Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

High-precision determination of iron oxidation state in silicate glasses using XANES

Fe K-edge X-ray absorption near-edge structure (XANES) and Moessbauer spectra were collected on natural basaltic glasses equilibrated over a range of oxygen fugacity (QFM - 3.5 to QFM + 4.5). The basalt compositions and fO{sub 2} conditions were chosen to bracket the natural range of redox conditions expected for basalts from mid-ocean ridge, ocean island, back-arc basin, and arc settings, in order to develop a high-precision calibration for the determination of Fe{sup 3+}/{Sigma}Fe in natural basalts. The pre-edge centroid energy, corresponding to the 1s {yields} 3d transition, was determined to be the most robust proxy for Fe oxidation state, affording significant advantages compared to the use of other spectral features. A second-order polynomial models the correlation between the centroid and Fe{sup 3+}/{Sigma}Fe, yielding a precision of {+-} 0.0045 in Fe{sup 3+}/{Sigma}Fe for glasses with Fe{sup 3+}/{Sigma}Fe > 8%, which is comparable to the precision of wet chemistry. This high precision relies on a Si (311) monochromator to better define the Fe{sup 2+} and Fe{sup 3+} transitions, accurate and robust modeling of the pre-edge feature, dense fO{sub 2}-coverage and compositional appropriateness of reference glasses, and application of a non-linear drift correction. Through re-analysis of the reference glasses across three synchrotron beam sessions, we show that the quoted precision can be achieved (i.e., analyses are reproducible) across multiple synchrotron beam sessions, even when spectral collection conditions (detector parameters or sample geometry) change. Rhyolitic glasses were also analyzed and yield a higher centroid energy at a given Fe{sup 3+}/{Sigma}Fe than basalts, implying that major variations in melt structure affect the relationship between centroid position and Fe{sup 3+}/{Sigma}Fe, and that separate calibrations are needed for the determination of oxidation state in basalts and rhyolites.

43 PARTICLE ACCELERATORS↗

Magnetic design of the commutational magnet and quadrupoles for PERLE accelerator

ER@CEBAF is an effort to demonstrate multi-GeV multipass energy recovery with a low beam current in CEBAF. The CEBAF race-track-shaped geometry allows its linacs to accommodate multiple energy beams simultaneously. However, five energy recovery passes complicate the beamline optics design process. Individual recirculating arcs each transport one beam energy, and are shared between accelerating/decelerating beams. This paper presents a CEBAF optics redesign to accommodate the ER@CEBAF multi-pass ER scheme. Isochronous arcs were retuned to match into optics solutions for optimized 10-pass linacs. In this paper, we discuss the optics re-design process for ER@CEBAF based on the existing CEBAF layout.

Neththikumara, I.↗

Multiple-mode large deflection random response of beams with nonlinear damping subjected to acoustic excitation

Multiple-mode nonlinear analysis is carried out for beams subjected to acoustic excitation. Effects of both nonlinear damping and large-deflection are included in the analysis in an attempt to explain the experimental phenomena of aircraft panels excited at high sound pressure levels; that is the broadening of the strain response peaks and the increase of modal frequency. An amplitude dependent nonlinear damping model is used in the anlaysis to study the effects and interactions of multiple modes, nonlinear stiffness and nonlinear damping on the random response of beams. Mean square maximum deflection, mean square maximum strain, and spectral density function of maximum strain for simple supported and clamped beams are obtained. It is shown analytically that nonlinear damping contributes significantly to the broadening of the response peak and to the mean square deflection and strain.

Prasad, C. B.↗

Synthesizing radioisotopes using an energy recovery linac

An apparatus and method for the production of radioisotopes utilizing an energy recovery linac. The ERL system is composed of an electron beam source, multiple superconducting radio frequency cavities operating at 4.5 K, a thin radiator, a target material, and a beam dump. The accompanying method discloses the use of the ERL system to generate desired radioisotopes via target interaction with bremsstrahlung photons while allowing recovery of a substantial portion of the electron beam energy before the beam is extracted to the beam dump.

Areti, Hari↗

Method of Making Large Area Nanostructures

A method which enables the high speed formation of nanostructures on large area surfaces is described. The method uses a super sub-micron beam writer (Supersebter). The Supersebter uses a large area multi-electrode (Spindt type emitter source) to produce multiple electron beams simultaneously scanned to form a pattern on a surface in an electron beam writer. A 100,000 x 100,000 array of electron point sources, demagnified in a long electron beam writer to simultaneously produce 10 billion nano-patterns on a 1 meter squared surface by multi-electron beam impact on a 1 cm squared surface of an insulating material is proposed.

