At least 451 records · Page 25

Chemical release module facility

The chemical release module provides the capability to conduct: (1) thermite based metal vapor releases; (2) pressurized gas releases; (3) dispersed liquid releases; (4) shaped charge releases from ejected submodules; and (5) diagnostic measurements with pi supplied instruments. It also provides a basic R-F and electrical system for: (1) receiving and executing commands; (2) telemetering housekeeping data; (3) tracking; (4) monitoring housekeeping and control units; and (5) ultrasafe disarming and control monitoring.

Reasoner, D. L.↗

Gas Chromatic Mass Spectrometer

Gas chromatograph/mass spectrometer (GC/MS) used to measure and identify combustion species present in trace concentration. Advanced extractive diagnostic method measures to parts per billion (PPB), as well as differentiates between different types of hydrocarbons. Applicable for petrochemical, waste incinerator, diesel transporation, and electric utility companies in accurately monitoring types of hydrocarbon emissions generated by fuel combustion, in order to meet stricter environmental requirements. Other potential applications include manufacturing processes requiring precise detection of toxic gaseous chemicals, biomedical applications requiring precise identification of accumulative gaseous species, and gas utility operations requiring high-sensitivity leak detection.

Wey, Chowen↗

Quantitative Measurement of Oxygen in Microgravity Combustion

A low-gravity environment, in space or in ground-based facilities such as drop towers, provides a unique setting for studying combustion mechanisms. Understanding the physical phenomena controlling the ignition and spread of flames in microgravity has importance for space safety as well as for better characterization of dynamical and chemical combustion processes which are normally masked by buoyancy and other gravity-related effects. Due to restrictions associated with performing measurements in reduced gravity, diagnostic methods which have been applied to microgravity combustion studies have generally been limited to capture of flame emissions on film or video, laser Schlieren imaging and (intrusive) temperature measurements using thermocouples. Given the development of detailed theoretical models, more sophisticated diagnostic methods are needed to provide the kind of quantitative data necessary to characterize the properties of microgravity combustion processes as well as provide accurate feedback to improve the predictive capabilities of the models. When the demands of space flight are considered, the need for improved diagnostic systems which are rugged, compact, reliable, and operate at low power becomes apparent. The objective of this research is twofold. First, we want to develop a better understanding of the relative roles of diffusion and reaction of oxygen in microgravity combustion. As the primary oxidizer species, oxygen plays a major role in controlling the observed properties of flames, including flame front speed (in solid or liquid flames), extinguishment characteristics, flame size and flame temperature. The second objective is to develop better diagnostics based on diode laser absorption which can be of real value in both microgravity combustion research and as a sensor on-board Spacelab as either an air quality monitor or as part of a fire detection system. In our prior microgravity work, an eight line-of-sight fiber optic system measured water vapor mole fractions in the NASA Lewis 2.2-sec Drop Tower. In that system, the laser and all electronics resided at the top of the drop tower and was connected via a fiber optic cable to the rig, on which a 'pitch and catch' set of fiber collimating lenses were used to transmit the laser beam across a jet diffusion flame. This system required eight independent detection/demodulation units and had poor spatial resolution. This research builds on this earlier work, resulting in an improved capability for quantitative, nonintrusive measurement of major combustion species. A vertical cavity surface-emitting diode laser (VCSEL) and a continuous spatial scanning method permit the measurement of temporal and spatial profiles of the concentrations and temperatures of molecular oxygen. High detection sensitivity is achieved with wavelength modulation spectroscopy (WMS). One-g experiments are performed using a slot diffusion flame. Microgravity measurements on a solid fuel (cellulose sheet) system are planned for the NASA Lewis 2.2-second Drop Tower Facility.

