Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Floating zone melting of cadmium telluride

To produce superior crystals of cadmium telluride, floating zone melting in space has been proposed. Techniques required for floating zone melting of cadmium telluride are being developed. We have successfully float-zoned cadmium telluride on earth using square rods. A resistance heater was constructed for forming the molten zone. Evaporation of the molten zone was controlled by adding excess cadmium to the growth ampoule combined with heating of the entire ampoule. An effective method to hold the feed rod was developed. Slow rotation of the growth ampoule was proven experimentally to be necessary to achieve a complete symmetric molten zone. Most of the resultant cylindrical rods were single crystals with twins. Still needed is a suitable automatic method to control the zone length. We tried a fiber optical technique to control the zone length, but experiments showed that application of this technique to automate zone length control is unlikely to be successful.

Chang, Wen-Ming↗

Phase-resolving spin-wave microscopy using infrared strobe light

The need for sensitively and reliably probing magnetization dynamics has been increasing in various contexts such as studying novel hybrid magnonic systems, in which the spin dynamics strongly and coherently couple to other excitations, including microwave photons, light photons, or phonons. Recent advances in quantum magnonics also highlight the need for employing the magnon phase as quantum state variable, which is to be detected and mapped out with high precision in on-chip micro- and nanoscale magnonic devices. Here, in this study, we demonstrate a facile optical technique that can directly perform concurrent spectroscopic and imaging functionalities with spatial and phase resolutions, using infrared strobe light operating at 1550-nm wavelength. To showcase the methodology, we spectroscopically studied the phaseresolved spin dynamics in a bilayer of Permalloy and yttrium iron garnet Y 3 Fe 5 O 12 (YIG), and spatially imaged the backward-volume spin-wave modes of YIG in the dipolar spin-wave regime. Using the strobe light probe, the detected precessional phase contrast can be directly used to construct the map of the spin wave's wave front, in the continuous-wave regime of spin-wave propagation and in the stationary state, without needing any optical reference path. By selecting the applied field, frequency, and detection phase, the spin-wave images can be made sensitive to the precession amplitude and phase. Our results demonstrate that infrared optical strobe light can serve as a versatile platform for magneto-optical probing of magnetization dynamics, with potential implications in investigating hybrid magnonic systems.

Xiong, Yuzan [University of North Carolina, Chapel↗

Overview of the instrumentation program

This program is aimed at developing sensors and measurement systems capable of obtaining the data necessary for the verification of computational models of the structural behavior, the fatigue life, and the environmental conditions pertinent to advanced reusable space propulsion systems. One of the characteristics of measurement systems needed to verify codes is that the sensors must be nonintrusive or at least minimally intrusive so as not to significantly perturb the conditions being measured. This leads to a heavy emphasis on laser optical techniques and on thin-film sensors. Another characteristic of such instruments is that they must be highly accurate and produce very high spatial and temporal resolution of the parameter being measured. The measurement systems needed generally fall into a number of broad categories. First there are the measurements needed on the surfaces of components such as turbine blades and vanes. Some of the desired parameters are temperature, strain, and heat flux. Another broad category encompasses those measurements needed in the flow environment around these components. Here, the desired results are high resolution maps of such parameters as flow velocity, temperature, density, pressure, and species concentration. The remaining category deals with measurements necessary for monitoring the health of the engine. This category has loomed ever more important since the Challenger disaster. An optical method for determining the characteristics of the plume is presented. Holographic measurement of structural damage is also presented.

Nieberding, William C.↗

Numerical study of the effect of normalised window size, sampling frequency, and noise level on short time Fourier transform analysis

Photonic Doppler velocimetry, also known as heterodyne velocimetry, is a widely used optical technique that requires the analysis of frequency modulated signals. This paper describes an investigation into the errors of short time Fourier transform analysis. The number of variables requiring investigation was reduced by means of an equivalence principle. Error predictions, as the number of cycles, samples per cycle, noise level, and window type were varied, are presented. The results were found to be in good agreement with analytical models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tunable chiral and nematic states in the triple-Q antiferromagnet Co 1/3 TaS 2

