Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectral imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

James Clerk Maxwell Telescope Spectral and Continuum Imaging of Hyperactive Comet 46P/Wirtanen

The Jupiter-family comet (JFC) 46P/Wirtanen passed the Earth at a distance of 0.077 au on 2018 December 16 UT, presenting a rare opportunity to study the chemical structure of its coma. With the James Clerk Maxwell Telescope we achieved a resolution of 800 km, which is smaller than the scale lengths of some distributed cometary molecules at the comet’s heliocentric distance of 1 au. Spectroscopic observations of the J = 4 - 3 transition of HCN showed generally uniform levels of outgassing activity during the observing period, 2018 December 14–20. Gas expansion velocities were ~0.6 km s{sup -1}, and the derived average HCN production rate was 7.4 × 10{sup 24} mol s{sup -1}. HCN and CH{sub 3}OH emissions were detected at least 30" (1600 km) from the nucleus, and the abundances of these species were typical for a JFC. The radial distribution of CH{sub 3}OH is consistent with an extended source of sublimation such as a population of icy grains—cometary halo ice primaries, or CHIPs—as has been invoked previously to explain hyperactivity in comets. The abundance of H{sub 2}CO is normal if it is a daughter species. HNC and CO were not detected, but a sensitive nondetection of CS implies an unusually low CS:H{sub 2}O ratio of <0.02%. The peak brightness of the 850 μm continuum emissions from icy coma dust particles of size ~1 mm fell from (52 ± 6) to (40 ± 3) mJy beam{sup -1} through the week, while the size of the dust coma remained essentially constant, with dust extending to ~1000 km from the nucleus. The total mass of those particles was ~2 × 10{sup 8} kg.

79 ASTRONOMY AND ASTROPHYSICS↗

Probing the Capability of Future Direct-imaging Missions to Spectrally Constrain the Frequency of Earth-like Planets

A critical question in astrobiology is whether exo-Earth candidates (EECs) are Earth-like, in that they originate life that progressively oxygenates their atmospheres similarly to Earth. We propose answering this question statistically by searching for O{sub 2} and O{sub 3} on EECs with missions such as HabEx or LUVOIR. We explore the ability of these missions to constrain the fraction, f {sub E}, of EECs that are Earth-like in the event of a null detection of O{sub 2} or O{sub 3} on all observed EECs. We use the Planetary Spectrum Generator to simulate observations of EECs with O{sub 2} and O{sub 3} levels based on Earth’s history. We consider four instrument designs—LUVOIR-A (15 m), LUVOIR-B (8 m), HabEx with a starshade (4 m, “HabEx/SS”), and HabEx without a starshade (4 m, “HabEx/no-SS”)—as well as three estimates of the occurrence rate of EECs (η {sub earth}): 24%, 5%, and 0.5%. In the case of a null detection, we find that for η {sub earth} = 24%, LUVOIR-A, LUVOIR-B, and HabEx/SS would constrain f {sub E} to ≤0.094, ≤0.18, and ≤0.56, respectively. This also indicates that if f {sub E} is greater than these upper limits, we are likely to detect O{sub 3} on at least one EEC. Conversely, we find that HabEx/no-SS cannot constrain f {sub E}, due to the lack of a coronagraph ultraviolet channel. For η {sub earth} = 5%, only LUVOIR-A and LUVOIR-B would be able to constrain f {sub E}, to ≤0.45 and ≤0.85, respectively. For η {sub earth} = 0.5%, none of the missions would allow us to constrain f {sub E}, due to the low number of detectable EECs. We conclude that the ability to constrain f {sub E} is more robust to uncertainties in η {sub earth} for missions with larger aperture mirrors. However, all missions are susceptible to an inconclusive null detection if η {sub earth} is sufficiently low.

74 ATOMIC AND MOLECULAR PHYSICS↗

Cloud type separation by spectral differencing of image pairs

A technique is presented for discriminating different cloud types through an image subtraction of visible and infrared SMS/GOES picture pairs. The technique emphasizes how one could separate snow from clouds and identify cirrus by the subtraction method. Quantitative threshold values are shown which can be used in an objective manner to make this separation. Use is made of an all-digital image display device allowing such mathematical operations to be performed on satellite data. Techniques such as this can be made operational through the interfacing of the image analysis system with a direct-readout SMS/GOES ground station and distribution network.