Silver, Joel A.↗

Ion Acceleration in Solar Flares

Solar flares are among the most energetic and interesting phenomena in the Solar system, releasing up to 1032 ergs of energy on timescales of several tens of seconds to several tens of minutes. Much of this energy is in the form of suprathermal electrons and ions, which remain trapped at the Sun and produce a wide variety of radiations, as well as escape into interplanetary space, where they can be directly observed. The radiation from trapped particles consists in general of (1) continuum emission; (2) narrow gamma-ray nuclear deexcitation lines; and (3) high-energy neutrons observed in space or by ground-based neutron monitors. The particles that escape into space consist of both electrons and ions, which often have compositions quite different than that of the ambient solar atmosphere. Flares thus present many diagnostics of the particle acceleration mechanism(s), the identification of which is the ultimate goal of flare research. Moreover, flares in fact offer the only opportunity in astrophysics to study the simultaneous energization of both electrons and ions. Hopefully, an understanding of flares with their wealth of diagnostic data will lead to a better understanding of particle acceleration at other sites in the Universe. It is now generally accepted that flares are roughly divided into two classes: impulsive and gradual. Gradual events are large, occur high in the corona, have long-duration soft and hard X-rays and gamma rays, are electron poor, are associated with Type II radio emission and coronal mass ejections (CMEs), and produce energetic ions with coronal abundance ratios. Impulsive events are more compact, occur lower in the corona, produce short-duration radiation, and exhibit dramatic abundance enhancements in the energetic ions. Their He-3/He-4 ratio is - 1, which is a huge increase over the coronal value of about 5 x 10(exp -4), and they also posses smaller but still significant enhancements of Ne, Mg, Si, and Fe relative to He-4, C, N, and O. Specifically, above about 1 MeV nucleon(exp -1), the ratio of Fe to O is about 8 times larger than in the corona or in gradual flares, while the ratio of Ne, Mg, and Si to O is about 3 times higher; He-4, C, N, and 0 are not enchanced with respect to each other. In addition to these elemental enhancements, Ne and Mg have isotopic enhancements as well. The general scenario that has emerged from these (and other) observations is that energetic particles in gradual events are accelerated by a CME-driven shock, while those particles in impulsive events are accelerated by another mechanism(s).

Miller, James A.↗

Low cost environmental sensors for Spaceflight : NMP Space Environmental Monitor (SEM) requirements

An outstanding problem in spaceflight is the lack of adequate sensors for monitoring the space environment and its effects on engineering systems. By adequate, we mean low cost in terms of mission impact (e.g., low price, low mass/size, low power, low data rate, and low design impact). The New Millennium Program (NMP) is investigating the development of such a low-cost Space Environmental Monitor (SEM) package for inclusion on its technology validation flights. This effort follows from the need by NMP to characterize the space environment during testing so that potential users can extrapolate the test results to end-use conditions. The immediate objective of this effort is to develop a small diagnostic sensor package that could be obtained from commercial sources. Environments being considered are: contamination, atomic oxygen, ionizing radiation, cosmic radiation, EMI, and temperature. This talk describes the requirements and rational for selecting these environments and reviews a preliminary design that includes a micro-controller data logger with data storage and interfaces to the sensors and spacecraft. If successful, such a sensor package could be the basis of a unique, long term program for monitoring the effects of the space environment on spacecraft systems.

Galileo↗

LETS: Lunar Environments Test System

The Environmental Effects Branch (EM50) at the Marshall Space Flight Center has developed a unique capability within the agency, namely the Lunar Environment Test System (LETS). LETS is a cryo-pumped vacuum chamber facility capable of high vacuum (10-7 Torr). LETS is a cylindrical chamber, 30 in. (0.8 m) diameter by 48 in. (1.2 m) long thermally controlled vacuum system. The chamber is equipped with a full array of radiation sources including vacuum ultraviolet, electron, and proton radiation. The unique feature of LETS is that it contains a large lunar simulant bed (18 in. x 40 in. x 6 in.) holding 75 kg of JSC-1a simulant while operating at a vacuum of 10-7 Torr. This facility allows three applications: 1) to study the charging, levitation and migration of dust particles, 2) to simulate the radiation environment on the lunar surface, and 3) to electrically charge the lunar simulant enhancing the attraction and adhesion of dust particles to test articles more closely simulating the lunar surface dust environment. LETS has numerous diagnostic instruments including TREK electrostatic probes, residual gas analyzer (RGA), temperature controlled quartz crystal microbalance (TQCM), and particle imaging velocimeter (PIV). Finally, LETS uses continuous Labview data acquisition for computer monitoring and system control.

