Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectrum analyzers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

On attaining lower sidelobes and new antenna envelopes for better orbit spectrum utilization in satellite broadcasting

The concept of using beam-shaping techniques to reduce sidelobe levels at the expense of efficiency is introduced and analyzed with respect to the potential for improving orbit-spectrum utilization. Emphasis is placed on a simple method: improving the antenna patterns used in satellite systems, for both the satellite antennas and the ground station antennas. Only broadcasting applications are considered. The discussion includes how the antenna envelope can be improved, how this improvement can be interpreted in terms of orbit spectrum utilization efficiency, and whether this improved envelope is actually realizable and feasible. It is noted that the magnitude of the improvement with a better spacecraft antenna increases rapidly as the coverage area decreases.

Janky, J. M.↗

Candidate Core Designs for the Transformational Challenge Reactor

Early cycle activities under the Transformational Challenge Reactor (TCR) program focused on analyzing and maturing four reactor core design concepts: two fast-spectrum systems and two thermal-spectrum systems. A rapid, iterative approach has been implemented through which designs can be modified and analyzed and subcomponents can be manufactured in parallel over time frames of weeks rather than months or years. To meet key program initiatives (e.g., timeline, material use), several constraints—including fissile material availability (less than 250 kg of HALEU), component availabilities, materials compatibility, and additive manufacturing capabilities—were factored into the design effort, yielding small (less than one cubic meter in volume) cores with near-term viability. The fast-spectrum designs did not meet the fissile material constraint, so the thermal-spectrum systems became the primary design focus. Since significant progress has been made on advanced moderator materials (YH x ) under the TCR program, gas-cooled thermal-spectrum systems using less than 250 kg of HALEU that occupy less than 1 m 3 are now feasible. The designs for two of these systems have been evolved and matured. In both thermal-spectrum design concepts, bidirectional coolant flow is used. Coolant flows down through YH x moderator elements and is reversed in a bottom manifold and core support structure, and then flows up though or around the fuel elements. The main difference between the two thermal-spectrum design concepts is the fuel elements—one uses traditional UO 2 ceramic fuel, and the other uses UN-bearing TRISO fuel particles embedded inside a SiC matrix. Finally, core neutronics and thermal performance for these systems are assessed and summarized herein.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Using occupant interaction with advanced lighting systems to understand opportunities for energy optimization: Control data from a hospital NICU

For this study, lighting system control data from five patient rooms in a neonatal intensive care unit (NICU) over a 25-week monitoring period were analyzed to better understand how the NICU staff and families interacted with an automatic tunable lighting system (variable spectrum and intensity) with manual override options. The data were analyzed to determine the amount of time spent in available lighting modes, estimate energy consumption, and to observe any patterns in how the lighting system was being used by occupants. Further analysis revealed opportunities for optimizing the system for occupant needs and energy savings. The patient room occupants were clearly engaged in using the lighting system throughout the 24-hour day to meet needs and preferences. Giving occupants control over the lighting system did not result in a considerable increase in energy use. Implementing a time-out would minimize the extended periods of time when the lights were left on without need at the highest brightness level, further decreasing energy use. This analysis reveals the potential of lighting control data to contribute to energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of interferential correlation of spectrum to the detection of atmospheric pollutants

The general correlation principles for spectra and spectra derivatives are studied by using the Fourier transform of the spectral distribution of energy from a source illuminating a double beam interferometer with transverse splitting by dividing luminance. In this correlation technique, the use of such an interferometer has the advantage of greater luminosity as compared with a slit spectrometer. However, the correlation example indicates that it is necessary to adapt the correlator to the particular case considered, in order to obtain the best gain in the signal to noise ratio. In the case of sulfur dioxide detection, a very simple mounting which could be used in some interesting industrial applications was developed. This mounting can be used each time that the substance to be analyzed has a quasi-periodic absorption spectrum: in particular this is often the case with absorption spectra of gases, and a mounting identical to the one described for sulfur dioxide proved to be effective in the detection of nitrogen oxides.

