Co-optimization to Integrate Power System Reliability Decisions with Resiliency Decisions.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Embodiments of the disclosure provide for hierarchically distributed voltage regulation and power flow optimization in a power distribution network. According to one embodiment, a regional coordinator system may determine power flow for an autonomous grid (AG) representing a portion of the distribution network based on a set of voltage parameters from nodes in the AG. The set of voltage parameters my include a current voltage magnitude. The regional coordinator system may provide, to a central controller system of the distribution network, one or more power flow parameters based on the determined power flow for the AG.
Abstract not provided.
Though the convex optimization has been widely used in power systems, it still cannot guarantee to yield a tight (accurate) solution to some problems. To mitigate this issue, this paper proposes an ensemble learning based convex approximation for alternating current (AC) power flow equations that differs from the existing convex relaxations. The proposed approach is based on three-phase quadratic power flow equations in rectangular coordinates. To develop this data-driven convex approximation of power flows, the polynomial regression (PR) is first deployed as a basic learner to fit convex relationships between the independent and dependent variables. Then, ensemble learning algorithms such as gradient boosting (GB) and bagging are introduced to combine learners to boost model performance. Based on the learned convex approximation of power flow, optimal power flow (OPF) is formulated as a convex quadratic programming problem. The simulation results on IEEE standard cases of both balanced and unbalanced systems show that, in the context of solving OPF, the proposed data-driven convex approximation outperforms the conventional semi-definite programming (SDP) relaxation in both accuracy and computational efficiency, especially in the cases that the conventional SDP relaxation fails
This paper proposes an energy management system (EMS) for nanogrids to balance the power supply and forecasted demand in consideration of forecasting errors arising from high instantaneous demand. The proposed EMS employs a power-balancing optimization process for forecasted demand and a reference power modulation strategy for forecasting errors. This power-balancing optimization utilizes nanogrid sources, such as photovoltaics, fuel cells, and batteries, to meet forecasted demand and a supercapacitor charging process to overcome issues with a low energy density. The proposed reference power modulation strategy is utilized to allocate power from a hybrid energy storage system consisting of a battery and supercapacitor in order to compensate for forecasting errors. In addition, this proposed strategy considers battery and supercapacitor constraints such as the power changing rate and total power limitations. Further, the power-balancing optimization process also operates at faster sampling rate than the reference power modulation process in order to improve the computational efficiency. The performance of the proposed EMS is evaluated using real data obtained from the Korea Electric Power Exchange.
This paper presents a model for improving off-design performance predictions for molten salt-driven Rankine power cycles, such as in concentrating solar power tower applications. The model predicts cycle off-design performance under various boundary conditions, including molten salt inlet temperature, mass flow rate, and ambient temperature. The model is validated using industry performance data and benchmarked with results from the literature. A complete concentrating solar power plant, inclusive of solar heliostat field and receiver, is then considered, by implementing the Rankine cycle off-design performance results into the National Renewable Energy Laboratory’s System Advisor Model software, which includes a tool that determines optimal power production schedules. The work improves upon the current System Advisor Model by updating off-design performance characteristics. A case study demonstrates the impact of cycle off-design behavior on annual performance for a stand-alone concentrating solar power system and a concentrating solar power-photovoltaic hybrid system. In addition, we demonstrate how cycle off-design performance influences optimal operator dispatch decisions and, thereby, overall system design and economics. We conclude that off-design cycle performance impacts “optimal” sub-system sizing, especially for a concentrating solar power-photovoltaic hybrid configuration in which concentrating solar power must dispatch in conjunction with photovoltaic generation.
A Brayton cycle was analyzed and optimized over the power range 60 - 140 kWe, for application to electric propulsion systems. A gas-cooled reactor heat source with exit temperature 1150 K was assumed. Power generation system specific masses (alpha) from 36 kg/kWe at 60 kWe to 22 kg/kWe at 140 kWe were obtained. These masses do not include the thrust production system, which is predicted to add 6 to 8 kg/kWe. Cycle efficiencies varied from 32% at 60 kWe to 36% at 140 kWe. Cycle minimum temperature, cycle pressure ratio, and heat exchanger design parameters were varied for the optimization. Optimization parameters and methods are described.
