Search NASA⌕ Search

SEARCH · Search NASA

Results for “testing and evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Evaluating the Feasibility of Using Strain Measured During Sinusoidal Rate Pumping Tests to Characterize an Aquifer

Pumping tests with sinusoidal variation in pumping rate have been proposed as a method for improving aquifer characterization. These tests can interrogate a larger aquifer volume than slug tests and they can be more sensitive to small variations in drawdown. Current methods of using sinusoidal variations of rate are based on measuring pressure signals from the reservoir or aquifer, which requires access to monitoring wells. An alternative approach has been developed that measures the strain in the vadose zone instead of pressure in the reservoir. An instrument has been developed at Clemson University that can measure small strains using optical fiber sensors, and we propose that it can be used to measure strain during sinusoidal pumping tests. The objective of this project is to evaluate the feasibility of measuring and interpreting the vertical strain in the vadose zone generated during a sinusoidal rate pumping tests to estimate aquifer and/or overburden properties. Pumping tests were performed at a site with a water table at 9 m and saturated saprolite from 9 to 30m depth. Sinusoidal pumping tests in the saprolite used different pumping amplitudes and periods while pressure was measured at three piezometers and vertical strain was measured in the vadose zone from 1 to 7 m depth. The delay time of the pressure increased linearly with distance, and it increased with the square root of the period, while the amplitude of the pressure decreased with distance and increased with amplitude. Vertical strain in the vadose zone varied with the same period as the pumping rate and the delay times were similar to those for pressures measured at similar radial distances. Delay times for the strain increased with an increasing propagation of the strain field. The hydraulic diffusivity was estimated using delay times for pressure and strain, and the results were compared with the values estimated from a constant-rate pumping test. The hydraulic diffusivity from the constant rate test was 0.039 m2/sec, whereas it was 0.053 (±0.05) m2/sec and 0.035 (±0.03) m2/sec from the pressure data and 0.08 (±0.022) m2/sec and 0.035 (±0.001) m2/sec from the strain data from sinusoidal tests of various periods and amplitudes. There is no statistical difference among these values. This study indicates that strain measurements in the vadose zone can be used to estimate aquifer properties during sinusoidal pumping tests.

Blais, Riley↗

Dynamic Mooring Field Experiment and Design of a Wave Energy Converter Platform Test System

Abstract This study evaluated a multi-catenary spread mooring system design of a mobile ocean test berth for wave energy converters (WECs), the Ocean Sentinel (OS) instrumentation buoy, through dynamic simulation, numerical analysis, and comparison with measured field motion data of the OS off the OR coast. First, the accuracy of the numerical employed model based on a fully-coupled method of the OS and its mooring lines was validated by comparing predicted mooring tensions to the field measurements. Then, the anchor movability, fatigue damage, and extreme mooring tension of the OS mooring system were analyzed to assess survivability. Field test results show that the numerical model provided accurate predictions of mooring tensions even under environmental conditions of strong wind, current, and waves. Factors affecting the accuracy are discussed. One mooring anchor was shown to have moved significantly during the ocean field test. Mooring fatigue damage was calculated for different levels of sea states. Design strengths of the mooring lines were calculated and analyzed.

Engineering↗

On the roles of welding residual stresses in determination of fracture toughness in austenitic stainless steel SUS 304 pipeline girth welds

Welding residual stresses especially the high tensile stresses are proved to have negative impacts on the fatigue and fracture behaviors of welded structures. In this study, a virtual fabrication of test specimens from welding process to specimen preparation was carried out by numerical simulation. An austenitic stainless steel multi-pass pipe welding was simulated by transient thermal–mechanical finite element analysis, the residual stresses were then mapped into the test specimen to evaluate fracture toughness. The findings in this study confirmed that, residual stress can be high in a sub-sized compact tensile specimen, which may accelerate or hinder the crack propagation during actual fatigue and fracture tests as reported in recent years. The influence of the cutting location and orientation of the specimen on fracture performance was investigated systematically to provide a fundamental understanding of welding residual stress and necessary insights into the specimen preparation procedure. Considering the limitation of measuring techniques and the complexity of the stress distribution, the developed numerical model can be a very useful tool to elucidate the stress evolution and quantify the effect of remaining welding stress on fracture toughness.

