Search NASA⌕ Search

SEARCH · Search NASA

Results for “static testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

FACET Tolerances for Static and Dynamic Misalignments

The Facility for AdvancedAccelerator and Experimental Tests (FACET) at the SLAC National Accelerator Laboratory is designed to deliver a beam with a transverse spot size on the order of 10 {micro}m x 10 {micro}m in a new beamline constructed at the two kilometer point of the SLAC linac. Commissioning the beamline requires mitigating alignment errors and their effects, which can be significant and result in spot sizes orders of magnitude larger. Sextupole and quadrupole alignment errors in particular can introduce errors in focusing, steering, and dispersion which can result in spot size growth, beta mismatch, and waist movement. Alignment errors due to static misalignments, mechanical jitter, energy jitter, and other physical processes can be analyzed to determine the level of accuracy and precision that the beamline requires. It is important to recognize these effects and their tolerances in order to deliver a beam as designed.

43 PARTICLE ACCELERATORS↗

Multileaf collimator performance monitoring and improvement using semiautomated quality control testing and statistical process control

Purpose: High-quality radiation therapy using highly conformal dose distributions and image-guided techniques requires optimum machine delivery performance. In this work, a monitoring system for multileaf collimator (MLC) performance, integrating semiautomated MLC quality control (QC) tests and statistical process control tools, was developed. The MLC performance monitoring system was used for almost a year on two commercially available MLC models. Control charts were used to establish MLC performance and assess test frequency required to achieve a given level of performance. MLC-related interlocks and servicing events were recorded during the monitoring period and were investigated as indicators of MLC performance variations. Methods: The QC test developed as part of the MLC performance monitoring system uses 2D megavoltage images (acquired using an electronic portal imaging device) of 23 fields to determine the location of the leaves with respect to the radiation isocenter. The precision of the MLC performance monitoring QC test and the MLC itself was assessed by detecting the MLC leaf positions on 127 megavoltage images of a static field. After initial calibration, the MLC performance monitoring QC test was performed 3–4 times/week over a period of 10–11 months to monitor positional accuracy of individual leaves for two different MLC models. Analysis of test results was performed using individuals control charts per leaf with control limits computed based on the measurements as well as two sets of specifications of ±0.5 and ±1 mm. Out-of-specification and out-of-control leaves were automatically flagged by the monitoring system and reviewed monthly by physicists. MLC-related interlocks reported by the linear accelerator and servicing events were recorded to help identify potential causes of nonrandom MLC leaf positioning variations. Results: The precision of the MLC performance monitoring QC test and the MLC itself was within ±0.22 mm for most MLC leaves and the majority of the apparent leaf motion was attributed to beam spot displacements between irradiations. The MLC QC test was performed 193 and 162 times over the monitoring period for the studied units and recalibration had to be repeated up to three times on one of these units. For both units, rate of MLC interlocks was moderately associated with MLC servicing events. The strongest association with the MLC performance was observed between the MLC servicing events and the total number of out-of-control leaves. The average elapsed time for which the number of out-of-specification or out-of-control leaves was within a given performance threshold was computed and used to assess adequacy of MLC test frequency. Conclusions: A MLC performance monitoring system has been developed and implemented to acquire high-quality QC data at high frequency. This is enabled by the relatively short acquisition time for the images and automatic image analysis. The monitoring system was also used to record and track the rate of MLC-related interlocks and servicing events. MLC performances for two commercially available MLC models have been assessed and the results support monthly test frequency for widely accepted ±1 mm specifications. Higher QC test frequency is however required to maintain tighter specification and in-control behavior.

07 ISOTOPE AND RADIATION SOURCES↗

Static metrology of the meter-scale deformable heliostat

This paper describes a heliostat metrology system which is developed based on deflectometry, utilizing a static perforated panel instead of conventional dynamic monitor displays to provide incident rays. The developed method is named static screen deflectometry (SSD). This robust and scalable method is especially valuable for outdoor tests of large reflectors used in concentrating solar-thermal power (CSP) systems. The developed method has been successfully demonstrated on a 2.4 𝑚 × 3.3 𝑚 float glass deformable reflector bent to focus sunlight at 113 𝑚 distance throughout a day. From images obtained from a camera at 50𝑚 distance, the reflector surface was measured to an accuracy of less than 1 𝑚𝑟𝑎𝑑 rms slope error in the full test scope.

