Search NASA⌕ Search

SEARCH · Search NASA

Results for “penetration testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Critical mineral substitutions in IN617: A combined computational and experimental approach to performance evaluation and feasibility

Addressing the escalating demand for critical minerals (CMs) driven by global climate change initiatives, this study explores compositional modifications to Inconel 617 (IN617) by substituting cobalt (Co) with manganese (Mn) across various atomic percentages. Here, we conducted a computational feasibility study employing Molecular Dynamics (MD) simulations to provide strategic guidance for experimental validation. The simulations analyzed tensile strength and corrosion resistance for five modified compositions (M1 to M5) to identify optimal properties. Tensile tests on cubic simulation cells were performed to generate stress-strain curves, revealing the impact of Co replacement with Mn on tensile strength—a metric correlated with hardness. Oxygen penetration simulations were conducted to evaluate corrosion resistance, indicating that reduced oxygen penetration depth corresponds to enhanced resistance. Promising compositions underwent phase diagram calculations for assessing phase stability. The optimal composition (M1), characterized by high tensile strength and minimal oxygen penetration, was chosen for experimental validation using induction melting and friction stir consolidation techniques. The materials were further characterized using SEM-EDS, XRD, and Vickers hardness testing. Our findings suggest that Mn substitution in IN617 can yield mechanical performance at par with high-Co alloys in energy-critical applications.

36 MATERIALS SCIENCE↗

Evaluation of a locally homogeneous flow model of spray combustion

A model of spray combustion which employs a second-order turbulence model was developed. The assumption of locally homogeneous flow is made, implying infinitely fast transport rates between the phase. Measurements to test the model were completed for a gaseous n-propane flame and an air atomized n-pentane spray flame, burning in stagnant air at atmospheric pressure. Profiles of mean velocity and temperature, as well as velocity fluctuations and Reynolds stress, were measured in the flames. The predictions for the gas flame were in excellent agreement with the measurements. The predictions for the spray were qualitatively correct, but effects of finite rate interphase transport were evident, resulting in a overstimation of the rate development of the flow. Predictions of spray penetration length at high pressures, including supercritical combustion conditions, were also completed for comparison with earlier measurements. Test conditions involved a pressure atomized n-pentane spray, burning in stagnant air at pressures of 3, 5, and 9 MPa. The comparison between predictions and measurements was fair. This is not a very sensitive test of the model, however, and further high pressure experimental and theoretical results are needed before a satisfactory assessment of the locally homogeneous flow approximation can be made.

Mao, C. P.↗

Procedure Developed for Ballistic Impact Testing of Composite Fan Containment Concepts

The fan-containment system in a jet engine is designed to prevent a fan blade from penetrating the engine case in the event that the blade or a portion of the blade separates from the rotor during operation. Usually, these systems consist of a thick metal case that is strong enough to survive such an impact. Other systems consist of a dry aramid fabric wrapped around a relatively thin metal case. In large turbofan engines, metal-containment systems can weigh well over 300 kg, and there is a strong impetus to reduce their weight. As a result, the NASA Lewis Research Center is involved in an effort to develop polymer matrix composite (PMC) fan-containment systems to reduce the weight and cost while maintaining the high levels of safety associated with current systems. Under a Space Act Agreement with AlliedSignal Aircraft Engines, a new ballistic impact test procedure has been developed to quantitatively evaluate the performance of polymer matrix composite systems.

Pereira, J. Michael↗

Hypervelocity Impacts on ISS Handrails and Evaluation of Alternative Materials to Prevent Extravehicular Mobility Unit (EMU) Glove Damage During EVA

During post-flight processing of STS-116, damage to crewmember Robert Curbeam's Phase VI Glove Thermal Micrometeoroid Garment was discovered. This damage consisted of: loss of RTV-157 palm pads on the thumb area on the right glove, a 0.75 inch cut in the Vectran adjacent to the seam and thumb pad (single event cut), constituting the worst glove damage ever recorded for the U.S. space program. The underlying bladder and restraint were found not be damaged by this event. Evaluation of glove damage found that the outer Vectran fibers were sliced as a result of contact with a sharp edge or pinch point rather than general wear or abrasion (commonly observed on the RTV pads). Damage to gloves was also noted on STS-118 and STS-120. One potential source of EMU glove damages are sharp crater lips on external handrails, generated by micrometeoroid and orbital debris (MMOD) impacts. In this paper, the results of a hypervelocity impact (HVI) test program on representative and actual ISS handrails are presented. These tests were performed in order to characterize impact damage profiles on ISS handrails and evaluate alternatives for limiting risk to future missions. It was determined that both penetrating and non-penetrating MMOD impacts on aluminum and steel ISS handrails are capable of generating protruding crater profiles which exceed the heights required for EMU glove abrasion risk by an order of magnitude. Testing demonstrated that flexible overwraps attached to the outside of existing handrails are capable of limiting contact between hazardous crater formations and crewmember gloves during extravehicular activity (EVA). Additionally, replacing metallic handrails with high strength, low ductility, fiber reinforced composite materials would limit the formation of protruding crater lips on new ISS modules.

