Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectral function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Spectral Spherical Harmonics Discrete Ordinate Method

A new method for modeling the radiative transfer in inhomogeneous three-dimensional media illuminated by a Gaussian beam is described. This approach, called the Spectral Spherical Harmonics Discrete Ordinate Method (SSHDOM), uses the Fourier expansion method to transform the three-dimensional radiative transfer into an one-dimensional equation in the spectral domain, and the Spherical Harmonics Discrete Ordinate Method (SHDOM) for its solution. Specifically, (i) the source function is represented in the spectral domain through a spherical harmonic expansion, (ii) the spectral one-dimensional radiative transfer equation is integrated along discrete ordinates through a spatial grid, and (iii) the solution method is based on the Picard iteration. Both SSHDOM and SHDOM algorithms are implemented in a common computer code.

Gaussian beam↗

The lunar conductivity profile and the nonuniqueness of electromagnetic data inversion.

A review of the theory for the electromagnetic functional used to date to determine the lunar conductivity profile from spectral analyses of lunar magnetometer data. The 'hard' boundary condition used by Sonett et al. (1971) and others appears to be a good approximation for the sunlit lunar hemisphere. The use of the spectral data in conjunction with the functional to find a least squares conductivity profile is examined from the point of view of the nonuniqueness of nonlinear estimation. An unsuccessful search was carried out to find models that were both geophysically reasonable and consistent with the data. It is asserted that the failure to find these models is due to the inadequacy of the functional. Of the models generated, those that best fit the data all have a conductivity peak at a depth of 240 km similar to that of the model discussed by Sonett et al. However, all of these models are quite distinct elsewhere in the profile. It is shown how such models are dependent on both the nature of the functional as well as the initial guess in the least squares procedure. A correlation analysis shows that the only resolvable features from this type of model are a low conductivity crust, a high conductivity peak of limited radial extent, and a low conductivity zone beneath the peak.

Phillips, R. J.↗

RXTE Observation of Cygnus X-1: TIming Analysis - Report 2

We present timing analysis for a Rossi X-ray Timing Explorer (RXTE) observation of Cygnus X-1 in its hard/low state. This was the first RXTE observation of Cyg X-1 taken after it transited back to this state from its soft/high state. RXTE's large effective area, superior timing capabilities, and ability to obtain long, uninterrupted observations have allowed us to obtain measurements of the power spectral density (PSD), coherence function, and Fourier time lags to a decade lower in frequency and half a decade higher in frequency than typically was achieved with previous instruments. Notable aspects of our observations include a weak 0.005 Hz feature in the PSD coincident with a coherence recovery; a 'hardening' of the high-frequency PSD with increasing energy; a broad frequency range measurement of the coherence function, revealing rollovers from unity coherence at both low and high frequency; and an accurate determination of the Fourier time lags over two and a half decades in frequency. As has been noted in previous similar observations, the time delay is approximately proportional to f(exp -0.7), and at a fixed Fourier frequency the time delay of the hard X-rays compared to the softest energy channel tends to increase logarithmically with energy. Curiously, the 0.01-0.2 Hz coherence between the highest and lowest energy bands is actually slightly greater than the coherence between the second highest and lowest energy bands. We carefully describe all of the analysis techniques used in this paper, and we make comparisons of the data to general theoretical expectations. In a companion paper, we make specific comparisons to a Compton corona model that we have successfully used to describe the energy spectral data from this observation.

Nowak, Michael A.↗

Quantifying Temperature Dependence of Pu(IV) Absorbance Spectra for Advanced Online Monitoring of Nuclear Processes

This article presents a systematic study of Pu(IV) absorbance spectral features as a function of temperature to develop an understanding of this parameter’s effect on chemometric models that can be used as online monitoring tools to support nuclear processing. The descriptive and predictive models that provide real-time feedback of these processes are usually constructed with data collected in conditions typical of a laboratory environment, which can differ drastically from a processing environment. To assess the impact of temperature on Pu(IV) absorbance spectra, 11 samples of Pu(IV) were synthesized with varying HNO 3 concentrations ranging from 0.6 to 9.5 M and heated between 15 and 45 °C. Ultraviolet (UV)–visible (vis)–near-infrared (NIR) absorption spectra collected at different HNO 3 concentrations and temperatures revealed that features associated with Pu(IV) are sensitive to temperature at all HNO 3 concentrations and that changes in features depend on HNO 3 concentration. The contributions of temperature and HNO 3 concentration to variation in Pu(IV) spectral features were evaluated using the principal component analysis of spectra that were baseline-corrected with an asymmetric least-squares method. Furthermore, predictive modeling for HNO 3 concentration with partial least-squares regression of UV–vis–NIR spectra highlighted the importance of accounting for temperature in the calibration set to optimize model performance. This methodology constitutes a new, systematic approach to account for the effect of temperature on the absorption spectra of metal ions and is useful for process monitoring applications in many industries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mechanistic insights into low-temperature oxidation of carbon fibers: Influence of hydrogen defects and crystallite size

