Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

In-flight comparisons of boundary-layer and wake measurement probes for incompressible flow

The results are presented of in-flight comparisons of a number of boundary-layer and wake measurement probes suitable for low-speed flight-test investigations. The tested boundary-layer probes included a traversing total-pressure probe and a hot-film probe mounted on an internally-mounted drive mechanism, a curved and a straight boundary-layer rake, and a traversing hot-film probe with an externally-mounted drive mechanism. The wake measuring devices included a traversing, self-aligning probe, a wake rake, and an integrating wake rate. The boundary-layer data are compared with a common reference velocity profile and comments given regarding the accuracy of the static-pressure and total-pressure measurements. Discussions on the various calibration presentations used with hot-wire and hot-film sensors and various aspects of improving the accuracy of hot-film sensor results are given in the appendix of this report.

Mertaugh, L. J., Jr.↗

Low-power anemometer

Device allows wind speeds to be measured with less power by alternating hot-wire or hot-film heating periods with measurement periods. System includes reference auxiliary circuits to generate V sub ref and ramp voltage (E sub 3) and reference half of bridge circuit. Circuit permits use of several sensing films with common temperature compensation sensor.

Gilje, R. I.↗

Electrochemical devices comprising compressed gas solvent electrolytes

Disclosed are novel electrolytes, and techniques for making and devices using such electrolytes, which are based on compressed gas solvents. Unlike conventional electrolytes, disclosed electrolytes are based on “compressed gas solvents” mixed with various salts, referred to as “compressed gas electrolytes.” Various embodiments of a compressed gas solvent includes a material that is in a gas phase and has a vapor pressure above an atmospheric pressure at a room temperature. The disclosed compressed gas electrolytes can have wide electrochemical potential windows, high conductivity, low temperature capability and/or high pressure solvent properties.

25 ENERGY STORAGE↗

Design of Nuclear Criticality Safety Framework for Hands-on Construction of Fast Systems Over Ranges of Multiplication

Since 1945, Los Alamos National Laboratory (LANL) has performed critical experiments, primarily at the Los Alamos Critical Experiments Facility (LACEF) at Technical Area 18 (TA-18). Since 2011, these experiments have been conducted by the National Criticality Experiments Research Center (NCERC), operated by LANL, at the Device Assembly Facility (DAF) in the Nevada National Security Site (NNSS). These experiments utilize various types of Special Nuclear Material (SNM). Some of these experiments utilize what is referred to as the Rocky Flat Shells, which are called such as they came from the Rocky Flats Plant. These concentric hemi-shells are made of Highly Enriched Uranium (HEU), which is 93 w/o 235U. Fig. 1. Subset of the Rocky Flat Shells LANL is designing a new subcritical hands-on experiment with the goal of achieving a neutron multiplication in the range of 50 to 200, which correlates to Keff values of 0.98 to 0.995. ANSI/ANS-1 is the standard for Conduct of Critical Experiments which governs critical operations at NCERC. Section 3.9 of ANSI/ANS-1 states that when manipulating a critical assembly by hand, the predicted k eff of a known configuration should not exceed 0.95 (a neutron multiplication of 20). This presents a challenge, as this system would have a higher multiplication than 20 and the assembly would have to remain subcritical in normal and credible accident scenarios. To ensure the safety of such an assembly, the different normal and abnormal conditions that could alter the criticality 1 MCNP® and Monte Carlo N-Particle® are registered trademarks owned by Triad National Security, LLC, manager and operator of Los Alamos National Laboratory. Any third party use of such registered marks should be properly of the system must be considered and analyzed. If such a condition is deemed to be credible, it will be further investigated using the Monte Carlo N-Particle (MCNP) transport code. If the results of these simulations show that a k eff larger than one could be possible, modifications to the assembly will be made until such an event is deemed no longer possible.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An investigation for the development of an integrated optical data preprocessor

A laboratory model of a 16 channel integrated optical data preprocessor was fabricated and tested in response to a need for a device to evaluate the outputs of a set of remote sensors. It does this by accepting the outputs of these sensors, in parallel, as the components of a multidimensional vector descriptive of the data and comparing this vector to one or more reference vectors which are used to classify the data set. The comparison is performed by taking the difference between the signal and reference vectors. The preprocessor is wholly integrated upon the surface of a LiNbO3 single crystal with the exceptions of the source and the detector. He-Ne laser light is coupled in and out of the waveguide by prism couplers. The integrated optical circuit consists of a titanium infused waveguide pattern, electrode structures and grating beam splitters. The waveguide and electrode patterns, by virtue of their complexity, make the vector subtraction device the most complex integrated optical structure fabricated to date.

