Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

NESC Independent Review of the Mars Reconnaissance Orbiter (MRO) Contamination Thermal/Vacuum (T/V) Anomaly Technical Consultation Report

The NESC eras requested by the NASA Jet Propulsion Laboratory (JPL) to conduct an independent review of the Mars Reconnaissance Orbiter (MRO) Thermal/Vacuum (T/V) Anomaly Assessment. Because the anomaly resulted in the surface contamination of the MRO, selected members of the Materials Super Problem Resolution Team (SPRT) and the NASA technical community having technical expertise relative to contamination issues were chosen for the independent review. The consultation consisted of a review of the MRO Project's reported response to the assessment findings, a detailed review of JPL technical assessment final report, and detailed discussions with the JPL assessment team relative to their findings.

Sutter, James K.↗

Contamination of Critical Surfaces from NVR Glove Residues Via Dry Handling and Solvent Cleaning

Gloves are often used to prevent the contamination of critical surfaces during handling. The type of glove chosen for use should be the glove that produces the least amount of non-volatile residue (NVR). This paper covers the analysis of polyethylene, nitrile, latex, vinyl, and polyurethane gloves using the contact transfer and gravimetric determination methods covered in the NASA GSFC work instruction Gravimetric Determination and Contact Transfer of Non-volatile Residue (NVR) in Cleanroom Glove Samples, 541-WI-5330.1.21 and in the ASTM Standard E-1731M-95, Standard Test Method for Gravimetric Determination of Non-Volatile Residue from Cleanroom Gloves. The tests performed focus on contamination of critical surfaces at the molecular level. The study found that for the most part, all of the gloves performed equally well in the contact transfer testing. However, the polyethylene gloves performed the best in the gravimetric determination testing, and therefore should be used whenever solvent contact is a possibility. The nitrile gloves may be used as a substitute for latex gloves when latex sensitivity is an issue. The use of vinyl gloves should be avoided, especially if solvent contact is a possibility. A glove database will be established by Goddard Space Flight Center (GSFC) Code 541 to compile the results from future testing of new gloves and different glove lots.

Sovinski, Marjorie F.↗

Hot rocket plume experiment - Survey and conceptual design

Attention is given to a space-borne engine plume experiment study to fly an experiment which will both verify and quantify the reduced contamination from advanced rhenium-iridium earth-storable bipropellant rockets (hot rockets) and provide a correlation between high-fidelity, in-space measurements and theoretical plume and surface contamination models. The experiment conceptual design is based on survey results from plume and contamination technologists throughout the U.S. With respect to shuttle use, cursory investigations validate Hitchhiker availability and adaptability, adequate remote manipulator system (RMS) articulation and dynamic capability, acceptable RMS attachment capability, adequate power and telemetry capability, and adequate flight altitude and attitude/orbital capability.

Millard, Jerry M.↗

Environmentally compatible hand wipe cleaning solvents

Several solvents of environmental concern have previously been used for hand wipe cleaning of SRB surfaces, including 1,1,1-trichloroethane, perchloroethylene, toluene, xylene, and MEK. USBI determined the major types of surfaces involved, and qualification requirements of replacement cleaning agents. Nineteen environmentally compatible candidates were tested on 33 material substrates with 26 types of potential surface contaminants, involving over 7,000 individual evaluations. In addition to the cleaning performance evaluation, bonding, compatibility, and corrosion tests were conducted. Results showed that one cleaner was not optimum for all surfaces. In most instances, some of the candidates cleaned better than the 1,1,1-trichloroethane baseline control. Aqueous cleaners generally cleaned better, and were more compatible with nonmetallic materials, such as paints, plastics, and elastomers. Organic base cleaners were better on metal surfaces. Five cleaners have been qualified and are now being implemented in SRB hand wipe cleaning operations.

