Search NASA⌕ Search

SEARCH · Search NASA

Results for “study protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Understanding Sulfur Poisoning and Regeneration of Nickel Biomass Conditioning Catalysts using X-Ray Absorption Spectroscopy

The production of biofuels can proceed via a biomass gasification to produce syngas, which can then undergo catalytic conditioning and reforming reactions prior to being sent to a fuel synthesis reactor. Catalysts used for biomass conditioning are plagued by short lifetimes which are a result of, among other things, poisoning. Syngas produced from biomass gasification may contain between 30-300 ppm H2S, depending on the feedstock and gasification conditions, and H2S is a key catalyst poison. In order to overcome catalyst poisoning, either an H2S-tolerant catalyst or an efficient regeneration protocol should be employed. In this study, sulfur K-edge X-ray absorption near edge spectroscopy (XANES) was used to monitor sulfur species on spent catalyst samples and the transformation of these species from sulfides to sulfates during steam and air regeneration on a Ni/Mg/K/Al2O3 catalyst used to condition biomass-derived syngas. Additionally, nickel K-edge EXAFS and XANES are used to examine the state of nickel species on the catalysts. Post-reaction samples showed the presence of sulfides on the H2S-poisoned nickel catalyst and although some gaseous sulfur species were observed to leave the catalyst bed during regeneration, sulfur remained on the catalyst and a transformation from sulfides to sulfates was observed. The subsequent H2 reduction led to a partial reduction of sulfates back to sulfides. A proposed reaction sequence is presented and recommended regeneration strategies are discussed.

09 BIOMASS FUELS↗

Automatic Determination of the Need for Intravenous Contrast in Musculoskeletal MRI Examinations Using IBM Watson’s Natural Language Processing Algorithm

Magnetic resonance imaging (MRI) protocoling can be time- and resource-intensive, and protocols can often be suboptimal dependent upon the expertise or preferences of the protocoling radiologist. Providing a best-practice recommendation for an MRI protocol has the potential to improve efficiency and decrease the likelihood of a suboptimal or erroneous study. The goal of this study was to develop and validate a machine learning-based natural language classifier that can automatically assign the use of intravenous contrast for musculoskeletal MRI protocols based upon the free-text clinical indication of the study, thereby improving efficiency of the protocoling radiologist and potentially decreasing errors. We utilized a deep learning-based natural language classification system from IBM Watson, a question-answering supercomputer that gained fame after challenging the best human players on Jeopardy! in 2011. We compared this solution to a series of traditional machine learning-based natural language processing techniques that utilize a term-document frequency matrix. Each classifier was trained with 1240 MRI protocols plus their respective clinical indications and validated with a test set of 280. Ground truth of contrast assignment was obtained from the clinical record. For evaluation of inter-reader agreement, a blinded second reader radiologist analyzed all cases and determined contrast assignment based on only the free-text clinical indication. In the test set, Watson demonstrated overall accuracy of 83.2% when compared to the original protocol. This was similar to the overall accuracy of 80.2% achieved by an ensemble of eight traditional machine learning algorithms based on a term-document matrix. When compared to the second reader’s contrast assignment, Watson achieved 88.6% agreement. When evaluating only the subset of cases where the original protocol and second reader were concordant (n = 251), agreement climbed further to 90.0%. The classifier was relatively robust to spelling and grammatical errors, which were frequent. Implementation of this automated MR contrast determination system as a clinical decision support tool may save considerable time and effort of the radiologist while potentially decreasing error rates, and require no change in order entry or workflow.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Towards Provable Security in Industrial Control Systems Via Dynamic Protocol Attestation

Industrial control systems (ICSs) increasingly rely on digital technologies vulnerable to cyber attacks. Cyber attackers can infiltrate ICSs and execute malicious actions. Individually, each action seems innocuous. But taken together, they cause the system to enter an unsafe state. These attacks have resulted in dramatic consequences such as physical damage, economic loss, and environmental catastrophes. This paper introduces a methodology that restricts actions using protocols. These protocols only allow safe actions to execute. Protocols are written in a domain specific language we have embedded in an interactive theorem prover (ITP). The ITP enables formal, machine-checked proofs to ensure protocols maintain safety properties. We use dynamic attestation to ensure ICSs conform to their protocol even if an adversary compromises a component. Since protocol conformance prevents unsafe actions, the previously mentioned cyber attacks become impossible. We demonstrate the effectiveness of our methodology using an example from the Fischertechnik Industry 4.0 platform. We measure dynamic attestation's impact on latency and throughput. Our approach is a starting point for studying how to combine formal methods and protocol design to thwart attacks intended to cripple ICSs.

