Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage regulators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Exemption of lattice collapse in Ni–MnO 2 birnessite regulated by the structural water mobility

Lattice collapse and associated mechanical fracture frequently occur in Li-intercalated metal oxide cathodes at the deep charge state upon Li-ion removal, governed by chemical compositions and the resulting electron density of the oxygen atoms. However, similar lattice collapse for metal oxide electrodes in aqueous storage and its mitigation have not been well studied. In this work, we reported the lattice collapse of MnO 2 layered birnessite during the aqueous de-sodiation process at high voltage due to the structural water motion, as evidenced by in situ XRD. Unlike non-aqueous Li-intercalated electrodes, Ni-dopants mitigated the lattice collapse of birnessite at deep charge states. Moreover, density functional theory (DFT) calculations showed that Ni doping induces charge depletion of lattice oxygen due to its higher electronegativity than Mn. This charge reduction, in turn, yields a significant decrease in electrostatic repulsion between the oxygens belonging to lattice and structural water. Classical molecular dynamics simulations based on atomic charges obtained from DFT elucidate that Ni-doping facilitates immobilization of structural water in (Ni)MnO 2 and prevents lattice collapse upon Na-ion removal. (Ni)MnO 2 exempted from lattice collapse shows an improved storage capacity relative to MnO 2 while maintaining similar cycling stability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Self-regulating power management for a neural network system

A neural network runs a known input data set using an error free power setting and using an error prone power setting. The differences in the outputs of the neural network using the two different power settings determine a high level error rate associated with the output of the neural network using the error prone power setting. If the high level error rate is excessive, the error prone power setting is adjusted to reduce errors by changing voltage and/or clock frequency utilized by the neural network system. If the high level error rate is within bounds, the error prone power setting can remain allowing the neural network to operate with an acceptable error tolerance and improved efficiency. The error tolerance can be specified by the neural network application.

Kegel, Andrew G.↗

Self-regulating power management for a neural network system

A neural network runs a known input data set using an error free power setting and using an error prone power setting. The differences in the outputs of the neural network using the two different power settings determine a high level error rate associated with the output of the neural network using the error prone power setting. If the high level error rate is excessive, the error prone power setting is adjusted to reduce errors by changing voltage and/or clock frequency utilized by the neural network system. If the high level error rate is within bounds, the error prone power setting can remain allowing the neural network to operate with an acceptable error tolerance and improved efficiency. The error tolerance can be specified by the neural network application.

Kegel, Andrew G.↗

An Optimal Power Control Strategy for Grid-Following Inverters in a Synchronous Frame

This work proposes a power control strategy based on the linear quadratic regulator with optimal reference tracking (LQR-ORT) for a three-phase inverter-based generator (IBG) using an LCL filter. The use of an LQR-ORT controller increases robustness margins and reduces the quadratic value of the power error and control inputs during transient response. A model in a synchronous reference frame that integrates power sharing and voltage–current (V–I) dynamics is also proposed. This model allows for analyzing closed-loop eigenvalue location and robustness margins. The proposed controller was compared against a classical droop approach using proportional-resonant controllers for the inner loops. Mathematical analysis and hardware-in-the-loop (HIL) experiments under variations in the LCL filter components demonstrate fulfillment of robustness and performance bounds of the LQR-ORT controller. Experimental results demonstrate accuracy of the proposed model and the effectiveness of the LQR-ORT controller in improving transient response, robustness, and power decoupling.

24 POWER TRANSMISSION AND DISTRIBUTION↗

How Does Water Dissociation Work in Bipolar Membranes?

Bipolar membranes (BPMs) create counteracting spatial gradients of pH and electrostatic potential in electrochemical systems, enabling applications in pH regulation, electrocatalysis, and separations. At the polarized junction of a BPM the water dissociation (WD, 2H2O ⇌ H3O+ + OH-) reaction can be driven, but it remains poorly understood. In this Perspective, we integrate molecular insights from bulk-water autoionization and the associated field effects with continuum descriptions of BPM electrostatics and experimental WD kinetic analyses to describe possible mechanisms of voltage-driven WD. Pristine BPM junctions highlight both the limits of primarily electric-field-driven WD and the practical challenges of junction stability at extreme reverse bias. Introducing heterogeneous catalyst layers, commonly metal oxides and graphene oxides, accelerates WD by orders of magnitude through hypothesized coupled effects in which surface acid-base functionality and high-density hydroxyl sites mediate proton-transfer steps, and catalyst mobile electronic/ionic charges redistribute the junction electric potential drop to shape the local electric fields and reactive microenvironments. Kinetic analyses suggest two regimes of heterogeneous WD mechanism, including field-driven ordering of interfacial water and a Second-Wien-Effect dissociation-barrier lowering. We conclude by defining the key unknown variables (local pH, electrostatic potential, catalyst charge state and relationships among mechanisms) and outlining experimental and multiscale modeling strategies needed for predictive WD catalysis and for controlling related ion-transfer reactions.

