Search NASA⌕ Search

SEARCH · Search NASA

Results for “software validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

SMATool: Strength of materials analysis toolkit

The study of the strength of materials is a cornerstone in material science and engineering, playing a critical role in shaping the progress and application of materials in diverse industrial sectors. The strength of a material is meticulously examined to understand the behavior of the material under different stress conditions and environments, thereby guiding material selection and structural design. Herein, we introduce the SMATool, a computational toolkit for the efficient calculation and analysis of material strength at both zero and finite temperatures for 3D, 2D, 1D, and tubular 2D-based nanostructures and nanotubes, as well as 1D nanoribbons. The toolkit is capable of calculating tensile, shear, ultimate, yield, and indentation (Vickers' hardness) strengths in various dimensions, as well as the energy storage capacity. We conducted several calculations both at zero and finite temperatures to validate the accuracy and reliability of the developed software. Here, the results show that the SMATool package provides accurate predictions that align with existing data on material strength. SMATool integrates seamlessly with widely used electronic structure codes like VASP and Quantum Espresso, providing a user-friendly interface catering to academic researchers and industry professionals.

36 MATERIALS SCIENCE↗

Data preservation at the Fermilab Tevatron

The Fermilab Tevatron collider's data-taking run ended in September 2011, yielding a dataset with rich scientific potential. The CDF and D0 experiments each have approximately 9 PB of collider and simulated data stored on tape. A large computing infrastructure consisting of tape storage, disk cache, and distributed grid computing for physics analysis with the Tevatron data is present at Fermilab. The Fermilab Run II data preservation project intends to keep this analysis capability sustained through the year 2020 and beyond. To achieve this goal, we have implemented a system that utilizes virtualization, automated validation, and migration to new standards in both software and data storage technology and leverages resources available from currently-running experiments at Fermilab. Lastly, these efforts have also provided useful lessons in ensuring long-term data access for numerous experiments, and enable high-quality scientific output for years to come.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Protocol to detect dilution cycles in chemostat experiments and estimate growth rate slopes with linear modeling with R software chemostat_regression

Chemostat growth chambers measure optical density over time and require manual calculation of growth rates. Here, we present chemostat_regression, R software that enables users to automatically identify chemostat cycles and estimate growth rate using a linear regression approach. We describe steps for creating requisite software environment(s), formatting input data, executing the software via command line/RStudio/R-Shiny, interpreting results, assessing the validity of results, and modifying input parameters.

59 BASIC BIOLOGICAL SCIENCES↗

Finite element analysis of an extended end-plate connection using the T-stub approach

Beam-to-column end-plate bolted connections are usually used as moment-resistant connections in steel framed structures. For this joint type, the deformability is governed by the deformation capacity of the column flange and end-plate under tension and elongation of the bolts. All these elements around the beam tension flange form the tension region of the joint, which can be modeled by means of equivalent T-stubs. In this paper a beam-to-column end-plate bolted connection is substituted with a T-stub of appropriate effective length and it is analyzed using the commercially available finite element software ABAQUS. The performance of the model is validated by comparing the behavior of the T-stub from the numerical simulation with the behavior of the connection as a whole. The moment-rotation curve of the T-stub obtained from the numerical simulation is compared with the behavior of the whole extended end-plate connection, obtained by numerical simulation, experimental tests and analytical approach.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modelling dust transport in DIII-D with DTOKS-Upgrade

Comprehensive upgrades to the dust transport code Dust in TOKamaks (DTOKS) that extend the plasma-dust interaction model are presented and compared with recent measurements of dust transport in DIII-D. Simulations incorporating variation in physical properties of graphite dust with temperature and size in a stationary plasma background suggest a substantial decrease in lifetimes due principally to thermal expansion. The trajectories of 53 dust grains identified from analysis of visible camera data taken across two similar shots were used to measure the dust particle velocity distributions. Dust tracks terminated mostly at the outer divertor strike point having a mean observation time of 2.1 ± 0.4 ms. Stochastic modelling of 200 graphite dust particles in the DIII-D tokamak performed with DTOKS-U using plasma simulations generated by OEDGE found similar behaviour, with particles ablating rapidly after acquiring a positive charge in the region close to the outer strike point, creating an acute source of neutral carbon atoms. The simulated mean lifetime, 11 ± 2 ms, showed approximate agreement with experimental observation when corrected by accounting for dust visibility and ignoring the longest trajectories 1.5 ± 0.2 ms. Synthetic diagnostic data generated from coupling the results of DTOKS-U with the visualisation software Calcam offers a powerful new tool for validation of simulations and predictive calculations of dust dynamics.