97 MATHEMATICS AND COMPUTING↗

Bis[2-(methacryloyloxy)ethyl] phosphate radiografted into track-etched PVDF for uranium (VI) determination by means of cathodic stripping voltammetry

Here, we report the radiation grafting of bis[2-(methacryloyloxy)ethyl] phosphate (B2MP) through electron-beam onto PVDF films and through swift heavy ions (SHI) irradiations into the pores of track-etched PVDF membranes. Radiolytically produced radicals were studied using EPR. To adapt the radiation grafting protocol inside the nanopores of track-etched membranes, the electron-beam irradiated films at varying monomer concentrations, doses and solvent mixtures were first studied. It was found that track-etched membranes, even after 1 h of chemical treatment, do not require a post-etching irradiation to initiate free-radical polymerization of B2MP from remaining radiationinduced radicals. The presence of functional groups inside the nanopores of the membrane were examined using FTIR and XPS. After exposure of B2MP-g-PVDF membranes to a uranyl solution, XPS was also exploited to evidence of O 2 UO 2 2+ trapping inside the membrane nanoporosity by tracking the presence of U 4f peak. The B2MP-g-PVDF membranes were converted into electrodes by depositing 35 nm of gold on each side through a mask. Detection of ppb concentrations (from 20 to 100 ppb) of uranyl by B2MP-g-PVDF membrane electrodes was demonstrated by means of square wave cathodic stripping voltammetry (SW-CSV). The limit of detection (LOD) was estimated to be 17 ppb (3σ–/ slope).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Digital zero noise extrapolation for quantum error mitigation

Zero-noise extrapolation (ZNE) is an increasingly popular technique for mitigating errors in noisy quantum computations without using additional quantum resources. We review the fundamentals of ZNE and propose several improvements to noise scaling and extrapolation, the two key components in the technique. We introduce unitary folding and parameterized noise scaling. Furthermore, these are digital noise scaling frameworks, i.e. one can apply them using only gate-level access common to most quantum instruction sets. We also study different extrapolation methods, including a new adaptive protocol that uses a statistical inference framework. Benchmarks of our techniques show error reductions of 18X to 24X over non-mitigated circuits and demonstrate ZNE effectiveness at larger qubit numbers than have been tested previously. In addition to presenting new results, this work is a self-contained introduction to the practical use of ZNE by quantum programmers.

quantum computing↗

Getting through to circadian oscillators: why use constant routines?

Overt 24-h rhythmicity is composed of both exogenous and endogenous components, reflecting the product of multiple (periodic) feedback loops with a core pacemaker at their center. Researchers attempting to reveal the endogenous circadian (near 24-h) component of rhythms commonly conduct their experiments under constant environmental conditions. However, even under constant environmental conditions, rhythmic changes in behavior, such as food intake or the sleep-wake cycle, can contribute to observed rhythmicity in many physiological and endocrine variables. Assessment of characteristics of the core circadian pacemaker and its direct contribution to rhythmicity in different variables, including rhythmicity in gene expression, may be more reliable when such periodic behaviors are eliminated or kept constant across all circadian phases. This is relevant for the assessment of the status of the circadian pacemaker in situations in which the sleep-wake cycle or food intake regimes are altered because of external conditions, such as in shift work or jet lag. It is also relevant for situations in which differences in overt rhythmicity could be due to changes in either sleep oscillatory processes or circadian rhythmicity, such as advanced or delayed sleep phase syndromes, in aging, or in particular clinical conditions. Researchers studying human circadian rhythms have developed constant routine protocols to assess the status of the circadian pacemaker in constant behavioral and environmental conditions, whereas this technique is often thought to be unnecessary in the study of animal rhythms. In this short review, the authors summarize constant routine methodology and what has been learned from constant routines and argue that animal and human circadian rhythm researchers should (continue to) use constant routines as a step on the road to getting through to central and peripheral circadian oscillators in the intact organism.