Complex spin configurations in magnetic materials, ranging from collinear single-Q to non-coplanar multi-Q states, exhibit rich symmetry and chiral properties. However, their detailed characterization is often hindered by the limited spatial resolution of neutron diffraction techniques. Here we employ magnetic circular dichroism and magnetic linear dichroism to investigate the triangular lattice antiferromagnet Co 1/3 TaS 2 , revealing three-state (Z 3 ) nematicity and also spin chirality across its multi-Q magnetic phases. At intermediate temperatures, the presence of linear dichroism identifies nematicity arising from a single-Q stripe phase, while at high magnetic fields and low temperatures, a phase characterized solely by circular dichroism emerges, signifying a purely chiral non-coplanar triple-Q state. Notably, at low temperatures and small fields, we discover a unique phase where both chirality and nematicity coexist. A theoretical analysis based on a continuous multi-Q manifold captures the emergence of these distinct magnetic phases, as a result of the interplay between four-spin interactions and weak magnetic anisotropy. Additionally, both circular and linear dichroism microscopy spatially resolves the chiral and nematic domains. Our findings establish Co 1/3 TaS 2 as a rare platform hosting diverse multi-Q states with distinct combinations of spin chirality and nematicity while demonstrating the effectiveness of polarized optical techniques in characterizing complex magnetic textures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optical functions of uniaxial rutile and anatase (TiO 2 ) revisited

In this study, the optical functions of uniaxial rutile and anatase (TiO2) were determined from 200 to 850 nm (6.2 to 1.46 eV) using several of four optical techniques: (1) standard spectroscopic two-modulator generalized ellipsometry (2-MGE), (2) near-normal-incidence two-modulator generalized ellipsometry microscopy (2-MGEM), (3) Mueller matrix transmission of rutile, and (4) polarized transmission of rutile. The 2-MGE measurements yielded highly accurate values of the dielectric functions and error estimates from 1.46 to 6.2 eV, whereas the polarization-dependent transmission yielded more accurate values of the absorption coefficient below the band edge of rutile. The 2-MGEM also measured the diattenuation, which is related to the birefringence, and other parameters but at near-normal incidence at a single wavelength (577 nm).

36 MATERIALS SCIENCE↗

Large Spin-Orbit Torque in 𝑎-Plane 𝛼−Fe 2 ⁢O 3 /Pt Bilayers

Realization of efficient spin-orbit torque switching of the Neel vector in insulating antiferromagnets is a challenge, often complicated by spurious effects. Quantifying the spin-orbit torques in antiferromagnet or heavy metal heterostructures is an important first step toward this goal. Here, we employ magneto-optic techniques to study damping-like spin-orbit torque (DL-SOT) in a-plane α-Fe 2 O 3 (hematite) with a Pt spin-orbit overlayer. We find that the DL-SOT efficiency is 2 orders of magnitude larger than reported in c- and r-plane hematite/Pt using harmonic Hall techniques. The large magnitude of DL-SOT is supported by direct imaging of current-induced motion of antiferromagnetic domains that happens at moderate current densities. Furthermore, our study introduces a new method for quantifying spin-orbit torque in antiferromagnets with a small canted moment and identifies a-plane α-Fe 2 O 3 as a promising candidate to realize efficient SOT switching.

Antiferromagnetism↗

Ultrafast high-harmonic spectroscopy of solids

High-harmonic spectroscopy, an ultrafast all-optical technique initially conceptualized in atomic and molecular systems, has now emerged as a powerful platform for studying the structure and dynamics of condensed matter. Unlike that in the gas phase, solid-state high-harmonic generation relies on the fundamental response from high atomic density and periodicity, leading to interband transitions and coherent driving of electrons and holes in their respective bands. These mechanisms make high-harmonic spectroscopy particularly sensitive to the electronic band structure, topological properties and many-body correlations in condensed media. An advantage of high-harmonic spectroscopy over other spectroscopic methods is its ability to probe ultrafast phenomena, capturing femto- to attosecond dynamics of multi-band and strongly correlated electron interactions in solids. Furthermore, in this Review, we discuss the latest experimental and theoretical advances in ultrafast high-harmonic spectroscopy of solids and provide perspectives for future research in this field.

High-harmonic generation↗

Absorption and related optical dispersion effects on the spectral response of a surface plasmon resonance sensor

Surface plasmon resonance (SPR) sensing is an optical technique that allows real time detection of small changes in the physical properties, in particular in the refractive index, of a dielectric medium near a metal film surface. One way to increase the SPR signal shift is then to incorporate a substance possessing a strong dispersive refractive index in the range of the plasmon resonance band. In this paper, we investigate the impact of materials possessing a strong dispersive index integrated to the dielectric medium on the SPR reflectivity profile. We present theoretical results based on chromophore absorption spectra and on their associated refractive index obtained from the Lorentz approach and Kramers-Kroenig equations. As predicted by the theory, the experimental results show an enhancement of the SPR response, maximized when the chromophore absorption band coincides with the plasmon resonant wavelength. This shows that chromophores labeling can provide a potential way for SPR response enhancement.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Actively stabilized optical fiber interferometry technique for online/in-process surface measurement