Reynolds, D. W.↗

Summary of results and conclusions based on analysis of volume imaging and high spectral resolution lidar data acquired during FIRE phase 1, part 2

Since the fall of 1986, cirrus clouds were observed with backscatter cross sections ranging from less than 1 x 10(exp -7) to 4.2 x 10(exp -5)m/sr, optical thicknesses ranging from less than .003 to greater than 2.7, and bulk average backscatter phase functions from .02 to .065/sr. Cirrus cloud structures were recorded ranging in vertical extent from 0.1 to 8 km, having horizontal scales from 10's of meters to 266 km, and exhibiting aspect ratios of from 1:5 to 1:100. The altitude relationship between cloud top and bottom boundaries and the optical center of the cloud is influenced by the type of formation observed. Cirrus morphology and generation processes appear to be related to the wind field. The high spectral resolution lidar (HSRL) was adapted to the task of cirrus cloud optical property measurement. The HSRL data reported were collected with the CuCl2 transmitter producing 50 mW of output power, achieving eye safe, direct optical depth and backscatter cross section measurements with 10 minute averaging times.

Grund, Christian J.↗

Time-sequenced and spectrally filtered Rayleigh imaging of shock wave and boundary layer structure for inlet characterization

Multiple pulsed Rayleigh imaging and filtered Rayleigh scattering are used to generate images of a complex boundary layer structure, shock wave/boundary layer interactions, and crossing shock waves. Time-sequenced Rayleigh images taken with a visible, double-pulsed laser system show the evolution of boundary layer structure of the internal flow in a generic cross-shock inlet. The images taken in the inlet give insight into 3D effects caused by the inlet geometry and may be used for modeling the complex flows.

Forkey, Joseph↗

James Clerk Maxwell Telescope Spectral and Continuum Imaging of Hyperactive Comet 46P/Wirtanen

The Jupiter-family comet (JFC) 46P/Wirtanen passed the Earth at a distance of 0.077 au on 2018 December 16 UT, presenting a rare opportunity to study the chemical structure of its coma. With the James Clerk Maxwell Telescope we achieved a resolution of 800 km, which is smaller than the scale lengths of some distributed cometary molecules at the comet's heliocentric distance of 1 au. Spectroscopic observations of the J = 4 − 3 transition of HCN showed generally uniform levels of outgassing activity during the observing period, 2018 December 14–20. Gas expansion velocities were ~0.6 km s−1, and the derived average HCN production rate was 7.4 × 1024 mol s−1. HCN and CH3OH emissions were detected at least 30'' (1600 km) from the nucleus, and the abundances of these species were typical for a JFC. The radial distribution of CH3OH is consistent with an extended source of sublimation such as a population of icy grains—cometary halo ice primaries, or CHIPs—as has been invoked previously to explain hyperactivity in comets. The abundance of H2CO is normal if it is a daughter species. HNC and CO were not detected, but a sensitive nondetection of CS implies an unusually low CS:H2O ratio of <0.02%. The peak brightness of the 850 μm continuum emissions from icy coma dust particles of size ~1 mm fell from (52 ± 6) to (40 ± 3) mJy beam−1 through the week, while the size of the dust coma remained essentially constant, with dust extending to ~1000 km from the nucleus. The total mass of those particles was ~2 × 108 kg.

Ian M Coulson↗

Integrated and dynamic multi-spectroscopic in situ imaging of plant metabolism at the level of subcellular compartments. Final Report

The goals of this project was to develop integrated multi-spectral molecular imaging technologies (Raman, fluorescence, and mass spectrometry), that can assess, and image metabolic processes at the cellular and subcellular levels of plant organs. These imaging technologies were developed in the context of computational capabilities that integrated multi-spectral images with genome scale models of metabolism. The integrated molecular imaging technologies were developed in the biological context of autophagy that remodels membrane lipid topologies, which control spatially defined subcellular regions within plant cells and optimizes plant biomass productivity during environmental stresses that can limit biomass productivity.