Fortunato, G.↗

Cometary particulate analyzer design definition study

A concept for remotely determining the relative abundance of elements contained in cometary particulates collected by a spacecraft was conducted with very encouraging results. The technique utilizes a short high intensity burst of laser radiation to vaporize and ionize collected particulate material. Ions extracted from this laser-produced plasma are analyzed in a time of flight mass spectrometer to yield an atomic mass spectrum representative of the relative abundance of elements in the particulates. A prototype analyzer system was designed, constructed, and tested. Results show that: (1) energy-time focus performs as predicted in improving resolution; (2) power densities sufficient to produce usable ionization efficiencies can be obtained; (3) complex alloys such as stainless steel can be analyzed; and (4) a tiny, simple and reliable laser used in the demonstration easily meets spacecraft power and mass limitations. A mass resolution of 150 was experimentally demonstrated at mass 108, and an analytical extrapolation predicts a resolution sufficient to separate masses 250 and 251.

Utterback, N. G.↗

Remote Raman Sensor System for Testing of Rocks and Minerals

Recent and future explorations of Mars and lunar surfaces through rovers and landers have spawned great interest in developing an instrument that can perform in-situ analysis of minerals on planetary surfaces. Several research groups have anticipated that for such analysis, Raman spectroscopy is the best suited technique because it can unambiguously provide the composition and structure of a material. A remote pulsed Raman spectroscopy system for analyzing minerals was demonstrated at NASA Langley Research Center in collaboration with the University of Hawaii. This system utilizes a 532 nm pulsed laser as an excitation wavelength, and a telescope with a 4-inch aperture for collecting backscattered radiation. A spectrograph equipped with a super notch filter for attenuating Rayleigh scattering is used to analyze the scattered signal. To form the Raman spectrum, the spectrograph utilizes a holographic transmission grating that simultaneously disperses two spectral tracks on the detector for increased spectral range. The spectrum is recorded on an intensified charge-coupled device (ICCD) camera system, which provides high gain to allow detection of inherently weak Stokes lines. To evaluate the performance of the system, Raman standards such as calcite and naphthalene are analyzed. Several sets of rock and gemstone samples obtained from Ward s Natural Science are tested using the Raman spectroscopy system. In addition, Raman spectra of combustible substances such acetone and isopropanol are also obtained. Results obtained from those samples and combustible substances are presented.

Garcia, Christopher S.↗

Dynamic substructuring for shock spectrum analysis using component mode synthesis

Component mode synthesis was used to analyze different types of structures with MSC NASTRAN. The theory and technique of using Multipoint Constraint Equations (MPCs) to connect substructures to each other or to a common foundation is presented. Computation of the dynamic response of the system from shack spectrum inputs was automated using the DMAP programming language of the MSC NASTRAN finite element code.

Mcpheeters, Barton W.↗

Constraint of pionless EFT using two-nucleon spectra from lattice QCD

Finite-volume pionless effective field theory (FVEFT π/ ) at next-to-leading order (NLO) is used to analyze the two-nucleon lattice QCD spectrum of Ref. [1], performed at quark masses corresponding to a pion mass of approximately 800 MeV. Specifically, the effective theory is formulated in finite volume, and variational sets of wave functions are optimized using differential programming. Using these wave functions projected to the appropriate finite-volume symmetry group, variational bounds from FVEFT π/ are obtained for the ground state, as well as excited states. By comparison with the lattice QCD GEVP spectrum, different low energy constants (LECs) are constrained. Furthermore, relativistic corrections are incorporated, allowing for the s-d-wave mixing term in the deuteron channel.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for neutron decay into an antineutrino and a neutral kaon in 0.401 megaton-years exposure of Super-Kamiokande

We searched for bound neutron decay via 𝑛 → $\bar{𝜈}$ +𝐾 0 predicted by the grand unified theories in 0.401 Mton·years exposure of all pure water phases in the Super-Kamiokande detector. About 4.4 times more data than in the previous search have been analyzed by a new method including a spectrum fit to kaon invariant mass distributions. No significant data excess has been observed in the signal regions. As a result of this analysis, we set a lower limit of 7.8 × 10 32 years on the neutron lifetime at a 90% confidence level.

