Search NASA⌕ Search

SEARCH · Search NASA

Results for “task”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Dosimetric effects caused by couch tops and immobilization devices: Report of AAPM Task Group 176

The dosimetric impact from devices external to the patient is a complex combination of increased skin dose, reduced tumor dose, and altered dose distribution. Although small monitor unit or dose corrections are routinely made for blocking trays, ion chamber correction factors, e.g., accounting for temperature and pressure, or tissue inhomogeneities, the dose perturbation of the treatment couch top or immobilization devices is often overlooked. These devices also increase skin dose, an effect which is also often ignored or underestimated. These concerns have grown recently due to the increased use of monolithic carbon fiber couch tops which are optimal for imaging for patient position verification but cause attenuation and increased skin dose compared to the “tennis racket” style couch top they often replace. Also, arc delivery techniques have replaced stationary gantry techniques which cause a greater fraction of the dose to be delivered from posterior angles. A host of immobilization devices are available and used to increase patient positioning reproducibility, and these also have attenuation and skin dose implications which are often ignored. This report of Task Group 176 serves to present a survey of published data that illustrates the magnitude of the dosimetric effects of a wide range of devices external to the patient. The report also provides methods for modeling couch tops in treatment planning systems so the physicist can accurately compute the dosimetric effects for indexed patient treatments. Both photon and proton beams are considered. A discussion on avoidance of high density structures during beam planning is also provided. An important aspect of this report are the recommendations the authors make to clinical physicists, treatment planning system vendors, and device vendors on how to make measurements of surface dose and attenuation and how to report these values. For the vendors, an appeal is made to work together to provide accurate couch top models in planning systems.

60 APPLIED LIFE SCIENCES↗

Radiation dosimetry in digital breast tomosynthesis: Report of AAPM Tomosynthesis Subcommittee Task Group 223

The radiation dose involved in any medical imaging modality that uses ionizing radiation needs to be well understood by the medical physics and clinical community. This is especially true of screening modalities. Digital breast tomosynthesis (DBT) has recently been introduced into the clinic and is being used for screening for breast cancer in the general population. Therefore, it is important that the medical physics community have the required information to be able to understand, estimate, and communicate the radiation dose levels involved in breast tomosynthesis imaging. For this purpose, the American Association of Physicists in Medicine Task Group 223 on Dosimetry in Tomosynthesis Imaging has prepared this report that discusses dosimetry in breast imaging in general, and describes a methodology and provides the data necessary to estimate mean breast glandular dose from a tomosynthesis acquisition. In an effort to maximize familiarity with the procedures and data provided in this Report, the methodology to perform the dose estimation in DBT is based as much as possible on that used in mammography dose estimation.

60 APPLIED LIFE SCIENCES↗

SU-E-P-22: AAPM Task Group 263 Tackling Standardization of Nomenclature for Radiation Therapy

Purpose: There is growing recognition of need for increased clarity and consistency in the nomenclatures used for body and organ structures, DVH metrics, toxicity, dose and volume units, etc. Standardization has multiple benefits; e.g. facilitating data collection for clinical trials, enabling the pooling of data between institutions, making transfers (i.e. hand-offs) between centers safer, and enabling vendors to define “default” settings. Towards this goal, the American Association of Physicists in Medicine (AAPM) formed a task group (TG263) in July of 2014, operating under the Work Group on Clinical Trials to develop consensus statements. Guiding principles derived from the investigation and example nomenclatures will be presented for public feedback. Methods: We formed a multi-institutional and multi-vendor collaborative group of 39 physicists, physicians and others involved in clinical use and electronic transfer of information. Members include individuals from IROC, NRG, IHE-RO, DICOM WG-7, ASTRO and EORTC groups with overlapping interests to maximize the quality of the consensus and increase the likelihood of adoption. Surveys of group and NRG members were used to define current nomenclatures and requirements. Technical requirements of vendor systems and the proposed DICOM standards were examined. Results: There is a marked degree of inter and intra institutional variation in current approaches, resulting from inter-vendor differences in capabilities, clinic specific conceptualizations and inconsistencies. Using a consensus approach, the group defined optimal formats for the naming of targets and normal structures. A formal objective assessment of 13 existing clinically-used software packages show that all had capabilities to accommodate these recommended nomenclatures. Conclusions: A multi-stakeholder effort is making significant steps forward in developing a standard nomenclature that will work across platforms. Our current working list includes > 550 structures. Outreach efforts are ongoing to ensure broader participation in evaluating and testing the principles as they are developed by TG263.

