Search NASA⌕ Search

SEARCH · Search NASA

Results for “object oriented methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

In-Silico Design of Next Generation Cellulose-Derived Packaging Materials (CRADA Final Report)

Developing sustainable solutions for single-use packaging is an important objective to combat the environmental crisis of plastics pollution. Most embodiments of cellulose-based packaging materials, including CellophaneTM, are completely biodegradable in both terrestrial and marine environments. However, petroleum-derived alternatives offer some performance advantages for metrics such as moisture barriers and mechanical properties. This project leverages molecular dynamics simulation to investigate how molecular modifications to cellulose-based polymer assemblies impact their material properties. An important performance criterion for the modified materials was to retain biodegradability; thus, modifications by naturally occurring, biodegradable additives were the focus of this study. Specifically, we developed models with xylan and lignin of varying monomeric compositions into the cellulose matrix. The mechanical properties were investigated by performing stress-strain simulations, and the water barrier and hydrophobicity were investigated by simulating the water contact angle. Our findings indicate that the incorporation of xylan into the cellulose matrix tends to increase the mechanical properties with an optimal loading of ~27 wt%. We also predict that orienting the nanoscale directionality of the xylan chains such that they are perpendicular to the cellulose fibrils will dramatically increase mechanical strength. In contrast, the incorporation of lignin tends to weaken the composite at all loadings investigated. Simulations of water contact angle predicted that coating polymers on the surface of the cellulose assembly creates a more hydrophobic surface than incorporating them throughout the matrix. Of the coatings investigated, lignin resulted in the most hydrophobic surface, followed by pectin and keratin, which both imparted modest increases in hydrophobicity. Future experimental work done by Futamura will focus on designing material prototypes to capitalize on the predictions of performance enhancement obtained from molecular modeling. While substantial progress was made by the simulations performed in this project, there still exists a vast parameter space that we were unable to investigate, including branching, functional group decoration, and degree of polymerization of polymer additives. However, the methods developed in this initial investigation will facilitate more rapid evaluation of the impact of molecular characteristics on the performance of biopolymer composite materials and thereby accelerate future materials discovery efforts in this area.

36 MATERIALS SCIENCE↗

The protoplanetary disc around HD 169142: circumstellar or circumbinary?

ABSTRACT Stellar binaries represent a substantial fraction of stellar systems, especially among young stellar objects. Accordingly, binaries play an important role in setting the architecture of a large number of protoplanetary discs. Binaries in coplanar and polar orientations with respect to the circumbinary disc are stable configurations and could induce non-axisymmetric structures in the dust and gas distributions. In this work, we suggest that the structures shown in the central region of the protoplanetary disc HD 169142 are produced by the presence of an inner stellar binary and a circumbinary (P-type) planet. We find that a companion with a mass ratio of 0.1, semimajor axis of 9.9 au, eccentricity of 0.2, and inclination of 90°, together with a 2 MJ coplanar planet on a circular orbit at 45 au reproduce the structures at the innermost ring observed at 1.3 mm and the shape of spiral features in scattered light observations. The model predicts changes in the disc’s dust structure, and star’s astrometric parameters, which would allow testing its veracity by monitoring this system over the next 20 yr.

79 ASTRONOMY AND ASTROPHYSICS↗

NDE and DE of PWSCC Found in the J-Groove Weld of a Removed-From-Service Control Rod Drive Mechanism

Studies conducted at the Pacific Northwest National Laboratory (PNNL) in Richland, Washington focused on assessing the effectiveness of nondestructive examination (NDE) techniques for inspecting control rod drive mechanism (CRDM) nozzles and J-groove weldments. The primary objective of this work is to provide information to the United States Nuclear Regulatory Commission (US NRC) on the effectiveness of NDE methods as related to the in-service inspection of CRDM nozzles and J-groove weldments, and to enhance the knowledge base of primary water stress corrosion cracking (PWSCC) through destructive characterization of the CRDM assemblies. Two CRDM assemblies were removed from service, decontaminated, and then used in a series of laboratory NDE and DE measurements; this report addresses the following questions: 1) What did each NDE technique detect?, 2) What did each NDE technique miss?, 3) How accurately did each NDE technique characterize the detected flaws?, and finally 4) What were the basis for the NDE techniques performance? Two CRDM assemblies including the CRDM nozzle, the J-groove weld, buttering, and a portion of the ferritic head material were selected for this study. This paper focuses on a CRDM assembly that contained suspected PWSCC, based on in-service inspection data and through-wall leakage. The laboratory NDE measurements used to examine the CRDM assembly followed standard industry techniques for conducting in-service inspections of CRDM nozzles and the crown of the J-groove welds and buttering. These techniques included eddy current testing, time of flight diffraction ultrasound, and penetrant testing. In addition, other laboratory-based NDE methods were employed to conduct inspections of the CRDM assembly with particular emphasis on inspecting the J-groove weld and buttering. These techniques included volumetric ultrasonic inspection of the J-groove weld metal, visual testing via replicant material of the J-groove weld and high resolution photography of the J-groove weld crown and buttering. The results from these NDE studies were used to guide the development of the destructive characterization plan. The NDE studies found several crack-like indications. The NDE and DE studies determined that one of these was a through-weld radially-oriented PWSCC crack in the wetted surface of the J-groove weld, located at the transition point between the weld and the buttering. The crack was 6 mm long on the surface and quickly grew to 25 mm long at a depth of 8 mm, covering the length of the weld between the penetration tube and the carbon steel. The NDE studies found that only ET was able to detect the through-weld crack. The crack was oriented poorly for the ultrasonic testing, and was too tight for accurate PT or VT. The ET voltage response of the flaw was 30% that of a deep EDM notch. The DE performed on the crack consisted of slicing the crack into thin sections, polishing the sections, and then using optical and scanning electron microscopy (SEM) to characterize the crack. DE shows the crack was PWSCC and that it initiated on the wetted surface, grew and expanded through the weld metal, and exited into the annulus. The SEM examinations showed the crack followed the weld grain boundaries as it progressed through the weld. The crack was branched and discontinuous along its length.

