Search NASA⌕ Search

SEARCH · Search NASA

Results for “progressive precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Experimental Design for the LATOR Mission

This paper discusses experimental design for the Laser Astrometric Test Of Relativity (LATOR) mission. LATOR is designed to reach unprecedented accuracy of 1 part in 10(exp 8) in measuring the curvature of the solar gravitational field as given by the value of the key Eddington post-Newtonian parameter gamma. This mission will demonstrate the accuracy needed to measure effects of the next post-Newtonian order (near infinity G2) of light deflection resulting from gravity s intrinsic non-linearity. LATOR will provide the first precise measurement of the solar quadrupole moment parameter, J(sub 2), and will improve determination of a variety of relativistic effects including Lense-Thirring precession. The mission will benefit from the recent progress in the optical communication technologies the immediate and natural step above the standard radio-metric techniques. The key element of LATOR is a geometric redundancy provided by the laser ranging and long-baseline optical interferometry. We discuss the mission and optical designs, as well as the expected performance of this proposed mission. LATOR will lead to very robust advances in the tests of Fundamental physics: this mission could discover a violation or extension of general relativity, or reveal the presence of an additional long range interaction in the physical law. There are no analogs to the LATOR experiment; it is unique and is a natural culmination of solar system gravity experiments.

Turyshev, Slava G.↗

Lynx X-Ray Microcalorimeter Cryogenic System

The Lynx x-ray microcalorimeter instrument on the Lynx X-ray Observatory requires a state-of-the-art cryogenic system to enable high-precision and high-resolution x-ray spectroscopy. The cryogenic system and components described provide the required environment using cooling technologies that are already at relatively high technology readiness levels and are progressing toward flight-compatible subsystems. These subsystems comprise a cryostat, a 4.5-K mechanical cryocooler, and an adiabatic demagnetization refrigerator that provides substantial cooling power at 50 mK.

DiPirro, Michael↗

Novel Signatures Beyond the Standard Model: From Extreme Environments to Precision Measurements

Most of our universe is dark. It is dark literally—visible matter makes up only 5% of the energy density—and conceptually, as many outstanding questions remain unsolved. The discovery of particle dark matter would shed light on our dark universe and throw open a window on the highest energy scales. This research made progress toward dark matter and new particle searches in three ways. Extreme compact objects, such as black holes, neutron stars, and stellar cores, can parametrically increase the production rates of feebly interacting particles and yield observable signatures. Specifically, a process known as superradiance leads to exponential growth of the number of ultralight particles gravitationally bound to rotating black holes, and turns astrophysical black holes into particle detectors. This research broadened the scope of applicability of superradiance studies to particles with a wide range of interactions and masses, predicting multi messenger signals. When ultralight particles are produced as dark matter in the early universe, they can be detected directly in laboratory experiments. However, these feebly interacting particles lead to small signals that are inevitably difficult to tease out from backgrounds; their detection requires the theoretical development of unique signatures that can be searched for in low-noise experiments. Some dark matter particles could be detectable with thin film metamaterials combined with low noise single-photon detectors. This research develop the theoretical framework and supported experimental efforts for ambitious searches for a wider class of ultralight particles. Overall, the outcome of this theoretical particle physics program developed novel signatures of new dark matter particles, and thereby expanded the particle parameter space which can be explored with astrophysical observations and precision experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

What can we learn from N 2 O isotope data? – Analytics, processes and modelling

The isotopic composition of nitrous oxide (N 2 O) provides useful information for evaluating N 2 O sources and budgets. Due to the co–occurrence of multiple N 2 O transformation pathways, it is, however, challenging to use isotopic information to quantify the contribution of distinct processes across variable spatiotemporal scales. Here, we present an overview of recent progress in N 2 O isotopic studies and provide suggestions for future research, mainly focusing on: analytical techniques; production and consumption processes; and interpretation and modelling approaches. Comparing isotope–ratio mass spectrometry (IRMS) with laser absorption spectroscopy (LAS), we conclude that IRMS is a precise technique for laboratory analysis of N 2 O isotopes, while LAS is more suitable for in situ/inline studies and offers advantages for site–specific analyses. When reviewing the link between the N 2 O isotopic composition and underlying mechanisms/processes, we find that, at the molecular scale, the specific enzymes and mechanisms involved determine isotopic fractionation effects. In contrast, at plot–to–global scales, mixing of N 2 O derived from different processes and their isotopic variability must be considered. We also find that dual isotope plots are effective for semi–quantitative attribution of co–occurring N 2 O production and reduction processes. More recently, process–based N 2 O isotopic models have been developed for natural abundance and 15 N–tracing studies, and have been shown to be effective, particularly for data with adequate temporal resolution. Here, despite the significant progress made over the last decade, there is still great need and potential for future work, including development of analytical techniques, reference materials and inter–laboratory comparisons, further exploration of N 2 O formation and destruction mechanisms, more observations across scales, and design and validation of interpretation and modelling approaches. Synthesizing all these efforts, we are confident that the N 2 O isotope community will continue to advance our understanding of N 2 O transformation processes in all spheres of the Earth, and in turn to gain improved constraints on regional and global budgets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SIM-PlanetQuest: Progress Report