14 SOLAR ENERGY↗

Study on Static Recrystallization Behavior of Medium-Carbon Cr-Ni-Mo Alloyed Steel During Hot Deformation

A series of two-pass hot compression tests were conducted on Gleeble-1500 thermo-mechanical simulator to investigate the static recrystallization (SRX) behavior of a medium-carbon Cr-Ni-Mo alloyed steel 34CrNiMo. The compression tests were performed at a deformation temperature range of 950-1150 °C, a strain rate range of 0.1-3.5 s{sup −1}, and an interval time range of 1-100 s. The experimental flow stress curves and microstructural observation indicate that deformation temperature, pass interval time, strain rate, and pre-strain have significant influences on the recrystallization behavior of 34CrNiMo steel. It is identified that the softening fraction increases with the increasing deformation temperature, pre-strain, and interval time, while it decreases with the increasing strain rate. Based on the experimental data, the SRX kinetics equations of 34CrNiMo steel were developed. And the calculated results are in good agreement with the experimental ones, which demonstrates that the established equations can be used to describe the SRX behavior of 34CrNiMo steel at elevated temperatures.

36 MATERIALS SCIENCE↗

Automating linear accelerator quality assurance

Purpose: The purpose of this study was 2-fold. One purpose was to develop an automated, streamlined quality assurance (QA) program for use by multiple centers. The second purpose was to evaluate machine performance over time for multiple centers using linear accelerator (Linac) log files and electronic portal images. The authors sought to evaluate variations in Linac performance to establish as a reference for other centers. Methods: The authors developed analytical software tools for a QA program using both log files and electronic portal imaging device (EPID) measurements. The first tool is a general analysis tool which can read and visually represent data in the log file. This tool, which can be used to automatically analyze patient treatment or QA log files, examines the files for Linac deviations which exceed thresholds. The second set of tools consists of a test suite of QA fields, a standard phantom, and software to collect information from the log files on deviations from the expected values. The test suite was designed to focus on the mechanical tests of the Linac to include jaw, MLC, and collimator positions during static, IMRT, and volumetric modulated arc therapy delivery. A consortium of eight institutions delivered the test suite at monthly or weekly intervals on each Linac using a standard phantom. The behavior of various components was analyzed for eight TrueBeam Linacs. Results: For the EPID and trajectory log file analysis, all observed deviations which exceeded established thresholds for Linac behavior resulted in a beam hold off. In the absence of an interlock-triggering event, the maximum observed log file deviations between the expected and actual component positions (such as MLC leaves) varied from less than 1% to 26% of published tolerance thresholds. The maximum and standard deviations of the variations due to gantry sag, collimator angle, jaw position, and MLC positions are presented. Gantry sag among Linacs was 0.336 ± 0.072 mm. The standard deviation in MLC position, as determined by EPID measurements, across the consortium was 0.33 mm for IMRT fields. With respect to the log files, the deviations between expected and actual positions for parameters were small (<0.12 mm) for all Linacs. Considering both log files and EPID measurements, all parameters were well within published tolerance values. Variations in collimator angle, MLC position, and gantry sag were also evaluated for all Linacs. Conclusions: The performance of the TrueBeam Linac model was shown to be consistent based on automated analysis of trajectory log files and EPID images acquired during delivery of a standardized test suite. The results can be compared directly to tolerance thresholds. In addition, sharing of results from standard tests across institutions can facilitate the identification of QA process and Linac changes. These reference values are presented along with the standard deviation for common tests so that the test suite can be used by other centers to evaluate their Linac performance against those in this consortium.

