Modulated infrared radiant source

A modulated, infrared radiant energy source was developed to calibrate an airborne nadir-viewing pressure modulated radiometer to be used to detect from Earth orbit trace gases in the troposphere. The technique used an 8 cm long, 0.005 cm diameter platinum-iridium wire as an isothermal, thin line radiant energy source maintained at 1200 K. A + or - 20 K signal, oscillating at controllable frequencies from dc to 20 Hz, was superimposed on it. This periodic variation of the line source energy was used to verify the pressure modulated radiometer's capability to distinguish between the signal variations caused by the Earth's background surface and the signal from the atmospheric gases of interest.

Stewart, W. F.↗

Microwave remote sensing: Active and passive. Volume 1 - Microwave remote sensing fundamentals and radiometry

The three components of microwave remote sensing (sensor-scene interaction, sensor design, and measurement techniques), and the applications to geoscience are examined. The history of active and passive microwave sensing is reviewed, along with fundamental principles of electromagnetic wave propagation, antennas, and microwave interaction with atmospheric constituents. Radiometric concepts are reviewed, particularly for measurement problems for atmospheric and terrestrial sources of natural radiation. Particular attention is given to the emission by atmospheric gases, clouds, and rain as described by the radiative transfer function. Finally, the operation and performance characteristics of radiometer receivers are discussed, particularly for measurement precision, calibration techniques, and imaging considerations.

Ulaby, F. T.↗

Thermal Infrared Observations of Lava Flows During the 1984 Mauna Loa Eruption

Thermal infrared videotape images of the flowing lava streams and the vent areas at 10.6 microns were made, as well as some broadband images in the 8 to 12 micron range (for gas plume detection). These data were calibrated with on-site hand-held radiometer measurements, in-flow thermocouple measurements, and with later laboratory kiln measurements. Infrared video data are useful in quantitatively assessing the pattern and mode of flow thermal losses, particularly with regard to radiative losses from established/incipient floating crust. The general cooling of the flows downstream was readily apparent. Upper reaches of the active flow exhibited nearly crust-free main channels, radiating at about 700 to 800 degrees C. Below about the 7500 foot level (about 8 km from the vent) the flows formed nearly continuous crust and tended to spread, become less well-defined and founder due to a reduction in slope. Nevertheless, in thermal IR observations, the surface trace of the active subsurface channel was visible, radiating at about 500 to 700 degrees C. At the active flow front, most solid crust radiated at temperatures less than 500 to 600 degrees C, however bright high temperature interiors (approximately 900 to 1000 degrees C) were clearly visible though evolving fissures.

Pieri, D. C.↗

Accounting For Nonlinearity In A Microwave Radiometer

Simple mathematical technique found to account adequately for nonlinear component of response of microwave radiometer. Five prescribed temperatures measured to obtain quadratic calibration curve. Temperature assumed to vary quadratically with reading. Concept not limited to radiometric application; applicable to other measuring systems in which relationships between quantities to be determined and readings of instruments differ slightly from linearity.

Stelzried, Charles T.↗

Polar Geophysics Products Derived from AVHRR: The "AVHRR Polar Pathfinder

This NOAA/NASA Pathfinder effort was established to locate, acquire, and process Advanced Very High Resolution Radiometer (AVHRR) imagery into geo-located and calibrated radiances, cloud masks, surface clear-sky broadband albedo, clear-sky skin temperatures, satellite viewing times, and viewing and solar geometry for the, high-latitude portions of the northern and southern hemispheres (all area north of 48N and south of 53S). AVHRR GAC data for August 1981 - July 1998 were acquired, with some gaps remaining, and processed into twice-daily 5-km grids, with some products also provided at 25-km resolution. AVHRR LAC data for 3.5 years of coverage in the northern hemisphere and 2.75 years of coverage in the southern hemisphere were processed into 1.25-km grids for the same suite of products. The resulting data sets are presently being transferred to the National Snow and Ice Data Center (NSIDC) for archiving and distribution. Using these data, researchers now have at their disposal an extensive AVHRR data set for investigations of high-latitude processes. In addition, the data lend themselves to development and testing of algorithms. The products are particularly relevant for climate research and algorithm development as applied to relatively long time periods and large areas.

