Search NASA⌕ Search

SEARCH · Search NASA

Results for “phase stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Simulation of Li-pellet triggered ELMs in EAST with an impurity model implemented under BOUT++ framework

A simple impurity model has been developed under the BOUT++ framework to investigate the Li-pellet triggered edge localized mode (ELM) in EAST configuration. The present impurity model decouples the ion pressure enhancement effect (IPEE) (which affects radial E X B flow shear and gyro-viscosity of deuterium ions and is implicitly included in our previous work) to make the simulation of Li pellet injection more physically reasonable. In addition, the present impurity model also includes the impurity equilibrium effect (IEE) (which induces modifications on vorticity and gyro-viscosity). The simulation results show that without IPEE a turbulent ELM induced by Li pellet is triggered by multiple peeling-ballooning modes (PBMs) rather than by a single dominant mode, and the simultaneous growth of multiple modes is conducive to reducing the time for pedestal entering the energy loss state. When a turbulent ELM occurs, the nonlinearly dominant modes undergo a secondary fast growth during fast crash phase. The finding explains the secondary increase of D α emission observed in the DIII-D Li injection experiments. During the evolution of a turbulent ELM, the continuous pedestal collapse dominates the pedestal energy loss in turbulent transport phase; however, in saturation phase, the stabilizing effects on PBMs (n ≠ 0) by n = 0 mode and radial E X B flow shear within the steepest gradient region are more prominent. It is also found that with IEE and without IPEE, the size threshold of ELM triggering and the magnitude of ELM sizes both show a good agreement with EAST and DIII-D experimental observations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hearing carrier-envelope offset frequency and phase in air with a microphone

Attosecond science and frequency metrology rely on the precise measurement and control of the laser pulse waveform, a feat traditionally achieved using optoelectronic techniques. In this study, we conducted a laser-induced acoustic experiment in air ionized by carrier-envelope phase (CEP)-stabilized sub-4 fs pulses. Our results reveal that the acoustic signal exhibits CEP dependence in few-cycle pulses, primarily through amplitude modulation from laser-driven ionization. This optoacoustic phenomenon is, to the best of our knowledge, a novel phenomenon that enables not only the measurement of the carrier-envelope offset frequency but also the direct characterization of the waveform of optical pulses through a microphone. Our study highlights the potential of laser-induced acoustic waves for advancing ultrafast science.

Han, Meng [Kansas State University, Manhattan, KS ↗

The effects of the Asselin time filter on numerical solutions to the linearized shallow-water wave equations

In the present investigation, a one-dimensional linearized analysis is used to determine the effect of Asselin's (1972) time filter on both the computational stability and phase error of numerical solutions for the shallow water wave equations, in cases with diffusion but without rotation. An attempt has been made to establish the approximate optimal values of the filtering parameter nu for each of the 'lagged', Dufort-Frankel, and Crank-Nicholson diffusion schemes, suppressing the computational wave mode without materially altering the physical wave mode. It is determined that in the presence of diffusion, the optimum filter length depends on whether waves are undergoing significant propagation. When moderate propagation is present, with or without diffusion, the Asselin filter has little effect on the spatial phase lag of the physical mode for the leapfrog advection scheme of the three diffusion schemes considered.

Schlesinger, R. E.↗

Cellular monotectic model solidification

Succinonitrile (sn) was purified to a superior level using a fractional recrystallization method. The melting point of the best twice recrystallized sn was not raised by following with double distillation. This was tested using differential scanning calorimetry. The peak shape on melting also proved that double distillation after double recrystallization did not improve the quality. Stability and phase diagrams for succinonitrile and glycerol are presented.

Kaukler, William F.↗

Effect of Zn additions on precipitation during aging of alloy 8090

Precipitation events have been observed by TEM under two different aging conditions in three 'stretched' alloys, whose compositions are encompassed by the 8090 composition window but contain Zn additions of up to 1.07 wt pct. DSC was also used to obtain deeper insight of the precipitation-event effects obtainable through Zn content variation; it was thereby revealed that Zn is incorporated into the delta-prime phase, perhaps stabilizing it. Coarse, Zn-containing precipitates can form on the boundaries and within the interiors of the grains, when the Zn content reaches the presently investigated maximum of 1.07 wt pct.

Kilmer, R. J.↗

Stability of the ordered orthorhombic phase in Ti-24Al-11Nb

The ordered orthorhombic 'O' phase in the Ti-Al-Nb ordered alloy system emerges either through slow cooling from above 1200 C or through isothermal aging after quenching from that temperature regime. An experimental investigation is presently conducted of the structural relationship between the O and alpha(2) phases, in order to clarify the mechanism of transition between the two. The transition occurs with the formation of a platelike alpha(2) phase within the O matrix, and may be characterized as due to a shape-deformation mechanism associated with diffusion of excess Nb away from the O/alpha(2) interface.

Hsiung, L. M.↗

Spacecraft signal sources portable test system

There is a frequent need to measure the frequency stability and phase noise levels of very high performance signal sources that are required for certain spacecraft missions. These measurements need to be done at different locations as the spacecraft subsystems progress through the various stages of development, assembly, test, and integration. Allan Deviation and Phase Noise of high performance sources are generally measured by comparing the unit under test to a reference standard. Five basic requirements are associated with making these kind of measurements: (1) the reference standard performance needs to be equal or better than the unit under test; (2) the measurement system needs to accommodate odd, nonstandard measurement frequencies that can range from 4 MHz to 35 GHz; (3) warm-up frequency drift and aging can corrupt a measurement and must be dealt with; (4) test equipment generated noise must be understood and prevented from limiting the measurements; (5) test equipment noise performance must be verifiable in the field as needed. A portable measurement system that was built by JPL and used in the field is described. The methods of addressing the above requirements are outlined and some measurement noise floor values are given. This test set was recently used to measure state of the art crystal oscillator frequency standards on the TOPEX and MARS OBSERVER spacecraft during several stages of acceptance tests.