Clayton, Catherine P.↗

Impact of laser-contaminant interaction on the performance of the protective capping layer of 1w high-reflection mirror coatings

In this paper, high dielectric constant multilayer coatings are commonly used on high-reflection mirrors for high-peak-power laser systems because of their high laser-damage resistance. However, surface contaminants often lead to damage upon laser exposure, thus limiting the mirror’s lifetime and performance. One plausible approach to improve the overall mirror resistance against laser damage, including that induced by laser-contaminant coupling, is to coat the multilayers with a thin protective capping (absentee) layer on top of the multilayer coatings. An understanding of the underlying mechanism by which laser-particle interaction leads to capping layer damage is important for the rational design and selection of capping materials of high-reflection multilayer coatings. In this paper, we examine the responses of two candidate capping layer materials, made of SiO 2 and Al 2 O 3 , over silica-hafnia multilayer coatings. These are exposed to a single oblique shot of a 1053 nm laser beam (fluence ~10 J/cm 2 , pulse length 14 ns), in the presence of Ti particles on the surface. We find that the two capping layers show markedly different responses to the laser-particle interaction. The Al 2 O 3 cap layer exhibits severe damage, with the capping layer becoming completely delaminated at the particle locations. The SiO 2 capping layer, on the other hand, is only mildly modified by a shallow depression. Combining the observations with optical modeling and thermal/mechanical calculations, we argue that a high-temperature thermal field from plasma generated by the laser-particle interaction above a critical fluence is responsible for the surface modification of each capping layer. The great difference in damage behavior is mainly attributed to the large disparity in the thermal expansion coefficient of the two capping materials, with that of Al 2 O 3 layer being about 15 times greater than that of SiO 2 .

36 MATERIALS SCIENCE↗

Optical Spectroscopy of New Materials

Composites are currently used for a rapidly expanding number of applications including aircraft structures, rocket nozzles, thermal protection of spacecraft, high performance ablative surfaces, sports equipment including skis, tennis rackets and bicycles, lightweight automobile components, cutting tools, and optical-grade mirrors. Composites are formed from two or more insoluble materials to produce a material with superior properties to either component. Composites range from dispersion-hardened alloys to advanced fiber-reinforced composites. UV/VIS and FTIR spectroscopy currently is used to evaluate the bonding between the matrix and the fibers, monitor the curing process of a polymer, measure surface contamination, characterize the interphase material, monitor anion transport in polymer phases, characterize the void formation (voids must be minimized because, like cracks in a bulk material, they lead to failure), characterize the surface of the fiber component, and measure the overall optical properties for energy balances.

White, Susan M.↗

Molecular Dynamics Investigation of the Structural and Mechanical Properties of Off-Stoichiometric Epoxy Resins

Molecular dynamic (MD) simulations were performed to compute the mechanical properties of off-stoichiometric epoxy resins as a function of hardener/epoxy mixture ratio (r). Properties were characterized in relation to their microscopic structures. Such resins have been used recently for adhesive-free bonding of large-scale composite structures using the co-curing-ply method. In this process, two partially precured composite panels with hardener-poor (HP) off-stoichiometric resins are coupled with ply(ies) of complementary hardener-rich (HR) formulations and then cured simultaneously. This bonding process has the potential to produce reliable and certifiable composite joints without the need for additional fasteners, which are often required for many conventional bonding methods because even small amounts of contamination can cause a weak bond. The reflow and mixing of the HP/HR resin in this bonding process result in a joint with no discernable interface that should not be susceptible to surface contamination. However, incomplete mixing of the two offset resins may result in chemical heterogeneity of the cured polymeric joint. Thus, different r values may be obtained across the joint. Classical MD simulations were performed to compute the Young’s modulus of polymers with different r values and correlate their properties to network structures. High stiffness was associated with molecular packing due to chemical crosslinking, leading to a single network structure. Moreover, the networks became denser as the ratio approached the stoichiometric value r = 1. Thus, the r = 1 systems were single clusters, with high stiffness, high molecular weight, and a high degree of crosslinking. Structural properties such as radius of gyration and mean square displacement were determined to investigate the variation in the stiffness with respect to r. This MD simulation study was validated with experimental measurements.

