Search NASA⌕ Search

SEARCH · Search NASA

Results for “structure imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Temperature-driven growth of antiferromagnetic domains in thin-film FeRh

The evolution of the antiferromagnetic phase across the temperature-driven ferromagnetic (FM) to antiferromagnetic (AF) phase transition in epitaxial FeRh thin films was studied by x-ray magnetic linear and circular dichroism (XMLD and XMCD) and photoemission electron microscopy. By comparing XMLD and XMCD images recorded at the same temperature, the AF phase was identified, its structure directly imaged, and its evolution studied across the transition. A quantitative analysis of the correlation length of the images shows differences between the characteristic length scale of the two phases with the AF phase having a finer feature size. The asymmetry of the transition from FM to AF upon cooling and AF-FM upon heating is evidenced: upon cooling the formation of AF phase is dominated by nucleation at defects, with little subsequent growth, resulting in a small and non-random final AF domain structure, while upon heating, heterogeneous nucleation at different sites followed by significant domain size growth of the FM phase is observed, resulting in a non-reproducible final FM large domain structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In Operando XANES Imaging of High Capacity Intermetallic Anodes for Lithium Ion Batteries

In operando 2D X-ray absorption near edge structure (XANES) imaging was performed near the Cu K-edge during cycling of Cu 6 Sn 5 composite anodes for lithium ion batteries. Galvanostatic lithiation and delithiation with intermittent constant voltage holds near reaction plateaus show evolution of absorption spectra for active material particles. XANES spectra obtained from images taken during cycling were compared to standard spectra for Cu, Cu 6 Sn 5 , and Li 2 CuSn. Chemical composition was assessed for Cu-containing phases. Distinct Cu, Cu 6 Sn 5 , and Li 2 CuSn regions were identified for each voltage plateau. Mechanical degradation, electrode particle fracture and expansion were observed during delithiation. Furthermore, movement of particles during cycling suggests that expansion also impacts the supporting secondary phases and the transport networks therein. These results demonstrate that spectroscopic X-ray imaging methods can clearly distinguish chemically distinct phases in alloy electrodes and have the versatility to observe the evolution of these phases during lithiation and delithiation.

25 ENERGY STORAGE↗

Towards automating structural discovery in scanning transmission electron microscopy *

Abstract Scanning transmission electron microscopy is now the primary tool for exploring functional materials on the atomic level. Often, features of interest are highly localized in specific regions in the material, such as ferroelectric domain walls, extended defects, or second phase inclusions. Selecting regions to image for structural and chemical discovery via atomically resolved imaging has traditionally proceeded via human operators making semi-informed judgements on sampling locations and parameters. Recent efforts at automation for structural and physical discovery have pointed towards the use of ‘active learning’ methods that utilize Bayesian optimization with surrogate models to quickly find relevant regions of interest. Yet despite the potential importance of this direction, there is a general lack of certainty in selecting relevant control algorithms and how to balance a priori knowledge of the material system with knowledge derived during experimentation. Here we address this gap by developing the automated experiment workflows with several combinations to both illustrate the effects of these choices and demonstrate the tradeoffs associated with each in terms of accuracy, robustness, and susceptibility to hyperparameters for structural discovery. We discuss possible methods to build descriptors using the raw image data and deep learning based semantic segmentation, as well as the implementation of variational autoencoder based representation. Furthermore, each workflow is applied to a range of feature sizes including NiO pillars within a La:SrMnO 3 matrix, ferroelectric domains in BiFeO 3 , and topological defects in graphene. The code developed in this manuscript is open sourced and will be released at github.com/nccreang/AE_Workflows .

47 OTHER INSTRUMENTATION↗

Actinic imaging and evaluation of phase structures on EUV lithography masks

The authors describe the implementation of a phase-retrieval algorithm to reconstruct phase and complex amplitude of structures on EUV lithography masks. Many native defects commonly found on EUV reticles are difficult to detect and review accurately because they have a strong phase component. Understanding the complex amplitude of mask features is essential for predictive modeling of defect printability and defect repair. Besides printing in a stepper, the most accurate way to characterize such defects is with actinic inspection, performed at the design, EUV wavelength. Phase defect and phase structures show a distinct through-focus behavior that enables qualitative evaluation of the object phase from two or more high-resolution intensity measurements. For the first time, phase of structures and defects on EUV masks were quantitatively reconstructed based on aerial image measurements, using a modified version of a phase-retrieval algorithm developed to test optical phase shifting reticles.

