Search NASA⌕ Search

SEARCH · Search NASA

Results for “water heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Thermodynamic Analysis of Thermo-vacuum Clothes Drying Operation

Clothes drying accounts for a significant amount of energy consumed in residential and commercial sectors. A thermal vacuum clothes drying technology (TVCD) is proposed as an advanced clothes dryer which can significantly reduce the energy requirements by expediting the drying process. In the conventional convective clothes dryer, hot dry air is introduced into the drum which gets in direct contact to dry the clothes. This process is energy inefficient since the significant amount of heat and the water carried out with the exhaust stream are wasted. In contrast to the conventional convective drying technique, the drying mechanism of TVCD is through nucleate boiling at low temperature due to reduced vessel pressure. The process is not only efficient but also reduces the required time for drying. The objective of this paper is to develop a comprehensive thermodynamic model to predict the transient drying process of TVCD. The three-stage system model including the detail analysis of individual components is capable of simulating the variation of the water content in the textile under various operational conditions. The preliminary results show that the drying time of 3 lb textile from 70% to 2.5% in TVCD is approximately four times less than the time required in the conventional clothes dryer. Parametric studies are carried out to understand the effect of operation conditions and component geometry on the system performance. Energy consumption of the system is also analyzed.

Yang, Cheng-Min↗

Residential Home Decarbonization Using Advanced Micro-CHP

An efficient micro-combined heat and power (CHP) prototype was developed to provide heat and electricity for single-family homes and light commercial buildings. The unit can be installed independently at the point of energy consumption. Consequently, it enables cost-effectively and flexibly matching heat and electrical loads, simplifying distribution and installation processes, and recovering and storing waste heat as hot water. The analyzed results show that the micro-CHP using natural gas as fuel achieves 10.68%–32.80% CO2 reduction in the selected five home applications. The potential effect of H2 on decarbonization of these home was also evaluated, finding that the micro-CHP using a blended fuel with H2 and natural gas can further reduce CO2 emissions. However, the 50% CO2 reduction in the micro-CHP requires at least 70%–90% of H2 in the blend with natural gas. Overall, the micro-CHP technology demonstrates a solid potential to accelerate micro-CHP adoption in residential and light commercial markets, thereby promoting broader micro-CHP acceptance and use in the future for building decarbonization.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

Urban Versus Lake Impacts on Heat Stress and Its Disparities in a Shoreline City

Abstract Shoreline cities are influenced by both urban‐scale processes and land‐water interactions, with consequences on heat exposure and its disparities. Heat exposure studies over these cities have focused on air and skin temperature, even though moisture advection from water bodies can also modulate heat stress. Here, using an ensemble of model simulations covering Chicago, we find that Lake Michigan strongly reduces heat exposure (2.75°C reduction in maximum average air temperature in Chicago) and heat stress (maximum average wet bulb globe temperature reduced by 0.86°C) during the day, while urbanization enhances them at night (2.75 and 1.57°C increases in minimum average air and wet bulb globe temperature, respectively). We also demonstrate that urban and lake impacts on temperature (particularly skin temperature), including their extremes, and lake‐to‐land gradients, are stronger than the corresponding impacts on heat stress, partly due to humidity‐related feedback. Likewise, environmental disparities across community areas in Chicago seen for skin temperature are much higher (1.29°C increase for maximum average values per $10,000 higher median income per capita) than disparities in air temperature (0.50°C increase) and wet bulb globe temperature (0.23°C increase). The results call for consistent use of physiologically relevant heat exposure metrics to accurately capture the public health implications of urbanization.

54 ENVIRONMENTAL SCIENCES↗

Pool Boiling Reliability Tests and Degradation Mechanisms of Microporous Copper Inverse Opal (CuIOs) Structures: Preprint