Marks, Alvin M.↗

Tunable Laser-Plasma Amplifier (Final Report)

Exploration at the laser intensity frontier has always offered new avenues for physics and reaching beyond this frontier is a grand challenge. Present-day petawatt-class lasers provide focused intensities on target of 10 22 W/cm 2 , corresponding to electric fields of 200 TV/m, while laser-plasma amplification opens a route for focused intensities well above 10 23 W/cm 2 . Intensities in this range provide the ability to test quantum electrodynamics in the unexplored low-energy, strong-field regime where signatures for new physics may arise. The behavior of matter under such extraordinary conditions is a rich and fascinating subject, not only in its own right in fundamental plasma physics, but for the many potential applications that promise to enrich the natural sciences in the future, including compact electron-beam, ion-beam particle accelerators, and ultra-bright X-ray sources. Although laser systems are now under construction internationally to access intensities of 10 23 W/cm 2 , the current technologies used appear to be fundamentally limited to these intensities. The realization of intensities beyond 10 23 W/cm 2 using parametric amplification in plasmas promises a breakthrough in high-energy density physics. Parametric amplification using Raman scattering in a plasma could provide the enabling technology for the generation of ultra-high-power laser pulses, but a more complete understanding of the nonlinear optics of plasmas is required. There is a significant gap in well-diagnosed laser-plasma instability studies of nonlinear plasma-wave phenomena, which are critical to understand for future laser-plasma devices. To achieve an efficient laser-plasma amplifier, plasma waves must be driven to large amplitude where significant energy can be rapidly transferred from the pump to the seed over the pulse duration of the seed. Simulations suggest that this nonlinear pump depletion regime can be achieved in the “pi-pulse” amplification regime. While simulations show this optimal regime with efficient amplification, it has remained elusive in experiments and there is a growing consensus within the community that thermal effects and pump beam limitations prevent laser-plasma amplifiers from progressing through the linear regime into the nonlinear pump depletion regime. Previous experiments have been significantly limited by the laser power available at the necessary wavelengths for the seed laser; therefore, the amplification is required to start in the linear regime where it is sensitive to many deleterious effects. The enabling technology (currently unique to plasma-wave amplification in the world) at the University of Rochester is the ability to provide a seed pulse with sufficient power (4 mJ/100 fs seed) to immediately drive nonlinear plasma waves into the pi-pulse regime and to tune its wavelength to optimize the efficiency of energy transfer. This in combination with the state-of-the-art OMEGA heater beams providing multiple kilojoules in a nanosecond to sufficiently heat the plasma make this system distinct from previous studies. These heater beams will provide, for the first time in Raman amplification studies, a homogeneous electron temperature high enough to prevent pump beam propagation issues that have plagued previous experiments. These systems will provide a platform for driving electron-plasma waves into the nonlinear regime where pump depletion and pulse shortening are predicted to lead to high amplification efficiencies (>30%). The Team has made significant progress through prior support from DOE Fusion Energy Sciences [DOE Office of Science Award Number DE-SC0016253 (2016-2022)]. This includes twenty-two peer-reviewed manuscripts, one patent, ten contributed talks presented at international conferences, and research that was highlighted as invited talks at fifteen international conferences. The broader impacts of this research are evident in the support of early career scientists, two Ph.D. theses, four current graduate students, a Masters Project, two undergraduate researchers, and an underrepresented minority student hired through the California Alliance for Minority Participation who now works as a Research Engineer in the group. This research met all of the funded research objectives and the highlights from primary Raman amplification thrust of this work are discussed below and form the foundation for the proposed research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-G-TeP4-12: Individual Beam QA for a Robotic Radiosurgery System Using a Scintillator Cone

Purpose: The targeting accuracy of the Cyberknife system is measured by end-to-end tests delivering multiple isocentric beams to a point in space. While the targeting accuracy of two representative beams can be determined by a Winston-Lutz-type test, no test is available today to determine the targeting accuracy of each clinical beam. We used a scintillator cone to measure the accuracy of each individual beam. Methods: The XRV-124 from Logos Systems Int’l is a scintillator cone with an imaging system that is able to measure individual beam vectors and a resulting error between planned and measured beam coordinates. We measured the targeting accuracy of isocentric and non-isocentric beams for a number of test cases using the Iris and the fixed collimator. The average difference between plan and measured beam position was 0.8–1.2mm across the collimator sizes and plans considered here. The max error for a single beam was 2.5mm for the isocentric plans, and 1.67mm for the non-isocentric plans. The standard deviation of the differences was 0.5mm or less. Conclusion: The CyberKnife System is specified to have an overall targeting accuracy for static targets of less than 0.95mm. In E2E tests using the XRV124 system we measure average beam accuracy between 0.8 to 1.23mm, with maximum of 2.5mm. We plan to investigate correlations between beam position error and robot position, and to quantify the effect of beam position errors on patient specific plans. Martina Descovich has received research support and speaker honoraria from Accuray.