36 MATERIALS SCIENCE↗

Multislice forward modeling of coherent surface scattering imaging on surface and interfacial structures

To study nanostructures on substrates, surface-sensitive reflection-geometry scattering techniques such as grazing incident small angle X-ray scattering are commonly used to yield an averaged statistical structural information of the surface sample. Grazing incidence geometry can probe the absolute three-dimensional structural morphology of the sample if a highly coherent beam is used. Coherent surface scattering imaging (CSSI) is a powerful yet non-invasive technique similar to coherent X-ray diffractive imaging (CDI) but performed at small angles and grazing-incidence reflection geometry. A challenge with CSSI is that conventional CDI reconstruction techniques cannot be directly applied to CSSI because the Fourier-transform-based forward models cannot reproduce the dynamical scattering phenomenon near the critical angle of total external reflection of the substrate-supported samples. To overcome this challenge, we have developed a multislice forward model which can successfully simulate the dynamical or multi-beam scattering generated from surface structures and the underlying substrate. The forward model is also demonstrated to be able to reconstruct an elongated 3D pattern from a single shot scattering image in the CSSI geometry through fast-performing CUDA-assisted PyTorch optimization with automatic differentiation.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Manifold projection image segmentation for nano-XANES imaging

As spectral imaging techniques are becoming more prominent in science, advanced image segmentation algorithms are required to identify appropriate domains in these images. We present a version of image segmentation called manifold projection image segmentation (MPIS) that is generally applicable to a broad range of systems without the need for training because MPIS uses unsupervised machine learning with a few physically motivated hyperparameters. We apply MPIS to nanoscale x-ray absorption near edge structure (XANES) imaging, where XANES spectra are collected with nanometer spatial resolution. We show the superiority of manifold projection over linear transformations, such as the commonly used principal component analysis (PCA). Moreover, MPIS maintains accuracy while reducing computation time and sensitivity to noise compared to the standard nano-XANES imaging analysis procedure. Finally, we demonstrate how multimodal information, such as x-ray fluorescence data and spatial location of pixels, can be incorporated into the MPIS framework. We propose that MPIS is adaptable for any spectral imaging technique, including scanning transmission x-ray microscopy, where the length scale of domains is larger than the resolution of the experiment.

36 MATERIALS SCIENCE↗

TPSAS-NF1676L-32540-DND

The supersonic/hypersonic ground testing serves a multitude of purposes and objectives. From structural and material integrity, to force and moment models; from pressure mapping, thermal imaging, shock structure to scramjet/ramjet engine operability and ignition studies. Hypersonics has become more of a high profile area of late. Compared to flight testing, ground testing typically it is less expensive and usually is not a one single-test test program. It is more forgiving in the fact that a test program can utilize a single test article and get data from a number of tests. Ground test data is the input to the formation of research databases, as well as, validation of CFD models/tools. To understand the output, one must first understand the inputs. To achieve supersonic/hypersonic speeds the use of compressors or compressed air storage along with converging-diverging nozzles are needed. Flight temperatures also need to be achieved for the ground test to truly simulate flight conditions. At NASA Langley's 8' High Temperature Tunnel (HTT), compressed natural gas (methane) is burned to heat the air. To validate that the desired test condition is met, test instrumentation is used and data is collected from the combustor all the way through the nozzle exit plane. In this talk, NASA Langley's 8' HTT will be the basis for what kind of test capabilities hypersonic ground testing offers. It certainly does not offer every capability within ground testing, nor will the discussion cover all types. Specific test techniques used and data collection methods will be discussed and how these confirm certain flight conditions have been achieved. There will be subsequent thoughts on experimental methods that aid test articles such as thrust stands, model actuation, etc.