Maslanik, James↗

AVHRR-Based Polar Pathfinder Products: Evaluation, Enhancement and Transition to MODIS

The Advanced Very High Resolution Radiometer (AVHRR)-Based Polar Pathfinder (APP) products include calibrated AVHRR channel data, surface temperatures, albedo, satellite scan and solar geometries, and cloud mask, all composited into twice-per-day images, and daily averaged fields of sea ice motion, for regions poleward of 50 latitude. Our general goals under this grant: (1) Quantify the APP accuracy and sources of error by comparing Pathfinder products with field measurements; (2) Determine the consistency of mean fields and trends in comparison with longer time series of available station data and forecast model output; (3) Investigate the consistency of the products between the different AVHRR instruments over the 1982-present period of the NOAA program; and (4) Compare and annual cycle of the APP products with MODIS to establish a baseline for extending Pathfinder-type products into the new ESE period.

Fowler, Charles↗

Real Time Monitoring of Flooding from Microwave Satellite Observations

We have developed a new method for making high-resolution flood extent maps (e.g., at the 30-100 m scale of digital elevation models) in real-time from low-resolution (20-70 km) passive microwave observations. The method builds a "flood-potential" database from elevations and historic flood imagery and uses it to create a flood-extent map consistent with the observed open water fraction. Microwave radiometric measurements are useful for flood monitoring because they sense surface water in clear-or-cloudy conditions and can provide more timely data (e.g., compared to radars) from relatively wide swath widths and an increasing number of available platforms (DMSP, ADEOS-II, Terra, NPOESS, GPM). The chief disadvantages for flood mapping are the radiometers' low resolution and the need for local calibration of the relationship between radiances and open-water fraction. We present our method for transforming microwave sensor-scale open water fraction estimates into high-resolution flood extent maps and describe 30-day flood map sequences generated during a retrospective study of the 1993 Great Midwest Flood. We discuss the method's potential improvement through as yet unimplemented algorithm enhancements and expected advancements in microwave radiometry (e.g., improved resolution and atmospheric correction).

Galantowicz, John F.↗

Clouds and Earth Radiant Energy System (CERES), a Review: Past, Present and Future

The Clouds and Earth Radiant Energy System (CERES) project s objectives are to measure the reflected solar radiance (shortwave) and Earth-emitted (longwave) radiances and from these measurements to compute the shortwave and longwave radiation fluxes at the top of the atmosphere (TOA) and the surface and radiation divergence within the atmosphere. The fluxes at TOA are to be retrieved to an accuracy of 2%. Improved bidirectional reflectance distribution functions (BRDFs) have been developed to compute the fluxes at TOA from the measured radiances with errors reduced from ERBE by a factor of two or more. Instruments aboard the Terra and Aqua spacecraft provide sampling at four local times. In order to further reduce temporal sampling errors, data are used from the geostationary meteorological satellites to account for changes of scenes between observations by the CERES radiometers. A validation protocol including in-flight calibrations and comparisons of measurements has reduced the instrument errors to less than 1%. The data are processed through three editions. The first edition provides a timely flow of data to investigators and the third edition provides data products as accurate as possible with resources available. A suite of cloud properties retrieved from the MODerate-resolution Imaging Spectroradiometer (MODIS) by the CERES team is used to identify the cloud properties for each pixel in order to select the BRDF for each pixel so as to compute radiation fluxes from radiances. Also, the cloud information is used to compute radiation at the surface and through the atmosphere and to facilitate study of the relationship between clouds and the radiation budget. The data products from CERES include, in addition to the reflected solar radiation and Earth emitted radiation fluxes at TOA, the upward and downward shortwave and longwave radiation fluxes at the surface and at various levels in the atmosphere. Also at the surface the photosynthetically active radiation and ultraviolet radiation (total, UVA and UVB) are computed. The CERES instruments aboard the Terra and Aqua spacecraft have served well past their design life times. A CERES instrument has been integrated onto the NPP platform and is ready for launch in 2011. Another CERES instrument is being built for launch in 2014, and plans are being made for a series of follow-on missions.