In this paper, we report the recent progress in optical-beam scanning fiber interferometry for potential online nanoscale surface measurement based on the previous research. It attempts to generate a robust and miniature measurement device for future development into a multiprobe array measurement system. In this research, both fiber-optic-interferometry and the wavelength-division-multiplexing techniques have been used, so that the optical probe and the optical interferometer are well spaced and fast surface scanning can be carried out, allowing flexibility for online measurement. In addition, this system provides a self-reference signal to stabilize the optical detection with high common-mode noise suppression by adopting an active phase tracking and stabilization technique. Low-frequency noise was significantly reduced compared with unstabilized result. The measurement of a sample surface shows an attained repeatability of 3.3 nm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Shock experiments and numerical simulations on low energy portable electrically exploding foil accelerators

Two low energy (1.6 and 8 kJ) portable electrically exploding foil accelerators are developed for moderately high pressure shock studies at small laboratory scale. Projectile velocities up to 4.0 km/s have been measured on Kapton flyers of thickness 125 {mu}m and diameter 8 mm, using an in-house developed Fabry-Perot velocimeter. An asymmetric tilt of typically few milliradians has been measured in flyers using fiber optic technique. High pressure impact experiments have been carried out on tantalum, and aluminum targets up to pressures of 27 and 18 GPa, respectively. Peak particle velocities at the target-glass interface as measured by Fabry-Perot velocimeter have been found in good agreement with the reported equation of state data. A one-dimensional hydrodynamic code based on realistic models of equation of state and electrical resistivity has been developed to numerically simulate the flyer velocity profiles. The developed numerical scheme is validated against experimental and simulation data reported in literature on such systems. Numerically computed flyer velocity profiles and final flyer velocities have been found in close agreement with the previously reported experimental results with a significant improvement over reported magnetohydrodynamic simulations. Numerical modeling of low energy systems reported here predicts flyer velocity profiles higher than experimental values, indicating possibility of further improvement to achieve higher shock pressures.

43 PARTICLE ACCELERATORS↗

Evaluation of low-frequency operational limit of proposed ITER low-field-side reflectometer waveguide run including miter bends

The present design concept for the ITER low-field-side reflectometer transmission line (TL) consists of an ~40 m long, 6.35 cm diameter helically corrugated waveguide (WG) together with ten 90° miter bends. This paper presents an evaluation of the TL performance at low frequencies (33-50 GHz) where the predicted HE11 mode ohmic and mode conversion losses start to increase significantly. Quasi-optical techniques were used to form a near Gaussian beam to efficiently couple radiation in this frequency range into the WG. We observed that the output beams from the guide remained linearly polarized with cross-polarization power levels of ~1.5%-3%. The polarization rotation due to the helical corrugations was in the range ~1°-3°. The radiated beam power profiles typically show excellent Gaussian propagation characteristics at distances >20 cm from the final exit aperture. The round trip propagation loss was found to be ~2.5 dB at 50 GHz and ~6.5 dB at 35 GHz, showing an inverse increase with frequency. This was consistent with updated calculations of miter bend and ohmic losses. At low frequencies (33-50 GHz), the mode purity remained very good at the exit of the waveguide, and the losses are perfectly acceptable for operation in ITER. Finally, the primary challenge may come from the future addition of a Gaussian telescope and other filter components within the corrugated guide, which will likely introduce additional perturbations to the beam profile and an increase in mode-conversion loss.

47 OTHER INSTRUMENTATION↗

Micro-photoluminescence mapping and Chemometrics for the rapid classification of rare earth materials

This article introduces advancements in chemically mapping rare earth materials using photoluminescence (PL) and chemometrics. By leveraging the high sensitivity and selectivity of PL compared to alternative optical techniques, as well as its compatibility with microscopy, we present enhanced capabilities for noninvasive material screening and characterization. Exemplary PL spectra of samarium(III) and europium(III) in oxide, nitrate, and chloride forms demonstrated the ability to extract detailed chemical information of diverse rare earth particles. Additionally, we introduced efficient PL mapping sequences capable of covering a 9 mm diameter carbon tab within minutes, which highlighted the benefits of rapid, large-area imaging. Furthermore, an integrated approach combining PL mapping with principal component analysis and a random forest classifier enabled the resolution of overlapping spectral peaks from different chemistries and provided accurate material classification. In conclusion, these advancements underscored the versatility and robustness of PL for chemically mapping rare earth materials, with the potential to support applications in mining, energy, environmental monitoring, isotope production and beyond.

