Search NASA⌕ Search

SEARCH · Search NASA

Results for “time shift”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Interpreting short gamma-ray burst progenitor kicks and time delays using the host galaxy-dark matter halo connection

Nearly 20% of short gamma-ray bursts (sGRBs) have no observed host galaxies. Combining this finding with constraints on galaxies' dark matter halo potential wells gives strong limits on the natal kick velocity distribution for sGRB progenitors. For the best-fitting velocity distribution, one in five sGRB progenitors receives a natal kick above 150 km s{sup –1}, consistent with merging neutron star models but not with merging white dwarf binary models. This progenitor model constraint is robust to a wide variety of systematic uncertainties, including the sGRB progenitor time-delay model, the Swift redshift sensitivity, and the shape of the natal kick velocity distribution. We also use constraints on the galaxy-halo connection to determine the host halo and host galaxy demographics for sGRBs, which match extremely well with available data. Most sGRBs are expected to occur in halos near 10{sup 12} M {sub ☉} and in galaxies near 5 × 10{sup 10} M {sub ☉} (L {sub *}); unobserved faint and high-redshift host galaxies contribute a small minority of the observed hostless sGRB fraction. We find that sGRB redshift distributions and host galaxy stellar masses weakly constrain the progenitor time-delay model; the active versus passive fraction of sGRB host galaxies may offer a stronger constraint. Finally, we discuss how searches for gravitational wave optical counterparts in the local universe can reduce follow-up times using these findings.

79 ASTRONOMY AND ASTROPHYSICS↗

Topological Electronic Structure Evolution with Symmetry Breaking Spin Reorientation in (Fe 1–x Co x )Sn

Topological materials hosting kagome lattices have drawn considerable attention due to the interplay between topology, magnetism, and electronic correlations. The (Fe 1–x Co x )Sn system not only hosts a kagome lattice but has a tunable symmetry-breaking magnetic moment with temperature and doping. In this study, angle-resolved photoemission spectroscopy and first-principles calculations are used to investigate the interplay between the topological electronic structure and varying magnetic moment from the planar to axial antiferromagnetic phases. Here, evidence for a theoretically predicted gap at the Dirac point is revealed in the low-temperature axial phase, but no gap opening is observed across a temperature-dependent magnetic phase transition. However, topological surface bands are observed to shift in energy as the surface magnetic moment is reduced or becomes disordered over time during experimental measurements. The shifting surface bands may preclude the determination of a temperature-dependent bulk gap, but this highlights the intricate connections between magnetism and topology with a surface/bulk dichotomy that can affect material properties and their interrogation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Vision 20/20: Increased image resolution versus reduced radiation exposure

This is a review of methods, currently and potentially, available for significantly reducing x-ray exposure in medical x-ray imaging. It is stimulated by the radiation exposure implications of the growing use of helical scanning, multislice, x-ray computed tomography for screening, such as for coronary artery atherosclerosis and cancer of the colon and lungs. Screening requires high-throughput imaging with high spatial and contrast resolution to meet the need for high sensitivity and specificity of detection and classification of specific imaged features. To achieve this goal beyond what is currently available with x-ray imaging methods requires increased x-ray exposure, which increases the risk of tissue damage and ultimately cancer development. These consequences limit the utility of current x-ray imaging in screening of at-risk subjects who have not yet developed the clinical symptoms of disease. Current methods for reducing x-ray exposure in x-ray imaging, mostly achieved by increasing sensitivity and specificity of the x-ray detection process, may still have potential for an up-to-tenfold decrease. This could be sufficient for doubling the spatial resolution of x-ray CT while maintaining the current x-ray exposure levels. However, a spatial resolution four times what is currently available might be needed to adequately meet the needs for screening. Consequently, for the proposed need to increase spatial resolution, an additional order of magnitude of reduction of x-ray exposure would be needed just to keep the radiation exposure at current levels. This is conceivably achievable if refraction, rather than the currently used attenuation, of x rays is used to generate the images. Existing methods that have potential for imaging the consequences of refracted x ray in a clinical setting are (1) by imaging the edge enhancement that occurs at the interfaces between adjacent tissues of different refractive indices, or (2) by imaging the changes in interference patterns resulting from moving grids which alter the refraction of x rays, that have passed through the body, in a predictable fashion, and (3) theoretically, by an image generated from the change in time-of-flight of x-ray photons passing through the body. Imaging phase shift or change in time-of-flight, rather than attenuation, of x-ray photons through tissues presents formidable technological problems for whole-body 3D imaging. However, if achievable in a routine clinical setting, these approaches have the potential for greatly expanding the use of x-ray imaging for screening. This overview examines the increased contrast resolution and reduced radiation exposure that might be achievable by the above-mentioned methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Meeting Residential Ventilation Standards Through Dynamic Control of Ventilation Systems