Cherenkov detectors↗

Enabling Ultralow Volume Analysis with a High-Resolution Ion Mobility Mass Spectrometry Platform

Of all the molecules thought to exist in the universe, it is estimated that researchers only know the chemical structures of 5% of them. Identifying the chemical structures of the remaining 95% has proven extremely challenging because many molecules exhibit low abundance, are contained in small volumes (e.g., <10 nL), do not readily ionize, exhibit similar structures to other molecules, etc. No single analytical technique exists to definitively identify the structure of an unknown molecule, and thus multiple different molecular measurements are typically made (i.e., multi-modal approach). Ion mobility (IMS) and mass spectrometry (MS) are two key tools that researchers use to determine the chemical structures of unknown molecules, and recently high-resolution and ultrahigh resolution IMS-MS instruments have provided greater confidence than ever before. However, HR-IMS-MS instruments typically exhibit low ion utilization efficiency, meaning they require large amounts of sample for an analysis (e.g., >10 µL). Unfortunately, this limitation prohibits the analysis of small volume samples where many unknown molecules exist. Described herein are the efforts made to enable the analysis of ultralow volumes with an HR-IMS-MS platform. A new scanning technique, termed a ‘stuttered traveling wave scan’, was developed as a replacement for the dual-gated scanning technique and works by halting the traveling waves after allowing ions to separate and then repeatedly restarting and stopping the traveling waves to incrementally move ions from the SLIM to the Orbitrap. Ions were stored inside the SLIM while the TWs were stopped, allowing the Orbitrap to perform high-resolution mass analysis. When the Orbitrap was ready, the TWs were restarted for short periods of time (<10 ms) to move ions from the SLIM to the Orbitrap. It was discovered that lower TW amplitudes and speeds than used during IMS separation were required to produce IMS peaks with the highest signal intensities and best resolving powers. The stuttered TW scan was found to produce similar resolutions and signal intensities compared to the dual-gated scanning technique. A new IMS design possessing an intersecting ‘tee’ with a reversible traveling wave was also developed to improve ion utilization efficiency during cyclic operation, which is necessary when only a single IMS spectrum can be acquired, such as when analyzing ultralow volume samples. The new capabilities described in this report lay the groundwork for acquiring HR-IMS-MS spectra of ultralow volume biological samples, such as single cells, where HR-IMS-MS can help elucidate the structures of unknown compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Manufacturing Bulk Nanocrystalline Al-3Mg Components Using Cryomilling and Spark Plasma Sintering

In the current study, pure aluminum (Al) powders were cryomilled with and without 3 wt.% pure magnesium (Mg) dopant for varying durations followed by spark plasma sintering (SPS) of powders to prepare bulk components with superior mechanical properties. The crystallite sizes were determined for powders and the bulk components by analyzing the X-ray diffraction (XRD) spectrum. The calculations indicated a reduction in crystallite size with the increase in the cryomilling duration. The results also showed a more significant decrease in the crystallite sizes for Al-3Mg samples than that of pure Al. The changes in the surface morphology of powders were characterized using scanning electron microscopy (SEM). The elemental mapping analysis at nanoscale was carried out using Energy-dispersive X-ray spectroscopy (EDX) in Scanning transmission electron microscopy (STEM). The mechanical properties of the bulk components were assessed using a Vickers Microhardness tester. The test results demonstrated an improvement in the hardness of Mg-doped components. Higher hardness values were also reported with an increase in the cryomilling duration. This article discusses the mechanisms for the reduction in crystallite size for pure Al and Al-3Mg and its subsequent impact on improving mechanical properties.