Vaughn, Jason A.↗

Low Cost Environmental Sensors for Spaceflight: NMP Space Environmental Monitor (SEM) Requirements

An outstanding problem in spaceflight is the lack of adequate sensors for monitoring the space environment and its effects on engineering systems. By adequate, we mean low cost in terms of mission impact (e.g., low price, low mass/size, low power, low data rate, and low design impact). The New Millennium Program (NMP) is investigating the development of such a low-cost Space Environmental Monitor (SEM) package for inclusion on its technology validation flights. This effort follows from the need by NMP to characterize the space environment during testing so that potential users can extrapolate the test results to end-use conditions. The immediate objective of this effort is to develop a small diagnostic sensor package that could be obtained from commercial sources. Environments being considered are: contamination, atomic oxygen, ionizing radiation, cosmic radiation, EMI, and temperature. This talk describes the requirements and rational for selecting these environments and reviews a preliminary design that includes a micro-controller data logger with data storage and interfaces to the sensors and spacecraft. If successful, such a sensor package could be the basis of a unique, long term program for monitoring the effects of the space environment on spacecraft systems.

New Millennium Program (NMP)↗

Spaceflight Associated Neuro-ocular Syndrome (SANS): Clinical Update

Spaceflight Associated Neuro-ocular Syndrome (SANS) is a condition unique to long-duration spaceflight, with an unclear pathogenesis and pathophysiology, and no perfect terrestrial analog. Approximately 69% of long duration astronauts present with the earliest indications of SANS, which is defined as development of one or more of the following new signs in at least one eye during or immediately after spaceflight: 1) optic disc edema (ODE; represented by an increase of ≥ 20 microns in peripapillary total retinal thickness [ΔTRT]); 2) chorioretinal folds; 3) globe flattening; and 4) excessive shift in refractive error (≥ +0.75D). Each of these signs presents potential risk to a crewmember’s vision and mission effectiveness, with ODE posing the highest risk overall. It is not yet known what severity and/or duration of signs represents the “pathological” threshold of SANS, or how this threshold will eventually influence the SANS case definition. Brain anatomical changes also occur during long-duration spaceflight and are being monitored in the astronaut population; however, these changes have not yet been associated with functional decrements or with SANS. An update will be provided on the latest SANS clinical analyses, diagnostic technologies, and program initiatives.

TJ Brunstetter↗

SPACEFLIGHT ASSOCIATED NEURO-OCULAR SYNDROME (SANS): 2023 CLINICAL UPDATE

INTRODUCTION Spaceflight Associated Neuro-ocular Syndrome (SANS) is a condition unique to long-duration spaceflight, with an unclear pathogenesis and pathophysiology, and no perfect terrestrial analog. Approximately 66% of long duration spaceflight (LDSF) astronauts present with the earliest indication of SANS, which is defined as development of any of the following signs in at least one eye during or immediately following spaceflight: 1) optic disc edema (ODE; represented by an increase of ≥ 20 microns in peripapillary total retinal thickness [ΔTRT]); 2) chorioretinal folds; 3) globe flattening; and 4) excessive shift in refractive error (≥ +0.75D). Each of these signs presents potential risk to a crewmember’s vision and mission effectiveness, with ODE posing the highest risk overall. It is not yet known what severity and/or duration of these signs might lead to acute or permanent impacts to ocular anatomy or visual performance. Brain anatomical changes also occur during long-duration spaceflight and are being monitored in the astronaut population; however, these changes have not yet been associated with functional decrements or with SANS. An update will be provided on the latest SANS clinical analyses, diagnostics, and program initiatives. METHODS Data were obtained from clinical records and SANS subject matter experts (SMEs) to compile a SANS clinical update. Areas of interest include: 1) prevalence of SANS signs, 2) defining clinical thresholds for SANS, and 3) an overview of current and planned SANS clinical efforts. DISCUSSION SANS Sign Prevalence: Analysis at the time of this abstract submission indicates that the approximate prevalence of primary SANS findings in USOS LDSF crewmembers is: 64% for ODE (≥ 20-micron ΔTRT), 15% for chorioretinal folds, 26% for globe flattening, and 14% for hyperopic shifts in refractive error (≥ +0.75D). Clinical Thresholds:  The Earliest Indication of SANS was presented publicly for the first time at the 2020 NASA Human Research Program Investigators’ Workshop. See definition in Introduction section (above).  Clinically Concerning SANS – Development of any of the following signs during or immediately following spaceflight: 1) ODE (≥ 55-micron ΔTRT* and/or Frisèn grade ≥1*), 2) sharp chorioretinal folds in the vicinity of the macula, or 3) moderate globe flattening.  Pathological SANS with an Acute Functional Impact – Development of any of the following signs/symptoms during or immediately following spaceflight: 1) visual field loss (e.g., enlarged blindspot), 2) distorted centralvision, or 3) shift in refractive error beyond power of available correction (e.g., “space anticipation glasses”).  Pathological SANS affecting Long-Term Health – Development of any of the following signs/symptoms during or following spaceflight: 1) permanent visual field loss, 2) reduced retinal nerve fiber layer (RNFL) thickness, 3) permanently distorted central vision, 4) atrophy of retinal pigment epithelium (RPE) or photoreceptors, or 5) choroidal neovascularization. Current & Planned Clinical Efforts (accurate at time of abstract submission): All SANS diagnostic hardware are performing nominally onboard the International Space Station: vision screening, fundoscope, optical coherence tomography (OCT) device, ultrasound, and tonometer. The Goggle-Based Visual Field (GBVF) device is nearing completion of its clinical validation study at Ohio State University and is planned for parabolic flight testing in fiscal year 2023 (FY23); pending positive results, this sequence may pave the way towards an ISS technology demonstration in FY24.