The rising power density in electronic systems requires thermal management solutions that are both high-performing and reliable. Porous materials such as Copper Inverse Opals (CuIOs) have unique structural features, including high permeability and high thermal conductivity, to enhance pool boiling performance. However, there is little understanding of the degradation mechanism of such porous materials under pool boiling conditions. In this study, samples of 10-micrometer-thick CuIOs with 4.8-micrometer diameter, covering silicon substrate of area 11-mm by 11-mm, with various heated areas ranging from 2.5-mm by 2.5-mm to 10-mm by 10-mm, were tested in 100 degrees C deionized water at a constant heat flux of 110 watts per square cm for 3-7 days. The combined effect of erosion and corrosion caused structural degradation of the CuIOs. The directly heated area had the most severe degradation while the edge of the heater and the unheated area showed progressively less degradation, maintaining some CuIOs structure even after the 7-day reliability test. Among all the tested samples with various heater sizes, the 2.5-mm by 2.5-mm heater sample - in which the heater size was designed to be comparable to the water bubble characteristic length - had the largest critical heat flux (CHF) up to 300 watts per square cm with a superheat of approximately 13 degrees C. Additionally, CuIOs with a smaller heated area performed better in terms of reliability. This study offers preliminary insights into CuIOs degradation mechanisms, contributing to the development of more robust thermal management solutions. We expect that electroless plating of CuIOs with gold (Au), nickel (Ni), and atomic layer deposition of aluminum oxide in combination with appropriate application-specific coolants will further improve the reliability and lifetime of the CuIOs.

boiling-induced degradation↗

Pool Boiling Reliability Tests and Degradation Mechanisms of Microporous Copper Inverse Opal (CuIOs) Structures

The rising power density in electronic systems requires thermal management solutions that are both high-performing and reliable. Porous materials such as Copper Inverse Opal (CuIOs) have unique structural features, including high permeability and high thermal conductivity, to enhance pool boiling performance. However, there is little understanding of the degradation mechanism of such porous materials under pool boiling conditions. In this study, samples of 10 ..mu..m thick CuIOs with 4.8 ..mu..m diameter, covering silicon substrate of area 11 mm x 11 mm, with various heated areas ranging from 2.5 mm x 2.5 mm to 10 mm x 10 mm, were tested in 100 degrees C deionized water at a constant heat flux of 110 Wcm -2 for 3-to-7 days. The combined effect of erosion and corrosion caused structural degradation of the CuIOs. The directly heated area had the most severe degradation while the edge of the heater and the unheated area showed progressively less degradation, maintaining some CuIOs structure even after the 7-day reliability test. Among all the tested samples with various heater sizes, the 2.5 mm x 2.5 mm heater sample - in which the heater size was designed to be comparable to the water bubble characteristic length - had the largest critical heat flux (CHF) up to 300 Wcm -2 with a superheat ~ 13 degrees C. Additionally, CuIOs with a smaller heated area performed better in terms of reliability. This study offers preliminary insights into CuIOs degradation mechanisms, contributing to the development of more robust thermal management solutions. We expect that electroless plating of CuIOs with gold (Au), nickel (Ni), and atomic layer deposition (ALD) aluminum oxide (Al 2 O 3 ) in combination with appropriate application-specific coolants will further improve the reliability and lifetime of the CuIOs.

boiling-induced degradation↗

Large-scale molecular dynamics simulations of bubble collapse in water: Effects of system size, water model, and nitrogen

Molecular dynamics simulations in the microcanonical ensemble are performed to study the collapse of a bubble in liquid water using the single-site mW and the four-site TIP4P/2005 water models. To study system size effects, simulations for pure water systems are performed using periodically replicated simulation boxes with linear dimensions, L, ranging from 32 to 512 nm with the largest systems containing 8.7 × 10 6 and 4.5 × 10 9 molecules for the TIP4P/2005 and mW water models, respectively. The computationally more efficient mW water model allows us to reach converging behavior when the bubble dynamics results are plotted in reduced units, and the limiting behavior can be obtained through linear extrapolation in L –1 . Qualitative differences are observed between simulations with the mW and TIP4P/2005 water models, but they can be explained by the models’ differences in predicted viscosity and surface tension. Although bubble collapse occurs on time scales of only hundreds of picoseconds, the system sizes used here are sufficiently large to obtain bubble dynamics consistent with the Rayleigh–Plesset equation when using the models’ thermophysical properties as input. For the conditions explored here, extreme heating of the interfacial water molecules near the time of collapse is observed for the larger mW water systems (but the model underpredicts the viscosity), whereas heating is less pronounced for the TIP4P/2005 water systems because its larger viscosity contribution slows the collapse dynamics. The presence of nitrogen within the bubble only starts to affect bubble dynamics near the very end of the initial collapse, leading to an incomplete collapse and strong rebound for the mW water model. Although nitrogen is non-condensable at 300 K, it becomes highly compressed and reaches a liquid-like density near the collapse point. We find that the dissolution of nitrogen is much slower than the movement of the collapsing water front, and the re-expansion of the dense nitrogen droplet gives rise to bubble rebound. The incompatibility of the collapse and dissolution time scales should be considered for continuum-scale modeling of bubble dynamics. Finally, we also confirm that the diffusion coefficient for dissolved nitrogen is insensitive to pressure as the liquid transitions from a compressed to a stretched state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic energy system modeling using hybrid physics-based and machine learning encoder–decoder models

