Search NASA⌕ Search

SEARCH · Search NASA

Results for “prototype specifications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Coupled SAM/Griffin Model of a Reference Fluoride-Salt-Cooled High-Temperature Reactor for Multi-Physics Simulations

A multi-physics coupled simulation model of a reference pebble bed fluoride-salt-cooled high-temperature reactor (PB-FHR) has been developed with SAM and Griffin computer codes for transient safety analysis. The reference problem of a prototypical reactor design serves as the foundation for the U.S. NRC (Nuclear Regulatory Commission) to verify the adequacy of computer codes and evaluation models for specific reactor types. In this work, the previously developed SAM model for PB-FHR primary loop has been updated for the coupled simulation. The updated SAM PB-FHR model includes a 2-D axial symmetric core region and external core components in 0-D/1-D. In addition to the primary loop, a detailed model of the RCCS (reactor cavity cooling system) is added. The 2-D and 1-D domains are tightly coupled using the single-solve approach developed in SAM. In the pebble bed region, the SAM multiscale explicit pebble model is applied to calculate the pebble and TRISO fuel kernel temperatures. The Griffin model used in this work is based on a model developed at Idaho National Laboratory in collaboration with the U.S. NRC. The Griffin neutronics model and SAM thermal hydraulics model is coupled with the Comprehensive Reactor Analysis Bundle (CRAB or alternately BlueCRAB) application. Both steady-state and transient scenarios are simulated to demonstrate the model's suitability for multi-physics simulations of PB-FHR transients.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Distributed Resilience in High-Energy Physics Data Acquisition

Historical experience in the High-Performance Computing community teaches us that as computing systems grow, the instance of failures goes from rare to a regular occurrence. A survey of the growth in the size and complexity of Data AcQuisition (DAQ) networks in High-Energy Physics (HEP) experiments reveals that these networks are scaling exponentially, trending to a point where automated fault handling should be considered over the current manual practice, especially given the rarity of data such as in DUNE's mission to observe core-collapse supernovae. We propose a general system, DiDAQt, which is designed to provide fault detection and handling in HEP DAQs specifically, through MPI-like primitives that allow it to be added easily to existing systems. We evaluate the scalability and response time of a prototype on the FABRIC national testbed, with results indicating sufficient scalability for current and near-future DAQs as well as practical response times (under 1 microsecond decision time).

Wolosewicz, A. [IIT, Chicago]↗

Advancing the HERO WEC Through Integrated Modeling, Testing, and Field Deployments

The Hydraulic and Electric Reverse Osmosis Wave Energy Converter (HERO WEC) was developed by the National Laboratory of the Rockies as a modular platform for advancing wave-powered desalination technologies. Designed to operate in either a hydraulic or electric configuration, the system enables direct comparison of mechanical-to-water and electrical-to-water conversion pathways using a single hardware architecture. Deployments in 2022 and 2024 at the Jennette's Pier test site in North Carolina demonstrated freshwater production between 60 and 300 gallons per day, including successful operation in wave heights as low as 0.25 m. A structured evaluation approach combining numerical modeling of hydrodynamic and power take-off response, controlled laboratory testing, and in-ocean field deployments has been used to characterize and refine system performance. Specifically, insights from these efforts are now informing the second-generation HERO WEC (V2) to increase robustness and overall survivability. Changes from the original prototype include improved drivetrain components, refined geometry, enhanced control systems, and design. The HERO WEC platform continues to serve as an open-access research asset supporting broader marine energy and desalination development.

16 TIDAL AND WAVE POWER↗

Fabrication Technologies of the High Gradient Accelerator Structures at 100MV/M Range

A CERN-SLAC-KEK collaboration on high gradient X-band structure research has been established in order to demonstrate the feasibility of the CLIC baseline design for the main linac stably operating at more than 100 MV/m loaded accelerating gradient. Several prototype CLIC structures were successfully fabricated and high power tested. They operated at 105 MV/m with a breakdown rate that meets the CLIC linear collider specifications of < 5 x 10{sup -7}/pulse/m. This paper summarizes the fabrication technologies including the mechanical design, precision machining, chemical cleaning, diffusion bonding as well as vacuum baking and all related assembly technologies. Also, the tolerances control, tuning and RF characterization will be discussed.