SIM-PlanetQuest is a NASA astrophysics mission that is implementing the National Research Counsel's recommended Astrometric Interferometry Mission (AIM) to develop the first, in-space, optical, long-baseline Michelson Stellar Interferometer for performing micro-arcsecond-level astrometry. This level of astrometric precision will enable characterization of planetary systems around nearby stars and enable a number of key investigations in astrophysics including calibration of the cosmological distance scale, stellar and galactic structure and evolution, and dark matter/energy distribution. This paper provides an update on the SIM-PlanetQuest Mission covering the results of the 2005 mission redesign and the recent completion of the last in a series of technology "gates." The SIM-PlanetQuest mission redesign was directed by NASA to recover eroded mass and power margins and to meet specific implementation cost targets. The resulting mission redesign met all redesign objectives with minimal impact to mission science performance. This paper provides the mission redesign objectives and describes the resulting mission and system design including changes in science capability. SIM-PlanetQuest also completed the last of eight major technology development gates that were established in 2001 by NASA, completing the enabling technology development. The technology development program, the last gate, and its significance to the project's flight verification and validation (V&V) approach are briefly described (covered in more detail in a separate paper at this conference). An update on project programmatic status and plans is also provided.

astrometry↗

FRET-based dynamic structural biology: Challenges, perspectives and an appeal for open-science practices

Single-molecule FRET (smFRET) has become a mainstream technique for studying biomolecular structural dynamics. The rapid and wide adoption of smFRET experiments by an ever-increasing number of groups has generated significant progress in sample preparation, measurement procedures, data analysis, algorithms and documentation. Several labs that employ smFRET approaches have joined forces to inform the smFRET community about streamlining how to perform experiments and analyze results for obtaining quantitative information on biomolecular structure and dynamics. The recent efforts include blind tests to assess the accuracy and the precision of smFRET experiments among different labs using various procedures. These multi-lab studies have led to the development of smFRET procedures and documentation, which are important when submitting entries into the archiving system for integrative structure models, PDB-Dev. This position paper describes the current ‘state of the art’ from different perspectives, points to unresolved methodological issues for quantitative structural studies, provides a set of ‘soft recommendations’ about which an emerging consensus exists, and lists openly available resources for newcomers and seasoned practitioners. To make further progress, we strongly encourage ‘open science’ practices.

59 BASIC BIOLOGICAL SCIENCES↗

Double-pulse speckle contrast correlations with near Fourier transform limited free-electron laser light using hard X-ray split-and-delay

Abstract The ability to deliver two coherent X-ray pulses with precise time-delays ranging from a few femtoseconds to nanoseconds enables critical capabilities of probing ultra-fast phenomena in condensed matter systems at X-ray free electron laser (FEL) sources. Recent progress made in the hard X-ray split-and-delay optics developments now brings a very promising prospect for resolving atomic-scale motions that were not accessible by previous time-resolved techniques. Here, we report on characterizing the spatial and temporal coherence properties of the hard X-ray FEL beam after propagating through split-and-delay optics. Speckle contrast analysis of small-angle scattering measurements from nanoparticles reveals well-preserved transverse coherence of the beam. Measuring intensity fluctuations from successive X-ray pulses also reveals that only single or double temporal modes remain in the transmitted beam, corresponding to nearly Fourier transform limited pulses.