36 MATERIALS SCIENCE↗

Probing circular polarization and magnetic field structure in active galactic nuclei

The composition and magnetic field morphology of relativistic jets can be studied using circular polarization (CP) measurement. Recent three-dimensional relativistic magnetohydrodynamic (3D RMHD) simulations coupled with radiative transfer (RT) calculations make strong predictions about the level (and morphology) of the jet’s CP emission. These simulations show that the sign of CP and the electric vector position angle (EVPA) are both sensitive to the jet’s magnetic field morphology within the radio core. We probe this theory by exploring whether the jet’s radio core EVPA orientation is consistent with the observed sign of the core CP in deep full-track polarimetric observations. Based on a selection of sources from earlier MOJAVE observations, we aim to probe the nature of linear polarization (LP) and CP in the innermost regions of jets from a small sample of nine blazars. This sample includes sources that have exhibited: (i) positive CP; (ii) negative CP; or (iii) positive and negative CP simultaneously in the radio core region. By coupling deep polarimetric observations of a carefully selected sample of blazars with state-of-the-art RMHD and RT calculations, we hope to gain a deeper understanding of the physics of blazar jets.

79 ASTRONOMY AND ASTROPHYSICS↗

Dendrite-resolved, full-melt-pool phase-field simulations to reveal non-steady-state effects and to test an approximate model

In this report we study the epitaxial, columnar growth of (multiply oriented) dendrites/cells for a spot melt in a polycrystalline Al–Cu substrate using two-dimensional, phase-field, direct numerical simulations (DNS) at the full-melt-pool scale. Our main objective is to compare the expensive DNS model to a much cheaper but approximate “line” model in which a single-crystal phase-field simulation is confined to a narrow rectangular geometry. To perform this comparison, we develop algorithms that automatically extract quantities of interest (QoIs) from both DNS and line models. These QoIs allow us to quantitatively assess the assumptions in the line model and help us analyze its discrepancy with the DNS model. We consider four sets of heat source parameters, mimicking welding and additive manufacturing conditions, that create a combination shallow and deep melt pools. Our largest DNS simulation used 16K x 14K grid points in space. Our main findings can be summarized as follows. Under AM conditions, the QoIs of line models are in excellent agreement with the full DNS results for both shallow and deep melt pools. Under welding conditions, the primary spacing of the DNS model is smaller than the prediction of line model. We identify a geometric crowding effect that accounts for the discrepancies between the DNS and line models. We propose two potential mechanisms that determine the response of the microstructure to geometric crowding.

36 MATERIALS SCIENCE↗

Accelerated Aging Humidity Chamber for Nuclear Grade HEPA Filter Media

A unique accelerated aging humidity chamber for simulating the natural aging process of nuclear grade high efficiency particulate air (HEPA) filter media is being designed, implemented, and tested. The nuclear industry currently lacks information regarding the shelf life and service life of HEPA filter media. The Department of Energy recommends disposing of HEPA filters 10 years after the manufacture date for filters operated under dry conditions. Studies have shown the tensile strength and water repellency of HEPA filter media diminish with age. The chamber's principal function is to sustain an elevated relative humidity condition for an extended duration specified by the Arrhenius aging model. To accomplish this, various design parameters were established: (1) consistently achieve uniform humidity conditions within the chamber to equally expose media sheets, (2) ensure the chamber is sufficiently sealed to mitigate the uncontrolled infiltration of air, (3) confidently secure the media sheets to avert the introduction of unnecessary stressing/creasing, (4) fabricate the chamber from clear polycarbonate material to allow inspection of the media sheets, (5) provide a safe and ergonomic design for personnel, (6) ensure the chamber design is replicable and relatively easy to fabricate/assemble. A humidity source, fan, PID controller, humidity and temperature transmitters, and data loggers are required for proper operation and control of the chamber. The humidity source must accommodate target values up to 95% relative humidity throughout the chamber. The three humidity and temperature transmitters are strategically spaced throughout the chamber to ensure uniform conditions. The 10 cubic feet per minute (CFM) fan selected intends to accomplish the desired air change rate inside the chamber of approximately 20 air changes per hour (ACH). The 2 plenums on the upper and lower portions of the chamber utilize a perforated design to uniformly distribute air, promote air mixing, and control the air velocity entering the chamber. Industrial blueprint hanging clamps are being retrofitted to be seated within the chamber drawers and firmly secure the nuclear grade filter media. The aged media will be evaluated using autopsy methodology, and the results obtained intend to help clarify the useful life of nuclear grade HEPA filters. Nuclear grade high efficiency particulate air (HEPA) filters are defined as disposable, extended-media, dry-type filters with a rigid casing enclosing the full depth of the pleats and have a minimum particle removal efficiency of 99.97%. [1] - HEPA filters are constantly exposed to stressors and subsequently have been shown to degrade as the filter ages. Properties such as tensile strength and water repellency, along with others, are negatively impacted. [2] - Due to the scarcity of naturally aged HEPA filters available, it is crucial to develop accelerated aging methods which effectively mimic the natural degradation effects. - After accelerated aging, the filters are subject to testing in the Axial Flow Large Scale Test Stand (ALSTS) and other analysis techniques such as the same qualification tests performed directly after being manufactured. - Quality data is necessary for future decisions regarding the lifetime of nuclear grade HEPA filters. - The objective is to develop a prototype accelerated aging humidity chamber for nuclear grade HEPA filter media. The chamber should expose the media to commonly occurring stressors to expedite the degradation process caused by aging. PID yields reliable and reproducible results: - CFD model correlates well with actual performance; - Further analysis is needed to complete characterization; - Future work for the chamber is still to be completed. The data shown in Figure 5 and Table 1 indicate the system is functioning as designed. As can be determined from the system response evaluation in Table 1, the PID controller is yielding reliable and reproducible results at each set point. As the set point increases, the time constant and 20% settling time increase accordingly. From the results in Table 1, it stands to reason that the CFD model correlates well with the actual performance of the system. Each system response parameter for the 90%RH* CFD model is slightly lower than the parameters collected from the physical model tested at an equivalent set point. This is to be expected considering the inlet in the CFD model is a constant supply of water vapor, whereas the physical model uses a PID controller to monitor the amount of water vapor needed and reacts accordingly. More analysis is still to be done on the prototype chamber. A pressure test will be conducted in order to determine the hourly leak rate of the chamber. This test will involve constant air flow into the chamber until the desired pressure is reached. A uniformity test will also be conducted in order to ensure each filter medium is being exposed to equivalent relative humidity levels. This test will involve an array of humidity meters strategically oriented inside the chamber to record any possible gradients. Future work for the chamber includes dehumidification abilities, tests while fully loaded with filters, and temperature control. Once completed, the autopsy team at Institute of Clean Energy Technology will conduct necessary accelerated aging studies as needed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Intermediate-Scale Hydraulic Fracturing in a Deep Mine - kISMET Project Summary 2016

