Search NASA⌕ Search

SEARCH · Search NASA

Results for “power grid operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

A reinforcement learning approach to long-horizon operations, health, and maintenance supervisory control of advanced energy systems

In this work, we develop a Reinforcement Learning (RL) approach to the supervisory control problem for advanced energy systems, such as novel nuclear reactors and other demand-driven, mission-critical, and component-health-sensitive energy plants. The inclusive problem landscape considered captures the stochastic confluence of plant performance, component health evolution, power demand from the grid, diverse maintenance actions, and operator-defined goals and constraints, all considered over meaningfully long-enough reasoning horizons. Key aspects of the proposed approach are a receding horizon control-inspired technique dictating time- or event-triggered supervisory policy (re-)constructions, as well as additional capability-enabling contributions such as timescale compression, to handle long reasoning horizons and uncertainty in parts of the problem, and practical yet demonstrably-effective handling of hybrid action spaces with continuous and discrete decision variables. The resulting algorithm consists of a simulation-based RL agent constructing stochastic supervisory control policies over nontrivial action spaces and for long horizons, applying the learned policy to the system for a much shorter interval, and perpetually repeating, to construct the next long-horizon policy. That next policy will only be applied, again, for a short interval, yet originally far-in-time events move progressively closer, their associated uncertainty decreases, and new events and aspects enter the reasoning horizon. The proposed methodology bridges fundamental receding horizon concepts with the unequivocally stronger and more scalable reasoning of contemporary RL. Numerical examples using Soft Actor–Critic Deep RL illustrate the operation and efficacy of the proposed technique for a power plant tasked with health-aware load following missions in a dynamic electricity market landscape.

97 MATHEMATICS AND COMPUTING↗

A Reinforcement Learning Approach to Augment Conventional PID Control in Nuclear Power Plant Transient Operation

The ability of nuclear reactors to operate their power conversion cycles more flexibly will enhance their value to energy grids with variable pricing. Current nuclear control systems are typically classical controllers that are often based on proportional-integral-derivative (PID) control. This paper presents a method of augmenting the existing PID control for difficult transient operations in nuclear power plants using a reinforcement learning–derived feedforward signal applied in real time. The agents, which are trained on a test thermal load-following problem, are designed to improve steam generator outlet temperature control for a range of fast load-following scenarios covering ramp rates from 9%/min to 15%/min. Several reinforcement learning algorithms were initially investigated for the training of the feedforward agents with deep Q-learning (DQN) and proximal policy optimization (PPO) networks, which were found to be the most promising. The DQN controllers utilize discrete actions, giving them a better disturbance rejection at steady state but inconsistent response to initial temperature deviations. In contrast, PPO-trained agents, which take continuous actions except for a dead zone around zero, were shown to have the best combination of high disturbance rejection at steady state and good tracking of the desired temperature value. The ability of the PPO agent was also examined, with the average time of decision making found to be on the order of 1 ms. The fault properties of the controller under the loss of the reinforcement learning agent feedforward signal were also examined. The controller showed strong performance in situations of “no-signal” faults. but was less good at handling “stuck-at” faults, where the feedforward signal remains at a set value. In both cases, however, the PID was able to successfully maintain stability, eventually returning the system to a steady state. It is hoped that this work will allow for the proposed control architecture to be examined for more difficult control problems such that it may eventually be used to adapt existing nuclear plants for more aggressive load-following on grids of the future.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

EMOS (Energy Management Optimization System) [SWR-21-46]