Non-NASA Center↗

Laser microsurgery of higher plant cell walls permits patch-clamp access

Plasma membranes of guard cells in epidermal peels of Vicia faba and Commelina communis can be made accessible to a patch-clamp pipet by removing a small portion (1-3 micrometers in diameter) of the guard cell wall using a microbeam of ultraviolet light generated by a nitrogen laser. Using this laser microsurgical technique, we have measured channel activity across plasma membranes of V. faba guard cells in both cell-attached and isolated patch configurations. Measurements made in the inside-out patch configuration revealed two distinct K(+)-selective channels. Major advantages of the laser microsurgical technique include the avoidance of enzymatic protoplast isolation, the ability to study cell types that have been difficult to isolate as protoplasts or for which enzymatic isolation protocols result in protoplasts not amenable to patch-clamp studies, the maintenance of positional information in single-channel measurements, reduced disruption of cell-wall-mediated signaling pathways, and the ability to investigate intercellular signaling through studies of cells remaining situated within tissue.

Non-NASA Center↗

Ultra Pure Water Cleaning Baseline Study on NASA JSC Astromaterial Curation Gloveboxes

Future sample return missions will require strict protocols and procedures for reducing inorganic and organic contamination in isolation containment systems. In 2012, a baseline study was orchestrated to establish the current state of organic cleanliness in gloveboxes used by NASA JSC astromaterials curation labs [1, 2]. As part of this in-depth organic study, the current curatorial technical support procedure (TSP) 23 was used for cleaning the gloveboxes with ultra pure water (UPW) [3-5]. Particle counts and identification were obtained that could be used as a benchmark for future mission designs that require glovebox decontamination. The UPW baseline study demonstrates that TSP 23 works well for gloveboxes that have been thoroughly degreased. However, TSP 23 could be augmented to provide even better glovebox decontamination. JSC 03243 could be used as a starting point for further investigating optimal cleaning techniques and procedures. DuPont Vertrel XF or other chemical substitutes to replace Freon- 113, mechanical scrubbing, and newer technology could be used to enhance glovebox cleanliness in addition to high purity UPW final rinsing. Future sample return missions will significantly benefit from further cleaning studies to reduce inorganic and organic contamination.

Calaway, Michael J.↗

A framework for ensemble modelling of climate change impacts on lakes worldwide: the ISIMIP Lake Sector

Abstract. Empirical evidence demonstrates that lakes and reservoirs are warming across the globe. Consequently, there is an increased need to project future changes in lake thermal structure and resulting changes in lake biogeochemistry in order to plan for the likely impacts. Previous studies of the impacts of climate change on lakes have often relied on a single model forced with limited scenario-driven projections of future climate for a relatively small number of lakes. As a result, our understanding of the effects of climate change on lakes is fragmentary, based on scattered studies using different data sources and modelling protocols, and mainly focused on individual lakes or lake regions. This has precluded identification of the main impacts of climate change on lakes at global and regional scales and has likely contributed to the lack of lake water quality considerations in policy-relevant documents, such as the Assessment Reports of the Intergovernmental Panel on Climate Change (IPCC). Here, we describe a simulation protocol developed by the Lake Sector of the Inter-Sectoral Impact Model Intercomparison Project (ISIMIP) for simulating climate change impacts on lakes using an ensemble of lake models and climate change scenarios for ISIMIP phases 2 and 3. The protocol prescribes lake simulations driven by climate forcing from gridded observations and different Earth system models under various representative greenhouse gas concentration pathways (RCPs), all consistently bias-corrected on a 0.5∘ × 0.5∘ global grid. In ISIMIP phase 2, 11 lake models were forced with these data to project the thermal structure of 62 well-studied lakes where data were available for calibration under historical conditions, and using uncalibrated models for 17 500 lakes defined for all global grid cells containing lakes. In ISIMIP phase 3, this approach was expanded to consider more lakes, more models, and more processes. The ISIMIP Lake Sector is the largest international effort to project future water temperature, thermal structure, and ice phenology of lakes at local and global scales and paves the way for future simulations of the impacts of climate change on water quality and biogeochemistry in lakes.