In support of the U.S. DOE SubTER Crosscut initiative, we established a field test facility in a deep mine and designed and carried out in situ hydraulic fracturing experiments in the crystalline rock at the site to characterize the stress field, understand the effects of rock fabric on fracturing, and gain experience in monitoring using geophysical methods. The project also included pre- and post-fracturing simulation and analysis, laboratory measurements and experiments, and we conducted an extended analysis of the local stress state using previously collected data. Some of these activities are still ongoing. The kISMET (permeability (k) and Induced Seismicity Management for Energy Technologies) experiments meet objectives in SubTER’s “stress” pillar and the “new subsurface signals” pillar. The kISMET site was established in the West Access Drift of SURF 4850 ft (1478 m) below ground (on the 4850L) in phyllite of the Precambrian Poorman Formation. We drilled and cored five near-vertical boreholes in a line on 3 m spacing, deviating the two outermost boreholes slightly to create a five-spot pattern around the test borehole centered in the test volume at ~1528 m (5013 ft). Laboratory measurements of core from the center test borehole showed P-wave velocity heterogeneity along each core indicating strong, fine-scale (~1 cm or smaller) changes in the mechanical properties of the rock. The load-displacement record on the core suggests that the elastic stiffness is anisotropic. Tensile strength ranges between 3-7.5 MPa and 5-12 MPa. Permeability measurements are planned, as are two types of laboratory miniature hydraulic fracturing experiments to investigate the importance of rock fabric (anisotropy and heterogeneity) on near-borehole hydraulic fracture generation. Pre-fracturing numerical simulations with INL’s FALCON discrete element code predicted a fracture radius of 1.2 m for a corresponding injection volume of 1.2 L for the planned fractures, and negligible microseismicity. Field measurements of the stress field by hydraulic fracturing showed that the minimum horizontal stress at the kISMET site averages 21.7 MPa (3146 psi) pointing approximately N-S (356 degrees azimuth) and plunging slightly NNW at 12°. The vertical and horizontal maximum stress are similar in magnitude at 42-44 MPa (6090-6380 psi) for the depths of testing which averaged approximately 1530 m (5030 ft). Hydraulic fractures were remarkably uniform suggesting core-scale and larger rock fabric did not play a role in controlling fracture orientation. Monitoring using ERT and CASSM in the four monitoring boreholes, and passive seismic accelerometer-based measurements in the West Access Drift, was carried out during the generation of a larger fracture (so-called stimulation test) at a depth of 40 m below the invert. ERT was not able to detect the fracture created, nor were the accelerometers in the drift, but microseismicity was detected for first (deepest) hydraulic-fracturing stress measurement. The CASSM data have not yet been analyzed. Analytical solutions suggest fracture radius of the large fracture (stimulation test) was more than 6 m, depending on the unknown amount of leak-off. The kISMET results for stress state are consistent with large-scale mid-continent estimates of stress. Currently we are using the orientation of the stress field we determined to interpret a large number of borehole breakouts recorded in nearby boreholes at SURF to generate a more complete picture of the stress field and its variations at SURF. The efforts on the project have prompted a host of additional follow-on studies that we recommend be carried out at the kISMET site.

02 PETROLEUM↗

Fracture Toughness Evaluation for Spent Nuclear Fuel Clad Systems Using Spiral Notch Torsion Fracture Toughness Test