Chemometrics↗

Raman-shifting an ArF excimer laser to generate new lines for obtaining optical diagnostic based information in flow fields

The application of tunable excimer lasers in combustion and flow diagnostics is almost routine nowadays. The properties of this laser system that enable density and temperature measurements in supersonic and hypersonic flow fields to be conducted are its high power, high repetition rate, and high spectral brightness. The limitation imposed by this system on these measurements is the paucity of lines in the wavelength region, the vacuum-ultraviolet, where species of interest, such as OH, N2, O2, H2, H2O, CO, NO, etc., are susceptible to electronic excitation to high-lying states. To circumvent this problem one normally resorts to nonlinear optical techniques such as frequency conversion via stimulated Raman scattering (SRS), more commonly known as Raman shifting or Raman mixing, to extend these nonintrusive and nonperturbing techniques to the shorter wavelengths in the VUV region and, for that matter, to longer wavelengths in the infrared region, if the need arises. The theoretical basis of SRS and its application are well documented in the literature. In essence, the Raman shift is a consequence of the inelastic scattering of the incident radiation by the sample. Most of the scattered radiation from the molecules of the sample is unchanged in frequency. However, a small fraction of the incident radiation is changed in frequency. This shift is a result of the fact that some of the incident photons on colliding with the molecules of the sample give up some of their energy and emerge with a lower energy resulting in the lower-frequency Stokes radiation. Other incident photons may increase their energy by colliding with the vibrationally excited molecules of the medium and emerge as higher-frequency antistokes radiation. The generation of the latter is the main objective of this project. The process, however, depends on several factors, including the beam quality of the pump laser, the cross-section of the gaseous medium, the gas pressure, and the ambient temperature of the gas near the focal region. Furthermore, since the Raman shifting process is polarization sensitive, it is necessary to have all of the laser energy in a single polarization. These factors were taken into consideration in the execution of the project. The implementation of the Raman shift was accomplished by focusing the 193 nm output of an ArF excimer laser (Lamda-Physik LPX 150) into a 1-meter long high pressure recirculating Raman cell filled with H2 gas. The laser system was modified in order to improve the mode quality of the pump beam to enhance the Raman shifting. To accomplish this feat, a prism beam expander and grating on the oscillator discharge provided wavelength tuning over the excimer gain profile. Furthermore, a triple-pass configuration, as opposed to unstable resonator optics, was employed in the operation of the amplifier cavity so that when the oscillator output radiation, focused by a 51-cm focal length fused silica lens through a 50 micron pinhole (serving as a spatial filter) and recollimated with a 25-cm focal length lens, was fed into the amplifier, it was injection locked, thereby providing tunable radiation with relatively low divergence. The forward scattered radiation emanating from the impingement of the modified pump beam on the Raman cell was detected using an energy meter after the latter had been separated from it using a dispersing prism.

Koker, Edmond B.↗

Multi-Scale Integrated Monitoring System for Enhancing Methane Emission Detection, Quantification & Prediction

This report details the progress and findings of a comprehensive study on reviewing existing solutions, identifying technology gaps, and formulating an “all-in-one” integrated strategy for developing the next-generation multiscale methane monitoring and modeling platform, conducted under grant number DE-FE0032292. Co-led by Dr. David Ebert, Dr. Binbin Weng, and Dr. Chenghao Wang at the University of Oklahoma, the project’s goal was to develop an integrated approach for building this engineering platform to detect, quantify, and mitigate methane emissions across various temporal scale, spatial scales, and sectors. The planning grant study began with an extensive review of various methane sensing and monitoring technologies and systems, surveying over 100 technology providers globally. This review revealed the prevalence of optical methods over chemical methods in commercially available sensors, with Non-Dispersive Infrared (NDIR), Tunable Diode Laser Absorption Spectroscopy (TDLAS), and Optical Gas Imaging (OGI) cameras being the most prevalent options. A trend towards more advanced optical techniques was observed, driven by increased regulatory focus and technological advancements. The technical evaluation of these sensing technologies provided crucial insights into their capabilities and limitations. The study examined emerging technologies such as Differential Absorption LiDAR (DIAL), which show promise for high-precision and long-range detection. The team then investigated the features and application bandwidth of various sensing platforms, including handheld, fixed/stationary, mobile, aerials, and spaceborne monitors. Pilot field studies were conducted to assess the capabilities of solutions for different emission scenarios. Field work with sensor deployments was conducted at three distinct site types: an oil & gas industry site, a cattle ranching operation, and a waste processing facility. The team also conducted a thorough review of methane flux inverse modeling approaches, focused on physically based methods. These approaches were categorized into simple, intermediate, and advanced methods. A realtime WRF-GHG (Weather Research and Forecasting-Greenhouse Gas) modeling system was developed and applied, incorporating multiple data sources to guide field experiments and inform methane plume detection. The project identified and analyzed numerous categories of methane data sources, including satellite measurements, ground-based sensors, and inventory databases. Key platforms examined include EDGAR, EPA GHGI, NASA TROPOMI, Carbon Mapper, and Climate TRACE, among others. The team proposed an architecture for a comprehensive methane monitoring platform. This system incorporates multi-source data acquisition, advanced data processing and assimilation, interactive visualization tools, and analytical capabilities for emissions forecasting and scenario analysis. The proposed platform aims to provide a user-friendly interface catering to various stakeholders, from researchers to policymakers. The architecture includes sophisticated data ingestion methods, a centralized data warehouse, and advanced analytical tools for data fusion and interpretation. To ensure the relevance and effectiveness of the proposed system, a comprehensive survey was conducted to gather stakeholder input on system requirements. Key findings include a strong need for integrating various data types and formats, a preference for real-time data updates and advanced visualization tools, and a demand for user-friendly interfaces catering to different expertise levels.