09 BIOMASS FUELS↗

Multi-Angle Imager for Aerosols (MAIA) spectral and radiometric calibration

The Multi-angle Imaging SpectroRadiometer (MISR) was launched as part of NASA’s Terra satellite suite of instruments. Still operational, it makes use of observations from multiple view angles to retrieve aerosol abundance and particle properties. The Multi-Angle Imager for Aerosols (MAIA) instrument improves on this heritage by incorporating polarimetry and an expanded spectral range. Combining these data with surface measurements, the relationship between pollution and human health will be explored. MAIA has just completed camera testing, building on the experience from MISR. Spectral calibration now makes use of a double subtractive monochromator, built with the intent to allow the exit slit output to be uniform in spectral content. For radiometric testing, hardware upgrades have included adding UV lamps to the 1.65 cm (65") integrating sphere, use of a NIST-traceable sphere to establish absolute radiances, and the addition of a UV transfer spectrometer to support characterization of the sphere output from 300 to 2500 nm. During camera build, Newton’s rings were observed in the detector Quantum Efficiency (QE) measurements. This is due to etaloning within the detector itself. Etaloning was also evident in the spectral and radiometric characterizations performed on the completed camera. Spectral metrics, including center wavelength and width, are presented here using a moment’s analysis. This better represents the band properties, particularly in bands where fringing is observed, as compared to a full-width at half-maximum determination. It is believed that the MAIA camera has been carefully characterized, and meet its spectral and radiometric requirements.

Harten, Gerard Van↗

A Blind Convolutional Deep Autoencoder for Spectral Unmixing of Hyperspectral Images Over Waterbodies

Harmful algal blooms have dangerous repercussions for biodiversity, the ecosystem, and public health. Automatic identification based on remote sensing hyperspectral image analysis provides a valuable mechanism for extracting the spectral signatures of harmful algal blooms and their respective percentage in a region of interest. This paper proposes a new model called a non-symmetrical autoencoder for spectral unmixing to perform endmember extraction and fractional abundance estimation. The model is assessed in benchmark datasets, such as Jasper Ridge and Samson. Additionally, a case study of the HSI2 image acquired by NASA over Lake Erie in 2017 is conducted for extracting optical water types. The results using the proposed model for the benchmark datasets improve unmixing performance, as indicated by the spectral angle distance compared to five baseline algorithms. Improved results were obtained for various metrics. In the Samson dataset, the proposed model outperformed other methods for water (0.060) and soil (0.025) endmember extraction. Moreover, the proposed method exhibited superior performance in terms of mean spectral angle distance compared to the other five baseline algorithms. The non-symmetrical autoencoder for the spectral unmixing approach achieved better results for abundance map estimation, with a root mean square error of 0.091 for water and 0.187 for soil, compared to the ground truth. For the Jasper Ridge dataset, the non-symmetrical autoencoder for the spectral unmixing model excelled in the tree (0.039) and road (0.068) endmember extraction and also demonstrated improved results for water abundance maps (0.1121). The proposed model can identify the presence of chlorophyll-a in waterbodies. Chlorophyll-a is an essential indicator of the presence of the different concentrations of macrophytes and cyanobacteria. The non-symmetrical autoencoder for spectral unmixing achieves a value of 0.307 for the spectral angle distance metric compared to a reference ground truth spectral signature of chlorophyll-a. The source code for the proposed model, as implemented in this manuscript, can be found at https://github.com/EstefaniaAlfaro/autoencoder_owt_spectral.git.

hyperspectral imaging↗

Spectrally Resolved Synthetic Aperture Imaging Interferometer: Final Report of NASA Innovative Advanced Concepts - Phase 1 Study

The Spectrally Resolved Synthetic-Aperture Imaging Interferometer (SRSAII) is a system proposed to provide high-resolution and high-sensitivity measurements of astronomical objects. SRSAII uses long baseline interferometric methods to achieve the resolution and low-noise, high time-precision detection to achieve the sensitivity. The primary goal of the SRSAII study was to lay out a framework for using new optical physics technologies to directly resolve, both spatially and spectrally, the disk of an exoplanet. In addition to the ambitious goal of directly resolving an exoplanet, the SRSAII team also sought to identify science opportunities achievable with intermediate system configurations which may offer resolution significantly higher than the current state of the art, but insufficient for direct resolution of an exoplanetary disk. An operational SRSAII system can function with essentially arbitrarily large baselines, achieving correspondingly high angular resolution. The primary limitation occurs in the system sensitivity, which became the major technical focus for study. In this report, we compare the predicted performance (sensitivity in SNR (Signal-to-Noise Ratio) along with angular resolution) of three interferometric techniques: direct detection (also known as homodyne interferometry), multi-channel intensity interferometry (using the Hanbury Brown and Twiss effect), and multi-channel heterodyne interferometry (using an optical frequency comb as a local oscillator). Additionally, quantum-assisted interferometry is also explored as a prospective enhancement of established methods. This report presents a survey of the technologies that enable the SRSAII techniques - optical frequency combs, single photon detectors, and photonic integrated circuits. These technologies are the basis of methods critical to SRSAII's success: precision timing, length and frequency metrology, sensitive photodetection, fine-scale wavelength filtering, and dense multi-channel operation. Lastly, we give some notional performance metrics and propose some possible experimental observations.