Smith, G. L.↗

Multi-Frequency Radiometer-Based Soil Moisture Retrieval and Algorithm Parameterization Using In Situ Sites

L-band brightness temperature (TB) has been shown to provide the best sensitivity to soil moisture (SM) although C- and X-band based products offer a longer time-series from satellite-based measurements. Currently, global coverage SM is routinely produced from spaceborne measurements using all three frequency bands, but despite continued validation efforts of the products, the relative characteristics and performance of these observations have not been fully established. Therefore, this study focused on the parametrization of SM retrieval algorithms at L-, C- and X-bands using TB observations from the L-band radiometer on NASA's SM Active Passive (SMAP) mission and the C- and X-band channels of JAXA's Advanced Microwave Scanning Radiometer 2 (AMSR2) onboard the GCOM-W satellite. These can be applied in global SM retrieval algorithms using either one of the frequencies or a combination of them. The reference in situ SM data was obtained from 12 core validation sites across various land cover types around the world. The investigation highlighted the known challenges of retrieving SM from C- and X-band data compared to the higher sensitivity of the L-band data. Even with a site-specific retrieval algorithm parameterization, the mean correlation of the C- and X-band retrievals for the core validation site SM measurement were much lower than that for L-band, being 0.52 (0.54) and 0.45 (0.47) for vertical (horizontal) polarization, respectively, while for the L-band retrieval the corresponding values were 0.81 (0.77). The parameterization exercise showed that matching the C- and X-band TB measurements with an emission model was not difficult; the problem was relating the observations to SM under the influence of large roughness and vegetation effects. As a result, parameter optimization produced values for some sites that were not realistic or did not allow any practical sensitivity to SM at C- and X-band. Considering the L-band observations, the parameter optimization resulted in superior bias performance as compared to the operational SMAP product parameterization, but the sensitivity to SM changes (R and unbiased root mean square difference) did not improve markedly, or in some cases degraded at the expense of a smaller bias.

passive microwave↗

A ratioing radiometer for use with a solar diffuser

The use of an on-board solar diffuser has been proposed to monitor the in-flight calibration of satellite sensors. This paper presents the preliminary specifications and design for a ratioing radiometer, to be used to determine the change in radiance of the solar diffuser. The issues involved in spectral channel selection are discussed and the effects of stray light are presented. An error analysis showing the benefit of the ratioing radiometer is included.

Palmer, James M.↗

Impact of Microwave Sounder (and Imager) Calibration on Precipitation for the Global Precipitation Measurement (GPM) Mission

Cross-track microwave sounders make up a significant percentage of the radiometers included in the Global Precipitation Measurement (GPM) constellation. Therefore, it is important to properly assess the calibration of each sounder instrument and to understand the impact of the calibration on the derived precipitation rates. This ensures an accurate precipitation product is produced for the entire constellation. This paper will use data from past and current microwave sounders to show how offsets in the calibration can impact the precipitation using the GPM Level 2 GPROF algorithm. Potential improvements to the instrument calibration will be assessed by analyzing how they would positively impact the precipitation trends and agreement among the constellation sensors.