Fracture behavior↗

Irradiation of Advanced Cladding Specimens in the High Flux Isotope Reactor: Capsule Designs and Test Matrix

The Advanced Fuels Campaign (AFC) has initiated the Advanced Reactor Cladding (ARC) irradiation campaign to generate irradiation performance data for candidate fuel cladding concepts. The campaign includes a diverse set of ferritic/martensitic steels, oxide dispersion strengthened (ODS) alloys, FeCrAlbased alloys, coated materials, and welded cladding specimens produced through multiple US Department of Energy (DOE) programs and international collaborations. Three complementary experimental thrusts comprise the campaign: tensile testing (ARC Tensile) to rapidly screen candidate alloys, fracture toughness testing (ARC Fracture) to evaluate irradiation effects on crack resistance, and tubular weld testing (ARC Weld) to quantify irradiation-induced changes in the mechanical performance of end cap welds. This report documents the irradiation campaign design, including the selected materials, specimen types, irradiation matrix, and capsule designs for irradiation within the High Flux Isotope Reactor (HFIR). A total of 14 irradiation capsules were developed to achieve target irradiation temperatures between 300°C and 600°C and doses up to 30 dpa. Thermal analyses were performed using finite element methods to establish capsule geometries capable of achieving the desired specimen temperatures while accommodating differences in specimen geometry and material properties. The resulting capsule designs provide the basis for irradiation of the AFC-ARC experimental matrix and subsequent post-irradiation examination to assess the effects of neutron irradiation on advanced cladding materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental Analysis of Distribution Network Voltage Regulation Using Smart Inverters: Preprint

Smart inverters (SI) have huge potential in providing grid services which has not been fully realized yet. One of these grid services, distribution network voltage regulation by SI, can improve the network voltage by regulating the SI reactive and active power output. Voltage regulation by SI is much faster compared to traditional voltage regulating devices, e.g. tap changing transformer, capacitor banks. However, there is gap in available published literature on the characteristics of SIs when the SI is controlled by local controller or external control signal. This paper presents the experimental study to characterize SI reactive power regulation response to two different control methods: autonomous control method and remote dispatch method. It was found that IS reactive power regulation response could be significantly different in terms of delay, and ramp rate for these two methods. Finally, Power-Hardware-in-The-Loop (PHIL) tests were conducted to evaluate the performance of these two methods. The PHIL tests results show that SI response characteristics for autonomous control method and remote dispatch method need to be considered during planning for distribution network voltage regulation using SI.

autonomous control↗

Advancements in nuclear data evaluations in the unresolved resonance region [Slides]

Minimal updates to current capabilities (SAMMY/AMPX) and to the ENDF format are proposed to include threshold reaction for outgoing charged-particle channels in the URR formalism. If average resonance parameters are reported, probability tables for newly defined reactions channels may be needed, implemented, and tested. Nuclear data evaluation of n+ 35 Cl reactions can be considered the best case to apply the proposed updates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of Interior Cellular Shades in a Residential Building

Windows are major contributors to energy demand in residential homes because of their inferior thermal resistance compared with the opaque envelope and sometimes from unwanted solar heat gain. Window attachments can help to mitigate this demand by controlling the solar heat gains and enhancing the thermal resistance of the windows. In this study, the energy savings potential of cellular shades in residential homes is studied using experimental testing and energy simulations. The energy performance of the shading devices was experimentally tested during the heating season from December 2019 to May 2020 with a focus on cellular shades. Five shading devices—three single and two double cellular/cell-in-cell shades—were used to compare the performance with generic horizontal (venetian) blinds using two nearly identical sideby-side rooms in a residential building with their exterior window facing east. Another objective of the experimental testing was to evaluate any impact of the side-channel of the shading device on energy savings. To observe the impact of the side-channels on energy savings, from shades in two of the test cases, cellular shades with side-channels were used. From the experimental testing, daily energy savings in the range of 9% to 23% were observed by considering data from 6 p.m. until 6 a.m. of the next day.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Controlling distributed energy resources via deep reinforcement learning for load flexibility and energy efficiency