Although oxidation mechanisms have been exhaustively studied for graphite, similar analyses of carbon fibers are comparatively sparse. Most prior work has focused on quantifying weight loss or assessing protective surface coatings designed to slow oxidation. The use of optical spectroscopic techniques for oxidation analyses is comparatively unexplored, but such techniques could provide an early indicator of fiber oxidation that would undermine carbon fiber performance. Here, in this work, we applied Raman spectroscopy to study oxidation-induced spectral alterations in 16 carbon fiber types from 7 manufacturers oxidized at 300 °C for 72 h, 400 °C for 8 h, and 500 °C for 1 h. We connect these results with structural properties of the carbon fibers obtained through wide-angle X-ray scattering, identifying a linear dependence between the reactivity of carbon fibers and the crystallite size of the unperturbed fibers. We then demonstrate that substituted hydrogen defects are likely removed from the fiber surface during oxidation and use the relative defect concentration to predict the Raman spectral change as a function of temperature and time, assuming Arrhenius behavior.

Carbon fiber↗

Near-Infrared Emission from Sulfur Heteroatom Defects in Single-Walled Carbon Nanotubes

Quantum defects introduced into single-walled carbon nanotubes (SWCNTs) that support near-infrared emission are promising candidates for many applications. Here, we present a type of quantum defect in which sulfur atoms are incorporated into the crystal lattice of SWCNTs through their reactions with a mild reducing agent, sodium dithionite. When radical anions generated by sodium dithionites react with (6,5)-SWCNTs, two new emission features emerge at 1120 and 1250 nm. Comparing these spectral features with density functional theory calculation results, we attribute them to defects with episulfide or thioether structures. Here, by investigating the influences of reaction conditions including reactant concentration, light irradiation, and solvent type, we identify the reaction mechanism between SWCNTs and sodium dithionite and achieve good control over defect densities. Due to the intrinsic reactivity of sulfur species, the sulfur-containing quantum defects discovered here may facilitate the introduction of more complex and functionally diverse moieties into SWCNTs.

Anions↗

Novel application of neutrinos to evaluate U.S. nuclear weapons performance

There is a growing realization that neutrinos can be used as a diagnostic tool to better understand the inner workings of a nuclear weapon. Robust estimates demonstrate that an Inverse Beta Decay (IBD) neutrino scintillation detector built at the Nevada Test Site with a 1000-ton active target mass at a standoff distance of 500 m would detect thousands of antineutrino events per nuclear test. This would provide less than 4% statistical error on the measured antineutrino rate and 5% error on antineutrino energy. Extrapolating this to an error on the test device explosive yield requires knowledge from evaluated nuclear databases, non-equilibrium fission rates, and assumptions on internal neutron fluxes. Initial calculations demonstrate that the total number of neutrinos emitted per fission in the first 10 3 s after a short pulse of 239 Pu fission is about a factor of two less than that from Pu fissioning under steady state conditions. Furthermore, there are significant energy spectral differences as a function of time after the pulse that must be considered. These and other model dependencies will be discussed in the paper. In the absence of nuclear weapons testing, many of the technical and theoretical challenges of a full nuclear test could be mitigated with a low cost smaller scale 20 ton fiducial mass IBD demonstration detector placed near a pulsed reactor. Potential reactors include the Texas A&M University TRIGA 1 GW–10 ms pulsed facility or the Sandia Annular Core Research Reactor. The short duty cycle and repeatability of pulses would provide critical real environment testing and measurements, which would be valuable for planning a possible real test shot in the future. Furthermore, the antineutrino rate as a function of time data would provide unique constraints on fission databases and model assumptions. Finally, there are impactful science drivers such as sensitive searches for ∼1 eV 2 sterile neutrinos and ∼MeV scale axions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spectrometer-free quantitative vapor sensing and classification via spatiotemporal imaging of porous silicon metasurfaces

Metasurfaces offer a compact platform for optical vapor sensing, but their practical deployment has been limited by weak evanescent light–matter interactions and reliance on spectrally resolved instrumentation. Here, we report porous silicon (pSi) metasurfaces for spectrometer-free quantitative detection of volatile organic compounds (VOCs) with strongly enhanced light–matter interaction. The engineered porosity increases sensitivity by >100× relative to non-porous dielectric metasurfaces, enabling limits of detection of 1.65 ppm for methanol and 9.1 ppm for ethanol across a broad dynamic range (<10 ppm to >103 ppm). Imaging-based readout provides a lightweight, spectrometer-free pathway for real-time quantitative sensing. Beyond quantitative detection, the mesoporous architecture introduces adsorption–desorption kinetics as an additional information channel. Analysis of the resulting spatiotemporal signatures enables kinetic fingerprinting without reliance on infrared spectral features or surface functionalization, and a lightweight machine-learning classifier differentiates acetone, methanol, ethanol, and isopropanol with 91.6% accuracy. These results establish porous metasurfaces as spatiotemporal sensing elements that couple quantitative vapor detection with kinetic fingerprinting through real-time dynamical responses, enabling low-cost, high-performance optical sensors.

