Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Evaluating Core Quality for a Mars Sample Return Mission

Sample return missions, including the proposed Mars Sample Return (MSR) mission, propose to collect core samples from scientifically valuable sites on Mars. These core samples would undergo extreme forces during the drilling process, and during the reentry process if the EEV (Earth Entry Vehicle) performed a hard landing on Earth. Because of the foreseen damage to the stratigraphy of the cores, it is important to evaluate each core for rock quality. However, because no core sample return mission has yet been conducted to another planetary body, it remains unclear as to how to assess the cores for rock quality. In this report, we describe the development of a metric designed to quantitatively assess the mechanical quality of any rock cores returned from Mars (or other planetary bodies). We report on the process by which we tested the metric on core samples of Mars analogue materials, and the effectiveness of the core assessment metric (CAM) in assessing rock core quality before and after the cores were subjected to shocking (g forces representative of an EEV landing).

Mars samples↗

Brain‐age prediction: Systematic evaluation of site effects, and sample age range and size

Abstract Structural neuroimaging data have been used to compute an estimate of the biological age of the brain (brain‐age) which has been associated with other biologically and behaviorally meaningful measures of brain development and aging. The ongoing research interest in brain‐age has highlighted the need for robust and publicly available brain‐age models pre‐trained on data from large samples of healthy individuals. To address this need we have previously released a developmental brain‐age model. Here we expand this work to develop, empirically validate, and disseminate a pre‐trained brain‐age model to cover most of the human lifespan. To achieve this, we selected the best‐performing model after systematically examining the impact of seven site harmonization strategies, age range, and sample size on brain‐age prediction in a discovery sample of brain morphometric measures from 35,683 healthy individuals (age range: 5–90 years; 53.59% female). The pre‐trained models were tested for cross‐dataset generalizability in an independent sample comprising 2101 healthy individuals (age range: 8–80 years; 55.35% female) and for longitudinal consistency in a further sample comprising 377 healthy individuals (age range: 9–25 years; 49.87% female). This empirical examination yielded the following findings: (1) the accuracy of age prediction from morphometry data was higher when no site harmonization was applied; (2) dividing the discovery sample into two age‐bins (5–40 and 40–90 years) provided a better balance between model accuracy and explained age variance than other alternatives; (3) model accuracy for brain‐age prediction plateaued at a sample size exceeding 1600 participants. These findings have been incorporated into CentileBrain ( https://centilebrain.org/#/brainAGE2 ), an open‐science, web‐based platform for individualized neuroimaging metrics.

60 APPLIED LIFE SCIENCES↗

Microbiomes of frozen blood plasma samples reveal potential pathogens in wild birds and rodents

The lack of genomic data on pathogens from wildlife severely limits our ability to track transmission patterns and trace the origins of an outbreak. There are currently millions of wildlife samples in biobanks around the world, including blood samples. Blood has traditionally been viewed as a sterile environment in healthy individuals, but recent evidence suggests that this is not the case, especially for wild animals. Our goal was to determine whether frozen plasma samples can be surveyed using 16S sequencing to provide information about potential hosts for pathogens for a more complete understanding of disease systems. We sequenced blood plasma from wild North American deer mice ( Peromyscus maniculatus ) and American kestrels ( Falco sparverius ) that were cryogenically stored for 7 and 13 years, respectively, and compared two DNA extraction kits. The kestrel samples contained a very high number of reads that could not be identified to phylum compared to the mouse samples. The two kits differed in the phyla and genera that were detected, and the Zymo kit, which is optimized for plasma and serum, produced more high-quality reads for both kestrel and mouse samples. We identified several pathogenic genera, including Mycoplasma, Escherichia-Shigella , and Bartonella . Sequencing blood samples for pathogens could potentially have broad applications for identifying important reservoir hosts for pathogen transmission and provide a reduced set of species on which to follow up.