Existing ventilation standards, including American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE) Standard 62.2, specify continuous operation of a defined mechanical ventilation system to provide minimum ventilation, with time-based intermittent operation as an option. This requirement ignores several factors and concerns including: other equipment such as household exhaust fans that might incidentally provide ventilation, negative impacts of ventilation when outdoor pollutant levels are high, the importance of minimizing energy use particularly during times of peak electricity demand, and how the energy used to condition air as part of ventilation system operation changes with outdoor conditions. Dynamic control of ventilation systems can provide ventilation equivalent to or better than what is required by standards while minimizing energy costs and can also add value by shifting load during peak times and reducing intake of outdoor air contaminants. This article describes the logic that enables dynamic control of whole-house ventilation systems to meet the intent of ventilation standards and demonstrates the dynamic ventilation system control concept through simulations and field tests of the Residential Integrated Ventilation-Energy Controller (RIVEC).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Small-scale clumping at recombination and the Hubble tension

Despite the success of the standard ΛCDM model of cosmology, recent data improvements have made tensions emerge between low- and high-redshift observables, most importantly in determinations of the Hubble constant H 0 and the (rescaled) clustering amplitude S 8 . The high-redshift data, from the cosmic microwave background (CMB), crucially relies on recombination physics for its interpretation. In this work, we study how small-scale baryon inhomogeneities (i.e., clumping) can affect recombination and consider whether they can relieve both the H 0 and S 8 tensions. Such small-scale clumping, which may be caused by primordial magnetic fields or baryon isocurvature below kpc scales, enhances the recombination rate even when averaged over larger scales, shifting recombination to earlier times. We introduce a flexible clumping model, parametrized via three spatial zones with free densities and volume fractions, and use it to study the impact of clumping on CMB observables. We find that increasing H 0 decreases both Ω m and S 8 , which alleviates the S 8 tension. On the other hand, the shift in Ω m is disfavored by the low-z baryon-acoustic-oscillations measurements. We find that the clumping parameters that can change the CMB sound horizon enough to explain the H 0 tension also alter the damping tail, so they are disfavored by current Planck 2018 data. We test how the CMB damping-tail information rules out changes to recombination by first removing ℓ > 1000 multipoles in Planck data, where we find that clumping could resolve the H 0 tension. Furthermore, we make predictions for future CMB experiments, as their improved damping-tail precision can better constrain departures from standard recombination. Both the Simons Observatory and CMB-S4 will provide decisive evidence for or against clumping as a resolution to the H 0 tension.