Ryan, Shannon↗

High Temperature Permeability of Carbon Cloth Phenolic Composite

The carbon fiber phenolic resin composite material used for the RSRM nozzle insulator occasionally experiences problems during operation from pocketing or spalling-like erosion and lifting of plies into the char layer. This phenomenon can be better understood if the permeability of the material at elevated temperatures is well defined. This paper describes an experimental approach to determining high temperature permeability of the carbon phenolic material used as the RSRM nozzle liner material. Two different approaches were conducted independently using disk and bar type specimens with the designed permeability apparatus. The principle of the apparatus was to subject a test specimen to a high pressure differential and a heat supply and to monitor both the pressure and temperature variations resulting from gas penetration through the permeable wall between the two chambers. The bar types, especially designed to eliminate sealing difficulties at a high temperature environment, were directly exposed to real time temperature elevation from 22 C to 260 C during the test period. The disk types were pre-heat treated up to 300 C for 8 hours and cooled to room temperature before testing. Nonlinear variation of downstream pressure at a certain temperature range implied moisture release and matrix pyrolysis. Permeability was calculated using a semi-numerical model of quasi-steady state. The test results and the numerical model are discussed in the paper.

Park, O. Y.↗

The Characteristics of Fatigue Damage in the Fuselage Riveted Lap Splice Joint

An extensive data base has been developed to form the physical basis for new analytical methodology to predict the onset of widespread fatigue damage in the fuselage lap splice joint. The results of detailed destructive examinations have been cataloged to describe the physical nature of MSD in the lap splice joint. ne catalog includes a detailed description, e.g., crack initiation, growth rates, size, location, and fracture morphology, of fatigue damage in the fuselage lap splice joint structure. Detailed examinations were conducted on a lap splice joint panel removed from a full scale fuselage test article after completing a 60,000 cycle pressure test. The panel contained a four bay region that exhibited visible outer skin cracks and regions of crack link-up along the upper rivet row. Destructive examinations revealed undetected fatigue damage in the outer skin, inner skin, and tear strap regions. Outer skin fatigue cracks were found to initiate by fretting damage along the faying surface. The cracks grew along the faying surface to a length equivalent to two to three skin thicknesses before penetrating the outboard surface of the outer skin. Analysis of fracture surface marker bands produced during full scale testing revealed that all upper rivet row fatigue cracks contained in a dim bay region grow at similar rates; this important result suggests that fracture mechanics based methods can be used to predict the growth of outer skin fatigue cracks in lap splice structure. Results are presented showing the affects of MSD and out-of-plane pressure loads on outer skin crack link-up.

Piascik, Robert S.↗

Flammability of photovoltaic modules

A series of Class B burning-brand tests were performed on experimental modules using high-temperature, back-surface materials to develop the technology base required to construct fire-ratable modules. Results indicate the existence of synergistic relationships between hydrocarbon encapsulation materials and the experimental module configurations that provide increased fire resistance. These configurations use Kapton, fiberglass, neoprene rubber, stainless-steel foil or aluminum foil as the back surface. Successful test results occur when the structural integrity of the module back surface is maintained. Test failures of these modules always occur for one of three reasons: the outermost back cover melts, rips, or is too porous. In each case flammable molten encapsulant, its gaseous byproducts, or both, penetrates the back surface of the module and bursts into flame. Future efforts to complete the technology base will concentrate on the spread-of-flame test, focusing on the more promising configurations identified in the initial series of tests.