Physics↗

Comparison of steady-state analytical wake models implemented in wind farm analysis software

A common set of mathematical wind turbine wake models are implemented in a few, well-adopted computational tools for wind farm wake modelling. Although the referenced mathematical formulations are common, implementation details may lead to differences in results. This study presents a systematic comparison of the implementation of mathematical wake models in open source, Python-based wind turbine wake modelling software, and a set of the models are directly compared. Despite aligning only the mathematical model parameters and retaining the default computational model parameters, good agreement is found across most of the model implementations, and additional agreement is expected upon further parameters alignment.

17 WIND ENERGY↗

Data preservation at the Fermilab Tevatron

The Fermilab Tevatron collider's data-taking run ended in September 2011, yielding a dataset with rich scientific potential. The CDF and DO experiments each have nearly 9 PB of collider and simulated data stored on tape. A large computing infrastructure consisting of tape storage, disk cache, and distributed grid computing for physics analysis with the Tevatron data is present at Fermilab. The Fermilab Run II data preservation project intends to keep this analysis capability sustained through the year 2020 or beyond. To achieve this, we are implementing a system that utilizes virtualization, automated validation, and migration to new standards in both software and data storage technology as well as leveraging resources available from currently-running experiments at Fermilab. Furthermore, these efforts will provide useful lessons in ensuring long-term data access for numerous experiments throughout high-energy physics, and provide a roadmap for high-quality scientific output for years to come.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Open-Source Suite for Advanced Synchrophasor Analysis

The paper presents the results of the development of the open-source suite of applications for synchrophasor analysis. The suite includes several software tools for oscillation analysis, power plant model validation, and frequency response analysis using synchrophasor measurements. All tools are based on the common framework and data sources. The developed tools have been used by the Bonneville Power Administration and other utilities for synchrophasor analysis. The paper includes several use cases based on the actual system PMU data.

PMU, model validation, Oscillation Modes, Open Sou↗

SU-E-T-211: Induced Release of Nanocarrier Encapsulated Chemotherapeutic Drugs Using Proton Radiotherapy Beams

Purpose: The purpose of this work was to develop and validate an open source independent MU dose calculation software for S and S IMRT based in the algorithm proposed by Kung et.al. Methods: Treatment plans were done using Iplan v4.5 BrainLAB TPS and S and S IMRT modality. A 6MV photon beam produced by a Primus linear accelerator equipped with an Optifocus MLC was used. TPS dose calculation algorithms were pencil beam and Monte Carlo. 230 IMRT treatments plans were selected for the study. The software was written under MALTLAB environment. Treatment plans were imported by the software using RTP format. Field fluences were reconstructed adding all segments.The algorithm implemented in the software calculates the dose at a reference point as the sum of primary and scatter dose. The primary dose is obtained by masking the fluence map with a circle of radius 1cm. The scatter dose is obtained through a shaped ring mask around the previous circle with a thickness of 0.5cm; the rings are increased one after another with constant thickness until cover the entire map of influence. The dosimetric parameters Sc, Sp and TPR vary depending on radio, the transmission effect of the MLC, inverse square law and dose profile are used for the calculation. Results: The average difference between measured and independent calculated dose was 0.4% ± 2.2% [−6.8%, 6.4%]. For 91% of the studied plans the difference was less than 3%. The difference between the measured and TPS dose with pencilbeam algorithm was 2.6% ± 1.41% [−2.0%, 5.6%] and Monte Carlo algorithm was 0.4% ± 1.5% [−4.9%, 3.7%]. The differences obtained are comparable to that obtained with the ionization chamber and TPS. Conclusion: The developed software is suitable for use in S and S IMRT dose calculation. This application is open and can be downloading under request.