60 APPLIED LIFE SCIENCES↗

SU-E-T-181: Clinical Implementation of Task Group 176

Purpose: The implementation of TG-176 with regards to immobilization devices and couch tops as they effect dosimetric treatment planning. Methods: The external devices used clinically were scanned to measure their HU values. Plans were created in the Eclipse treatment planning system (TPS) using these devices, one that accounted for the correct HU value of the each device and another that did not include the device as a structure. A dose subtraction was performed between the two plans to evaluate the dosimetric differences. The metrics used for evaluation included attenuation and surface dose. Plan parameters were varied to evaluate the impact of the devices in different clinical scenarios. Results: While the exact HU values of our results are clinic-dependent, the protocol being implemented is widely applicable. We recommend a four step process for implementing this task group. First, physics should scan each treatment device to determine accurate HU values. Second, CT therapists should include in the setup note which table top was used during patient CT simulation and are asked to make immobilization devices as uniform in thickness as possible. Therapists should also index the devices whenever possible so beam will traverse the same area of the device. Third, the dosimetrist should manually correct the HU value for any external device, including the couch. For H&N cases, the rails must be removed from the couch structure. When rails are used during treatments, it is important to make note of their exact position in the setup notes. Finally, physicians should be made aware that there could be changes in surface doses depending on whether or not immobilization devices or couch tops are in the beam path. Conclusion: The protocol outlined above was implemented to reduce the errors that arise from ignoring effects of external devices, thus ensuring safer, more accurate patient treatments.

60 APPLIED LIFE SCIENCES↗

TU-EF-204-11: Impact of Using Multi-Slice Training Sets On the Performance of a Channelized Hotelling Observer in a Low-Contrast Detection Task in CT

Purpose: To investigate using multiple CT image slices from a single acquisition as independent training images for a channelized Hotelling observer (CHO) model to reduce the number of repeated scans for CHO-based CT image quality assessment. Methods: We applied a previously validated CHO model to detect low contrast disk objects formed from cross-sectional images of three epoxy-resin-based rods (diameters: 3, 5, and 9 mm; length: ∼5cm). The rods were submerged in a 35x 25 cm2 iodine-doped water filled phantom, yielding-15 HU object contrast. The phantom was scanned 100 times with and without the rods present. Scan and reconstruction parameters include: 5 mm slice thickness at 0.5 mm intervals, 120 kV, 480 Quality Reference mAs, and a 128-slice scanner. The CHO’s detectability index was evaluated as a function of factors related to incorporating multi-slice image data: object misalignment along the z-axis, inter-slice pixel correlation, and number of unique slice locations. In each case, the CHO training set was fixed to 100 images. Results: Artificially shifting the object’s center position by as much as 3 pixels in any direction relative to the Gabor channel filters had insignificant impact on object detectability. An inter-slice pixel correlation of >∼0.2 yielded positive bias in the model’s performance. Incorporating multi-slice image data yielded slight negative bias in detectability with increasing number of slices, likely due to physical variations in the objects. However, inclusion of image data from up to 5 slice locations yielded detectability indices within measurement error of the single slice value. Conclusion: For the investigated model and task, incorporating image data from 5 different slice locations of at least 5 mm intervals into the CHO model yielded detectability indices within measurement error of the single slice value. Consequently, this methodology would Result in a 5-fold reduction in number of image acquisitions. This project was supported by National Institutes of Health grants R01 EB017095 and U01 EB017185 from the National Institute of Biomedical Imaging and Bioengineering.