Verber, C. M.↗

Oxygen Candle Background for Subs and Space

"At any time and without warning, a submarine may have to remain submerged for several days on account of the presence of the enemy, or rough weather, or serious accident to the machinery. Fortunately such occurrences are rare; but every commanding officer must be prepared to meet such an emergency that will afford his men the greatest possible chance of survival." Reference (1) This quotation is taken from a review of submarine air purification technology published by the Bureau of Medicine and Surgery in 1919. At that time, the U.S. Navy had just begun to experiment with possible air purification devices and supplies of oxygen that might permit submarines to remain submerged longer that the untreated closed atmosphere would allow. Submariners were exposed to elevated levels of carbon dioxide and reduced levels of oxygen that would be considered completely unacceptable by current standards. It was a different world, but humans are still humans, and the requirements for safe and effective functioning in a self-contained environment are really unchanged. The maximum submergence time for submarines as published in that work was approximately 48 hours, reference (1) In early submarines, the preferred supply of oxygen was 1800 psig compressed gas bled into the boat as needed, references (1,2). The need for added oxygen was occasionally "measured" by the physiological impact on the crew rather than a reliable instrument, reference (1). The design of submarine oxygen supply was limited to approximately 25 day submerged operation, reference (2). It was not until 1958 that U.S. submarines were able to carry out dives beyond that period and necessitated new sources of oxygen, reference (2). A curious second source of oxygen at the time was compressed air vessels that were bled into the boat while "vitiated" air (air with reduced oxygen and elevated carbon dioxide) from the opposite end of the boat was compressed into waiting empty vessels, reference (1). The periodic use of pressurized air to control oxygen caused swings in ambient pressure that was uncomfortable to the crew, reference (1). As early as 1919, liquid oxygen was a commercially available product and its use on submarines was contemplated, reference (1). It is interesting that even at this date, 1919, the danger of oils or greases when exposed to compressed or liquid oxygen was recognized: "One precaution must be always taken. No oil or grease should be used in the gauge or fittings or a dangerous explosion may result."

Graf, John↗

Inertial rotation sensor

Mechanism for inertial rotation sensing device for measuring spectral lines of rotating atoms seen by rotating observer

ROTATING MACHINE↗

Development of a Shuttle Infrared Telescope Facility /SIRTF/ fine guidance sensor

Fine guidance technology development for the Shuttle Infrared Telescope Facility (SIRTF) centers upon the use of a single multiple-star-tracking sensor to provide the position information necessary to produce three-axis attitude control signals for precision payload pointing. The effort described in this paper is concerned with the development of a fine guidance sensor that employs a high-density charge-coupled imaging device for producing position information signals by using star fields. Multiple star position information produces three-axis position error signals that are used to update inertial reference gyros. The sensor employs advanced position interpolation algorithms to enhance field-of-view resolution and to correct for optical aberrations inherent in spatially chopped star images resulting from the telescope's movable secondary mirror. Operation of the sensor is under the control of a high-performance microcomputer that provides both autonomy and flexibility in a guidance application.