Many radioactive materials within the nuclear fuel cycle present a significant hazard. Such materials include spent nuclear fuel, high-level waste, legacy waste and other nuclear materials. These materials are often held in long-term storage as an interim stage within their lifecycle, including reuse or disposal. Safety and security of spent nuclear fuel (SNF) interim storage installations and follow-on SNF transportations to its final repository sites are very important, due to a great concentration of fission products, actinides and activation products. Fracture mechanics approach in applying to SNF system reliability investigation, especially for the high burn up (HBU) SNF, during SNF long term dry storage or SNF transportation is necessary due to the inherited flaws and inhomogeneity structures existed in a SNF system from the reactor operation. For instance, such as hydride and oxide formation, surface flaw induced by SNF assembly contact interactions, or internal flaws induced by pellet-clad mechanical interaction (PCMI). However, none of the existing fracture toughness data deal with fuel cladding specific geometry or SNF material conditions, such as cladding structure with the segment fuel pellets configuration and the PCMI mechanism. Consequently, the application of existing fracture toughness data to SNF system reliability investigation can be error prone; thus, the development of an industry-wide consensus fracture mechanics approach is needed. The objective of this research is to develop an in-situ fracture mechanics testing protocol, including the associated analytical procedure, that is suitable for evaluating the SNF fracture toughness. Fracture toughness data was obtained under quasi-static fracture loading using Oak Ridge National Laboratory (ORNL) developed Spiral Notch Torsion Test (SNTT) technology carried out on a biaxial tension/torsion tester. These data will be used to support SNF reliability investigation during long-tern SNF dry storage stage or in the follow-on SNF system transport to the final repository sites. SNTT has been a recent breakthrough in measuring fracture toughness for different materials, including metals, ceramics, concrete and polymers composites. Due to its high geometry constraint and unique loading condition, SNTT can be used to measure the fracture toughness with smaller specimens without concern of size effects. The application of SNTT to brittle materials has been proved to be successful. The micro-cracks induced by original notches in brittle materials could ensure crack growth in SNTT samples. Therefore, no fatigue pre cracks are needed for brittle materials specimens. The application of SNTT to the ductile material to generate valid toughness data will require a test sample with sufficient pre-crack length to increase the sample localized constraint at crack front. Fatigue pre-crack growth techniques with the associated compliance function estimated was developed for estimating the crack penetration depth to monitor the fatigue crack growth evolution. In order to extend SNTT approach to a thin shell cladding structure material, a new testing protocol and the associated analytical procedure for estimating the SNF fracture toughness was developed. The detailed SNTT approach and its estimated fracture toughness for the Zr-4 cladding structure with segment alumina inserts are presented in this report. The SNTT test results indicate that SNTT method is a reliable test approach with good repeatability in applying to Zr-4 cladding material. For the medium and the short crack length, the estimate J Q upon fracture for the baseline Zr-4 cladding is at 285.7 lb/in with 2-sigma uncertainty of 18.59 lb/in., and the associated K Q is at 61.4 Ksi√in. For a long crack length, the crack initialization orientation is apparently deviated from the principle tensile stress contour – 45° spiral crack front (i.e., Mode I + Mode III failure mechanism); and the estimated J Q is at 108 lb/in., the associated K Q is at 37.7 Ksi√in. The estimate Mode I J Q (along the 45° pitch principle tensile stress contour) is at 200 lb/in.; which indicate a significant reduction in the fracture toughness in a tubing structure under mixed mode loading condition, Mode I + Mode III, compared to that of Mode I (tensile stress dominated) alone.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Endocervical ultrasound applicator for integrated hyperthermia and HDR brachytherapy in the treatment of locally advanced cervical carcinoma

Purpose: The clinical success of hyperthermia adjunct to radiotherapy depends on adequate temperature elevation in the tumor with minimal temperature rise in organs at risk. Existing technologies for thermal treatment of the cervix have limited spatial control or rapid energy falloff. The objective of this work is to develop an endocervical applicator using a linear array of multisectored tubular ultrasound transducers to provide 3-D conformal, locally targeted hyperthermia concomitant to radiotherapy in the uterine cervix. The catheter-based device is integrated within a HDR brachytherapy applicator to facilitate sequential and potentially simultaneous heat and radiation delivery. Methods: Treatment planning images from 35 patients who underwent HDR brachytherapy for locally advanced cervical cancer were inspected to assess the dimensions of radiation clinical target volumes (CTVs) and gross tumor volumes (GTVs) surrounding the cervix and the proximity of organs at risk. Biothermal simulation was used to identify applicator and catheter material parameters to adequately heat the cervix with minimal thermal dose accumulation in nontargeted structures. A family of ultrasound applicators was fabricated with two to three tubular transducers operating at 6.6-7.4 MHz that are unsectored (360 deg.), bisectored (2x180 deg.), or trisectored (3x120 deg.) for control of energy deposition in angle and along the device length in order to satisfy anatomical constraints. The device is housed in a 6 mm diameter PET catheter with cooling water flow for endocervical implantation. Devices were characterized by measuring acoustic efficiencies, rotational acoustic intensity distributions, and rotational temperature distributions in phantom. Results: The CTV in HDR brachytherapy plans extends 20.5{+-}5.0 mm from the endocervical tandem with the rectum and bladder typically <8 mm from the target boundary. The GTV extends 19.4{+-}7.3 mm from the tandem. Simulations indicate that for 60 min treatments the applicator can heat to 41 deg. C and deliver >5EM{sub 43 Degree-Sign C} over 4-5 cm diameter with T{sub max}<45 deg. C and 1 kg m{sup -3} s{sup -1} blood perfusion. The 41 deg. C contour diameter is reduced to 3-4 cm at 3 kg m{sup -3} s{sup -1} perfusion. Differential power control to transducer elements and sectors demonstrates tailoring of heating along the device length and in angle. Sector cuts are associated with a 14-47 deg. acoustic dead zone, depending on cut width, resulting in a {approx}2-4 deg. C temperature reduction within the dead zone below T{sub max}. Dead zones can be oriented for thermal protection of the rectum and bladder. Fabricated devices have acoustic efficiencies of 33.4%-51.8% with acoustic output that is well collimated in length, reflects the sectoring strategy, and is strongly correlated with temperature distributions. Conclusions: A catheter-based ultrasound applicator was developed for endocervical implantation with locally targeted, 3-D conformal thermal delivery to the uterine cervix. Feasibility of heating clinically relevant target volumes was demonstrated with power control along the device length and in angle to treat the cervix with minimal thermal dose delivery to the rectum and bladder.