Behind-the-meter distributed energy resources (DERs), including building solar photovoltaic (PV) technology and electric battery storage, are increasingly being considered as solutions to support carbon reduction goals and increase grid reliability and resiliency. However, dynamic control of these resources in concert with traditional building loads, to effect efficiency and demand flexibility, is not yet commonplace in commercial control products. Traditional rule-based control algorithms do not offer integrated closed-loop control to optimize across systems, and most often, PV and battery systems are operated for energy arbitrage and demand charge management, and not for the provision of grid services. More advanced control approaches, such as MPC control have not been widely adopted in industry because they require significant expertise to develop and deploy. Recent advances in deep reinforcement learning (DRL) offer a promising option to optimize the operation of DER systems and building loads with reduced setup effort. However, there are limited studies that evaluate the efficacy of these methods to control multiple building subsystems simultaneously. Additionally, most of the research has been conducted in simulated environments as opposed to real buildings. This paper proposes a DRL approach that uses a deep deterministic policy gradient algorithm for integrated control of HVAC and electric battery storage systems in the presence of on-site PV generation. The DRL algorithm, trained on synthetic data, was deployed in a physical test building and evaluated against a baseline that uses the current best-in-class rule-based control strategies. Performance in delivering energy efficiency, load shift, and load shed was tested using price-based signals. The results showed that the DRL-based controller can produce cost savings of up to 39.6% as compared to the baseline controller, while maintaining similar thermal comfort in the building. The project team has also integrated the simulation components developed during this work as an OpenAIGym environment and made it publicly available so that prospective DRL researchers can leverage this environment to evaluate alternate DRL algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FTTN: Feature-Targeted Testing for Numerical Properties of NVIDIA & AMD Matrix Accelerators

FTTN is a test suite to evaluate the numerical behaviors of matrix accelerators of GPUs (NVIDIA Tensor Cores and AMD Matrix Cores) in a quick and simple setting. Matrix accelerators are heavily used in today's computationally intense applications to speed up matrix multiplications. This test suite provides a comprehensive study on the numerical behaviors of these accelerators, including support for subnormals, rounding modes, extra precision bits and FMA features. Is there

Laguna Peralta, Ignacio↗

Performance Evaluation of Multi-Vendor Grid-Forming Inverters for Grid-Connected Operation Through Hardware Experimentation: Preprint

Existing real-world projects of GFM inverters that operate in parallel to power grids typically are sized between dozens and a few hundreds Megawatt (MW) scale according to a recent NERC GFM inverter white paper. These large systems are often difficult to evaluate prior to deployments because of their large size. The performance of smaller GFM inverters (dozens to a few hundreds MW) that operate parallel with power grids (distribution systems) is even less understood. There is an opportunity to better understand these systems through hardware testing under controlled laboratory conditions. Therefore, this paper presents the functional performance evaluation tests of multiple (three) commercial GFM inverters when they operate in parallel with the grid through hardware experiments. The goal of these tests is to explore the GFM inverters' functionalities and dynamic response when in parallel with power grids to eventually develop universal specifications for GFM inverters. Both steady state (changing the inverter's frequency and voltage droop) and transient (adding step change in grid's frequency/voltage) tests are performed for each GFM inverter with the same testing circuit and testing protocol. The experimental results indicate the bench-marked performance that: 1) the GFM inverters can be dispatched through frequency and voltage droop intercepts to output the target power when paralleled to the grid; 2) the GFM inverters automatically respond to system frequency and voltage events to output the needed power, however, the GFM inverters all show stability issues when absorbing reactive power from the grid.