58 GEOSCIENCES↗

New loading method for high precision Sm isotope analysis of nuclear materials using thermal ionization mass spectrometry

This work demonstrates an analytical protocol for high precision Sm isotope analysis by thermal ionization mass spectrometry (TIMS) using a Pt activator. Here, the method permits precise measurements of small aliquots (1–20 ng) of Sm on single Re filament using a modified static-total evaporation technique. This study represents the first attempt to use such protocols for Sm isotope analyses while reducing the loading size of Sm for TIMS. The method could potentially be deployed to study geological, meteorites and lunar samples containing low Sm concentrations, to monitor neutron irradiation exposure based on 149,150 Sm, or to measure Sm isotopic composition in other types of nuclear samples.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Robustness of quantum correlation in quantum energy teleportation

In this article, we explore a feedback-control protocol in different quantum field theories (QFTs) to study the quantum correlation in nonunitary evolution of quantum systems. Traditional studies on QFTs focus on quantum entanglement of pure states under the unitary evolution, however, we examine quantum correlation in mixed states using quantum energy teleportation (QET), which is an energy transfer protocol by utilizing ground state entanglement, and introduce quantum discord as a measure. QET involves a midcircuit measurement, which disrupts pure state entanglement. Despite this, our analysis demonstrates that quantum discord maintains the correlation throughout the QET process. We conducted numerical analyses with benchmark models including the Nambu-Jona-Lasinio (NJL) model, revealing that quantum discord consistently acts as an order parameter for phase transitions. The model is extended in a way that it has both the chiral chemical potential and the chemical potential, which are useful to study the phase structures mimicking the chiral imbalance between left- and right- quarks coupled to the chirality density operator. In all cases we studied, the quantum discord behaved as an order parameter of the phase transition. Published by the American Physical Society 2024

Ikeda, Kazuki (ORCID:0000000338212669)↗

SU-F-R-06: Traumatic Brachial Plexus Injury Imaging, Developing a Coherent Clinical Protocol From Literature Review Through Practice

Purpose: Medical Physics teams can now play a critical role to help plan and provide studied approaches for traumatic brachial plexus MR imaging (tbpMRI). This is especially important for coordination with uncommon applications, since it is challenging to select the right modality, parameters, and train technologists on the essential components. For this work, we started with a review of the medical literature, performed crossover/volunteer studies to bring tbpMRI to practice with greater image QC and protocol management. Methods: To the best of our knowledge, we reviewed the known searchable domain for tbpMRI. We found 69 total articles since 2000. Articles were evaluated with our published protocol for literature management (LIMES3). Two physicists and two radiologists condensed the information from all articles into a knowledgebase. Results: The initial literature demonstrated great heterogeneity, which was a sign that this area needed greater consistency. Despite inconsistency and imprecision, we extracted the most relevant targets using our long-term experience with protocol development in MSK. We ran volunteers on six different magnets of various field strengths with multiple receiver coils, and rebuilt a coherent protocol for tbpMRI. Our radiologists rated LIMES3 work as superior. We have received referrals from the ER and have conducted four patient evaluations. Conclusion: Traumatic brachial plexus MRI has great possible benefits for patients. This work supports the complexity of tbpMRI scanning. As this is rarely performed, it requires a more diligent protocol workflow, coordination of caregivers, and education within multiple clinical departments. Choosing the correct imaging exam can be critical, as patients can have significant neuropathy and/or paralysis. The LIMES3 protocol is well liked at our institution, and forms the cornerstone of understanding for our work. Our literature management led to a better clinical protocol creation despite the diffuse and inconclusive information presented in the existing medical literature.