60 APPLIED LIFE SCIENCES↗

SU-E-T-348: Verification MU Calculation for Conformal Radiotherapy with Multileaf Collimator Using Report AAPM TG 114

Purpose: The purpose of this work was to develop and validate an open source independent MU dose calculation software for 3D conformal radiotherapy with multileaf high and low resolution according to the report of AAPM TG 11 Methods: Treatment plans were done using Iplan v4.5 BrainLAB TPS. A 6MV photon beam produced by Primus and Novalis linear accelerators equipped with an Optifocus MLC and HDMLC, respectively. TPS dose calculation algorithms were pencil beam and Monte Carlo. 1082 treatments plans were selected for the study. The algorithm was written in free and open source CodeBlocks C++ platform. Treatment plans were imported by the software using RTP format. Equivalent size field is obtained from the positions of the leaves; the effective depth of calculation can be introduced by TPS's dosimetry report or automatically calculated starting from SSD. The inverse square law is calculated by the 3D coordinates of the isocenter and normalization point of the treatment plan. The dosimetric parameters TPR, Sc, Sp and WF are linearly interpolated. Results: 1082 plans of both machines were analyzed. The average uncertainty between the TPS and the independent calculation was −0.43% ± 2.42% [−7.90%, 7.50%]. Specifically for the Primus the variation obtained was −0.85% ± 2.53% and for the Novalis 0.00% ± 2.23%. Data show that 94.8% of the cases the uncertainty was less than or equal to 5%, while 98.9% is less than or equal to 6%. Conclusion: The developed software is appropriate for use in calculation of UM. This software can be obtained upon request.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-519: Investigation of the CyberKnife MultiPlan Monte Carlo Dose Calculation Using EBT3 Film Absolute Dosimetry for Delivery in a Heterogeneous Thorax Phantom

Purpose To characterize the Cyberknife (CK) robotic system’s dosimetric accuracy of the delivery of MultiPlan’s Monte Carlo dose calculations using EBT3 radiochromic film inserted in a thorax phantom. Methods The CIRS XSight Lung Tracking (XLT) Phantom (model 10823) was used in this study with custom cut EBT3 film inserted in the horizontal (coronal) plane inside the lung tissue equivalent phantom. CK MultiPlan v3.5.3 with Monte Carlo dose calculation algorithm (1.5 mm grid size, 2% statistical uncertainty) was used to calculate a clinical plan for a 25-mm lung tumor lesion, as contoured by the physician, and then imported onto the XLT phantom CT. Using the same film batch, the net OD to dose calibration curve was obtained using CK with the 60 mm fixed cone by delivering 0– 800 cGy. The test films (n=3) were irradiated using 325 cGy to the prescription point. Films were scanned 48 hours after irradiation using an Epson v700 scanner (48 bits color scan, extracted red channel only, 96 dpi). Percent absolute dose and relative isodose distribution difference relative to the planned dose were quantified using an in-house QA software program. Multiplan Monte Carlo dose calculation was validated using RCF dosimetry (EBT3) and gamma index criteria of 3%/3mm and 2%/2mm for absolute dose and relative isodose distribution measurement comparisons. Results EBT3 film measurements of the patient plans calculated with Monte Carlo in MultiPlan resulted in an absolute dose passing rate of 99.6±0.4% for the Gamma Index of 3%/3mm, 10% dose threshold, and 95.6±4.4% for 2%/2mm, 10% threshold criteria. The measured central axis absolute dose was within 1.2% (329.0±2.5 cGy) of the Monte Carlo planned dose (325.0±6.5 cGy) for that same point. Conclusion MultiPlan’s Monte Carlo dose calculation was validated using the EBT3 film absolute dosimetry for delivery in a heterogeneous thorax phantom.

