Flaring Stars in a Non-targeted mm-wave Survey with SPT-3G

We present a flare star catalog from four years of non-targeted millimeter-wave survey data from the South Pole Telescope (SPT). The data were taken with the SPT-3G camera and cover a 1500-square-degree region of the sky from $20^{h}40^{m}0^{s}$ to $3^{h}20^{m}0^{s}$ in right ascension and $-42^{\circ}$ to $-70^{\circ}$ in declination. This region was observed on a nearly daily cadence from 2019-2022 and chosen to avoid the plane of the galaxy. A short-duration transient search of this survey yields 111 flaring events from 66 stars, increasing the number of both flaring events and detected flare stars by an order of magnitude from the previous SPT-3G data release. We provide cross-matching to Gaia DR3, as well as matches to X-ray point sources found in the second ROSAT all-sky survey. We have detected flaring stars across the main sequence, from early-type A stars to M dwarfs, as well as a large population of evolved stars. These stars are mostly nearby, spanning 10 to 1000 parsecs in distance. Most of the flare spectral indices are constant or gently rising as a function of frequency at 95/150/220 GHz. The timescale of these events can range from minutes to hours, and the peak $\nu L_{\nu}$ luminosities range from $10^{27}$ to $10^{31}$ erg s$^{-1}$ in the SPT-3G frequency bands.

79 ASTRONOMY AND ASTROPHYSICS↗

Utah FORGE: Slide-Hold-Slide Experiments on Gneiss at Increased Temperature

Included are data from triaxial, single-inclined-fracture friction experiments. The experiments were performed with slide-hold-slide protocol on Utah FORGE gneiss at increased temperature. With a ~10 MPa normal stress, temperatures vary between experiments from room temperature up to 163 Celsius. Hold times vary during experiment from ~10^1 to ~10^5 seconds. Measured are the frictional response upon reactivation after a hold period, active acoustic data (P-wave velocity and amplitude) and passive acoustic data (acoustic emission occurrence and amplitude). There are two types of datafiles: (1) Datafiles containing the friction data, including the temperature and the active acoustic data measured during the experiment (AEXX_Gneiss_Vp_mixref4). The underscore _Vp means that it includes the Vp or P-wave velocity data, with _mixref meaning that we use a mixed reference point for calculating the P-wave velocity. And (2) the datafiles containing the passive acoustics data, a catalog of the acoustic emissions (AE's) measured during the experiment (AEcatalog_AEXX_runX), where AEXX matches the experiment number and runX denotes which part of the experiment the data was collected, matching the times where active acoustic data was collected. AE catalogs are split in two parts when the file size exceeds 1 GB to aid download/opening times.

15 GEOTHERMAL ENERGY↗

Analysis on Evaluations of Monterey Bay Aquarium Research Institute’s Wave Energy Converter’s Field Data Using WEC-Sim and Gazebo: A Simulation Tool Comparison

Although many studies have validated wave energy converter (WEC) numerical models against scaled prototype experimental data, there remains a notable lack of validation using data from full-scale deployed WECs. This paper compares two numerical models of Monterey Bay Aquarium Research Institute’s Wave Energy Converter (MBARI-WEC), a two-body point absorber with an electro-hydraulic power take-off system (PTO). The models are implemented in WEC-Sim/Simscape and Gazebo Simulator. A statistical analysis of the models was performed, and field results were obtained to compare the models’ accuracy in predicting the RMS piston velocity, RMS motor speed, and mean electric power compared to field data for 56 observations across varying sea states. The Gazebo model demonstrated a closer agreement across all three parameters for a majority of the observations. When compared to the field data, the Gazebo and WEC-Sim models exhibited average mean electric power overestimations of 13% and 22%, respectively.

16 TIDAL AND WAVE POWER↗

Data synthesis and display programs for wave distribution function analysis

At the National Space Science Data Center (NSSDC) software was written to synthesize and display artificial data for use in developing the methodology of wave distribution analysis. The software comprises two separate interactive programs, one for data synthesis and the other for data display.