Dash, Tomoshree [Clemson University]↗

Airborne spectrometer senses several gases

Spectrometer's variable shutter permits observation of a wide range of plume widths. Adjustable grating, counter, and access window enable operator to reset grating's position during flight by resetting the counter to a predetermined number. Quartz correlation mask and spectral-aperture instrument-function filter are mounted in a replaceable precision frame.

Mc Dowall, J.↗

Characteristics of cesium iodide for use as a particle discriminator for high energy cosmic rays

The possible use of CsI to discriminate between high energy cosmic ray electrons and interacting protons has been investigated. The pulse-shape properties as a function of ionization density, temperature, and spectral response are presented for thallium-activated CsI and as a function of ionization density for sodium-activated CsI. The results are based on previously published data and on corroborative measurements from the present work. Experimental results on the response of CsI to electron-induced electromagnetic cascades and to interacting hadrons are described. Bibliographies of publications dealing with the properties of CsI and with pulse-shape discrimination techniques are presented.

Crannell, C. J.↗

Nonstationary envelope process and first excursion probability.

The definition of stationary random envelope proposed by Cramer and Leadbetter, is extended to the envelope of nonstationary random process possessing evolutionary power spectral densities. The density function, the joint density function, the moment function, and the crossing rate of a level of the nonstationary envelope process are derived. Based on the envelope statistics, approximate solutions to the first excursion probability of nonstationary random processes are obtained. In particular, applications of the first excursion probability to the earthquake engineering problems are demonstrated in detail.

Yang, J.-N.↗

Scintillation statistics measured in an earth-space-earth retroreflector link

Scintillation was measured in a vertical path from a ground-based laser transmitter to the Geos 3 satellite and back to a ground-based receiver telescope and, the experimental results were compared with analytical results presented in a companion paper (Bufton, 1977). The normalized variance, the probability density function and the power spectral density of scintillation were all measured. Moments of the satellite scintillation data in terms of normalized variance were lower than expected. The power spectrum analysis suggests that there were scintillation components at frequencies higher than the 250 Hz bandwidth available in the experiment.

Bufton, J. L.↗

On the propagation of cosmic rays in the Galaxy

Cosmic ray propagation in the Galaxy is examined within the framework of the leaky-box model, whereby phenomenological aspects of diffusion and propagation are related to the physical properties of the interstellar medium. The model is parameterized by data on composition, spectra, spectral change as a function of energy, and cosmic ray particle lifetime. It is assumed that electrons and nucleons have a common source within the Galaxy (probably associated with supernova remnants). Lifetime data and leakage length are compared with radio synchrotron and gamma-ray data to establish a place of origin for cosmic rays observed at earth, i.e., at a radius of 0.5-1.0 kpc from earth. It is noted that if the escape length becomes energy independent, all nuclear spectra will flatten, while the electron spectrum remains unchanged.

Ormes, J.↗

The International Ultraviolet Explorer spectral image processing system

The International Ultraviolet Explorer spectral image processing system is an on-line interactive system which provides data on the UV spectra of astronomical objects in the wavelength range 1000 to 3200 A. In operation for one year, the image processing system accepts two-dimensional images transmitted digitally from the satellite's SEC vidicon cameras. The system extracts spectral intensity as a function of wavelength and removes background, scattered light, halation and echelle effects.

Klinglesmith, D. A., III↗

A structural model of the adaptive human pilot

A compensatory tracking model of the human pilot is offered which attempts to provide a more realistic representation of the human's signal processing structure than that which is exhibited by pilot models currently in use. Two features of the model distinguish it from other representations of the human pilot. First, proprioceptive information from the control stick or manipulator constitutes one of the major feedback paths in the model, providing feedback of vehicle output rate due to control activity. Implicit in this feedback loop is a model of the vehicle dynamics which is valid in and beyond the region of crossover. Second, error-rate information is continuously derived and independently but intermittently controlled. An output injected remnant model is offered and qualitatively justified on the basis of providing a measure of the effect of inaccuracies such as time variations in the pilot's internal model of the controlled element dynamics. The data from experimental tracking tasks involving five different controlled element dynamics and one nonideal viewing condition were matched with model generated describing functions and remnant power spectral densities.

Hess, R. A.↗