Chang Woon Jang↗

Surface oxidation of GaN(0001): Nitrogen plasma-assisted cleaning for ultrahigh vacuum applications

The cleaning of metal-organic vapor-phase epitaxial GaN(0001) template layers grown on sapphire has been investigated. Different procedures, performed under ultrahigh vacuum conditions, including degassing and exposure to active nitrogen from a radio frequency nitrogen plasma source have been compared. For this purpose, x-ray photoelectron spectroscopy, reflection high-energy electron diffraction, and scanning tunneling microscopy have been employed in order to assess chemical as well as structural and morphological surface properties. Initial degassing at 600 °C under ultrahigh vacuum conditions only partially eliminates the surface contaminants. In contrast to plasma assisted nitrogen cleaning at temperatures as low as 300 °C, active-nitrogen exposure at temperatures as high as 700 °C removes the majority of oxide species from the surface. However, extended high-temperature active-nitrogen cleaning leads to severe surface roughening. Optimum results regarding both the removal of surface oxides as well as the surface structural and morphological quality have been achieved for a combination of initial low-temperature plasma-assisted cleaning, followed by a rapid nitrogen plasma-assisted cleaning at high temperature.

36 MATERIALS SCIENCE↗

Removing Contamination From Genesis Sapphire Collectors By Polishing

The Array Collectors of the Genesis spacecraft collected bulk solar wind (SW), as well as three subsets of SW (fast, slow, and coronal mass ejection) in a variety of materials. In all cases the SW implant peaked within < 0.2 microns of the surface. So, when the sample return capsule crashed on landing, cleaning the surfaces for analysis became an extremely difficult, but imperative, task. One collector material was “sapphire”, commercial single crystal corundum. Only ~7.7% of the Genesis Array collectors were sapphire (SAP) but a much higher percentage survived the crash. In fact, surviving bulk SW sapphire collectors have an average area ~10x that of their silicon counterparts since SAP is physically tough, and hard (MOHS 9, by definition) as well as is chemically inert. So, SAP is a good candidate for analytical techniques for measuring SW that require clean areas larger than a millimeter; e.g., synchrotron TXRF and INAA. It is also possible to measure SW in SAP using laser ablation and secondary ion mass spectrometry (SIMS) and, recently, more researchers are choosing to analyze sapphire. Thus, removing surface contamination from SAP could enable many research projects. This report extends the task presented in Schmeling et al. ([4]) that used polishing compounds to remove contamination from Genesis sapphire. It focuses on how polishing with their two top candidates (colloidal silica and cerium oxide) affects the SW layer in SAP.

Genesis solar wind↗

Film growth, adsorption and desorption kinetics of indigo on SiO{sub 2}

Organic dyes have recently been discovered as promising semiconducting materials, attributable to the formation of hydrogen bonds. In this work, the adsorption and desorption behavior, as well as thin film growth was studied in detail for indigo molecules on silicon dioxide with different substrate treatments. The material was evaporated onto the substrate by means of physical vapor deposition under ultra-high vacuum conditions and was subsequently studied by Thermal Desorption Spectroscopy (TDS), Auger Electron Spectroscopy, X-Ray Diffraction, and Atomic Force Microscopy. TDS revealed initially adsorbed molecules to be strongly bonded on a sputter cleaned surface. After further deposition a formation of dimers is suggested, which de-stabilizes the bonding mechanism to the substrate and leads to a weakly bonded adsorbate. The dimers are highly mobile on the surface until they get incorporated into energetically favourable three-dimensional islands in a dewetting process. The stronger bonding of molecules within those islands could be shown by a higher desorption temperature. On a carbon contaminated surface no strongly bonded molecules appeared initially, weakly bonded monomers rather rearrange into islands at a surface coverage that is equivalent to one third of a monolayer of flat-lying molecules. The sticking coefficient was found to be unity on both substrates. The desorption energies from carbon covered silicon dioxide calculated to 1.67 ± 0.05 eV for multilayer desorption from the islands and 0.84 ± 0.05 eV for monolayer desorption. Corresponding values for desorption from a sputter cleaned surface are 1.53 ± 0.05 eV for multilayer and 0.83 ± 0.05 eV for monolayer desorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Corrective Action Investigation Plan for Corrective Action Unit 576: Miscellaneous Radiological Sites and Debris Nevada National Security Site, Nevada, Revision 0