Sugimura, R. S.↗

Short efficient ejector systems

A research program was conducted to improve the performance of low pressure ratio ejector systems. The results show that short, efficient ejectors operating at nearly ideal performance are possible through the use of forced mixer lobes. Forced mixer lobes generate large scale axial vorticity which results in rapid mixing and improved diffuser performance. Ejector testing was conducted using both an ejector wind tunnel. Numerous mixer lobe variations were tested to develop lobe design guidelines. The improved performance of mixer-ejectors is presented over a range of operating conditions. Results of mixer lobe angle, penetration, and alignment are presented. Lobe angles of up to 25 deg, coupled with diffuser wall angles over 20 deg, operate without separation, allowing efficient, short ejector systems. Both warm and cold flow test results are presented. Temperature similarity expressions previously developed are further formulated and verified.

Presz, Walter M., Jr.↗

High strain rate nanoindentation testing: Recent advancements, challenges and opportunities

Recent advancements in electronics have renewed the interest in high strain rate nanoindentation testing, resulting in the development of new high strain rate nanoindentation test equipment and test methodologies. Here, in this work, the current state-of-the-art in high strain rate nanoindentation testing is critically reviewed, with focus on three key aspects - the testing equipment's dynamic mechanical and electronic response, test methodology, and post-processing of raw data to obtain hardness and strain rate. The challenges in instrument hardware design and post-test data analysis are discussed, along with optimal strain rate window for accurate high strain rate measurements. Specific focus will be on instrumented high strain rate testing using self-similar indenters at strain rates in excess of 100 s -1 , wherein load and depth of penetration into the sample are both measured or applied.

36 MATERIALS SCIENCE↗

Compatibility Tests Between the Mars Vehicle System Test Bed and RIMFAX Radar Antenna Prototype for the Mars 2020 Mission

NASA's Mars 2020 rover will carry a wideband (150 megahertz to 1200 megahertz) ground penetrating radar—RIMFAX (Radar Imager for Mars’ subsurFace eXperiment ), contributed by FFI (Forsvarets forskningsinstitutt) of Norway—to survey the subsurface geology of Mars. RIMFAX will take radar soundings while the rover drives across the Martian terrain, which presents possible compatibility issues between rover and radar operations. In order to study this risk, a prototype RIMFAX antenna was attached to the flight-analogous rover Vehicle System Test Bed (VSTB) in a mechanically representative location. The prototype antenna collected spectral and time-domain data across a variety of driving operations in order to assess the radar sensitivity to rover-generated noise. Conversely, the prototype antenna was driven while an engineering-model UHF (Ultra High Frequency) antenna used for rover telecom measured received in-band power to ensure that the rover hardware was not at risk of damage. Evaluation of the data by the instrument science team showed that while rover noise was apparent to the receiver, data post-processing would yield greater than 40 decibels margin to the science requirements. Similarly, power levels received by the UHF antenna were well below damage thresholds.

Gonzales, Edward↗

Flight test of an infrared wind shear detector

The topics are presented in viewgraph form and include the following: 5 microburst core penetrations; Airborne Warning and Avoidance System 3 (AWAS 3) overall performance; and issues of concern.

Mckissick, Burnell T.↗

Fuel-Cladding Eutectic Study of Legacy Fast Flux Test Facility (FFTF) MFF HT9/U-10Zr Metallic Fuel

This report presents the first systematic investigation of fuel-cladding eutectic interaction (FCEI) in irradiated HT9/U-10Zr metallic fuel from the Fast Flux Test Facility (FFTF) Materials Fuels Form (MFF) program, using differential scanning calorimetry (DSC) coupled with scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). Two irradiated fuel cross-sections, MNT07H (9.5 at% burnup, x/L = 0.78) and MNT08H (7.0 at% burnup, x/L = 0.93), were subjected to three successive isothermal annealing rounds (R1–R3) at 820°C for 20 minutes each, yielding a cumulative transient duration of one hour. This study directly addresses a recognized gap in the existing FCEI database, which previously lacked irradiated HT9/U-10Zr data at burnup levels above 8 at%. Two principal findings emerge from the study. First, for both samples, FCEI remained spatially confined within the pre-existing fuel-cladding chemical interaction (FCCI) zone boundaries after R3, with no measurable eutectic penetration into unaffected cladding beyond the original FCCI layer. This self-limiting behavior is consistent with historical Fuel Behavior Test Apparatus (FBTA) results and is attributed to the near-eutectic phase composition of the FCCI zone, which rapidly absorb the available eutectic-forming constituents and then stall penetration once the FCCI zone is consumed. A comparison with unirradiated surrogate data further supports this mechanism: whereas a U–34 at.% Fe sample would be expected to show ~176 µm of iron penetration under comparable conditions, the irradiated samples exhibited only ~20 µm, a discrepancy attributed to irradiation-induced interfacial porosity and pre-existing FCCI composition gradients. Second, for MNT08H, FCEI was observed exclusively on the half of the cladding circumference where pre-existing steady-state FCCI was present, with no detectable FCEI on the opposite half. Three hypotheses are proposed to explain this asymmetry: the inhibiting role of a zirconium-rich rind at the fuel-cladding interface; the chemical sequestration of iron by redistributed zirconium within the fuel matrix; and the persistence of fuel-cladding gaps on the FCEI-free half that preclude direct contact. All three hypotheses require further experimental investigation. The results extend the empirical FCEI database into higher-burnup territory and demonstrate the viability of DSC-based testing as a substitute for the no-longer-available FBTA apparatus. Future work will include additional cross-section testing, compilation of the full FCEI dataset, model evaluation, and DSC testing of ternary fuel compositions to broaden the experimental basis for safety assessment of sodium-cooled fast reactor systems.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Airport flammability, full scale fire tests