Wu, Yifan↗

A Stable and Ultrafast Control for Multiparallel Grid-Tied SiC Inverters With LVRT Capability Considering Cable Impedance

The stability of multiparalleled grid-tied inverters remains a challenging issue especially during low-voltage ride-through (LVRT) in the presence of grid impedance. SiC device-based grid-tied inverters can achieve advantages such as higher efficiency, reduced size of interface filters, and fast dynamics; however, they can exacerbate this stability issue particularly when LVRT occurs along with high inrush current due to their low inertia characteristics. In this article, a direct deadbeat control method without any PI control loop is proposed for multiparallel grid-tied SiC inverters. The proposed control achieves instantaneous current regulations within switching cycles. In addition, it mitigates high inrush currents and maintains stability during LVRT transients without requiring mode transitions between normal and LVRT operation modes, thereby achieving an ultrafast response and seamless operation through this unified control method. The Lyapunov method is applied to analyze the multiparallel inverter stability in the presence of grid impedance with proposed deadbeat control method. The inverter V-I trajectories during LVRT transients are derived to illustrate the ultrafast and stable feature of proposed control. Finally, the experimental results of two grid-tied SiC inverters operating at LVRT transients are provided to verify the advantages of the proposed control method.

14 SOLAR ENERGY↗

Grid Integration of Offshore Wind Power: Standards, Control, Power Quality and Transmission

Offshore wind is expected to be a major player in the global efforts toward decarbonization, leading to exceptional changes in modern power systems. Understanding the impacts and capabilities of the relatively new and uniquely positioned assets in grids with high integration levels of inverter-based resources, however, is lacking, raising concerns about grid reliability, stability, power quality, and resilience, with the absence of updated grid codes to guide the massive deployment of offshore wind. To help fill the gap, this paper presents an overview of the state-of-the-art technologies of offshore wind power grid integration. First, the paper investigates the most current grid requirements for wind power plant integration, based on a harmonized European Network of Transmission System Operators (ENTSO-E) framework and notable international standards, and it illuminates future directions. The paper discusses the wind turbine and wind power plant control strategies, and new control approaches, such as grid-forming control, are presented in detail. The paper reviews recent research on the ancillary services that offshore wind power plants can potentially provide, which, when harmonized, will not only comply with regulations but also improve the value of the asset. The paper explores topics of wind power plant harmonics, reviewing the latest standards in detail and outlining mitigation methods. The paper also presents stability analysis methods for wind power plants, with discussions centered on validity and computational efficiency. Finally, the paper discusses wind power plant transmission solutions, with a focus on high-voltage direct-current topologies and controls.

17 WIND ENERGY↗

A Review on Protection Challenges on Transmission Lines Connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses. Utilities, university researchers, research institutes, and relay manufacturers have performed studies to investigate different aspects of high IBR penetration. Almost all studies support 1) creating international and national standards to regulate the IBRs, 2) revising engineering tools to address shortcomings, and 3) adjusting the protective relay settings to resolve protection problems. This paper summarizes the studies and research conducted in recent years to quantify the impact of IBR penetration on transmission line protection and to identify potential solutions to improve the dependability and reliability of grid protection systems.

14 SOLAR ENERGY↗

Spin State Modulation via Magnetic Fields in Fe Single Atom Catalysts for High-Performance Aqueous Zinc–Sulfur Batteries

Aqueous zinc–sulfur battery has garnered significant attention as a high-energy, low-cost, and safe energy storage system. However, the multielectron transfer kinetics of sulfur cathodes are relatively slow, presenting challenges such as limited sulfur utilization and lower discharge voltage, which significantly hinder their practical applications. Here, in this study, we explored a comprehensive design approach for high-performance, long-cycle aqueous zinc–sulfur batteries. The simultaneous introduction of ZnI 2 and Fe single atoms (Fe-SAs) as catalytically active agents decouples the redox reactions, effectively facilitating ZnS oxidation and S reduction separately. The application of an external magnetic field regulates the spin state of Fe-SAs, further enhancing their catalytic activity and electron transfer capability. Electrochemical tests demonstrate that the S@Fe-NC HS/ZnI 2 cathode assembled under a magnetic field exhibits excellent rate performance, achieving an impressive specific capacity of 1399 mAh g –1 at a high current density of 5 A g –1 and good cycling stability over 300 cycles, representing the highest reported high-current discharge capacity to date. This study provides a comprehensive design framework for optimizing zinc–sulfur (Zn–S) battery performance and elucidates the influence of magnetic field-induced spin state modulation on catalytic behavior.