60 APPLIED LIFE SCIENCES↗

House Advantage or House of Cards? Stacking the Deck for Data Videos Leads to Null Results: Preprint

Videos are becoming a ubiquitous means of sharing information on social media platforms. In response, data videos - short clips combining visualization with dynamic storytelling, audio descriptions, and spatial referencing - have gained popularity for communicating data. These affordances suggest that data videos might communicate data patterns, trends, and concepts more effectively than static visualizations, enhancing comprehension. However, existing research has not systematically tested this claim. To address this gap, we conducted three controlled studies to measure comprehension differences between data videos and static visualizations. Despite leveraging visual cues and audio explanations, no data video led to significantly better comprehension than an analogous static visualization. Our results suggest data videos are not categorically better and that future research should examine the tradeoffs between their engagement benefits and costs.

97 MATHEMATICS AND COMPUTING↗

MBM fuel feeding system design and evaluation for FBG pilot plant

Highlights: Black-Right-Pointing-Pointer A 1-5 g/s fuel feeding system for pilot scale FBG was designed, built and tested. Black-Right-Pointing-Pointer Multiple conveying stages improve pressure balancing, flow control and stability. Black-Right-Pointing-Pointer Secondary conveyor stage reduced output irregularity from 47% to 15%. Black-Right-Pointing-Pointer Pneumatic air sparging effective in dealing with poor flow ability of MBM powder. Black-Right-Pointing-Pointer Pneumatic injection port plugs with char at gasification temperature of 850 Degree-Sign C. - Abstract: A biomass fuel feeding system has been designed, constructed and evaluated for a fluidized bed gasifier (FBG) pilot plant at the University of Saskatchewan (Saskatoon, SK, Canada). The system was designed for meat and bone meal (MBM) to be injected into the gasifier at a mass flow-rate range of 1-5 g/s. The designed system consists of two stages of screw conveyors, including a metering stage which controlled the flow-rate of fuel, a rotary airlock and an injection conveyor stage, which delivered that fuel at a consistent rate to the FBG. The rotary airlock which was placed between these conveyors, proved unable to maintain a pressure seal, thus the entire conveying system was sealed and pressurized. A pneumatic injection nozzle was also fabricated, tested and fitted to the end of the injection conveyor for direct injection and dispersal into the fluidized bed. The 150 mm metering screw conveyor was shown to effectively control the mass output rate of the system, across a fuel output range of 1-25 g/s, while the addition of the 50 mm injection screw conveyor reduced the irregularity (error) of the system output rate from 47% to 15%. Although material plugging was found to be an issue in the inlet hopper to the injection conveyor, the addition of air sparging ports and a system to pulse air into those ports was found to successfully eliminate this issue. The addition of the pneumatic injection nozzle reduced the output irregularity further to 13%, with an air supply of 50 slpm as the minimum air supply to drive this injector. After commissioning of this final system to the FBG reactor, the injection nozzle was found to plug with char however, and was subsequently removed from the system. Final operation of the reactor continues satisfactorily with the two screw conveyors operating at matching pressure with the fluidized bed, with the output rate of the system estimated based on system characteristic equations, and confirmed by static weight measurements made before and after testing. The error rate by this method is reported to be approximately 10%, which is slightly better than the estimated error rate of 15% for the conveyor system. The reliability of this measurement prediction method relies upon the relative consistency of the physical properties of MBM with respect to its bulk density and feeding characteristics.

09 BIOMASS FUELS↗

Extending evolutionary forecasts across bacterial species

Improving evolutionary forecasting requires progressing from studying repeated evolution of a single genotype under identical conditions to formulating broad principles. These principles should enable predictions of how similar species will adapt to similar selective pressures. Evolve-and-resequence experiments with multiple species allow testing forecasts on different biological levels and elucidating the causes for failed predictions. Here, we show that forecasts for adaptation to static culture conditions can be extended to multiple species by testing previous predictions for Pseudomonas syringae and Pseudomonas savastanoi. In addition to sequence divergence, these species differ in their repertoire of biofilm regulatory genes and structural components. Consistent with predictions, both species repeatedly produced biofilm mutants with a wrinkly spreader phenotype. Predominantly, mutations occurred in the wsp operon, with less frequent promoter mutations near uncharacterized diguanylate cyclases. However, mutational patterns differed on the gene level, which was explained by a lack of conservation in relative fitness of mutants between more divergent species. The same mutation was the most frequent for both species suggesting that conserved mutation hotspots can increase parallel evolution. This study shows that evolutionary forecasts can be extended across species, but that differences in the genotype–phenotype–fitness map and mutational biases limit predictability on a detailed molecular level.