A comprehensive design study of a power supply for use in the space shuttle and other space flight applications is presented. The design specifications are established for a power supply capable of supplying over 90 percent of the anticipated voltage requirements for future spacecraft avionics systems. Analyses and tradeoff studies were performed on several alternative design approaches to assure that the selected design would provide near optimum performance of the planned applications. The selected design uses a dc-to-dc converter incorporating regenerative current feedback with a time-ratio controlled duty cycle to achieve high efficiency over a wide variation in input voltage and output loads. The packaging concept uses an expandable mainframe capable of accommodating up to six inverter/regulator modules with one common input filter module.
Evolutionary computing has proven to be a straightforward and robust approach for optimizing a wide range of difficult analysis and design problems. This paper discusses the application of these techniques to an existing space vehicle power subsystem resource and performance analysis simulation in a parallel processing environment.
Optimization study for high power inverters and converters
This study investigates the hosting capacity of the Banshee Distribution Network by optimizing the real power injection at carefully selected Distributed Energy Resource (DER) locations. The analysis is conducted within the framework of power system operational constraints, including bus voltage ranges, thermal line ratings, and transformer loading limits. A Python-based Genetic Algorithm (GA), implemented using the PyGAD library, is employed to iteratively identify the optimal power injection configuration that maximizes network utilization while preserving system reliability. The methodology integrates a real-time simulation environment using the Real-Time Digital Simulator (RTDS), allowing high-fidelity evaluation of power flow and voltage behavior under each proposed injection scenario. By coupling the optimization algorithm with real-time simulation feedback, this approach ensures that both static and dynamic constraints are enforced during the evaluation process. The GA leverages evolutionary operators such as selection, crossover, and mutation to navigate the nonlinear search space efficiently. The results of the study delineate the feasible hosting capacity at three targeted buses, reflecting maximum real power levels that can be injected without causing voltage violations, transformer overloading, or line congestion. These findings provide a decision- support tool for distribution planners and utilities aiming to integrate higher penetrations of DERs in existing infrastructure. Additionally, the work lays the foundation for extending such optimization techniques to multi-objective formulations, including economic dispatch and reactive power coordination, in future studies.
An optimization technique for generating antenna illumination tapers allows improved microwave transmission efficiencies from proposed solar power satellite (SPS) systems and minimizes sidelobe levels to meet preset environmental standards. The cumulative microwave power density levels from 50 optimized SPS systems are calculated at the centroids of each of the 3073 counties in the continental United States. These cumulative levels are compared with Environmental Protection Agency (EPA) measured levels of electromagnetic radiation in seven eastern cities. Effects of rectenna relocations upon the power levels/population exposure rates are also studied.
In this work, a multigeneration system is proposed for power, cooling and freshwater production. The waste heat from a SIEMENS SGT6-2000E GT is utilized to drive a supercritical CO 2 recompression Brayton cycle (SCRBC) and multi-effect desalination (MED) with thermal vapor compressor (TVC), while the waste heat from the pre-cooler of the SCRBC is utilized to drive an absorption cooling cycle. Detailed thermodynamic, exergy and exergoeconomic analyses are performed for the proposed multigeneration system using Engineering Equation Solver (EES). A sensitivity study is also performed to study the effects of the main operational parameters on the proposed system performance. Finally, multi-objective optimization using a genetic algorithm approach in EES is carried out to reach the optimal design. The proposed system can consume 34.2% less energy input and reduce CO 2 emission by 39.3% compared to the stand-alone systems for power, cooling and freshwater production. The results show that the energy utilization factor and exergy efficiency of the proposed system are improved by 33.6% and 14.3%, respectively, while the total unit product cost is reduced by 11.3% compared to the stand-alone GT cycle. Further, from exergoeconomic optimization, the proposed system can produce 132.4 MW of power, 7.09 MW of cooling and 650 kg/s of freshwater at energy utilization factor of 57.5%, exergy efficiency of 39.7% and total unit product cost of 16.3 $/GJ.