36 MATERIALS SCIENCE↗

The spectrum of N IV.

Spectrum of three-times ionized nitrogen analyzed in wavelength region 300-8000 angstroms, using theta pinch discharge, connecting singlets and triplets

IONIZED GAS↗

Uranium plasma radiates in the UV spectrum

Description of an experiment designed to produce and spectroscopically analyze a simulated gas core reactor plasma in the spectral range from 300 to 1300 A. The plasma was produced by focusing the radiation of a Q-spoiled ruby laser onto the flat surface of a pure U-238 specimen.

Williams, M. D.↗

Field aligned currents and the auroral spectrum below 1 keV

Measurements during auroral events were conducted with the aid of detectors flown aboard three Nike-Tomahawk rocket flights. The detectors used to measure the auroral spectrum below 1 keV consisted of electrostatic analyzers positioned in the rocket to measure particles moving up and down the magnetic field lines. The analyzers measured electrons and protons simultaneously during a given sweep.

Arnoldy, R. L.↗

Effort of spanwise variation of turbulence on the normal acceleration of airplanes with small span relative to turbulence scale

A rigid airplane with an unswept wing is analyzed. The results show that the power spectrum, relative to that for a one-dimensional turbulence field, is significantly attenuated at the higher frequencies even for airplanes with arbitrarily small ratios of span to scale of turbulence. This attenuation is described by a simple weighting function of frequency that depends only on aspect ratio. The weighting function, together with the attenuation due to the unsteady flow of gust penetration, allows the determination of the average rate of zero crossings for airplanes having very small spans without recourse to an integral truncation which is often required in calculations based on a one-dimensional turbulence field.

Pratt, K. G.↗

Interpretation of Beta Lyrae. III - A study of the disk around the secondary component

Light curves of Beta Lyrae available in the far-ultraviolet, visual, and infrared regions of the spectrum at numerous phases in eclipse are analyzed in order to investigate the physical and radiative nature of the disk surrounding the secondary component. The results of this analysis together with those of other investigators lead to the proposal that the outer regions of the disk are dominated by free electrons. This electron-scattering envelope is most likely the source of infrared radiation as well as the cause of the observed polarization. However, the radiation in the region from the optical to the far-ultraviolet comes mainly from submerged layers where local thermodynamic equilibrium prevails. These layers represent the photosphere of either the disk or the secondary component itself.

Brown, D. A.↗

The abundance of acetylene in the atmosphere of Jupiter

The Q and R branches of the C2H2 nu(5) fundamental, observed in emission in an aircraft spectrum of Jupiter near 750/cm, have been analyzed with the help of an improved line listing for this band. The line parameters have been certified in the laboratory with the same interferometer used in the Jovian observations. The maximum mixing ratio of C2H2 is found to be between 5 times 10 to the -8th and 6 times 10 to the -9th power, depending on the form of its vertical distribution and the temperature structure assumed for the lower stratosphere. Most consistent with observations of both Q and R branches are: (1) distributions of C2H2 with a constant mixing ratio in the stratosphere and a cutoff at a total pressure of 100 mbar or less, and (2) the assumption of a temperature at 0.01 bar which is near 155 K.

Orton, G. S.↗

A rocket-borne data-manipulation experiment using a microprocessor

The development of a data-manipulation experiment using a Z-80 microprocessor is described. The instrumentation is included in the payloads of two Nike Apache sounding rockets used in an investigation of energetic particle fluxes. The data from an array of solid-state detectors and an electrostatic analyzer is processed to give the energy spectrum as a function of pitch angle. The experiment performed well in its first flight test: Nike Apache 14.543 was launched from Wallops Island at 2315 EST on 19 June 1978. The system was designed to be easily adaptable to other data-manipulation requirements and some suggestions for further development are included.

Davis, L. L.↗