Salomon, P. M.↗

Virtual Ultrasound Guidance for Inexperienced Operators

Medical ultrasound or echocardiographic studies are highly operator-dependent and generally require lengthy training and internship to perfect. To obtain quality echocardiographic images in remote environments, such as on-orbit, remote guidance of studies has been employed. This technique involves minimal training for the user, coupled with remote guidance from an expert. When real-time communication or expert guidance is not available, a more autonomous system of guiding an inexperienced operator through an ultrasound study is needed. One example would be missions beyond low Earth orbit in which the time delay inherent with communication will make remote guidance impractical. The Virtual Ultrasound Guidance system is a combination of hardware and software. The hardware portion includes, but is not limited to, video glasses that allow hands-free, full-screen viewing. The glasses also allow the operator a substantial field of view below the glasses to view and operate the ultrasound system. The software is a comprehensive video program designed to guide an inexperienced operator through a detailed ultrasound or echocardiographic study without extensive training or guidance from the ground. The program contains a detailed description using video and audio to demonstrate equipment controls, ergonomics of scanning, study protocol, and scanning guidance, including recovery from sub-optimal images. The components used in the initial validation of the system include an Apple iPod Classic third-generation as the video source, and Myvue video glasses. Initially, the program prompts the operator to power-up the ultrasound and position the patient. The operator would put on the video glasses and attach them to the video source. After turning on both devices and the ultrasound system, the audio-video guidance would then instruct on patient positioning and scanning techniques. A detailed scanning protocol follows with descriptions and reference video of each view along with advice on technique. The program also instructs the operator regarding the types of images to store and how to overcome pitfalls in scanning. Images can be forwarded to the ground or other site when convenient. Following study completion, the video glasses, video source, and ultrasound system are powered down and stored. Virtually any equipment that can play back video can be used to play back the program. This includes a DVD player, personal computer, and some MP3 players.

Caine, Timothy↗

Energy management system, method of controlling one or more energy storage devices and control unit for one or more power storage units

Systems, methods and apparatuses are provided for reducing peak energy demand and to smooth intermittent energy profiles from onsite variable energy sources and loads. Some embodiments use system level and device level analysis and optimization to adaptively adjust the operation of a behind the meter energy storage (BMES) to smooth out energy generation variabilities and follow a reference load signal, including at short time resolutions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluation of Hands-Free Devices for the Display of Maintenance Procedures

Over the past year, NASA's focus has turned to crewed long duration and exploration missions. On these journeys, crewmembers will be required to execute thousands of procedures to maintain life support systems, check out space suits, conduct science experiments, and perform medical exams. To support the many complex tasks crewmembers undertake in microgravity, NASA is interested in providing crewmembers a hands-free work environment to promote more efficient operations. The overarching objective is to allow crewmembers to use both of their hands for tasks related to their mission, versus holding a paper manual or interacting with a display. The use of advanced, hands-free tools will undoubtedly make the crewmembers task easier, but they can also add to overall task complexity if not properly designed. A leading candidate technology for supporting a hands-free environment is the Head-Mounted Display (HMD). A more recent technology (e-book reader) that could be easily temp-stowed near the work area is also a potential hands-free solution. Previous work at NASA involved the evaluation of several commercially available HMDs for visual quality, comfort, and fit, as well as suitability for use in microgravity. Based on results from this work, three HMDs were selected for further evaluation (along with an e-book reader), using International Space Station (ISS)-like maintenance procedures. Two evaluations were conducted in the Space Station Mockup and Trainer Facility (SSMTF) located at the NASA Johnson Space Center (building 9). The SSMTF is a full scale, medium fidelity replica of the pressurized portions of the ISS. It supports crew training such as ingress and egress, habitability, and emergency procedures. In each of the two evaluations, the participants performed two maintenance procedures. One maintenance procedure involved inspecting air filters in a life support system and replacing them with a clean filter if one were found to be contaminated. The second maintenance procedure focused on working in a confined space; specifically, pulling down a rack to inspect wiring configurations, and rewiring in a different pattern. The maintenance procedures were selected to assess mobility, tool use, and access to multiple document sources during task performance. That is, the participant had to move from rack to rack, use a wrench, a camera, etc., replace components, and refer to diagrams to complete tasks. A constraint was imposed that the ISS-like format of the procedures was to be retained, and not modified or optimized for the electronic device ("plug and play" approach). This was based on future plans to test with real procedures on ISS.