36 MATERIALS SCIENCE↗

Control Design of Series-connected PV-powered Grid-forming Converters via Singular Perturbation

We report modular architectures that consist of several series-connected dc-ac converters have been a focal point of recent innovations in transformerless medium-voltage applications. In this paper, we consider an architecture consisting of dc-ac modules containing a quadruple active bridge dc-dc converter, which generates three floating dc links that feed grid-side dc-ac inverters. Practical implementation of such a converter module in PV systems requires a variety of controllers that collectively achieve maximum power point tracking, dc-link regulation, and ac-side power control. Design of such multi-loop systems is generally quite challenging due to the potential for destabilizing interactions among loops. Here we propose a design approach where singular perturbation theory is used to decompose the timescales at which each control loop operates and provides a systematic framework for parametric selection. Our approach also ensures system stability of multiple modules with identical controls connected in series across a grid. The paper concludes with experimental results of three 1000 W series-connected converter modules across a stiff grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Throughput In-Line Deposition of Silicon Oxide for Polycrystalline Silicon Passivating Contacts

Polycrystalline silicon passivating contacts rely on an ultrathin (1–2 nm) silicon oxide layer to minimize recombination at the wafer/oxide interface and regulate dopant diffusion. Traditionally formed by thermal or chemical oxidation, this oxide is herein replaced by silicon oxide deposited via aerosol impact-driven assembly (AIDA), enabling high wafer-per-hour throughput and precise thickness control. In this study, we show that AIDA coatings conformally cover planar or textured substrates and achieve a SiO x /poly-Si(n) structure with an implied open-circuit voltage (iV oc = 726 mV) and contact saturation current density (J 0 = 8.8 fA/cm 2 ). Furthermore, annealing AIDA SiO x films at elevated temperatures desorbs hydroxyl groups while the stoichiometry transitions toward SiO 2 , improving passivation quality. Together, these results highlight AIDA’s potential for scalable, high-throughput manufacturing of advanced passivating contacts, offering a cost-effective alternative to conventional low-pressure chemical vapor deposition and plasma-enhanced chemical vapor deposition-based silicon and oxide processes.

TOPcon↗

High-Voltage Sodium–Metal Batteries with Asymmetric Fluoroalkoxylated Organoborate Anion Chemistry

The high reactivity of sodium (Na) metal restricts its compatibility to ether-based electrolytes, while the poor oxidative stability of ethers precludes their coupling to high-voltage cathodes, fundamentally limiting the operating voltage and energy density of sodium–metal batteries (SMBs). We present here a coordination-asymmetry strategy to reconcile this thermodynamic mismatch by generating in situ an asymmetric fluoroalkoxylated organoborate anion, [FB(OCH(CF 3 ) 2 ) 3 ] − (BOF – ), via a Lewis acid–base adduct reaction in ether electrolyte. The asymmetric ligand architecture differentiates oxidative and fluorination pathways: oxidizable B–O moieties mediate controlled interfacial reconstruction, whereas the terminal B–F units supply fluorine for chemical passivation. This self-adaptive chemistry yields nanoscale, conformal, compositionally graded interphases: a boron-oxide/boron-oxycarbide-rich cathode-electrolyte interphase (CEI) that mitigates ether oxidation and a bilayered inorganic–organic solid–electrolyte interphase (SEI) that regulates Na deposition. The nanostructured interphases enable highly reversible Na plating/stripping with an average Coulombic efficiency (CE) of 99.98% and sustain stable 4.3 V operation of anode-free SMBs in oxidation-prone ether electrolytes. Furthermore, this work establishes asymmetric boron coordination as a molecular-level design principle for creating chemically adaptive interphases that overcome the redox asymmetry in energy-dense electrochemical systems.

Anions↗

All Hazards Approach to Grid Modernization

Resilience hazards for electric power systems are on the rise, exacerbated by both a rise in extreme weather events and manmade physical and cyber attacks. At the same time, grid modernization challenges plague the United States, covering everything from increased electrification and ambitious renewable energy targets to aging infrastructure and regulation that lags behind today’s challenges. This talk will cover an all-hazards risk based approach that addresses both rising resilience and grid modernization challenges. Examples of this approach taken for national laboratory research projects will be discussed, including a deep dive into a project that addressed black start, resynchronization, distributed control, and cybersecurity challenges for an operational microgrid up to sub-transmission voltages. As takeaways from this project are translated from demonstration scale to real-world exercises, key lessons are noted on the translation from research into practice and how this can inform risk-based research moving forward

