data at higher resolution may show significant spectral differences between cloud to ground and intracloud strokes. It is shown that electric field change data taken with an electric field change meter mounted in an airplane provide data on lightning discharges from above that are quite similar to those obtained from the ground in the past. The optical signals from dart leaders, from return strokes, and from continuing currents are recognizable, can be used to provide information on the fine structure of lightning, and can be used to distinguish between cloud to ground and intracloud flashes.

Brook, M.↗

Cold plasma distribution above a few thousand kilometers at high latitudes

Great advances with respect to the study of the earth's magnetosphere could be achieved in connection with the launch of the Dynamics Explorer (DE) 1 and 2 spacecraft. These advances were made possible partly because of the unique combination of coplanar orbits which simultaneously sample the low altitude ionospheric and atmospheric signature (DE-2) and the high altitude phenomena of the inner magnetosphere (DE-1). It was, thus, feasible to obtain new measurements of the coupling of plasmas and fields between these fundamentally important regions. One basic element of the coupling involves the interchange of low energy plasma between the ionosphere and magnetosphere. The flow characteristics of the low energy plasma are indicators of the magnetospheric and ionospheric electric fields which drive the current system. The Retarding Ion Mass Spectrometer (RIMS) instrument has been designed for conducting measurements regarding this plasma population. Attention is given to details regarding RIMS, an example RIMS orbit, plasma trough characteristics, and polar cap phenomena.

Chappell, C. R.↗

Nonvolatile Ionic Two-Terminal Memory Device

Conceptual solid-state memory device nonvolatile and erasable and has only two terminals. Proposed device based on two effects: thermal phase transition and reversible intercalation of ions. Transfer of sodium ions between source of ions and electrical switching element increases or decreases electrical conductance of element, turning switch "on" or "off". Used in digital computers and neural-network computers. In neural networks, many small, densely packed switches function as erasable, nonvolatile synaptic elements.

Williams, Roger M.↗

Gas chromatography/ion mobility spectrometry as a hyphenated technique for improved explosives detection and analysis

Ion Mobility Spectrometry (IMS) is currently being successfully applied to the problem of on-line trace detection of plastic and other explosives in airports and other facilities. The methods of sample retrieval primarily consist of batch sampling for particulate residue on a filter card for introduction into the IMS. The sample is desorbed into the IMS using air as the carrier and negative ions of the explosives are detected, some as an adduct with a reagent ion such as Cl(-). Based on studies and tests conducted by different airport authorities, this method seems to work well for low vapor pressure explosives such as RDX and PETN, as well as TNT that are highly adsorptive and can be found in nanogram quantities on contaminated surfaces. Recently, the changing terrorist threat and the adoption of new marking agents for plastic explosives has meant that the sample introduction and analysis capabilities of the IMS must be enhanced in order to keep up with other detector developments. The IMS has sufficient analytical resolution for a few threat compounds but the IMS Plasmogram becomes increasingly more difficult to interpret when the sample mixture gets more complex.

Mercado, AL↗

Laboratory Measurements of the X-ray Line Emission from Neon-like Fe XVII

We have conducted a systematic study of the dominant x-ray line emission from Fe XVII. These studies include relative line intensities in the optically thin limit, intensities in the presence of radiation from satellite lines from lower charge states of iron, and the absolute excitation cross sections of some of the strongest lines. These measurements were conducted at the Lawrence Livermore National Laboratory electron beam ion trap facility using crystal spectrometers and a NASA-Goddard Space Flight Center microcalorimeter array.

Brown, G. V.↗

Preliminary Investigation on Battery Sizing Investigation for Thrust Vector Control on Ares I and Ares V Launch Vehicles

An investigation into the merits of battery powered Electro Hydrostatic Actuation (EHA) for Thrust Vector Control (TVC) of the Ares I and Ares V launch vehicles is described. A top level trade study was conducted to ascertain the technical merits of lithium-ion (Li-ion) and thermal battery performance to determine the preferred choice of an energy storage system chemistry that provides high power discharge capability for a relatively short duration.