Corrective Action Unit (CAU) 576 is located in Areas 2, 3, 5, 8, and 9 of the Nevada National Security Site, which is approximately 65 miles northwest of Las Vegas, Nevada. CAU 576 is a grouping of sites where there has been a suspected release of contamination associated with nuclear testing. This document describes the planned investigation of CAU 576, which comprises the following corrective action sites (CASs): 00-99-01, Potential Source Material; 02-99-12, U-2af (Kennebec) Surface Rad-Chem Piping; 03-99-20, Area 3 Subsurface Rad-Chem Piping; 05-19-04, Frenchman Flat Rad Waste Dump ; 09-99-08, U-9x (Allegheny) Subsurface Rad-Chem Piping; 09-99-09, U-9its u24 (Avens-Alkermes) Surface Contaminated Flex Line These sites are being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend corrective action alternatives (CAAs). Additional information will be obtained by conducting a corrective action investigation before evaluating CAAs and selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible evaluation of viable CAAs that will be presented in the Corrective Action Decision Document (CADD).

54 ENVIRONMENTAL SCIENCES↗

OGO-6 gas-surface energy transfer experiment

The kinetic energy flux of the upper atmosphere was analyzed using OGO-6 data. Energy transfer between 10 microwatts/sq cm and 0.1 W/sq cm was measured by short-term frequency changes of temperature-sensitive quartz crystals used in the energy transfer probe. The condition of the surfaces was continuously monitored by a quartz crystal microbalance to determine the effect surface contamination had on energy accommodation. Results are given on the computer analysis and laboratory tests performed to optimize the operation of the energy transfer probe. Data are also given on the bombardment of OGO-6 surfaces by high energy particles. The thermoelectrically-cooled quartz crystal microbalance is described in terms of its development and applications.

Mckeown, D.↗

Dust protection for environmental control and life support systems in the lunar environment

Lunar dust is pervasive, and requirements for dust protection will affect both hardware design and operations planning for lunar surface systems. On Earth, mechanical problems caused by particulates include erosive and abrasive effects, clogging of mechanical equipment, and impairment of seals and bonds. In addition, dust tends to degrade the heat rejection properties of contaminated surfaces. All these effects have been observed on the lunar surface as well. This paper discusses the potential applicability of current dust protection methods to the problem of dust protection for the environmental control and life support (ECLS) systems of a lunar base, and highlights areas where development may be necessary. A review of dust problems experienced during the Apollo missions and of additional, ground-based experience with lunar dust provides a baseline for identifying operations and areas where dust may be expected to affect the ECLS systems. Current Earth-based methods of dust protection are identified and the impact of differences between the Earth and lunar environments on these methods is evaluated. Finally, integration of dust protection equipment with ECLS systems equipment is discussed.

Fuhs, Susan↗

Auger spectroscopic examination of MgF2-coated Al mirrors before and after UV irradiation

Magnesium fluoride protected Al films were studied since these mirrors are commonly used in astronomical instruments whenever a highly reflecting optical surface is required in the wavelength region from 1100 A to 2000 A. Freshly prepared samples of evaporated Al + 250-A thick MgF2 on glass were analyzed by Auger electron spectroscopy in conjunction with surface erosion by Ar(+) ion bombardment before and after UV irradiation. The analysis showed that a very thin layer of surface contamination and not bulk photolysis in the MgF2 film was reponsible for the irradiation-induced reflectance loss. Postirradiation polishing with a mild calcium carbonate abrasive can restore a mirror's reflectance by removing the photolyzed surface film without disturbing the MgF2 layer.