60 APPLIED LIFE SCIENCES↗

DIFFUSIVE ACCELERATION OF PARTICLES AT OBLIQUE, RELATIVISTIC, MAGNETOHYDRODYNAMIC SHOCKS

Diffusive shock acceleration (DSA) at relativistic shocks is expected to be an important acceleration mechanism in a variety of astrophysical objects including extragalactic jets in active galactic nuclei and gamma-ray bursts. These sources remain good candidate sites for the generation of ultrahigh energy cosmic rays. In this paper, key predictions of DSA at relativistic shocks that are germane to the production of relativistic electrons and ions are outlined. The technique employed to identify these characteristics is a Monte Carlo simulation of such diffusive acceleration in test-particle, relativistic, oblique, magnetohydrodynamic (MHD) shocks. Using a compact prescription for diffusion of charges in MHD turbulence, this approach generates particle angular and momentum distributions at any position upstream or downstream of the shock. Simulation output is presented for both small angle and large angle scattering scenarios, and a variety of shock obliquities including superluminal regimes when the de Hoffmann-Teller frame does not exist. The distribution function power-law indices compare favorably with results from other techniques. They are found to depend sensitively on the mean magnetic field orientation in the shock, and the nature of MHD turbulence that propagates along fields in shock environs. An interesting regime of flat-spectrum generation is addressed; we provide evidence for it being due to shock drift acceleration, a phenomenon well known in heliospheric shock studies. The impact of these theoretical results on blazar science is outlined. Specifically, Fermi Large Area Telescope gamma-ray observations of these relativistic jet sources are providing significant constraints on important environmental quantities for relativistic shocks, namely, the field obliquity, the frequency of scattering, and the level of field turbulence.

79 ASTRONOMY AND ASTROPHYSICS↗

Reduced Order Models Generation for HTGRs Pebble Shuffling Procedure Optimization Studies

This report provides an initial study for producing reduced-order models (ROMs) of pebble-bed high temperature gas reactor (HTGR) models for the purposes of design optimization. As an initial study, this work is meant to be exploratory---identifying useful workflows and methods for ROM generation---and not meant to be a catch-all analysis of HTGR ROM generation and usage for optimization. This report summarizes three tasks performed in Fiscal Year 2022: 1) the creation of HTGR model, 2) the sensitivity analysis of model design parameters, and 3) an introduction to ROM generation techniques. The representative HTGR model created in this work is a multiphysics equilibrium-core using the BlueCRAB (comprehensive reactor analysis bundle) reactor analysis application, coupling four physical phenomena: neutronics, streamline depletion, porous flow thermal hydraulics, and pebble heat conduction. Part of the model creation was identifying some design parameters and quantities of interest that are relevant in an optimization analysis and adjustable in the model. The sensitivity analysis utilized a polynomial chaos expansion methodology to compute global sensitivity metrics. This analysis showed that thermal hydraulics parameters and quantities of interest had a relatively small impact on simulation results. Finally, the ROM generation work involved exploring three different ROM methodologies: polynomial regression, a Gaussian process, and artificial neural networks. Using a cross-validation technique to characterize ROM performance, the Gaussian process and single-layer artificial neural networks showed the most promising results. Overall, this study was insightful and the lessons learned will be invaluable for the eventual development of an HTGR design optimization workflow.

97 MATHEMATICS AND COMPUTING↗

Low Cost Corrugated Substrates for High Efficiency OLEDs (Final Report)

The external quantum efficiency (EQE) of a planar OLED is limited to 25%. Around 75% of the light is trapped in the substrate, waveguided and SPP modes. In this project, we demonstrated that nano-structures can significantly improve the EQE of OLEDs. The objective is to improve the EQE to 70% using corrugated substrate, low index layer incorporation and micro lens arrays. We conducted optical study of the operating devices using ARES measurement, and used the result to guide the design of corrugated substrates as well as the OLED stack for better performance. During the first year of the program, we have demonstrated over 60% EQE in a corrugated green OLED with half-ball lens for light extraction. By comparing, the optical characteristics of OLEDs fabricated on single and poly crystal corrugated structures, we confirm that the enhancement using corrugated substrates comes from waveguided and SPP modes extraction. To push the device EQE to 70%, further optimization of the corrugated substrate is needed. The extraction of waveguided and SPP modes are influenced by the corrugation pitch, depth and profile. Therefore, we developed a series of processes to precisely control the corrugation morphology. Through comparison of different corrugated substrates, we observed that while an abrupt surface profile results in stronger mode extraction, it also introduces strong leakage current; while a smooth profile are less efficient in mode extraction, it preserves the quality of an OLED. Based on these observations, we conclude that a single crystal hole corrugation results in optimum EQE % and low leakage current when planarized with PEDOT. To improve the extraction of waveguided mode, we also introduce a low index contrast layer (ICL) to increase the index contrast between corrugated ITO and glass interface. We optimized our recipe for the index contrast layer processing and reduced its refractive index from 1.50 to 1.38. As a result, the optimized device shows 47.6% EQE, which is 1.64 times higher than the reference planar device. By extracting the substrate mode with a hemispherical lens, we obtained an EQE of 71.6%, which is a 2.46 times enhancement. The cross-section SEM image reveals the high EQE is due to the formation of an air gap at the interface of the ICL, resulting in an increase of the index contrast to Δn ~ 1. We use angle-resolved electroluminescence spectroscopy (ARES) to demonstrate that the ICL improves the diffraction efficiency at the ITO/glass interface, extracts TM, TE waveguide and SPP mode more efficiently, and leads to the observed high efficiency. We also address the directional emission issue with the single crystalline microlens arrays (MLAs) by fabricating polycrystalline MLAs. The process uses colloidal assembly method to create a mono-layer of silica spheres, then uses PDMS stamps to replicate the pattern for multi-use imprinting. The MLAs are close-packed in short range but have random orientations in the long range. This avoids stronger extraction along the optical axes of single crystal MLAs and prevents the directional emission issue. We also demonstrate that the color shift induced by the corrugation can be minimized using MLAs. In this scenario, the MLAs work as diffuser to randomize the directional emission from extracted waveguide and SPP modes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of prone versus supine 18F-FDG-PET of locally advanced breast cancer: Phantom and preliminary clinical studies