Three model configurations are presented for multi-step time series predictions of the heat absorbed by the water and steam in a thermal power plant. The models predict over horizons of 2, 4, and 6 steps into the future, where each step is a 5-minute increment. The evaluated models are a pure machine learning model, a novel hybrid machine learning and physics-based model, and the hybrid model with an incomplete dataset. The hybrid model deconstructs the machine learning into individual boiler heat absorption units: economizer, water wall, superheater, and reheater. Each configuration uses a gated recurrent unit (GRU) or a GRU-based encoder–decoder as the deep learning architecture. Mean squared error is used to evaluate the models compared to target values. The encoder–decoder architecture is over 11% more accurate than the GRU only models. The hybrid model with the incomplete dataset highlights the importance of the manipulated variables to the system. The hybrid model, compared to the pure machine learning model, is over 10% more accurate on average over 20 iterations of each model. Automatic differentiation is applied to the hybrid model to perform a local sensitivity analysis to identify the most impactful of the 72 manipulated variables on the heat absorbed in the boiler. The models and sensitivity analyses are used in a discussion about optimizing the thermal power plant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Warming and elevated CO 2 alter tamarack C fluxes, growth and mortality: evidence for heat stress-related C starvation in the absence of water stress

Climate warming is increasing the frequency of climate-induced tree mortality events. While drought combined with heat is considered the primary cause of this mortality, little is known about whether moderately high temperatures alone can induce mortality, or whether rising CO 2 would prevent mortality at high growth temperatures. In this study, we grew tamarack ( Larix laricina ) under ambient (400 p.p.m.) and elevated (750 p.p.m.) CO 2 concentrations combined with ambient, ambient +4 °C and ambient +8 °C growth temperatures to investigate whether high growth temperatures lead to carbon (C) limitations and mortality. Growth at +8 °C led to 40% mortality in the ambient CO 2 (8TAC) treatment, but no mortality in the elevated CO 2 treatment. Thermal acclimation of respiration led to similar leaf C balances across the warming treatments, despite a lack of photosynthetic acclimation. Photosynthesis was stimulated under elevated CO 2 , increasing seedling growth, but not leaf C concentrations. However, growth and foliar C concentrations were lowest in the +8 °C treatments, even with elevated CO 2 . Dying 8TAC seedlings had lower needle C concentrations and lower ratios of photosynthesis to respiration than healthy 8TAC seedlings, indicating that C limitations were likely the cause of seedling mortality under high growth temperatures.

54 ENVIRONMENTAL SCIENCES↗

Cloud water adjustments to aerosol perturbations are buffered by solar heating in non-precipitating marine stratocumuli

Abstract. Marine low-level clouds are key to the Earth's energy budget due to their expansive coverage over global oceans and their high reflectance of incoming solar radiation. Their responses to anthropogenic aerosol perturbations remain the largest source of uncertainty in estimating the anthropogenic radiative forcing of climate. A major challenge is the quantification of the cloud water response to aerosol perturbations. In particular, the presence of feedbacks through microphysical, dynamical, and thermodynamical pathways at various spatial and temporal scales could augment or weaken the response. Central to this problem is the temporal evolution in cloud adjustment, governed by entangled feedback mechanisms. We apply an innovative conditional Monte Carlo subsampling approach to a large ensemble of diurnal large-eddy simulation of non-precipitating marine stratocumulus to study the role of solar heating in governing the evolution in the relationship between droplet number and cloud water. We find a persistent negative trend in this relationship at night, confirming that the role of microphysically enhanced cloud-top entrainment. After sunrise, the evolution in this relationship appears buffered and converges to ∼-0.2 in the late afternoon. This buffering effect is attributed to a strong dependence of cloud-layer shortwave absorption on cloud liquid water path. These diurnal cycle characteristics further demonstrate a tight connection between cloud brightening potential and the relationship between cloud water and droplet number at sunrise, which has implications for the impact of the timing of advertent aerosol perturbations.