42 ENGINEERING↗

Atomic/molecular layer deposition for energy storage and conversion

Energy storage and conversion systems, including batteries, supercapacitors, fuel cells, solar cells, and photoelectrochemical water splitting, have played vital roles in the reduction of fossil fuel usage, addressing environmental issues and the development of electric vehicles. The fabrication and surface/interface engineering of electrode materials with refined structures are indispensable for achieving optimal performances for the different energy-related devices. Atomic layer deposition (ALD) and molecular layer deposition (MLD) techniques, the gas-phase thin film deposition processes with self-limiting and saturated surface reactions, have emerged as powerful techniques for surface and interface engineering in energy-related devices due to their exceptional capability of precise thickness control, excellent uniformity and conformity, tunable composition and relatively low deposition temperature. In the past few decades, ALD and MLD have been intensively studied for energy storage and conversion applications with remarkable progress. In this work, we give a comprehensive summary of the development and achievements of ALD and MLD and their applications for energy storage and conversion, including batteries, supercapacitors, fuel cells, solar cells, and photoelectrochemical water splitting. Moreover, the fundamental understanding of the mechanisms involved in different devices will be deeply reviewed. Furthermore, the large-scale potential of ALD and MLD techniques is discussed and predicted. Finally, we will provide insightful perspectives on future directions for new material design by ALD and MLD and untapped opportunities in energy storage and conversion.

25 ENERGY STORAGE↗

Time-domain terahertz emission spectroscopy on van der Waals materials

Time-domain terahertz (THz) emission spectroscopy provides a direct method to probe transient photo-currents by recording the emitted terahertz electric field. Although the basic principles of THz surface emission have been understood for more than 30 years, the constant progress in ultrafast laser science to ever shorter pulses, the development of new materials and enhanced sensitivity promote THz emission spectroscopy as a reliable method to gain insights into charge carrier dynamics with unprecedented precision. It provides a versatile tool to study ultrafast processes, such as plasmon-driven hot carriers, dynamics of Dirac fermions, interfacial charge transfer, coherent phonon emission and quantum beating, to name only a few. However, despite the rapidly growing body of research on van der Waals materials, especially in their low-dimensional limit, THz emission spectroscopy has only been applied to a limited extent in these material systems. In this prospective, we review time-domain THz emission spectroscopy as a complementary approach to probe ultrafast charge carrier dynamics and the material’s nonlinear response. After a description of the experimental method, we report on THz emission spectroscopy of bulk and 2D van der Waals materials with special focus on graphene and transition metal dichalcogenide layers.

2D materials↗

Development of an integrated BEM approach for hot fluid structure interaction

In the present work, the boundary element method (BEM) is chosen as the basic analysis tool, principally because the definition of temperature, flux, displacement and traction are very precise on a boundary-based discretization scheme. One fundamental difficulty is, of course, that a BEM formulation requires a considerable amount of analytical work, which is not needed in the other numerical methods. Progress made toward the development of a boundary element formulation for the study of hot fluid-structure interaction in Earth-to-Orbit engine hot section components is reported. The primary thrust of the program to date has been directed quite naturally toward the examination of fluid flow, since boundary element methods for fluids are at a much less developed state.

Dargush, Gary F.↗

Flight Test Evaluation of Autonomous Descending-Decelerating Precision Point-in-Space Approach to the Ground

New forms of highly automated Advanced Air Mobility (AAM) aircraft, such as electric vertical take-off and landing (eVTOL) vehicles, could transform transportation, cargo delivery, and a variety of public services. The National Aeronautics and Space Administration (NASA) conducted a series of flight demonstrations in collaboration with the Defense Advanced Research Projects Agency (DARPA) and Sikorsky Aircraft (a Lockheed Martin company) to progressively evaluate autonomous technologies. The autoland flight test research is a first in series for investigating the world’s first procedural descending-decelerating automated landing with vertical guidance Instrument Flight Procedures (IFP). The Sikorsky Optionally Piloted Vehicle (OPV) experimental UH-60 Black Hawk was used to evaluate a flight path’s four-dimensional trajectory (4DT) management into primitive commands and then follow those commands to a Point-in-Space (PinS) landing to the ground. All flight procedures were manually flown to the ground at 12 degrees with a 20-knot tail wind to ensure flight safety before automation was engaged. New and novel high precision approach procedures could pave the way for all future VTOL operations.