79 ASTRONOMY AND ASTROPHYSICS↗

Gain Shift Corrections at Chi-Nu

Ambient conditions have the potential to cause changes in liquid scintillator detector gain that vary with time and temperature. These gain shifts can lead to poor resolution in both energy as well as pulse shape discrimination. In order to correct for these shifts in the Chi-Nu high energy array, a laser system has been developed for calibration of the pulse height signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temporal Response of Nonequilibrium Correlated Electrons

In this work we examine the time-resolved, instantaneous current response for the spinless Falicov-Kimball model at half-filling, on both sides of the Mott-Hubbard metal-insulator transition, driven by a strong electric field pump pulse. The results are obtained using an exact, nonequilibrium, many-body impurity solution specifically designed to treat the out-of-equilibrium evolution of electrons in time-dependent fields. We provide a brief introduction to the method and its computational details. We find that the current develops Bloch oscillations, similar to the case of DC driving fields, with an additional amplitude modulation, characterized by beats and induced by correlation effects. Correlations primarily manifest themselves through an overall reduction in magnitude and shift in the onset time of the current response with increasing interaction strength.

COMP, MATSCI, OTHER↗

Methods for diagnosing and quantifying double pulsing in a Uranium Neutron Collar system using shift register logic

Double pulsing in neutron coincidence counters is the result of a pulse processing chain-3He proportional counter timing incompatibility known to nondestructive assay system designers. It is not currently widely acknowledged, or accounted for, in the user community. However, it is gaining attention as list mode data acquisition and analysis becomes more commonly used for system diagnostics, revealing features that have been overlooked by historic timing gate selection using traditional shift register data acquisition methods. Double pulsing increases the apparent number of measured neutron events from a source. Therefore, it may contribute to a falsely increased count rate if present at the operational high voltage used when assaying samples, even with set predelays. The authors have previously studied the effects of double pulsing, using list mode data acquisition and analysis on neutron pulse trains in three common neutron coincidence counting systems used in routine measurements for international safeguards: a Canberra Industries JCC-71 Neutron Coincidence Collar, a variant on the Canberra Industries JCC-51 Active Well Neutron Coincidence Counter (the Large Volume Active Well Neutron Coincidence Counter), and an AnTech Inc. N2071 Neutron Coincidence Collar. We find that this non-ideal behavior was isolated to the Amptek A111 Charge Sensitive Preamplifier & Discriminator chip used in both the Canberra Industries and Antech systems. The double pulsing fraction was calculated in post-analysis for various high voltage settings in these A111-based systems, assuming no predelay settings. In this work, the authors expand upon this identification and analysis to make it more translatable between list mode data acquisition and analysis and shift register-based analysis. By investigating the double pulsing fractions in a JCC-71 Uranium Neutron Collar as a function of predelay settings, as well as describing and performing alternative tests and analyses to diagnose and quantify the double pulsing using shift register logic, this work hopes to complete the picture of double pulsing identification and analysis.

Safeguards↗

Vector Analysis of Prostate Patient Setup With Image-Guided Radiation Therapy via kV Cone Beam Computed Tomography

Purpose: To analyze the daily setup variations in a cohort of intensity-modulated radiation therapy (IMRT) prostate cancer patients who had received daily image-guided RT without the use of fiducial markers to determine if daily image guidance is necessary. Methods and Materials: 2134 Kilovoltage (kV) cone beam computed tomography (CBCT) images were analyzed, with three shifts recorded for each image. The number of times that the vector of the combined shifts would have exceeded the planning tumor volume (PTV) margin was tallied. Then, the average scalar shift of the first five images was removed from all subsequent images for a given patient, and the number of days for which the shift vector was greater than the three-dimensional clinical tumor volume-PTV (3D CTV-PTV) margin (8 mm, created with rolling ball technique) was recorded. Additionally, the scalar shifts from every other fraction were studied to determine if the individual patient's shift vector would be adequately sampled if CBCT was not performed daily, thus reducing patient imaging dose without compromising treatment quality. Results: There were 297 cases where the vector shift was initially greater than the PTV margin. By correcting each patient's data set by the average shift of their first five images the total was 248 cases. By considering only every other image of each patient data set (after correction for the first 5 days), only 137 days in which the CTV was outside the PTV would have been seen. Conclusions: Daily imaging is recommended for prostate cancer IMRT patients in order to know the 3D (vector) position of the CTV and to ensure that it is always within the PTV margin. Correcting the data set by the average shift from the first 5 days reduces the overall number of outlier days but does not eliminate them completely.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-Time Observation of Molecular Spinning with Angular High-Harmonic Spectroscopy