60 APPLIED LIFE SCIENCES↗

SU-D-206-06: Task-Specific Optimization of Scintillator Thickness for CMOS-Detector Based Cone-Beam Breast CT

Purpose: To optimize the cesium iodide (CsI:Tl) scintillator thickness in a complimentary metal-oxide semiconductor (CMOS)-based detector for use in dedicated cone-beam breast CT. Methods: The imaging task considered was the detection of a microcalcification cluster comprising six 220µm diameter calcium carbonate spheres, arranged in the form of a regular pentagon with 2 mm spacing on its sides and a central calcification, similar to that in ACR-recommended mammography accreditation phantom, at a mean glandular dose of 4.5 mGy. Generalized parallel-cascades based linear systems analysis was used to determine Fourier-domain image quality metrics in reconstructed object space, from which the detectability index inclusive of anatomical noise was determined for a non-prewhitening numerical observer. For 300 projections over 2π, magnification-associated focal-spot blur, Monte Carlo derived x-ray scatter, K-fluorescent emission and reabsorption within CsI:Tl, CsI:Tl quantum efficiency and optical blur, fiberoptic plate transmission efficiency and blur, CMOS quantum efficiency, pixel aperture function and additive noise, and filtered back-projection to isotropic 105µm voxel pitch with bilinear interpolation were modeled. Imaging geometry of a clinical prototype breast CT system, a 60 kV Cu/Al filtered x-ray spectrum from 0.3 mm focal spot incident on a 14 cm diameter semi-ellipsoidal breast were used to determine the detectability index for 300–600 µm thick (75µm increments) CsI:Tl. The CsI:Tl thickness that maximized the detectability index was considered optimal. Results: The limiting resolution (10% modulation transfer function, MTF) progressively decreased with increasing CsI:Tl thickness. The zero-frequency detective quantum efficiency, DQE(0), in projection space increased with increasing CsI:Tl thickness. The maximum detectability index was achieved with 525µm thick CsI:Tl scintillator. Reduced MTF at mid-to-high frequencies for 600µm thick CsI:Tl lowered the detectability index than 525µm CsI:Tl. Conclusion: For the x-ray spectrum and imaging conditions considered, a 525µm thick CsI:Tl scintillator integrated with the CMOS detector is optimal for detecting microcalcification cluster. Funding support: Supported in part by NIH R01 CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or the NCI. Disclosures: SV, GV and AK - Research collaboration, Koning Corp., West Henrietta, NY.

60 APPLIED LIFE SCIENCES↗

TU-D-201-02: Medical Physics Practices for Plan and Chart Review: Results of AAPM Task Group 275 Survey

Purpose: AAPM Task Group (TG) 275 is charged with developing riskbased guidelines for plan and chart review clinical processes. As part of this work an AAPM-wide survey was conducted to gauge current practices. Methods: The survey consisted of 103 multiple-choice questions covering the following review processes for external beam including protons: 1) Initial Plan Check, 2) On-Treatment and 3) End-of-Treatment Chart Check. The survey was designed and validated by TG members with the goal of providing an efficient and easy response process. The survey, developed and deployed with the support of AAPM headquarters, was released to all AAPM members who have self-reported as working in the radiation oncology field and it was kept open for 7 weeks. Results: There are an estimated 4700 eligible participants. At the time of writing, 962 completed surveys have been collected with an average completion time of 24 minutes. Participants are mainly from community hospitals (40%), academicaffiliated hospitals (31%) and free-standing clinics (18%). Among many other metrics covered on the survey, results so far indicate that manual review is an important component on the plan and chart review process (>90%) and that written procedures and checklists are widely used (>60%). However, the details of what is reviewed or checked are fairly heterogeneous among the sampled medical physics community. Conclusion: The data gathered from the survey gauging current practices will be used by TG 275 to develop benchmarks and recommendations for the type and extent of checks to perform effective physics plan and chart review processes.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-DE-207B-05: Measuring Spatial Resolution in Digital Breast Tomosynthesis: Update of AAPM Task Group 245