Purpose: Previous studies have demonstrated how imaging of the breast with patients lying prone using a supportive positioning device markedly facilitates longitudinal and/or multimodal image registration. In this contribution, the authors’ primary objective was to determine if there are differences in the standardized uptake value (SUV) derived from [{sup 18}F]fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) in breast tumors imaged in the standard supine position and in the prone position using a specialized positioning device. Methods: A custom positioning device was constructed to allow for breast scanning in the prone position. Rigid and nonrigid phantom studies evaluated differences in prone and supine PET. Clinical studies comprised 18F-FDG-PET of 34 patients with locally advanced breast cancer imaged in the prone position (with the custom support) followed by imaging in the supine position (without the support). Mean and maximum values (SUV{sub peak} and SUV{sub max}, respectively) were obtained from tumor regions-of-interest for both positions. Prone and supine SUV were linearly corrected to account for the differences in 18F-FDG uptake time. Correlation, Bland–Altman, and nonparametric analyses were performed on uptake time-corrected and uncorrected data. Results: SUV from the rigid PET breast phantom imaged in the prone position with the support device was 1.9% lower than without the support device. In the nonrigid PET breast phantom, prone SUV with the support device was 5.0% lower than supine SUV without the support device. In patients, the median (range) difference in uptake time between prone and supine scans was 16.4 min (13.4–30.9 min), which was significantly—but not completely—reduced by the linear correction method. SUV{sub peak} and SUV{sub max} from prone versus supine scans were highly correlated, with concordance correlation coefficients of 0.91 and 0.90, respectively. Prone SUV{sub peak} and SUV{sub max} were significantly lower than supine in both original and uptake time-adjusted data across a range of index times (P < < 0.0001, Wilcoxon signed rank test). Before correcting for uptake time differences, Bland–Altman analyses revealed proportional bias between prone and supine measurements (SUV{sub peak} and SUV{sub max}) that increased with higher levels of FDG uptake. After uptake time correction, this bias was significantly reduced (P < 0.01). Significant prone-supine differences, with regard to the spatial distribution of lesions relative to isocenter, were observed between the two scan positions, but this was poorly correlated with the residual (uptake time-corrected) prone-supine SUV{sub peak} difference (P = 0.78). Conclusions: Quantitative 18F-FDG-PET/CT of the breast in the prone position is not deleteriously affected by the support device but yields SUV that is consistently lower than those obtained in the standard supine position. SUV differences between scans arising from FDG uptake time differences can be substantially reduced, but not removed entirely, with the current correction method. SUV from the two scan orientations is quantitatively different and should not be assumed equivalent or interchangeable within the same subject. These findings have clinical relevance in that they underscore the importance of patient positioning while scanning as a clinical variable that must be accounted for with longitudinal PET measurement, for example, in the assessment of treatment response.

60 APPLIED LIFE SCIENCES↗

Integration of Online Cross-Section Generation Capability with Depletion and Transient Solvers in Griffin

Griffin is a Multiphysics Object-Oriented Simulation Environment (MOOSE)-based reactor multiphysics analysis application jointly developed by Argonne and Idaho National Laboratories under the DOENE Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. In FY25, an online crosssection generation capability based on the Self-Shielding Application Programming Interface (SSAPI) was demonstrated for TRISO-fueled reactor problems under steady-state conditions. This fiscal year, that capability was extended to support depletion and transient multiphysics calculations, enabling high-fidelity analyses that generate self-shielded cross sections on the fly from the actual evolving composition and temperature states rather than from pre-tabulated libraries. For depletion, a two-way coupling was established in which SSAPI computes compact-averaged self-shielded cross sections that the depletion solver then uses to advance the Bateman equations, with the updated compositions returned to SSAPI at each step; the depletion module was refactored to support both library-based and SSAPI-based cross sections, and additional logic was added to track daughter isotopes and to exclude minor isotopes for efficiency. For transient analysis, the SSAPI multigroup library was extended with the kinetics data required for time-dependent calculations, the Improved Quasi-Static (IQS) scheme was coupled with SSAPI, and several supporting capabilities were implemented, including a self-shielding treatment that lets control rods and drums move within a self-shielded model, which had previously been impossible and had ruled out rod- and drum-movement transients with on-the-fly cross sections altogether, a new mixing scheme for delayed-neutron precursor decay constants, a checkpoint-based restart workflow, and performance improvements such as pointwise cross-section interpolation and the bypassing of unnecessary Dancoff factor calculations. The implemented capabilities were verified against Serpent Monte Carlo solutions. For depletion, a prismatic pin-cell problem based on a Next Generation Nuclear Plant (NGNP) Very High Temperature Reactor benchmark showed excellent agreement, with eigenvalue differences within 200 pcm over the entire burnup range (up to 140 MWD/kgU) and fission-product and actinide inventories agreeing to within 0.8% and 2.5%, respectively; a heat-pipe microreactor assembly problem with a much higher fuel loading confirmed the same behavior and quantified the bias introduced when the multigroup equivalence effect is neglected. For transient analysis, a pin-cell problem with a step reactivity insertion and temperature feedback reproduced the analytically expected asymptotic power and showed close agreement between the direct and IQS solutions, and a two-dimensional microreactor core problem with control-drum rotation exercised the new moving-drum self-shielding treatment and demonstrated successful coupling of the online crosssection generation with both the direct and IQS transient methods. The capability was further exercised on a full-core pebble-bed problem, in which Griffin was coupled with the System Analysis Module (SAM) to simulate load-following operation of the gPBR with the Doppler feedback resolved at the TRISO fuel kernel temperature. These developments in Griffin provide a convenient, high-fidelity approach to cross-section generation for advanced thermal reactors with geometrically complex and highly heterogeneous configurations, including TRISO-fueled prismatic and pebble-bed systems, and support steady-state, depletion, and transient multiphysics calculations. They also enable self-shielded cross sections to be evaluated directly at the actual coupled state of the system, thereby establishing a foundation for high-fidelity, fully coupled multiphysics analysis of advanced reactors