grid-forming inverters↗

Biotic degradation of acetonitrile. Limitations, controls and conversion rates

This document has been prepared to support Washington River Protection Solutions (WRPS) in their evaluation of technologies to remediate organic compounds in the Liquid Effluent Retention Facility (LERF)/Effluent Treatment Facility (ETF) during direct feed low activity waste (DFLAW) operations at Hanford. This report summarizes the results of a review of the available literature describing aerobic and anaerobic biological treatment of acetonitrile and proposes a test matrix to evaluate microbial degradation rates of acetonitrile. Numerous studies describe acetonitrile degradation by pure culture strains of bacteria, fungi, and yeast; however, the purpose of this review was to provide estimations of degradation under conditions that more closely approximate the Liquid Effluent Retention Facility (LERF) basins at the Hanford Site. To this end, documented limitations, controls, and conversion rates are summarized for mixed and natural microbial communities being maintained or operated as a biological treatment for wastewater processing. Based on the literature evaluation, the inherent capacity and rates of microbial degradation of acetonitrile are sufficiently high that if applied in the LERF basins, acetonitrile removal would be achieved. To be clear, though, published studies have not been conducted under conditions that approximate or that could be directly related to the LERF basins. Thus, a focused test matrix the encompasses LERF relevant conditions to specifically measure microbial degradation of acetonitrile is proposed and the results would provide the strong technical justification for use of this low-cost efficient biological process at LERF during DFLAW operations and beyond.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multiphysics analysis of fuel Fragmentation, Relocation, and dispersal Susceptibility–Part 2: High-Burnup Steady-State operating and fuel performance conditions

The US nuclear industry is pursuing increased cycle lengths and increasing the peak rod-averaged burnup in an effort to increase the economic viability of the US nuclear fleet. Increasing burnup will afford economic viability by enabling utilities to optimize core designs to reduce the number of fresh fuel assemblies per cycle and allow nuclear power plants to operate for a longer period of time. Longer operating periods will also decrease the number of outages experienced by a nuclear power plants and, therefore, offer utilities significant operational savings. However, extending the peak rod-averaged burnup beyond 62 GWd/tU results in operating fuel rods to higher burnup under higher power conditions. This operating regime is expected to result in higher fuel temperatures, fission gas release (FGR), and rod internal pressures (RIPs) that may challenge historical safety basis and affect high-burnup (HBU) experimental testing. In particular, these conditions directly affect fuel fragmentation, relocation, and dispersal (FFRD) susceptibility, so understanding the pretransient operating conditions is critical for developing test plans that evaluate the FFRD and develop strategies to mitigate it. This paper evaluates the operating conditions and fuel performance of HBU (greater than62 GWd/tU rod average) fuel. Additionally, it investigates fuel performance sensitivities and discusses the effect on fuel performance. Here, this work used two codes. Virtual Environment for Reactor Applications (VERA) was used to calculate steady-state power histories, identify HBU operating conditions using 10 different realistic HBU core designs, and down-select rods to a representative subset of fuel rods for subsequent BISON evaluation. The BISON fuel performance code was used to investigate steady-state HBU operating conditions and assess uncertainties associated with FGR and its effect on fuel temperatures and RIPs. The VERA and BISON results will provide direct input for HBU experimental testing and support subsequent TRACE and BISON transient fuel performance analyses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of China Experimental Fast Reactor Startup Tests (Final Report)

This report documents the results and observations on the Coordinated Research Project (CRP) of the International Atomic Energy Agency (IAEA) on “Neutronics Benchmark of CEFR Start-Up Tests.” The China Experimental Fast Reactor (CEFR) is a 65MWt sodium-cooled fast reactor with highly enriched uranium oxide fuels. The reactor achieved the first criticality in 2010, and series of start-up tests were conducted to measure various reactor physics parameters. In 2018, IAEA has launched the CRP for validation and qualification of member states' computation capabilities in the field of fast reactor simulation utilizing the measured data in the CEFR start-up test. Twenty-nine international organizations from eighteen member countries, including Argonne National Laboratory, have participated in the CRP.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Environmental Testing of SolarSCADA's SSI Data Acquisition System

In April of 2022, SolarSCADA, Inc., was awarded voucher funding to conduct research and analysis at the National Renewable Energy Laboratory (NREL) per the American-Made Solar Prize. SolarSCADA produces a fully integrated data acquisition system that is designed specifically for PV fields and includes a data monitoring platform. SolarSCADA is focused providing the SSI unit with all sensors/measurements per requirements in IEC-61724-1 [1] and with utility scale bankability. The objective of the SolarSCADA voucher funding was established as follows: Leverage NREL's existing calibration and environmental testing capabilities to evaluate the stability of the SSI channels and overall systeme in response to extreme environmental conditions associated with fielded PV.