The primary objectives of the fire tests are: (1) conduct full scale test with 737 fuselages by the end of 1980; (2) demonstrate evacuation time increase to five minutes minimum; (3) show that exterior fire will not penetrate an intact cabin for five minutes; (4) show that closed cabin will not have excess smoke or temperatures above 400 F; and (5) demonstrate that fire in cabin opening will not propagate throughout cabin. The test program has three phases. A test schedule and status of required materials are presented.

Bricker, R. W.↗

Book Preservation

Books produced since 1850, held in the Library of Congress, have a very high acid content, hence a shorter life expectancy than prior-published volumes. A means of "deacidifying" books on a large, economically-viable scale is of great interest, particularly to the research library community, which stores millions of valuable, often irreplaceable documents. The General Electric vacuum chamber used in deacidification tests serves a dual purpose. It creates an environment in which DEZ can do its job without presence of oxygen and also dries the books. After the drying phase, DEZ is introduced to the chamber as a paper-penetrating vapor. The complete process typically takes eight days, four days for vacuum drying and four days of book exposure to DEZ. Accelerated aging tests showed that the process can extend paper life almost fourfold, even on color illustrations.

Source record↗

Wireless Instrumented RB Experiment Preliminary Design and Analysis

The ability to deploy new nuclear fuels for current or future reactor concepts requires carefully designed experiments to generate data to support fuel qualification. Ideally these experiments would include state of-the-art sensing to maximize the amount of in situ data that can be collected during operation. Furthermore, advanced reactor systems can take advantage of integrated in-core sensing technologies to maximize fuel utilization, reduce unnecessary conservativism in design margins, and improve operator’s understanding of limiting peaking factors. Before any novel sensing technologies can be readily adopted for nuclear applications, they must first demonstrate acceptable performance in test reactors. This report summarizes the preliminary design and analysis of the most highly instrumented irradiation experiment ever performed in the removable beryllium (RB) positions of the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). The Wireless Instrumented RB Experiment 2021 (WIRE-21) will test a wide range of sensors including wireless sensors being developed by Westinghouse Electric Company (WEC) that could provide in situ measurements of peak fuel temperatures and fuel rod pressurization due to fission gas release. The ability to wirelessly transmit a signal through the fuel rod’s cladding is critical to improving fuel monitoring capabilities without requiring signal penetrations through the cladding pressure boundary, which would significantly impact fuel fabrication, handling, and operation. Other sensors that will be tested in WIRE-21 include an array of thermocouples, self-powered neutron detectors (SPNDs), and spatially distributed fiber-optic temperature sensors. More generally, WIRE-21 will establish a flexible irradiation vehicle design to allow accelerated, economical testing of advanced sensor technologies while leveraging the extremely high neutron flux that is available in HFIR. This report summarizes the mechanical design for WIRE-21, the experimental test matrix, initial neutronic and thermal design analyses, and the active monitoring and control system enhancements necessary to support testing of advanced sensor technologies. The containment for WIRE-21 is similar to previous RB irradiation vehicles but includes a few modifications, most notably the use of integrated compression seals to pass a larger number of sensor leads through the experiment’s pressure boundary. In addition to the sensor leads, inert gas lines are passed into the experiment to enable active temperature control and the ability to pneumatically actuate a bellows-driven pressure sensor. WIRE-21 is targeting temperatures (300–350°C) and neutron fluence levels (~10 22 n/cm 2 ) relevant to light water reactors (LWRs), but the flexible design of the experiment vehicle allows much higher operating temperatures (>1,100°C). Neutronic calculations determine the neutron flux conditions as well as the nuclear heating within the experiments. These results are used as inputs to detailed thermal finite element calculations, which are required to evaluate the complex, three-dimensional heat transfer that occurs within WEC’s wireless sensor enclosures. Initial results show that the temperatures of the sensors’ enclosures and the metal bellows can be operated near the temperature range of LWR coolants and cladding while simultaneously increasing the temperature of a surrogate fuel material to values in the range of 800–1200°C to simulate centerline fuel temperatures during LWR operation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impact Modeling and Testing of Pouch and Prismatic Cells