59 BASIC BIOLOGICAL SCIENCES↗

Opening doors to physical sample tracking and attribution in Earth and environmental sciences

Physical samples and their associated data and metadata underpin scientific discoveries across disciplines and can enable new science when appropriately archived. However, there are significant gaps in current practices and infrastructure that prevent accurate provenance tracking, reproducibility, and attribution. For most samples, descriptive metadata are often sparse, inaccessible, or absent. Samples and associated data and metadata may also be scattered across numerous physical collections, data repositories, laboratories, data files, and papers with no clear linkage or provenance tracking as new information is generated over time. The Earth Science Information Partners (ESIP) Physical Samples Curation Cluster has therefore developed guidance for scientific authors on ‘Publishing Open Research Using Physical Samples.’ This involved synthesizing existing practices, gathering community feedback, and assessing real-world examples. We identified improvements needed to enable authors to efficiently cite and link Earth science samples and related data, and track their use. Our goal is to help improve discoverability, interoperability, and reuse of physical samples, and associated data and metadata. Though primarily focused on the needs of Earth and environmental sciences, these guidelines are broadly applicable.

58 GEOSCIENCES↗

ZTF-SEDm Type Ia supernova sample for Twins Embedding spectrophotometric standardization

Aims. This paper has two aims: the first aim is to build a large homogeneous spectrophotometric sample of Type Ia supernovae (SNe Ia) from the second data release of the Zwicky Transient Facility (ZTF DR2). We used the spectrum sample from the low-resolution ( R ∼ 100) SEDmachine (SEDm) Integral Field Spectrograph (IFS) that gathered 3069 spectra. This is one of the largest samples of such collections that can attempt to reproduce the Twins Embedding (TE) spectrophotometric standardization method. This is our second objective. The method was developed based on high-quality spectra from 200 SNe Ia of the Nearby Supernova factory (SNfactory) and led to an exceptionally low value of 0.073 mag for the intrinsic scatter. Methods. As the SEDm is not designed as a spectrophotometric instrument, we first improved the flux-calibration accuracy of the SN Ia spectrum sample using the ZTF photometric data, which were calibrated at the percent level. We corrected the spectra for second-order polynomials, fitted by comparing the synthetic photometry in the ZTF g , r , i filters with the light-curve (LC) data. We then applied the three steps of the TE parameterization to a subset of 783 ZTF SN spectra near maximum light while comparing results from SNfactory and ZTF. We finally analyzed the standardization methods based on the TE parameters. Results. The precision of the phase-correction model, which is the first step of the TE, is estimated at 0.01 mag in g band based on ZTF data. Despite the challenge posed by the spectrum-extraction pipeline associated with the SEDm (flux calibration, leftover host signal, low signal-to-noise ratio, and low resolution), we applied a first standardization in color based on the second step of the TE, called read between the lines (RBTL), to the ZTF sample. We reached a Hubble residual scatter of 0.153 mag, all in normalized median absolute deviation, which is to be compared to the ∼0.11 mag obtained with the SNfactory data. The SALT color and stretch standardization reaches a scatter of 0.164 mag for the same ZTF SN Ia sample, and its host steps are ∼0.1 mag and zero for RBTL. When considering the scatter due to the redshift error and flux calibration error, we estimated a RBTL scatter of ∼0.129 mag for this ZTF sample as an upper limit because we identified an additional contribution from a systematic error in color. We tested the standardization based on the nonlinear TE parameters, and, as expected from the low spectrum quality, it did not improve the overall dispersion. Conclusions. We release 1897 flux calibrated spectra of 1607 SNe Ia with an estimated photometric accuracy of 0.07 mag. We further demonstrate that some amount of spectrophotometric SN Ia standardization can be done with limited-quality spectra. The RBTL standardization is more efficient than that of SALT with one parameter less, and the resulting host steps are consistent with zero. This makes it less prone to astrophysical bias. For future spectroscopic surveys, targeting the extraction pipeline for a thorough flux calibration and good signal-to-noise ratio would enable us to compute the full TE standardization, which would further reduce the scatter in the distance estimate.