We demonstrate an angular high-harmonic spectroscopy method to probe the spinning dynamics of a molecular rotation wave packet in real time. With the excitation of two time-delayed, polarization-skewed pump pulses, the molecular ensemble is impulsively kicked to rotate unidirectionally, which is subsequently irradiated by another delayed probe pulse for high-order harmonic generation (HHG). The spatiotemporal evolution of the molecular rotation wave packet is visualized from the time-dependent angular distributions of the HHG yields and frequency shift measured at various polarization directions and time delays of the probe pulse. Here, the observed frequency shift in HHG is demonstrated to arise from the nonadiabatic effect induced by molecular spinning. Different from the previous spectroscopic and Coulomb explosion imaging techniques, the angular high-harmonic spectroscopy method can reveal additionally the electronic structure and multiple orbitals of the sampled molecule. All the experimental findings are well reproduced by numerical simulations. Further extension of this method would provide a powerful tool for probing complex polyatomic molecules with HHG spectroscopy.

74 ATOMIC AND MOLECULAR PHYSICS↗

An OVERVIEW of MICROPHONICS in CEBAF and CURRENT MODERATION TECHNIQUES

Superconducting RF (SRF) structures are susceptible to frequency detuning from external vibrations and modal mechanical resonances in the structure. These small disturbances, known as microphonics, require additional RF power in CW accelerating structures since the frequency is constantly shifting. In the Jefferson Lab CEBAF accelerator, time and frequency data of this frequency shift have been recorded for many years, allowing a retrospective analysis of different microphonics-mitigation techniques. Some of these techniques are specific to the design of each CEBAF cryomodule, for example implementing BNNT damping material on the cavity string. Other techniques are universal such as affixing vacuum lines and reinforcing waveguide structures.

Powers, Tom↗

Lifetime predictions for dimmable two-channel drivers for color tuning luminaires

Two-channel tunable white lighting (TWL) systems represent the next wave of solid-state lighting (SSL) systems and promise flexibility in light environment while maintaining the high reliability and luminous efficacy expected with SSL devices. TWL systems utilize LED assemblies consisting of two different LED spectra (i.e., often a warm white assembly and a cool white assembly) that are integrated into modules. While these systems provide the ability to adjust the lighting spectrum to match the physiology needs of the task at hand, they also are a potentially more complex lighting system from a performance and reliability perspective. We report an initial study on the reliability performance of such lighting systems including an examination of the lumen maintenance and chromaticity stability of warm white and cool white LED assemblies and the multi-channel driver that provides power to the assemblies. Accelerated stress tests including operational bake tests conducted at 75°C and 95°C were used to age the LED modules, while more aggressive temperature and humidity tests were used for the drivers in this study. Small differences in the performance between the two LED assemblies were found and can be attributed to the different phosphor chemistries. The lumen maintenances of both LED assemblies were excellent. The warm white LED assemblies were found to shift slightly in the green color direction over time while the cool white LED assemblies shifted slightly in the yellow color direction. The net result of these chromaticity shifts is a small, barely perceptible reduction in the tuning range after 6,000 hours of exposure to an accelerating elevated temperature of 75°C.

Chromaticity↗

A real-time dynamic-MLC control algorithm for delivering IMRT to targets undergoing 2D rigid motion in the beam's eye view