David Zahn↗

The Space Interferometry Mission (SIM): technology development progress and plans

Optical and infrared interferometry will open new vistas for astronomy over the next decade. Space based interferometers, operating unfettered by the Earth's atmosphere, will offer the greatest scientific payoff. They also present the greatest technological challenge: laser metrology systems must perform with sub-nanometer precision; mechanical vibrations must be controlled to nanometers requiring orders of magnitude distrubance rejection; a multitude of actuators and sensors must operate flawlessly and in concert.

interferometry metrology pointing control nanomete↗

Thermo-structural design of the European DEMO water-cooled blanket with a multiscale-multiphysics framework

The Water-Cooled Lithium-Lead (WCLL) blanket concept is one of four possible embodiments under consideration for the European Demonstration Power Plant DEMO, beyond ITER. It is based on a water-cooled first wall and blanket structure with the RAFMS (Reduced Activation Ferritic/Martensitic Steel, Eurofer 97) as structural material and PbLi as neutron multiplier and tritium breeder. We first develop a multiphysics modeling framework in order to optimize the design and achieve long blanket lifetime, maintainability, and high reliability. The approach is demonstrated by coupling Computational Fluid Dynamics (CFD), heat transfer and solid mechanics. The multiphysics framework is then utilized to provide the loading conditions for a multiscale design approach particularly focused on modeling the effects of both steady-state and operational transients on the structural integrity of the First Wall (FW). The methodology builds on the ITER Structural Design Criteria for In-Vessel Components (ISDC-IC), then extending the criteria to progressively incorporate continuum plasticity models and microstructure-based representation of deformation and fracture. We finally introduce advanced fracture mechanics concepts based on a Materials-Specific Failure Assessment Diagram (MS-FAD), in which precise calculations of the J-integral of an elasto-plastic material is required. This is especially important for the water-cooled design because of the limited fracture toughness of Eurofer 97 below 300 °C. The methodology has been applied to screen the FW/Blanket performance of a range of steady state heat flux assumed to be applied during the plasma pulse flat top, and up to 0.8 MW/m 2 . It has become clear that the radiation steady state load will be lower than the values screened here, while the local heat flux due to particle loads will lead to global higher values than the values investigated here. The methodology will be further fine-tuned to specific loading conditions in order to assess actual performance limits of the DEMO WCLL BB.

European DEMO↗

WE-G-BRD-02: Characterizing Information Loss in a Sparse-Sampling-Based Dynamic MRI Sequence (k-T BLAST) for Lung Motion Monitoring

Purpose: Rapid MRI is an attractive, non-ionizing tool for soft-tissue-based monitoring of respiratory motion in thoracic and abdominal radiotherapy. One big challenge is to achieve high temporal resolution while maintaining adequate spatial resolution. K-t BLAST, sparse-sampling and reconstruction sequence based on a-priori information represents a potential solution. In this work, we investigated how much “true” motion information is lost as a-priori information is progressively added for faster imaging. Methods: Lung tumor motions in superior-inferior direction obtained from ten individuals were replayed into an in-house, MRI-compatible, programmable motion platform (50Hz refresh and 100microns precision). Six water-filled 1.5ml tubes were placed on it as fiducial markers. Dynamic marker motion within a coronal slice (FOV: 32×32cm{sup 2}, resolution: 0.67×0.67mm{sup 2}, slice-thickness: 5mm) was collected on 3.0T body scanner (Ingenia, Philips). Balanced-FFE (TE/TR: 1.3ms/2.5ms, flip-angle: 40degrees) was used in conjunction with k-t BLAST. Each motion was repeated four times as four k-t acceleration factors 1, 2, 5, and 16 (corresponding frame rates were 2.5, 4.7, 9.8, and 19.1Hz, respectively) were compared. For each image set, one average motion trajectory was computed from six marker displacements. Root mean square error (RMS) was used as a metric of spatial accuracy where measured trajectories were compared to original data. Results: Tumor motion was approximately 10mm. The mean(standard deviation) of respiratory rates over ten patients was 0.28(0.06)Hz. Cumulative distributions of tumor motion frequency spectra (0–25Hz) obtained from the patients showed that 90% of motion fell on 3.88Hz or less. Therefore, the frame rate must be a double or higher for accurate monitoring. The RMS errors over patients for k-t factors of 1, 2, 5, and 16 were.10(.04),.17(.04), .21(.06) and.26(.06)mm, respectively. Conclusions: K-t factor of 5 or higher can cover the high frequency component of tumor respiratory motion, while the estimated error of spatial accuracy was approximately.2mm.