17 WIND ENERGY↗

Molecular pathways for learning in the single-cell Stentor coeruleus

The single-cell Stentor coeruleus contracts in response to mechanical taps but habituates and learns to ignore the taps after repeated stimulation. Here, we explored the molecular changes that occur during the formation of this cellular memory in order to improve our understanding of non-synaptic learning. We impaired cellular protein synthesis with cycloheximide and puromycin and found that, contrary to the effects of such treatments on metazoa, these drugs accelerate habituation and prolong memory retention in Stentor . Exploratory proteomic and transcriptomic analyses identified candidate proteins and genes that changed over the course of habituation and response recovery, pointing toward the regulation of Stentor learning by calcium signaling and protein phosphorylation. Building on these results, we found that using RNA interference to knock down the calcium-binding, EF-hand domain-containing protein SteCoe_6763 accelerated habituation. Furthermore, increased extracellular calcium improved Stentor learning, while treatment with kinase and phosphatase inhibitors impaired learning. In particular, KN-93, a drug known to inhibit calcium/calmodulin-dependent kinase II and voltage-gated calcium channels, decreased both the rate and extent of habituation in Stentor , similar to its effects on learning in metazoa. We also discovered that habituation memory can be maintained in progeny following cell division. Taken together, these results suggest that response recovery in Stentor requires new protein synthesis and that memory formation involves the modification of delocalized mechanoreceptors by phosphorylation and calcium signaling. This is consistent with our previous model of Stentor learning, in which habituation occurs through the inactivation of cell-surface receptors.

CaMKII↗

Doping-modulated strain control of bifunctional electrocatalysis for rechargeable zinc–air batteries

Changes in the local atomic arrangement in a crystal caused by lattice-mismatch-induced strain can efficiently regulate the performance of electrocatalysts for zinc–air batteries (ZABs) in many manners, mainly due to modulated electronic structure configurations that affect the adsorption energies for oxygen-intermediates formed during oxygen reduction and evolution reactions (ORR and OER). However, the application of strain engineering in electrocatalysis has been limited by the strain relaxation caused by structural instability such as dissolution and destruction, leading to insufficient durability towards the ORR/OER. In this work, we propose a doping strategy to modulate the phase transition and formation of self-supported cobalt fluoride–sulfide (CoFS) nanoporous films using a low amount of copper (Cu) as a dopant. This well-defined Cu–CoFS heterostructure overcomes the obstacle of structural instability. Our study of the proposed Cu–CoFS also helps establish the structure–property relationship of strained electrocatalysts by unraveling the role of local strain in regulating the electronic structure of the catalyst. As a proof-of-concept, the Cu–CoFS electrocatalyst with doping-modulated strain exhibited superior onset potentials of 0.91 V and 1.49 V for the ORR and OER, respectively, surpassing commercial Pt/C@RuO 2 and benchmarking non-platinum group metal (non-PGM) catalysts. ZABs with the Cu–CoFS catalyst delivered excellent charge/discharge cycling performance with an extremely low voltage gap of 0.5 V at a current density of 10 mA cm –2 and successively 0.93 V at a high current density of 100 mA cm –2 and afforded an outstanding peak power density of 255 mW cm –2 .

25 ENERGY STORAGE↗

A Two-Step Restoration Scheme with DER Controllability for Resilient Distribution Systems

Modern distribution systems have increasing integration of distributed energy resources (DERs). A large number of distribution system DERs are interfaced through a power electronic converter. During grid contingency scenarios these resources have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid's restoration after an adverse event and hence enhancing resilience. In distribution systems, system restoration is an important problem, especially in face of high-impact low-frequency events. This paper proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in DERs for mitigating voltage problems. Simulation studies are performed on the IEEE-123 node feeder system to demonstrate the effectiveness of the proposed method for various cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Siloxane-functional small molecule acceptor for high-performance organic solar cells with 16.6% efficiency

As one of the simple but most effective molecular design strategies, side-chain engineering has been widely employed to modify the photoelectric properties of active layer materials for boosting the photovoltaic performance of organic solar cells (OSCs). In this work, a functionalized small molecule acceptor (SMA) named BTSi-4F with a bulky siloxane-terminated solubilizing group as side-chains, derived from a classical SMA of Y6, was designed and synthesized. The results demonstrate that the introduction of siloxane-functional terminated groups into SMA not only affects the optical absorption and molecular energy levels, but also regulates the miscibility between the polymer donor and SMA. Compared to the original Y6, BTSi-4F exhibits a better solubility, upshifted lowest unoccupied molecular orbital (LUMO) energy level, more ordered molecular packing, and higher electron-mobility. Matched with a wide bandgap polymer donor PM6, the chlorobenzene-processed OSCs based on PM6:BTSi-4F achieved a superior power conversion efficiency (PCE) of 16.6% with both high open-circuit voltage (V oc ) of 0.90 V and high fill factor (FF) of 0.77, while the devices based on PM6:Y6 obtained a much lower PCE of 13.0% with a V oc of 0.81 V and FF of 0.69 under the same conditions. This work offers a promising molecular design strategy of siloxane-terminated side chain engineering to develop high-performance SMAs for efficient OSCs.

14 SOLAR ENERGY↗