An MLC control algorithm for delivering intensity modulated radiation therapy (IMRT) to targets that are undergoing two-dimensional (2D) rigid motion in the beam's eye view (BEV) is presented. The goal of this method is to deliver 3D-derived fluence maps over a moving patient anatomy. Target motion measured prior to delivery is first used to design a set of planned dynamic-MLC (DMLC) sliding-window leaf trajectories. During actual delivery, the algorithm relies on real-time feedback to compensate for target motion that does not agree with the motion measured during planning. The methodology is based on an existing one-dimensional (1D) algorithm that uses on-the-fly intensity calculations to appropriately adjust the DMLC leaf trajectories in real-time during exposure delivery [McMahon et al., Med. Phys. 34, 3211-3223 (2007)]. To extend the 1D algorithm's application to 2D target motion, a real-time leaf-pair shifting mechanism has been developed. Target motion that is orthogonal to leaf travel is tracked by appropriately shifting the positions of all MLC leaves. The performance of the tracking algorithm was tested for a single beam of a fractionated IMRT treatment, using a clinically derived intensity profile and a 2D target trajectory based on measured patient data. Comparisons were made between 2D tracking, 1D tracking, and no tracking. The impact of the tracking lag time and the frequency of real-time imaging were investigated. A study of the dependence of the algorithm's performance on the level of agreement between the motion measured during planning and delivery was also included. Results demonstrated that tracking both components of the 2D motion (i.e., parallel and orthogonal to leaf travel) results in delivered fluence profiles that are superior to those that track the component of motion that is parallel to leaf travel alone. Tracking lag time effects may lead to relatively large intensity delivery errors compared to the other sources of error investigated. However, the algorithm presented is robust in the sense that it does not rely on a high level of agreement between the target motion measured during treatment planning and delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Axial resonances a$_{1}$(1260), b$_{1}$(1235) and their decays from the lattice

The light axial-vector resonances $a_1(1260)$ and $b_1(1235)$ are explored in Nf=2 lattice QCD by simulating the corresponding scattering channels $\rho\pi$ and $\omega\pi$. Interpolating fields $\bar{q} q$ and $\rho\pi$ or $\omega\pi$ are used to extract the s-wave phase shifts for the first time. The $\rho$ and $\omega$ are treated as stable and we argue that this is justified in the considered energy range and for our parameters $m_\pi\simeq 266~$MeV and $L\simeq 2~$fm. We neglect other channels that would be open when using physical masses in continuum. Assuming a resonance interpretation a Breit-Wigner fit to the phase shift gives the $a_1(1260)$ resonance mass $m_{a1}^{res}=1.435(53)(^{+0}_{-109})$ GeV compared to $m_{a1}^{exp}=1.230(40)$ GeV. The $a_1$ width $\Gamma_{a1}(s)=g^2 p/s$ is parametrized in terms of the coupling and we obtain $g_{a_1\rho\pi}=1.71(39)$ GeV compared to $g_{a_1\rho\pi}^{exp}=1.35(30)$ GeV derived from $\Gamma_{a1}^{exp}=425(175)$ MeV. In the $b_1$ channel, we find energy levels related to $\pi(0)\omega(0)$ and $b_1(1235)$, and the lowest level is found at $E_1 \gtrsim m_\omega+m_\pi$ but is within uncertainty also compatible with an attractive interaction. Lastly, assuming the coupling $g_{b_1\omega\pi}$ extracted from the experimental width we estimate $m_{b_1}^{res}=1.414(36)(^{+0}_{-83})$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Global optimization of data quality checks on 2-D and 3-D networks of GPR cross-well tomographic data for automatic correction of unknown well deviations