60 APPLIED LIFE SCIENCES↗

SU-F-207-16: CT Protocols Optimization Using Model Observer

Purpose: To quantitatively evaluate the performance of different CT protocols using task-based measures of image quality. This work studies the task of size and the contrast estimation of different iodine concentration rods inserted in head- and body-sized phantoms using different imaging protocols. These protocols are designed to have the same dose level (CTDIvol) but using different X-ray tube voltage settings (kVp). Methods: Different concentrations of iodine objects inserted in a head size phantom and a body size phantom are imaged on a 64-slice commercial CT scanner. Scanning protocols with various tube voltages (80, 100, and 120 kVp) and current settings are selected, which output the same absorbed dose level (CTDIvol). Because the phantom design (size of the iodine objects, the air gap between the inserted objects and the phantom) is not ideal for a model observer study, the acquired CT images are used to generate simulation images with four different sizes and five different contracts iodine objects. For each type of the objects, 500 images (100 x 100 pixels) are generated for the observer study. The observer selected in this study is the channelized scanning linear observer which could be applied to estimate the size and the contrast. The figure of merit used is the correct estimation ratio. The mean and the variance are estimated by the shuffle method. Results: The results indicate that the protocols with 100 kVp tube voltage setting provides the best performance for iodine insert size and contrast estimation for both head and body phantom cases. Conclusion: This work presents a practical and robust quantitative approach using channelized scanning linear observer to study contrast and size estimation performance from different CT protocols. Different protocols at same CTDIvol setting could Result in different image quality performance. The relationship between the absorbed dose and the diagnostic image quality is not linear.

60 APPLIED LIFE SCIENCES↗

On deadlock detection in distributed systems

A hierarchically organized and a distributed protocol for deadlock detection in distributed databases are presented in a previous study Menasce and Muntz (1979). In this paper, it is shown that the distributed protocol is incorrect, and possible remedies are presented. However, the distributed protocol remains impractical because 'condensations' of 'transaction-wait-for' graphs make graph updates difficult to perform. Delayed graph updates cause the occurrence of false deadlocks in this as well as in some other deadlock detection protocols for distributed systems. The performance degradation that results from false deadlocks depends on the characteristics of each protocol.

Gligor, V. D.↗

A systematic strategy for estimating hERG block potency and its implications in a new cardiac safety paradigm

Introduction: hERG block potency is widely used to calculate a drug's safety margin against its torsadogenic potential. Previous studies are confounded by use of different patch clamp electrophysiology protocols and a lack of statistical quantification of experimental variability. Since the new cardiac safety paradigm being discussed by the International Council for Harmonisation promotes a tighter integration of nonclinical and clinical data for torsadogenic risk assessment, a more systematic approach to estimate the hERG block potency and safety margin is needed. Methods: A cross-industry study was performed to collect hERG data on 28 drugs with known torsadogenic risk using a standardized experimental protocol. A Bayesian hierarchical modeling (BHM) approach was used to assess the hERG block potency of these drugs by quantifying both the inter-site and intra-site variability. A modeling and simulation study was also done to evaluate protocol-dependent changes in hERG potency estimates. Results: A systematic approach to estimate hERG block potency is established. The impact of choosing a safety margin threshold on torsadogenic risk evaluation is explored based on the posterior distributions of hERG potency estimated by this method. The modeling and simulation results suggest any potency estimate is specific to the protocol used. Discussion: This methodology can estimate hERG block potency specific to a given voltage protocol. The relationship between safety margin thresholds and torsadogenic risk predictivity suggests the threshold should be tailored to each specific context of use, and safety margin evaluation may need to be integrated with other information to form a more comprehensive risk assessment.

60 APPLIED LIFE SCIENCES↗

An International Laboratory Comparison Study of Volumetric and Gravimetric Hydrogen Adsorption Measurements

In order to determine a material's hydrogen storage potential, capacity measurements must be robust, reproducible, and accurate. Commonly, research reports focus on the gravimetric capacity, and often times the volumetric capacity is not reported. Determining volumetric capacities is not as straight-forward, especially for amorphous materials. This is the first study to compare measurement reproducibility across laboratories for excess and total volumetric hydrogen sorption capacities based on the packing volume. The use of consistent measurement protocols, common analysis, and figure of merits for reporting data in this study, enable the comparison of the results for two different materials. Importantly, the results show good agreement for excess gravimetric capacities amongst the laboratories. Irreproducibility for excess and total volumetric capacities is attributed to real differences in the measured packing volume of the material.