This study investigates the hosting capacity of the Banshee Distribution Network by optimizing the real power injection at carefully selected Distributed Energy Resource (DER) locations. The analysis is conducted within the framework of power system operational constraints, including bus voltage ranges, thermal line ratings, and transformer loading limits. A Python-based Genetic Algorithm (GA), implemented using the PyGAD library, is employed to iteratively identify the optimal power injection configuration that maximizes network utilization while preserving system reliability. The methodology integrates a real-time simulation environment using the Real-Time Digital Simulator (RTDS), allowing high-fidelity evaluation of power flow and voltage behavior under each proposed injection scenario. By coupling the optimization algorithm with real-time simulation feedback, this approach ensures that both static and dynamic constraints are enforced during the evaluation process. The GA leverages evolutionary operators such as selection, crossover, and mutation to navigate the nonlinear search space efficiently. The results of the study delineate the feasible hosting capacity at three targeted buses, reflecting maximum real power levels that can be injected without causing voltage violations, transformer overloading, or line congestion. These findings provide a decision- support tool for distribution planners and utilities aiming to integrate higher penetrations of DERs in existing infrastructure. Additionally, the work lays the foundation for extending such optimization techniques to multi-objective formulations, including economic dispatch and reactive power coordination, in future studies.
Optimized silicon solar cell development for spacecraft with near-sun missions
Prompt and effective corrective actions in response to unexpected contingencies are crucial for improving power system resilience and preventing cascading blackouts. The optimal load shedding (OLS) accounting for network limits has the potential to address the diverse system-wide impacts of contingency scenarios as compared to traditional local schemes. However, due to the fast cascading propagation of initial contingencies, real-time OLS solutions are challenging to attain in large systems with high computation and communication needs. In this paper, we propose a decentralized design that leverages offline training of a neural network (NN) model for individual load centers to autonomously construct the OLS solutions from locally available measurements. Our learning-for-OLS approach can greatly reduce the computation and communication needs during online emergency responses, thus preventing the cascading propagation of contingencies for enhanced power grid resilience. Numerical studies on both the IEEE 118-bus system and a synthetic Texas 2000-bus system have demonstrated the efficiency and effectiveness of our scalable OLS learning design for timely power system emergency operations.
A NASA sponsored study of space power distribution system technology is in progress to develop an autonomously managed power system (AMPS) for large space power platforms. The multichannel, multikilowatt, utility-type power subsystem proposed presents new survivability requirements and increased subsystem complexity. The computer controls under development for the power management system must optimize the power subsystem performance and minimize the life cycle cost of the platform. A distribution system management philosophy has been formulated which incorporates these constraints. Its implementation using a TI9900 microprocessor and FORTH as the programming language is presented. The approach offers a novel solution to the perplexing problem of determining the optimal combination of loads which should be connected to each power channel for a versatile electrical distribution concept.
This paper summarizes a grid optimization (GO) competition effort in the United States to find the best solution strategies for up to interconnect-scale power system networks with around 32,000 buses. The optimization problem is a mixedinteger, non-convex non-linear problem, (MINLP) and includes discrete variables such as unit commitment and line switching, control settings (transformer taps and phase shifters with impedance correction tables), and bus shunts. The case study includes six actual industry grids as well as 16 realistic synthetic grids created by three different dataset teams. The winners are selected and ranked based on scoring criteria, which consider the solution quality (such as objective functions) within time limits. Nine winner teams are selected from 26 competitor teams. The results achieved by different teams are described and the performance of different algorithms on synthetic grids and actual industry grids are compared and analyzed.