Zhang, Jianhao (ORCID:0000000169882935)↗

EXPERIMENTAL AND MODELLING ANALYSIS OF A LARGE-SCALE TWO-PHASE LOOP THERMOSYPHON

Liquid pumping requires large quantities of electrical energy, including about 7% of the energy of building heating, ventilation, and air conditioning (HVAC) systems. To replace pumped condenser-cooling tower water loops with a passive alternative system, we implemented a commercial-scale two-phase loop thermosyphon (TPLT). The unit consists of a 13 m riser integrated with a commercially available cooling tower and circulation water heater that simulates heat loads up to 25 kW. In addition to providing passive cooling capabilities, the cooling tower unit is also maintenance free, reliable, and can operate in both dry and wet modes. This study characterizes the performance (temperature difference between the evaporator and condenser) and the two-phase flow behavior of the loop under various refrigerant charges. Sight glasses installed throughout the loop are used to identify the operating flow regimes in the riser and downcomer. Over the range of operating conditions, we identified that there is an optimal refrigerant charge range for a specific heat load at which near-isothermal operation can be achieved. We further developed a model to predict the operating flow rate and gravitational height in the downcomer and compared it with the experimental data. The results show that the model agrees with the experimental data, in particular the threshold gravitational head height at which there will be subcooled liquid at the condenser exit, indicating that it can be used as a predictive tool for identifying the optimal loop charge for a given heat load.

Loop thermosyphon, passive two phase↗

Insights on Simulating Summer Warming of the Great Lakes: Understanding the Behavior of a Newly Developed Coupled Lake-Atmosphere Modeling System

The Laurentian Great Lakes are the world's largest freshwater system and regulate the climate of the Great Lakes region, which has been increasingly experiencing climatic, hydrological, and ecological changes. An accurate mechanistic representation of the Great Lakes thermal structure in Regional Climate Models (RCMs) is paramount to studying the climate of this region. Currently, RCMs have primarily represented the Great Lakes through coupled one-dimensional (1D) column lake models; this approach works well for small inland lakes but is unable to resolve the realistic hydrodynamics of the Great Lakes and leads to inaccurate representations of lake surface temperature (LST) that influence regional climate and weather patterns. This work overcomes this limitation by developing a fully two-way coupled modeling system using the Weather Research and Forecasting model and a three-dimensional (3D) hydrodynamic model. The coupled model system resolves the interactive physical processes between the atmosphere, lake, and surrounding watersheds; and validated against a range of observational data. The model is then used to investigate the potential impacts of lake-atmosphere coupling on the simulated summer LST of Lake Superior. By evaluating the difference between our two-way coupled modeling system and our observation-driven modeling system, we find that coupled-lake atmosphere dynamics can lead to a higher LST during June-September through higher net surface heat flux entering the lake in June and July and a lower net surface heat flux entering the lake in August and September. The unstratified water in June distributes the entering surface heat flux throughout the water column leading to a minor LST increase, while the stratified waters of July create a conducive thermal structure for the water surface to warm rapidly under the higher incoming surface heat flux. This research provides insight into the coupled modeling system behavior, which is critical for enhancing our predictive understanding of the Great Lakes climate system.

54 ENVIRONMENTAL SCIENCES↗

Coupled THM modeling of bentonite heating and hydration in tank tests with a new temperature-dependent water retention model

This study presents a coupled thermo-hydro-mechanical (THM) model for simulating the heating and hydration behavior of bentonite, a buffer material in deep geological repositories (DGRs). The model incorporates a new temperature-dependent soil water retention curve which captures the thermal-induced shift in water retention behavior. It also distinguishes between liquid and gas permeability, modeling intrinsic gas permeability as a function of accessible porosity to improve vapor transport and desaturation predictions. The model was validated against two large-scale tank tests, demonstrating good agreement with measured temperature, relative humidity, and water inflow data. It revealed a complex porosity evolution driven by thermal expansion, vapor movement, vapor condensation, and hydration-induced swelling during heating and hydration processes. The simulation results also suggest that the permeability of the hydration layer plays a critical role in controlling water intake. Clogging of this layer can significantly reduce the volume of water inflow during the hydration phase. Furthermore, while the model effectively captures key THM behavior, further development of the mechanical constitutive law is required to account for possible thermo-elasto-plastic volume changes and microstructural effects. Overall, the model provides a robust tool for evaluating the evolution of bentonite-based barrier material in DGRs.