43 PARTICLE ACCELERATORS↗

SMART-COM – Scalable Multi-Agent Adaptive Resolution Tools for Collaborative Outage Management

The purpose of this grant was to conduct scientific research and prototype applications to support NPP outage staff in their adaptive decision-making in efficient scheduling and resource allocation while preventing violation of safety technical specifications. The project contributed to scientific knowledge and engineering methods in (1) user interface design, (2) scheduling optimization and risk estimation, and (2) natural language processing that would benefit the nuclear power plants in minimizing schedule overruns and even unexpected shutdowns. The research team conducted site visits at a test reactor facility and an operating nuclear power plant to gather necessary information and inputs for research and development of a software application to support NPP staff in executing their outages. The final software application consisted of three modules. First, the natural language processing module supports interactive processing of technical documentation to build a database for outage staff to query non-permissible actions on system components. This module can alleviate outage staff from reviewing extensive documentation and minimize violation of technical specifications, especially in time-sensitive situations. Second, the schedule optimization module schedules outage activities and compute risk indices that outperform existing software and current practice. This module can reduce completion time of an outage that typically have too many activities for human to optimize based on current practice that does not apply the latest operations research. Finally, the visualization module presents progress and risk information of the overall outage and individual activities, as well as enabling access to the natural language processing and schedule optimization modules. This module can provide outage staff with situation awareness that are necessary to make risk-informed decisions in response to unexpected events during the execution of an outage.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The CWS Experiments – An Experimental Study of the Effects of Chlorine on Thermal Neutron Absorption

The Chlorine Worth Study (CWS) experiments consist of layers of Zero Power Physics Reactor plates moderated by high density polyethylene, polyvinyl chloride, and chlorinated polyvinyl chloride with the goal to produce a thermal critical experiment. A thick high density polyethylene reflector surrounds the experiments. Aluminum fuel trays and frames were used to conduct the intrinsic heat generation of the plutonium plates away from the core and out to the top plate and the platen, both acting as heat sinks. The goal of the CWS experiments was to provide benchmark critical experiments that were sensitive to chlorine and matched the sensitivity of criticality safety applications for aqueous chloride operations at PF-4 at Los Alamos National Laboratory. The specific aqueous chloride PF-4 applications were solutions of 30 g/L plutonium, 300 g/L plutonium, and 600 g/L plutonium. The CWS experiments were designed using prototype methods developed by the ARCHIMEDES and EUCLID projects at Los Alamos National Laboratory. The CWS experiments were performed in December of 2021 at the National Criticality Experiments Research Center at the Nevada Nuclear Security Site on the Planet critical assembly. It is intended that the CWS experiments will be evaluated and submitted to the ICSBEP in the future as criticality safety benchmarks.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Monte-Carlo Simulations of the Nuclear Energy Deposition Inside the CARMEN-1P Differential Calorimeter Irradiated into OSIRIS Reactor