Heaney, J. B.↗

Surface and subsurface characterization of laser-interference structured Ti6Al4V

Ti6Al4V specimens were exposed to high-energy laser pulses of 1.24 J/cm 2 fluences per pulse using a two-beam optical configuration to attain laser-interference. In addition to the formation of periodic surface textures by laser-interference, scanning electron microscope (SEM) images demonstrated several microstructural changes on the surface processed. Moreover, the surface and subsurface of Ti6Al4V specimens were characterized for the as-received and laser-interference processed conditions using x-ray photoelectron spectroscopy (XPS) and electron energy dispersive spectroscopy (EDS). The XPS data showed that this laser technique is effective at removal of surface contaminants for Ti6Al4V. The XPS analysis also revealed the formation of an oxy-nitride layer on the laser treated material. Finally, the microstructure analysis indicates that grain refinement, dendrite and twin structures were found near the surface due to laser processing.

36 MATERIALS SCIENCE↗

Cleaning Genesis Mission Payload for Flight with Ultra-Pure Water and Assembly in ISO Class 4 Environment

Genesis mission to capture and return to Earth solar wind samples had very stringent contamination control requirements in order to distinguish the solar atoms from terrestrial ones. Genesis mission goals were to measure solar composition for most of the periodic table, so great care was taken to avoid particulate contamination. Since the number 1 and 2 science goals were to determine the oxygen and nitrogen isotopic composition, organic contamination was minimized by tightly controlling offgassing. The total amount of solar material captured in two years is about 400 micrograms spread across one sq m. The contamination limit requirement for each of C, N, and O was <1015 atoms/sq cm. For carbon, this is equivalent to 10 ng/cm2. Extreme vigilance was used in pre-paring Genesis collectors and cleaning hardware for flight. Surface contamination on polished silicon wafers, measured in Genesis laboratory is approximately 10 ng/sq cm.

Allton, Judith H.↗

Characterization of polymeric films subjected to lithium ion beam irradiation

Two different polymeric materials that are candidate materials for use as binders for mixed uranium–plutonium oxide nuclear fuel pellets were subjected to Li ion beam irradiation, in order to simulate intense alpha irradiation. The materials (a polyethylene glycol 8000 and a microcrystalline wax) were then analyzed using a combination of mass spectrometry (MS) approaches and X-ray photoelectron spectroscopy (XPS). Samples of the irradiated PEG materials were dissolved in H2O and then analyzed using electrospray ionization-MS, which showed the formation of a series of small oligomers in addition to intact large PEG oligomers. The small oligomers were likely formed by radiation-induced homolytic scissions of the C–O and C–C bonds, which furnish radical intermediates that react by radical recombination with Hradical dot and OHradical dot. Surface analysis using SIMS revealed a heterogeneous surface that contained not only PEG-derived polymers, but also hydrocarbon-based entities that are likely surface contaminants. XPS of the irradiated PEG samples indicated the emergence of different carbon species, with peak shifts suggesting the presence of sp2 carbon atoms. Analysis of the paraffinic film using XPS showed the emergence of oxygen on the surface of the sample, and also a broadening and shifting of the C1s peak, demonstrating a change in the chemistry on the surface. The paraffinic film did not dissolve in either H2O or a H2O–methanol solution, and hence the bulk of the material could not be analyzed using electrospray. However a series of oligomers was leached from the bulk material that produced ion series in the ESI-MS analyses that were identified octylphenyl ethoxylate oligomers. Upon Li ion bombardment, these shifted to a lower average molecular weight, but more importantly showed the emergence of three new ion series that are being formed as a result of radiation damage. Surface analysis of the paraffinic polymers using SIMS produced spectra that were wholly dominated by hydrocarbon ion series, and no difference was observed between unirradiated and irradiated samples. The studies demonstrate that for the PEG-based polymers, direct evidence for radiolytic scission can be observed using ESI-MS, and suggests that both radiolytic pathways and efficiencies as a function of dose should be measurable by calibrating instrument response to the small oligomeric degradation products.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