Purpose: Spatial resolution in digital breast tomosynthesis (DBT) is affected by inherent/binned detector resolution, oblique entry of x-rays, and focal spot size/motion; the limited angular range further limits spatial resolution in the depth-direction. While DBT is being widely adopted clinically, imaging performance metrics and quality control protocols have not been standardized. AAPM Task Group 245 on Tomosynthesis Quality Control has been formed to address this deficiency. Methods: Methods of measuring spatial resolution are evaluated using two prototype quality control phantoms for DBT. Spatial resolution in the detector plane is measured in projection and reconstruction domains using edge-spread function (ESF), point-spread function (PSF) and modulation transfer function (MTF). Spatial resolution in the depth-direction and effective slice thickness are measured in the reconstruction domain using slice sensitivity profile (SSP) and artifact spread function (ASF). An oversampled PSF in the depth-direction is measured using a 50 µm angulated tungsten wire, from which the MTF is computed. Object-dependent PSF is derived and compared with ASF. Sensitivity of these measurements to phantom positioning, imaging conditions and reconstruction algorithms is evaluated. Results are compared from systems of varying acquisition geometry (9–25 projections over 15–60°). Dependence of measurements on feature size is investigated. Results: Measurements of spatial resolution using PSF and LSF are shown to depend on feature size; depth-direction spatial resolution measurements are shown to similarly depend on feature size for ASF, though deconvolution with an object function removes feature size-dependence. A slanted wire may be used to measure oversampled PSFs, from which MTFs may be computed for both in-plane and depth-direction resolution. Conclusion: Spatial resolution measured using PSF is object-independent with sufficiently small object; MTF is object-independent. Depth-direction spatial resolution may be measured directly using MTF or indirectly using ASF or SSP as surrogate measurements. While MTF is object-independent, it is invalid for nonlinear reconstructions.

60 APPLIED LIFE SCIENCES↗

Improving Uintah's Scalability Through the Use of Portable Kokkos-Based Data Parallel Tasks

The University of Utah’s Carbon Capture Multidisciplinary Simulation Center (CCMSC) is using the Uintah Computational Framework to predict performance of a 1000 MWe ultra-supercritical clean coal boiler. The center aims to utilize the Intel Xeon Phi-based DOE systems, Theta and Aurora, through the Aurora Early Science Program by using the Kokkos C++ library to enable node-level performance portability. This paper describes infrastructure advancements and portability improvements made possible by the integration of Kokkos within Uintah. This integration marks a step towards consolidating Uintah’s MPI+PThreads and MPI+CUDA hybrid parallelism approaches into a single MPI+Kokkos approach. Scalability results are presented that compare serial and data parallel task execution models for a challenging radiative heat transfer calculation, central to the center’s predictive boiler simulations. Here, these results demonstrate both good strong-scaling characteristics to 256 Knights Landing (KNL) processors on the NSF Stampede system, and show the KNL-based calculation to compete with prior GPU-based results for the same calculation.

97 MATHEMATICS AND COMPUTING↗

A Compound Data Poisoning Technique with Significant Adversarial Effects on Transformer-based Sentiment Classification Tasks

Transformer-based models have demonstrated much success in various natural language processing tasks. However, they are often vulnerable to adversarial attacks, such as data poisoning, which can intentionally fool the model into generating incorrect results. In this article, we present a novel, compound variant of a data poisoning attack on a transformer-based model that maximizes the poisoning effect while minimizing the scope of poisoning. Here we do so by combining the established data poisoning technique (label flipping) with a novel adversarial artifact selection and insertion technique aimed at minimizing detectability and the scope of the poisoning footprint. We find that by using a combination of these two techniques, we achieve a state-of-the-art attack success rate of approximately 90% while poisoning only 0.5% of the original training set, thus minimizing the scope and detectability of the poisoning action. These findings have the potential to advance the development of better data poisoning detection methods.

97 MATHEMATICS AND COMPUTING↗

DMS Capture Task Manager

The DMS Capture Task Manager is a part of PRISM, the Proteomics Research Information and Management System. The capture manager processes instrument data files, copying them from the instrument to storage servers, validating the data, creating QC graphics, and pushing the data into MyEMSL. Plugin DLLs implement the processing details for each tool.

Gibbons, Bryson↗

PaRSEC: Scalability, flexibility, and hybrid architecture support for task-based applications in ECP

This paper highlights the most significant enhancements made to PaRSEC, a scalable task-based runtime system designed for hybrid machines, during the Exascale Computing Project (ECP). The enhancements focus on expanding the capabilities of PaRSEC to address the evolving landscape of parallel computing. Notable achievements include the integration of support for three major types of accelerators (NVIDIA, AMD, and Intel GPUs), the refinement and increased flexibility of the communication subsystem, and the introduction of new programming interfaces tailored for irregular applications. Additionally, the project resulted in the development of powerful debugging and performance analysis tools aimed at assisting users in understanding and optimizing their applications. We present a comprehensive demonstration of these advancements through a series of benchmarks and applications within ECP and beyond, thereby showcasing the enhanced capabilities of PaRSEC across the diverse architectures within the ECP, providing valuable insights into the runtime system’s adaptability and performance across varied computing environments.