The nuclear heating measurements in Material Testing Reactors (MTRs) are crucial for the study of nuclear materials and fuels under irradiation. The reference measurements of this nuclear heating are especially performed by a differential calorimeter including a graphite sample material. These measurements are then used for other experimental conditions in order to predict the nuclear heating and thermal conditions induced in the irradiation devices. Nuclear heating is a great deal of interest at the moment as the measurement of such heating is an important issue for MTRs reactors. This need is especially generated by the new Jules Horowitz Reactor (JHR), under construction at CEA/Cadarache 'French Alternative Energies and Atomic Energy Commission'. This new reactor, that will be operational in late 2019, is a new facility for the nuclear research on materials and fuels. Indeed the expected nuclear heating rate is about 20 W/g for nominal capacity of 100 MW. The present Monte Carlo calculation works belong to the IN-CORE (Instrumentation for Nuclear radiation and Calorimetry On line in Reactor): a joint research program between the CEA and Aix- Marseille University in 2009. One scientific aim of this program is to design and develop a multi-sensors device, called CARMEN, dedicated to the measurements of main physical parameters simultaneously encountered inside JHR's experimental channels (core and reflector) such as neutron fluxes, photon fluxes, temperature, and nuclear heating. A first prototype was already developed. This prototype includes two mock-ups dedicated respectively to neutronic measurements (CARMEN-1N) and to photonic measurements (CARMEN-1P) with in particular a specific differential calorimeter. Two irradiation campaigns were performed successfully in the periphery of OSIRIS reactor (a MTR located at Saclay, France) in 2012 for nuclear heating levels up to 2 W/g. First Monte Carlo calculations reduced to the graphite sample of the calorimeter were carried out. A preliminary analysis shows that the numerical results overestimate the measurements by about 20 %. A new approach has been developed in order to estimate the nuclear heating by two methods (energy deposition or KERMA) by considering the whole complete geometry of the sensor. This new approach will contribute to the interpretation of the irradiation campaign and will be useful to improve the out-of-pile calibration procedure of the sensor and its thermal response during irradiations. The aim of this paper is to present simulations made by using MCNP5 Monte-Carlo transport code (using ENDF/B-VI nuclear data library) for the nuclear heating inside the different parts of the calorimeter (head, rod and base). Calculations into two steps will be realized. We will use as an input source in the model new spectra (neutrons, prompt-photons and delayed-photons) calculated with the Monte Carlo code TRIPOLI-4{sup R} inside different experimental channels (water) located into the OSIRIS periphery and used during the CARMEN-1P irradiation campaign. We will consider Neutrons- Photons-Electrons and Photons-Electrons modes. We will begin by a brief description of the differential-calorimeter device geometry. Then the MCNP5 model used for the calculations of nuclear heating inside the calorimeter elements will be introduced. The energy deposition due to the prompt-gamma, delayed-gamma and neutrons, the neutron-activation of the device will be considered. The different components of the nuclear heating inside the different parts of the calorimeter will be detailed. Moreover, a comparison between KERMA and nuclear energy deposition estimations will be given. Finally, a comparison between this total nuclear heating Calculation and Experiment in graphite sample will be determined. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A New Safeguards Technique for Spent Fuel Verification in Dry Storage by Using He-4 Detectors - 18262

It is demanded to find key issues and critical paths for verifying and monitoring a spent nuclear fuel cask or storage with a purpose of non-proliferation of nuclear weapon. However, unfortunately there are no reliable methods to verify the containment in a spent nuclear fuel cask or storage. Therefore, research and development (R and D) has been continuously required to develop new and alternative technologies for searching and verifying undeclared nuclear materials, activities, and facilities. Therefore, the present authors have developed a new safeguards technique of passively scanning a spent fuel cask or storage using pressurized He-4 scintillation neutron detectors. A new approach is to quickly verify content in a spent nuclear fuel cask or presence of all special nuclear materials in unknown packages by comparing experimental and computational results. For that, the present authors have developed a new algorithm and user-interface coupled ORIGEN-ARP and MCNP codes, and the prototype safeguards apparatus employing the array of He-4 fast neutron detectors has been designed, built, and tested. The feasibility test of this new apparatus has been performed with Cf-252 neutron sources and the laboratory scale model cask, minimized by a factor of ten compared to the actual dimension of a KN-21 cask. This technique has several advantages over current methods based on neutron and gamma detection; (1) incident neutron energy information is preserved, (2) disturbance of gamma-ray is excellently rejected (discriminated), and (3) much higher neutron counts and operational cost and space-effectiveness are expected since no moderator is required for fast neutrons. The final goal of this study will (1) conduct a prototype instrument and employ it to monitor a nuclear spent fuel cask or storage at a commercial nuclear power reactor facilities, (2) use spectral-specific measurement data to show proof of concept for measurable data successfully converted to quantifiable signatures, such as diversion/removal of fuel, and maintenance of fuel and cask integrity of fuel, and (3) develop a cask imaging capability. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characteristic performance evaluation of a photon counting Si strip detector for low dose spectral breast CT imaging