60 APPLIED LIFE SCIENCES↗

The constraint method: A new finite element technique

An approch to the finite element method which utilizes families of conforming finite elements based on complete polynomials is presented. Finite element approximations based on this method converge with respect to progressively reduced element sizes as well as with respect to progressively increasing orders of approximation. Numerical results of static and dynamic applications of plates are presented to demonstrate the efficiency of the method. Comparisons are made with plate elements in NASTRAN and the high-precision plate element developed by Cowper and his co-workers. Some considerations are given to implementation of the constraint method into general purpose computer programs such as NASTRAN.

Tsai, C.↗

Scientific Data Analysis and Software Support: Geodynamics

The support on this contract centers on development of data analysis strategies, geodynamic models, and software codes to study four-dimensional geodynamic and oceanographic processes, as well as studies and mission support for near-Earth and interplanetary satellite missions. SRE had a subcontract to maintain the optical laboratory for the LTP, where instruments such as MOLA and GLAS are developed. NVI performed work on a Raytheon laser altimetry task through a subcontract, providing data analysis and final data production for distribution to users. HBG had a subcontract for specialized digital topography analysis and map generation. Over the course of this contract, Raytheon ITSS staff have supported over 60 individual tasks. Some tasks have remained in place during this entire interval whereas others have been completed and were of shorter duration. Over the course of events, task numbers were changed to reflect changes in the character of the work or new funding sources. The description presented below will detail the technical accomplishments that have been achieved according to their science and technology areas. What will be shown is a brief overview of the progress that has been made in each of these investigative and software development areas. Raytheon ITSS staff members have received many awards for their work on this contract, including GSFC Group Achievement Awards for TOPEX Precision Orbit Determination and the Joint Gravity Model One Team. NASA JPL gave the TOPEX/POSEIDON team a medal commemorating the completion of the primary mission and a Certificate of Appreciation. Raytheon ITSS has also received a Certificate of Appreciation from GSFC for its extensive support of the Shuttle Laser Altimeter Experiment.

Klosko, Steven↗

Atomic Layer Deposition Josephson Junctions for Cryogenic Circuit Applications

Superconducting-insulating-superconducting (SIS) trilayers have been produced for Josephson Junction fabrication by thermal atomic layer deposition (ALD) processes. The trilayers are composed of alternating layers of Ti0.4N0.6/Al2O3/ Ti0.4N0.6, deposited at 450°C, in a thermal ALD reactor on Al2O3-coated silicon. The conformal nature of the ALD process provides excellent step coverage of superconducting and insulating films. The film thickness of a single ALD cycle being one mono-layer, allows us to precisely control the tunnel-barrier insulator thickness by counting the number of ALD cycles during the insulator deposition step. Tunnel-junctions with critical current 500 A/cm2 are reported. Fabrication of Josephson Junctions and progress toward development of a single-element ALD Superconducting Quantum Interference Device (SQUID) will be discussed

Atomic Layer Definition↗

Integrated frequency-modulated optical parametric oscillator

Optical frequency combs have revolutionized precision measurement, time-keeping, and molecular spectroscopy. A substantial effort has developed around "microcombs": integrating comb-generating technologies into compact, reliable photonic platforms. Current approaches for generating these microcombs involve either the electro-optic (EO) or Kerr mechanisms. Despite rapid progress, maintaining high efficiency and wide bandwidth remains challenging. Here, we introduce a new class of microcomb -- an integrated optical frequency comb generator that combines electro-optics and parametric amplification to yield a frequency-modulated optical parametric oscillator (FM-OPO). In stark contrast to EO and Kerr combs, the FM-OPO microcomb does not form pulses but maintains operational simplicity and highly efficient pump power utilization with an output resembling a frequency-modulated laser. We outline the working principles of FM-OPO and demonstrate them by fabricating the complete optical system in thin-film lithium niobate (LNOI). We measure pump to comb internal conversion efficiency exceeding 93% (34% out-coupled) over a nearly flat-top spectral distribution spanning approximately 1,000 modes (approximately 6 THz). Compared to an EO comb, the cavity dispersion rather than loss determines the FM-OPO bandwidth, enabling broadband combs with a smaller RF modulation power. The FM-OPO microcomb, with its robust operational dynamics, high efficiency, and large bandwidth, contributes a new approach to the field of microcombs and promises to herald an era of miniaturized precision measurement, and spectroscopy tools to accelerate advancements in metrology, spectroscopy, telecommunications, sensing, and computing.

42 ENGINEERING↗