H2 storage↗

Strategies for Distinguishing Abiotic Chemistry from Martian Biochemistry in Samples Returned from Mars

A key goal in the search for evidence of extinct or extant life on Mars will be the identification of chemical biosignatures including complex organic molecules common to all life on Earth. These include amino acids, the monomer building blocks of proteins and enzymes, and nucleobases, which serve as the structural basis of information storage in DNA and RNA. However, many of these organic compounds can also be formed abiotically as demonstrated by their prevalence in carbonaceous meteorites [1]. Therefore, an important challenge in the search for evidence of life on Mars will be distinguishing between abiotic chemistry of either meteoritic or martian origin from any chemical biosignatures from an extinct or extant martian biota. Although current robotic missions to Mars, including the 2011 Mars Science Laboratory (MSL) and the planned 2018 ExoMars rovers, will have the analytical capability needed to identify these key classes of organic molecules if present [2,3], return of a diverse suite of martian samples to Earth would allow for much more intensive laboratory studies using a broad array of extraction protocols and state-of-theart analytical techniques for bulk and spatially resolved characterization, molecular detection, and isotopic and enantiomeric compositions that may be required for unambiguous confirmation of martian life. Here we will describe current state-of-the-art laboratory analytical techniques that have been used to characterize the abundance and distribution of amino acids and nucleobases in meteorites, Apollo samples, and comet- exposed materials returned by the Stardust mission with an emphasis on their molecular characteristics that can be used to distinguish abiotic chemistry from biochemistry as we know it. The study of organic compounds in carbonaceous meteorites is highly relevant to Mars sample return analysis, since exogenous organic matter should have accumulated in the martian regolith over the last several billion years and the analytical techniques previously developed for the study of extraterrestrial materials can be applied to martian samples.

Glavin, D. P.↗

Refinement of Protocols for Measuring the Apparent Optical Properties of Seawater

Ocean color satellite missions, like the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) or the Moderate Resolution Imaging Spectroradiometer (MODIS) projects, are tasked with acquiring a global ocean color data set, validating and monitoring the accuracy and quality of the data, processing the radiometric data into geophysical units using a set of atmospheric and bio-optical algorithms, and distributing the final products to the scientific community. The long-standing requirement of the SeaWiFS Project, for example, is to produce spectral water-leaving radiances, LW(lambda), to within 5% absolute (lambda denotes wavelength) and chlorophyll a concentrations to within 35% (Hooker and Esaias 1993), and most ocean color sensors have the same or similar requirements. Although a diverse set of activities are required to ensure the accuracy requirements are met (Hooker and McClain 2000), the perspective here is with field observations. The accurate determination of upper ocean apparent optical properties (AOPs) is essential for the vicarious calibration of ocean color data and the validation of the derived data products, because the sea-truth measurements are used to evaluate the satellite observations (Hooker and McClain 2000). The uncertainties with in situ AOP measurements have various sources: a) the sampling procedures used in the field, including the environmental conditions encountered; b) the absolute characterization of the radiometers in the laboratory; c) the conversion of the light signals to geophysical units in a processing scheme, and d) the stability of the radiometers in the harsh environment they are subjected to during transport and use. Assuming ideal environmental conditions, so this aspect can be neglected, the SeaWiFS ground-truth uncertainty budget can only be satisfied if each uncertainty is on the order of 1-2%, or what is generally referred to as 1% radiometry. In recent years, progress has been made in estimating the magnitude of some of these uncertainties and in defining procedures for minimizing them. For the SeaWiFS Project, the first step was to convene a workshop to draft the SeaWiFS Ocean Optics Protocols (hereafter referred to as the Protocols). The Protocols initially adhered to the Joint Global Ocean Flux Study (JGOFS) sampling procedures (JGOFS 1991) and defined the standards for optical measurements to be used in SeaWiFS calibration and validation activities (Mueller and Austin 1992). Over time, the Protocols were revised (Mueller and Austin 1995), and then recurringly updated on essentially an annual basis (Mueller 2000, 2002, and 2003) as part of the Sensor Inter-comparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) project. 98

Hooker, Stanford B.↗