Aaron W Fuchs↗

Super-resolution reconstruction in frequency, image, and wavelet domains to reduce through-plane partial voluming in MRI

Purpose: To compare and evaluate the use of super-resolution reconstruction (SRR), in frequency, image, and wavelet domains, to reduce through-plane partial voluming effects in magnetic resonance imaging. Methods: The reconstruction of an isotropic high-resolution image from multiple thick-slice scans has been investigated through techniques in frequency, image, and wavelet domains. Experiments were carried out with thick-slice T2-weighted fast spin echo sequence on the Academic College of Radiology MRI phantom, where the reconstructed images were compared to a reference high-resolution scan using peak signal-to-noise ratio (PSNR), structural similarity image metric (SSIM), mutual information (MI), and the mean absolute error (MAE) of image intensity profiles. The application of super-resolution reconstruction was then examined in retrospective processing of clinical neuroimages of ten pediatric patients with tuberous sclerosis complex (TSC) to reduce through-plane partial voluming for improved 3D delineation and visualization of thin radial bands of white matter abnormalities. Results: Quantitative evaluation results show improvements in all evaluation metrics through super-resolution reconstruction in the frequency, image, and wavelet domains, with the highest values obtained from SRR in the image domain. The metric values for image-domain SRR versus the original axial, coronal, and sagittal images were PSNR = 32.26 vs 32.22, 32.16, 30.65; SSIM = 0.931 vs 0.922, 0.924, 0.918; MI = 0.871 vs 0.842, 0.844, 0.831; and MAE = 5.38 vs 7.34, 7.06, 6.19. All similarity metrics showed high correlations with expert ranking of image resolution with MI showing the highest correlation at 0.943. Qualitative assessment of the neuroimages of ten TSC patients through in-plane and out-of-plane visualization of structures showed the extent of partial voluming effect in a real clinical scenario and its reduction using SRR. Blinded expert evaluation of image resolution in resampled out-of-plane views consistently showed the superiority of SRR compared to original axial and coronal image acquisitions. Conclusions: Thick-slice 2D T2-weighted MRI scans are part of many routine clinical protocols due to their high signal-to-noise ratio, but are often severely affected by through-plane partial voluming effects. This study shows that while radiologic assessment is performed in 2D on thick-slice scans, super-resolution MRI reconstruction techniques can be used to fuse those scans to generate a high-resolution image with reduced partial voluming for improved postacquisition processing. Qualitative and quantitative evaluation showed the efficacy of all SRR techniques with the best results obtained from SRR in the image domain. The limitations of SRR techniques are uncertainties in modeling the slice profile, density compensation, quantization in resampling, and uncompensated motion between scans.

60 APPLIED LIFE SCIENCES↗

Updimensioning strategy derived from synthetic equiaxed grain structures for approximating 3D grain size distributions from 2D visualizations with 1D parameters

We generated synthetic equiaxed grain structures using computer graphics software to explore the relationship between various grain size determination methods and true three-dimensional (3D) grain diameters. Mirroring grain measurement techniques, the synthetic 3D grain structures are imaged as 2D micrographs which are measured to yield 1D grain size parameters. Synthetic grain structures provide data at a mass scale and permit exploration of both polished and fractured surface micrographs, revealing one-to-one correspondence between exposed 2D grain cross-sections and individual 3D grains. Analysis of this correspondence yielded a procedure to approximate 3D equiaxed grain size and volume distributions based on the mode of the 2D fractograph grain size distribution. The 3D approximation procedure is shown to be less susceptible to different imaging conditions that affect small, undiscernible grains compared to the standard planimetric and linear intercept methods, which by design also tend to underestimate the 3D grain diameter. The procedure requires larger sample sizes to lower variance and a deeper analysis which could become more practical with machine learning (ML) models for grain boundary segmentation, which synthetic grain structures can help train. This work lays the foundation for analyzing other grain distributions such as columnar and composite grains in similar depth.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multitemporal diurnal AVIRIS images of a forested ecosystem