60 APPLIED LIFE SCIENCES↗

Technical Note: On the calculation of stopping-power ratio for stoichiometric calibration in proton therapy

Purpose: The quantitative effects of assumptions made in the calculation of stopping-power ratios (SPRs) are investigated, for stoichiometric CT calibration in proton therapy. The assumptions investigated include the use of the Bethe formula without correction terms, Bragg additivity, the choice of I-value for water, and the data source for elemental I-values. Methods: The predictions of the Bethe formula for SPR (no correction terms) were validated against more sophisticated calculations using the SRIM software package for 72 human tissues. A stoichiometric calibration was then performed at our hospital. SPR was calculated for the human tissues using either the assumption of simple Bragg additivity or the Seltzer-Berger rule (as used in ICRU Reports 37 and 49). In each case, the calculation was performed twice: First, by assuming the I-value of water was an experimentally based value of 78 eV (value proposed in Errata and Addenda for ICRU Report 73) and second, by recalculating the I-value theoretically. The discrepancy between predictions using ICRU elemental I-values and the commonly used tables of Janni was also investigated. Results: Errors due to neglecting the correction terms to the Bethe formula were calculated at less than 0.1% for biological tissues. Discrepancies greater than 1%, however, were estimated due to departures from simple Bragg additivity when a fixed I-value for water was imposed. When the I-value for water was calculated in a consistent manner to that for tissue, this disagreement was substantially reduced. The difference between SPR predictions when using Janni’s or ICRU tables for I-values was up to 1.6%. Experimental data used for materials of relevance to proton therapy suggest that the ICRU-derived values provide somewhat more accurate results (root-mean-square-error: 0.8% versus 1.6%). Conclusions: The conclusions from this study are that (1) the Bethe formula can be safely used for SPR calculations without correction terms; (2) simple Bragg additivity can be reasonably assumed for compound materials; (3) if simple Bragg additivity is assumed, then the I-value for water should be calculated in a consistent manner to that of the tissue of interest (rather than using an experimentally derived value); (4) the ICRU Report 37 I-values may provide a better agreement with experiment than Janni’s tables.

60 APPLIED LIFE SCIENCES↗

EM Algorithm for Mapping Quantitative Trait Loci in Multivalent Tetraploids

Multivalent tetraploids that include many plant species, such as potato, sugarcane, and rose, are of paramount importance to agricultural production and biological research. Quantitative trait locus (QTL) mapping in multivalent tetraploids is challenged by their unique cytogenetic properties, such as double reduction. We develop a statistical method for mapping multivalent tetraploid QTLs by considering these cytogenetic properties. This method is built in the mixture model-based framework and implemented with the EM algorithm. The method allows the simultaneous estimation of QTL positions, QTL effects, the chromosomal pairing factor, and the degree of double reduction as well as the assessment of the estimation precision of these parameters. We used simulated data to examine the statistical properties of the method and validate its utilization. The new method and its software will provide a useful tool for QTL mapping in multivalent tetraploids that undergo double reduction.

59 BASIC BIOLOGICAL SCIENCES↗

Reactor Subsystem Simulation for Nuclear Hybrid Energy Systems

Nuclear Hybrid Energy Systems (NHES) could be a key part of the solution to achieving energy security, may provide reliable power availability even with increasing renewable energy penetration into the power grid, and may allow repurposing excess electricity in times of low demand. Incorporating a fission-based power source in a multi-output system (electricity and process heat) can offer significant advantages over carbon-based production sources, such as coal or natural gas, including reduction in atmospheric carbon emissions. In an integrated multi-output system, thermal energy from the nuclear reactor subsystem can be diverted to industrial applications in times of low electricity demand. High temperature, high quality heat from advanced reactor designs might be used for hydrogen production or synthetic fuel production (coal-to-liquid or natural gas-to-liquid processes). Low temperature heat from advanced reactor designs or the current and future fleet of light water reactors (LWRs) might be applied to desalination processes or be stored for later use in low temperature ammonia or hydrocarbon-based thermal cycles. The NHES research team is currently developing a dynamic simulation of an integrated hybrid energy system. A detailed simulation of proposed NHES architectures will allow initial computational demonstration of a tightly coupled NHES to identify key reactor subsystem requirements, identify candidate reactor technologies for a hybrid system, and identify key challenges to operation of the coupled system. This work will provide a baseline for later coupling of design-specific reactor models through industry collaboration. The modeling capability addressed in this report focuses on the reactor subsystem simulation. Many computational tools and methods are available for modeling a nuclear reactor, power conversion systems and associated process applications. One method is to develop a single program capable of modeling the entire system. Another is to combine two or more existing computer programs, each modeling a portion of the system for which it is validated, where the programs exchange information to compute the solution. The former method requires a lengthy development and verification and validation process. The latter method leverages industry standard software to reduce development and funding requirements. Preliminary system models have been developed by Idaho National Laboratory researchers and are currently being enhanced to assess integrated system performance given multiple sources (e.g., nuclear + wind) and multiple applications (i.e., electricity + process heat). Initial efforts to integrate a Fortran-based simulation of a small modular reactor (SMR) with the balance of plant model have been completed in FY12. This initial effort takes advantage of an existing SMR model developed at North Carolina State University to provide initial integrated system simulation for a relatively low cost. The SMR subsystem simulation details are discussed in this report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Deep in Data: Empirical Data Based Software Accuracy Testing Using the Building America Field Data Repository