59 BASIC BIOLOGICAL SCIENCES↗

Duct Leakage Modeling in EnergyPlus and Analysis of Energy Savings from Implementing SAV with InCITeTM

This project addressed two significant deficiencies in air-handling systems for large commercial building: duct leakage and duct static pressure reset. Both constitute significant energy reduction opportunities for these buildings. The overall project goal is to bridge the gaps in current duct performance modeling capabilities, and to expand our understanding of air-handling system performance in California large commercial buildings. The purpose of this project is to provide technical support for the implementation of a duct leakage modeling capability in EnergyPlus, to demonstrate the capabilities of the new model, and to carry out analyses of field measurements intended to demonstrate the energy saving potential of the SAV with InCITeTM duct static pressure reset (SPR) technology. A new duct leakage model has been successfully implemented in EnergyPlus, which will enable simulation users to assess the impacts of leakage on whole-building energy use and operation in a coupled manner. This feature also provides a foundation to support code change proposals and compliance analyses related to Title 24 where duct leakage is an issue. Our example simulations continue to show that leaky ducts substantially increase fan power: 10percent upstream and 10percent downstream leakage increases supply fan power 30percent on average compared to a tight duct system (2.5percent upstream and 2.5percent downstream leakage). Much of this increase is related to the upstream leakage rather than to the downstream leakage. This does not mean, however, that downstream leakage is unimportant. Our simulations also demonstrate that ceiling heat transfer is a significant effect that needs to be included when assessing the impacts of duct leakage in large commercial buildings. This is not particularly surprising, given that ?ceiling regain? issues have already been included in residential analyses as long as a decade ago (e.g., ASHRAE Standard 152); mainstream simulation programs that are used for large commercial building energy analyses have not had this capability until now. Our analyses of data that we collected during our 2005 tests of the SAV with InCITeTM duct static pressure reset technology show that this technology can substantially reduce fan power (in this case, by about 25 to 30percent). Tempering this assessment, however, is that cooling and heating coil loads were observed to increase or decrease significantly depending on the time window used. Their impact on cooling and heating plant power needs to be addressed in future studies; without translating the coil loads to plant equipment energy use, it is not possible to judge the net impact of this SPR technology on whole-building energy use. If all of the loads had decreased, such a step would not be as necessary.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic Matrix Completion Based State Estimation in Distribution Grids

The power distribution network is undergoing tremendous transformation due to an increase in the penetration of renewable energy resources and electric vehicles. These changes have resulted in greater uncertainty and dynamics in the distribution grid states. Therefore, the ability to track and monitor system states has become a critical need for accurate and timely control actions. In this paper, we propose two dynamic sparsity-based state estimation approaches for distribution systems: (1) locally weighted matrix completion (LW-MC) and (2) Bayesian matrix completion with Kalman filter prediction (BMC-KF). The performance of the proposed dynamic state estimation strategies is compared with the classic/static matrix completion (static-MC) approach using the IEEE 37 and IEEE 123 bus test systems. Finally, results indicate that BMC-KF approach outperforms both LW-MC as well as static-MC even when 30% of the measurement data is available. Computational complexity associated with both approaches is quantified.

42 ENGINEERING↗

Corrosion resistance of alumina forming alloys against molten chlorides for energy production. II: Electrochemical impedance spectroscopy under thermal cycling conditions