Miller, Thomas B.↗

Battery Failure Databank

The Battery Failure Databank contains thermal runaway results gathered from nearly 300 small format fractional thermal runaway calorimetry (S-FTRC) experiments. A majority of these experiments were conducted at synchrotron facilities where high-speed x-ray videography was conducted of the cell while tested inside of the S-FTRC. The databank is a two-component system which consists of a Microsoft ExcelTM spreadsheet which provides S-FTRC results in tabular format and a radiographic video library containing the high-speed x-ray videos. Overall, the databank provides thermal results from S-FTRC experiments conducted on a mixture of commercially available lithium-ion (Li-ion) cells and specialized Li-ion test cells with varying cell format (18650, 21700, and D-cell) and trigger mechanism (heaters, heaters plus internal short circuiting device, and nail penetration). The radiography video component provides insight into the initiation and propagation of TR in the cells, in addition to consequences of TR measured by the FTRC. Fractions of mass ejected for the cell types are separated into regimes based on the different failure modes of the cells, such as purely venting, partial ejection, and total ejection. With knowledge of the rate and characterization of the internal degradation of the cells during TR, and the amounts of mass ejected and unrecovered, the extent of TR, and therefore the mitigation of TR, is revealed relative to cell types and failure modes.

Lithium-ion battery↗

Deep Space Atomic Clock Technology Demonstration Mission Results

The Deep Space Atomic Clock (DSAC), a NASA Technology Demonstration Mission, was launched into low-Earth orbit on June 25, 2019 as a hosted payload aboard General Atomics’ Orbital Test Bed (OTB) spacecraft. The DSAC mission has been conducting a two-year demonstration of a mercury ion atomic clock to characterize its space-based performance and to validate its utility for deep space navigation and radio science. Analysis of the collected data using JPL’s GIPSY-OASIS software has shown DSAC’s AD at one-day to be near 310-15; much better than required AD of 210-14. Such low spacecraft clock errors will enable one-way radiometric tracking data with precision equivalent to or better than current-day two way tracking data, allowing a shift to a more efficient and flexible one-way deep space navigation architecture. To verify this, an analog deep space navigation experiment was performed using JPL’s operational navigation software (Monte). The experiment recovered orbit solutions with reduced data sets and geometric variations that are more representative of deep space missions, and showed that orbit determination using DSAC derived data is on par with more traditional two-way datatypes. As a technology demonstrator, DSAC’s development focus has been on maturing the mercury ion trap clock technology rather than achieving the smallest size, weight, and power (SWaP). Over the course of DSAC’s development the project has identified numerous improvements that could be made to significantly reduce SWaP for DSAC’s next version. Indeed, DSAC-2 was recently selected by NASA for further demonstration on the VERITAS mission to Venus. This work will review the DSAC technology, mission, and results from its two-year mission.

Wang, Rabi↗

Spacecraft Water Impurity Monitor, a System for Water Quality Analysis on Exploration Missions Beyond Low Earth Orbit

Exploration missions beyond low-earth-orbit (LEO) will require advanced instrumentation to monitor water quality. Traveling beyond LEO means the transfer of water samples to an Earth-based laboratory for detailed analysis is not feasible. Detailed analysis of water composition during exploration is still necessary, because having the capability to determine the specific organic chemical causing a change in total organic carbon (TOC) or the specific metal or ionic species causing a change in conductivity has the potential to inform the crew health and system management decisions. On a new vehicle such as a lunar or Mars surface habitat or a Mars transit vehicle, finding “new” impurities not seen on ISS should be expected. The key is to identify the impurity so the correct action can be taken. On ISS we can measure TOC, conductivity, and other physical properties but do not have the capability for detailed analysis using vehicle instrumentation. This is acceptable because ISS can send samples down to Earth for further analysis and obtain the detailed composition. The Spacecraft Water Impurity Monitor (SWIM) will provide detailed water quality analysis for missions in which sample down mass is not available. SWIM is a system comprising organic and inorganic analysis modules. For organic chemicals, a gas chromatograph mass spectrometer (GCMS) detects and identifies organic impurities. For inorganic species, a capillary electrophoresis capacitively coupled contactless conductivity detection (CE-C4D) system as well as ion specific electrodes detect and identify metal ions and other inorganic salts / acids. The SWIM technology demonstration project has completed a System Requirements Review (SRR) to finalize detection requirements and is currently working to refine vehicle interface requirements for a future technology demonstration. The project also has begun preliminary flight design activities for the core analyzers in the instrument suite.