60 APPLIED LIFE SCIENCES↗

Powering CEBAF's Extraction Cavities At 12 GeV

CEBAF (Continuous Electron Beam Accelerator Facility) at Jefferson Lab was initially designed to deliver up to a 4 GeV electron beam simultaneously to three experimental halls. The maximum deliverable energy was raised to 6 GeV and CEBAF ran there until May of 2012 after which CEBAF entered an upgrade shutdown. After the upgrade, scientists plan to use CEBAF to deliver 11 GeV beam to the three original experimental halls and 12 GeV to new hall ? Hall D. Delivering beams to multiple halls at the new energy requires increased RF power to drive the separation cavities and adding a 750 MHz beam repetition rate to deliver beam to all halls simultaneously. Doubling the beam energy means doubling field strength in the cavities by quadrupling delivered power. 750 MHz beam repetition rate requires new 750 MHz capable cavities and a frequency change to one of the existing IOT amplifiers powering these cavities, and new 499 MHz Solid State Amplifiers to power four downstream cavities. Topics covered will include: verifying the Cavity?s power capabilities, modifications to the 750 MHz system and new cavities, and the decision process in selecting an amplifier type to power four downstream cavities.

Wissmann, Mark↗

Design study of low-energy beam transport for multi-charge beams at RAON

The Rare isotope Accelerator Of Newness (RAON) at the Rare Isotope Science Project (RISP) is being designed to simultaneously accelerate beams with multiple charge states. It includes a driver superconducting (SC) linac for producing 200 MeV/u and 400 kW continuous wave (CW) heavy ion beams from protons to uranium. The RAON consists of a few electron cyclotron resonance ion sources, a low-energy beam transport (LEBT) system, a CW 81.25 MHz, 500 keV/u radio frequency quadrupole (RFQ) accelerator, a medium-energy beam transport system, the SC linac, and a charge-stripper system. The LEBT system for the RISP accelerator facility consists of a high-voltage platform, two 90° dipoles, a multi-harmonic buncher (MHB), solenoids, electrostatic quadrupoles, a velocity equalizer, and a diagnostic system. The ECR ion sources are located on a high-voltage platform to reach an initial beam energy of 10 keV/u. After extraction, the ion beam is transported through the LEBT system to the RFQ accelerator. The generated charge states are selected by an achromatic bending system and then bunched by the MHB in the LEBT system. The MHB is used to achieve a small longitudinal emittance in the RFQ by generating a sawtooth wave with three harmonics. Here, we present the results and issues of the beam dynamics of the LEBT system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SETI OBSERVATIONS OF EXOPLANETS WITH THE ALLEN TELESCOPE ARRAY

We report radio SETI observations on a large number of known exoplanets and other nearby star systems using the Allen Telescope Array (ATA). Observations were made over about 19000 hr from 2009 May to 2015 December. This search focused on narrowband radio signals from a set totaling 9293 stars, including 2015 exoplanet stars and Kepler objects of interest and an additional 65 whose planets may be close to their habitable zones. The ATA observations were made using multiple synthesized beams and an anticoincidence filter to help identify terrestrial radio interference. Stars were observed over frequencies from 1 to 9 GHz in multiple bands that avoid strong terrestrial communication frequencies. Data were processed in near-real time for narrowband (0.7–100 Hz) continuous and pulsed signals with transmitter/receiver relative accelerations from −0.3 to 0.3 m s{sup −2}. A total of 1.9 × 10{sup 8} unique signals requiring immediate follow-up were detected in observations covering more than 8 × 10{sup 6} star-MHz. We detected no persistent signals from extraterrestrial technology exceeding our frequency-dependent sensitivity threshold of 180–310 × 10{sup −26} W m{sup −2}.