Significant errors related to poor time zero estimation, well deviation or mislocation of the transmitter (TX) and receiver (RX) stations can render even the most sophisticated modeling and inversion routine useless. Previous examples of methods for the analysis and correction of data errors in geophysical tomography include the works of Maurer and Green (1997), Squires et al. (1992) and Peterson (2001). Here we follow the analysis and techniques of Peterson (2001) for data quality control and error correction. Through our data acquisition and quality control procedures we have very accurate control on the surface locations of wells, the travel distance of both the transmitter and receiver within the boreholes, and the change in apparent zero time. However, we often have poor control on well deviations, either because of economic constraints or the nature of the borehole itself prevented the acquisition of well deviation logs. Also, well deviation logs can sometimes have significant errors. Problems with borehole deviations can be diagnosed prior to inversion of travel-time tomography data sets by plotting the apparent velocity of a straight ray connecting a transmitter (TX) to a receiver (RX) against the take-off angle of the ray. Issues with the time-zero pick or distances between wells appear as symmetric smiles or frown in these QC plots. Well deviation or dipping-strong anisotropy will result in an asymmetric correlation between apparent velocity and take-off angle (Figure 1-B). In addition, when a network of interconnected GPR tomography data is available, one has the additional quality constraint of insuring that there is continuity in velocity between immediately adjacent tomograms. A sudden shift in the mean velocity indicates that either position deviations are present or there is a shift in the pick times. Small errors in well geometry may be effectively treated during inversion by including weighting, or relaxation, parameters into the inversion (e.g. Bautu et al., 2006). In the technique of algebraic reconstruction tomography (ART), which is used herein for the travel time inversion (Peterson et al., 1985), a small relaxation parameter will smooth imaging artifacts caused by data errors at the expense of resolution and contrast (Figure 2). However, large data errors such as unaccounted well deviations cannot be adequately suppressed through inversion weighting schemes. Previously, problems with tomograms were treated manually. However, in large data sets and/or networks of data sets, trial and error changes to well geometries become increasingly difficult and ineffective. Mislocation of the transmitter and receiver stations of GPR cross-well tomography data sets can lead to serious imaging artifacts if not accounted for prior to inversion. Previously, problems with tomograms have been treated manually prior to inversion. In large data sets and/or networks of tomographic data sets, trial and error changes to well geometries become increasingly difficult and ineffective. Our approach is to use cross-well data quality checks and a simplified model of borehole deviation with particle swarm optimization (PSO) to automatically correct for source and receiver locations prior to tomographic inversion. We present a simple model of well deviation, which is designed to minimize potential corruption of actual data trends. We also provide quantitative quality control measures based on minimizing correlations between take-off angle and apparent velocity, and a quality check on the continuity of velocity between adjacent wells. This methodology is shown to be accurate and robust for simple 2-D synthetic test cases. Plus, we demonstrate the method on actual field data where it is compared to deviation logs. This study shows the promise for automatic correction of well deviations in GPR tomographic data. Analysis of synthetic data shows that very precise estimates of well deviation can be made for small deviations, even in the presence of static data errors. However, the analysis of the synthetic data and the application of the method to a large network of field data show that the technique is sensitive to data errors varying between neighboring tomograms.

54 ENVIRONMENTAL SCIENCES↗

THE TYPE II SUPERNOVA RATE IN z {approx} 0.1 GALAXY CLUSTERS FROM THE MULTI-EPOCH NEARBY CLUSTER SURVEY

We present seven spectroscopically confirmed Type II cluster supernovae (SNe II) discovered in the Multi-Epoch Nearby Cluster Survey, a supernova survey targeting 57 low-redshift 0.05 < z < 0.15 galaxy clusters with the Canada-France-Hawaii Telescope. We find the rate of Type II supernovae within R{sub 200} of z {approx} 0.1 galaxy clusters to be 0.026{sup +0.085}{sub -0.018}(stat){sup +0.003}{sub -0.001}(sys) SNuM. Surprisingly, one SN II is in a red-sequence host galaxy that shows no clear evidence of recent star formation (SF). This is unambiguous evidence in support of ongoing, low-level SF in at least some cluster elliptical galaxies, and illustrates that galaxies that appear to be quiescent cannot be assumed to host only Type Ia SNe. Based on this single SN II we make the first measurement of the SN II rate in red-sequence galaxies, and find it to be 0.007{sup +0.014}{sub -0.007}(stat){sup +0.009}{sub -0.001}(sys) SNuM. We also make the first derivation of cluster specific star formation rates (sSFR) from cluster SN II rates. We find that for all galaxy types the sSFR is 5.1{sup +15.8}{sub -3.1}(stat) {+-} 0.9(sys) M{sub Sun} yr{sup -1} (10{sup 12} M{sub Sun }){sup -1}, and for red-sequence galaxies only it is 2.0{sup +4.2}{sub -0.9}(stat) {+-} 0.4(sys) M{sub Sun} yr{sup -1} (10{sup 12} M{sub Sun }){sup -1}. These values agree with SFRs measured from infrared and ultraviolet photometry, and H{alpha} emission from optical spectroscopy. Additionally, we use the SFR derived from our SNII rate to show that although a small fraction of cluster Type Ia SNe may originate in the young stellar population and experience a short delay time, these results do not preclude the use of cluster SN Ia rates to derive the late-time delay time distribution for SNe Ia.