Next-generation power systems require higher temperatures to increase the efficiency of electricity production in the power block. Concentrating solar power (CSP) technology is looking for high temperature thermal fluids able to work in the range of 550–750 °C. Molten chlorides containing NaCl, KCl, MgCl 2 , and/or ZnCl 2 are being considered for solar receivers and/or sensible- or latent- thermal energy storage systems. Vapor pressures of chlorides are high enough that in combination with oxygen gaseous compounds will produce a harsh atmosphere that is generally very aggressive to common chromia forming alloys. Corrosion mitigations must consider a solution in which both zones (immersed in fluid and exposed to vapor phase) will be protected. This could easily be obtained using alloy surface modification approaches. Surface passivation, produced after pre-oxidation treatments, of alumina forming alloys (Inconel 702, Haynes 224 and Kanthal APMT) was evaluated in molten 35.59 wt% MgCl2 – 64.41 wt% KCl thermally cycled from 550 °C to 700 °C in flowing Ar and static zero air (ZA) atmospheres. Electrochemical impedance spectroscopy tests and metallographic characterization showed that the best performing alloy was pre-oxidized In702 in ZA at 1050 °C for 4 h due to the formation of protective, dense and continuous alumina layers. The alumina layers were unstable when flowing Ar was used as the inert atmosphere during corrosion evaluations. Corrosion results in static ZA are promising for next-generation CSP applications using molten chlorides because alumina scales were stable after 185 h of immersion in the oxygen-containing atmosphere. Alumina layers in pre-oxidized Al-FA In702 grew from 5 µm (before immersion) to 13 µm (after 185 h of immersion). As a result, the use of these alloys could be commercial feasibility and cost-effective because of the possibility of using oxygen-containing atmospheres instead of keeping enclosed systems with inert atmospheres to protect alloys from corrosion in molten chlorides.

14 SOLAR ENERGY↗

A scalable compressible volume of fluid solver using a stratified flow model

Here, in this paper, a Volume of Fluid method which uses a Stratified Flow model for flux calculation is proposed to solve a compressible multiphase flow in a way that has high parallel efficiency. The solver is part of an open-source computing tool to study fuel entrainment and combustion in the application of paraffin-based hybrid rocket motors. This paper focuses on the compressible Volume of Fluid solver for the liquid and gaseous phases in this environment. This solver uses perfect gas and stiffened gas models for equation of state, with the ability to easily add other models as desired. Additionally a comparison of a Riemann solver versus an AUSM+up scheme is conducted, showing improvement with the later in the solution of multiphase flows. This solver successfully reproduces shock tube cases with the expected accuracy, as well as simulating two-dimensional shear and gravity-driven flows. Results also show that the code is able to utilize a Stratified Flow model to evaluate shear flow without the need for interface reconstruction or gradient calculations. Finally, it is shown that the solver has near-ideal scaling under strong scaling tests as well as good performance in static scaling, giving improved performance over current options and implying future advancement of high-performance computing efficiency for multiphase flow solvers.

97 MATHEMATICS AND COMPUTING↗

Detection and characterization of uranium-humic complexes during 1D transport studies

The speciation and transport of uranium (VI) through porous media is highly dependent on solution conditions, the presence of complexing ligands, and the nature of the porous media. The dependency on many variables makes prediction of U transport in bench-scale experiments and in the field difficult. In particular, the identification of colloidal U phases poses a technical challenge. Transport of U in the presence and absence of natural organic matter (Suwannee River humic acid, SRHA) through silica sand and hematite coated silica sand was tested at pH 4 and 5 using static columns, where flow is controlled by gravity and residence time between advective pore volume exchanges can be strictly controlled. The column effluents were characterized by traditional techniques including ICPMS quantification of total [U] and [Fe], TOC analysis of [DOC], and pH analysis, and also by non-traditional techniques: flow field flow fractionation with online ICPMS detection (FlFFF-ICPMS) and specific UV absorbance (SUVA) characterization of effluent fractions. Key results include that the transport of U through the columns was enhanced by pre-equilibration with SRHA, and previously deposited U was remobilized by the addition of SRHA. The advanced techniques yielded important insights on the mechanisms of transport: FlFFF-ICPMS identified a U-SRHA complex as the mobile U species and directly quantified relative amounts of the complex, while specific UV absorbance (SUVA) measurements indicated a composition-based fractionation onto the porous media.