High Resolultion↗

Spectral identification of minerals using imaging spectrometry data: Evaluating the effects of signal to noise and spectral resolution using the tricorder algorithm

The rapid development of sophisticated imaging spectrometers and resulting flood of imaging spectrometry data has prompted a rapid parallel development of spectral-information extraction technology. Even though these extraction techniques have evolved along different lines (band-shape fitting, endmember unmixing, near-infrared analysis, neural-network fitting, and expert systems to name a few), all are limited by the spectrometer's signal to noise (S/N) and spectral resolution in producing useful information. This study grew from a need to quantitatively determine what effects these parameters have on our ability to differentiate between mineral absorption features using a band-shape fitting algorithm. We chose to evaluate the AVIRIS, HYDICE, MIVIS, GERIS, VIMS, NIMS, and ASTER instruments because they collect data over wide S/N and spectral-resolution ranges. The study evaluates the performance of the Tricorder algorithm, in differentiating between mineral spectra in the 0.4-2.5 micrometer spectral region. The strength of the Tricorder algorithm is in its ability to produce an easily understood comparison of band shape that can concentrate on small relevant portions of the spectra, giving it an advantage over most unmixing schemes, and in that it need not spend large amounts of time reoptimizing each time a new mineral component is added to its reference library, as is the case with neural-network schemes. We believe the flexibility of the Tricorder algorithm is unparalleled among spectral-extraction techniques and that the results from this study, although dealing with minerals, will have direct applications to spectral identification in other disciplines.

Swayze, Gregg A.↗

ASCA observations of supernova remnants

The combined spectral and imaging capabilities of the Advanced Satellite for Cosmology and Astrophysics (ASCA) provides new possibilities for studying supernova remnants. The most powerful of these are spatially resolved, moderate resolution spectroscopy and narrowband spectral imaging. The use of these techniques yielded a number of results that challenge the currently held views on X-ray emission processes in supernova remnants. Evidence was found for the plasmas in which a different ionization timescale must be used to characterize each metal. Some recent findings from supernova remnant surveys conducted using ASCA are presented.

Petre, R.↗

Hyperspectral Infrared Imaging of Flames Using a Spectrally Scanning Fabry-Perot Filter

The temperatures and compositions of gases in and around flames can be diagnosed using infrared emission spectroscopy to observe molecular band shapes and intensities. We have combined this approach with a low-order scanning Fabry-Perot filter and an infrared camera to obtain spectrally scanned infrared emission images of a laboratory flame and exhaust plume from 3.7 to 5.0 micrometers, at a spectral resolution of 0.043 micrometers, and a spatial resolution of 1 mm. The scanning filter or AIRIS (Adaptive Infrared Imaging Spectroradiometer) is a Fabry-Perot etalon operating in low order (mirror spacing = wavelength) such that the central spot, containing a monochromatic image of the scene, is viewed by the detector array. The detection system is a 128 x 128 liquid-nitrogen-cooled InSb focal plane array. The field of view is controlled by a 50 mm focal length multielement lens and an V4.8 aperture, resulting in an image 6.4 x 6.4 cm in extent at the flame and a depth of field of approximately 4 cm. Hyperspectral images above a laboratory CH4/air flame show primarily the strong emission from CO2 at 4.3 micrometers, and weaker emissions from CO and H2O. We discuss techniques to analyze the spectra, and plans to use this instrument in microgravity flame spread experiments.

Rawlins, W. T.↗

Estimation of spectral reflectance curves from multispectral image data

A technique is presented for estimating spectral reflectance curves from multispectral image data even if the spectral samples are obtained from channels whose spectral responsivity is not narrowband. It is demonstrated that these reflectance estimates can be written as a linear combination of the spectral samples and that, analogous to Shannon's sampling theorem, if the spectral reflectance is a natural cubic spline, it can be estimated exactly provided the number of spectral channels is sufficiently large. Simulation results suggest that the accuracy of the spectral reflectance estimates is quite good and very insensitive to the spectral responsivity shapes.

Park, S. K.↗