Bouteiller, Aurelien↗

Task 5 Field Scale Stress Modeling Scripts and Data

Project data and Matlab scripts for Task 5 of the project “A Non-Invasive Approach for Elucidating the Spatial Distribution of In Situ Stress in Deep Subsurface Geologic Formations Considered for CO2 Storage”. Project includes the static earth models, grids and other data used for simulation and calibration of the two case studies addressed in the project, referred to herein as the “FutureGen2” model (Illinois) and the “Perch” model (Otsego county, Michigan). Large Dataset, please contact EDXSupport@netl.doe.gov

FutureGen2↗

LED Surgical Task Lighting Scoping Study: A Hospital Energy Alliance Project

Tungsten-halogen (halogen) lamps have traditionally been used to light surgical tasks in hospitals, even though they are in many respects ill-suited to the application due to the large percentage of radiant energy outside the visible spectrum and issues with color rendering/quality. Light-emitting diode (LED) technology offers potential for adjustable color and improved color rendition/quality, while simultaneously reducing side-effects from non-visible radiant energy. It also has the potential for significant energy savings, although this is a fairly narrow application in the larger commercial building energy use sector. Based on analysis of available products and Hospital Energy Alliance member interest, it is recommended that a product specification and field measurement procedure be developed for implementation in demonstration projects.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

IEA Wind Task 26 - Multi-national Case Study of the Financial Cost of Wind Energy: Work Package 1 Final Report

The lifetime cost of wind energy is comprised of a number of components including the investment cost, operation and maintenance costs, financing costs, and annual energy production. Accurate representation of these cost streams is critical in estimating a wind plant's cost of energy. Some of these cost streams will vary over the life of a given project. From the outset of project development,investors in wind energy have relatively certain knowledge of the plant's lifetime cost of wind energy. This is because a wind energy project's installed costs and mean wind speed are known early on, and wind generation generally has low variable operation and maintenance costs, zero fuel cost, and no carbon emissions cost. Despite these inherent characteristics, there are wide variations in thecost of wind energy internationally, which is the focus of this report. Using a multinational case-study approach, this work seeks to understand the sources of wind energy cost differences among seven countries under International Energy Agency (IEA) Wind Task 26 - Cost of Wind Energy. The participating countries in this study include Denmark, Germany, the Netherlands, Spain, Sweden,Switzerland, and the United States. Due to data availability, onshore wind energy is the primary focus of this study, though a small sample of reported offshore cost data is also included.

17 WIND ENERGY↗

Carbon Issues Task Force Report for the Idaho Strategic Energy Alliance

The Carbon Issues Task Force has the responsibility to evaluate emissions reduction and carbon offset credit options, geologic carbon sequestration and carbon capture, terrestrial carbon sequestration on forest lands, and terrestrial carbon sequestration on agricultural lands. They have worked diligently to identify ways in which Idaho can position itself to benefit from potential carbon-related federal legislation, including identifying opportunities for Idaho to engage in carbon sequestration efforts, barriers to development of these options, and ways in which these barriers can be overcome. These are the experts to which we will turn when faced with federal greenhouse gas-related legislation and how we should best react to protect and provide for Idaho’s interests. Note that the conclusions and recommended options in this report are not intended to be exhaustive, but rather form a starting point for an informed dialogue regarding the way-forward in developing Idaho energy resources.

99 GENERAL AND MISCELLANEOUS↗

U.S. Transport Task Force 2010

The Transport Task Force (TTF) Meeting is a venue for vigorous scientific discourse and discussion on topics in transport and turbulence in fusion plasmas. Its participation is international. The 2010 meeting was highly effective, with 139 registered participants and 131 presentations. This is remarkable for an even year (IAEA year) meeting. The meeting clearly fostered progress in understanding and control of turbulent transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