Water Monitoring↗

Spacecraft Water Impurity Monitor, a System for Water Quality Analysis on Exploration Missions Beyond Low Earth Orbit

Exploration missions beyond low-earth-orbit (LEO) will require advanced instrumentation to monitor water quality. Traveling beyond LEO means the transfer of water samples to an Earth-based laboratory for detailed analysis is not feasible. Detailed analysis of water composition during exploration is still necessary, because having the capability to determine the specific organic chemical causing a change in total organic carbon (TOC) or the specific metal or ionic species causing a change in conductivity has the potential to inform the crew health and system management decisions. On a new vehicle such as a lunar or Mars surface habitat or a Mars transit vehicle, finding “new” impurities not seen on ISS should be expected. The key is to identify the impurity so the correct action can be taken. On ISS we can measure TOC, conductivity, and other physical properties but do not have the capability for detailed analysis using vehicle instrumentation. This is acceptable because ISS can send samples down to Earth for further analysis and obtain the detailed composition. The Spacecraft Water Impurity Monitor (SWIM) will provide detailed water quality analysis for missions in which sample down mass is not available. SWIM is a system comprising organic and inorganic analysis modules. For organic chemicals, a gas chromatograph mass spectrometer (GCMS) detects and identifies organic impurities. For inorganic species, a capillary electrophoresis capacitively coupled contactless conductivity detection (CE-C4D) system as well as ion specific electrodes detect and identify metal ions and other inorganic salts / acids. The SWIM technology demonstration project has completed a System Requirements Review (SRR) to finalize detection requirements and is currently working to refine vehicle interface requirements for a future technology demonstration. The project also has begun preliminary flight design activities for the core analyzers in the instrument suite.

Water Monitoring↗

Effects of thermospheric motions on the polar wind - A time-dependent numerical study

This paper presents the results of a numerical study investigating the effects of low-altitude short-duration plasma heating episodes (such as horizontal frictional heating) on transient heavy ion outflows from the polar ionosphere using a time-dependent model. In a previous set of calculations, where the effects of high-altitude transient heat sources were investigated, the low-altitude neutral atmosphere (z less than 800 km) acted as a very efficient heat sink, absorbing most of the energy conducted to this region and thus preventing large differences between the ion and neutral temperatures. One purpose of the present study was to investigate whether realistic, specified low-altitude frictional heating rates, based on published experimental data, can result in elevated ion temperatures and lift a part of the heavy ion population over the gravitational barrier before the extra energy is lost to the neutral atmosphere. In these model calculations the specified heating generated an upflowing O(+) disturbance (with a normalized peak flux of about 100 million/sq cm per sec) moving upward along the open magnetic field line with a velocity of about 2 km/s. The spatial extent of the disturbance was approximately equal to the disturbance velocity times the duration of the heat source. The model results provide a possible mechanism to explain recent European Incoherent Scatter observations of high-latitude O(+) upwellings.

Gombosi, T. I.↗

The Analysis of the Patterns of Radiation-Induced DNA Damage Foci by a Stochastic Monte Carlo Model of DNA Double Strand Breaks Induction by Heavy Ions and Image Segmentation Software