Ganot, C↗

A device for volatile organic compound (VOC) analysis from skin using heated dynamic headspace sampling

Abstract Human skin is an important source of volatile organic compounds (VOCs) offering noninvasive methods to gain clinical metabolite information. This work was focused on the development of a skin sampling device based on a dynamic headspace sampling method with the addition of temperature to increase VOC metabolite recovery. The device preconcentrates skin VOC emissions onto a sorbent substrate, which can either be preserved for offline analysis or attached to a real time sensor downstream. In this work, skin VOC samples were analyzed offline using thermal desorption-gas chromatography-mass spectrometry. A list of 10 common skin VOCs was pre-selected to optimize parameters of sampling time, sampling temperature, and sorbent selection. Overall, this study highlights an effective skin VOC sampling technology with a heating dimension (40 °C, rather than 30 °C or no heating) with a sampling time of 15 min (rather than 5 or 30 mins) and onto Tenax TA sorbent (rather than PDMS), which collectively increases the recovery of compounds with lower vapor pressure and decreases the observed variability in skin VOC measurements. Finally, a list of 79 skin VOC compounds were detected and identified within a cohort of 20 young, healthy volunteers.

Biochemistry & Molecular Biology↗

Identifying Sample Provenance From SEM/EDS Automated Particle Analysis via Few-Shot Learning Coupled With Similarity Graph Clustering

Automated particle analysis (APA) provides a vast amount of compositional data via energy-dispersive X-ray spectroscopy along with size and shape data via scanning electron microscopy for individual particles in a sample. In many instances, APA data are leveraged to support identification of the source of a sample based on the detection of particles of a specific composition. Often, the particles that provide context make up a minuscule portion of the sample. Additionally, the interpretation of complex samples can be difficult due to the diversity of compositions both in the mixture and within a particle. In this work, we demonstrate a method to compute and cluster similarity graphs that describe inter-particle relationships within a sample using a multi-modal few-shot learning neural network. Here, as a proof-of-concept, we show that samples known to have been exposed to gunshot residue can be distinguished from samples occasionally mistaken for gunshot residue. Our workflow builds upon standard APA techniques and data processing methods to unveil additional information in a readily interpretable and quantitatively comparable format.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laminography as a tool for imaging large-size samples with high resolution

Despite the increased brilliance of the new generation synchrotron sources, there is still a challenge with high-resolution scanning of very thick and absorbing samples, such as a whole mouse brain stained with heavy elements, and, extending further, brains of primates. Samples are typically cut into smaller parts, to ensure a sufficient X-ray transmission, and scanned separately. Compared with the standard tomography setup where the sample would be cut into many pillars, the laminographic geometry operates with slab-shaped sections significantly reducing the number of sample parts to be prepared, the cutting damage and data stitching problems. In this work, a laminography pipeline for imaging large samples (>1 cm) at micrometre resolution is presented. The implementation includes a low-cost instrument setup installed at the 2-BM micro-CT beamline of the Advanced Photon Source. Additionally, sample mounting, scanning techniques, data stitching procedures, a fast reconstruction algorithm with low computational complexity, and accelerated reconstruction on multi-GPU systems for processing large-scale datasets are presented. The applicability of the whole laminography pipeline was demonstrated by imaging four sequential slabs throughout an entire mouse brain sample stained with osmium, in total generating approximately 12 TB of raw data for reconstruction.

47 OTHER INSTRUMENTATION↗

Fast HARDI Uncertainty Quantification and Visualization with Spherical Sampling

In this paper, we study uncertainty quantification and visualization of orientation distribution functions (ODF), which corresponds to the diffusion profile of high angular resolution diffusion imaging (HARDI) data. The shape inclusion probability (SIP) function is the state‐of‐the‐art method for capturing the uncertainty of ODF ensembles. The current method of computing the SIP function with a volumetric basis exhibits high computational and memory costs, which can be a bottleneck to integrating uncertainty into HARDI visualization techniques and tools. We propose a novel spherical sampling framework for faster computation of the SIP function with lower memory usage and increased accuracy. In particular, we propose direct extraction of SIP isosurfaces, which represent confidence intervals indicating spatial uncertainty of HARDI glyphs, by performing spherical sampling of ODFs. Our spherical sampling approach requires much less sampling than the state‐of‐the‐art volume sampling method, thus providing significantly enhanced performance, scalability, and the ability to perform implicit ray tracing. Our experiments demonstrate that the SIP isosurfaces extracted with our spherical sampling approach can achieve up to 8164× speedup, 37282× memory reduction, and 50.2% less SIP isosurface error compared to the classical volume sampling approach. We demonstrate the efficacy of our methods through experiments on synthetic and human‐brain HARDI datasets.