EMOS software performs a real-time hierarchal optimal control for energy systems like multi-port electric vehicles charging site with distributed energy resources (DERs) and energy storage systems (ESSs). It gathers information in real-time from electric vehicles, power grid, and DERs, solves a multi-objective energy management optimization problem, and output setpoint for chargers, ESS converters, DERs converters, and grid converters. The software incorporates a novel integration of two control tasks: a) An Energy Management Optimization (EMO), which is the brain of EMOS controller that gathers information in real-time from EVs [e.g., battery size, state-of-charge (SOC), desired SOC, and charge acceptance curve], grid (e.g., electricity price, allowed feeder capacity, ramp rate limit, and reactive power), and DERs (e.g., prediction for solar generation for PV systems). It solves a control optimization problem in real-time to find optimal setpoint for ESSs power dispatch, EVs charging rate, and grid inverters. The objectives are to (1) minimize the charging cost considering grid energy, demand charges, and battery energy, (2) minimize charging time to meet fast charging criterion, (3) keep high energy level on ESSs at the end of an operating period, while satisfying constraints related to grid, EVs, and power converters. b) Real-Time Energy Management System (RT-EMS) is a rule-based algorithm that has faster response than EMO. It receives optimal setpoint from EMO and actual measurements from the system and modify the setpoint to compensate for any fast disturbance in the system, until a new optimum solution is received. Fast disturbances may include vehicle connect/disconnect, unpredicted variation in DERs profiles, variation in grid voltage, errors in PV generation prediction, and others. In addition, RT-EMS regulates voltage at point of common coupling (PCC) by managing reactive power of grid converters.

Mohamed, Ahmed↗

Cyber-Resilient Frequency Control of Power Grids with Energy Storage Systems

The integration of synchronous generators and energy storage systems operated through communication networks introduces new challenges and vulnerabilities to the electric grid, where cyber attacks can corrupt sensor measurements or control inputs and interrupt functions such as frequency regulation. This paper proposes a defense methodology for the design of resilient operating constraints imposed on each generation and storage unit in order to prevent any attack sequence from driving the system's frequency to unsafe conditions. The resilient operating constraints are found by using ellipsoidal approximations of the reachable set of the power system, leading to a convex optimization problem with linear matrix inequalities. Numerical results in a single-area power system with synchronous generation and energy storage demonstrate how the resilient constraints provide security guarantees against any type of attack affecting frequency measurements or controller setpoints.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stability Analysis of Parallel Connected Bidirectional WPT System

This paper presents a stability analysis of parallel-connected bi-directional series-series resonant network wireless power transfer (WPT), optimized for Electric Vehicle (EV) charging and vehicle-to-grid (V2G) applications. The study addresses critical stability challenges in systems integrated with diverse distributed energy resources (DERs), including photovoltaics, fuel cells, wind turbines, energy storage systems, and the AC grid. The stability of such integrated DC grid systems is paramount for ensuring reliable operation, particularly under varying power flow conditions and dynamic interactions between parallel WPT systems. The analysis included system impedance characterization, state-space modeling, and open and closed-loop stability evaluations. The results demonstrated that the integration of a robust control architecture effectively mitigates instability risks and supports scalable, efficient operation. This work underscores the converter's adaptability and its potential for large-scale deployment in wireless EV charging infrastructures and integrated DC grid systems.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

Sandia Nuclear Cartridge Concept

Nuclear power offers the promise of long-term electrical power for remote areas. Recent advances in passive safety and long-life cores make a reactor that can be operated autonomously for 20 years or more a real possibility. This white paper discusses a reactor concept that offers the potential for further development, resulting in a permanently hermetically-sealed "nuclear cartridge." The term "nuclear cartridge" is meant to imply a nuclear energy source that can be inserted into a site and operated autonomously until its energy has been depleted, then withdrawn and replaced by another cartridge. The concept can be scaled for various sizes, ranging from about 1 megawatt-electric (MWe) to about 100 MWe. The paper also discusses the concept of Integrated Safety, Operations, Security, and Safeguards (ISOSS) by design as it applies to this reactor design. Finally, a discussion of smart grids and how they can benefit the transfer of power to the end user is included. The Nuclear Cartridge concept has been developed with the following characteristics in mind: highly reliable autonomous operation coupled with international monitoring, requiring minimal on-site operations personnel; walkaway passively safe design; cartridge replacement cycle on the order of 20 years; load following capability; physical security by design requiring minimal security personnel during operations; and proliferation resistance by design. As illustrated in figure 1, integrating the reactor with advanced power conversion, smart grids, and other sources of energy results in a resilient and sustainable energy source.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Impacts on California of Expanded Regional Cooperation to Operate the Western Grid (Final Report)