Park, H.↗

WE-E-12A-01: Medical Physics 1.0 to 2.0: MRI, Displays, Informatics

Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidence-based medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. MRI 2.0: This presentation will look into the future of clinical MR imaging and what the clinical medical physicist will need to be doing as the technology of MR imaging evolves. Many of the measurement techniques used today will need to be expanded to address the advent of higher field imaging systems and dedicated imagers for specialty applications. Included will be the need to address quality assurance and testing metrics for multi-channel MR imagers and hybrid devices such as MR/PET systems. New pulse sequences and acquisition methods, increasing use of MR spectroscopy, and real-time guidance procedures will place the burden on the medical physicist to define and use new tools to properly evaluate these systems, but the clinical applications must be understood so that these tools are use correctly. Finally, new rules, clinical requirements, and regulations will mean that the medical physicist must actively work to keep her/his sites compliant and must work closely with physicians to ensure best performance of these systems. Informatics Display 1.0 to 2.0: Medical displays are an integral part of medical imaging operation. The DICOM and AAPM (TG18) efforts have led to clear definitions of performance requirements of monochrome medical displays that can be followed by medical physicists to ensure proper performance. However, effective implementation of that oversight has been challenging due to the number and extend of medical displays in use at a facility. The advent of color display and mobile displays has added additional challenges to the task of the medical physicist. This informatics display lecture first addresses the current display guidelines (the 1.0 paradigm) and further outlines the initiatives and prospects for color and mobile displays (the 2.0 paradigm). Informatics Management 1.0 to 2.0: Imaging informatics is part of every radiology practice today. Imaging informatics covers everything from the ordering of a study, through the data acquisition and processing, display and archiving, reporting of findings and the billing for the services performed. The standardization of the processes used to manage the information and methodologies to integrate these standards is being developed and advanced continuously. These developments are done in an open forum and imaging organizations and professionals all have a part in the process. In the Informatics Management presentation, the flow of information and the integration of the standards used in the processes will be reviewed. The role of radiologists and physicists in the process will be discussed. Current methods (the 1.0 paradigm) and evolving methods (the 2.0 paradigm) for validation of informatics systems function will also be discussed. Learning Objectives: Identify requirements for improving quality assurance and compliance tools for advanced and hybrid MRI systems. Identify the need for new quality assurance metrics and testing procedures for advanced systems. Identify new hardware systems and new procedures needed to evaluate MRI systems. Understand the components of current medical physics expectation for medical displays. Understand the role and prospect fo medical physics for color and mobile display devices. Understand different areas of imaging informatics and the methodology for developing informatics standards. Understand the current status of informatics standards and the role of physicists and radiologists in the process, and the current technology for validating the function of these systems.

07 ISOTOPE AND RADIATION SOURCES↗

Error-Induced Beam Degradation in Fermilab's Accelerators

In Part I, three independent models of Fermilab's Booster synchrotron are presented. All three models are constructed to investigate and explore the effects of unavoidable machine errors on a proton beam under the influence of space-charge effects. The first is a stochastic noise model. Electric current fluctuations arising from power supplies are ubiquitous and unavoidable and are a source of instabilities in accelerators of all types. A new noise module for generating the Ornstein-Uhlenbeck (O-U) stochastic noise is first created and incorporated into the existing Object-oriented Ring Beam Injection and Tracking (ORBIT-FNAL) package. After being convinced with a preliminary model that the noise, particularly non-white noise, does matter to beam quality, we proceeded to measure directly current ripples and common-mode voltages from all four Gradient Magnet Power Supplies (GMPS). Then, the current signals are Fourier-analyzed. Based upon the power spectra of current signals, we tune up the Ornstein-Uhlnbeck noise model. As a result, we are able to closely match the frequency spectra between current measurements and the modeled O-U stochastic noise. The stochastic noise modeled upon measurements is applied to the Booster beam in the presence of the full space-charge effects. This noise model, accompanied by a suite of beam diagnostic calculations, manifests that the stochastic noise, impinging upon the beam and coupled to the space-charge effects, can substantially enhance the beam degradation process throughout the injection period. The second model is a magnet misalignment model. It is the first time to utilize the latest beamline survey data for building a magnet-by-magnet misalignment model. Given as-found survey fiducial coordinates, we calculate all types of magnet alignment errors (station error, pitch, yaw, roll, twists, etc.) are implemented in the model. We then follow up with statistical analysis to understand how each type of alignment errors are currently distributed around the Booster ring. The ORBIT-FNAL simulations with space charge included show that rolled magnets, in particular, have substantial effects on the Booster beam. This survey-data-based misalignment model can predict how much improvement in machine performance can be achieved if prioritized or selected realignment work is done. In other words, this model can help us investigate different realignment scenarios for the Booster. In addition, by calculating average angular kicks from all misaligned magnets, we expect this misalignment model to serve as guidelines for resetting the strengths of corrector magnets. The third model for the Booster is a time-structured multi-turn injection model. Microbunch-injection scenarios with different time structures are explored in the presence of longitudinal space-charge force. Due to the radio-frequency (RF) bucket mismatch between the Booster and the 400-MeV transferline, RF-phase offsets can be parasitically introduced during the injection process. Using the microbunch multiturn injection, we carry out ESME-ORBIT-combined simulations. This combined simulation allows us to investigate realistic charge-density distribution under full space-charge effects. The growth rates of transverse emittances turned out to be 20 % in both planes. This microbunch-injection scenarios is also applicable to the future 8-GeV Superconducting Linac Proton Driver and the upgraded Main Injector at Fermilab. In Part II, the feasibility of momentum-stacking method of proton beams is investigated. When the Run2 collider program at Fermilab comes to an end around year 2009, the present antiproton source can be available for other purposes. One possible application is to convert the antiproton accumulator to a proton accumulator, so that the beam power from the Main Injector could be enhanced by a factor of four. Through adiabatic processes and optimized parameters of synchrotron motion, we demonstrate with an aid of the ESME code that up to four proton batches can be stacked in the momentum acceptance available for the Accumulator ring. This momentum-stacking method is expected to be a part of Fermilab's SuperNuMI (SNuMI) project.