Purpose: The possible clinical applications which can be performed using a newly developed detector depend on the detector's characteristic performance in a number of metrics including the dynamic range, resolution, uniformity, and stability. The authors have evaluated a prototype energy resolved fast photon counting x-ray detector based on a silicon (Si) strip sensor used in an edge-on geometry with an application specific integrated circuit to record the number of x-rays and their energies at high flux and fast frame rates. The investigated detector was integrated with a dedicated breast spectral computed tomography (CT) system to make use of the detector's high spatial and energy resolution and low noise performance under conditions suitable for clinical breast imaging. The aim of this article is to investigate the intrinsic characteristics of the detector, in terms of maximum output count rate, spatial and energy resolution, and noise performance of the imaging system. Methods: The maximum output count rate was obtained with a 50 W x-ray tube with a maximum continuous output of 50 kVp at 1.0 mA. A{sup 109}Cd source, with a characteristic x-ray peak at 22 keV from Ag, was used to measure the energy resolution of the detector. The axial plane modulation transfer function (MTF) was measured using a 67 μm diameter tungsten wire. The two-dimensional (2D) noise power spectrum (NPS) was measured using flat field images and noise equivalent quanta (NEQ) were calculated using the MTF and NPS results. The image quality parameters were studied as a function of various radiation doses and reconstruction filters. The one-dimensional (1D) NPS was used to investigate the effect of electronic noise elimination by varying the minimum energy threshold. Results: A maximum output count rate of 100 million counts per second per square millimeter (cps/mm{sup 2}) has been obtained (1 million cps per 100 × 100 μm pixel). The electrical noise floor was less than 4 keV. The energy resolution measured with the 22 keV photons from a {sup 109}Cd source was less than 9%. A reduction of image noise was shown in all the spatial frequencies in 1D NPS as a result of the elimination of the electronic noise. The spatial resolution was measured just above 5 line pairs per mm (lp/mm) where 10% of MTF corresponded to 5.4 mm{sup −1}. The 2D NPS and NEQ shows a low noise floor and a linear dependence on dose. The reconstruction filter choice affected both of the MTF and NPS results, but had a weak effect on the NEQ. Conclusions: The prototype energy resolved photon counting Si strip detector can offer superior imaging performance for dedicated breast CT as compared to a conventional energy-integrating detector due to its high output count rate, high spatial and energy resolution, and low noise characteristics, which are essential characteristics for spectral breast CT imaging.

60 APPLIED LIFE SCIENCES↗

Design of high-performance guns for the HL-LHC HEL

The High Luminosity LHC project (HL-LHC) foresees the construction and installation of important new equipment to increase the performance of the LHC machine. The Hollow Electron Lens (HEL) is a promising system to control the beam halo. It improves the beam collimation system of the HL-LHC and mitigates possible equipment damage in case of failure scenarios from halo losses. The halo can store up to 30 MJ energy. The specifications for this new device are quite demanding. The source, an electron gun with an annular shaped cathode, must deliver a current up to 5 A. Additionally, this is five times higher than the current in the existing electron lenses in Fermi and Brookhaven national laboratories. This note describes the programme carried out to design and test high-perveance guns equipped with two types of high-performance scandate cathodes. The size of the final gun for the HL-LHC lenses is now considerably smaller than the one of the first prototype, allowing a reduction of diameter and cost of the superconducting magnet system used to steer the electron beam. The tests carried out at FNAL, BVERI and BJUT demonstrated that the developed cathodes fulfil the specifications and can supply a 5 A fully Space Charge Limited (SCL) current.