79 ASTRONOMY AND ASTROPHYSICS↗

Rapid thermal emittance and quantum efficiency mapping of a cesium telluride cathode in an rf photoinjector using multiple laser beamlets

Thermal emittance and quantum efficiency (QE) are key figures of merit of photocathodes, and their uniformity is critical to high-performance photoinjectors. Several QE mapping technologies have been successfully developed; however, there is still a dearth of information on thermal emittance maps. This is because of the extremely time-consuming procedure to gather measurements by scanning a small beam across the cathode with fine steps. To simplify the mapping procedure and to reduce the time required to take measurements, we propose a new method that requires only a single scan of the solenoid current to simultaneously obtain thermal emittance and QE distribution by using a pattern beam with multiple beamlets. In this paper, its feasibility has been confirmed by both beam dynamics simulation and theoretical analysis. The method has been successfully demonstrated in a proof-of-principle experiment using an L-band radio-frequency photoinjector with a cesium telluride cathode. In the experiment, seven beamlets were generated from a microlens array system and their corresponding thermal emittance and QE varied from 0.93 to 1.14 mu m/nun and from 4.6% to 8.7%, respectively. We also discuss the limitations and future improvements of the method in this paper.

43 PARTICLE ACCELERATORS↗

Method and apparatus for removing unwanted reflections from an interferometer

A device for eliminating unwanted reflections from refractive optical elements in an optical system is provided. The device operates to prevent desired multiple fringe patterns from being obscured by reflections from refractive elements positioned in proximity to a focal plane of the system. The problem occurs when an optical beam is projected into, and reflected back out of, the optical system. Surfaces of the refractive elements reflect portions of the beam which interfere with portions of the beam which are transmitted through the refractive elements. Interference between the reflected and transmitted portions of the beam produce multiple fringe sets which tend to obscure desired interference fringes. With the refractive optical element in close proximity to the focal plane of the system, the undesired reflected light reflects at an angle 180 degrees opposite from the desired transmitted beam. The device exploits the 180-degree offset, or rotational shear, of the undesired reflected light by providing an optical stop for blocking one-half of the cross-section of the test beam. By blocking one-half of the test beam, the undesired offset beam is blocked, while the returning transmitted beam passes into the optical system unaffected. An image is thereby produced from only the desired transmitted beam. In one configuration, the blocking device includes a semicircular aperture which is caused to rotate about the axis of the test beam. By rotating, all portions of the test beam are cyclically projected into the optical system to thereby produce a complete test image. The rotating optical stop is preferably caused to rotate rapidly to eliminate flicker in the resulting image.

Steimle, Lawrence J.↗

A Pion Production and Capture System for a 4 MW Target Station

A study of a pion production and capture system for a 4 MW target station for a neutrino factory or muon collider is presented. Using the MARS code, we simulate the pion production produced by the interaction of a free liquid mercury jet with an intense proton beam. We study the variation of meson production with the direction of the proton beam relative to the target. We also examine the influence on the meson production by the focusing of the proton beam. The energy deposition in the capture system is determined and the shielding required in order to avoid radiation damage is discussed. The exploration for the multiple proton beam entry directions relative to mercury jet in the 8GeV proton beam case demonstrates that an asymmetric layout is required in order to achieve the same beam/jet crossing angle at the jet axis. We find a correlation between the distance of beam relative to the jet and the meson production. The peak meson production is 8% higher than for the lowest case. The examination of the influence on the meson production by the focusing of the proton beam shows the meson production loss is negligible (<1%) for a beta function to be 0.3m or higher for the proton beam. By investigating the energy deposition in the target/capture system, we see that the bulk of 4-MW proton beam power is deposited in the water cooled tungsten-carbide (WC) shielding, the mercury jet and the capture beam pipe. In addition, high power deposition in the first superconducting coil causes an issue for its operation and life time. Enhanced shielding is necessary to lower the radiation damage.

43 PARTICLE ACCELERATORS↗

Interpretable and Efficient Interferometric Contrast in Scanning Transmission Electron Microscopy with a Diffraction-Grating Beam Splitter

Efficient imaging of biomolecules, 2D materials and electromagnetic fields depends on retrieval of the phase of transmitted electrons. We demonstrate a method to measure phase in a scanning transmission electron microscope using a nanofabricated diffraction grating to produce multiple probe beams. The measured phase is more interpretable than phase-contrast scanning transmission electron microscopy techniques without an off-axis reference wave, and the resolution could surpass that of off-axis electron holography. Here, we apply the technique to image nanoparticles, carbon sub- strates and electric fields. The contrast observed in experiments agrees well with contrast predicted in simulations.

36 MATERIALS SCIENCE↗