T J Brunstetter↗

Study of fluid flow by charged particles

Analytical and experimental effort explores possibility of using charged particles as diagnostic tool in study of fluid flows. Test program involved right circular cylinder and airfoil located in large wind tunnel; ions were injected into flow and resulting currents at surfaces were monitored.

Deluca, M.↗

An expert system approach to turbopump health monitoring

A preliminary report is presented on the development of a system for monitoring the High Pressure Oxidizer Turbopump of the SSME. System development will proceed by defining the degradation mechanism of the turbopump, identifying those conventional and advanced sensor measurements that can monitor these mechanisms, and determining the digital processing requirements for these measurements. Once the failures and associated measurements have been defined, an expert system will be developed that can make both diagnostic and prognostic inferences about the condition and performance of the turbopump.

Perry, John G.↗

Fault Management Technology Maturation for NASA's Constellation Program

This slide presentation reviews the maturation of fault management technology in preparation for the Constellation Program. There is a review of the Space Shuttle Main Engine (SSME) and a discussion of a couple of incidents with the shuttle main engine and tanking that indicated the necessity for predictive maintenance. Included is a review of the planned Ares I-X Ground Diagnostic Prototype (GDP) and further information about detection and isolation of faults using Testability Engineering and Maintenance System (TEAMS). Another system that being readied for use that detects anomalies, the Inductive Monitoring System (IMS). The IMS automatically learns how the system behaves and alerts operations it the current behavior is anomalous. The comparison of STS-83 and STS-107 (i.e., the Columbia accident) is shown as an example of the anomaly detection capabilities.

Waterman, Robert D.↗

How Cities Breathe: Ground-Referenced, Airborne Hyperspectral Imaging Precursor Measurements To Space-Based Monitoring

Methane's (CH4) large global warming potential (Shindell et al., 2012) and likely increasing future emissions due to global warming feedbacks emphasize its importance to anthropogenic greenhouse warming (IPCC, 2007). Furthermore, CH4 regulation has far greater near-term climate change mitigation potential versus carbon dioxide CO2, the other major anthropogenic Greenhouse Gas (GHG) (Shindell et al., 2009). Uncertainties in CH4 budgets arise from the poor state of knowledge of CH4 sources - in part from a lack of sufficiently accurate assessments of the temporal and spatial emissions and controlling factors of highly variable anthropogenic and natural CH4 surface fluxes (IPCC, 2007) and the lack of global-scale (satellite) data at sufficiently high spatial resolution to resolve sources. Many important methane (and other trace gases) sources arise from urban and mega-urban landscapes where anthropogenic activities are centered - most of humanity lives in urban areas. Studying these complex landscape tapestries is challenged by a wide and varied range of activities at small spatial scale, and difficulty in obtaining up-to-date landuse data in the developed world - a key desire of policy makers towards development of effective regulations. In the developing world, challenges are multiplied with additional political access challenges. As high spatial resolution satellite and airborne data has become available, activity mapping applications have blossomed - i.e., Google maps; however, tap a minute fraction of remote sensing capabilities due to limited (three band) spectral information. Next generation approaches that incorporate high spatial resolution hyperspectral and ultraspectral data will allow detangling of the highly heterogeneous usage megacity patterns by providing diagnostic identification of chemical composition from solids (refs) to gases (refs). To properly enable these next generation technologies for megacity include atmospheric radiative transfer modeling the complex and often aerosol laden, humid, urban microclimates, atmospheric transport and profile monitoring, spatial resolution, temporal cycles (diurnal and seasonal which involve interactions with the surrounding environment diurnal and seasonal cycles) and representative measurement approaches given traffic realities. Promising approaches incorporate contemporaneous airborne remote sensing and in situ measurements, nocturnal surface surveys, with ground station measurement