Policy makers in California and other western states are exploring options for greater regional cooperation in managing the western power grid to better achieve public policy goals. This report, requested by the California State Assembly and commissioned by the California Independent System Operator (CAISO), reviews and summarizes recent proposals, studies, and papers addressing various modes of regional cooperation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Safe Reinforcement Learning for Emergency Load Shedding of Power Systems

The paradigm shift in the electric power grid necessitates a revisit of existing control methods to ensure the grid’s security and resilience. In particular, the increased uncertainties and rapidly changing operational conditions in power systems have revealed outstanding issues in terms of either speed, adaptiveness, or scalability of the existing control methods for power systems. On the other hand, the availability of massive real-time data can provide a clearer picture of what is happening in the grid. Recently, deep reinforcement learning (RL) has been regarded and adopted as a promising approach leveraging massive data for fast and adaptive grid control. However, like most existing machine learning (ML)- based control techniques, RL control usually cannot guarantee the safety of the power systems. In this paper, we introduce a novel method for safe RL-based load shedding of power systems that can enhance the safe voltage recovery of the electric power grid after experiencing faults. Numerical simulation on the IEEE 39-bus testcase is performed to demonstrate the effectiveness of the proposed safe RL emergency control, as well as its adaptive capability to faults not seen in the training.

reinforcement learning, emergency control, power g↗

Realistic Synthetic Distribution Grids: Summary of Validation Results

The presentation slides will walk us through the validation process and results of the synthetic distribution grid data. The synthetic grids for the distribution systems were developed as part of the ARPA-E funded GRIDDATA program project, SMART-DS. Three large scale datasets for US style distribution system were developed: 1) SAF: Santa Fe urban region, 2) GSO: Greensboro urban, semi-urban and industrial region, and 3) SFO: San Francisco Bay Area urban, semi-urban, industrial and rural areas. These datasets were validated using a three-pronged validation process, including statistical, operational and expert validation phases; the results of which have been summarized in this deck.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Data-Driven Algorithm for Enabling Delay Tolerance in Resilient Microgrid Controls Using Dynamic Mode Decomposition

The increased implementation of smart grid technologies in the power distribution grid presents unique opportunities that enable resiliency, but also brings challenges motivating needs for novel solutions and mitigation techniques. The bi-directional power and data flow allow for the grid to operate with increased resiliency, which is the ability to avoid discontinuity of service to end-use loads during extreme events. However, in applications where control of the distribution grid or microgrid relies on communication networks, the degradation of communication systems in the form of loss or high latency can cause maloperation and result in loss of end-use loads. Here this paper presents a novel framework to enable delay tolerance of centralized microgrid control schemes to mitigate communication system latency impacts and guarantee successful control action. We demonstrate the delay tolerance on a control scheme that operates a battery energy storage system (BESS) to offset the sudden loss of generation and maintain system frequency. During periods of severely degraded communication system performance, the proposed delay-tolerant algorithm compensates for the latency by utilizing a data-driven model generated at the device level using dynamic mode decomposition (DMD) to determine the performance of the communications. The DMD technique predicts the system’s frequency using device-level terminal measurements and provides updated control signals. The HELICS cosimulation platform evaluates the cyber-physical interaction of the power system model in GridLAB-D, the centralized control agent in Python, and the discrete network model in NS-3. The framework is tested and validated on the IEEE-123 node system modified to represent a networked remote microgrid model, and the results show an improvement in the dynamic performance

24 POWER TRANSMISSION AND DISTRIBUTION↗

Validation of Power Distribution Models using Load Flow Analysis in an ADMS Environment

Electric utilities are facing the need for better monitoring, analysis, and control of their distribution systems. An accurate mathematical model is a key to both the development of cutting-edge, scalable model-based algorithms and the assessment of emerging technologies such as distributed energy resources (DER) for grid planning and operation. However, the constantly evolving nature of power distribution systems poses challenges to maintaining accurate models. In this paper, we propose a novel load flow based approach to validate power distribution models. Networked equipment models described according to the Common Information Model (CIM) standard and a measurement model are used to formulate the distribution load flow problem. First, a system admittance matrix (Ybus) is derived from device-level CIM parameters. Next, the operational parameters (dynamic Ybus and nodal injections) are extracted from the measurement model using sensor configuration and equipment state. An iterative power flow method is then used to compute nodal voltages and branch flows that are compared against the measurement data to find any inconsistencies in the networked equipment model. This approach is implemented within GridAPPS-D, an open-source standards-based platform for advanced distribution management system (ADMS) application development, and demonstrated on the IEEE 13-bus, 123-bus, and 8500-node test feeders.