43 PARTICLE ACCELERATORS↗

Consequences of CCD imperfections for cosmology determined by weak lensing surveys: from laboratory measurements to cosmological parameter bias

Weak gravitational lensing causes subtle changes in the apparent shapes of galaxies due to the bending of light by the gravity of foreground masses. By measuring the shapes of large numbers of galaxies (millions in recent surveys, up to tens of billions in future surveys) we can infer the parameters that determine cosmology. Imperfections in the detectors used to record images of the sky can introduce changes in the apparent shapes of galaxies, which in turn can bias the inferred cosmological parameters. In this paper we consider the effect of two widely discussed sensor imperfections: tree rings, due to impurity gradients that cause transverse electric fields in the charge-coupled devices (CCDs), and pixel size variation, due to periodic CCD fabrication errors. These imperfections can be observed when the detectors are subject to uniform illumination (flat-field images). We develop methods to determine the spurious shear and convergence (due to the imperfections) from the flat-field images. We calculate how the spurious shear when added to the lensing shear will bias the determination of cosmological parameters. We apply our methods to candidate sensors of the Large Synoptic Survey Telescope (LSST) as a timely and important example, analyzing flat-field images recorded with LSST prototype CCDs in the laboratory. We find that tree rings and periodic pixel size variation present in the LSST CCDs will introduce negligible bias to cosmological parameters determined from the lensing power spectrum, specifically w, Ω{sub m}, and σ{sub 8}.

79 ASTRONOMY AND ASTROPHYSICS↗

Inspecta Technical Report

Sandia National Laboratories (SNL) is in the process of creating Inspecta (International Nuclear Safeguards Personal Examination and Containment Tracking Assistant), an Artificial Intelligence (AI)-powered smart digital assistant (SDA) with robotic capabilities, aimed at enhancing the effectiveness, efficiency, and safety of international nuclear safeguards inspections. This innovative tool is designed to assist inspectors on-site by supporting or automating tasks that are typically mundane, hazardous, or susceptible to errors. In 2021, the development team established the specifications for Inspecta by analyzing International Atomic Energy Agency (IAEA) documents and consulting with former IAEA inspectors and subject matter experts. This process involved aligning in-field inspection tasks with existing commercial or open-source technologies to outline a roadmap for the initial prototype of Inspecta, while also identifying areas needing further research and development. From 2022 – 2024, the focus has shifted to integrating a critical inspection activity, the examination of seals, into an early version of Inspecta. This has involved developing both the software and hardware capabilities necessary for this task. This report outlines the ongoing advancements in Inspecta's functionalities, specifically those supporting the seal examination process.

97 MATHEMATICS AND COMPUTING↗

HSI Prototypes for Human Systems Simulation Laboratory

This report describes in detail the design and features of three Human System Interface (HSI) prototypes developed by the Institutt for Energiteknikk (IFE) in support of the U.S. Department of Energy’s Light Water Reactor Sustainability Program under Contract 128420 through Idaho National Laboratory (INL). The prototypes are implemented for the Generic Pressurized Water Reactor simulator and installed in the Human Systems Simulation Laboratory at INL. The three prototypes are: 1) Power Ramp display 2) RCS Heat-up and Cool-down display 3) Estimated time to limit display The power ramp display and the RCS heat-up/cool-down display are designed to provide good visual indications to the operators on how well they are performing their task compared to their target ramp/heat-up/cool-down rate. The estimated time to limit display is designed to help operators restore levels or pressures before automatic or required manual actions are activated.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

E6D25E, HPV16 Asian variant shows specific proteomic pattern correlating in cells transformation and suppressive innate immune response