Microwave radiometry↗

Results from Solar Reflective Band End-to-End Testing for VIIRS F1 Sensor Using T-SIRCUS

Verification of the Visible Infrared Imager Radiometer Suite (VIIRS) End-to-End (E2E) sensor calibration is highly recommended before launch, to identify any anomalies and to improve our understanding of the sensor on-orbit calibration performance. E2E testing of the Reflective Solar Bands (RSB) calibration cycle was performed pre-launch for the VIIRS Fight 1 (F1) sensor at the Ball Aerospace facility in Boulder CO in March 2010. VIIRS reflective band calibration cycle is very similar to heritage sensor MODIS in that solar illumination, via a diffuser, is used to correct for temporal variations in the instrument responsivity. Monochromatic light from the NIST T-SIRCUS was used to illuminate both the Earth View (EV), via an integrating sphere, and the Solar Diffuser (SD) view, through a collimator. The collimator illumination was cycled through a series of angles intended to simulate the range of possible angles for which solar radiation will be incident on the solar attenuation screen on-orbit. Ideally, the measured instrument responsivity (defined here as the ratio of the detector response to the at-sensor radiance) should be the same whether the EV or SD view is illuminated. The ratio of the measured responsivities was determined at each collimator angle and wavelength. In addition, the Solar Diffuser Stability Monitor (SDSM), a ratioing radiometer designed to track the temporal variation in the SD BRF by direct comparison to solar radiation, was illuminated by the collimator. The measured SDSM ratio was compared to the predicted ratio. An uncertainty analysis was also performed on both the SD and SDSM calibrations.

McIntire, Jeff↗

Calibration of VIIRS F1 Sensor Fire Detection Band Using lunar Observations

Visible Infrared Imager Radiometer Suite (VIIRS) Fight 1 (Fl) sensor includes a fire detection band at roughly 4 microns. This spectral band has two gain states; fire detection occurs in the low gain state above approximately 345 K. The thermal bands normally utilize an on-board blackbody to provide on-orbit calibration. However, as the maximum temperature of this blackbody is 315 K, the low gain state of the 4 micron band cannot be calibrated in the same manner as the rest of the thermal bands. Regular observations of the moon provide an alternative calibration source. The lunar surface temperature has been recently mapped by the DIVINER sensor on the LRO platform. The periodic on-board high gain calibration along with the DIVINER surface temperatures was used to determine the emissivity and solar reflectance of the lunar surface at 4 microns; these factors and the lunar data are then used to fit the low gain calibration coefficients of the 4 micron band. Furthermore, the emissivity of the lunar surface is well known near 8.5 microns due to the Christiansen feature (an emissivity maximum associated with Si-O stretching vibrations) and the solar reflectance is negligible. Thus, the 8.5 micron band is used for relative calibration with the 4 micron band to de-trend any temporal variations. In addition, the remaining thermal bands are analyzed in a similar fashion, with both calculated emissivities and solar reflectances produced.

McIntire, Jeff↗

Suomi-NPP VIIRS Day-Night Band On-Orbit Calibration and Performance

The Suomi national polar-orbiting partnership Visible Infrared Imaging Radiometer Suite (VIIRS) instrument has successfully operated since its launch in October 2011. The VIIRS day-night band (DNB) is a panchromatic channel covering wavelengths from 0.5 to 0.9 microns that is capable of observing Earth scenes during both daytime and nighttime at a spatial resolution of 750 m. To cover the large dynamic range, the DNB operates at low-, middle-, and high-gain stages, and it uses an on-board solar diffuser (SD) for its low-gain stage calibration. The SD observations also provide a means to compute the gain ratios of low-to-middle and middle-to-high gain stages. This paper describes the DNB on-orbit calibration methodology used by the VIIRS characterization support team in supporting the NASA Earth science community with consistent VIIRS sensor data records made available by the land science investigator-led processing systems. It provides an assessment and update of the DNB on-orbit performance, including the SD degradation in the DNB spectral range, detector gain and gain ratio trending, and stray-light contamination and its correction. Also presented in this paper are performance validations based on Earth scenes and lunar observations, and comparisons to the calibration methodology used by the operational interface data processing segment.

Chen, Hongda↗

Analysis of Non-Stationary Radiometer Gain Via Ensemble Detection

Analysis of non-stationary radiometer gain is challenging as it cannot be independently monitored and may display different characteristics under different calibration schemes. Using a novel technique called Ensemble Detection analysis we can characterize this type of radiometer gain under certain circumstances.