43 PARTICLE ACCELERATORS↗

A new water-equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy

Purpose: The objective of this work is to present a new 2D plastic scintillation detectors array (2D-PSDA) designed for the dosimetry of megavoltage (MV) energy photon beams in radiation therapy and to characterize its basic performance. Methods: We developed a 2D detector array consisting of 781 plastic scintillation detectors (PSDs) inserted into a plane of a water-equivalent phantom. The PSDs were distributed on a 26 x 26 cm{sup 2} grid, with an interdetector spacing of 10 mm, except for two perpendicular lines centered on the detection plane, where the spacing was 5 mm. Each PSD was made of a 1 mm diameter by 3 mm long cylindrical polystyrene scintillating fiber coupled to a clear nonscintillating plastic optical fiber. All of the light signals emitted by the PSDs were read simultaneously with an optical system at a rate of one measurement per second. We characterized the performance of the optical system, the angular dependency of the device, and the perturbation of dose distributions caused by the hundreds of PSDs inserted into the phantom. We also evaluated the capacity of the system to monitor complex multileaf collimator (MLC) sequences such as those encountered in step-and-shoot intensity modulated radiation therapy (IMRT) plans. We compared our results with calculations performed by a treatment planning system and with measurements taken with a 2D ionization chamber array and with a radiochromic film. Results: The detector array that we developed allowed us to measure doses with an average precision of better than 1% for cumulated doses equal to or greater than 6.3 cGy. Our results showed that the dose distributions produced by the 6-MV photon beam are not perturbed (within {+-}1.1%) by the presence of the hundreds of PSDs located into the phantom. The results also showed that the variations in the beam incidences have little effect on the dose response of the device. For all incidences tested, the passing rates of the gamma tests between the 2D-PSDA and the treatment planning system were higher than 97.5% when the standard clinical tolerances of 3% or 3 mm were used. Excellent agreement was obtained between the doses measured and calculated when we used the 2D-PSDA for monitoring a MLC sequence from a step-and-shoot IMRT plan. Conclusions: We demonstrated the feasibility of using a large number of PSDs in a new 2D-PSDA for the dosimetry of MV energy photon beams in radiation therapy. The excellent precision, accuracy, and low angular dependence of the device indicate that such a prototype could potentially be used as a high-accuracy quality assurance tool for IMRT and arc therapy patient plan verification. The homogeneity and water-equivalence of the prototype we built suggest that this technology could be extended to multiple detection planes by arranging the fibers into more complex orientations, opening the possibility for 3D dosimetry with PSDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-E-9A-01: Medical Physics 1.0 to 2.0, Session 4: Computed Tomography, Ultrasound and Nuclear Medicine

Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidencebased medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. CT 2.0: CT has been undergoing a dramatic transition in the last few decades. While the changes in the technology merits discussions of their own, an important question is how clinical medical physicists are expected to effectively engage with the new realities of CT technology and practice. Consistent with the upcoming paradigm of Medical Physics 2.0, this CT presentation aims to provide definitions and demonstration of the components of the new clinical medical physics practice pertaining CT. The topics covered include physics metrics and analytics that aim to provide higher order clinicallyrelevant quantification of system performance as pertains to new (and not so new) technologies. That will include the new radiation and dose metrics (SSDE, organ dose, risk indices), image quality metrology (MTF/NPS/d’), task-based phantoms, and the effect of patient size. That will follow with a discussion of the testing implication of new CT hardware (detectors, tubes), acquisition methods (innovative helical geometries, AEC, wide beam CT, dual energy, inverse geometry, application specialties), and image processing and analysis (iterative reconstructions, quantitative CT, advanced renditions). The presentation will conclude with a discussion of clinical and operational aspects of Medical Physics 2.0 including training and communication, use optimization (dose and technique factors), automated analysis and data management (automated QC methods, protocol tracking, dose monitoring, issue tracking), and meaningful QC considerations. US 2.0: Ultrasound imaging is evolving at a rapid pace, adding new imaging functions and modes that continue to enhance its clinical utility and benefits to patients. The ultrasound talk will look ahead 10–15 years and consider how medical physicists can bring maximal value to the clinical ultrasound practices of the future. The roles of physics in accreditation and regulatory compliance, image quality and exam optimization, clinical innovation, and education of staff and trainees will all be considered. A detailed examination of expected technology evolution and impact on image quality metrics will be presented. Clinical implementation of comprehensive physics services will also be discussed. Nuclear Medicine 2.0: Although the basic science of nuclear imaging has remained relatively unchanged since its inception, advances in instrumentation continue to advance the field into new territories. With a great number of these advances occurring over the past decade, the role and testing strategies of clinical nuclear medicine physicists must evolve in parallel. The Nuclear Medicine 2.0 presentation is designed to highlight some of the recent advances from a clinical medical physicist perspective and provide ideas and motivation for designing better evaluation strategies. Topics include improvement of traditional physics metrics and analytics, testing implications of hybrid imaging and advanced detector technologies, and strategies for effective implementation into the clinic. Learning Objectives: Become familiar with new physics metrics and analytics in nuclear medicine, CT, and ultrasound. To become familiar with the major new developments of clinical physics support. To understand the physics testing implications of new technologies, hardware, software, and applications. Identify approaches for implementing comprehensive medical physics services in future imaging practices.

60 APPLIED LIFE SCIENCES↗