Storey, L. R. O.↗

On the Propagation and Interaction of Spherical Blast Waves

The characteristics and the scaling laws of isolated spherical blast waves have been briefly reviewed. Both self-similar solutions and numerical solutions of isolated blast waves are discussed. Blast profiles in the near-field (strong shock region) and the far-field (weak shock region) are examined. Particular attention is directed at the blast overpressure and shock propagating speed. Consideration is also given to the interaction of spherical blast waves. Test data for the propagation and interaction of spherical blast waves emanating from explosives placed in the vicinity of a solid propellant stack are presented. These data are discussed with regard to the scaling laws concerning the decay of blast overpressure.

Kandula, Max↗

Low-pressure overdriven experiments in PBX-9502

Symmetric impact experiments were performed on PBX 9502 to obtain Hugoniot data in the low-pressure, overdriven regime. An explosive plane wave lens (P300 with comp-B booster) was used to launch an aluminum flyer plate (4 to 4.5 km/s) into an aluminum target backed by the PBX 9502 samples and a LiF window. Photonic Doppler velocimetry (PDV) was used to obtain the shock transit time through the PBX 9502 samples and wave profile data at the PBX 9502/LiF interface. Past experimental result in the overdriven regime, utilizing a rotating mirror streak camera, revealed a well-defined high-pressure Hugoniot. In contrast, the low-pressure (overdriven) data exhibited significant scatter likely due to non-steady wave effects associated with the thin PBX 9502 samples (3-5 mm) used in the experiments. The objective of the current work was to obtain Hugoniot data in the low-pressure, overdriven regime for PBX 9502 using recently developed diagnostics along with thicker samples (5-10mm) to decrease the uncertainty and scatter in the Hugoniot data.

36 MATERIALS SCIENCE↗

The φ-relation and a simple method to predict how many data points are needed for relevant steady-state detection

Steady–state detection is of vital importance for experiments and simulations in chemical engineering, as well as also other fields of science, engineering, and finance—particularly when the full timescale of interest cannot be measured or simulated. We present a breakthrough for estimating the number of data points required before successful steady–state detection is feasible. Using an initial window of data, the method enables predicting the prerequisites for steady state detection (ppSSD), given as a number of data points. The method is shown to be accurate for data with realistic distributions (uniform, normal, and sine–wave), and data from actual kinetic Monte Carlo simulations. In conclusion, users need only to use the algebraic equations derived and provided in this work to estimate the required number of data points for relevant steady–state detection.

42 ENGINEERING↗

Singular value decomposition applied to compact binary coalescence gravitational-wave signals

We investigate the application of the singular value decomposition to compact-binary, gravitational-wave data-analysis. We find that the truncated singular value decomposition reduces the number of filters required to analyze a given region of parameter space of compact-binary coalescence waveforms by an order of magnitude with high reconstruction accuracy. We also compute an analytic expression for the expected signal loss due to the singular value decomposition truncation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compression and R-wave detection of ECG/VCG data

Application of information theory to eliminate redundant part of electrocardiogram or vectorcardiogram is described. Operation of medical equipment to obtain three dimensional study of patient is discussed. Use of fast Fourier transform to accomplish data compression is explained.

Hayden, W. L.↗

Study of low frequency hydromagnetic waves using ATS-1 data

An analysis was made of ATS-1 data to determine at what point in the magnetic storm recovery phase are oscillations most likely to begin. The catalog of hourly values of equatorial Dst was used to determine the time of main phase decrease, and a catalog of oscillations from January to May 1968 to determine onset time as observed by ATS-1. For each oscillation event at ATS-1, the nearest prior main phase decrease with a magnitude of at least -35 gamma was determined, and the time difference between the onset of the event at ATS-1 and the time of main phase decrease was measured. The resulting data indicate that the most probable time to observe onset of transverse oscillations is within 24 hours after the main phase decrease.

Cummings, W. D.↗

Study of low frequency hydromagnetic waves using ATS-1 data

Low frequency oscillations of the magnetic field at ATS-1 were analyzed for the 25 month data interval, Dec., 1966 through 1968. Irregular oscillations and those associated with magnetic storms were excluded from the analysis. Of the 222 events identified, 170 were found to be oscillating predominantly transverse to the background magnetic field. The oscillations were observed to occur most frequently in the early afternoon hours. They also seemed to occur more frequently during Dec., Jan., and Feb. than at any other time of the year. During a given event, the frequency was fairly constant. The event duration varied between a minimum of 10 min. and a maximum of 14 hrs and 26 min. During a given event the amplitude varied.