Earth Resources and Remote Sensing↗

The effect of tropospheric fluctuations on the accuracy of water vapor radiometry

Line-of-sight path delay calibration accuracies of 1 mm are needed to improve both angular and Doppler tracking capabilities. Fluctuations in the refractivity of tropospheric water vapor limit the present accuracies to about 1 nrad for the angular position and to a delay rate of 3x10(exp -13) sec/sec over a 100-sec time interval for Doppler tracking. This article describes progress in evaluating the limitations of the technique of water vapor radiometry at the 1-mm level. The two effects evaluated here are: (1) errors arising from tip-curve calibration of WVR's in the presence of tropospheric fluctuations and (2) errors due to the use of nonzero beamwidths for water vapor radiometer (WVR) horns. The error caused by tropospheric water vapor fluctuations during instrument calibration from a single tip curve is 0.26 percent in the estimated gain for a tip-curve duration of several minutes or less. This gain error causes a 3-mm bias and a 1-mm scale factor error in the estimated path delay at a 10-deg elevation per 1 g/cm(sup 2) of zenith water vapor column density present in the troposphere during the astrometric observation. The error caused by WVR beam averaging of tropospheric fluctuations is 3 mm at a 10-deg elevation per 1 g/cm(sup 2) of zenith water vapor (and is proportionally higher for higher water vapor content) for current WVR beamwidths (full width at half maximum of approximately 6 deg). This is a stochastic error (which cannot be calibrated) and which can be reduced to about half of its instantaneous value by time averaging the radio signal over several minutes. The results presented here suggest two improvements to WVR design: first, the gain of the instruments should be stabilized to 4 parts in 10(exp 4) over a calibration period lasting 5 hours, and second, the WVR antenna beamwidth should be reduced to about 0.2 deg. This will reduce the error induced by water vapor fluctuations in the estimated path delays to less than 1 mm for the elevation range from zenith to 6 deg for most observation weather conditions.

Wilcox, J. Z.↗

The Spectral Information Based Angular Correction Methodology for Satellite Intercalibration Applications

Satellite inter-calibration often requires collocated observations with minimized discrepancies in sun-view angles, observation times, and sensor characteristics. The collocation criteria directly impact achievable inter-calibration accuracy. Addressing potential angular mismatches in inter-calibration samples is critical but not as fully recognized and addressed as spatial-temporal mismatches in many studies. To achieve high-accuracy corrections for errors due to mismatched sun-view geometry angles, an angular correction algorithm has been developed for the Climate Absolute Radiance and Refractivity Observatory Pathfinder (CPF) mission. This algorithm uses spectral correlation relationships to estimate differences in spectral radiances measured at different angles. This methodology can be extended for inter-calibrations between sensors measuring band radiances across a broad spectral region. We demonstrate its application in reducing angular mismatch errors between collocated measurements of multi-spectral imaging sensors, using the inter-calibration between the Moderate Resolution Imaging Spectrometer (MODIS) and the Visible Infrared Imaging Radiometer Suite (VIIRS) as an example. The angular correction allows for more relaxed collocation criteria so that more satellite-based inter-calibration samples can be utilized. Furthermore, implementing the angular correction algorithm improves inter-calibration accuracy in applications where angular mismatch errors have not been explicitly addressed previously.

Wan Wu↗

Methods of Earth View Based Calibration of the Response Versus Scan Angle of the MODIS Reflective Solar Bands

The MODIS instruments on the Terra and Aqua spacecraft are cross-track scanning radiometers that view the Earth scene, a space view port, and the on-board calibrators using a two-sided scan mirror. The reflectivity of the scan mirror varies with the angle of the incident light, and changes in this response versus scan angle (RVS) need to be tracked on orbit in order to maintain accurate calibration. In this paper, we review various methods of RVS calibration of the reflective solar bands using pseudo-invariant desert targets and discuss potential advantages and disadvantages for use in future calibration.

Twedt, Kevin A.↗