79 ASTRONOMY AND ASTROPHYSICS↗

Arsenic induces structural and compositional colonic microbiome change and promotes host nitrogen and amino acid metabolism

Chronic exposure to arsenic in drinking water causes cancer and non-cancer diseases. However, mechanisms for chronic arsenic-induced pathogenesis, especially in response to lower exposure levels, are unclear. In addition, the importance of health impacts from xeniobiotic-promoted microbiome changes is just being realized and effects of arsenic on the microbiome with relation to disease promotion are unknown. To investigate impact of arsenic exposure on both microbiome and host metabolism, the stucture and composition of colonic microbiota, their metabolic phenotype, and host tissue and plasma metabolite levels were compared in mice exposed for 2, 5, or 10 weeks to 0, 10 (low) or 250 (high) ppb arsenite (As(III)). Genotyping of colonic bacteria revealed time and arsenic concentration dependent shifts in community composition, particularly the Bacteroidetes and Firmicutes, relative to those seen in the time-matched controls. Arsenic-induced erosion of bacterial biofilms adjacent to the mucosal lining and changes in the diversity and abundance of morphologically distinct species indicated changes in microbial community structure. Bacterical spores increased in abundance and intracellular inclusions decreased with high dose arsenic. Interestingly, expression of arsenate reductase (arsA) and the As(III) exporter arsB, remained unchanged, while the dissimilatory nitrite reductase (nrfA) gene expression increased. In keeping with the change in nitrogen metabolism, colonic and liver nitrite and nitrate levels and ratios changed with time. In addition, there was a concomitant increase in pathogenic arginine metabolites in the mouse circulation. These data suggest that arsenic exposure impacts the microbiome and microbiome/host nitrogen metabolism to support disease enhancing pathogenic phenotypes. - Highlights: • Arsenic exposure induces changes in host and host nitrogen metabolism that cause progresive change in the microbiome. • A polyphasic approach reveals changes in microbial community structure, composition and nitrite reductase expression. • The profile of nitrogen and nitroamino acid change caused by arsenic may relect increased risk of cardiovascular pathogenesis.

60 APPLIED LIFE SCIENCES↗

HE 1113-0641: THE SMALLEST-SEPARATION QUADRUPLE LENS IDENTIFIED BY A GROUND-BASED OPTICAL TELESCOPE

The Hamburg/ESO quasar HE 1113-0641 is found to be a quadruple gravitational lens, based on observations with the twin 6.5 m Magellan telescopes at the Las Campanas Observatory, and subsequently with the Hubble Space Telescope. The z{sub S} = 1.235 quasar appears in a cross configuration, with i' band magnitudes ranging from 18.0 to 18.8. With a maximum image separation of 0''.67, this is the smallest-separation quadruple ever identified using a ground-based optical telescope. Point-spread function (PSF) subtraction reveals a faint lensing galaxy. A simple lens model succeeds in predicting the observed positions of the components, but fails to match their observed flux ratios by up to a magnitude. We estimate the redshift of the lensing galaxy to be z{sub L} {approx} 0.7. Time delay estimates are on the order of a day, suggesting that the flux ratio anomalies are not due to variability of the quasar, but may result from substructure or microlensing in the lens galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