Guo, Guanlong [Lawrence Berkeley National Laborato↗

Coupling subsurface and above-surface models for optimizing the design of borefields and district heating and cooling systems in the presence of varying water-table depth. In: Proceedings, 46th Workshop on Geothermal Reservoir Engineering

Dynamic energy simulation is important for the design and sizing of district heating and cooling systems with geothermal heat exchange. Current modeling approaches in building and district energy simulation tools typically consider heat conduction through the ground between boreholes, without flow of groundwater. On the other hand, detailed simulation tools for subsurface heat and mass transfer exist, but these fall short in simulating above-surface energy systems. To support the design and operation of such systems, we have developed a coupled model including a software package for building and district energy simulation, and software for detailed heat and mass transfer in the ground. For the first, we use the open-source Modelica Buildings Library, which includes dynamic simulation models for building and district energy and control systems. For the heat and mass transfer in the soil, we use the TOUGH simulator. TOUGH can model heat and multi-phase, multi-component mass transport for a variety of fluid systems, as well as chemical reactions, in fractured porous media. In previous work, we described the coupling of these software packages, including how time-dependent boundary conditions for the borehole walls are synchronized for use in Modelica and TOUGH. We verified that the coupled Modelica/TOUGH code produced consistent results with the original Modelica code for an idealized problem in which heat transfer was purely by conduction in a uniform geologic medium. Here, we examine less idealized problems for which TOUGH’s advanced capabilities for modeling fluid flow are required. The first problem has a shallow vadose zone, and the second problem has a thicker vadose zone with a water-table depth that varies in time, which requires a fine vertical grid discretization for the TOUGH model.

Doughtry, Christine↗

Analysis of Design Alternatives of Actively Cooled RF Window for MPEX

The Materials Plasma Exposure eXperiment (MPEX) has been designed as a linear plasma divertor simulator in order to address plasma material interaction (PMI) science for next-generation fusion devices. It will have the capability to test neutron irradiated samples with plasma fluxes of greater than 10 24 m -2 s -1 . It is expected to operate steady state for up to 10 6 s to consider PMI affects through reactor end of life. The conceptual design of MPEX was completed in 2019, with preliminary design having begun in 2020. The plasma source for MPEX is a helicon antenna, where the energized helical antenna sits outside of the vacuum in order to minimize impurities in the plasma. It is expected to receive up to 200 kW of continuous power, and so the antenna and the window must be actively cooled. The water-cooled copper antenna has been operated at full power on the Proto-MPEX device (which is a test facility to demonstrate the plasma source and heating systems). The water-cooled window, however, is a novel component that must meet numerous competing requirements. It requires a low dielectric loss to allow the Radio Frequency (RF) power to create the plasma within the vacuum boundary. It must be structurally robust to handle the significant heat flux from the plasma and any heat from dielectric coupling. It must be compatible with the coolant (preferably water). It requires a vacuum seal that minimizes impurities into the plasma and does not compromise the structural integrity of the window. Two window designs have been tested. Results from these tests, where temperatures are measured and heat fluxes inferred from infrared camera data, have been correlated with thermal-structural simulations. When these simulations are extrapolated to the full power steady-state heat fluxes that are expected in MPEX, the designs do not appear to have the necessary structural robustness. This study explores design alternatives for the MPEX helicon antenna window, presents analysis results for several of the alternatives, and shows a viable solution that satisfies the requirements for MPEX operation.

Tipton Jr, Joseph↗

Advanced metal hydride heat transfer system utilizing an electrochemical hydrogen compressor

An electrochemical heat transfer device for a hot water tank utilizes an electrochemical hydrogen compressor to pump hydrogen into and out of a tank having a metal hydride forming alloy therein. The absorption of hydrogen by the metal hydride forming alloy is exothermic, produces heat, and the desorption of the hydrogen from the metal hydride forming alloy is endothermic and draws heat in. An electrochemical hydrogen compressor may be configured between to tanks and pump hydrogen back and forth to form a heat transfer device, such as a hot water heater. A heat transfer device may be coupled with the tank or may comprise the outer surface of the tank to transfer heat to an object or to the surroundings. A closed loop may be configured having two tanks and one or two electrochemical hydrogen compressors to pump the hydrogen in a loop around the system.

Bahar, Bamdad↗

Community Geothermal: Mechanical, Electrical, and Plumbing Design Report and Drawings - Wallingford, CT

Included here are the mechanical, electrical, and plumbing design report and drawings for the proposed community geothermal system at an affordable housing complex in Wallingford, Connecticut. The report and drawings were developed by LN Consulting, in partnership with the University of Connecticut, which completed the energy modeling that formed the basis of the design work. The drawings can be used as a basis for a Request for Proposals to procure entities to complete construction-ready design documents.

15 GEOTHERMAL ENERGY↗