HPV16 Asian variant (HPV16As) containing E6D25E oncogene, is commonly associated with cervical cancers of Asian populations. To explore a mechanism of E6D25E oncoprotein in carcinogenesis, we compared protein profiles in human keratinocytes expressing E6D25E with E6 of HPV16 prototype (E6Pro). A human cervical keratinocyte cell line, HCK1T, was transduced with retroviruses containing E6D25E or E6Pro genes. Biological properties of E6D25E or E6Pro transduced HCK1T cells were characterized. Protein profiles of the transduced HCK1T cells were analyzed using 2D-PAGE and characterized by mass spectrometry and western blotting. Reactomes of modulated proteins were analyzed by using the Reactome Knowledgebase. The E6D25E and E6Pro oncoproteins were comparable for their abilities to degrade p53 and suppress the induction of p21, and induce cell proliferation. Interestingly, the protein profiles of the HCK1T cells transduced with E6D25E showed specific proteomic patterns different from those with E6Pro. Among altered proteins, more than 1.5-fold up- or down- regulation was observed in E6D25E-expressing cells for gp96 and keratin7 which involved in activation of TLR signaling and transformation of squamocolumnar junction cells, respectively. This report describes new cellular proteins specifically targeted by E6D25E oncoprotein that may contribute to impair immune response against viral infection and cell transformation associated with oncogenic property of HPV16As variant. - Highlights: • E6D25E HPV16 specifically modulates protein profile of human keratinocytes. • E6D25E HPV16 modulates protein profile which involves in TLR signalling and transformation of squamocolumnar junction cells. • E6D25E oncoprotein may correlate to impair of immune response against viral infection and cells transformation.

60 APPLIED LIFE SCIENCES↗

Design and Measurement of the NSLS II Correctors

The National Synchrotron Light Source II (NSLS-II) under construction at Brookhaven National Laboratory will be a new state-of-the-art 3 Gev electron storage ring designed to deliver world-leading intensity and brightness, and will produce x-rays more than 10,000 times brighter than the current NSLS at Brookhaven. The 792-meter circumference storage ring is comprised of approximately 1000 magnetic elements, 300 of which are discrete corrector magnets. The three variants are: 120 of the 100 mm aperture correctors, 60 of the 156 mm aperture correctors, and 90 of the air core correctors.[1] The 100 mm and 156 mm horizontal and vertical dipole correctors come in two varieties: with and without a DC skew quad corrector. The air core is strictly an AC horizontal and vertical dipole corrector. The specifications are listed. Discrete corrector magnets are used for the 230 horizontal and vertical steering magnets in the NSLS-II storage ring. A unique design incorporates both dipole and skew quad correctors for (DC) steering in the same magnet. Separate AC (orbit feedback) correctors have also been designed. Comparison with alternate designs are presented as well as prototype measurements.

43 PARTICLE ACCELERATORS↗

Exploring the Influence of Linker Substitution and Ratios on Cooperative Framework Flexibility through the Mixed-Linker Approach

Cooperatively flexible metal–organic frameworks that exhibit step-shaped, or Type V-like, adsorption–desorption profiles can lower requisite pressure–temperature swings and thus energy input, necessary for an array of gas storage, delivery, and separations applications. However, such benefits are lost if the pressure threshold of the adsorption and desorption steps at a given temperature does not match the conditions dictated by the application, such as H 2 storage and delivery or olefin–paraffin separations. Unfortunately, the discovery of cooperatively flexible frameworks remains wholly serendipitous and de novo design remains impossible. Accordingly, there is a great need to further our understanding of flexibility such that we can intuitively derivatize known frameworks and, ultimately, design entirely new ones to meet the requisite conditions of energy-consumptive processes. In this work, we demonstrate that the mixed-linker, or multivariate, approach is a powerful tool for the derivation of a known flexible framework, with variances in linker substitution and ratio giving rise to a family wherein significant changes to the step-shaped adsorption–desorption profiles for multiple adsorbates are observed. Specifically, we report 12 isostructural mixed-linker derivatives of CdIF-13 (sod–Cd(benzimidazolate) 2 ) with six point-modified benzimidazole linkers spontaneously synthesized through prototypical solvothermal conditions. Furthermore, each is shown by PXRD to exhibit similar reversible flexibility to CdIF-13 and by TGA and DSC to be similarly thermally stable. Isothermal gas adsorption measurements with N 2 at 77 K, CO 2 at 195 K, and propane at 298 K demonstrate the wide-ranging, adsorbate-dependent effects of linker substitution and ratio, including dramatic reductions in the adsorption threshold pressure, evolution of multiple steps, and complete absence of observable adsorption. Aided by prior crystallographic characterization of CdIF-13, the observed trends were analyzed in an attempt to resolve the influence of linker substitution and ratios on structural behavior. In total, this work illustrates how the mixed-linker approach enables the synthesis and study of a large catalog of functionally modified frameworks, which can help identify the variables that influence flexibility and sorption behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