Common information model, model validation, power ↗

BIL GRID-READY WIND: Reliable and Economical Grid Services Design, Implementation, and Demonstration at the Great Pathfinder Wind Power Plant

The GRID-READY WIND project aimed to demonstrate the ability of utility-scale wind power plants (WPPs) to deliver traditional and emerging grid services (GSs) in both grid-following (GFL) and grid-forming (GFM) modes through a centralized control framework, supplemented by local control adjustments at the wind turbine generator as needed. Throughout the project, the team offered recommendations on how the grid services demonstrated with WPPs could be applied to other inverter-based resources (IBRs), such as photovoltaic (PV) systems and battery energy storage systems (BESS), while considering the unique dynamics of these resources arising from their energy generation characteristics. The project sought to enhance the confidence of system operators (SOs) and planners in utilizing WPPs, alongside other IBRs such as PV plants and BESS, to provide essential grid services over extended periods under diverse operating conditions, thereby supporting their integration into the bulk power system.

17 WIND ENERGY↗

GridSTIX

SF-25-112 Grid-STIX is a comprehensive extension of the STIX (Structured Threat Information Expression) 2.1 ontology specifically designed for electrical grid cybersecurity applications. This ontology provides a standardized, machine-readable framework for modeling grid assets, operational technology devices, threats, vulnerabilities, supply chain risks, and security relationships in electrical power systems. ## Key Features - **Comprehensive Grid Coverage**: Physical assets, OT devices, grid components, sensors, and energy storage systems - **Zero Trust Architecture**: Policy decision points, enforcement points, trust brokers, and continuous monitoring - **AMI Infrastructure**: Advanced metering networks, head-end systems, mesh gateways, and MDM systems - **Advanced Security Modeling**: Attack patterns, vulnerabilities, mitigations, and supply chain risks - **Critical Grid Relationships**: Power flow, protection, control, and synchronization relationships - **Supply Chain Security**: Supplier modeling, country of origin tracking, and risk assessment - **Protocol Support**: DNP3, Modbus, IEC 61850, IEC 60870-5-104, OPC-UA, and IEEE standards - **Python Code Generation**: Automated STIX-compliant Python class generation from ontologies - **Interactive Visualization**: Enhanced HTML network graphs with grid-specific categorization - **STIX 2.1 Compliance**: Full compatibility with STIX threat intelligence ecosystem

Blakely, Benjamin [Argonne National Laboratory (AN↗

Advanced Solar and Load Forecasting Incorporating HD Sky Imaging (Phase III)

Due to rapidly changing sky conditions, the available solar irradiance for energy generation is subject to wide swings in amplitude. As the market penetration of solar energy continues to increase rapidly, these variations in solar power generation are beginning to have an impact on grid stability and increased wear on power switches. Solar power forecasting plays a critical role in operations for Independent System Operators (ISOs) and utilities. Accurate forecasts help maintain grid reliability, optimize generation from renewables, and reduce operating costs. Of particular interest to the ISOs and utilities are sudden changes in solar irradiance, termed “ramp events,” due to the movement of clouds. One significant impact of ramp events on the grid is additional ancillary service requirements necessary to manage such variability. Ramp events can also cause voltage fluctuations in the distribution grids and trigger actions of automated line equipment (e.g., tap changers), leading to additional maintenance costs. In high penetration solar regions, forecasts must be made for both transmission-connected and distribution-connected resources – either behind the meter or in front of it. Particularly for distributed solar energy resources, forecasting can be a challenge due to the lack of visibility of the energy resource. Brookhaven National Laboratory (BNL) has been working towards nowcasting Global Horizontal Irradiance (GHI) using low-cost technologies for several years now. The Solar NowCasting technology being developed by BNL is a 0 – 30 min solar “nowcasting” technology applicable to a scale covering both large generating facilities and residential, distributed solar installations that relies on a network of ground-based high-definition (HD) cameras and surface pyranometers. GHI forecasts are being produced for both regions using 8 ground-based HD cameras and at least 2 surface pyranometers. When stitched together, the camera images can be used to forecast the impact of clouds on available solar irradiance over a domain of ~50 km 2 . Phase I of the project was the engineering scale up conceptual design stage. Phase II was the initial field test and demonstration, in which the technology was scaled up by a factor of 20 times and successfully demonstrated in eastern Long Island. In Phase III, an additional forecasting network was added in upstate NY and both networks are currently being operated until at least a full year of data is gathered by the Albany network to allow for the collection of sufficient data to evaluate performance against the persistence and smart persistence models using the Solar Arbiter.