97 MATHEMATICS AND COMPUTING↗

Characterization Results for the October 2024 Tank Farm 3H Evaporator Overhead Sample

On an annual basis, Savannah River Mission Completion (SRMC) provides 2H and 3H evaporator overhead samples to Savannah River National Lab (SRNL) to be analyzed per Section 5.2 of the Effluent Treatment Project (ETP) Waste Compliance Plan (WCP) and the Waste Acceptance Criteria (WAC). This report presents characterization results for the October 2024 3H evaporator overhead sample. The sample was clear and colorless with no visible solids. The results provide measurements for cesium-137 (137Cs), strontium-90 (90Sr), and iodine-129 (129I) with the radionuclide concentration limits specified by the WAC. These analyses were performed in duplicate, and a summary of the analytical results for this 3H evaporator overhead sample includes the following: The measured cesium-137 activity in the 3H evaporator overhead sample averaged 6.72E+01 dpm/mL, (3.90E+00 %RSD), which is below the ETP WAC limit of 1.30E+03 dpm/mL. The strontium-90 activity in the 3H evaporator overhead sample averaged <2.72E+00 dpm/mL, which is below the ETP WAC limit of 1.76E+02 dpm/mL. The iodine-129 activity in the 3H evaporator overhead sample averaged <1.63E-01 dpm/mL, which is below the ETP WAC limit of 1.00E+00 dpm/mL.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization Results for the August 2025 Tank Farm 2H Evaporator Overhead Sample

On an annual basis, Savannah River Mission Completion (SRMC) provides 2H and 3H evaporator overhead samples to Savannah River National Lab (SRNL) to be analyzed per Section 5.2 of the Effluent Treatment Project (ETP) Waste Compliance Plan (WCP) and the Waste Acceptance Criteria (WAC). This report presents the average characterization results for the August 2025 2H evaporator overhead sample. The sample was clear and colorless with no visible solids. The results provide measurements for cesium-137 ( 137 Cs), strontium-90 ( 90 Sr), and iodine-129 ( 129 I) with the radionuclide concentration limits specified by the WAC. These analyses were performed in duplicate, and all three measured radionuclide concentrations were within ETP WAC limits. A summary of the analytical results for this 2H evaporator overhead sample includes the following: The measured cesium-137 activity in the 2H evaporator overhead sample averaged 3.02E+02 dpm/mL, which is below the ETP WAC limit of 1.30E+03 dpm/mL. The strontium-90 activity in the 2H evaporator overhead sample averaged 3.33E+00 dpm/mL, which is below the ETP WAC limit of 1.76E+02 dpm/mL. The iodine-129 activity in the 2H evaporator overhead sample averaged 1.20E-01 dpm/mL, which is below the ETP WAC limit of 1.00E+00 dpm/mL. Although the measurements for Cs-137 and Sr-90 are lower compared to previous years, the results remain within a similar range to past measurements and are well below the WAC limits. Iodine-129 indicates detectable results compared to previous years, which can be attributed to recent salt batch processing trending close to the WAC limit for saltstone production. However, these results are still below the ETP WAC limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cross-section SEM-EDS Analysis of Corroded 316 Steel Samples Using JEOL 6610 SEM

Comparison of SEM images obtained for samples 316H-1, 5, 7, and 10 revealed that samples 1 and 5 were subjected to more corrosion than the other two samples. Pores of an average of 1µm size were also observed scattered near the edge of each sample. Corrosion layer thickness was measured from edge of the corroded surface to the pore region. It was found that 316H-1 and 316H-5 had more corrosion damage with 82.40µm and 100µm respectively. Sample 316H-5 posed a challenge in measuring the corrosion layer thickness due to it breaking off from the parent sample during polishing. Samples 316H-7 and 316H-10 are less corroded with 26.57µm and 39.94µm thickness respectively.