To create a generalized mechanistic model of DNA damage in human cells that will generate analytical and image data corresponding to experimentally observed DNA damage foci and will help to improve the experimental foci yields by simulating spatial foci patterns and resolving problems with quantitative image analysis. Material and Methods: The analysis of patterns of RIFs (radiation-induced foci) produced by low- and high-LET (linear energy transfer) radiation was conducted by using a Monte Carlo model that combines the heavy ion track structure with characteristics of the human genome on the level of chromosomes. The foci patterns were also simulated in the maximum projection plane for flat nuclei. Some data analysis was done with the help of image segmentation software that identifies individual classes of RIFs and colocolized RIFs, which is of importance to some experimental assays that assign DNA damage a dual phosphorescent signal. Results: The model predicts the spatial and genomic distributions of DNA DSBs (double strand breaks) and associated RIFs in a human cell nucleus for a particular dose of either low- or high-LET radiation. We used the model to do analyses for different irradiation scenarios. In the beam-parallel-to-the-disk-of-a-flattened-nucleus scenario we found that the foci appeared to be merged due to their high density, while, in the perpendicular-beam scenario, the foci appeared as one bright spot per hit. The statistics and spatial distribution of regions of densely arranged foci, termed DNA foci chains, were predicted numerically using this model. Another analysis was done to evaluate the number of ion hits per nucleus, which were visible from streaks of closely located foci. In another analysis, our image segmentaiton software determined foci yields directly from images with single-class or colocolized foci. Conclusions: We showed that DSB clustering needs to be taken into account to determine the true DNA damage foci yield, which helps to determine the DSB yield. Using the model analysis, a researcher can refine the DSB yield per nucleus per particle. We showed that purely geometric artifacts, present in the experimental images, can be analytically resolved with the model, and that the quantization of track hits and DSB yields can be provided to the experimentalists who use enumeration of radiation-induced foci in immunofluorescence experiments using proteins that detect DNA damage. An automated image segmentaiton software can prove useful in a faster and more precise object counting for colocolized foci images.

Ponomarev, Artem↗

The energetics of the ionosphere of Venus - A preliminary model based on Pioneer Venus observations

A model of the energy balance of the dayside ionosphere of Venus is presented. The coupled energy equations for electrons and ions are solved numerically and the calculated temperatures are compared with temperatures measured by instruments on the Pioneer Venus Orbiter. Neutral and ion density profiles consistent with those measured by various Pioneer Venus experiments are used in the model. It was found that using standard EUV sources and thermal conductivities the calculations produce temperatures that are much lower than the measured ones. Consequently, further calculations were performed in which (1) the thermal conductivities were inhibited by means of an almost horizontal magnetic field and/or (2) heat inflow into both the electron and ion gas at the top of the ionosphere was assumed due to the solar wind interaction. It was found that the calculated and measured temperatures were in reasonably good agreement if the thermal conductivities were inhibited by a near horizontal field of about 10 gammas and if the electron and ion heat fluxes were taken to be 4 x 10 to the 9th eV/sq cm/sec and 10 to the 7th eV/sq cm/sec, respectively.

Cravens, T. E.↗

A magnetohydrodynamical model of the inner coma of Comet Halley

The magnetometer onboard the Giotto spacecraft observed a diamagnetic cavity surrounding the nucleus of Comet Halley. The location of the boundary of this diamagnetic cavity is determined by a balance between an inward magnetic pressure gradient force and an outward ion-neutral drag force, associated with collisions between the outwardly flowing neutrals and the stagnated ions. A one-dimensional time-dependent MHD model has been developed for the inner coma of Comet Halley, and includes ion-neutral collisions, photochemical production and loss of plasma, and finite conductivity. This model is used to investigate the plasma dynamics in the vicinity of the diamagnetic cavity boundary surface. A narrow transition layer with enhanced plasma density is shown to exist just inside the boundary, although a full understanding of this layer will require a two- or three-dimensional MHD model. The flux of cometary ions into this shocklike layer is removed by electron-ion recombination. The thickness of this layer is determined by the Mach number of the incident flow.

Cravens, T. E.↗

Response of a metal-oxide-semiconductor field-effect transistor to a cosmic-ray ion track

A cosmic-ray ion track passing perpendicularly through the oxide layer of an enhancement-mode metal-oxide-semiconductor field-effect transistor (MOSFET) forms a conducting path, the resistance of which is proportional to the stopping power of the cosmic ion and independent of the cross-sectional area of the ion track. The voltage across the oxide capacitance may drop below the threshold voltage if the gate bias is sufficiently low or if the external resistance in the gate-source circuit is sufficiently high. The first of a pair of MOSFETs forming a flip-flop circuit may thus be turned off, and the second transitor may turn on, providing it has a sufficiently short delay time, thereby completing a single-event upset.