Kirk, Albert↗

Pulsed acceleration in solar flares

We study the nonlinear dynamics of particle acceleration in solar flares by analyzing the time series of various quasi-periodic radio signatures during flares. In particular we present the radio and hard X-ray data of three flares which suppport the following tentative conclusions: (1) Particle acceleration and injection into magnetic structures occurs intrinsically in a pulsed mode (with a typical period of 1-2 s), produced by a single, spatially coherent, nonlinear system, rather than by a stochastic system with many spatially independent components ('statistical flare' produced by a fragmented primary energy release). (2) The nonlinear (quasi-periodic) mode of pulsed particle acceleration and injection into a coronal loop can be stabilized by phase locking with an MHD wave (oscillation) mode, if both periods are close to each other. (3) Pulsed injection of electron beams into a coronal loop may trigger nonlinear relaxational oscillations of wave-particle interactions. This is particularly likely when the limit cycles of both systems are similar.

Aschwanden, Markus J.↗

MgSiO3-FeSiO3-Al2O3 in the Earth's lower mantle: Perovskite and garnet at 1200 km depth

Natural pyroxene and garnet starting material are used to study the effects of joint Fe and Al substitution into MgSiO3 perovskite at approxmiately 50 GPa. Garnet is found to coexist with perovskite in samples containing both Fe and Al to pressures occurring deep into the lower mantel (approximately 1200 km depth). The volume of the perovskite unit cell is V(sub o(Angstrom(exp 3)) = 162.59 + 5.95x(sub FeSiO3) + 10.80x(sub Al2O3) with aluminum causing a significant increase in the distortion from the ideal cubic cell. On the basis of a proposed extension of the MgSiO3-Al2O3 high-pressure phase diagram toward FeSiO3, Fe is shown to partition preferentially into the garnet phase. The stability of garnet deep into the lower mantel may hinder the penetration of subducted slabs below the transition zone.

O'Neill, Bridget↗

Thermal Stability Analysis for a Heliocentric Gravitational Radiation Detection Mission

The Laser Interferometer Space Antenna (LISA) mission is designed for detailed studies of low-frequency gravitational radiation. The mission is currently a candidate for ESA's post-Horizon 2000 program. Thermal noise affects the measurement in at least two ways. Thermal variation of the length of the optical cavity to which the lasers are stabilized introduces phase variations in the interferometer signal, which have to be corrected for by using data from the two arms separately.

Laser Interferometer Space Antenna LISA gravitatio↗

NASA Tech Briefs, January 2010

Topics covered include: Cryogenic Flow Sensor; Multi-Sensor Mud Detection; Gas Flow Detection System; Mapping Capacitive Coupling Among Pixels in a Sensor Array; Fiber-Based Laser Transmitter for Oxygen A-Band Spectroscopy and Remote Sensing; Low-Profile, Dual-Wavelength, Dual-Polarized Antenna; Time-Separating Heating and Sensor Functions of Thermistors in Precision Thermal Control Applications; Cellular Reflectarray Antenna; A One-Dimensional Synthetic-Aperture Microwave Radiometer; Electrical Switching of Perovskite Thin-Film Resistors; Two-Dimensional Synthetic-Aperture Radiometer; Ethernet-Enabled Power and Communication Module for Embedded Processors; Electrically Variable Resistive Memory Devices; Improved Attachment in a Hybrid Inflatable Pressure Vessel; Electrostatic Separator for Beneficiation of Lunar Soil; Amorphous Rover; Space-Frame Antenna; Gear-Driven Turnbuckle Actuator; In-Situ Focusing Inside a Thermal Vacuum Chamber; Space-Frame Lunar Lander; Wider-Opening Dewar Flasks for Cryogenic Storage; Silicon Oxycarbide Aerogels for High-Temperature Thermal Insulation; Supercapacitor Electrolyte Solvents with Liquid Range Below -80 C; Designs and Materials for Better Coronagraph Occulting Masks; Fuel-Cell-Powered Vehicle with Hybrid Power Management; Fine-Water-Mist Multiple-Orientation-Discharge Fire Extinguisher; Fuel-Cell Water Separator; Turbulence and the Stabilization Principle; Improved Cloud Condensation Nucleus Spectrometer; Better Modeling of Electrostatic Discharge in an Insulator; Sub-Aperture Interferometers; Terahertz Mapping of Microstructure and Thickness Variations; Multiparallel Three-Dimensional Optical Microscopy; Stabilization of Phase of a Sinusoidal Signal Transmitted Over Optical Fiber; Vacuum-Compatible Wideband White Light and Laser Combiner Source System; Optical Tapers as White-Light WGM Resonators; EPR Imaging at a Few Megahertz Using SQUID Detectors; Reducing Field Distortion in Magnetic Resonance Imaging; Fluorogenic Cell-Based Biosensors for Monitoring Microbes; A Constant-Force Resistive Exercise Unit; GUI to Facilitate Research on Biological Damage from Radiation; On-Demand Urine Analyzer; More-Realistic Digital Modeling of a Human Body; and Advanced Liquid-Cooling Garment Using Highly Thermally Conductive Sheets.

Source record↗