36 - MATERIALS SCIENCE↗

AutoSAC-Automated Sample Activation Calculation on VULCAN

AutoSAC is an automated python program to conduct sample activation calculation immediately after neutron scattering experiment on VULCAN. AutoSAC takes account of sample dimensions, compositions, forms, sample environments, neutron beam configurations, neutron scattering history, and proton charged resolved beam power etc., and uses a simplified method to rapidly estimate the radioactivity at end of beam or after. It generates a draft report per sample and repository of radioactivity per measurement and provides feedback of current radioactivity and decay time back to a neutron proposal Slack channel to inform users immediately on sample handling. It also utilizes either the sample note field in EPICS or sample composition or thickness correction and takes slack prompt or command to conduct post-beam SAC by demand. The program can be shared to be used in other beamlines at spallation neutron source with modified instrument configurations including instrument specific characteristic beam fluxes.

An, Ke [Oak Ridge National Laboratory (ORNL), Oak ↗

Description of core samples returned by Apollo 12

Three core samples were collected by the Apollo 12 astronauts. Two are single cores, one of which (sample 12026) was collected close to the lunar module during the first extravehicular activity period and is 19.3 centimeters long. The second core (sample 12027) was collected at Sharp Crater during the second extravehicular activity period and is 17.4 centimeters long. The third sample is a double core (samples 12025 and 12028), which was collected near Halo Crater during the second extravehicular activity period. Unlike the other cores, the double-drive-tube core sample has complex layering with at least 10 clearly defined stratigraphic units. This core sample is approximately 41 centimeters long.

Lindsay, J. F.↗

Documentation of Apollo 15 samples

A catalog is presented of the documentation of Apollo 15 samples using photographs and verbal descriptions returned from the lunar surface. Almost all of the Apollo 15 samples were correlated with lunar surface photographs, descriptions, and traverse locations. Where possible, the lunar orientations of rock samples were reconstructed in the lunar receiving laboratory, using a collimated light source to reproduce illumination and shadow characteristics of the same samples shown in lunar photographs. In several cases, samples were not recognized in lunar surface photographs, and their approximate locations are known only by association with numbered sample bags used during their collection. Tables, photographs, and maps included in this report are designed to aid in the understanding of the lunar setting of the Apollo 15 samples.

Sutton, R. L.↗

Chemical composition of Apollo 15, 16, and 17 samples

The authors analyzed 22 Apollo 15 samples, 21 Apollo 16 samples, 4 Luna 20 samples, and 6 Apollo 17 samples for 26 to 30 major, minor, and trace elements by instrumental neutron activation analysis (INAA). Major attention is given to Apollo 16 results and recent Apollo 17 data. The roster of elements via INAA has been extended to include Nd, Ni, Ir, and Au in the Apollo 16 and 17 samples. The latter three elements are highly abundant in these samples. Sample preparation, activation conditions, and the detailed INAA analytical procedure are essentially the same as reported by Laul and Schmitt (1973).

Laul, J. C.↗

Digital redesign of continuous systems by matching of states at multiple sampling periods

This paper presents a method of digital approximation of a continuous-data system by the matching of states at multiple sampling periods. Two alternate methods are presented; one method samples the states every sampling period, and alters the forward and feedback gains, so as to match the states of the two systems at the end of N sampling periods. The second method requires the sampling of the states every N sampling periods, with the change of gains at each sampling period. An illustrative example using the one-axis dynamics of the Skylab Satellite is presented.

Yackel, R. A.↗

Stability of multirate sampled-data systems

Current adaptive sampling schemes that can be used in sampled-data systems with variable rate sampling does not guarantee the stability of the resulting closed-loop system. A study was undertaken with the objective of finding a stable control law for multirate sampled-data systems. The problem is formulated such that the sampling interval is selected from a set of fixed number of sample intervals. A necessary and sufficient condition under which these types of systems can be stabilized is given. For a certain subclass of these types of systems, a sampling selection algorithm is given which results in a stable closed-loop system.

Stanford, D. P.↗