Leifer, Ira↗

Optical emission diagnostics of electron cyclotron resonance and glow discharge plasmas for a-Si:H and a-SiC:H film depositions

It is demonstrated that the steady-state and kinetic characteristics of ECR (electron cyclotron resonance) and RF glow discharge plasmas can be readily monitored by OES (optical emission spectroscopy) in real time during a-Si:H and a-SiC:H film depositions using an OMA detection system. The ECR and RF glow discharge plasmas used for a-Si:H and a-SiC:H film depositions were studied by monitoring the emission of SiH(asterisk), H(asterisk), H(asterisk)2, and CH(asterisk) excited states. The OES of the ECR plasma shows a strong emission at 434 nm from H(asterisk), which is not detectable in the glow discharge plasma. Steady-state OES studies have established preliminary correlations between SiH(asterisk) and CH(asterisk) emission intensities and the film deposition rate. Transient OES spectra of SiH4 and CH4 plasmas have shown different kinetics in SiH(asterisk) and CH(asterisk) emission intensities. Transient studies of the SiH(asterisk) emission intensity have indicated that additional mechanisms for producing the SiH(asterisk) species become evident in hydrogen-diluted silane plasmas.

Yang, C. L.↗

Advanced Diagnostic System on Earth Observing One

In this infusion experiment, the Livingstone 2 (L2) model-based diagnosis engine, developed by the Computational Sciences division at NASA Ames Research Center, has been uploaded to the Earth Observing One (EO-1) satellite. L2 is integrated with the Autonomous Sciencecraft Experiment (ASE) which provides an on-board planning capability and a software bridge to the spacecraft's 1773 data bus. Using a model of the spacecraft subsystems, L2 predicts nominal state transitions initiated by control commands, monitors the spacecraft sensors, and, in the case of failure, isolates the fault based on the discrepant observations. Fault detection and isolation is done by determining a set of component modes, including most likely failures, which satisfy the current observations. All mode transitions and diagnoses are telemetered to the ground for analysis. The initial L2 model is scoped to EO-1's imaging instruments and solid state recorder. Diagnostic scenarios for EO-1's nominal imaging timeline are demonstrated by injecting simulated faults on-board the spacecraft. The solid state recorder stores the science images and also hosts: the experiment software. The main objective of the experiment is to mature the L2 technology to Technology Readiness Level (TRL) 7. Experiment results are presented, as well as a discussion of the challenging technical issues encountered. Future extensions may explore coordination with the planner, and model-based ground operations.