03 NATURAL GAS↗

Lasers, extreme UV and soft X-ray

Three decades ago, large ICF lasers that occupied entire buildings were used as the energy sources to drive the first X-ray lasers. Today X-ray lasers are tabletop, spatially coherent, high-repetition rate lasers that enable many of the standard optical techniques such as interferometry to be extended to the soft X-ray regime between wavelengths of 10 and 50 nm. Over the last decade X-ray laser performance has been improved by the use of the grazing incidence geometry, diode-pumped solid-state lasers, and seeding techniques. The dominant X-ray laser schemes are the monopole collisional excitation lasers either driven by chirped pulse amplification (CPA) laser systems or capillary discharge. The CPA systems drive lasing in neon-like or nickel-like ions, typically in the 10 – 30 nm range, while the capillary system works best for neon-like argon at 46.9 nm. Most researchers use nickel-like ion lasers near 14 nm because they are well matched to the Mo:Si multilayer mirrors that have peak reflectivity near 13 nm and are used in many applications. As a result, the last decade has seen the birth of the X-ray free electron laser (XFEL) that can reach wavelengths down to 0.15 nm and the inner-shell Ne laser at 1.46 nm.

42 ENGINEERING↗

Optical, Electrical, and Magnetic Studies of Organic Solar Cells Based on Low Bandgap Copolymer with Spin ½ Radical Additives

The charge photogeneration and recombination processes in organic photovoltaic solar cells based on blend of the low bandgap copolymer, PTB7 (fluorinated poly‐thienothiophene‐benzodithiophene) with C60‐PCBM using optical, electrical, and magnetic measurements in thin films and devices is studied. A variety of steady state optical and magneto‐optical techniques were employed, such as photoinduced absorption (PA), magneto‐PA, doping‐induced absorption, and PA‐detected magnetic resonance (PADMR); as well as picosecond time‐resolved PA. The charge polarons and triplet exciton dynamics in films of pristine PTB7, PTB7/fullerene donor–acceptor (D–A) blend is followed. It is found that a major loss mechanism that limits the power conversion efficiency (PCE) of PTB7‐based solar cell devices is the “back reaction” that leads to triplet exciton formation in the polymer donor from the photogenerated charge‐transfer excitons at the D–A interfaces. A method of suppressing this “back reaction” by adding spin½ radicals Galvinoxyl to the D–A blend is presented; this enhances the cell PCE by ≈30%. The same method is not effective for cells based on PTB7/C70‐PCBM blend, where high PCE is reached even without Galvinoxyl radical additives.

Basel, Tek↗

3D Lifetime Tomography Reveals How CdCl 2 Improves Recombination Throughout CdTe Solar Cells

When using two-photon tomography, carrier lifetimes are mapped in polycrystalline CdTe photovoltaic devices. These 3D maps probe subsurface carrier dynamics that are inaccessible with traditional optical techniques. They reveal that CdCl 2 treatment of CdTe solar cells suppresses nonradiative recombination and enhances carrier lifetimes throughout the film with substantial improvements particularly near subsurface grain boundaries and the critical buried p-n junction.

14 SOLAR ENERGY↗