Understanding battery response under impact is critical to improve the safety of electrified vehicles. Nevertheless, predicting the impact behaviors of batteries is not straightforward since a battery cell usually contains hundreds of thin layers with dramatically different material properties and multiple physical processes occur simultaneously during cell deformation. Here we utilized both empirical tests and numerical models to capture the failure process of pouch and prismatic cells in various impact scenarios. In each test, a cell was hit once by an indenter dropped from a certain height. During which the cell penetration, loading force, voltage and temperature were monitored to characterize the cell’s response. Meanwhile, numerical models were developed to capture the coupled mechanical, electrical, electrochemical and thermal responses of batteries. In these models, the cell bulk was treated as a homogeneous part to achieve computational efficiency required by large-scale simulations, and it was represented by the geologic cap model that allows both shear and compaction deformation. Simulation results showed agreement with experimental data in essential features of cell behaviors during impact. Details of the test setup, model development and cell failure behaviors are presented in this paper. Additionally, capabilities, limitations and future improvement of the battery safety modeling are discussed.

25 ENERGY STORAGE↗

Thermal Runaway of Li-Ion Cells: How Internal Dynamics, Mass Ejection, and Heat Vary with Cell Geometry and Abuse Type

Thermal runaway of lithium-ion batteries can involve various types of failure mechanisms each with their own unique characteristics. Using fractional thermal runaway calorimetry and high-speed radiography, the response of three different geometries of cylindrical cell (18650, 21700, and D-cell) to different abuse mechanisms (thermal, internal short circuiting, and nail penetration) are quantified and statistically examined. Correlations between the geometry of cells and their thermal behavior are identified, such as increasing heat output per amp-hour (kJ Ah −1 ) of cells with increasing cell diameter during nail penetration. High-speed radiography reveals that the rate of thermal runaway propagation within cells is generally highest for nail penetration where there is a relative increase in rate of propagation with increasing diameter, compared to thermal or internal short-circuiting abuse. For a given cell model tested under the same conditions, a distribution of heat output is observed with a trend of increasing heat output with increased mass ejection. Finally, internal temperature measurements using thermocouples embedded in the penetrating nail are shown to be unreliable thus demonstrating the need for care when using thermocouples where the temperature is rapidly changing. All data used in this manuscript are open access through the NREL and NASA Battery Failure Databank.

25 ENERGY STORAGE↗

Performance Evaluation of Data-Enhanced Hierarchical Control for Grid Operations

This paper presents a hardware-in-the-loop (HIL) simulation to evaluate the performance of voltage regulation of Data-Enhanced Hierarchical Control (DEHC). This DEHC uses an advanced distribution management system (ADMS) for grid operations to control legacy and grid-edge devices and coordinate with distributed energy management systems (DERMS) to manage high penetrations of photovoltaics (PV) on a utility distribution system. The HIL platform provides realistic laboratory testing, including accurate modeling (legacy devices, grid-edge devices, and PV) of the real-world distribution system from a utility partner, a real controller (ADMS), software controller DERMS, hardware grid-edge devices, and standard communications protocols. The test results demonstrate functionalities of the integrated platform and the performance of voltage regulation of the coordinated control systems. Based on laboratory testing, the utility can set up the same grid-automation system to manage DERs, legacy devices, and grid-edge devices to achieve their system-level control and operation objectives (e.g., voltage regulation), thus de-risking potential issues such as instability for field deployment.

41 EE - Solar Energy Technologies Office (EE-4S)↗