Ronald B Hoffman↗

Sample Preparation Methods for Targeted Single-Cell Proteomics

We compared three cell isolation and two proteomic sample preparation methods for single-cell and near-single-cell analysis. Whole blood was used to quantify hemoglobin (Hb) and glycated-Hb (gly-Hb) in erythrocytes using targeted mass spectrometry and stable isotope-labeled standard peptides. Each method differed in cell isolation and sample preparation as follows: 1) FACS and automated preparation in one-pot for trace samples (autoPOTS); 2) limited dilution via microscopy and a novel rapid one-pot sample preparation method that circumvented the need for the solid-phase extraction, low-volume liquid handling instrumentation and humidified incubation chamber; and 3) CellenONE-based cell isolation and the same one-pot sample preparation method used for limited dilution. Only the CellenONE device routinely isolated single-cells from which Hb was measured to be 540–660 amol per red blood cell (RBC), which was comparable to the calculated SI reference range for mean corpuscular hemoglobin (390–540 amol/RBC). FACSAria sorter and limited dilution could routinely isolate single-digit cell numbers, to reliably quantify CMV-Hb heterogeneity. Finally, we observed that repeated measures, using 5–25 RBCs obtained from N = 10 blood donors, could be used as an alternative and more efficient strategy than single RBC analysis to measure protein heterogeneity, which revealed multimodal distribution, unique for each individual.

59 BASIC BIOLOGICAL SCIENCES↗

Prediction methods for jet V/STOL propulsion aerodynamics

The current status of prediction methods for propulsive flows and propulsion-induced effects which occur on jet V/STOL aircraft is reviewed. Among the major topics studied are flows in propulsive ducts, propulsion-induced ground and thermal effects, aerodynamic loads induced during V/STOL and transition flight, flow vectoring devices, and thrust augmented ejector and lift-fan studies. The current predictive capability in jet V/STOL propulsion aerodynamics is assessed. Future research needs are identified, with particular reference to activities that can improve the usefulness of prediction methods for jet V/STOL aircraft.

Platzer, M. F.↗

Laser beam manifold and particle photography system for use in fluid velocity measurements

A laser beam manifold and particle photography system has been developed for use in fluid velocity measurements. The laser manifold is a device which transforms a single laser beam into several uniform parallel beams. By orienting two manifolds mutually perpendicular, an optical grid can be formed which acts as a reference for fluid velocity measurements. This optical grid is for all practical purposes totally nonperturbing to the flow. Tracer particles moving in the plane of the grid are then photographed to yield fluid velocities that can be measured relative to the optical grid. System construction and theory are presented.

Owen, R. B.↗

Use of vacuum tubes in test instrumentation for measuring characteristics of fast high-voltage semiconductor devices

Circuits are described that permit measurement of fast events occurring in power semiconductors. These circuits were developed for the dynamic characterization of transistors used in inductive-load switching applications. Fast voltage clamping using vacuum diodes is discussed, and reference is made to a unique circuit that was built for performing nondestructive, reverse-bias, second-breakdown tests on transistors.

Berning, D.↗

Pairwise Comparison of Voltage Sets

Optical preprocessor compares 16 incoming signals with reference voltages. Integrated optical substraction to take "vector difference" of two sets of analog voltages. Applications include satellite onboard processing of pictorial data so data not useful discardes; device recognizes presence of accessive cloud cover and signals hault to data transmission.

Verber, C. M.↗

Joint-transform correlator systems using deformable-mirror spatial light modulators

Two joint-transform correlator systems based on deformable-mirror-device (DMD) spatial light modulators and CCD video cameras are described. The system designs provide for real-time correlation between video-formatted input scenes and stored reference images. The DMD light modulators are used exclusively for inputting data in the optical stages of these systems, and the CCD cameras are used to provide the critical square-law detection required in joint-transform achitectures. Experimental verification of the functionality of these DMD/CCD joint-transform systems is also presented.

Florence, James M.↗

VLBI Data Longevity

The current cache of S/X-band geodetic/astrometric VLBI data accumulated since 1979 is approx.4.2 million observations and is increasing by approx.300,000 observations per year. The long time interval and access to all such VLBI data for re-analysis have contributed to their usefulness for the terrestrial and celestial reference frames, Earth orientation parameters, tidal and nontidal loading, and troposphere. While data access and integrity have been maintained through the Mark III data base system as storage devices and media have evolved, past transitions have been major projects. A new format and retention concept to ensure eternal archiving and access should make use of self-documentation, generalized media, network connectivity and multiple redundancy. Similarly permanent organizations or sequences of organizations are also necessary.

Ma, Chopo↗