Benumof, Reuben↗

Experimental measurement of the plasma conductivity of Z93 and Z93P thermal control paint

Two samples each of Z93 and Z93P thermal control paint were exposed to a simulated space environment in a plasma chamber. The samples were biased through a series of voltages ranging from -200 volts to +300 volts and electron and ion currents measured. By comparing the currents to those of pure metal samples of the same size and shape, the conductivity of the samples was calculated. Measured conductivity was dependent on the bias potential in all cases. For Z93P, conductivity was approximately constant over much of the bias range and we find a value of 0.5 micro-mhos per square meter for both electron and ion current. For Z93, the dependence on bias was much more pronounced but conductivity can be said to be approximately one order of magnitude larger. In addition to presenting these results, this report documents all of the experimental data as well as the statistical analyses performed.

Hillard, G. Barry↗

Administrative Report on Training Awards

During the tenure of this award, the recipient (David Harker) conducted areas of research which resulted in the award of a doctorate degree (August 1999) from the University of Wyoming. The primary science activity was investigation of silicate dust mineralogy in comets, particularly comet C/1995 O1 (Hale-Bopp). Determination of the dust mineralogy permits us to address an important astrophysical question of relevance to the origins and evolution of solar systems, "Do comets contain relic interstellar dust grains? Since, comets represent the frozen reservoirs of primitive proto-solar dust and ice, we can gain insight into the problem of understanding the formation of protoplanetesimals in the. early solar nebula. Mid-infrared spectrophotometry (7 - 14 micron, R approx. = 180 - 360) of Hale-Bopp was obtained with the NASA/Ames HIFOGS at four distinct epochs pre- and post- perihelion ion from 1996 October through 1997 June. These observations were conducted at the Wyoming Infrared Observatory and the NASA Infrared Telescope Facility, and were supported by funds from this training grant. The emission at mid-IR wavelengths in cometary comae arises from carbon grains, and small silicate grains which produce resonance features. Hale-Bopp had the strongest silicate feature observed from any comet to date. Theoretical calculations utilizing Mie Scattering Theory were employed to construct Synthetic cometary spectra to fit with the observed HIFOGS 10 microns spectral feature of Hale-Bopp. Our analysis suggests that the observed spectra can be modeled with the Hanner grain size distribution peaked at alpha((sub p) = 0.2 microns of fractal porous grains with porosity parameter D = 2.5. This model spectrum also fits photometry points in the 3 - 5 microns region. Comparison with the ISO SWS spectrum of Hale-Bopp obtained 1996 October reveals that the crystalline olivine grains must be at it temperature hotter than computed from Mie theory.

Woodward, Charles E.↗

A proof of concept investigation: A unique mobility spectrometer for In Situ diagnostics of positive and negative ion distributions in the mesosphere and lower ionosphere

We have carried out a proof-of-concept development and test effort that not only promises the reduction of parasitic effects of surface contamination (therefore increasing the integrity of 'in situ' measurements in the 60-130 km regime), but promises a uniquely expanded measurement set that includes electron densities, plasma conductivities, charged-particle mobilities, and mass discrimination of positive and negative ion distributions throughout the continuum to free-molecular-flow regimes. Three different sensor configurations were designed, built and tested, along with specialized driving voltage, electrometer and channeltron control electronics. The individual systems were tested in a variety of simulated space environments ranging from pressures near the continuum limit of 100 mTorr to the collisionless regime at 10(exp -6) Torr. Swept modes were initially employed to better understand ion optics and ion 'beam' losses to end walls and to control electrodes. This swept mode also helped better understand and mitigate the influences of secondary electrons on the overall performance of the PIMS design concept. Final results demonstrated the utility of the concept in dominant single-ion plasma environments. Accumulated information, including theoretical concepts and laboratory data, suggest that multi-ion diagnostics are fully within the instrument capabilities and that cold plasma tests with minimized pre-aperture sheath acceleration are the key ingredients to multi-ion success.

Szuszczewicz, Edward P.↗