14 SOLAR ENERGY↗

Material Selection and Sizing of a Thermoelectric Generator (TEG) for Power Generation in a Self-Powered Heating System

By employing the high temperature heat source to directly generate the electricity needed to power auxiliary systems in a natural gas furnace, boiler or hot water heater, a “self-powered” heating system can provide several benefits. Compared with a traditional furnace, boiler or hot water heater, when overall fuel utilization is kept constant, the self-powered system will have a higher primary energy efficiency, lower operating costs, and dramatically improved building safety and resilience during electric grid outages. Furthermore, a self-powered heating system only has a single utility connection – natural gas, without an electric connection – thus simplifying installation. A thermoelectric generator can be used for direct energy conversion of thermal energy to electricity with no moving parts, which offers a very simple means to provide power for the self-powered heating system, and the operation is without noise or vibration and can thus provide a very long system life. This paper provides an analysis focused on materials selection and the thermal power requirements for a thermoelectric generator (TEG) for use in a self-powered heating system. The dimensionless figure of merit for thermoelectric materials, zT, is used to estimate the optimal efficiency that can be achieved with a TEG to produce the electric power required in such an application. Comparisons of the predicted efficiency, the required heat transfer rate to the TEG and the heat transfer area needed for sustained operation under thermal conditions relevant to the self-powered heating application are made for several potential thermoelectric materials. This analysis was used to develop system requirements for a self-powered hot water heater using a TEG for electric power generation.

Laclair, Tim↗

Optimal Energy Dispatch of Distributed PVs for the Next Generation of Distribution Management Systems

Advanced Distribution Management Systems (ADMS) are being widely adopted by electric utilities for managing and optimizing the operations of their distribution systems. Distributed photovoltaic (DPV) systems with smart inverters can be controlled to adjust active power and reactive power outputs, and they are envisioned to become a part of (centrally or distributed) controllable assets managed by the ADMS for optimizing grid operations. This paper proposes an optimal energy dispatch strategy controlling DPV systems for regulating distribution voltages and achieving conservation voltage reduction. A convex optimization model is proposed with the use of linearized power flow, and the gradient projection algorithm is used to solve the optimal active power and reactive power outputs of smart inverters. The proposed optimal energy dispatch is implemented using an open-source ADMS platform, and simulation results have demonstrated the effectiveness of the proposed approach on improving distribution grid operations.

42 ENGINEERING↗

Data-Driven Modeling of High-Resolution Residential Load Profiles Using Low-Resolution Smart Meter Measurements

Accurate and high-resolution residential load profiles are essential for power system modeling, demand response planning, and effective grid operation. As the energy sector moves towards a more actively managed distribution system, the ability to understand residential energy consumption at a minute-by-minute scale becomes increasingly critical. High-resolution load profiles provide key insights into demand patterns and user behavior, enabling grid operators to design more effective energy solutions; however, residential load measurements in the field are typically recorded at low resolutions, such as 15-60 minutes, which makes it hard to study the characteristics of different residential customers. This paper addresses these challenges by introducing a data-driven approach to generate realistic, high-resolution residential load profiles based on lowre-solution measurements and weather information. The proposed method retains the key features of the actual residential load measurements while offering appliance-level energy consumption details for each residential building. The results demonstrate the effectiveness of the proposed load profile generator, proving its capability to support utilities in optimizing residential energy management and ensuring a more reliable and resilient grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