14 SOLAR ENERGY↗

Test Results for Checking Reliability of Selected ENDF/B-VIII.0 Evaluated Uncertainties

This report summarizes error messages obtained from counter-checking whether 1 H, 9 Be, 12 C, 27 Al, 235,238 U and 238–242 Pu relative uncertainties of ENDF/B-VIII.0 are realistic. Large parts of this report were generated automatically by the code CovVal. This code allows to test the reliability of relative uncertainties of any isotope. It gives generic error and warning messages if evaluated relative uncertainties of a particular reaction are likely under- or over-estimated. In addition to these error and warning messages, I added comments whether the flagged uncertainties are truly under- or overestimated. I call out these uncertainties that should be further investigated and corrected by an evaluator for an upcoming release of ENDF/B-VIII.1.

07 ISOTOPE AND RADIATION SOURCES↗

Evaluation of desiccation cracking characteristics of inorganic micro-fiber-reinforced engineered barrier material (IMEBM) for geological repository

Abstract Buffer material is crucial for the engineering barrier system to dispose of high-level radioactive waste in a geological repository. A reliable buffer material should be able to maintain good sealing characteristics and minimize desiccation cracking. In this study, the effectiveness of inorganic fiber-reinforced engineering barrier material in reducing desiccation cracks in bentonite was evaluated via desiccation tests, image analysis, and air permeability tests. The effects of fiber type (E-glass fiber and basalt fiber) and fiber content (0.0%, 0.5%, 1.0%, 1.5%, 3.0%, and 5.0% of dry weight of the bentonite) on the development of desiccation cracks in the fiber–bentonite mixtures with the same given initial moisture content were evaluated. The results indicated that the addition of fibers could significantly reduce the crack size and area in bentonite during the drying. Basalt fibers showed a slightly better reinforcement effect than E-glass fibers when the fiber content was lower than 3.0%. The addition of fibers prevented the development of penetrating cracks and significantly reduced the permeability of the bentonite after drying. The permeabilities of basalt fiber- and E-glass fiber-reinforced bentonite composites with 3% reinforcement were 5.81 × 10 –11 m 2 and 7.24 × 10 –11 m 2 , respectively, which were 64 and 51 times smaller than that of pure bentonite. X-ray–CT observation of the internal structure of the samples after drying showed that the addition of fibers significantly changed the crack morphology and potentially increased the tortuosity.

Feng, Yuan↗

Analysis of Dust and Corrosion Witness Samples Recovered from SNF Dry Storage Systems, Maine Yankee, 2023

This report documents the results of a long-term (5.79 year) exposure of 4-point bend corrosion test samples in the inlet and outlet vents of four spent nuclear fuel dry storage systems at the Maine Yankee Independent Spent Fuel Storage Installation. The goal of the test was to evaluate the corrosiveness of salt aerosols in a realistic near-marine environment, providing a data set for improved understanding of stress corrosion cracking of spent nuclear fuel dry storage canisters. Examination of the samples after extraction showed minor corrosion was present, mostly on rough-ground surfaces. However, dye penetrant testing showed that no SCC cracks were present. Dust collected on coupons co-located with the corrosion specimens was analyzed by scanning electron microscopy and leached to determine the soluble salts present. The dust was mostly organic material (pollen and stellate trichomes), with lesser detrital mineral grains. Salts present were a mix of sea-salts and continental salts, with chloride dominating the anions, but significant amounts of nitrate were also present. Both corrosion samples and dust samples showed evidence of wetting, indicating entry of water into the vents. The results of this field test suggest that the environment at Maine Yankee is not highly aggressive, although extrapolation from the periodically wetted vent samples to the hot, dry, canister surface may be difficult. No stress corrosion cracks were observed, but minor corrosion was present despite high nitrate concentrations in the salts. These observations may help address the ongoing question of the importance of nitrate in suppressing corrosion and SCC.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