Both physiological and ecosystem structural information may be derived from diurnal images. Structural information may be inferred from changes in canopy shadows between images and from changes in spectral composition due to changes in proportions of subpixel mixing resulting from the differences in sun/view angles. Physiological processes having diurnal scales also may be measurable if a stable basis for spectral comparison can be established. Six diurnal images of an area east of Mt. Shasta, CA were acquired on 22 Sep. 1989. This unique diurnal data set provided an opportunity to test the consistency of endmember fractions and residuals. It was expected that shade endmember abundances would show the greatest change as lighting geometry changed and less change in the normalized fractional proportion of other endmembers. Diurnal changes in spectral features related to physiological characteristics may be identifiable as changes in wavelength specific residuals.

Ustin, Susan L.↗

Mitigating Worst-Case Exozodiacal Dust Structure in High-Contrast Images of Earth-Like Exoplanets

Detecting Earth-like exoplanets in direct images of nearby Sun-like systems brings a unique set of challenges that must be addressed in the early phases of designing a space-based direct imaging mission. In particular, these systems may contain exozodiacal dust, which is expected to be the dominant source of astrophysical noise. Previous work has shown that it may be feasible to subtract smooth, symmetric dust from observations; however, we do not expect exozodiacal dust to be perfectly smooth. Exozodiacal dust can be trapped into mean-motion resonances with planetary bodies, producing large-scale structures that orbit in lock with the planet. This dust can obscure the planet, complicate noise estimation, or be mistaken for a planetary body. Our ability to subtract these structures from high-contrast images of Earth-like exoplanets is not well understood. In this work, we investigate exozodi mitigation for Earth–Sun-like systems with significant mean-motion resonant disk structures. We find that applying a simple high-pass filter allows us to remove structured exozodi to the Poisson noise limit for systems with inclinations <60° and up to 100 zodis. However, subtracting exozodiacal disk structures from edge-on systems may be challenging, except for cases with densities <5 zodis. For systems with three times the dust of the solar system, which is the median of the best fit to survey data in the habitable zones of nearby Sun-like stars, this method shows promising results for mitigating exozodiacal dust in future Habitable Worlds Observatory observations, even if the dust exhibits significant mean-motion resonance structure.

Miles H. Currie↗

Polarization and phase pulse shaping applied to structural contrast in nonlinear microscopy imaging

The spectral polarization shaping of ultrashort pulses is shown to allow retrieval of two-dimensional individual tensorial components of the second-harmonic-generation response of molecular samples in nonlinear microscopy imaging. This configuration, which cannot be performed by traditional polarization-controlled excitation, provides a structural contrast that can be directly related to information on the local symmetry and order of the sample, with submicrometric spatial resolution. Phase shaping, in addition to polarization spectral manipulation, is proposed as a possible scheme for imaging individual tensorial components without the need for a spectral information extraction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Active Learning Surrogates for Integrating Electron Microscopy and Computational Insights from Simulations in Autonomous Experiments

Artificial Intelligence (AI) combined with simulations and experiments has great potential to accelerate scientific discovery across technology and pharmaceuticals. However, the gap between simulations and experiments is challenging due to disparities in time and scale, making it difficult to estimate properties like energy and electronic states from experiments, and to provide feedback based on theoretical insights.Our research addresses the challenge by developing unique deep kernel based surrogate models that learns from microscopic images, mapping structural features to energy differences from defect formation. We start with full-training using simulated images to determine optimal settings, establishing a baseline for active learning. Using these settings from the baseline, active learning is trained, and predicts structures along simulation trajectories based on uncertainty and energetic stability, thus reducing data requirements, simulation time and computational costs. The results demonstrate that the model achieves a low average error margin of approximately 0.03 meV, indicating good performance. To enhance feature extraction and reconstruction capabilities, we developed an autoencoder-decoder as additional surrogate to create latent space to capture essential features, enabling precise comparisons between simulations and experiments. The results from this model achieved a reconstruction loss of around 0.2 and accurately reconstructed molecular structures.Overall, this work advances the steering of experiments through computational simulations by employing a surrogate models that actively predicts the trajectories of structural evolution, achieving time-to-solution comparable to experimental measurements.