Hayden, Sandra C.↗

Ares I-X Ground Diagnostic Prototype

Automating prelaunch diagnostics for launch vehicles offers three potential benefits. First, it potentially improves safety by detecting faults that might otherwise have been missed so that they can be corrected before launch. Second, it potentially reduces launch delays by more quickly diagnosing the cause of anomalies that occur during prelaunch processing. Reducing launch delays will be critical to the success of NASA's planned future missions that require in-orbit rendezvous. Third, it potentially reduces costs by reducing both launch delays and the number of people needed to monitor the prelaunch process. NASA is currently developing the Ares I launch vehicle to bring the Orion capsule and its crew of four astronauts to low-earth orbit on their way to the moon. Ares I-X will be the first unmanned test flight of Ares I. It is scheduled to launch on October 27, 2009. The Ares I-X Ground Diagnostic Prototype is a prototype ground diagnostic system that will provide anomaly detection, fault detection, fault isolation, and diagnostics for the Ares I-X first-stage thrust vector control (TVC) and for the associated ground hydraulics while it is in the Vehicle Assembly Building (VAB) at John F. Kennedy Space Center (KSC) and on the launch pad. It will serve as a prototype for a future operational ground diagnostic system for Ares I. The prototype combines three existing diagnostic tools. The first tool, TEAMS (Testability Engineering and Maintenance System), is a model-based tool that is commercially produced by Qualtech Systems, Inc. It uses a qualitative model of failure propagation to perform fault isolation and diagnostics. We adapted an existing TEAMS model of the TVC to use for diagnostics and developed a TEAMS model of the ground hydraulics. The second tool, Spacecraft Health Inference Engine (SHINE), is a rule-based expert system developed at the NASA Jet Propulsion Laboratory. We developed SHINE rules for fault detection and mode identification. The prototype uses the outputs of SHINE as inputs to TEAMS. The third tool, the Inductive Monitoring System (IMS), is an anomaly detection tool developed at NASA Ames Research Center and is currently used to monitor the International Space Station Control Moment Gyroscopes. IMS automatically "learns" a model of historical nominal data in the form of a set of clusters and signals an alarm when new data fails to match this model. IMS offers the potential to detect faults that have not been modeled. The three tools have been integrated and deployed to Hangar AE at KSC where they interface with live data from the Ares I-X vehicle and from the ground hydraulics. The outputs of the tools are displayed on a console in Hangar AE, one of the locations from which the Ares I-X launch will be monitored. The full paper will describe how the prototype performed before the launch. It will include an analysis of the prototype's accuracy, including false-positive rates, false-negative rates, and receiver operating characteristics (ROC) curves. It will also include a description of the prototype's computational requirements, including CPU usage, main memory usage, and disk usage. If the prototype detects any faults during the prelaunch period then the paper will include a description of those faults. Similarly, if the prototype has any false alarms then the paper will describe them and will attempt to explain their causes.

Schwabacher, Mark↗

Reusable Rocket Engine Turbopump Health Management System

A health monitoring expert system software architecture has been developed to support condition-based health monitoring of rocket engines. Its first application is in the diagnosis decisions relating to the health of the high pressure oxidizer turbopump (HPOTP) of Space Shuttle Main Engine (SSME). The post test diagnostic system runs off-line, using as input the data recorded from hundreds of sensors, each running typically at rates of 25, 50, or .1 Hz. The system is invoked after a test has been completed, and produces an analysis and an organized graphical presentation of the data with important effects highlighted. The overall expert system architecture has been developed and documented so that expert modules analyzing other line replaceable units may easily be added. The architecture emphasizes modularity, reusability, and open system interfaces so that it may be used to analyze other engines as well.

Surko, Pamela↗

Software Health Management: A Short Review of Challenges and Existing Techniques

Modern spacecraft (as well as most other complex mechanisms like aircraft, automobiles, and chemical plants) rely more and more on software, to a point where software failures have caused severe accidents and loss of missions. Software failures during a manned mission can cause loss of life, so there are severe requirements to make the software as safe and reliable as possible. Typically, verification and validation (V&V) has the task of making sure that all software errors are found before the software is deployed and that it always conforms to the requirements. Experience, however, shows that this gold standard of error-free software cannot be reached in practice. Even if the software alone is free of glitches, its interoperation with the hardware (e.g., with sensors or actuators) can cause problems. Unexpected operational conditions or changes in the environment may ultimately cause a software system to fail. Is there a way to surmount this problem? In most modern aircraft and many automobiles, hardware such as central electrical, mechanical, and hydraulic components are monitored by IVHM (Integrated Vehicle Health Management) systems. These systems can recognize, isolate, and identify faults and failures, both those that already occurred as well as imminent ones. With the help of diagnostics and prognostics, appropriate mitigation strategies can be selected (replacement or repair, switch to redundant systems, etc.). In this short paper, we discuss some challenges and promising techniques for software health management (SWHM). In particular, we identify unique challenges for preventing software failure in systems which involve both software and hardware components. We then present our classifications of techniques related to SWHM. These classifications are performed based on dimensions of interest to both developers and users of the techniques, and hopefully provide a map for dealing with software faults and failures.

Pipatsrisawat, Knot↗