This paper describes progress toward developing a usable, standardized, empirical data-based software accuracy test suite using home energy consumption and building description data. Empirical data collected from around the United States have been translated into a uniform Home Performance Extensible Markup Language format that may enable software developers to create translators to their input schemes for efficient access to the data. This could allow for modeling many homes expediently, and thus implementing software accuracy test cases by applying the translated data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Geometric Scale-up Experiments on Fluidization of Geldart B Glass Beads

The objective of this work is to provide a valuable database from controlled experiments for validating computational models. Recently, coarse-grained techniques such as particle-in-cell (PIC) or coarse-grained discrete element modeling (DEM) have gained popularity due to their computational efficiency while modeling large-scale systems; however, the influence of model parameters and their sensitivities at different geometric scales and flow conditions remain to be analyzed. These datasets are critical for the multiphase flow research community to assess predictive capability of modeling techniques as well as elucidate the hydrodynamic behavior in these systems. This study performed fluidization experiments using three different test sections with internal diameters of 2.5, 4, and 6 in. The operating conditions, bed material, and range of flow velocities at the inlet were constant in all the units, which were not hydrodynamically scaled. Glass beads having a Sauter Mean Diameter of 332 μm were used. Superficial velocity was varied from 2.97 to 5.35 times the minimum fluidization velocity and the initial static bed height was 0.1524 m. The order in which the experiments were performed was randomized and replicates were included to provide uncertainty in measurements. Statistics of differential pressure and bed height from these tests were reported. Future plans include validating PIC methodology in the open-source software, MFiX (Multiphase Flow with Interphase Exchanges) using results from this study. This could further be extended to determine optimal model parameters using inverse techniques such as deterministic calibration or Bayesian inference.

20 FOSSIL-FUELED POWER PLANTS↗

Geometric Scale-up Experiments on Fluidization of Geldart B Glass Beads

The objective of this work is to provide a valuable database from controlled experiments for validating computational models. Recently, coarse-grained techniques such as particle-in-cell (PIC) or coarse-grained discrete element modeling (DEM) have gained popularity due to their computational efficiency while modeling large-scale systems; however, the influence of model parameters and their sensitivities at different geometric scales and flow conditions remain to be analyzed. These datasets are critical for the multiphase flow research community to assess predictive capability of modeling techniques as well as elucidate the hydrodynamic behavior in these systems. This study performed fluidization experiments using three different test sections with internal diameters of 2.5, 4, and 6 in. The operating conditions, bed material, and range of flow velocities at the inlet were constant in all the units, which were not hydrodynamically scaled. Glass beads having a Sauter Mean Diameter of 332 μm were used. Superficial velocity was varied from 2.97 to 5.35 times the minimum fluidization velocity and the initial static bed height was 0.1524 m. The order in which the experiments were performed was randomized and replicates were included to provide uncertainty in measurements. Statistics of differential pressure and bed height from these tests were reported. Future plans include validating PIC methodology in the open-source software, MFiX (Multiphase Flow with Interphase Exchanges) using results from this study. This could further be extended to determine optimal model parameters using inverse techniques such as deterministic calibration or Bayesian inference.

42 ENGINEERING↗

Open Source Suite for Advanced Synchrophasor Analysis

The report presents the results of the development of the open-source suite of applications for synchrophasor analysis. The suite includes several software tools for oscillation analysis, power plant model validation, and frequency response analysis using synchrophasor measurements. All tools are based on the common framework and data sources. The developed tools have been used by different electrical utilities for synchrophasor analysis. The report includes several use cases based on the actual system PMU data.

20 FOSSIL-FUELED POWER PLANTS↗