Saranathan, Gayathri [Hewlett-Packard]↗

Method and system for the diagnosis of disease using retinal image content and an archive of diagnosed human patient data

A method for diagnosing diseases having retinal manifestations including retinal pathologies includes the steps of providing a CBIR system including an archive of stored digital retinal photography images and diagnosed patient data corresponding to the retinal photography images, the stored images each indexed in a CBIR database using a plurality of feature vectors, the feature vectors corresponding to distinct descriptive characteristics of the stored images. A query image of the retina of a patient is obtained. Using image processing, regions or structures in the query image are identified. The regions or structures are then described using the plurality of feature vectors. At least one relevant stored image from the archive based on similarity to the regions or structures is retrieved, and an eye disease or a disease having retinal manifestations in the patient is diagnosed based on the diagnosed patient data associated with the relevant stored image(s).

Tobin, Jr., Kenneth William↗

Method and system for the diagnosis of disease using retinal image content and an archive of diagnosed human patient data

A method for diagnosing diseases having retinal manifestations including retinal pathologies includes the steps of providing a CBIR system including an archive of stored digital retinal photography images and diagnosed patient data corresponding to the retinal photography images, the stored images each indexed in a CBIR database using a plurality of feature vectors, the feature vectors corresponding to distinct descriptive characteristics of the stored images. A query image of the retina of a patient is obtained. Using image processing, regions or structures in the query image are identified. The regions or structures are then described using the plurality of feature vectors. At least one relevant stored image from the archive based on similarity to the regions or structures is retrieved, and an eye disease or a disease having retinal manifestations in the patient is diagnosed based on the diagnosed patient data associated with the relevant stored image(s).

59 BASIC BIOLOGICAL SCIENCES↗

Wavelet-based algorithm for correction of beam-steering artefacts in turbulent flow imaging at elevated pressures

Beam steering by index-of-refraction gradients poses a significant challenge for laser-based imaging measurements in turbulent reacting and non-reacting flows, particularly at elevated pressures. High fidelity imaging and quantitative data interpretation in turbulent flows can be considerably impeded by artefacts generated from beam steering. A wavelet-based filtering scheme has been developed to recover the underlying turbulent flow structures from imaging measurements containing severe beam-steering artefacts. This analysis technique is equally applicable to imaging measurements in reacting and non-reacting flows. It is demonstrated using mixture fraction measurements in a transient turbulent jet flow at 8 bar using Rayleigh scattering imaging at a repetition rate of 100 kHz. In this paper, the corrected images reveal the temporal evolution of flow structures with negligible residual beam-steering artefacts. Tests of the sensitivity of the wavelet-based filtering scheme to noise and spatial resolution indicate that it is a robust analytic tool for correcting severe beam-steering artefacts commonly encountered in laser-based imaging measurements at elevated pressures.

47 OTHER INSTRUMENTATION↗

Ultrasparse View X-ray Computed Tomography for 4D Imaging

X-ray computed tomography (CT) is a noninvasive, nondestructive approach to imaging materials, material systems, and engineered components in two and three dimensions. Acquisition of three-dimensional (3D) images requires the collection of hundreds or thousands of through-thickness X-ray radiographic images from different angles. Such 3D data acquisition strategies commonly involve suboptimal temporal sampling for in situ and operando studies (4D imaging). Herein, we introduce a sparse-view imaging approach, Tomo-NeRF, which is capable of reconstructing high-fidelity 3D images from <10 twodimensional radiographic images. Experimental 2D and 3D X-ray images were used to test the reconstruction capability in two-view, four-view, and six-view scenarios. Tomo-NeRF is capable of reconstructing 3D images with a structural similarity of 0.9971–0.9975 and a voxel-wise accuracy of 81.83–89.59% from 2D experimentally obtained images. Furthermore, the reconstruction accuracy for the experimentally obtained images is less than the synthetic structures. Experimentally obtained images demonstrate a similarity of 0.9973–0.9984 and a voxelwise accuracy of 84.31–95.77%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