54 ENVIRONMENTAL SCIENCES↗

Tracking Accuracy of a Real-Time Fiducial Tracking System for Patient Positioning and Monitoring in Radiation Therapy

Purpose: In radiation therapy there is a need to accurately know the location of the target in real time. A novel radioactive tracking technology has been developed to answer this need. The technology consists of a radioactive implanted fiducial marker designed to minimize migration and a linac mounted tracking device. This study measured the static and dynamic accuracy of the new tracking technology in a clinical radiation therapy environment. Methods and Materials: The tracking device was installed on the linac gantry. The radioactive marker was located in a tissue equivalent phantom. Marker location was measured simultaneously by the radioactive tracking system and by a Microscribe G2 coordinate measuring machine (certified spatial accuracy of 0.38 mm). Localization consistency throughout a volume and absolute accuracy in the Fixed coordinate system were measured at multiple gantry angles over volumes of at least 10 cm in diameter centered at isocenter. Dynamic accuracy was measured with the marker located inside a breathing phantom. Results: The mean consistency for the static source was 0.58 mm throughout the tested region at all measured gantry angles. The mean absolute position error in the Fixed coordinate system for all gantry angles was 0.97 mm. The mean real-time tracking error for the dynamic source within the breathing phantom was less than 1 mm. Conclusions: This novel radioactive tracking technology has the potential to be useful in accurate target localization and real-time monitoring for radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microstructure and mechanical behavior of direct metal laser sintered Inconel alloy 718

In this paper, we investigate microstructure and quasi-static mechanical behavior of the direct metal laser sintered Inconel 718 superalloy as a function of build direction (BD). The printed material was further processed by annealing and double-aging, hot isostatic pressing (HIP), and machining. We characterize porosity fraction and distribution using micro X-ray computed tomography (μXCT), grain structure and crystallographic texture using electron backscattered diffraction (EBSD), and mechanical response in quasi-static tension and compression using standard mechanical testing at room temperature. Analysis of the μXCT imaging shows that majority of porosity develops in the outer layer of the printed material. However, porosity inside the material is also present. The EBSD measurements reveal formation of columnar grains, which favor < 001 > fiber texture components along the BD. These measurements also show evidence of coarse-grained microstructure present in the samples treated by HIP. Finally, analysis of grain boundaries reveal that HIP results in a large number of annealing twins compared to that in samples that underwent annealing and double-aging. The yield strength varies with the testing direction by approximately 7%, which is governed by a combination of grain morphology and crystallographic texture. In particular, we determine tension–compression asymmetry in the yield stress as well as anisotropy of the material flow during compression. We find that HIP lowers yield stress but improves ductility relative to the annealed and aged material. These results are discussed and critically compared with the data reported for wrought material in the same condition. - Highlights: • Microstructure and mechanical properties of DMLS Inconel 718 are studied in function of build direction. • Inhomogeneity of microstructure in the material in several conditions is quantified by μXCT and EBSD. • Anisotropy and asymmetry in the mechanical response are determined by tension and compression testing.

36 MATERIALS SCIENCE↗

High frequency content in nonlinear soil response: A numerical artifact or a reality?

This article probes the reasons for the presence of high frequency components, which are not a part of the input, in the output of nonlinear site response analysis. The nonlinear site response analysis of a single soil element, under a single frequency sinusoidal displacement, is conducted to demonstrate the presence of frequencies higher than the input frequency in the soil element's shear stress and the free surface acceleration. The parameters of this one element problem are chosen carefully to minimize numerical errors. The shape of the stress-strain hysteresis loop is found to be the main cause for the presence of these higher frequencies. A quasi-static problem similar to the direct shear test is then considered to analyze the effect of different hysteresis shapes. Through this analysis, it is numerically and analytically shown that any deviation of the stress-strain hysteresis shape from a perfect ellipse results in output frequencies higher than the input frequency and the number of higher frequencies produced depends on whether the hysteresis shape is smooth or pointed.

42 ENGINEERING↗

Imaginary time correlations and the phaseless auxiliary field quantum Monte Carlo

The phaseless Auxiliary Field Quantum Monte Carlo (AFQMC) method provides a well established approximation scheme for accurate calculations of ground state energies of many-fermions systems. Here we address the possibility of calculating imaginary time correlation functions with the phaseless AFQMC. We give a detailed description of the technique and test the quality of the results for static properties and imaginary time correlation functions against exact values for small systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A superradiance-based biological switch

Using the concept of Superradiance Transition, we formulate the operational principles of a quantum device which can be used as a witness of wave-like behavior in molecular chains. We also test its reliability under the action of static diagonal noise, dephasing and phonon thermal bath at room temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