First high-power helicon results from DIII-D

Abstract More than 0.6 MW of rf power at 476 MHz has been coupled to DIII-D plasmas by launching helicon (whistler) waves with a traveling-wave antenna (comb-line) in the fast-wave polarization (Van Compernolle et al 2021 Nucl. Fusion 61 116034) which resulted in the observation of electron heating of the core plasma with single-pass absorption based on ray-tracing in L-mode discharges. The coupling performance of the 1.5 m wide 30-element comb-line traveling-wave antenna has been consistent with expectations based on the 2015–2016 experiments on DIII-D with a low-power 12-element prototype (Pinsker et al 2018 Nucl. Fusion 58 106007). The conditioning process that was necessary to carry out high-power experiments is discussed; rf-specific impurities have not been observed. Parametric decay instabilities have been observed and are being investigated as a potential edge absorption mechanism (Porkolab et al 2023 AIP Conf. Proc. 2984 070004).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TU-AB-201-10: Novel Conformal Skin Brachytherapy Device

Purpose: A novel conformal skin brachytherapy (CSBT) device was developed to provide patient specific treatment for small inoperable lesions and irregular surfaces that are not good candidates for electron external beam, e.g. eyelids, nose, lips, ears, etc. Methods: A prototype was built and tested using radioactive seeds spaced by 1.5 mm attached to a 3D printed template. Seeds were allowed to move independently at treatment surface to conform to target geometry. Beta-emitter Praseodymium-142 (half-life: 19.12 h, average beta energy: 809 keV) and Iodine-125 Model 6711 (half-life: 59.4 days, average gamma energy: 28 keV) seeds were used to test the feasibility of the device in solid water phantom for different prescription depths and surface areas. Percent depth doses and dose profiles were analyzed. MCNPX2.6 Monte Carlo Simulation and Gafchromic EBT3 film measurements were performed for a single Pr-142 seed. Treatment with nineteen I-125 seeds was planned in BrachyVision and measured experimentally for a total dose of 500 cGy at 5.0 mm depth. Results: For a single Pr-142 seed, dose was 500.0 cGy at surface and 17.4 cGy at 5.00 mm. BrachyVision planned and film doses for I-125 seed matrix were 500 cGy and 473.5 cGy at 5 mm depth and 171.0 cGy and 201.0 cGy at 10 mm depth. Total covered surface area for Pr-142 and I-125 were 2.35 mm{sup 2} and 88.24 mm{sup 2} respectively. Profile dose fall-off showed to be very conformal to contact area with 50% of the total surface dose from a single Pr-142 and array of I-125 seeds being deposited at 0.72 mm and 0.65 mm respectively from the central axis. Conclusion: CSBT device provides a high conformal dose to small surfaces. BrachyVision can be used to predict clinical dose distributions for multiple seeds matrix. Different radioactive seeds can be used to suit prescription depth and treatment area.

60 APPLIED LIFE SCIENCES↗